key: cord-1044261-adpjsx1y authors: Sahiledengle, B.; Tekalegn, Y.; Bekele, K.; Tesemma, A.; Edward Quisido, B. J. title: Stethoscope and Non-Infrared Thermometer Disinfection among Physicians: A Cross-Sectional Study with Implications for the Control of COVID-19 date: 2020-08-15 journal: nan DOI: 10.1101/2020.08.14.20174433 sha: 78c60d67a57fa33585a414174b9f3fff19bc80ac doc_id: 1044261 cord_uid: adpjsx1y Background: Stethoscopes and non infrared thermometers are the customary medical equipment used by the physicians on a daily basis, among various patients. With the rise of potential infections in the healthcare facilities and the transmission nature of the current volantly evolving COVID 19, consistent and correct disinfections of these devices after each use should not be pardoned. This study, therefore, describes the level of stethoscope and non infrared thermometer disinfection practices among physicians and determines its associated factors during the COVID 19 pandemic. Methods: A nationwide cross-sectional online survey was circulated using an anonymous and self-reporting questionnaire via Google form with a consent form appended to it. Results: Four hundred twenty-two physicians participated (62.80% medical doctors, 33.65% seniors, and 3.55% residents). The proportion of stethoscope and non Infrared thermometer disinfections after every use was 13.9% (95%CI: 10.9-17.6) and 20.4% (95%CI: 16.7-24.5), respectively. In adjusted analyses, taking COVID-19 training (Adjusted Odds Ratio [AOR]: 2.52; 95% [Confidence Interval (CI)]: 1.29-4.92) and the availability of stethoscope disinfection materials at the workplace (AOR: 3.03; 95% CI: 1.29-7.10) were significantly increased the odds of stethoscope disinfection after every use. The odds of stethoscope disinfection after every use was significantly decreased for those who reported the use of shared stethoscope (AOR: 0.34; 95% CI: 0.12-0.92). Among the physicians, disinfection after every use was significantly higher in resident physicians compared to those of general practitioners for both stethoscope (AOR: 4.61; 95%CI: 1.29-16.52) and non Infrared thermometers (AOR: 7.10; 95%CI: 2.30-21.95). Conclusion: Only a wee share of the respondents reported that they have disinfected their stethoscopes and non-infrared thermometers after every use possibly jeopardizing both patients and clinicians safety, particularly during the COVID 19 pandemic and these results must be sternly dealt with. Provisions of training and securing constant and available stethoscope disinfection supplies can significantly increase disinfection practices among the physicians after every use. These simple interventions could be replicated by other healthcare facilities. Dependent Variables 1 4 0 In the physicians' self-report regarding stethoscope and non-infrared thermometer disinfection practices, 1 4 1 respondents were posed to specify their usual practices by uttering to them "How often do you disinfect your 1 4 2 stethoscope?". Physicians who claimed that they have disinfected their stethoscopes after every use/after contact 1 4 3 with patients earned them a score of "1" and labeled as "disinfection after every use". On the other hand, whether 1 4 4 anyone claimed that they practiced "monthly", "weekly", "Once a week or less often", "Multiple times per week but 1 4 5 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 15, 2020. . https://doi.org/10.1101/2020.08.14.20174433 doi: medRxiv preprint not every day", "Once or twice a day", and "Multiple times per day but not after every use" bases, did not earn 1 4 6 them any score and were tagged "0". Similarly, physicians who have claimed that they have disinfected non-1 4 7 infrared thermometers after every use were awarded one point, and zero, if otherwise. We categorize the 1 4 8 responses about frequency of non-infrared thermometer disinfection as "after every use" versus all other 1 4 9 responses as "not after every use". The independent variables include gender, age, years of service, type of healthcare facility, availability of Completed questionnaires were extracted from Google Forms in Excel spreads and were exported to STATA 1 5 7 version 14.0 for the analyses. Descriptive statistics were employed to illustrate the data. Multiple binary logistic 1 5 8 regression models were used to assess the independent predictors of the outcome variables (stethoscope and 1 5 9 non-infrared thermometer disinfection after every use). All the independent variables were tested for potential 1 6 0 multicollinearities before placing them in the multivariable logistic regression models. The multicollinearity effects 1 6 1 were assessed with a cut of off point of variation inflation factor (VIF) of greater than ten. Finally, significant 1 6 2 variables were discerned based on the adjusted odds ratio (AOR) with 95% Confidence Intervals (CIs), and The study was