key: cord-1056571-9a6x9g60 authors: Bagate, François; Masi, Paul; d’Humières, Thomas; Al-Assaad, Lara; Chakra, Laure Abou; Razazi, Keyvan; de Prost, Nicolas; Carteaux, Guillaume; Derumeaux, Genevieve; Mekontso Dessap, Armand title: Advanced echocardiographic phenotyping of critically ill patients with coronavirus-19 sepsis: a prospective cohort study date: 2021-01-20 journal: J Intensive Care DOI: 10.1186/s40560-020-00516-6 sha: 66ca6773f705afd13439c1222d74855da36b1662 doc_id: 1056571 cord_uid: 9a6x9g60 BACKGROUND: Sepsis is characterized by various hemodynamic alterations which could happen concomitantly in the heart, pulmonary and systemic circulations. A comprehensive demonstration of their interactions in the clinical setting of COVID-19 sepsis is lacking. This study aimed at evaluating the feasibility, clinical implications, and physiological coherence of the various indices of hemodynamic function and acute myocardial injury (AMI) in COVID-19 sepsis. METHODS: Hemodynamic and echocardiographic data of septic critically ill COVID-19 patients were prospectively recorded. A dozen hemodynamic indices exploring contractility and loading conditions were assessed. Several cardiac biomarkers were measured, and AMI was considered if serum concentration of high-sensitive troponin T (hs-TNT) was above the 99th percentile, upper reference. RESULTS: Sixty-seven patients were assessed (55 males), with a median age of 61 [50–70] years. Overall, the feasibility of echocardiographic parameters was very good, ranging from 93 to 100%. Hierarchical clustering method identified four coherent clusters involving cardiac preload, left ventricle (LV) contractility, LV afterload, and right ventricle (RV) function. LV contractility indices were not associated with preload indices, but some of them were positively correlated with RV function parameters and negatively correlated with a single LV afterload parameter. In most cases (n = 36, 54%), echocardiography results prompted therapeutic changes. Mortality was not influenced by the echocardiographic variables in multivariable analysis. Cardiac biomarkers’ concentrations were most often increased with high incidence of AMI reaching 72%. hs-TNT was associated with mortality and inversely correlated with most of LV and RV contractility indices. CONCLUSIONS: In this comprehensive hemodynamic evaluation in critically ill COVID-19 septic patients, we identified four homogeneous and coherent clusters with a good feasibility. AMI was common and associated with alteration of LV and RV functions. Echocardiographic assessment had a clinical impact on patient management in most cases. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40560-020-00516-6. The pandemic of coronavirus disease 2019 caused by the novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) represents the greatest global public health crisis of the last decades. Approximatively, up to 40% of hospitalized patients develop severe pneumonia with sepsis requiring intensive care unit (ICU) admission [1] . Sepsis is characterized by various hemodynamic alterations like hypovolemia, systolic and diastolic cardiac dysfunction, and vasoplegia [2] . In sepsis of pulmonary origin (as it is the case with COVID- 19) , pulmonary circulatory dysfunction (PCD) and mechanical ventilation may favor right ventricle (RV) dysfunction and acute cor pulmonale (ACP) [3] . Multiple alterations may occur in the same patient and give rise to complex interactions. For instance, the function of one ventricle may influence that of the other via the ventricular interdependence phenomenon [4] . Additionally, the loading conditions may affect left ventricle (LV) systolic [2, 5] and diastolic [6] functions. However, a clinical comprehensive demonstration of these interactions in COVID-19 patients is missing. Systemic [7] and pulmonary [8] vascular endothelial cell infection could accentuate the effect of loading disturbances in COVID-19. Direct cardiac involvement (e.g., myocarditis) has been suggested as a particular feature of COVID-19 [9] . However, the physiological markers of myocardial injury in COVID- 19 have been poorly studied. In recent years, new or revisited echocardiographic tools (speckle tracking and tissue Doppler imaging) and parameters (LV end-systolic maximal elastance and ventricular-arterial coupling) have been used to scrutinize cardiac functions [2] . The feasibility, clinical significance, and physiological coherence of these different indices have not been assessed in COVID-19 sepsis. The aims of the present study were as follows: (i) first, to assess, in COVID-19 patients, the feasibility, clinical implications, and physiological coherence of the various indices of cardiac function in evaluating hemodynamics in sepsis; (ii) second, to assess the physiological correlates