key: cord-1047941-k7zo9ltx authors: Tuttle, Mark K.; Poulin, Marie-France; Sharma, Ravi K.; Ho, Kalon K.L.; Casso-Dominguez, Abel; Guibone, Kimberly; Pinto, Duane S.; Laham, Roger J. title: Lessons for Treating Structural Heart Patients during the COVID-19 Pandemic and Beyond date: 2022-03-21 journal: Struct Heart DOI: 10.1080/24748706.2021.1981561 sha: 150115e1837b079683e3894938ecb638ef5f6700 doc_id: 1047941 cord_uid: k7zo9ltx BACKGROUND: We sought to compare characteristics and outcomes of structural heart disease (SHD) patients treated during the regional peak of the Coronavirus Disease 2019 (COVID-19) pandemic (“COVID era”) compared with historical controls. During the COVID era, elective SHD procedures at Beth Israel Deaconess Medical Center were canceled but urgent cases were still performed. We enacted several practice changes in an effort to minimize complications, prevent COVID transmission, and decrease hospital stay during the pandemic. METHODS: Baseline characteristics and outcomes were collected on all patients who underwent SHD procedures during the COVID era and compared with patients treated during the same time period in 2019. RESULTS: Compared with SHD patients treated during 2019 (N = 259), those treated during the COVID era (N = 26) had higher left ventricular end diastolic pressure (LVEDP; 28 vs. 21 mmHg, p = 0.001), and were more likely New York Heart Association class IV (26.9% vs. 10.0%, p = 0.019), but had a lower rate of bleeding/vascular complications (0% vs. 16.2%, p = 0.013), a lower rate of permanent pacemaker implantation (0% vs. 17.4%, p = 0.019), and a greater proportion of patients were discharged on post-operative day 1 (POD#1; 68.2% vs. 22.2%, p < 0.001). CONCLUSION: Practice changes employed for patients treated during the COVID era were associated with fewer vascular complications, a greater proportion of patients discharged on POD#1, and a lower rate of pacemaker implantation despite more severe illness. As a result, we plan to continue these practices in the post-COVID era. The Coronavirus Disease 2019 (COVID-19) pandemic has had a considerable impact on health-care operations around the world. Hospitals have experienced rises in critically ill patients, increased need for personal protective equipment (PPE), and concerns about overall hospital capacity. In order to care for COVID-19 patients during the pandemic, elective cardiovascular procedures were placed on hold in compliance with government policies, Center for Medicare & Medicaid Services (CMS) recommendations, 1 and major society guidelines. 2 Patients with cardiovascular disease are known to fare worse with COVID-19. 3 However, patients with structural heart disease (SHD) can also face increased morbidity and mortality while awaiting their procedure, particularly if the illness evolves and becomes clinically unstable. 4 To help guide decisions about which patients should undergo a procedure during the COVID-19 pandemic, the American College of Cardiology and the Society for Cardiovascular Angiography and Interventions released a consensus statement to guide triage decisions. 5 This document recommended prioritizing patients with the highest burden of symptoms, particularly patients who were unable to be discharged due to refractory heart failure attributable to their SHD. These considerations all factored into our practice at the Beth Israel Deaconess Medical Center (BIDMC) during the regional peak of the pandemic. We sought to investigate the characteristics of SHD patients treated during the COVID-19 pandemic whose clinical features were felt to be too urgent to defer treatment. We also examined the impact of changes implemented in the care of SHD patients during the peak pandemic at our institution. This investigation is a retrospective cohort study of patients who underwent a transcatheter aortic valve replacement (TAVR) or percutaneous mitral valve intervention (PMVI) at a single tertiary care academic medical center in Boston, Massachusetts, USA, during the first regional peak of COVID-19 pandemic (3/15/ 2020 through 6/1/2020). COVID era patients were compared with SHD patients treated during 2019 at the same institution. During the pandemic, all SHD patients awaiting a procedure were closely monitored by the SHD team through a weekly call and episodic telehealth visits. Patients meeting criteria for an urgent procedure were rapidly identified, referred for a virtual visit to discuss an intervention, and then promptly scheduled. Clinical urgency was determined by the heart team, using such factors as escalating symptoms (New York Heart Association [NYHA] class III-IV), recent hospitalization for acute heart failure or inability to be discharged from the hospital due to heart failure, drop in left ventricular ejection fraction (LVEF), very high aortic transvalvular gradients (mean gradient >60 mm Hg or peak velocity >5 m/s), or syncope. In order to comply with governmental regulations, minimize resource utilization, and protect patients and team members, several other practice changes were implemented in the COVID era. New measures included systematic COVID-19 testing pre-procedure, a separate "clean" hospital entry pathway for COVID negative SHD outpatients (pre-and postprocedure), reduction in the procedural team to only allow essential members in