conducted according to the Declaration of Helsinki. Ethical approval was granted by the anonymously, voluntarily, and independently. The privacy and confidentiality of the study participants were also 1 6 9 safeguarded throughout the data collection. An information letter was incorporated on the first page of every 1 7 0 questionnaire which covered information about the study description, eligibility criteria, voluntary participation, and 1 7 1 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted August 15, 2020. . https://doi.org/10.1101/2020.08.14.20174433 doi: medRxiv preprint confidentiality. Also, the contact details of the investigators (name, phone number, email address, and their 1 7 2 affiliations) for any inquiry were mounted on the top of the questionnaire. All participants were assumed to only 1 7 3 proceed on the survey after reading the consent and acknowledging engagement. Accordingly, electronic 1 7 4 informed consent was sought from the study participants as pre-requisites before they are able to annex the is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 15, 2020. As seen in Table 2 , the proportion of stethoscope disinfection after every use was 13.9% (95%CI: 10.9-17.6). A 1 9 0 quarter of the physicians delineated that they never disinfected their stethoscopes. Fifty-four percent of them also physicians outlined that they cried out for access to stethoscope disinfectants when needed. Factors, such as 1 9 6 forgetfulness (29.3%) and negligence (25.2%) were the frequently cited barriers to such. Nevertheless, 1 9 7 378(89.57%) of respondents believed that stethoscopes necessitated to be disinfected after every use. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 15, 2020. . Factors associated with stethoscope disinfection after every use 2 0 6 The odds ratios for a unit change on each covariate are delineated thru the binary logistic regression model in 2 0 7 is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 15, 2020. . Three hundred sixty-six respondents, 86.73% concurred that the non-Infrared thermometers need to be . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 15, 2020 In order to scrutinize on the stethoscope and non-infrared thermometer disinfections, an online nationwide survey correct stethoscope disinfection should be observed after each use on patients [5, 40] , Upholding to the core 2 5 6 values of nonmaleficence, physicians should be more diligent in providing safe domains for their patients. To our cognizance, no specific guidelines solely on stethoscopes disinfection are available to date. The novelty of 2 5 8 this pandemic -along with its uncertainties -makes it critical for health authorities to develop appropriate such as stethoscopes, should be disinfected once daily or weekly [29] . The above standards might not be 2 6 3 reflective on the current danger that a contaminated stethoscope may feasibly jeopardize patients' and 2 6 4 physicians' safety -given the survival potential of coronavirus to thrive on different surfaces for an extended 2 6 5 period of time [32] . It has been reported that SARS-CoV-2 can survive on steel and plastic surfaces for 72 hours 2 6 6 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 15, 2020. . or more [41] . Additionally, stethoscopes have high usance for assessment of COVID-19 patients [42, 43] , and 1 5 concomitant execution of clinical examination and lung imaging at the bedside by the same doctor [43] . However, 2 9 5 in resource-limited settings, this may not be applicable. It is, therefore, of utmost importance that ensuring the 2 9 6 availability of disinfectant solutions may precede a positive influence on disinfection compliance. Patel et al also 2 9 7 argued that, at this point, it is difficult to answer if the stethoscope is a necessary tool or an unnecessary evil sharing of personal items have been described by WHO [34] . The researchers also believe that, if unavoidably 3 0 7 stethoscopes are shared, it is paramount to disinfect the stethoscopes meticulously. Lastly, another fact but not of This study has a number of limitations. Whilst, one of the strengths of the study is that the analysis of the CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted August 15, 2020. . https://doi.org/10.1101/2020.08.14.20174433 doi: medRxiv preprint Conclusion 3 2 4 In summary, less than a fifth of the physicians disinfected their stethoscopes after every use, and a significant 3 2 5 number of respondents reported that they have never disinfected their non-infrared thermometers. This study has 3 2 6 reflected disturbing inadequate disinfection practices among physicians, whereby patient safety is of germane . