key: cord-1045025-js167loa authors: Meggiolaro, Maira N.; Roeber, Florian; Kobylski, Victoria; Higgins, Damien P.; Šlapeta, Jan title: Comparison of multiplexed-tandem real-time PCR panel with reference real-time PCR molecular diagnostic assays for detection of Giardia intestinalis and Tritrichomonas foetus in cats date: 2019-01-06 journal: Vet Parasitol DOI: 10.1016/j.vetpar.2018.12.009 sha: b565209d3d02d6defebda91d621eddbcd0a7611e doc_id: 1045025 cord_uid: js167loa Giardia intestinalis and Tritrichomonas foetus are frequent enteric protozoan parasites of the gastrointestinal track of domestic cats. Because of different treatment options for the parasites, confirmation of presence of one or both pathogens is necessary. The PCR based assays are suitable for differential diagnosis. We evaluated the performance of Small Animal Diarrhoea panel, a multiplexed-tandem real-time PCR (MT-PCR) assay, that detects DNA of both G. intestinalis and T. foetus. The sensitivity and specificity were compared to reference real-time PCR assays using 105 faecal samples, 39.05% (n = 41) positive for G. intestinalis and 30.48% (n = 32) were positive for T. foetus. The faecal samples positive for T. foetus had a high proportion of late amplifiers, determined by an arbitrary threshold of C(t)-values > 35. On the other hand, only one G. intestinalis positive sample was considered a late amplifier. For G. intestinalis DNA, the MT-PCR assay had 95.1% sensitivity and 92.1% specificity. For T. foetus DNA, the MT-PCR assay had 41.9% sensitivity and 100.0% specificity. To evaluate the interlaboratory reproducibility of the MT-PCR assay, results were compared in two different laboratories and found to be in a very good agreement (Kappa = 0.9). Further analysis of the DNA using conventional PCR determined presence of G. intestinalis Assemblage F and T. foetus genotype ‘feline’. In conclusion, the MT-PCR Small Animal Diarrhoea panel had a good and poor performance against reference assays for G. intestinalis and T. foetus, respectively. The assay is suitable for detection and differential diagnosis of G. intestinalis and moderate to high burdens of T. foetus in small animal clinical practice. Giardia intestinalis and Tritrichomonas foetus are frequent and ubiquitous enteric protozoans affecting domestic cats (Gookin et al., 2017; Gruffydd-Jones et al., 2013; Šlapeta et al., 2015) . Both parasites have a world-wide distribution in owned cats (Feng and Xiao, 2011; Yao and Koster, 2015) . While G. intestinalis is a well-known parasite of the small intestine, and veterinarians are familiar with the disease giardiasis, T. foetus is considered to be an emerging infection (Gookin et al., 2017; Gruffydd-Jones et al., 2013) . Infection with T. foetus is associated with outbreaks of large bowel diarrhoea in < 2 year old cats, yet the epidemiology is not fully understood (Gookin et al., 2004; Hale et al., 2009; Van der Saag et al., 2011) . Both feline giardiasis and trichomonosis present clinically in young animals, with the most consistent clinical sign being diarrhoea (Gookin et al., 2017 (Gookin et al., , 2004 . Often, both parasites are present as co-infection (Bell et al., 2010) . Because of different treatment options for each disease, confirmation of presence of one or both pathogens is necessary (Bell et al., 2010; Gookin et al., 2006; Gunn-Moore and Lalor, 2011; Šlapeta et al., 2010) . For G. intestinalis the in-clinic rapid diagnostic coproantigen assays are ideal, with extremely good sensitivity and specificity, and are therefore preferred for in-clinic diagnosis (Barbecho et al., 2018; Uiterwijk et al., 2018) . However, no in-clinic rapid diagnostic coproantigen assay is available for T. foetus, therefore alternative tests need to be requested or undertaken. Faecal morphological examination is a good option; nevertheless, its sensitivity for both G. intestinalis and T. foetus are mediocre (Bell et al., 2010; Gookin et al., 2017) . The most suitable approaches are molecular PCR based assays with verified high sensitivity and specificity (Gookin et al., 2017) . PCR based assays in the form of PCR panels are becoming established tools in veterinary practice. On one hand, they are not in-clinic tests, but turnaround of 1-3 days makes them suitable as part of differential diagnostics in diarrhoea in