of acute myocardial injury in COVID-19 sepsis. We conducted a prospective observational monocenter study on all patients diagnosed with RT-PCR-confirmed SARS-CoV-2 sepsis (Sepsis 3 definition [10] ) and consecutively admitted to the medical ICU of Henri Mondor Hospital, Créteil, France, between March 8 and April 26, 2020 . The study was approved by the institutional ethical committee of the French Intensive Care Society as a component of standard care, and patient consent was waived. Written and oral information about the study was given to the families. Case severity was evaluated by Simplified Acute Physiology Score II (SAPS II) for acute illness at ICU admission and by Sequential Organ Failure Assessment (SOFA) score for organ dysfunction in sepsis. For patients in shock, norepinephrine was given as the first-choice vasopressor therapy (targeting a mean arterial pressure of 65 mmHg or more). The patients were followed up until day 28. Acute myocardial injury (AMI) was diagnosed if serum concentration of high-sensitive troponin T (hs-TNT) surpassed the 99th percentile, upper reference level [11, 12] , i.e., hs-TNT > 14 ng/L. We also measured blood concentrations of N-terminal pro b-type natriuretic peptide (NT-proBNP) and creatinine phosphokinase (CPK). Serum hs-TNT was measured using electrochemiluminescence immunoassays (Cobas e, Roche Diagnostics GmbH, Mannheim, Germany). Serum NT-proBNP levels were measured by electrochemiluminescence (Cobas 6000, Roche Diagnostics GmbH, Mannheim, Germany), and creatinine phosphokinase by Roche/Hitachi Cobas C systems (Roche Diagnostics GmbH, Mannheim, Germany). To evaluate cardiac function, transthoracic echocardiography (TTE) was performed within 72 h of ICU admission by trained operators (competent in advanced critical care echocardiography) using an S7 or E9 ultrasound system (GEMS, Buc, France). All echocardiography tests were carried out in strict respect to current guidelines for care of COVID-19 patients [13] . We used a standard procedure to assess LV and RV sizes, filling, function, and output, as detailed in Additional file 1. All measurements taken for each examination were averaged over a minimum of three cardiac cycles (five to ten in case of non-sinus rhythm). LV hypertrophy and dilatation were defined as per the 2015 update of the American Society of Echocardiography, and the European Association of Cardiovascular Imaging guidelines, using ventricular mass and volume, respectively [14] . Apical long-axis (four-and two-chamber) clips obtained with a frame rate ≥ 50 Hz underwent on-line speckle tracking analyses conducted by two trained operators on the semi-automated EchoPAC package (GEMS, Buc, France) (see Additional file 1). LV preload was assessed using the maximal diameter of inferior vena cava (IVC) and estimates of LV filling pressures (E/A and E/e′ ratios) on pulsed-wave Doppler and tissue Doppler upon measuring, for the former early (E) and late (A), and for the latter early (e′) diastolic wave velocity at the lateral mitral valve annulus. LV afterload was assessed using invasively measured diastolic arterial pressure (DAP), systemic vascular resistance (SVR), and end-systolic arterial elastance (AE) (see Additional file 1 for more detail). LV systolic function assessment was based on the following indices: LV ejection fraction (LVEF) obtained by two-dimensional echocardiography, peak systolic wave at the lateral mitral valve annulus (sm) obtained by tissue Doppler imaging [10] , LV global longitudinal peak systolic strain (AS) by speckle tracking imaging, LV end-systolic maximal elastance (ME, see ES), and ventricular-arterial coupling (VAC, see ES), which is the ratio of LV end-systolic maximal elastance and end-systolic arterial elastance as previously described [2] . RV systolic function assessment relied on tricuspid annulus plane systolic excursion (TAPSE) and on tissue Doppler peak systolic wave at tricuspid lateral annulus (st). Patients were also stratified into three groups based on the degree of PCD, as previously described [3] and defined by the following: no dysfunction (group 0: pulmonary artery systolic pressure ≤ 40 mmHg with normal RV size and normal interventricular septum kinetics), moderate dysfunction (group 1: pulmonary artery systolic pressure > 40 mmHg or having dilated RV or paradoxical motion of interventricular septum, but without cor pulmonale), and severe dysfunction (group 2: cor pulmonale, defined as septal dyskinesia with dilated RV (end-diastolic RV/LV surface ratio > 0.6)). Data were analyzed using IBM SPSS Statistics for Windows (version 24.0, IBM Corp, Armonk, NY) and R 3.2.5 (The R Foundation for Statistical Computing, Vienna, Austria). Continuous data were expressed as medians [25th-75th centiles] unless otherwise specified and were compared using