key: cord-1043491-7zaf0jlj authors: Alhamlan, Fatimah S.; Alqahtani, Ahmed A.; Bakheet, Dana M.; Bohol, Marie F.; Althawadi, Sahar I.; Mutabagani, Maysoon S.; Almaghrabi, Reem S.; Obeid, Dalia A. title: Development and Validation of an In-house, Low-Cost SARS-CoV-2 Detection Assay date: 2021-07-15 journal: J Infect Public Health DOI: 10.1016/j.jiph.2021.07.009 sha: 7a0528cf3234258164caa1ef8ede8f5968925e6e doc_id: 1043491 cord_uid: 7zaf0jlj BACKGROUND: One major challenge for detecting the virus that causes COVID-19 is commercial SARS-CoV-2 testing kit or reagent availability. To allow every laboratory or hospital access to an in-house assay, we developed a low-cost SARS-CoV-2 detection assay protocol using in-house primers and reagents/equipment on hand in most biology or diagnostic laboratories: a SYBR Green–based RT-PCR. RNA extraction has also become a major bottleneck due to limited supplies and the required labor. Thus, we validated an alternative RNA extraction protocol. METHODS: We designed and synthesized in-house primers according to SARS-CoV-2 genome sequences retrieved from GISAID database. One hundred and ninety patient samples were collected by nasopharyngeal swab, coded, and used to develop and validate the assay protocol. RNA extraction was performed using TRI reagent-based RNA protocol to inactivate the virus; thus, testing was conducted in a conventional biosafety level 2 laboratory. RESULTS: The sensitivity and specificity of the primers were evaluated using 190 patient samples previously tested for SARS-CoV-2. The positive amplicons were sequenced to confirm the results. The assay protocol was developed, and the specificity of each RT-PCR product was confirmed using melting curve analyses. Of 190 samples, the SYBR Green–based RT-PCR assay detected SARS-CoV-2 target genes in 88 samples, with no false-positive results. These findings indicate that the sensitivity of our assay was 97.7% and specificity of 100% with those of the diagnostic laboratory that tested the same samples using a Rotor-Gene PCR cycler with an Altona Diagnostics SARS-CoV-2 kit (R(2) = 0.89). CONCLUSIONS: These approaches are reliable, repeatable, specific, sensitive, simple, and low-cost tools for the detection of SARS-CoV-2 in a conventional biosafety level 2 laboratory, offering alternative approaches when commercial kits are unavailable or not affordable. In March 2020, the World Health Organization declared a global emergency for a pandemic caused by the novel coronavirus SARS-CoV-2. This virus belongs to the Coronaviridae family, which commonly infects humans and mammals, and is an enveloped, non-segmented, positivesense RNA. This family of viruses has caused two previous epidemics: severe acute respiratory syndrome coronavirus and Middle East respiratory syndrome coronavirus infections [1, 2] Although these viruses belong to the same family, they rely on different mechanisms and have different manifestations in the human host. The newly emerged virus was first detected in Wuhan, China, and as of January 14, 2021, it had infected more than 93 million people worldwide and caused the deaths of 2 million individuals [1, 3] . To slow the spread of the virus and to contain the infection, countries across the globe are attempting to screen millions of individuals, including all health care personnel and their contacts, patients who have symptoms associated with infection by SARS-CoV-2 and their contacts, individuals who have come into contact with an infected patient, and asymptomatic individuals. People who carry the virus without showing any symptoms pose a major silent threat to public health because they are unknowingly spreading the virus. However, not all countries, hospitals, or laboratories have access to testing kits or to the reagents and supplies that are currently in high demand with which they could make their own kits. In addition, many hospitals and diagnostic laboratories are struggling with an overwhelming number of samples that have been collected but still require testing. Therefore, the aim of the present study was to develop and validate an inexpensive assay to detect SARS-CoV-2 in patient samples in almost any laboratory or hospital in a timely manner and without commercial, ready-made extraction or