key: cord-1041712-jh7s1hyd authors: Kaestner, Lena; Abo-Madyan, Yasser; Huber, Lena; Spaniol, Manon; Siebenlist, Kerstin; Sacks, Marie-Kristin; Ehmann, Michael; Stieler, Florian; Clausen, Sven; Lohr, Frank; Fleckenstein, Jens; Boda-Heggemann, Judit title: Motion Management in a Patient With Tracheostomy During Lung Stereotactic Body Radiation Therapy: Breath Hold Is Worth a Try date: 2022-01-15 journal: Adv Radiat Oncol DOI: 10.1016/j.adro.2022.100895 sha: 2202ae376fdb8760d4c6c307c11059a045a6b734 doc_id: 1041712 cord_uid: jh7s1hyd nan Stereotactic body radiation therapy (SBRT) is an appropriate noninvasive treatment option with excellent tumor control rates and overall survival for patients with stage IA non-small cell lung cancer or oligometastases who are medically inoperable or have a high surgical risk. [1] [2] [3] [4] [5] [6] To ensure safe dose application during SBRT, a time-resolved motion management strategy is required. In case of breathing-induced uncertainties, possible motion management options include breath hold and free-breathing techniques in combination with either gated or continuous beam-delivery with an internal target volume (ITV) or dynamic tumor tracking. 7, 8 Deep inspiration breath hold (DIBH) during lung-SBRT leads to expanded healthy lung tissue and tumor immobilization, thus reducing planning target volume (PTV) margins and lung dose compared with ITV-based radiation therapy in free-breathing. [9] [10] [11] It can be performed voluntarily or computer-controlled using spirometrical or surface-based systems. 12 However, a reliable breath hold cannot be performed by all patients, especially when the respiratory capacity is reduced due to comorbidities or previous surgery. In this article, we present the case of a patient treated with lung-SBRT in DIBH for the first time despite previous tracheostomy and reduced respiratory capacity. A 60-year-old male patient with simultaneous pulmonary adenocarcinoma (cT1b cN0 M0 [American Joint Committee on Cancer IA2] non-small cell lung cancer) and oropharyngeal cancer (cT3 cN2b M0) was presented for initiation of lung-SBRT. Accompanying illnesses included arterial hypertension, bronchial asthma, and advanced chronic obstructive pulmonary disease. The interdisciplinary oncological conference recommended to treat the head and neck cancer first, followed by resection of both pulmonary lesions as a 2-step Sources of support: For the publication fee we acknowledge financial support by Deutsche Forschungsgemeinschaft within the funding programme "Open Access Publikationskosten" as well as by Heidelberg University. Disclosures: none. Research data are stored in an institutional repository and may be shared upon reasonable request to the corresponding author. *Corresponding author: Lena Kaestner, MD; E-mail: lena. kaestner@umm.de process. In accordance with that, the oropharyngeal tumor was treated with surgical resection (pT3 pN0 [0/ 44] V0 L0 Pn1 G2 R0, marginal carcinoma in situ R1), tracheostomy, and adjuvant chemoradiotherapy (70 Gy and 2 cycles of cisplatin 100 mg/m 2 q3w). A renewed staging showed no new thoracoabdominal metastases or signs of pulmonary progression. Body plethysmography resulted in an forced expiratory volume in one second of 34% with limited validity due to the patient's tracheostomy. In consideration of the already limited pulmonary function, both lungs being affected, and the ongoing COVID-19 pandemic, the patient was introduced for pulmonary SBRT. At radio-oncological consultation, the patient presented with a body mass index of 21.8 kg/m 2 and a Karnofsky performance status of 70%. Due to the patient's tracheostomy and reduced forced expiratory volume in one second, a 4-dimensional (4D) planning computed tomography (CT) (Brilliance Big Bore; Philips, Eindhoven, Netherlands) was acquired to account for breathing-induced tumor motion. Due to localization in the lower lobes, the resulting ITVs were relatively large compared with the actual size of each lesion (right/left ITV 11.1/16.5 cm 3 vs gross target volume 2.2/3.5 cm 3 ; Table 1 ). After ensuring that the patient was comfortable with the technique of repeat DIBH despite tracheostomy and that the size of the resulting PTVs and with that the low-dose wash in the volumetric-modulated arc therapy arcs on both lungs could be reduced, we opted for replanning in DIBH. Doses to organs at risk (OARs) were lower in the 4D-CT setup, so that, fulfilling the principle of As Low As Reasonably Achievable, we decided to choose the DIBH plan. To be able to perform DIBH, the patient used his nonfenestrated inner cannula (Ultrasoft-Suction-Voice; Andreas Fahl Medizintechnik-Vertrieb GmbH, Germany) in combination with the already inflated tracheostoma cuff and practiced holding his breath for 20 seconds (Fig 1) . Blocking of the tracheostoma cuff was not changed during radiation therapy. Afterward, 10 MV flattening filter free volumetric-modulated arc therapy plans were created with Monaco 5.51 (Elekta AB, Stockholm, Sweden) on both 4D-planning CT and DIBH-planning CT. Dose prescription for the right lesion was 12 £ 5 Gy daily (owing to localization in the proximity of thoracic wall; DIBH/4D-CT: D0.5 cm 3 [5 Fx <39 Gy] 54.7/60.2 Gy, D30 cm 3 [5 Fx <32 Gy] 21.7/31.6 Gy 13 ) and for the left lesion 5 £ 12 Gy every second day. 14 Planning constraints were mainly derived from the UK SABR Consortium Report. 