key: cord-1054376-r0v9hf0k authors: Gupta, Arpit; Malhotra, Yogangi; Patil, Uday; Muradas, Ana R.; Lee, William T.; Krammer, Florian; Amanat, Fatima; Clare, Camille A.; Vinod, Suja; Ghaly, Emad title: In Utero Vertical Transmission of Coronavirus Disease 2019 in a Severely Ill 29-week Preterm Infant date: 2020-09-16 journal: AJP Rep DOI: 10.1055/s-0040-1715177 sha: 68acc6042a4781f005d9de80980362e16303717e doc_id: 1054376 cord_uid: r0v9hf0k Severe acute respiratory syndrome coronavirus 2 (SARS-Cov-2) or coronavirus disease 2019 (COVID-19) is currently in worldwide pandemic state with very limited data about the mode of transmission to the growing fetus. There are a few published cases of COVID-19 infection in the infants born to COVID-19 positive mothers where most of the reported cases were either mildly symptomatic with positive COVID-19 polymerase chain reaction (PCR) or had negative COVID-19 PCR raising the question of vertical transmission. We present a case of likely intrauterine transmission of COVID-19 infection in a critically ill premature infant born to a COVID-19 infected mother and describing her clinical course thus far. The clinical presentation in the infant is consistent with COVID-19 infection described so far in literature along with positive PCR, and positive COVID-19 serology: immunoglobulin G, immunoglobulin M, and immunoglobulin A. infant. All due airborne isolation precautions were taken. This is likely a case of newborn with in utero vertical transmission of COVID-19. The mother of the infant girl is a 31-year-old Gravida 2 Para 1 woman, who presented to the emergency room (ER) on April 9, 2020 with the chief complaint of fever, respiratory distress, and decreased fetal movement for 20 hours. Her fever started the day before presentation with maximum temperature of 102°F. Her respiratory symptoms included dry cough, chest tightness, and shortness of breath. She reported developing symptoms 10 days prior to presentation. She had sick contact with the father and her 2-year-old child, both of whom were symptomatic but not tested for COVID-19 infection. Her prenatal course prior to this illness was uneventful. In the ER, she was afebrile with stable vitals except tachycardia (103 beats/minute) and no apparent respiratory distress. She was transferred to obstetrical triage for fetal assessment. In obstetrics and gynecology triage, the fetal heart tracing was significant for decreased variability and late decelerations. The biophysical profile score was 2/10. The decision was made for immediate cesarean section under spinal anesthesia. All personnel in the operating room observed airborne precautions, and the mother was given an N-95 mask during the surgery. Rupture of membranes was done at delivery, and clear fluid was noted. Infant was born limp with poor respiratory effort. She was immediately placed under the radiant warmer, and resuscitation was performed as per the Neonatal Resuscitation Program. Infant was intubated for persistent apnea at 3 minutes of life, stabilized and transferred to the neonatal intensive care unit. Apgar's scores were 3, 5, and 7 at 1, 5, and 10 minutes respectively with heart rate always above 100 beats/minute. The infant had no contact with mother after birth. Arterial cord blood was significant for mixed acidosis (pH 7, pCO 2 78, and base deficit À15.2). Infant's birthweight was 1.33 kg (50th percentile), head circumference 28 cm (75th percentile) and length 41 cm (80th percentile). The rapid PCR (cepheid COVID-19 PCR) done on the mother right after delivery was positive. Her intraoperative blood count was significant for leucopenia (4,500), lymphopenia (1,400), and thrombocytopenia (26,000). She required 2 units each of platelets and fresh frozen plasma. Inflammatory markers sent after COVID-19 status confirmation were elevated: ferritin, 391 ng/mL (range ¼ 15-150) and procalcitonin: 0.120 ng/mL (range ¼ 0.020-0.080). A postoperative chest CT scan reported subtle peripheral opacities in bilateral lower lobes. Pathological examination of the placenta included acute and chronic villitis, intervillositis, and perivillous fibrin deposition likely representing severe placental hemorrhage consistent with disseminated intravascular coagulation. She remained stable postoperatively with no apparent respiratory distress and was discharged on day 4 of hospitalization. In the NICU, the infant was admitted in the negative pressure room under aerosol and droplet precautions. Her Ballard maturational assessment of gestational age was con-sistent with a 29-to 30-week preterm infant. Initial respiratory presentation was