key: cord-1054984-vpehn6nx authors: Minich, Jeremiah; Ali, Farhana; Marotz, Clarisse; Belda-Ferre, Pedro; Chiang, Leslie; Shaffer, Justin P.; Carpenter, Carolina S.; McDonald, Daniel; Gilbert, Jack; Allard, Sarah M.; Allen, Eric E; Knight, Rob; Sweeney, Daniel A.; Swafford, Austin D. title: Feasibility of using alternative swabs and storage solutions for paired SARS-CoV-2 detection and microbiome analysis in the hospital environment date: 2020-08-18 journal: Res Sq DOI: 10.21203/rs.3.rs-56028/v1 sha: 9fe1b3d9feca1bca4daa727cc233d99e3ef78d9b doc_id: 1054984 cord_uid: vpehn6nx Background: Determining the role of fomites in the transmission of SARS-CoV-2 is essential in the hospital setting and will likely be important outside of medical facilities as governments around the world make plans to ease COVID-19 public health restrictions and attempt to safely reopen economies. Expanding COVID-19 testing to include environmental surfaces would ideally be performed with inexpensive swabs that could be transported safely without concern of being a source of new infections. However, CDC-approved clinical-grade sampling supplies and techniques using a synthetic swab are expensive, potentially expose laboratory workers to viable virus and prohibit analysis of the microbiome due to the presence of antibiotics in viral transport media (VTM). To this end, we performed a series of experiments comparing the diagnostic yield using five consumer-grade swabs (including plastic and wood shafts and various head materials including cotton, synthetic, and foam) and one clinical grade swab for inhibition to RNA. For three of these swabs, we evaluated performance to detect SARS-CoV-2 in twenty intensive care unit (ICU) hospital rooms of patients with 16 COVID-19+. All swabs were placed in 95% ethanol and further evaluated in terms of RNase activity. SARS-CoV-2 was measured both directly from the swab and from the swab eluent. Results: Compared to samples collected in VTM, 95% ethanol demonstrated significant inhibition properties against RNases. When extracting directly from the swab head as opposed to the eluent, RNA recovery was approximately 2-4x higher from all six swab types tested as compared to the clinical standard of testing the eluent from a CDC-approved synthetic swab. The limit of detection (LoD) of SARs-CoV-2 from floor samples collected using the CGp or TMI swabs was similar or better than the CDC standard, further suggesting that swab type does not impact RNA recovery as measured by SARs-CoV-2. The LoD for TMI was between 0-362.5 viral particles while SYN and CGp were both between 725–1450 particles. Lastly microbiome analyses (16S rRNA) of paired samples (e.g., environment to host) collected using different swab types in triplicate indicated that microbial communities were not impacted by swab type but instead driven by the patient and sample type (floor or nasal). Conclusions: Compared to using a clinical-grade synthetic swab, detection of SARS-CoV-2 from environmental samples collected from ICU rooms of patients with COVID was similar using consumer grade swabs, stored in 95% ethanol. The yield was best from the swab head rather than the eluent and the low level of RNase activity in these samples makes it possible to perform concomitant microbiome analysis. Since its appearance in early December of 2019, Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of coronavirus disease 2019 (COVID- 19) , has spread to 197 countries resulting in a total of 539,906 deaths and 11,669,259 con rmed cases as of July 8, 2020 [1] . As health o cials rush to contain the spread of the disease, federal governments are combating the economic fallout, and there is a pressing need to reopen the economies albeit safely, gradually, and in stages. Large-scale testing and contact tracing remain key for controlling viral spread. In addition,; environmental sampling of microbes can support the epidemiologic investigations of disease outbreaks [2, 3] and shows promise for monitoring SARS-CoV-2. However, there are supply and cost limitations with the products currently recommended required by the CDC protocol for sample collection supplies. For example, personal protective equipment, swabs and, viral transport medium (VTM), and personal protective equipment (PPE) are being depleted in developed nations like the United States, and are in even shorter supply in resource limited settings including low-and middle-income countries (3) . Broad SARS-CoV-2 surveillance requires microbiologic surface fomite sampling protocols, the e cacy of which hinges on requires inexpensive, readily available swabs and collection reagents to support the large sample sizes at geographic scales necessary to inform public health policy., and the growing need for environmental testing will place additional demands on current swab supplies. The use of the U.S. Centers for Disease Control (CDC)-recommended viral transport media (VTM) places an additional barrier to e cient and safe deployment of screening