young cats. Validation and cross validation between laboratories are urgently needed to elucidate the reliability of PCR panels to recognise their limitation and performance against set of reference assays. The aim of this study was to evaluate the performance of a multiplexed-tandem real-time PCR (MT-PCR) assay for G. intestinalis and T. foetus on feline DNA samples with presence of G. intestinalis and T. foetus determined previously using reference real-time PCR assays. To evaluate the reproducibility of the MT-PCR assay, results were compared in two different laboratories. A total of 105 feline faecal samples submitted to the Veterinary Pathology Diagnostic Services, Sydney School of Veterinary Science (VPDS) during 2017 for diagnostic purposes were used. All samples were collected in sterile containers, without preservatives, and left in 4°C for not longer than 4 days before DNA isolation. Approximately 0.25 g of each faecal sample was added into tubes with glass beads and lysis buffer and then homogenised and disrupted using the high-speed homogeniser, FastPrep® 24 (MP Biomedicals, Australia) at setting 6.0 m/s for 40 s. A magnetic bead based nucleic acid isolation kit, MagAttract Power Microbiome DNA/RNA Kit (27600-4-KF, Qiagen, Australia), adapted for the KingFisher™ Duo (Thermo Scientific™, Australia) was utilised for all DNA isolations. The DNA/ RNA was eluted in 100 μL of DNA/RNA free water, following manufacturer protocol. Each batch of 12 samples included one blank control, to monitor for the presence of contamination. Two different versions of the proprietary MT-PCR technology (AusDiagnostics, Australia) were used for the experiments which were (A) High-Plex 24 (Cat.: 9150), consisting of a MT-Processor (liquidhandling system) (AusDiagnostics, Australia) in conjunction with a 384well real-time PCR thermocycler (DT-Prime real-time PCR detection system) (DNA-Technology, Russia) and permitting 24 samples to be tested per run, and (B) Mini-Plex 12 (Cat.: 9350), consisting of a MT-Processor (liquid-handling system) (AusDiagnostics, Australia) in conjunction with a 96-well real-time PCR thermocycler (CFX96™ real-time PCR detection system) (Biorad, Australia) and permitting 6 samples to be tested per run. Samples were tested on the High-Plex instrument using the Small Animal Diarrhoea -HP 16-well (Cat.: 28174) test panel, or the in the Mini-Plex 12 system, using the Small Animal Diarrhoea -MP 16-well (Cat.: 78174) test panel. For the specific amplification of G. intestinalis the 18S gene of nuclear ribosomal DNA was targeted and for T. foetus the cysteine protease gene was used. The pathogen targets in both panel versions were identical. This assay includes an initial multiplexed short amplification followed by a single-target amplification, using SYBR Green chemistry. It tests for 14 targets: Campylobacter spp., Dientamoeba fragilis, Salmonella spp., G. intestinalis, Cryptosporidium, T. foetus, Toxoplasma gondii, parvovirus/panleukopenia virus, canine distemper virus, canine coronavirus, feline coronavirus, Clostridium perfringens, Clostridium perfringens enterotoxin (CPE) and Neospora caninum. It includes a reference PCR targeting a mammalian gene to test for sample adequacy and an artificial sequence (SPIKE) to check for the presence of inhibitors. The setup procedure in both MT-PCR system versions was as followed: In the first step, 50 μl reaction volumes containing Step 1 RNA mastermix (AusDiagnostics, Cat. 40340RNA), oil and 10 μL of each isolated DNA/RNA was subjected to 15 cycles in the MT-Processor (AusDiagnostics, Australia). After cycling, samples were automatically diluted and aliquoted by the MT-Processor into a 384 well plate (for High-Plex) or a 96 well plate (for Mini-Plex), supplied in the kit, containing step 2 primers for each target. The plate was then transferred to the specific real-time thermocycler and amplification conditions were 95°C for 10 min, followed by 30 cycles of 95°C for 10 s, 60°C for 15 s and 72°C for 30 s A melt curve was generated at the end from 72°C to 94.8°C at 0.4°C intervals and analysed using the Easy-Plex results software (AusDiagnostics, Australia). A sample was recorded as test-positive using the 'auto-call function' of the Easy-Plex software, if the amplicon produced a single melting curve which was within 1.5°C