consistent with severe respiratory distress syndrome with bilateral homogeneous ground glass infiltrate on chest X-ray, requiring high ventilatory support and oxygen support (90% FiO 2 ). Early surfactant (Curosurf 2.5 mL/kg) was administered with improvement in FiO 2 requirement down to 60%. Over the course of the next 24 hours, she required two additional doses of surfactant to decrease oxygen requirement to 50%. The infant was started on empirical ampicillin and gentamicin. Blood culture remained negative for 5 days. She was kept nil per oral for 72 hours and was maintained on total parenteral nutrition. Expressed breast milk feeding was initiated on day 4 of life. Echocardiogram done on day 3 of life revealed atrial septal defect with left to right shunting and a small patent ductus arteriosus with bidirectional shunting. Both the ventricles were of normal size, and left ventricle was hyperdynamic. Head ultrasonography done on day 1 of life revealed bilateral grade III intraventricular hemorrhage (IVH), unrelated to her underlying thrombocytopenia, which developed on day 5 of life. Following American Academy of Pediatrics guidelines released on April 2, 2020, a sample for COVID-19 was sent at 24 hours of life, and the test result was positive. Repeat COVID-19 PCR tests sent on day 4 of life; 6, 12, 18, and 25 were all positive (►Table 1). With respiratory symptoms, positive endotracheal PCR and persistent right-side infiltrates, she was diagnosed with pneumonia (►Fig. 1). With improvement in respiratory symptoms, she was successfully extubated on day 20. Her initial CBC was unremarkable (April 9, 2020): white blood cells (WBC) 28K, hematocrit 50, and platelets 224,000. Over the course of the next few days, she developed leucopenia, lymphopenia, and thrombocytopenia requiring multiple red blood cells and platelet transfusion. She had hyperglycemia for first 2 days despite giving minimal glucose infusion rate. Her initial aspartate aminotransferase and alanine aminotransferase were elevated. Inflammatory markers procalcitonin, serum lactate dehydrogenase (LDH), and serum ferritin were also significantly elevated. C-reactive protein, blood urea nitrogen, and creatinine were normal for age. The results are summarized in ►Table 2. Serology test (ELISA SARS CoV-2) was performed on the infant on April 21, day 12 and on April 27, day 18. Both the specimens were strongly positive for Immunoglobulin (Ig)G reactive with both the spike antigen and the receptor binding domain (RBD) antigen of the virus. It was also strongly positive for IgM, reactive with both the spike and the RBD. A different serology test (ARIES SARS-CoV-2 Assay, Luminex USA) was also performed on day 18 serum specimen. It showed moderate IgA reactivity with the RBD along with the strongly positive IgG and IgM reactivity for both the spike RBD and the nucleocapsid antigens. All the serology results are shown in ►Fig. 2A and B. The information on in utero transmission of COVID-19 is very limited. There is no description yet on COVID-19 presentation in a premature infant. We report a severe presentation of COVID-19 in a preterm infant complicated with sepsis, cytopenia, pneumonia, and severe IVH. The infant in this case was very sick from the time of birth compared with an average appropriate for gestational age of 29 6/7 weeks preterm infant born to a relatively healthy mom. With median incubation period for COVID-19 symptoms around 5 days, no contact with mother postnatally for the first 10 days, significant clinical presentation consistent with COVID-19 in a neonate, persistently positive PCR tests, and positive serology ( ►Figs. 2A, B) , the mode of COVID-19 transmission in this neonate is most likely to be in utero. 4, 6, 7 Maternal consent was obtained to present the case. Different authors in the recent past have tried to present possible cases of vertical transmission of COVID-19 infection, and not necessarily the in utero transmission. Chen et al in a study of nine confirmed COVID-19 pregnant mothers suggested no evidence of vertical transmission. 8 All of the nine infants had negative COVID-19 PCR test and had minimal or mild symptoms, indicating no intrauterine exposure. Zhu et al studied 10 neonates born to mothers with COVID-19 2019-nCoV pneumonia and found that "perinatal 2019-nCoV infection may have adverse effects on newborns, causing problems such as fetal distress, premature labor, respiratory distress, thrombocytopenia accompanied by abnormal liver function, and even death" 9 . The vertical transmission, however, could not be proved. Six out of ten infants in their study were mild to moderately symptomatic with one mortality due to multiorgan failure with no clear diagnosis and all the infants in the study had negative COVID-19 PCR. In Similar to SARS-CoV, antibodies are produced in response to different SARS-CoV-2 antigens, one is outer spike receptor binding domain and the other is inner nucleocapsid. 