and sampling measures. VTM maintains viral viability and therefore the CDC recommends that all samples be handled in a biosafety level-2 (BSL-2) laboratory. VTM also contains antimicrobial agents that limit the type of research studies into likely to interfere with downstream assessment of the microbial context of SARS-CoV-2, such as microbial relationships with that may enable new insights into viral susceptibility and resistance as demonstrated by several recent reports [4] [5] [6] . Using inactivating sample collection solutions, such as microbiome assay-compatible alcohols, would increase the number of testing laboratories capable of performing SARS-CoV-2 screening, and ameliorate the risks associated with sample transport and processing. Given these considerations, validation of alternative strategies such as self-administered testing using consumer-grade materials and inactivating storage media is urgently needed. There are aspects of both the swab and the transport media which must be considered when developing a testing procedure for SARS-CoV-2. From a microbiome perspective, the primary concern with using alternative media and consumer-grade materials is the risk of contaminant RNases and/or PCR inhibitors. The presence of these molecules would increase the false negative rate of SARS-CoV-2 RNA by either degrading the virus, or interfering with reverse transcription and quantitative polymerase chain reactions (RT-qPCR) which are the basis for SARS-CoV-2 testing [7] . In addition, the ability to extract the virus from either the swab or the swab eluent must be elucidated. The xative property of ethanol could result in nucleic acids adhering to swab heads, reducing the ability to measure SARS-CoV-2 RNA from the swab eluent [6] . To fully address these concerns, large screening efforts comparing the recommended and alternative collection methods are needed. However, given the present scale and urgency of the COVID-19 pandemic outbreak, limiting this comparison to a small number of viable options would greatly expedite providing guidance for alternatives to the supply chain this process while minimizing costs. Here we characterize the suitability of detecting SARS-CoV-2 RNA in experimental conditions as well as COVID-19 patient and built-environment samples using viral-inactivating storage solutions and alternative medical-grade and consumer-grade swabs. Nasopharyngeal (NP) swabs were collected from COVID-19 positive individuals (n = 39) according to CDC guidelines and were stored in viral transport media (VTM) and transported to the lab on dry ice. For comparison, sterile synthetic-head, plastic-shaft ('SYN', BBL Culture swab REF-220135, Becton, Dickinson and Company) were used to collect nares samples by rotating the dry swab head in the nares for approximately 10 seconds from lab members, COVID-19 patients (n = 11), or healthcare workers (n = 11) in the Hillcrest ICU, and then immediately placed in 95% ethanol (EtOH), and transported to the lab on dry ice. Eluent nucleic acid extractions were performed on 200 µL of the swab eluent (either VTM or EtOH) using the Omega Mag-Bind® Viral DNA/RNA 96 Kit (catalog# M6246-03), which only uses chemical lysis and does not include a bead beating step. For nucleic acid extraction from the swab head, the MagMAX Microbiome Ultra kit (Cat#A42357, Thermo Fisher Scienti c) was used. For the direct comparison of SARS-CoV-2 extraction e ciency, we extracted EtOH eluent and swab separately from the same samples of COVID-19 patients (n = 24) with approval of the UC San Diego Institutional Review Board under protocols #150275 and #200613. RT-qPCR for VTM and 95% EtOH comparison using synthetic-tipped plastic swabs SARS-CoV-2 detection was performed following a miniaturized version of the CDC protocol. Each RT-qPCR reaction contained 4 µL RNA template, 100 nM forward and reverse primers, 200 nM probe, 3 µl TaqPath (catalog# A15299, Thermo), and RNase-free water to a total reaction volume of 10 µl. All primers and probes were ordered from IDT (catalog# 10006606). RT-qPCR was performed on the Bio-Rad CFX384 Touch Real-Time PCR Detection System following the CDC thermocycling guidelines. Serial dilutions of the Hs_RPP30 Positive Control plasmid (catalog# 10006626, IDT) or 2019-nCoV_N_Positive Control plasmid (catalog# 10006625, IDT) were included to extrapolate human RNase P (Rp) and SARS-CoV-2 copy numbers, respectively. The SARS-CoV-2 N1 marker gene was used for detection and quantitation [8] [9]. Validation of use of alternative swabs (testing inhibition of SARS-CoV-2 detection) The standard swab type approved for use in SARS-CoV-2 detection is a synthetic ber swab with a plastic or wire shaft synthetic head. In addition to a CDC compliant, we tested an additional ve alternative swabs that included both plastic and wood materials for the shaft and synthetic, foam, or cotton materials for the swab head. The exact devices used were sterile synthetic rayon head, plastic-shaft detection of SARS-CoV-2 was reduced