the Mann-Whitney test. Categorical variables, expressed as percentages, were evaluated using the chi-square or Fisher exact test. The two aims of our study were set primarily to test the feasibility of various indices of cardiac function, and to assess their physiological coherence using hierarchical clustering; this method builds homogeneous clusters based on dissimilarities or distances between cases, then proceeds iteratively to join the most similar cases. Within the same objective, we analyzed the impact of loading conditions on cardiac contractility by using bivariate correlations that were further summarized in a correlation matrix (corrplot package within R environment). Correlations were tested using Spearman's method with Benjamini-Hochberg correction to control the false discovery rate at 0.05 level. Secondly, we built a focused principal component analysis (FPCA; "psy" package, R 3.2.2, the R Foundation for Statistical Computing, Vienna, Austria) based on AMI as the dependent variable with simple graphical display of correlation structures of echocardiographic variables. Two-tailed p values < 0.05 were considered significant. Patients' characteristics, feasibility, and safety of echocardiography Patients' characteristics are provided in Table 1 . The study enrolled 67 patients (55 men and 12 women) of a median age of 61 [50-70] years. Most patients were males (n = 55, 82%) with cardiovascular risk factors like hypertension (n = 36, 54%) and diabetes (n = 24, 36%). Many patients were on long-term cardiovascular medications before hospital admission, including betablockers (n = 15, 22%), statins (n = 14, 21%), aspirin (n = 13, 19%), angiotensin-converting enzyme inhibitors (n = 13, 19%), angiotensin 2 receptor antagonists (n = 11, 16%), and furosemide (n = 6, 9%). Echocardiography examinations were performed a median of 1 [1-3] day after ICU admission and lasted a median of 21 [15] [16] [17] [18] [19] [20] [21] [22] [23] [24] min/exam (not counting preparation and cleaning time). When echocardiography was ordered, 60 (90%) patients required vasopressor infusion and 66 (99%) had invasive mechanical ventilation. Overall, the feasibility of measuring echocardiographic parameters was very good, ranging from 93 to 100% (Fig. 1 ). Concerning the five sonographers who conducted echocardiography, none were infected by SARS-CoV-2, and their serum serological tests for COVID-19 were all negative 1 month after the end of the study. Twenty-one (31%) patients had at least one feature of structural cardiopathy. Briefly, seven had chronic LV hypokinesia (LVEF < 45%), ten had dilated LV, seven had concentric hypertrophy, one had eccentric hypertrophy, and one had significant heart valve disease. In addition, chronic arterial hypertension and chronic atrial fibrillation were present in 36 (54%) and 6 (9%) patients, respectively. Hierarchical clustering of echocardiographic parameters identified four coherent clusters covering the following physiological pathways: LV contractility, RV function, LV afterload, and cardiac preload (Fig. 2a) . In the correlation matrix (Fig. 2b) , some LV contractility indices were positively correlated with RV function parameters and negatively correlated with a single LV afterload parameter, while no association with cardiac preload was found. The echocardiographic assessment modified our therapeutic approach as follows: optimized ventilator settings when patent foramen ovale or acute cor pulmonale were detected, by testing a decrease in PEEP for instance; fluid Figure S1 ). This association between E/A and mortality did not persist in the logistic regression after adjustment on age (OR 0.22, 95% confidence interval 0.03-1.13, p = 0.07, Table S3 ). Cardiac biomarkers' concentrations were higher than normal in the majority of patients (Table 1) , and AMI was detected in 47 patients (72%). The blood The main findings of this study were as follows: (i) bedside focused echocardiographic evaluation of critically ill patients with COVID-19 sepsis was feasible, safe, and incurred therapeutic changes in more than half of them; (ii) echocardiographic indices showed physiological coherence in this population where four coherent hemodynamic clusters were identified, of which two were positively correlated (LV contractility and RV function) and two others were inversely correlated (LV contractility and LV afterload); and (iii) AMI was common and inversely correlated with LV and RV contractility parameters. The high feasibility, safety, and clinical implications of echocardiography in COVID-19 septic patients suggest its usefulness in this setting as in other forms of sepsis. The feasibility of most echocardiography parameters, including strain, outweighed that previously reported, by our laboratory and others, in critically ill septic