key: cord-1055932-cnwicpmn authors: Mekonnen, Besufekad; Solomon, Nahom; Wondimu, Wondimagegn title: Healthcare Waste Status and Handling Practices during COVID-19 Pandemic in Tepi General Hospital, Ethiopia date: 2021-01-30 journal: J Environ Public Health DOI: 10.1155/2021/6614565 sha: 6e7672863a25d6d22490a7d9d802259e8bc9a7c3 doc_id: 1055932 cord_uid: cnwicpmn BACKGROUND: Mismanagement of healthcare waste (HCW) during the COVID-19 pandemic can facilitate the transmission of coronavirus. Regarding this problem, there is gap of evidence in Ethiopia, and this study aimed to assess the HCW generation rate and management in Tepi General Hospital, southwest Ethiopia. METHODS: Institution-based cross-sectional and case studies were conducted. The total amount of waste generated and its type among various case teams were compared using the Kruskal–Wallis test. Spearman's rank correlation coefficient (r) was used to assess the correlation between the total numbers of patients and the total amount of HCW generated. Qualitative data were transcribed verbatim, translated to English, and analyzed with Open Code version 4.02 software, and content analysis was followed. RESULTS: The total mean weight (±SD) of waste generation rate in all service units of the hospital was 492.5 ± 11.5 kg/day. The higher proportion (61.9%) of the total HCW produced was general waste and the remaining (38.1%) was hazardous waste. There was a statistically significant (X(2) = 82.1, p < 0.001) difference in daily HCW generation rate among different case teams. Similarly, the hospital waste generation amount and total patient flow had a strong positive linear relationship (r = 0.7, p=0.032). COVID-19-related medical wastes were not properly handled, segregated, stored, and disposed. There was a scarcity of resources needed to manage HCW, and available resources were utilized poorly. Overall, healthcare wastes were managed as usual (pre-COVID-19). CONCLUSION: The mean HCW generation rate in Tepi General Hospital was high. Overall, wastes were mismanaged, and COVID-19-related HCWs have been managed as usual. Availing of important resources and training the concerned bodies should be considered during the crisis of COVID-19. Healthcare waste (HCW) is a collection of waste generated by healthcare establishments, research facilities, laboratories, and home-based healthcare such as dialysis and insulin injection. Broadly, HCW can be classified as hazardous (healthcare risk) and nonhazardous (general) waste. Nonhazardous waste does not pose any specific biological, chemical, radioactive, or physical hazard, whereas hazardous waste can pose several health and environmental risks [1, 2] . Hazardous HCW contains potentially harmful microorganisms that can infect hospital communities and the general public. It may also be a source for drug-resistant microorganisms that spread from health facilities into the environment. In general, health risks associated with HCW and by-products include sharps-inflicted injuries, toxic exposure to pharmaceutical products, chemical burns, air pollution, thermal injuries, and radiation burns [3] . In lowincome countries, including Ethiopia, HCW is often not separated into hazardous or nonhazardous waste, making the real quantity of hazardous waste much higher [3, 4] . e current pandemic of coronavirus disease-19 (COVID- 19) brings an additional challenge in the waste management of healthcare facilities. Hospitals produce more waste than usual during COVID- 19. e diagnosis and treatment of COVID-19 produce wastes that include masks, gloves, gowns, and other protective equipment that could be infected with the virus. e amount of single-use plastics being produced is also greatly increased [5] [6] [7] . Inappropriate management of waste, especially during COVID-19, can predispose healthcare workers, patients, and the general public to coronavirus since the virus can survive on inanimate objects and different surfaces in the hospital [8] [9] [10] . e World Health Organization (WHO) recommends that all HCWs produced during the care of COVID-19 patients should be collected safely in designated containers and bags, treated, and then safely disposed of or treated, or both, preferably on-site. Furthermore, if waste is moved offsite, it is critical to understand where and how it will be treated and destroyed. All who handle HCW should wear appropriate personal protective equipment (PPE) and perform hand hygiene after removing it [11] . Similarly, as per the recommendations of both the Ministry of Health (Ethiopia) and the Ethiopian Public Health Institute, all HCWs produced during the care of COVID-19 patients must be considered as infectious waste and should be collected safely in designated containers and bags, treated, and then safely disposed [12] . Ethiopia