the room, acute recovery of patients in the procedure room by the same team, extended recovery in an isolated COVID-19 area, and early next-day discharge when feasible. In order to ensure adequate hemostasis and early discharge, we began performing routine completion angiograms and vascular ultrasounds in all cases. We reasoned that this would both be beneficial to the patient and also beneficial to staff by preventing a later-manifesting vascular complication that would require a return to the procedure suite/operating room and exposure risk to a second procedure team. For patients with new left bundle branch block or prolonged PR interval without right bundle branch block, instead of prolonged in-hospital monitoring, these patients were discharged with mobile outpatient cardiac telemetry with strict trigger parameters (including drop in heart rate and increase in PR and/or QRS intervals). Next day phone calls were made to all patients to assess their well-being and adjust their medications if needed. Basic demographic data, patient characteristics, procedural details, and in-hospital outcomes were collected. Vascular and bleeding outcomes were reported using the standardized Valve Academic Research Consortium (VARC)-2 6 and Bleeding Academic Research Consortium (BARC) 7 definitions. Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) scores were calculated using the STS website 8 and Transcatheter Therapeutics (TVT) TAVR In-Hospital Mortality Risk scores were calculated using equations from the American College of Cardiology/Transcatheter Therapeutics (ACC/TVT) website. 9 Baseline conduction disease was defined as right or left bundle branch block, sinus node dysfunction, or any degree of AV block. Procedure duration was defined as the difference between the patient's arrival time in the procedure room and the patient's departure time from the procedure room. This study was approved by the hospital's institutional review board; requirement for informed consent was waived. Statistical analysis was performed using JMP/14 software (SAS Institute Incorporated, Cary, North Carolina, USA) and STATA/13 (StataCorp LLC, College Station, Texas, USA). Comparisons of frequencies across categorical variables were done using the Chi-squared test or Fisher's Exact test. Continuous variables were tested for normality using the Shapiro-Wilk method. Non-normally distributed variables were compared using the non-parametric Wilcoxon test. Descriptive statistics of summary data are presented as median [interquartile range] or number (percentage), as appropriate. Since the two groups were numerically unbalanced, we also compared outcomes using a propensity matched analysis with inverse-probability weighting based on age, STS score, gender, NYHA class, high or extreme risk status, LVEF, baseline conduction disease, and serum creatinine ( Table 2 ). There were no differences in STS-PROM score, surgical risk category, TVT predicted in-hospital mortality, baseline conduction disease, LVEF, or mean aortic valve gradient of TAVR patients between COVID era patients and those treated in 2019. There were also no differences in overall length-of-stay, length-of-stay post procedure, or in-hospital mortality among both groups (no in-hospital mortality events in either group). There were fewer patients who experienced a major vascular complication or bleeding event in the COVID era compared with those treated in 2019 (0% vs 16.2%, p = 0.013; Table 1 ). No TAVR patients required a new permanent pacemaker (PPM) in the COVID era, compared with 17.4% during 2019 (p = 0.019; Table 2 ). When matching based on age, STS score, gender, NYHA class, high or extreme risk status, LVEF, baseline conduction disease, and serum creatinine, the differences in these outcomes remained significant across groups (Table 3.) There was no in-hospital mortality in either group. No nosocomial Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) infections were reported among treated patients or SHD team members during the pandemic at our institution. Although patients who underwent an urgent SHD procedure during the COVID era at our institution were more severely ill as demonstrated by higher NYHA classification and higher intraprocedural baseline LVEDP (Figure 1 ), their outcomes were similar to historical controls. Despite more severe illness, those treated during the COVID era had fewer bleeding or vascular complications, and fewer PPM implants, and a greater proportion were discharged on postoperative day 1. When adjusting for age, STS score, gender, NYHA class, high or extreme risk status, LVEF, baseline conduction disease, and serum creatinine, differences in these outcomes remained significant across the two groups. We theorize several reasons for the above findings. With close symptom monitoring, patients needing an urgent procedure were identified adequately and treated before they could clinically decompensate further. Only one death occurred for a patient on the SHD waiting list -this patient had canceled his TAVR in the early COVID era due to fear of nosocomial exposure. A month later, he was admitted for sepsis and expired shortly thereafter (COVID test was negative). Staffing during this time period was also more limited to a smaller group of attending physicians and a single interventional fellow