11 As per the CDC, it may take up to 1 to 3 weeks, or longer postexposure before the antibody is detected in serum. 12 The exact information on the kinetics of COVID-19 is still unclear. IgG antibodies are the only class of immunoglobulins known to crossover to the fetus and are present at birth. 13 IgM antibodies are always neonatal in origin and are detectable usually 1 to 4 weeks postexposure depending upon the disease. 13, 14 IgA antibodies are primarily secretory in nature and are the predominant immunoglobulin isotype present on mucosal surfaces. Most investigators report the initial detection of IgA in mucosal secretions between 1 week and 2 months with peak levels between 4 to 6 weeks of age. 14 Several studies have suggested presence of IgA antibodies in the newborn period to be primarily of fetal origin. 15, 16 The infant's sera in this case on day 13 was strongly positive for both IgG and IgM with a further increase in reactivity on day 18. Day 18 serology (Luminex) showed moderate IgA alongside strongly positive IgG and IgM. Both the serology tests (SARS-CoV-2 ELISA, and Luminex) are Food and Drug Administration approved, and carry specificity of 100% with a sensitivity in high 90s. 17, 18 Placental histopathology findings of villitis, intervillositis, and hemorrhage in the case were also consistent with COVID-19 infection as described recently by Shanes et al. 19 Based on literature as described above, we can safely presume that the exposure to COVID-19 in the infant is most likely intrauterine or preceding the delivery. Limitation of this report is the absence of placental or cord blood for COVID-19 antigen and antibody detection. However, the data on the utility of 2019-nCoV real-time RT-PCR in amniotic fluid, blood, and placenta are very limited. Serologic testing for IgG and IgM is still in the experimental phase and not available for routine diagnosis. Little is also known on the time frame of antibody appearance and the half-life of COVID-19 specific IgG and IgM antibodies especially in infants. COVID-19 is responsible for an unprecedented epidemic in the globalized world, and the infant and childhood infection is still not well known. Though the vertical intrauterine transmission is not proven in the literature yet, we report a case of a vertical neonatal COVID-19 infection. With clinical characteristics, laboratory and serology findings compatible with SARS-CoV-2, this appears be a case of in utero transmission. Further studies looking at in utero transmission are recommended. Neonatal early-onset infection with SARS-CoV-2 in 33 neonates born to mothers with COVID-19 in Wuhan, China Antibodies in infants born to mothers with COVID-19 pneumonia Possible vertical transmission of SARS-CoV-2 from an infected mother to her newborn Initial guidance: management of infants born to mothers with COVID-19 Vertical transmission of coronavirus disease 19 (COVID-19) from infected pregnant mothers to neonates: a review Interim clinical guidance for management of patients with confirmed 2019 novel coronavirus (2019-nCoV) infection The incubation period of coronavirus disease 2019 (COVID-19) from publicly reported confirmed cases: estimation and application Infants born to mothers with a new coronavirus (COVID-19) Clinical analysis of 10 neonates born to mothers with 2019-nCoV pneumonia Can SARS-CoV-2 infection be acquired in utero?: more definitive evidence is needed 2015Coronaviruses: an overview of their replication and pathogenesis Antibody testing for COVID-19 Development of serum antibodies during early infancy in rhesus macaques: implications for humoral immune responses to vaccination at birth Development of mucosal immunity in the first year of life and relationship to sudden infant death syndrome Immunoglobulin A in the epithelium of the respiratory tract and intrahepatic bile ducts of fetuses and newborns with pneumonia and sepsis Placental transfer of maternally-derived IgA precludes the use of guthrie card eluates as a screening tool for primary immunodeficiency diseases Development and evaluation of two SARS-CoV-2 RT-PCR laboratory developed tests on the ARIES® automated, sample-to-answer, real-time PCR system A serological assay to detect SARS-CoV-2 seroconversion in humans Placental Pathology in COVID-19 None declared.