with certain swab types from both the eluent (standard protocol) and swab head directly (new method). A total of six swab types were compared and All swabs were processed following the standard SARS-CoV-2 protocol provided by the CDC [6] . The six swab types were To evaluate if the raw swab materials had any background contaminants such as RNase, which would decrease the sensitivity, we added 600 ng of puri ed, DNA-free human lung RNA (Cat#AM7968, Thermo Fisher Scienti c) onto each of the six swab types in triplicate and immediately stored in two storage solutions (500 µL 95% EtOH and 500 µL 91% isopropanol). Separately, two sets of six, 10-fold serial dilutions of human RNA were included as controls directly. The same quantity of human RNA (600 ng) along with an equal volume (5 µL) of SARS-CoV-2 RNA was added to either 95% EtOH (n = 3) or 91% isopropanol (n = 3) in the presence of 0, 2.5, and 25 µg RNaseA (in triplicate) to assess any inhibition offered against RNase contaminants. Four negative (swab only) and four positive (swab + 600 ng spiked human RNA + 5 µL spiked SARS-CoV-2 RNA [~ 20,000 copies per µL]) controls were included. Limit of detection comparison of swabs using oor as substrate To estimate the limit of detection and compare the viral yield across three swab types (SYN, CGp, and TMI), a serial dilution of viral particles was spiked onto oor swabs. In brief, separate 25 cm x 25 cm areas of the oor from a low-tra c common room inside a building with no SARS-CoV-2 research activities (i.e., Marine Biology research building at UC San Diego) were swabbed with a total of 24 swabs per swab type. Swabs were processed in groups of six by swabbing a quarter of that 625-cm 2 space, with each swab ultimately covering an ca. 26-cm 2 area, the similar surface area (25 cm 2 ) used for detection of low biomass samples in JPL spacecraft assembly clean rooms based on previous work in the JPL spacecraft assembly facility [10]. Swabs were then stored at room temperature for ca. 1 hr in a 2-mL deep-well 96-well plate during transport back to a BSL-2 laboratory at UC San Diego. A single serial dilution of SARS-CoV-2 viral particles [BEI Resources: Cat# 52286, Lot# 70033548] was made at the following concentrations: 232000, 2320, 1160, 580, 290, 145, and 72.5 viral particles per µL. A total of 5 µL of each dilution, or water as a negative control, was pipetted onto each swab type in triplicate and then immediately placed into 95% EtOH. Swabs in EtOH were then stored overnight at -80 °C until processing. Upon processing, an additional 24 'no swab' controls were included whereby 5 µL of the dilutions were dispensed directly into the extraction plate lysis buffer. Samples were processed using the same nucleic extraction method as described for swab heads above, and eluted in 75 µL of elution buffer. For RT-qPCR, 5 µL of template was used for each marker N1 and Rp. To address potential issues of non-normality, total copies were compared across swab types at each individual dilution using Kruskal-Wallis tests with Benjamini-Hochberg FDR 0.05 post-hoc test. All study patients were hospitalized with clinical concerns for COVID-19 and received standard diagnostic testing. Study samples were collected from subjects' nares or hospital surfaces using three dry swab types (SYN, TMI, CGp) under the UC San Diego Institutional Review Board protocol #150275 and #200613. Both nasal samples and hospital surfaces were collected using three dry swab types (SYN, TMI, CGp). Nasal samples were collected by inserting the swab into one nostril to the depth of approximately 2-3 cm and rotated for 5-10 seconds. Hospital surfaces sampled included the oor inside the patient's room (ca. 625-cm 2 area) and the patient's bedrail. All swabs were immediately placed in a collection tube containing 0.5-1.0 mL 95% EtOH, stored on dry ice, and processed for RNA or total nucleic acid extraction (Supplementary Methods). All swab comparison-and hospital samples were processed according to the manufacturer's protocol using the MagMAX Microbiome Ultra kit (Cat#A42357, Thermo Fisher Scienti c), and eluted into 70 µL buffer. For RT-qPCR, 5 µL sample was processed using the standard SARS-CoV-2 protocol provided by the CDC (Cat# 2019-nCoVEUA-01 [11] ). A subset of 40 samples were processed for 16S rRNA sequencing using established EMP protocols (https://earthmicrobiome.org/protocols-and-standards/16s/). These included 18 oor samples, 21 nasal samples, and 1 negative control. Floor samples included all triplicates from the three swab types (SYN, TMI, and CGp) from two patient rooms (patient 7 and 18). The nasal samples included triplicates of all three swab types from patient 1, triplicates of SYN and CGp from patient 7, and triplicates of SYN and TMI from patient 18. The same previously extracted nucleic acid template, which was concurrently used for RT-qPCR, was used as template for 16S rDNA library generation (amplifying the DNA). Speci cally, 0.4 µL of nucleic acid was processed in 10 µL 