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted August 15, 2020. . https://doi.org/10.1101/2020.08.14.20174433 doi: medRxiv preprint Relationship between shared patient care items and healthcare-associated infections: a systematic review Stethoscope disinfection is rarely done in Ethiopia: What are the associated factors The stethoscope and healthcare-associated infection: a snake in the grass or innocent bystander? Contamination of stethoscopes and physicians' hands after a physical examination Molecular analysis of bacterial contamination on stethoscopes in an intensive care unit Examination of staphylococcal stethoscope contamination in the emergency department (pilot) study (EXSSCITED pilot study) Stethoscope contamination with Methicillin-resistant Staphylococcus Aureus (MRSA) in an inner-city emergency department Predictors of stethoscope disinfection among pediatric health care providers Stethoscopes: a possible mode for transmission of nosocomial pathogens Bacterial contamination of stethoscopes Stethoscopes: potential vectors of Clostridium difficile The stethoscope and cross-infection revisited Stethoscopes and otoscopes--a potential vector of infection?. Family practice Stethoscope: a friend or an enemy? What′ s growing on your stethoscope? And what you can do about it International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity Methicillin-resistant Staphylococcus aureus fomite survival The role of non-critical health-care tools in the transmission of nosocomial infections Point-Prevalence of Contamination of Healthcare Workers' Stethoscopes With Vancomycin-Resistant Enterococci at Two Teaching Hospitals in Cleveland Contamination of gowns, gloves, and stethoscopes with vancomycin-resistant enterococci The stethoscope as a vector of infectious diseases in the paediatric division Stethoscopes and infection control: a study into the use of stethoscopes in a paediatric ward and their possible contamination The stethoscope in the emergency department: a vector of infection? Methicillin-resistant Staphylococcus aureus survival on hospital fomites Transfer of pathogens to and from patients, healthcare providers, and medical devices during care activity-a systematic review and meta-analysis The potential for transmission of hospital-acquired infections by non-critical medical devices: the role of thermometers and blood pressure cuffs. World health & population Bacterial profile and antimicrobial susceptibility pattern of the isolates from stethoscope, thermometer, and inanimate surfaces of Mizan-Tepi University Teaching Hospital, Southwest Ethiopia Sphygmomanometers and thermometers as potential fomites of Staphylococcus haemolyticus: biofilm formation in the presence of antibiotics. Memórias do Instituto Oswaldo Cruz Guideline for disinfection and sterilization in healthcare facilities Evaluation of stethoscopes as vectors of Clostridium difficile and methicillin-resistant Staphylococcus aureus International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity Recovery of respiratory syncytial virus from stethoscopes by conventional viral culture and polymerase chain reaction. The Pediatric infectious disease journal Persistance of coronaviruses on inanimate surfaces and their inactivation with biocidal agents prevention and control of COVID-19 in prisons and other places of detention Interim guidance Infection prevention and patient safety reference manual for service providers and managers in healthcare facilities of Ethiopia. Federal Ministry of Health Observation of stethoscope sanitation practices in an emergency department setting Factors influencing stethoscope cleanliness among clinical medical students Stethoscope cleaning during patient care A familial cluster of pneumonia associated with the 2019 novel coronavirus indicating person-to-person transmission: a study of a family cluster Emergency medicine Australasia: EMA Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1 Persistent Value of the Stethoscope in the Age of COVID-19. The American journal of medicine COVID-19 outbreak: less stethoscope, more ultrasound. The Lancet Respiratory Medicine Antimicrobial copper alloys decreased bacteria on stethoscope surfaces A new UV-LED device for automatic disinfection of stethoscope membranes Community hospital stethoscope cleaning practices and contamination rates Enterobacter cloacae outbreak in the NICU related to disinfected thermometers Enterobacter cloacae epidemic on a neonatal intensive care unit due to the use of contaminated thermometers Relationship between shared patient care items and healthcare-associated infections: a systematic review Controversies on the Stethoscope during COVID-19: A Necessary Tool or An Unnecessary Evil? Infection prevention practices and associated factors among healthcare workers in governmental healthcare facilities in Addis Ababa Decontamination of patient equipment: nurses' self-reported decontamination practice in hospitals of southeast Ethiopia 6 and independent variables. And finally, this study should be generalizable for the physicians working in the