detection kits. This assay can use a TRI reagent-based RNA protocol for RNA extraction. The RNA extraction procedure is followed by cDNA synthesis then a SYBR Green-based RT-PCR that requires only basic science techniques and equipment. Here we provide a protocol for safely detecting SARS-CoV-2 in a conventional biosafety level 2 laboratories within a limited budget by using this easily performed assay. This study was performed in compliance with all applicable national and international ethical guidelines for conducting research on human participants, including in accordance with The Code of Ethics of the World Medical Association (Declaration of Helsinki), and was approved by the institutional review board at King Faisal Specialist Hospital and Research Centre IRB # 2200021. This board also granted a waiver for obtaining informed consent owing to the use of deidentified samples for this study. Samples were collected from each patient using a nasopharyngeal swab and then coded by the Microbiology Section of the Pathology and Laboratory Medicine Department at King Faisal Specialist Hospital and Research Centre (KFSHRC). Of these deidentified samples, those from 190 patients who were tested for SARS-CoV-2 infection were included in the present study. To accommodate the needs and available resources of various laboratories, manual and automated protocols for RNA extraction were validated To inactivate the virus, 300 μL from the patient sample was added to 700 μL of TRI reagent (Sigma-Aldrich, USA) and mixed in a biosafety cabinet in a negative pressure room. The tube was inverted 10 times and kept at room temperature for 5 min. Because this step inactivates the virus, it was safe to continue the extraction process in a biosafety level 2 laboratory. Next, 200 μL of chloroform was added, and the tube was inverted five times and then incubated for 3 min at room temperature. The sample was centrifuged at 12,000 × g for 10 min at 4 °C. The aqueous layer, which contains RNA (approximately 500 µL), was transferred to a new 1.5-mL tube, and 500 μL of isopropanol was added. The tube was inverted five times and then centrifuged at 12,000 × g for 10 min at 4 °C. The supernatant was removed, and 1 mL of 75% ethanol was added. The sample J o u r n a l P r e -p r o o f was centrifuged at 7500 × g for 5 min at 4 °C. The supernatant was removed, 1 mL of 75% ethanol was added to wash the sample, and was again centrifuged at 7500 × g for 5 min at 4 °C. The supernatant was discarded, and the pellet was air-dried. Next, 15 μL of AVE (elution) buffer was added to re-suspend the RNA. However, RNase-free water can be used instead of AVE buffer. We then added 1 μL of RNaseOut (Invitrogen, USA) to inhibit RNases and to protect the RNA from degradation. The RNA concentration and purity were determined with a NanoDrop spectrophotometer (Thermo Fisher Scientific, USA). To establish a high-throughput RNA extraction technique for mass testing, we modified the TRI reagent-based extraction for use on a Hamilton Microlab STAR Liquid Handling System. Magnet beads (ChargeSwitch ; Invitrogen) were used for purifying the total RNA from the TRI reagent lysis step. To obtain high-quality total RNA, 300 μL from the patient sample was added to 700 μL of TRI reagent (Sigma-Aldrich, USA) and mixed in biosafety cabinet in a negative pressure room using a 96-well plate. The plate was placed on a shaker for 1 min to homogenize the solution. Next, 200 μL of chloroform was added, and the plate was placed on a shaker for 1 min to again homogenize the solution and then incubated for 3 min at room temperature. The plate was centrifuged at 12,000 × g for 10 min at 4 °C. The automation process started at this step, in which the plate was placed in the Microlab STAR Liquid Handling System. Because obtaining the aqueous layer, which contains RNA (approximately 500 µL), is the most critical step in the extraction process, using an automated and robust robot improves accuracy by eliminating errors that can occur during manual processing and can extract pure RNA from a 96-well plate in less than 15 min. The synthesis of cDNA is required to prepare patient samples for subsequent PCR reactions. Total RNA extract (8 μL of approximately 50 ng/µL) was added to 1 μL of