and also from the nursing and technologist side to a smaller group of individuals. A more experienced group of operators and a set of staff more consistently working together than in the historical control period likely contributed to better outcomes. Though we assert that patients had overall higher severity of illness during the COVID era as evidenced by higher LVEDP and a greater proportion of NYHA class IV, they were also slightly younger and this may have contributed to better outcomes. Counterintuitively, procedure duration was longer during the COVID era but radiation exposure was less. This is very likely due to the exclusive use of our hybrid operating room during the COVID era, which has newer and more radiation-efficient X-ray technology. In the historical control group, many of the procedures were performed in an older catheterization laboratory which is less radiation-efficient. Procedure duration may have been longer during the COVID era due to our routine use of completion angiography and ultrasonography. Other potential factors that were unique to the COVID era such as bed availability did not affect procedure times since patients in both groups recovered in a post-procedure area. In anticipation of early discharge, we began performing routine completion angiograms and vascular ultrasounds in all cases prior to departure from the procedure room. While this resulted in slightly higher contrast use than otherwise would be required and was associated with a longer procedure time, this practice led to the absence of any vascular complications or significant bleeding during the COVID era. Some patients had significant peripheral arterial disease, but no alternate access for TAVR was required during the COVID era. Further, the use of outpatient mobile cardiac telemetry for patients at high risk of heart block post TAVR helped minimize the length of stay and was associated with an overall lower PPM rate. Of the seven TAVR patients in the COVID era (31.8%) discharged with mobile cardiac telemetry, two patients were found to require a change in their medications due to slow heart rates or prolonged PR interval on monitoring, but none required a PPM. Our approach to deciding on PPM implantation did not change. The reasons for our lower PPM rate during the COVID era are not entirely clear. It is possible that since a single TAVR team of our most experienced operators practiced during the COVID era, employing the latest techniques (e.g. more stringent use of the cuspoverlap technique for self-expanding valves), implants may have been higher, leading to less impingement on the conduction system. As a result of these favorable outcomes during the COVID era, we have continued utilizing routine completion vascular ultrasonography and outpatient mobile cardiac telemetry since elective procedures have resumed. In addition, the routine use of telehealth, including videoconferencing, enabled us to increase access to care despite being unable to see patients in the ambulatory clinic. We have continued to use this strategy in the post-COVID era for selected patients, particularly those elderly patients who live far away and for whom it is burdensome to travel for an in-person clinic visit. Patients with SHD treated during the COVID era at BIDMC had higher severity of illness compared with those treated during 2019. Despite more severe illness, changes to our clinical protocols were associated with lower rates of vascular complications and an increased proportion of patients discharged the first postoperative day. Because of these improved outcomes, we have continued many of these practices after elective procedures have since resumed. The observational nature of our study limits the causal inference of our practice changes due to possible unmeasured confounding. Despite the use of statistical methodology to adjust for confounders (i.e. inverse-probability weighting), it is likely that there are other unaccounted variables. The impact of COVID on hospital operations, resource availability, and patient selfselection is impossible to fully capture in a statistical model. Center for medicare & medicaid services Catheterization laboratory considerations during the coronavirus (COVID-19) pandemic: from the ACC's Interventional Council and SCAI Comorbidity and its impact on 1590 patients with COVID-19 in China: a nationwide analysis Association between wait time for transcatheter aortic valve replacement and early postprocedural outcomes Triage considerations for patients referred for structural heart disease intervention during the coronavirus disease 2019 (COVID-19) pandemic: an ACC / SCAI consensus statement Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document# Standardized bleeding definitions for cardiovascular clinical trials: a consensus report from the Bleeding Academic Research Consortium Society of Thoracic Surgeons. Online STS risk calculator TAVR in-hospital mortality risk calculator The authors have no funding to report. Mark Tuttle, Marie-France Poulin, Kalon Ho, Abel Casso-Dominguez, Kim Guibone, Ravi Sharma: No conflicts of interest to disclose. Duane Pinto: Receives consulting fees from Abiomed, AbbottVascular, Boston Scientific, Magenta, Medtronic, NuPulseCV, and Teleflex. Roger Laham: Receives proctoring fees from Edwards and Medtronic.