is already stressed with hospital waste before the COVID-19 pandemic, and currently, there is an unpredicted increase in the volume of medical waste [4] . Confirming that COVID-19-related hospital waste is timely, tidy, efficiently, and harmlessly disposed and end up in the safest dumpsite has also become an important part of the battle against the pandemic. Evidence on the HCW generation rate, type of waste generated, and its management system is very important in designing proper hospital waste management systems during the COVID-19 pandemic. However, in Ethiopia, there is no study performed on the amount and types of waste generated from healthcare facilities during the COVID-19 pandemic. erefore, this study aimed to assess the HCW generation rate and its management in Tepi General Hospital, Southwest Ethiopia. Period. Institution-based cross-sectional and case studies were conducted in Tepi General Hospital from July 1 to 30, 2020. e hospital is found in Southern Nations, Nationalities, and People's Region State, and it is one of the newly constructed hospitals in Southern Ethiopia. It was established in 2014 and providing healthcare services for more than six hundred thousand populations. Currently, it is serving as COVID-19 isolation and treatment center for people of the Sheka zone and partly for those from the other three zones of Southwest Ethiopia. e facility had 188 beds in four wards which include surgical, medical, pediatric, and gynecology/obstetrics. Outpatient departments (OPD) include adult OPD, pediatrics OPD, maternal and child health clinic, antiretroviral clinic, tuberculosis clinic, emergency case team, follow-up clinic, and others. Moreover, the hospital had a pharmacy, laboratory, and imaging (radiology) case teams. In the first quarter of 2020, the average monthly inpatient and outpatient visits of the hospital were 228 and 3562, respectively. Techniques. All service units (case teams) in the hospital (inpatients, outpatients, laboratory, operation theater, pharmacy, radiology, and kitchen) were considered as a source of HCW generation. A purposively selected 42 workers of the hospital have participated in in-depth interviews. e waste generation data were collected by using observational checklists and measurement apparatus. e observational checklists were prepared to observe and evaluate how the hospital segregate, collect, transport, treat, and dispose wastes. A standard weighing scale was used to quantify the generation rate of HCW. HCWs were collected and measured daily for seven consecutive days. Empty plastic buckets of standard colors (black color for general waste, brown color for pharmaceutical waste, yellow color for infectious waste, and red color for pathological waste) were distributed daily to different sections of the hospital. Plastic bags with different colors were kept inside the respective buckets. e buckets and plastic bags were labeled to indicate the different categories of the HCWs, the place of generation, date of collection, and sample number. Waste weighing and recording station was arranged in a convenient site within the vicinity of the hospital. en, the collected wastes in plastic bags were removed every morning, and the weight was measured at 8:00 AM using a weighing scale, capacity range from 15 kg to 25 kg. e measurement was taken three times, and the mean of three measurements was used as the final weight of wastes. Seven BSc nurses (data collectors) and two public health officers (supervisors) were recruited and trained for data collection. Before data collection, two-day training was given on the purpose of the study, data quality, type of HCWs, the use and calibration of a weighing scale, infection prevention, and control techniques including proper use of PPE. Data collection guideline was developed and used to facilitate the training. Data were recorded daily in a suitable datasheet. Weight scales were arranged and then calibrated every morning. Moreover, daily on-site supervision was made by investigators and supervisors. e pretest was performed before the actual data collection begins, and the daily meeting was arranged to improve data quality. Accordingly, the amendment was made based on the result of the pretest. To get details of the current status of waste management systems of the hospital, additional qualitative data were collected from workers who have direct and major contact with waste management through in-depth interviews. Workers include waste handlers and team leaders, nurses, midwives, laboratory technicians, medical doctors, hospital manager, and others. An interview tool (guide) was used for conducting a face-to-face interview. e interview tool guides the participants to discuss on the waste segregation practice of the hospital, how the hospital