of the expected melting temperature, the height of the peak was higher than 0.2 dF/dT and the peak width was ≤ 3.8°C (AusDiagnostics, Australia). Cycle threshold (C t -values) and take-off values were recorded for each test-positive sample, and quantitative values for each parasite in each sample were determined using an automated comparison with C t -values data determined for an internal spike-control (SPIKE; tube containing 10,000 copies of a synthesized oligonucleotide template and a specific primer set) for each sample tested (Stanley and Szewczuk, 2005) . Each sample was also tested for the presence of amplifiable nucleic acids (i.e. extraction control) using a vertebrate reference gene (NONO). A total of 105 samples were tested at a Laboratory A (AusDiagnostics) using the High-Plex 24 system (Cat.: 9150) and a subsample (64 samples) was tested at a Laboratory B (VPDS) on the smaller Mini-Plex 12 system (Cat.: 9350). The number of samples tested per run was either 9-24 or 1-5 plus a blank control on the High-Plex and the Mini-Plex system, respectively. All samples (n = 105) were tested in duplicate for G. intestinalis realtime PCR using previously described primers and TaqMan probe, (S0799) Giardia-80 F (5′-GAC GGC TCA GGA CAA CGG TT-3′), (S0801) Giardia-127R (5′-TTG CCA GCG GTG TCC G-3′), and (S0800) Giardia-105 T (6-HEX-5′−CCC GCG GCG GTC CCT GCT AG-3′-BHQ1) (Verweij et al., 2003) . The TaqMan real-time PCR assay targets a 62-bp fragment of SSU RNA gene of G. intestinalis (GenBank accession no. M54878) (Verweij et al., 2003) . The G. intestinalis-specific primers and probe were obtained from Macrogen (Korea). Amplifications were performed with SensiFAST™ Probe No-ROX Kit (BIO-86005, Bioline, Australia) in a total volume of 20 μL per reaction, where the final concentration for primers and probe was 400 nM and 100 nM respectively plus 2 μL of template. The real-time PCR conditions were as follows: 95°C for 3 min, followed by 40 cycles of 95°C for 10 s, 60°C for 20 s on a CFX96 Touch™ Real-Time PCR Detection System (BioRad, Australia) and analysed using BioRad CFX Manager (BioRad, Australia). Each PCR run included known positive control as well as negative control. Positive results were determined if both repeats yielded satisfactory cycle threshold (C t ) values (C t -values < 38.00). Suspect positive results were determined if one or more repeats yielded C t -values ≥ 38.00 and negative results were determined if both repeats did not cross the threshold (C t -values > 40). All samples (n = 105) were tested in duplicate for T. foetus real-time PCR using previously described primers and TaqMan-MGB probe (S0820), TFF2 (5′-GCG GCT GGA TTA GCT TTC TTT-3′), TFR2 (5′-GGC GCG CAA TGT GCA T-3′) and TRICHP2 (6-FAM-5′-ACA AGT TCG ATC TTT G-MGB-BHQ) (McMillen and Lew, 2006) . The T. foetus-specific primers and probe were obtained as a premix from Life Technologies (Australia). Amplifications were performed with SensiFAST™ Probe No-ROX Kit (BIO-86005, Bioline, Australia) in a total volume of 20 μL per reaction, where the final concentration for primers and probe was 450 nM and 125 nM respectively, plus 2 μL of template. The real-time PCR conditions were as follows: 95°C for 3 min, followed by 40 cycles of 95°C for 20 s, 60°C for 45 s on a CFX96 Touch™ Real-Time PCR Detection System (BioRad, Australia) and analysed using BioRad CFX Manager (BioRad, Australia). Each PCR run included known positive control as well as negative control. Positive results were determined if both repeats yielded satisfactory cycle threshold (C t ) values (C t -values < 38.00). Suspect positive results were determined if one or more repeats yielded C t -values ≥38.00 and negative results were determined if both repeats did not cross the threshold (C t -values > 40). A multiplexed assay including both real-time PCR assays for G. intestinalis or T. foetus was tested using a subset of 31 samples. All assays were run in duplicate in a duplex assay using a SsoAdvanced Universal Probes Supermix (Bio-Rad, Australia). Primers and probes concentrations and template volume were kept the same as above. The real-time PCR conditions were as follows: 95°C for 3 min, followed 40 cycles of 95°C for 20 s, 60°C for 45 s on a CFX96 Touch™ Real-Time PCR Detection System (BioRad, Australia) and analysed using