16S rRNA PCR reactions following the miniaturized protocol [12] using the 515f/806r EMP primers, and sequenced on an Illumina MiSeq [13] [14] [15] [16] . Samples were then processed in Qiita (Study ID 13275) [17] and analyzed using the QIIME2 2020.6 [18, 19] pipeline with Deblur [20] 1.1.0 as the method of sOTU generation. Samples were visualized in PCoA plots in Qiita using EMPeror [21] . Beta diversity was calculated using Unweighted Unifrac and compared with PERMANOVA (999 permutations). Visualizations and statistical comparisons performed using PRISM 8.0 and the limit of detection determination were consistent with CDC recommendations whereby samples with a Ct value greater than Our experimental design sought to answer three primary questions: whether the e cacy of SARS-CoV-2 detection is in uenced by the following three variables: 1) does the swab storage solution (95% EtOH vs 91% isopropanol) impact the sensitivity of detection; 2) which sample fraction, swab head or eluent, provides better detection delity; and 3) does the swab head material type matter? To do this we designed a series of experiments to compare RNA recovery as measured by RT-qPCR using multiple swab types and storage solutions. We additionally did environmental sampling in a hospital environment with a subset of swab types for comparison. Feasibility of 95% EtOH for sample storage and extraction from use of swab head rather than eluent To evaluate the feasibility of switching from VTM to a more readily-available, viral-inactivating sample collection solution, we compared the extraction e ciency of synthetic-tipped plastic-shafted nasopharyngeal (NP) swab samples stored in VTM versus nasal samples collected using CDCrecommended synthetic-tipped plastic-shafted (SYN) swabs stored in 95% ethanol (EtOH). When mirroring the CDC protocol, which calls for extraction from 200 µL of the eluent from VTM surrounding NP swabs, we had signi cantly lower recovery of human RNA in 95% EtOH eluent compared to VTM ( Fig. 1a ; one-way ANOVA with Tukey's multiple comparison, VTM eluent vs. EtOH eluent p < 0.001). However, similar levels of human RNA were recovered when extracting from the EtOH-preserved swab head itself ( Fig. 1a ; one-way ANOVA with Tukey's multiple comparison, VTM vs. EtOH swab p = 0.3). In a subset of seven COVID-19 patient nares samples stored in 95% EtOH, we also detected signi cantly higher SARS-CoV-2 viral load in RNA extracted from the swab head versus eluent ( Fig. 1b ; one-tailed paired Student's t-test p = 0.03). To more quantitatively determine the effects of alcohol-based preservation media, we extracted RNA from a pure, commercial sample of human RNA added to water, EtOH, or 91% isopropanol, and found no impact on extraction e ciency ( Fig. 1c ; one-way ANOVA, p > 0.05). Next, we examined whether alcohol storage solutions had any protective properties of RNA, speci cally a possible inhibitory effect on RNases that might be present in the environment. If alcohol inhibits the RNaseA, one would expect to see similar amounts of RNA as without RNaseA added in control experiments. In the presence of abundant RNaseA added to the solution, 95% EtOH protected both human RNA and SARS-CoV-2 RNA better than 91% isopropanol. Only a moderate decrease in total RNA recovery was observed, at the most extreme concentration of 25 mg per reaction, which is equivalent to the standard amount used for RNA removal during DNA extraction (Fig. 1d) . Comparison of alternative swab types against standard CDC approved synthetic swab Given that the performance of eluent vs. swab-based extractions in each alcohol may depend on the swab tip and body composition, we next tested RNA recovery from both the swab head and the surrounding eluent from a range of medical-and consumer-grade swabs (Methods) (Fig. 1e) . The RNA yield was highest from swab heads compared to eluent regardless of the swab type and whether stored in 95% EtOH (p < 0.0001, U = 37, Mann-Whitney) or 91% isopropanol (P < 0.0001, U = 28, Mann-Whitney) (Fig. 1e-f) . The storage solution did not impact RNA quality (Supplemental Fig. 1b , Mann-Whitney, p > 0.05), although swab type had a minor impact (Supplemental Fig. 1c , Kruskal-Wallis p = 0.03, KW = 12.17) [22] . To compare impacts of various alternative swabs, we normalized the recovery of each test to SYN eluent, indicated by '1' (Fig. 1e) , which is the standard CDC approved method. Thus, any sample with a value greater than 1 would indicate an enhanced recovery of RNA, whereby less than 1 indicates a lower recovery of RNA compared to the standard. The RNA recovery ratio of swab-to-eluent and total yield varied among swab type (p < 0.0001, KW = 28.37, Kruskal-Wallis for eluent, and p < 0.0001, KW = 15.43, Kruskal-Wallis for swab heads) (Supplemental Fig. 2) . This difference in performance may relate to the differences in observed adsorption capacity across swab types (Shapiro-Wilkes p = 0.1, w = 0.8357; ANOVA p = 0.0001, F = 7.5, R 2 = 0.56). TMI adsorbed the least (84.5 