collects and transports waste, how the hospital finally disposes the waste, and overall, how the waste is managed during COVID-19. All interviews were audio-recorded and field notes were taken. Meanwhile, an on-site observation was made to observe the status of the current waste management systems of the hospital. e number of outpatients and inpatient flow data for the study period was taken from the patient registration office. e number of inpatients and outpatients was used to calculate the daily waste generation of the hospital. e data collected through measurement and observation checklist were entered and compiled by using SPSS version 22 computer software packages. e total amount of waste generated and its type among various case teams were compared using the Kruskal-Wallis test as the data distribution was not homogeneous (with unequal variance) even when transformed. Spearman's rank correlation coefficient (r s ) was used for testing the existence of any bivariate correlation between the total numbers of patients and the total amount of healthcare waste generated. In addition, daily and annual waste generation rates were described and presented using tables. e annual healthcare waste generation rate was estimated by multiplying the mean healthcare waste generation rate in kg per day by 365 days (the assumption was each patient who visited the hospital may generate the same amount of HCW throughout the year). Qualitative data were transcribed verbatim, translated to English, and analyzed with Open Code version 4.02 software, and content analysis was followed. Codes and categories were developed, and findings were summarized by supporting with quotes from respective study participants. Ethical clearance was obtained from the Ethical Review Committee of Mizan-Tepi University, College of Health Science. Written consent was obtained from each study participant. Each study participant was briefed with the objective, benefit, and procedural steps of the study. Voluntary participation was assured, and the right to interrupt from the interview was clearly stated. Anonymity and confidentiality of the data were also ensured. A total of 752 patients have visited Tepi General Hospital during data collection time (within one week) in all health service delivery units. Of these, 212 (28.2%) patients were admitted to the inpatient department and 540 (71.8%) were seen at OPDs. e higher proportion (61.9%) of the total HCW produced was general waste and the remaining 38.1% was hazardous or risk waste. e types of hazardous wastes generated in Tepi General Hospital were sharps, infectious, pharmaceutical, and pathological (placenta and blood) wastes. e mean (±SD) generation rate of sharps, infectious, pharmaceutical, and pathological wastes in the studied hospital was 7.2 ± 0.9 (1.5%), 158.7 ± 0.4 (32.2%), 19.2 ± 0.5 (3.9%), and 2.3 ± 0.2 (0.5%) kg/day, respectively. More than a half (0.6) kg of waste was produced by one patient daily. Totally, an estimated yearly waste generation rate of the hospital was 179,762.5 kg/year (Table 1) . Units. e sharp, infectious, and pharmaceutical hazardous wastes were mainly generated from wards. However, the highest share of the pathological waste was from the gynecology unit. ere was no hazardous waste generated from the kitchen. Generally, the maximum and minimum amounts of hazardous wastes were generated from wards and radiology room, respectively (Table 2 ). e highest amount ((48.2%) 237.3 kg/day) of the hospital waste was generated from the kitchen room, whereas that of the lowest amount ((0.9%) 4.3 kg/day) was generated in the radiology room. e Kruskal-Wallis test indicated a statistically significant (X 2 � 82.1, p < 0.001) difference in daily healthcare waste generation rate among different case teams. is implies that the type or specialty of case teams was a factor for the generation rate of HCWs. Spearman's rank correlation coefficient (r s ) estimation showed a strong positive linear relationship between the amount of hospital waste generation and the total patient flow (r � 0.7, p � 0.032) ( Table 3) . A total of 42 health workers have participated in an in-depth interview ( Table 4 ) and discussed what the waste management practices of the hospital look like. e response of participants and the observational findings are summarized under a few categories. As we have observed and study participants reported, hospital wastes were temporarily stored using plastic buckets with cover for nonsharp wastes. Safety boxes were used for sharp waste in the emergency room and surgical and gynecological wards. It was also reported that the segregation of HCW by its type at the point of generation and pretreatment of infectious wastes were poorly practiced in the hospital. Majorities of study participants have pointed