patients few years ago [2, 15] . Although strain measurement is angle-independent, less subjective than other computergenerated measurements, and very sensitive to detect altered contractility, its assessment requires high frame rate and adequate image quality [16] . The rapid technological evolution in echocardiography hardware (e.g., probe quality) and software (e.g., better recognition of LV walls) could explain our results. Furthermore, all echocardiography tests were performed by expert operators, who routinely use advanced echocardiography tools (including strain) in daily practice. In a, the parameters were reordered using computerized hierarchical clustering with the corrplot package of R statistical environment. Hierarchical clustering is a statistical method for finding comparatively homogeneous clusters of cases based on measured characteristics. The analysis starts with each case as a separate cluster (i.e., there are as many clusters as cases), and then combines the clusters sequentially, reducing the number of clusters at each step. The clustering method uses the dissimilarities between objects. The algorithm uses a set of dissimilarities or distances between cases when constructing the clusters and proceeds iteratively to join the most similar cases. Distances between clusters were recomputed by the Lance-Williams dissimilarity update formula according to the complete linkage method. In b, the four big squares drawn in the chart are based on the results of hierarchical clustering and each contains the members of a cluster (LV afterload cluster in the upper-left corner, cardiac preload cluster in the middle upper-left, LV contractility cluster in the middle lower-right, and RV function cluster in the lowerright corner). Numbers and the blue-white-red color spectrum denote the Spearman correlation coefficients (with Benjamini-Hochberg correction to control the false discovery rate at 0.05 level); positive correlations are represented in a blue scale; negative correlations are in a red scale. The surface areas of the colored pixels and their color intensity show the absolute value of corresponding correlation coefficients; non-significant coefficients are left blank. There was a strong correlation between most indices within the LV contractility cluster (blue pixels in the middle lowerright cluster) and within the LV afterload cluster (blue pixels in the upper-left cluster). In addition, some LV contractility indices were negatively correlated with an afterload parameter (red pixels above and to the left of the middle lower-right cluster), and positively correlated with RV function indices (blue pixels below and to the right of the middle lower-right cluster), but not with preload indices. IVC, maximal diameter of inferior vena cava in mm; EA, ratio of early to late diastolic wave velocity at the mitral valve; Ee, ratio of early pulsed-wave Doppler to early tissue Doppler diastolic wave velocity at the lateral mitral valve annulus; EF, LV ejection fraction in %; AS, absolute values of global LV longitudinal peak systolic strain in %; sm, tissue Doppler peak systolic wave at lateral mitral annulus in cm s −1 ; VAC, ventricular-arterial coupling; ME, LV end-systolic maximal elastance in mmHg mL −1 ; AE, end-systolic arterial elastance in mmHg mL −1 ; SVR, systemic vascular resistance in mmHg L −1 min; DAP, diastolic arterial pressure in mmHg; PCD, pulmonary circulatory dysfunction; TAPSE, tricuspid annulus plane systolic excursion in mm; st, tissue Doppler peak systolic wave at tricuspid lateral annulus in cm s −1 In order to minimize the risk of infection spread among healthcare professionals [17] , some authors have recommended to keep the use of echocardiography to a minimum in COVID-19 patients [18, 19] . On the other hand, echocardiography could help clinicians manage COVID-19 sepsis-related hemodynamic alterations. Studies have reported that COVID-19 is associated with specific cardiovascular manifestations, like thromboembolic complications [20] and cardiac injury [21] . The duration of examination (median of 21 min, not including installation or disinfection time) was close to that reported in other critically ill patients [22] . None of the operators in our series got infected, which proves that the recommended measures for the protection of healthcare workers taking care of COVID-19 patients are efficient and that most routine investigations can be safely performed. Most of the echocardiography examinations were followed by therapeutic changes, e.g., administering vasopressors, fluid loading, change of respiratory settings, and use of anticoagulant or thrombolysis, an incentive for a wider indication of echocardiography despite the theoretical risk of infection. A recent large global survey found a comparable impact of echocardiography