µL, 20.4; mean, SD) followed by plastic shafts (SYN: 141 µL, 23.1; CGp: 143.3 µL, 29.9) (Supplemental Fig. 3) . CGp swabs had the highest recovery of RNA from the swab head, while TMI swabs had the highest overall recovery of RNA when combining both eluent and direct swab extractions (Fig. 1e, Supplemental Fig. 2 ). We next assessed whether the swab type used would impact the recovery of SARS-CoV-2 and alter the limit of detection when using non-CDC-recommended swabs (CGp or TMI compared to SYN). All negative controls for oor swabs were indeed negative for SARS-CoV-2 using N1 and N2 (Supplemental Table 1 , Fig. 2 ) and all 'no-swab' controls which only had SARS-CoV-2, were negative for human Rp (Supplemental Table 1 ). For the 'no-swab' and TMI swab, SARS-CoV-2 was detected in all of the three replicates at the lowest input of 362.5 genome equivalents 'GE', whereas the lowest dilution for all three replicates to be positive for CGp and SYN swabs was 1450 GE (Supplemental Table 1 , Fig. 2a) . This suggests the limit of detection for neat and TMI swabs is likely between 0 and 362.5 GE per reaction whereas both CGp and SYN were less sensitive with an expected limit between 750 and 1450 GE per reaction. There was a strong correlation between the input or theoretical GE and the measured GE with slopes all greater than 0.95 and the R 2 > 0.96. Despite TMI appearing to have the best overall performance in SARSs-CoV-2 detection followed by SYN and then CGp, the total viral yield did not differ across swab types at the lowest dilution of 362.5 (P > 0.05, Kruskal-Wallis test) (Fig. 2a) . Speci cally, multiple post-hoc comparisons showed that variation across swab-type only existed at the highest concentration (116,000 GE) with the TMI swabs having a higher viral recovery compared to SYN swabs (P = 0.04, KW = 7.21) (Fig. 2) . Rp yield was also compared across swab types and across viral inputs to characterize the variation in input biomass. For each swab type, human Rp gene was equally detected across the titrations indicating the swab method was su ciently controlled (Supplemental Fig. 4a ). Swab type, however, did suggest that the Rp gene was highest in the SYN swab as compared to the CGp and TMI swabs (Kruskal-Wallis: P < 0.0001, KW = 41.41) (Supplemental Fig. 4b) . This result suggests that SYN swabs may adsorb more biomass. However, when we compared the variation in Cq values of hospital samples of nares and oor from the same hospital using SYN swabs, we observed Rp values that varied over six orders of magnitude (Supplemental Figure S5) , much greater than the three orders of magnitude observed across swab types. Speci cally, for oor samples, the Rp yield (copies per extraction) range across swab types was 149-3368 copies for SYN, 0-3980 for CGp, and 0-207 for TMI. Based on the results from these initial experiments, we conducted a proof-of-concept study in the clinical setting by performing RT-qPCR for the SARS-CoV-2 N1 amplicon and human RNase P gene on RNA extracted from the swab head of nasal samples collected using TMI and/or CGp swabs alongside the recommended SYN swabs. Of the 20 participants sampled, 16 tested positive for SARS-CoV-2 at admission and were designated as COVID-19(+). The average time from diagnosis to sampling was ca. 4.2 days, with a NP swab test occurring within 72 hours of the time of nasal sampling. Of the 12 nasal samples using the SYN swab preserved in EtOH from COVID-19(+) patients, nine were positive for the presence of SARS-CoV-2 or a false negative rate of 25% (Fig. 3a) compared to 14/16 SARS-CoV-2 positive NP swabs for the same group of patients, a false negative rate of 12.5%. For CGp and TMI swabs, 8/12 and 5/10 were positive for nares, respectively (Fig. 3a) . These rates of false negatives are similar, as compared to the 37.5% false negative rate reported for plastic-shafted synthetic-tipped nasal swabs collected in VTM and extracted from the eluent (Wang et al. 2020). As the degree of viral shedding is known to vary over the course of the disease [23] , we compared the performance in the subset of COVID-19(+) patients with an NP-positive swab result within 72 hours of the time of sampling, and observed reduced false negative rates of 18.2% (SYN), 25% (TMI), and 30% (CGp). We next compared success rates across swab samples from the built environment. On the oor samples, the CGp had the highest success rate at 75% in detection of SARSs-CoV-2 from SARSs-CoV-2 positive patient rooms whereas SYN detected SARSs-CoV-2 in 63% of rooms, and TMI in 44% of rooms (Fig. 3a) . Bedrail samples had the lowest frequency of detection, 5/16 (31%), for each swab type (Fig. 3a) . For SARSs-CoV-2 negative patients admitted to the same hospital for other reasons, all nares and bedrail samples were negative, whereas one oor sample using the SYN swab detected SARSs-CoV-2 (Fig. 3b) . The observed differences in detection among nares and environmental samples, taken in context of results that Since our previous experiment demonstrates