out that color-coded waste segregation materials were not adequately available in each unit, and front-line health service workers did not segregate those wastes as hazardous and nonhazardous. One of the study participants explained the issue as follows. ere are mixed wastes on the color-coded bins which are due to inappropriate waste segregation practice by concerned bodies of the hospital. (a nurse study participant) Almost all study participants have discussed that, though waste from the outpatient department is collected within 24 hours' intervals, the hospital has no fixed time to transport wastes into the designated area. All waste handlers have reported that they have duty gloves but they do not use during waste collection and transportation. However, they have revealed that they lack safety boots and face masks, and for that reason, they are obliged to wear their habitual personal shoes during their routine working time. One of them depicted the concern as follows. It was observed and study participants reported that the infectious medical HCWs including face masks and nonrisk HCWs are not collected on separate plastic barrel containers; rather, infectious and noninfectious wastes are usually mixed and transported into an incinerator room. reported that the waste incinerator is used for disposal of all medical infectious wastes such as sharp materials (syringe, needles, blades, and others), anatomical wastes, used face masks, and paper towels. On the other hand, the majority of study participants discussed that wastes including used batteries, broken thermometers, radioactive waste, and PVC plastic-like IV bags were not separated and disposed properly in the vicinity. Again, silver and X-ray films from radiotherapy were not managed and recycled properly. e following are part of the responses from study participants. Actually we have an incinerator and other waste management systems but I can't say we are fully practicing as recommended and expected of us. We are working for improvements to make our working environment safe. (a medical doctor study participant) Most study participants have pointed out that COVID-19-related healthcare waste disposal was not arranged by specifically trained staff and special vehicles or supporting materials. ey have also mentioned that all healthcare workers and waste handlers did not take training on medical waste management, especially on waste segregation at the time of the COVID-19 pandemic. Standard operating procedures were not established, and the hospital did not have a healthcare waste management committee too. Medical activities generate waste that should always be discarded at the point of use by the person who used the item. e quantity of HCW generated should always be minimized, and precautions must be taken during their handling particularly in the time of COVID-19 [6, 13] . e average daily HCW generation rate of Tepi General Hospital was 1.88 kg/bed/day, and this is higher than the findings of the studies conducted in Mizan-Tepi University Teaching Hospital and Adama Referral Hospital, Ethiopia, which reported average waste generation rates of 0.164 kg/bed/day and 1.23 kg/bed/day, respectively [14, 15] . e highest waste generation rate in the current study might be due to the COVID-19 pandemic which brings a new threat to the environment especially in low-income countries [16] . e patient flow was positively correlated to the waste generation rate in the studied hospital. e pandemic of the COVID-19 brings an increased patient flow to the hospital which in turn leads to a high amount of wastes generated, and therefore, proper waste management practices should be implemented. e hazardous HCW is associated with a risk of infecting workers handling HCW and others. Consequently, it requires careful waste management compared to general [14, 17] . e discrepancy might be due to the differences in hospital size, patient flow, and waste management practices among different hospitals. However, our finding is two times higher than the WHO report which states that 15% of HCWs are hazardous [2] . e higher proportion of hazardous waste generation may be attributable to poor segregation practice in the studied hospital. As it was noted from this study, the resources required to segregate wastes were inadequate, and the front-line health service workers did not segregate wastes using available materials. During the pandemic of COVID-19, the priority attention was given mainly to sharp materials by ignoring different infectious wastes such as facemasks. However, facemasks might be the source of infection for coronavirus. As a result, hazardous wastes should be segregated properly. Proper segregation of waste can reduce the treatment and disposal costs and the risks of infecting workers handling