BioRad CFX Manager (BioRad, Australia). Positive results were determined if both repeats yielded satisfactory cycle threshold (C t ) values (C t -values < 38.00). Suspect positive results were determined if one or more repeats yielded C t -values ≥ 38.00 and negative results were determined if both repeats did not cross the threshold (C t -values > 40). Giardia intestinalis assemblage identification was determined using primers amplifying GDH and SSU rRNA gene (Feng and Xiao, 2011) . To amplify GDH we used GDH1/GDH2 followed by nested primers GDH3/ 4. To amplify SSU rDNA we used RH11/RH4 followed by nested primers GiarF/GiarR. Oligonucleotides were synthesised by Macrogen Inc. (Seoul, Korea). All PCRs used MyTaq Red Mix (BioLine, Australia) in a final volume of 30 μL where the final concentration for primers was 500 nM plus 2 μL of DNA template. The secondary PCR used 1 μL of the primary PCR. Both nested PCR reactions were run in a T100 PCR cycler (BioRad, Australia). All PCRs were run with a negative control of sterile PCR-grade water. PCR products that yielded an unambiguous single band product of the expected size in 1.5% (w/v) agarose were purified and then directly and bidirectionally sequenced using amplification primers at Macrogen Inc. (Seoul, Korea). All sequences were assembled and aligned with reference sequences representing G. intestinalis assemblage A-H using CLC Main Workbench 6.9.1 (CLC bio, a QIAGEN Company, Denmark). Determination of T. foetus genotype was evaluated using PCR amplification of the ITS rDNA region based on primers TFR3/TFR4 as previously described (Felleisen et al., 1998; Šlapeta et al., 2012) . Oligonucleotides were synthesised by Macrogen Inc. (Seoul, Korea). All PCRs used MyTaq Red Mix (BioLine, Australia) in a final volume of 30 μL where the final concentration for primers was 500 nM plus 2 μL of DNA template. PCR reactions were run in T100 PCR cycler (BioRad, Australia). All PCRs were run with a negative control of sterile PCRgrade water. PCR products that yielded an unambiguous single band product of the expected size in 1.5% (w/v) agarose were purified and then directly and bidirectionally sequenced using amplification primers at Macrogen Inc. (Seoul, Korea). All sequences were assembled, aligned with reference sequences representing T. foetus genotype and analysed using CLC Main Workbench 6.9.1 (CLC bio, a QIAGEN Company, Denmark). Sensitivity and specificity were calculated using 2 × 2 tables using test assay and reference assay considered to determine 'true' positives. Specificity was calculated as: number of true negatives / (number of true negatives + number of false positives). Sensitivity was calculated as: number of true positives / (number of true positives + number of false negatives). The test strength agreement was calculated using Kappa, standard error (SE) and 95% confidence interval (95%CI) (www.graphpad.com/quickcalcs/). One sample was inhibited from the original 105 samples, as determined by the SPIKE control, and did not yield any positive result, and thus was excluded. All samples (n = 104) were tested at Laboratory A (AusDiagnostics) using the High-Plex 24 platform. Out of 104 samples, 44 (42.31%) and 13 (12.50%) tested positive for G. intestinalis and T. foetus, respectively. In addition, FCoV, FPV, Clostridium perfringens, Campylobacter spp. and Salmonella spp. were detected using the Small Animal Diarrhoea panel (Table 1 ). The average melt temperature for the produced amplicons was 92.60°C (SD: 0.39) for G. intestinalis and 80.12°C (SD: 0.17) for T. foetus. To evaluate the reproducibility of results obtained with the Small Animal Diarrhoea panel between two different MT-PCR systems and the two different laboratories, a subsample of 64 samples was compared in Laboratory A and Laboratory B (VPDS) (Supplementary Data). Twenty three (23/64) were called positive for G. intestinalis by both laboratories and additional three samples were positive for G. intestinalis in Laboratory A (estimated target concentration 28, 35 and 11). For T. foetus, five samples (5/64) were called positive in both laboratories, and additional one was considered positive by Laboratory B (estimated target concentration was not determined). All remained samples were negative for either G. intestinalis and/or T. foetus. The test strength