on management of COVID-19 patients [23] . We identified four coherent and homogeneous clusters involving LV contractility, RV function, LV afterload, and cardiac preload. These findings are consistent with results from previous studies highlighting the physiological coherence of echocardiographic parameters in critically ill patients with sepsis and/or acute respiratory distress syndrome [2, 24] . The absence of correlation between contractility and preload indices matches what previous studies found in human sepsis [2] and is coherent with the fact that echocardiography tests were performed in patients after the initiation of resuscitation and receiving variable amounts of fluids. The association between LV contractility and RV function is also compatible with previous reports results and may be explained by the physiological biventricular interdependence [25] . The inverse correlation between LV contractility and LV afterload is consistent with previous reports, highlighting the role of afterload on contractility indices in sepsis [2] . Overall, our results suggest that COVID-19 induces a myriad of hemodynamic alterations similar to those observed in other forms of sepsis. Several studies in COVID-19 with or without critical illness have suggested an association between markers of RV/LV dysfunction and COVID-19 related death [26, 27] . In our work, no association was found between 28day mortality and echocardiographic variables, except for lower E/A values in non-survivors. This finding may suggest a detrimental role of diastolic function as previously reported in other forms of sepsis [28] . However, this association did not persist after adjustment on age, a well-known strong prognostic factor in COVID-19. E/A is altered with aging and in case of chronic arterial hypertension [29] , two common features in severe forms of COVID-19. As expected and demonstrated in other studies [9, 30] , acute myocardial damage was associated with mortality. The prevalence of AMI in our cohort was similar to that in a larger echocardiographic study [30] . Many reports have documented direct myocardial injury incurred by coronavirus-19 [31] . The association between myocardial injury and indices of LV and RV function in our study is in accordance with this hypothesis. The strengths of our study rely on the detailed phenotyping using advanced echocardiography, and the exploration of a majority of patients with critical COVID-19, unlike previous studies on the topic [23, 32] . Our study has some limitations. First, the design was monocentric with a limited number of patients (n = 67); for this reason, we were not able to carry out robust multivariable analyses and could only cluster echoparameters, but not patient groups. Some patients were assessed under ECMO, which may alter hemodynamics, but we aimed at exploring all septic critically ill COVID-19 patients, including the most severe. Another important limitation is that transthoracic (TTE) rather than transesophageal echocardiography (TEE) was used, knowing that the latter may outperform TTE for some explorations [33] . The choice of routine TTE was imposed by the fear of specific contamination risks associated with esophageal intubation [34] and by the constraints related to probe sterilization in the context of pandemics. Whether the routine use of TEE may have a similar safety warrants further research. Third, not all patients in the cohort could be assessed at the very early stage. Indeed, our ICU is a tertiary center, and some patients were referred from another ICU. Finally, due to the workload, we were unable to record serial echocardiographic examinations. Hereby, we report a comprehensive hemodynamic evaluation by echocardiography in a cohort of patients with COVID-19 sepsis. We identified four homogeneous and coherent physiological clusters. Indices of LV systolic function were positively correlated with RV function and inversely correlated with one LV afterload parameter, while no association was found with cardiac preload. AMI was common and associated with alteration of LV and RV functions. Feasibility and safety of echocardiography were good, and the test had a clinical impact on patient management in a majority of cases. Risk factors associated with acute respiratory distress syndrome and death in patients with coronavirus disease 2019 pneumonia in Wuhan, China Left ventricular systolic dysfunction during septic shock: the role of loading conditions Prevalence and prognosis of cor pulmonale during protective ventilation for acute respiratory distress syndrome Monitoring of right-sided heart function Cardiac dysfunction in sepsis Early dynamic left intraventricular obstruction is associated with hypovolemia and high mortality in septic shock patients Endothelial cell infection and endotheliitis in