13, [15] [16] [17] SBRT was performed with the DIBH plans as all dosimetric parameters were more favorable compared with the 4D-CT plans. Summed (left and right lesion) DIBH and 4D-CT plans were additionally evaluated offline (Velocity; Varian, Palo Alto, CA). For both DIBH and 4D-CT plans the following dosimetric parameters were analyzed: PTV volumes of the lesion in the right and left lower lobe were 18.1 versus 33.2 cm 3 and 23.3 versus 43.8 cm 3 for the DIBH and 4D-CT plans, respectively, with similar dose distribution ( Table 1, Fig 2) . Mean lung dose was smaller in the DIBH plans (6.5 Gy) than in the 4D-CT plans (9.3 Gy) with V13.5 and V20 of 17.5% and 10.1% in the DIBH and 24.4% and 15.9% in the 4D-CT plans, respectively. Dose to the heart was comparable; however, it was also more advantageous in the DIBH plan (D mean 8.5/10.8 Gy and D0.5 cm 3 28.6/34.2 Gy in DIBH/4D-CT plans). SBRT was performed on a linear accelerator (Versa HD, Elekta AB) in repeated DIBH. The median table time/fraction with 2 SBRT series was 15 minutes. 18 In advance of each fraction daily image guidance was performed with repeated DIBH cone beam computed tomography (DIBH-CBCT), 19 as shown in Figure 3 . DIBH-based SBRT could be completed as planned and no acute side effects occurred. Both lesions are locally controlled (to the time point of writing the article; Fig E1) . Repeated DIBH is a feasible alternative motion management method for lung-SBRT in tracheostomy patients compared with continuous beam delivery in free breathing. To our knowledge, the case of breath hold gated SBRT in a patient with a protective tracheostomy has never been reported. The use of DIBH instead of 4D-CT led to reduced target volumes and reduced dose to OARs (mean lung dose 6.5 vs 9.3 Gy, mean heart dose 8.5 vs 10.8 Gy) with comparable PTV coverage. The amplitude of tumor motion depends on localization (greater amplitude in the lower lobe) and whether the tumor is attached to rigid structures. 20 Therefore, the effect of reduced dose to OAR with DIBH may be either smaller or even larger for different target localizations. DIBH-gated SBRT should especially be considered in tumors with estimated great breathinginduced motion amplitude. Treatment outcomes for patients with oligometastatic, oligoprogressive, or polymetastatic disease have improved in the last years due to advanced local therapy options and modern systemic targeted/immunotherapies. With that, however, SBRT is more often being combined with drugs, which may result in excess or unexpected toxicity such as fulminant pneumonitis or myocarditis under immunotherapy. 21, 22 In the last few years, local ablative SBRT has not only been indicated in oligometastatic or in oligoprogressive situations but also for up to 10 or even more metastases. 23, 24 Additionally, with improving overall survival repeated SBRT series occur more often. 25 These factors lead to difficulties in obtaining OAR dose constraints. Technical improvements help achieve optimal dose in the target volumes with minimal dose to OARs, enabling sophisticated and ambitious RT plans. Therefore, not only the violation of constraints should be an indication for advanced techniques: In all SBRT cases the most favorable technique should be chosen to minimize dose to OARs. A spirometrical breath hold system could not be applied, 26 as it is only designed for oral and nasal air flow. Alternatively, breath hold can be performed and monitored with optical surface scanning systems, pressure belt, or other nonspirometrical alternatives in tracheostomy patients. 27, 28 The detected amplitude of residual motion during surface-guided DIBH had a maximum range between 1.3 and 10.4 mm per DIBH (standard deviation, 0.3-1.3 mm). This is in line with already published data on residual motion during breath hold in patients receiving lung-SBRT: Koshani et al 29 measured short-and long-term reproducibility of lung tumor positions during Active Breathing Coordinator-controlled breath hold with a standard deviation of 1.5 and 3.8 mm in anteriorposterior direction. In another study, the intrafractional interquartile range during DIBH-gated surface-guided lung-SBRT was 2.5 mm. 30 DIBH for this patient was enabled by using a nonfenestrated cannula in combination with the blocked protective tracheostoma. Consequently, the breathing air mainly passed the tracheostoma with no opportunity to close the vocal fold to build up pressure for breath hold. In general, breath holding in patients with tracheostomy can either be performed by sealing the tracheostoma (finger or cap) or imitated by continuously inhaling. In patients after laryngectomy DIBH should not be tried because such a patient is only able to breathe through the Fig. 1 Sagittal computed tomography scan and schematic image of the patient's