random hexamer primers and 1 μl of 10 mM dNTP Mix (Thermo Fisher Scientific). The mixture was incubated at 65 °C for 5 min and then placed on ice. Next, a master mix was prepared that consisted of 2 μL Samples were incubated at room temperature (approximately 25 °C) for 10 mins and then incubated at 50 °C for 50 min. The reaction was terminated at 85 °C for 5 min and then placed on ice. After pulse-spinning the sample, 1 μL of RNase H (to remove the RNA template from RNA-cDNA hybrid) was added, and the sample was incubated at 37 °C for 20 min. The quality and the quantity of the cDNA samples were determined using a NanoDrop spectrophotometer. The quality and the quantity of the RNA and cDNA samples were also determined using a NanoDrop spectrophotometer. The ratio of sample absorbance at wavelengths of 260 and 280 nm were obtained to assess the nucleic acid purity (approximately 2.0 for RNA and approximately 1.8 for cDNA). More than 150 complete SARS-CoV-2 genome sequences were retrieved from the GISAID database (https://www.epicov.org/epi3/cfrontend#lightbox-814829872) and were aligned using the Clustal W algorithm of the MegAlign module to identify the conserved regions using The ∆∆Ct method of relative quantification using RT-PCR with SYBR Green detection was used for this study. To detect SARS-CoV-2 target genes, comparative quantitative RT-PCR was performed using SYBR Green fluorescent dye, which binds double-stranded DNA by intercalating between the DNA bases. The 7500 Fast Real-Time PCR system and software (Applied Biosystems, California, USA) were used. The target SARS-CoV-2 genes included envelope (E), open reading frame (ORF1a), nucleocapsid (N), and RNA-dependent RNA polymerase RdRp. In addition, RNase P, Ribonuclease P, which is a type of ribonuclease that cleaves RNA that is commonly used as an internal control with human clinical specimens to confirm the presence of nucleic acid. Primers targeting the N, E, RdRp and RNase P genes were designed and synthesized in-house by the Oligonucleotide Unit of KFSHRC (Table 1) . SYBR Green RT-PCR assays using these primers generated in-house were conducted for all patient samples that were included in this study. To amplify cDNA in the patient samples, a master mix was prepared with 12.5 μL of SYBR Green master mix, 0.5 μL of forward primer (20 μM), 0.5 μL of reverse primers (20 μM), 2 μL of cDNA, and 4.5 μL of water (for a total of 20 μL). The amplification conditions were 50 °C for 20 secs and 95 °C for 10 mins followed by 45 cycles of 95 °C for 3 s with 55 °C for 30 s. At the end of each reaction, the cycle threshold (Ct) was acquired at the level that reflected the best kinetic PCR parameters. SYBR Green is released when a PCR product is denatured, which results in a rapid increase in absorbance intensity (fluorescence signal) followed by a decrease in the signal. When an amplified PCR product is specific, a melting curve generated using that product should provide a single peak that corresponds to that PCR product. Thus, to check the specificity of each PCR product, we conducted a melting curve analysis at the end of each PCR assay. Each product sample was analyzed once. For the melting curve, the fluorescence signal of each PCR product was monitored continuously as the temperature was increased to 95 °C for 15 s, decreased to 60 °C for 1 min and then increased again to 95 °C for 30 s and 60 °C for 15 s. During RNA extraction using TRI reagent, we obtained an average of 20 ng/μl from each sample. To evaluate the RNA extraction method, RNA samples extracted with TRI reagent at the research laboratory were sent to a diagnostic laboratory for testing. The results showed that the Ct values for the RNA extracted using these methods were similar and also indicated the compatibility of the RNA extraction procedure using TRI reagent with the Rotor-Gene system using the Altona Diagnostics kit. For a valid diagnostic test, the sample was considered positive for SARS-CoV-2 when the cycle threshold growth curves for both target genes crossed the threshold line within 40 cycles (<40.00 Ct) regardless of whether the RNase P growth curve also crossed the threshold within 40 cycles. A sample was considered negative for SARS-CoV-2 when the cycle threshold growth curves