that suggest swab type does not impact SARSs-CoV-2 detection, this suggests that variation in sample collection from the nares and other environmental samples has an important role in detection sensitivity. When swabbing an environmental surface or body site (i.e., nares), there is inherent variation in the swabbing event which can be attributed both to stochastic differences in biomass (human cells, dust, etc.) and the overall assay (nucleic acid extraction and RT-qPCR). To evaluate if certain sampling locations or swab types were more variable than others, we calculated the intra-assay coe cient of variance (CV) of the Cq values. The CV was signi cantly higher in patient nasal samples compared to control (RNA spike-in) samples (P = 0.0018), with a median difference in variance of 2.5 (Supplemental S6a). Swab types also demonstrated an effect with CGp and SYN differences being signi cant as compared to the control (P = 0.0012) (Supplemental Figures S6b) . To determine the feasibility of co-opting nucleic acid for microbiome processing, we processed a subset of samples (n = 40) spanning a total of three patients, two sample types ( oor and nasal) and the three swab types. After processing with Deblur, the total number of reads per sample were compared (Fig. 4a) . Read counts were highly variable across sample types and for each patient but were consistent within the swab types for each comparison. For oor samples in patient room 18, SYN swabs had the highest number of reads followed by TMI and CGp. For nasal samples however, patient 1 had the higher read counts from TMI while patient 7 and 18 both showed slightly lower read counts for SYN swabs as compared to alternative swabs. The differences were minor however and are primarily differentiated by patient room (Fig. 4a) . After rarifying to 5000 reads a PCoA plot was generated from using Unweighted UniFrac distances (Fig. 4b) . Samples which were collected using different swab types clustered together when controlling for patient room and sample type, suggesting indicating that the swab type used does not have a negative impact on microbiome analysis (Fig. 4b) . When analyzing all samples together, sample_type ( oor vs nasal) and patient number (7 vs 18) were both signi cant drivers of the microbiome community (sample_type: PERMANOVA n = 24, group = 2, P = 0.001, Fstat = 6.94; patient_num PERMANOVA n = 24, group = 2, P = 0.001, Fstat = 6.92) whereas swab type did not have an effect (P = 0.164). Distances between swab types were lower than distances between patients for both oor (Supplemental Figure S7a ) and nasal (Supplemental Figure S7b ) samples, with patient 7 exhibiting higher variation than patient 18. Floor samples generally had a higher microbial diversity compared to nasal swabs, with Staphylococcus, Corynebacterium, Pseudomonas, Streptococcus, and Enterobacteriaceae being the more dominant taxa. Nasal samples however were mostly enriched by either Staphylococcus or Corynebacterium, with patient 7 having a higher abundance of Lawsonella (Fig. 4c ). When assessing whether it will be possible to adapts and switch collection methodology to enable more affordable, more widely available, and more inter-assay compatible collection methods for SARS-CoV-2 monitoring, it is key to understand the feasibility of using both alternative swabs and sample storage solutions. Here we provide evidence that the variation observed in a given SARSs-CoV-2 experiment is primarily driven by the time and method of sample collection rather than by the swab type, storage solution, and subsequent extraction and RT-qPCR. When using alcohol-based storage solutions, we demonstrate that the nucleic acid or viral particles tend to become enriched on the swab head rather than the eluent and thus we recommend extracting directly from the swab head itself. We demonstrate that RNA can be successfully extracted from consumer-grade swabs stored in alcohol without compromising RNA integrity or yield. Of note, wooden-shafted swabs performed poorly only when extracting from the eluent, suggesting that RNA adsorption onto the shaft, rather than RT-qPCR inhibitors, may be the source of interference with current eluent-based testing methods for this swab type. As cotton-tipped swabs and alcohol-based storage solutions are compatible with standard microbiome-and metabolome analyses not feasible with VTM, these alternatives could enable more widespread assessment of the microbial context of SARS-CoV-2 RNA in human and environmental samples, including associated microbiome features. We also provide preliminary evidence that nasal samples collected using more widely available, consumer-grade, cotton-tipped swabs can be used to detect SARS-CoV-2 in the clinical setting. As cottontipped TMI swabs had only a marginally reduced performance compared to CDC-compliant SYN swabs for nasal samples compared to NP results, these swabs provide the potential as an attractive alternative for methods such as metabolomics that are complicated