tracheostoma with a nonfenestrated inner cannula. The cuff was always blocked during radiation therapy and therefore the airflow was directed via the tracheostomy tube (yellow arrows). tracheostoma and for performing breath hold it would have to be sealed. A very compliant patient like our patient might be able to inhale continuously to reduce motion. In conclusion, especially for target lesions with a large motion amplitude, DIBH should be considered as an alternative to free breathing/ITV-based target definition when planning SBRT for moving targets (lung, liver, kidney, adrenal glands) in compliant patients with a protective tracheostomy. Beam application was only performed if the motion amplitude was in the previously defined gating window. In spite of his tracheostomy, our patient was able to perform a stable, repeated, surface-guided deep inspiration breath hold. Fig. 3 Deep inspiration breath hold−only cone beam computed tomography (CBCT) scans of both targets (pink = planning computed tomography; green = CBCT). CBCT with repeated deep inspiration breath hold has almost a diagnostic quality in tissues with high contrast and makes daily matching more precise than 4-dimensional computed tomography. Advances in Radiation Oncology: XX 2022 DIBH lung-SBRT in a patient with tracheostomy National Comprehensive Cancer Network. Non-small cell lung cancer 7-year follow-up after stereotactic ablative radiotherapy for patients with stage I non-small cell lung cancer: Results of a phase 2 clinical trial Stereotactic ablative radiotherapy for the comprehensive treatment of oligometastatic cancers: Long-term results of the SABR-COMET phase II randomized trial Long-term results of stereotactic body radiation therapy in medically inoperable stage I non−small cell lung cancer Stereotactic ablative radiotherapy versus standard radiotherapy in stage 1 non-small-cell lung cancer (TROG 09.02 CHISEL): A phase 3, open-label, randomised controlled trial Stereotactic ablative radiotherapy in operable stage I NSCLC patients: Long-term results of the expanded STARS clinical trial Definition and quality requirements for stereotactic radiotherapy: Consensus statement from the DEGRO/DGMP Working Group Stereotactic Radiotherapy and Radiosurgery The impact of technology on the changing practice of lung SBRT Impact of a breathing-control system on target margins and normal-tissue sparing in the treatment of lung cancer: Experience at the radiotherapy unit of Florence University Clinical outcome of hypofractionated breath-hold image-guided SABR of primary lung tumors and lung metastases Local control rates with five-fraction stereotactic body radiotherapy for oligometastatic cancer to the lung Deep inspiration breath hold-based radiation therapy: A clinical review Stereotactic ablative body radiation therapy (SABR): A resource Characterisation and classification of oligometastatic disease: A European Society for Radiotherapy and Oncology and European Organisation for Research and Treatment of Cancer consensus recommendation Population-based phase II trial of stereotactic ablative radiotherapy (SABR) for up to 5 oligometastases: SABR-5 Stereotactic ablative radiotherapy for the comprehensive treatment of 4-10 oligometastatic tumors (SABR-COMET-10): Study protocol for a randomized phase III trial Organ at risk dose constraints in SABR: A systematic review of active clinical trials Flattening-filter-free intensity modulated breath-hold image-guided SABR (stereotactic ablative radiotherapy) can be applied in a 15-min treatment slot Multiple breathhold CBCT for online image guided radiotherapy of lung tumors: Simulation with a dynamic phantom and first patient data Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy Pulmonary toxicities associated with the use of immune checkpoint inhibitors: An update from the Immuno-Oncology Subgroup of the Neutropenia, Infection & Myelosuppression Study Group of the Multinational Association for Supportive Care in Cancer Immune checkpoint inhibitors and cardiac toxicity: An emerging issue The spectrum of metastasis: An opportunity for cure? Can polymetastatic disease be ARRESTed using SABR? A dosimetric feasibility study to inform development of a phase 1 trial Stereotactic body radiotherapy (SBRT) for multiple pulmonary oligometastases: Analysis of number and timing of repeat SBRT as impact factors on treatment safety and efficacy Lung tumor reproducibility with active breath control (ABC) in image-guided radiotherapy based on cone-beam computed tomography with two registration methods IGRT and motion management during lung SBRT delivery Motion compensation in radiotherapy Short-term and long-term reproducibility of lung tumor position using active breathing control (ABC) Feasibility of optical surfaceguidance for position verification and monitoring of stereotactic body radiotherapy in deep-inspiration breath-hold We thank our patient for allowing us to analyze his data and to publish them as a case report. Supplementary material associated with this article can be found in the online version at doi:10.1016/j.adro.2022. 100895.