for both targets did not cross the threshold line within 40 cycles (>40.00 Ct) but the RNase P growth curve did cross the threshold line within 40 cycles. Figure 1 shows a representative RT-PCR J o u r n a l P r e -p r o o f amplification plot. Figure 1 depicted a representative amplification plot the showed two target genes (E, RdRp, an internal positive control (IPC, RNase P) and a no-template control (NTC)). Ct value for the Altona diagnostic test was (24.5) while the Ct value for SYBR Green assay was (27.2) (R 2 =0.89, P <0.001). Parallel tests to detect SARS-CoV-2 were conducted by a diagnostic laboratory accredited by the 38. In addition, the melting curve analyses showed a single peak for each positive sample. The analyzed sequences matched the WH-human1 SARS-CoV-2 sequence (MN908947). To determine the limit of detection, 10-fold serial dilutions using a plasmid with a known copy number (104/μL) were tested. Real time PCR was used to assess the sensitivity of the assay. The limit of detection is the lowest concentration of the diluted sample that returns a positive result. Our results showed that the limit of detection for our assays was 10 copies/µL (results are not shown). Although commercial viral RNA extraction kits are available and are widely used in most laboratories, the aim of the present study was to use basic biology techniques that can be adopted J o u r n a l P r e -p r o o f by hospitals or laboratories worldwide, especially given that the availability of commercial kits or specialized reagents may be at risk. Thus, we developed and validated a low-cost, easily performed assay for detecting SARS-CoV-2 using a SYBR Green RT-PCR assay. The test can be conducted using equipment and reagents already found in most pathology or diagnostic laboratories. Testing with RT-PCR has been considered the gold standard for diagnosing COVID-19, with infected individuals identified by the successful amplification of the viral genome obtained using nasopharyngeal swabs. However, recent studies have stated some concerns regarding the specificity of the RT-PCR tests for patients with COVID-19 [4] . Indeed, inaccurate results, especially a false-negative, have dire implications for subsequent community transmission of the virus [5] . There are many factors causing the false negative RT-PCR results, a big one is the genetic diversity of the virus, low viral load, or sampling error and handling [6] . The first problem can be minimized by an assay with multiple targets and sequence monitoring. While the other one could be prevented by improving sampling guidelines and procedure. Therefore, the inclusion of two SARS-CoV-2 genes and internal control for accurate detection has been advised [7] . In the present study, we designed sets of primers that target the E, ORF1ab, and RdRp genes of the virus and RNaseP of the human in addition to the CDC primers (N1, N3 and RNaseP). For SARS-CoV-2 detection assay, at least two genes and one control are recommended. We have designed and validated all primer sets in this study to make it available to other laboratories worldwide to choose primer sets for genes of interest. Of 190 samples, the SYBR Green-based RT-PCR assay detected SARS-CoV-2 in 88 samples, with no false-positive results. Our results showed 97% sensitivity and 100% specificity in comparison to those of the diagnostic laboratory (Altona Diagnostics SARS-CoV-2 kit). It is true that the P value showed a statistically significant difference between these two assays (T-Paired=11.1, P-value < 0.0001) however the missed two samples had late Ct value which is considered to be "non-infectious" specimen according to recent studies [8, 9] . Further studies have also recommended adding the Ct value to the reporting system as it is helpful for clinical decisions. Reporting the SARS-CoV-2 results as positive and negative is insufficient and needs to be improvised [10] . J o u r n a l P r e -p r o o f SYBR Green RT-PCR is widely used because of the ease in assay design and its relatively low setup and running costs. Unlike TaqMan fluorescent probes, SYBR Green dye intercalates into double-stranded DNA to monitor the amplification of the target gene specifically initiated by gene-specific primers [11] . However, one drawback