by the background from incompatible with synthetic-tipped swabs, as well as suggesting the expanding the pool of available medical-grade collection consumables could be expanded. Notably, this variation is less than that observed when comparing different methods for assessing the presence of SARS-CoV-2. Larger-scale testing will be needed to expand and con rm these ndings, but our data suggests that these two swab types, in either 95% EtOH or isopropanol, would provide a valuable starting point. When considering environmental sampling, our data suggest that TMI and CGp swabs may outperform or at least are similar to, CDC-compliant SYN swabs for collecting samples to detect SARS-CoV-2 from oor samples. We provide molecular evidence demonstrating the feasibility of detecting SARs-CoV-2 from oor samples with a limit of detection (ca. 362.5 copies per extraction for TMI) and (750-1450 copies per extraction for CGp and SYN) similar to that of other published studies (500 copies per extraction) [24] . Additional testing using pre-wetted swab heads, as performed in other built-environment studies [25] [26] [27] [28] [29] , is warranted to determine if this would improve the ability of all swab types to detect SARS-CoV-2 in the hospital room environment. The detection of SARS-CoV-2 on ca. 50% of COVID-19(+) participants' bedrails and ca. 75% of oors, as well as the detection of SARS-CoV-2 on the oor of one non-COVID patient, suggests increased cleaning measures may need to be taken. Indeed, the oor may be a potentially important reservoir for viral exposure, as shoe-covers are not currently recommended by the CDC. However, additional testing is needed to determine whether viable virus particles remain on these surfaces. Since detection largely does not differ across swab types, this suggests that differences seen in the quantitation of SARSs-CoV-2 in the clinic in a given oor or nasal sample is due to variation in the swabbing event itself rather than a molecular processing problem. Because of this, we recommend the need for standardization in medical devices used to collect both nasal and environmental samples speci c to SARSs-CoV-2 to improve overall accuracy. Lastly, our efforts to quantify the total noise in a given sampling event and sample processing itself demonstrate how variation in the act of swabbing combined with sample processing may lead to variance and at times lower than expected speci city. Secondary infections are an important and signi cant contributing factor to morbidity and mortality in COVID-19 patients [30, 31] . With metagenomics assays becoming more common for infectious disease diagnostics in the clinic [32] [33] [34] , developing molecular methods which enable simultaneous viral detection and metagenomic analysis is critical for understanding disease progression in at-risk populations. Since the storage method is a critical step in preserving microbiome integrity with 95% ethanol as a stable solution [35], our results further demonstrate and open the door for multi-omics processing and analysis of SARSs-CoV-2 samples. In summary, our results suggest detection of SARS-CoV-2 RNA in the environment could be performed using less expensive, consumer-grade materials and alcohol-based storage solutions. With the materials examined in this study, it is further conceivable that patients could collect samples from themselves, their environments at home, or their place of work, dramatically expanding the ability to deploy widespread methods for monitoring and predicting outbreak events. Additional con rmatory studies using consumergrade swabs would greatly support COVID-19 screening worldwide, particularly in resource-limited communities. Ethics approval and consent to participate All patient consent and sampling was done in accordance to two protocols: UC San Diego Institutional Review Board protocol #150275 and #200613 Consent for publication: Not applicable Availability of data and material: Data is available upon acceptance of the publication. Microbiome data is currently deposited in Qiita Study ID 13275 and will be submitted to ENI. Pu=Puritan 'commercial', CGw=wood 'consumer-grade'), extracted from 200µL eluent (blank bar) or the swab head. Recovery for each swab type is normalized to the CDC recommended method (eluent from PE swab). A '2' would indicate there was 2x more RNA recovered whereas a 0.5 would indicate a 50% reduction in RNA recovery. f) Total RNA copies per extraction for all samples which are grouped by sample-type (eluent or swab head) and storage buffer (95% EtOH or 91% isopropanol). Pairwise comparisons performed within sample-type (not signi cant) and across sample-type controlling for storage buffer (Mann-Whitney, U=test statistic). Limit of detection of SARs-CoV-2 viral particles across swab types (Synthetic rayon 'SYN', CGp, and TMI). "Noswab" refers to direct extraction of viral particles. a) Comparisons of total RNA recovery per extraction across swab types including 'noswab' performed at each dilution (Kruskal Wallis test). Comparison of (theory input Genome Equivalents 'GE') to measured GE of triplicates (mean, SEM) by RTqPCR of SARs-CoV-2. Non-linear regression analysis of each dilution series for noswab, SYN, CGp, and TMI swabs. Comparison of CDC approved SYN swabs, consumer-grade CGp and bulk TMI swab congruence compared to clinical-grade hospital tests using synthetic-tipped plastic shafted NP swabs for twenty participants in the clinical setting. a) SARs-CoV-2 positive patients (n=16) sampled with three swab types across three environments: nares, oor, and bedrail. '+' samples (dark grey = SYN, red = CGp, blue = TMI) refer to samples which tested positive for SARs-CoV-2 out of the total samples tested for that particular swab type (light grey bar). Percentage of positive tests per swab type are below x axis for each environmental sample. b) SARs-CoV-2 negative patients (n=4) with three swab types across three environments: nares, oor, and bedrail. Same nomenclature as above. Supplementary Files Mediterranean 828 Deaths Eastern. Cases 98, Europe 664 Deaths, Cases 2. 827 789 Situation in numbers (by WHO Region Microbiology of the built environment Centers for Disease Control and Prevention. Centers for Disease Control and Prevention SOP#: DSR-052-02-PREPARATION OF VIRAL TRANSPORT MEDIUM [Internet Considering the Effects of Microbiome and Diet on SARS-CoV-2 Infection: Nanotechnology Roles Using noninvasive metagenomics to characterize viral communities from wildlife Collection of Upper Respiratory Tract Specimens CDC/DDID/NCIRD/ Division of Viral Diseases. CDC 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel Coronavirus jolts labs to warp speed KatharoSeq Enables High-Throughput Microbiome Analysis from Low-Biomass Samples. mSystems Centers for Disease Control and Prevention High-Throughput Miniaturized 16S rRNA Amplicon Library Preparation Reduces Costs while Preserving Microbiome Integrity. mSystems Minor revision to V4 region SSU rRNA 806R gene primer greatly increases detection of SAR11 bacterioplankton Global patterns of 16S rRNA diversity at a depth of millions of sequences per sample Improved Bacterial 16S rRNA Gene (V4 and V4-5) and Fungal Internal Transcribed Spacer Marker Gene Primers for Microbial Community Surveys. mSystems Every base matters: assessing small subunit rRNA primers for marine microbiomes with mock communities, time series and global eld samples Qiita: rapid, web-enabled microbiome meta-analysis QIIME 2 Enables Comprehensive End-to-End Analysis of Diverse Microbiome Data and Comparative Studies with Publicly Available Data Reproducible, interactive, scalable and extensible microbiome data science using QIIME 2 Deblur Rapidly Resolves Single-Nucleotide Community Sequence Patterns. mSystems EMPeror: a tool for visualizing high-throughput microbial community data The RIN: an RNA integrity number for assigning integrity values to RNA measurements SARS-CoV-2 Viral Load in Upper Respiratory Specimens of Infected Patients Analytical sensitivity and e ciency comparisons of SARS-CoV-2 RT-qPCR primer-probe sets Microbial and metabolic succession on common building materials under high humidity conditions Microbial Similarity between Students in a Common Dormitory Environment Reveals the Forensic Potential of Individual Microbial Signatures Bacterial colonization and succession in a newly opened hospital Athletic equipment microbiota are shaped by interactions with human skin Longitudinal analysis of microbial interaction between humans and the indoor environment Surviving Sepsis Campaign: Guidelines on the Management of Critically Ill Adults with Coronavirus Disease 2019 (COVID-19) Clinical predictors of mortality due to COVID-19 based on an analysis of data of 150 patients from Wuhan, China Metagenomic sequencing with spiked primer enrichment for viral diagnostics and genomic surveillance Clinical Metagenomic Sequencing for Diagnosis of Meningitis and Encephalitis Clinical metagenomics Preservation Methods Differ in Fecal Microbiome Stability, Affecting Suitability for Field Studies. mSystems We thank research participants who donated samples, the health care professionals who assisted in the collection of samples, and Alison Vrbanac, Louis-Felix Nothias-Scaglia, and Shi Huang for assistance in transportation and Dominic Nguyen for sampling kit preparation. This research bene ted tremendously from lessons learned and techniques developed in the Sloan Microbiology of the Built Environment (MoBE program). We thank Stanley T. Motley for early discussion on nucleic acid stability, Sandrine Miller-Montgomery for guidance in RT-qPCR analyses. We thank Thomas F. Rogers and Nathan Beutler for providing the SARS-CoV-2 viral RNA used as a control in this study and David Pride for supplying samples from NP swabs in VTM for our comparisons. The authors declare they have no competing interests.Funding: This is a list of supplementary les associated with this preprint. Click to download.Additional les.docx SuppTable1.xlsx