COVID-19 Pulmonary vascular endothelialitis, thrombosis, and angiogenesis in covid-19 Cardiac involvement in a patient with coronavirus disease 2019 (COVID-19) The Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3) Clinical course and risk factors for mortality of adult inpatients with COVID-19 in Wuhan, China: a retrospective cohort study Cardiovascular implications of fatal outcomes of patients with coronavirus disease 2019 (COVID-19) Severe SARS-CoV-2 infections: practical considerations and management strategy for intensivists Guidelines for the management of arterial hypertension Feasibility, reproducibility and diagnostic usefulness of right ventricular strain by 2-dimensional speckle-tracking echocardiography in ARDS patients: the ARD strain study Use of speckle-tracking strain in preload-dependent patients, need for cautious interpretation! Ann Intensive Care Echocardiography in the time of COVID-19 Utilization and appropriateness of transthoracic echocardiography in response to the COVID-19 pandemic COVID-19 pandemic and cardiac imaging: EACVI recommendations on precautions, indications, prioritization, and protection for patients and healthcare personnel Pulmonary embolism in COVID-19 patients: awareness of an increased prevalence Impaired cardiac function is associated with mortality in patients with acute COVID-19 infection Diagnostic accuracy and therapeutic impact of transthoracic and transesophageal echocardiography in mechanically ventilated patients in the ICU Global evaluation of echocardiography in patients with COVID-19 Cardiovascular clusters in septic shock combining clinical and echocardiographic parameters: a post hoc analysis Relationship between the tricuspid annular plane systolic excursion and right and left ventricular function in critically ill patients Echocardiographic abnormalities and predictors of mortality in hospitalized COVID-19 patients: the ECHOVID-19 study Prognostic value of right ventricular longitudinal strain in patients with COVID-19 Diastolic dysfunction and mortality in early severe sepsis and septic shock: a prospective, observational echocardiography study Left atrial structure and function, and left ventricular diastolic dysfunction: JACC state-of-the-art review Characterization of myocardial injury in patients with COVID-19 Potential effects of coronaviruses on the cardiovascular system: a review The spectrum of cardiac manifestations in coronavirus disease 2019 (COVID-19) -a systematic echocardiographic study Acute respiratory distress syndrome (ARDS)-associated acute cor pulmonale and patent foramen ovale: a multicenter noninvasive hemodynamic study Physical distancing, face masks, and eye protection to prevent person-to-person transmission of SARS-CoV-2 and COVID-19: a systematic review and metaanalysis Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations We are very indebted to all physicians and nurses of Henri Mondor Medical Intensive Care Unit for their good hand in providing care to COVID-19 patients. The online version contains supplementary material available at https://doi. org/10.1186/s40560-020-00516-6.Additional file 1. Complement on methods: echocardiography, Speckle tracking imaging, assessment of contractility and loading conditions and statistical analysis.Additional file 2: Fig. S1 . Forest plot of odds ratios (with 95% confidence interval) of variables associated with day-28 mortality by univariate logistic regression.Additional file 3: Table S1 . Baseline characteristics and organ failure at time of echocardiography in critically-ill patients with Coronavirus -19 sepsis, according to the need for vasopressor.Additional file 4: Table S2 . Echocardiographic parameters in criticallyill patients with Coronavirus -19 sepsis according to the need for vasopressor.Additional file 5: Table S3 . Association between E/A and mortality at day-28 by logistic regression after adjustment for age. Authors' contributions FB, PM, and AMD designed the study and wrote the manuscript. FB, PM, TH, LAA, and LAC collected the data and performed echocardiography. KR, NdP, GC, and GD helped design the study. All authors read and approved the final manuscript. The present study has been conducted without any financial support. All data generated and analyzed during the study are included in the published article and can be shared upon request. All authors helped to revise the draft of the manuscript. All authors read and approved the final manuscript.Ethics approval and consent to participate The study was approved by the institutional ethical committee of the French Intensive Care Society as a component of standard care, and patient consent was waived as per the French law. Information about the study was given to families. Not applicable. The authors declare that they have no competing interests.