agreement between the two laboratories for both G. intestinalis and T. foetus was 'very good' (Kappa = 0.900, SE 0.098, 95%CI: 0.708-1.000; Kappa = 0.900, SE 0.056, 95%CI: 0.790-1.000). To determine sensitivity and specificity of the MT-PCR for G. intestinalis, a previously described G. intestinalis TaqMan real-time PCR was used as the reference assay. All samples (n = 105) were tested in duplicate and 39.05% (95%CI: 30.25%-48.62%; n = 41) had threshold (C t Data). The MT-PCR from Laboratory A for G. intestinalis had 95.1% sensitivity and 92.1% specificity; n = 105, one samples was inhibited (Table 2 ). If those samples that were automatically called as 'check' in MT-PCR (Laboratory A) were considered negative, the sensitivity was 82.9% and specificity was 98.4%. The MT-PCR from Laboratory B for G. intestinalis had 85.2% sensitivity and 100.0% specificity (n = 64). If those samples that were automatically called as 'check' in MT-PCR (Laboratory B) were considered negative, the sensitivity was 74.1% and specificity was 100.0%. To determine sensitivity and specificity of the MT-PCR for T. foetus, a previously described T. foetus real-time TaqMan-MGB PCR was used as the reference assay (Fig. 1) Fig. 1A) . The MT-PCR from Laboratory B for T. foetus had 35.0% sensitivity and 100.0% specificity (n = 64). If those samples that were automatically called as 'check' in MT-PCR (Laboratory B) were considered negative, the sensitivity was 20.0% and specificity was 100.0%. To evaluate the opportunity to multiplex the G. intestinalis with T. foetus in-house assays, we selected 21 G. intestinalis and 20 T. foetus samples based on single assay result above; ten of these samples overlapped because they were positive for both parasites (Supplementary Data). Samples positive for G. intestinalis had average C t -values of 26.33 (min. 20.36, max. 33.30 ) and 52% (11/21) of them were negative for T. foetus. Samples positive for T. foetus had average C t -values of 31.90 (min. 25.27, max. 37.32) and 50% (10/20) of them was negative for G. intestinalis. The multiplex assay returned positive result for G. intestinalis in all 100% samples (n = 21; C t -values of 28.24, min. 20.51, max. 36.65), that previously tested positive for G. intestinalis using a non-multiplexed assay. The multiplex assay returned positive result for T. foetus in 85% samples (n = 17; C t -values of 30.18, min. 25.28, max. 38.27 ) that tested positive for T. foetus using a non-multiplexed assay. Three samples that returned negative results for T. foetus were those that had a very high C t -value for T. foetus in an independent assay (average 37.04, min. 36.32, max. 37.32) and were negative for G. intestinalis. The R 2 (square of the Pearson correlation coefficient) for C t -values between the G. intestinalis and T. foetus assays compared to multiplexed assay was 0.83 and 0.56, respectively. Seven G. intestinalis real-time PCR positive samples were further analysed to determine G. intestinalis assemblage. Using amplification of GDH and SSU rDNA, we determined that all belonged to Assemblage F of G. intestinalis. The GDH sequence (487 nt, excluding amplification primers) was 100% identical to a reference gene sequence (EF507597). The SSU rDNA sequence (139 nt, excluding amplification primers) was 100% identical to a reference gene sequence (AF199444), however at this locus and sequenced region, the Assemblage A and Assemblage F of G. intestinalis are identical. Seven T. foetus real-time PCR positive samples were further analysed to determined T. foetus genotype. The ITS rDNA region (297 nt, excluding amplification primers) was 100% identical to a reference sequence (JX187001) from T. foetus genotype 'feline'. In small animal practice, G. intestinalis is often recognised as the most frequently detected enteric parasite (Bouzid et al., 2015; Palmer et al., 2008) . The prevalence ranges between 0-30% and this frequency of detection is highlighted by G. intestinalis prominent place in diagnostic PCR faecal panels offered to veterinarians by diagnostic laboratories (Feng and Xiao, 2011; Gizzi et al., 2014; Gruffydd-Jones et al., 2013; Ito et al., 2016; Koehler et al., 2014; Symeonidou et al., 2018; Tysnes et al., 2014) . Faecal PCR panels become a convenient approach for veterinarians, enabling cost effective detection of