HCW. Moreover, the part of the HCW that is hazardous and requires special treatment could be reduced to some 2-5% if the hazardous part was immediately separated from the other wastes [9, 13] . erefore, the poor segregation practice in the studied hospital needs important attention especially during the crisis of COVID-19. e waste collection, transport, treatment, and disposal practices of the Tepi General Hospital were substandard. In this crisis time, all people in the country are recommended to protect themselves from COVID-19 by using different PPE. Surprisingly, the waste handlers, the priority groups to use PPE, in Tepi General Hospital were facing the scarcity of the PPE such as safety boots and facemasks. ey were not using their duty gloves, and this might be due to the lack of awareness creation strategies such as training since they were also reporting that they did not take any training which guides them on how to handle wastes during COVID-19. Wastes were also collected with an open container, and some of the wastes were ended up with open dumping. Furthermore, the absence of standard operating procedures and the healthcare waste management committee was an important finding in the hospital. is is in contrary to the national and international (WHO) recommendations of proper waste management during COVID-19 and the experiences of other countries [11, 12, [18] [19] [20] [21] . e mean HCW generation rate in Tepi General Hospital was high, and overall wastes were mismanaged. Although available resources were poorly utilized, the scarcity of vital inputs for proper waste management was one of the important findings. Moreover, COVID-19-related HCW was being managed as usual, and no different waste management method was employed so far. Availing important resources and training the concerned bodies should be considered during the crisis of COVID-19. Due to the lack of comparable studies conducted during COVID-19, the comparison was performed with studies that were performed before the pandemic. Moreover, our study was conducted in single site and it could not be generalizable to other settings. us, large-scale studies which can also identify the potential determinants of COVID-19-related waste generation and management practices are recommended. Healthcare waste(s) kg: Kilogram OPD: Outpatient department PPE: Personal protective equipment SD: Standard deviation SPSS: Statistical Package for Social Sciences WHO: World Health Organization. e data that support the findings of this study can be obtained from the corresponding author upon reasonable request. e authors declare that they have no conflicts of interest. Safe Management of Wastes from Health-Care Activities Safe Management of Wastes from Health-Care Activities: A Summary World Health Organization (WHO), Health-Care Waste Healthcare waste management current status and potential challenges in Ethiopia: a systematic review COVID-19 Waste Management Fact Sheet Challenges and strategies for effective plastic waste management during 6 Journal of Environmental and Public Health and post COVID-19 pandemic Coronavirus pandemic (COVID-19) and its natural environmental impacts Surface distribution of severe acute respiratory syndrome coronavirus 2 in Leishenshan Hospital in China Covid-19 creating another problem? Sustainable solution for PPE disposal through LCA approach SARS-CoV-2 in wastewater: challenges for developing countries Hygiene and Waste Management for the COVID-19 Virus, World Health Organization Ministry of Health and Ethiopian Public Health Institute, Health Care Waste Management SOP for COVID-19, Ministry of Health and Ethiopian Public health institute United Nations Environment Programme and World Health Organization, Preparation of National Health-Care Waste Management Plans in Sub-Saharan Countries: Guidance Manual Healthcare waste generation and management in public healthcare facilities in Adama, Ethiopia Assessment of health care waste generation rate and evaluation of its management system in Mizan Tepi University Teaching Hospital (MTUTH) Biomedical waste amid COVID-19: perspectives from Bangladesh Healthcare waste composition and generation rate in Menellik II Referral Hospital COVID-19 waste management: effective and successful measures in Wuhan, China Infection prevention and control compliance in Tanzanian outpatient facilities: a cross-sectional study with implications for the control of COVID-19 Clinical waste management under COVID-19 scenario in Malaysia Medical waste generation during COVID-19 (SARS-CoV-2) pandemic and its management: an Indian perspective No specific fund was obtained from anybody to conduct this study. e authors acknowledge Tepi General Hospital's administrative and clinical staff members for their active participation in this study.