of the SYBR Green assay is that the dye is nonspecific, and this lack of specificity can generate false-positive signals if nonspecific products or primer-dimers are present in the sample. However, including a melting curve analysis at the end of each PCR assay to determine the specificity and efficiency of each RT-PCR reaction will ensure the accuracy of the results when multiple peaks or primer-dimers are not observed. Another potential drawback of the SYBR Green assay is that the length of the amplicon may affect the intensity of the amplification; thus, the present study designed primers with short amplicon. The time of testing can be improved by removing the nucleic acid assessment step by Nanodrop as we found it to be time consuming and not efficient with SYBR Green assay, for quality check we can use the internal control (RNAseP) gene. Ebola virus and other highly pathogenic viral agents, indicating that using TRI reagent offers excellent performance and a safer environment for handling pathogens in a biosafety level 2 laboratory [12] . This is because TRI reagent has been shown to denature and destabilize the viral envelope and eliminate cellular nucleases while maintaining the structure of RNA for subsequent analyses. The total cost for the SYBR Green assay was estimated to be $21. It is true that the time is longer to run in-house assay (3 hours) in comparison to commercial RT-PCR kits however the cost for any commercial kit is considerably higher. We believe that the SYBR Green assay using RT-PCR is the more favorable choice owing to its potential power in the field of virology, its availability, and real-time data analysis [13] . In conclusion, we developed and validated a lowcost assay for detecting SARS-CoV-2 that can be used by laboratories that cannot afford or cannot obtain commercial testing kits especially during this time where when SARS-CoV-2 is globally pervasive and deadly and commercial kits are limited. This in-house assay offers viable alternative testing approaches. In addition, these protocols provide virus testing platforms for future threats because the only change that would be required to follow the same protocols to test for a different virus would be the pathogen sequence needed to design specific primers. The funders had no role in the study design; in the collection, analysis and interpretation of data; in the writing of the article; and in the decision to submit the article for publication. Coronavirus as a possible cause of severe acute respiratory syndrome Commentary: Middle East respiratory syndrome coronavirus (MERS-CoV): announcement of the Coronavirus Study Group Coronavirus disease 2019 (COVID-19) Situation Report Chest CT for Typical Coronavirus Disease 2019 (COVID-19) Pneumonia: Relationship to Negative RT-PCR Testing A Patient with COVID-19 Presenting a False-Negative Reverse Transcriptase Polymerase Chain Reaction Result Reducing False Negative PCR Test for COVID-19 Dynamic change process of target genes by RT-PCR testing of SARS-Cov-2 during the course of a Coronavirus Disease 2019 patient No correlation between Ct values and severity of disease or mortality in patients with COVID 19 disease Predicting infectious SARS-CoV-2 from diagnostic samples A Narrative Systematic Review of the Clinical Utility of Cycle Threshold Values in the Context of COVID-19 Quantitative detection of reverse transcriptase-PCR products by means of a novel and sensitive DNA stain n General Procedures For Inactivation Of Potentially Infectious Samples With Ebola Virus And Other Highly Pathogenic Viral Agents Detection of Herpes simplex virus DNA by real-time PCR Plot showing the Ct value of two target genes (E, RdRp, an internal positive control (IPC, RNase P) and a no-template control (NTC)). The lower the Ct value, the greater the sensitivity. ∆Rn indicates Rn (the reporter signal normalized to the fluorescence signal of Applied Biosystems ROX Dye) minus the baseline We are grateful to the Department of Pathology and Laboratory Medicine chaired by Dr. Fouad Aldayel and to staff member Ms. Sarah Altamimi, who provided the deidentified patient samples. We thank Mr. Paul N. Muiya for synthesizing the PCR primers in less than 16 hours.We also thank Dr. J o u r n a l P r e -p r o o f