multiple pathogens simultaneously (Gizzi et al., 2014; Laude et al., 2016; Stanley and Szewczuk, 2005; Stark et al., 2011) . The MT-PCR Small Animal Diarrhoea panel was revalidated between two laboratories and against single-plex assays for two main pathogens relevant in differential diagnostics in feline medicine. Both G. intestinalis and T. foetus are known to be associated with each other, yet the mainstream drug for G. intestinalis, metronidazole, is not efficacious for T. foetus (Bell et al., 2010; Gookin et al., 2017 Gookin et al., , 2007 . The performance of the MT-PCR Small Animal Diarrhoea panel for G. intestinalis was in good agreement, with excellent sensitivity and specificity compared to the TaqMan assay. The original G. intestinalis assay was validated for the human G. intestinalis Assemblage A and B (Stark et al., 2011; Verweij et al., 2003) . Our study demonstrates that the assay is equally specific for the feline G. intestinalis Assemblage F, because all feline samples in this study that were genotyped were confirmed as G. intestinalis Assemblage F -the genetically defined subgroup specific for cats (Feng and Xiao, 2011) . In clinical diagnostics the G. intestinalis assemblage is not determined for cat, dog or human samples (Gizzi et al., 2014; Madison-Antenucci et al., 2016; Stark et al., 2014; Verweij et al., 2004) . Most research studies have demonstrated G. intestinalis Assemblage F being shed by cats; only in exceptional circumstances were the zoonotic G. intestinalis Assemblages A and B detected (Feng and Xiao, 2011; Gruffydd-Jones et al., 2013) . Therefore, isolates of G. intestinalis causing disease in cats are not considered zoonotic (Gruffydd-Jones et al., 2013) . In several circumstances, the G. intestinalis call by the automated profile of the MT-PCR Small Animal Diarrhoea panel indicated ambiguity and requested the operator to check the result. A large proportion of such ambiguous G. intestinalis results were positive in the single-plex G. intestinalis reference assay, enabling adjustments of the automatic call parameters. Unlike the G. intestinalis PCR performance, the T. foetus component of the MT-PCR Small Animal Diarrhoea had only poor sensitivity but perfect specificity compared to the reference TaqMan-MGB assay. These differences in the sensitivity are likely the result of the different target genes used by the assays. The TaqMan-MGB assay uses an ITS-1 target, which is multi-copy gene and repeated several times in the genome of the parasite, whereas the MT-PCR assay for T. foetus uses the cysteine protease gene which is a single-copy gene. Diagnostics of T. foetus is difficult because of its poorly understood pathogenesis, intermittency and load of T. foetus shedding (Gookin et al., 2017) . The faecal samples positive for T. foetus had a high proportion (53%, 16/30) of late amplifiers, determined by an arbitrary threshold of C t -values > 35. On the other hand, only one (2%, 1/41) G. intestinalis positive sample was considered a late amplifier (C t -values > 35). Such a high proportion of late amplifying samples positive for T. foetus suggests the low numbers of T. foetus in given samples reached the limit of detection for the T. foetus assay (McMillen and Lew, 2006) . High sensitivity for T. foetus is desired in a clinical situation, where the aim is to quarantine or eliminate the pathogens from individual cat or a cattery. Verification of elimination of T. foetus post treatment should be compulsory, however, the probability of undetected occult T. foetus shedders may contribute to the maintenance of T. foetus in the cat populations, because multiple PCR tests are prohibitive for cat owners due to cost associated with such PCR testing. Availability of probe-based assays for both G. intestinalis and T. foetus enables multiplexing for simultaneous detection. Both published assays have been validated and are considered reference assays (McMillen and Lew, 2006; Verweij et al., 2003) . The G. intestinalis assay has previously been implemented in a multiplex assay targeting human enteric pathogens with exceptional sensitivity and specificity in clinical samples (Verweij et al., 2004) . Our multiplexed assay confirms exceptional performance of the G. intestinalis, yet highlights the difficulties with detection of T. foetus. In conclusion, the MT-PCR Small Animal Diarrhoea had a good and poor performance against reference assays for G. intestinalis and T. foetus, respectively. The assay is suitable for detection of G. intestinalis and moderate or higher burdens of T. foetus. To allow for the detection of low-level T. foetus infections an ITS based assay may provide the better alternative to the cysteine protease gene. FR, VK were employees of AusDiagnostics, Australia. Comparative performance of reference laboratory tests and in-clinic tests for Giardia in canine feces Naturally occurring Tritrichomonas foetus infections in Australian cats: 38 cases The prevalence of Giardia infection in dogs and cats, a systematic review and meta-analysis of prevalence studies from stool samples Detection of Tritrichomonas foetus by PCR and DNA enzyme immunoassay based on rRNA gene unit sequences Zoonotic potential and molecular epidemiology of Giardia species and giardiasis Presence of infectious agents and co-infections in diarrheic dogs determined with a real-time polymerase chain reaction-based panel Prevalence of and risk factors for feline Tritrichomonas foetus and Giardia infection Efficacy of ronidazole for treatment of feline Tritrichomonas foetus infection Efficacy of tinidazole for treatment of cats experimentally infected with Tritrichomonas foetus The conundrum of feline trichomonosisthe more we learn the 'trickier' it gets Giardiasis in cats: ABCD guidelines on prevention and management Treatment of diarrhoea in cats caused by Tritrichomonas foetus Prolonged resilience of Tritrichomonas foetus in cat faeces at ambient temperature Prevalence of intestinal parasites in breeding cattery cats in Japan Giardia/giardiasis -a perspective on diagnostic and analytical tools Is real-time PCR-based diagnosis similar in performance to routine parasitological examination for the identification of Giardia intestinalis, Cryptosporidium parvum/Cryptosporidium hominis and Entamoeba histolytica from stool samples? Evaluation of a new commercial multiplex PCR assay and literature review Multicenter evaluation of BD Max Enteric Parasite Real-Time PCR assay for detection ofGiardia duodenalis, Cryptosporidium hominis, Cryptosporidium parvum, and Entamoeba histolytica Improved detection of Tritrichomonas foetus in bovine diagnostic specimens using a novel probe-based real time PCR assay National study of the gastrointestinal parasites of dogs and cats in Australia Tritrichomonas foetus from domestic cats and cattle are genetically distinct Comparative analysis of Tritrichomonas foetus (Riedmüller, 1928) cat genotype, T. Foetus (Riedmüller, 1928) cattle genotype and Tritrichomonas suis (Davaine, 1875) at 10 DNA loci Differences in the faecal microbiome of non-diarrhoeic clinically healthy dogs and cats associated with Giardia duodenalis infection: impact of hookworms and coccidia Evaluation of multiplex tandem real-time PCR for detection of Cryptosporidium spp., Dientamoeba fragilis, Entamoeba histolytica, and Giardia intestinalis in clinical stool samples Evaluation of the EasyScreen enteric parasite detection kit for the detection of Blastocystis spp., Cryptosporidium spp., Dientamoeba fragilis, Entamoeba complex, and Giardia intestinalis from clinical stool samples Feline gastrointestinal parasitism in Greece: emergent zoonotic species and associated risk factors Subclinical Giardia in dogs: a veterinary conundrum relevant to human infection Cat genotype Tritrichomonas foetus survives passage through the alimentary tract of two common slug species Real-time PCR for the detection of Giardia lamblia Simultaneous detection of Entamoeba histolytica, Giardia lamblia, and Cryptosporidium parvum in fecal samples by using multiplex real-time PCR Tritrichomonas foetus infection, a cause of chronic diarrhea in the domestic cat The authors wish to thank Nichola Calvani and Katrina Gilchrist (University of Sydney) for providing excellent technical help. This work was funded in part by the Veterinary Pathology Diagnostic Services, University of Sydney. The DNA analysis in laboratory A (AusDiagnostics, Australia) was provided pro bono. AusDiagnostics, Australia had no role in decision to publish. Supplementary material related to this article can be found, in the online version, at doi:https://doi.org/10.1016/j.vetpar.2018.12.009.