key: cord-1041416-lspjoppe authors: nan title: The role of lung ultrasound in COVID-19 disease date: 2021-06-19 journal: Insights Imaging DOI: 10.1186/s13244-021-01013-6 sha: 7d9b8b84baf3a1ca1db4d28b8002e4ce8fd6bd5d doc_id: 1041416 cord_uid: lspjoppe This statement summarises basic settings in lung ultrasonography and best practice recommendations for lung ultrasonography in COVID-19, representing the agreed consensus of experts from the Ultrasound Subcommittee of the European Society of Radiology (ESR). Standard lung settings and artefacts in lung ultrasonography are explained for education and training, equipment settings, documentation and self-protection. According to the Center for Systems Science and Engineering (CSSE) at Johns Hopkins University (JHU), Coronavirus COVID-19 disease prevalence has increased globally day-to-day since early 2020, passing a total of more than 111 million infections worldwide in mid-February 2021, and more than 2.45 million deaths worldwide by this date. At the time of writing, the number of proven cases continues to rise, particularly in the USA, Russia, South America and Europe [1]. On 12 March 2020, the World Health Organization labelled the outbreak as a pandemic infection with a previously unknown type of coronavirus named SARS-CoV-2 [2] . The infection, formally named COVID-19 (Coronavirus disease 2019) by the WHO on February 11th. 2020, is usually fairly mild, but causes severe pneumonia in a minority of infected patients, potentially developing into respiratory failure and death due to bilateral pulmonary involvement [3] . The extensive and rapid spread of the infection, with the need of advanced health care support, has made this pandemic a serious health emergency. Spreading mainly through the droplet route, the virus predominantly causes mild symptoms, the most common being temperature (80%), dry cough (56%), fatigue (22%) and muscle pain (7%); less common signs include a painful throat, a runny nose, diarrhoea, haemoptysis and chills [4] . A life-threatening difficulty of SARS-CoV-2 contamination is an acute respiratory distress syndrome (ARDS) [5] , which happens more frequently in older adults, persons with immune disorders and co-morbidities. Severe forms of the infection (respiratory failure, ARDS, sepsis and septic shock) require management in the intensive care unit and, sometimes, mechanical ventilatory support [4] . Insights into Imaging Due to the continual development of their clinical condition, critically ill patients need thoracic imaging frequently [6] . Thoracic ultrasonography can make a substantial contribution, as it allows direct bedside examination of the lung and pleural space [7] . Patients with COVID-19 show typical CT patterns, such as diffuse bilateral interstitial pneumonia, with irregular, patchy lesions distributed mainly in the periphery of the lung [8] [9] [10] [11] [12] [13] [14] [15] . Multislice-CT remains the gold standard imaging method for thoracic evaluation [16] . As pulmonary irregularities may develop before clinical appearances and confirmation of viral infection by polymerase chain reaction (PCR), some have suggested primary lung CT for screening suspected patients [17] , regardless of limited sensitivity. However, lung MS-CT examinations expose patients to ionising radiation, and should be reserved for specific purposes, for instance circumstances establishing the baseline status of severely ill patients, confirmation of pulmonary embolism and evaluation of mediastinal pathologies [18] [19] [20] . The standard of care in the ICU is still bedside chest X-ray (CXR). Nevertheless, CXR has significant methodological limitations and is often of low accuracy in identifying disease [21] . Additionally, it is important to consider radiation protection issues [22] . Chest CT has limitations in unstable ICU patients with hypoxemia and hemodynamic failure. Additionally, there are risks of causing harm when transporting the patient, and the high contagiousness of SARS-CoV-2 could induce spread of the infection in the hospital [16, 23] . Lung ultrasonography in experienced hands can give results comparable to chest CT and superior to standard chest radiography for evaluation of pneumonia and/ or adult respiratory distress syndrome (ARDS), with the additional benefit of ease of use, repeatability, absence of radiation exposure, and low cost [17, 24] . The appropriate practice of ultrasonography could decrease CXR and CT use in patients in the ICU [7] . Thoracic and lung ultrasonography have increased in importance over the past decade [25] [26] [27] [28] [29] [30] , particularly in the setting of point of care ultrasonography (POCUS) [31] . A lung ultrasonography examination was first executed more than half century ago [32, 33] . Excepting echocardiography and obstetrical use, ultrasonography has predominantly been a tool used by radiologists and the lung wasn´t considered suitable for this imaging technology historically [34] [35] [36] . Nonetheless, since 1991, intensivists have been using ultrasonography in a variety of settings, including in vascular access, to detect free fluid in body cavities and, to a lesser extent, in lung assessment [37] . Severe dyspnoea is a common presenting initial sign in the emergency room and the ICU. The variety of thinkable differential diagnoses is extensive; after history-taking, physical examination and determination of the vital parameters, prompt bedside emergency ultrasonography can be helpful. Focused pulmonary ultrasonography is a significant component of emergency ultrasonography beside dedicated ultrasonography of the abdomen and heart. While recommendations exist for elective chest ultrasonography [38, 39] and point of care pulmonary ultrasonography [25] , emergency pulmonary ultrasonography has not yet been extensively adopted in everyday practice [40] . In experienced hands, pulmonary ultrasonography shows brilliant diagnostic accurateness in identifying pleural effusion, pneumothorax, pulmonary venous congestion and consolidation, compared to clinical examination and CXR [21, 41, 42] . In the diagnosis of lung pathologies, ultrasonography artefacts arising from the chest wall and pleural surface can provide valuable information and may correlate with the existing lung pathophysiology. There are two major ultrasonographic artefact patterns that a clinician may detect: "A-lines" and "B-lines" in rare cases even "C-lines" are visible [43] . A-lines are reverberation artefacts triggered by oscillating tissue with an air interface, causing the ultrasonography waves to be reflected strongly and to reverberate [22, 44] . Among the probe and lung surface, the ultrasonography waves bounce back and forth. A-lines are parallel horizontal repetition lines of the pleural surface, appearing deeper on the display screen ( Fig. 1 ). Due to the fact that this is a classic reverberation artefact, the distance from the skin to the pleural surface equals the distance from the pleural line to the first A-line, the first A-line to the second A-line, and so forth. The A-profile is shaped by intact ("dry") lung parenchyma containing air when it is combined with normal lung sliding. If sliding is absent, it is intensely suggestive of a pneumothorax [45] . In 1982, Ziskin et al. first described the "comet-tail" ultrasonographic sign, seen when an intrahepatic shotgun pellet was detected to generate an artefact like to what is seen in celestial comets [45] . On lung ultrasonography, usual comet-tail artifacts originate at the pleura but fade before reaching the edge of the screen. According to the international consensus conference, B-lines are spreading to the bottom of the screen without fading, not only pronounced [25, 48] . B-lines seen as vertical hyperechoic artefacts originating from the pleura or areas of consolidation [46] . B-lines indicate an accumulation of fluid in the pulmonary interstitial space or alveoli. The presence of several B-lines is related with pulmonary oedema, of cardiogenic, noncardiogenic (acute respiratory distress syndrome) or mixed origin. Additionally multiple B-lines are reported in pulmonary fibrosis, and pneumonia [25, 48] . B-lines arise when sound waves pass through the superficial soft tissues and cross the pleural line, encountering a mixture of air and water [23] . The anatomic and physical basis of B-lines is not known with certainty at this time [25] . One or two B-lines may be normal, but when they increase in number or spread in one zone, they are a sign of severe pulmonary interstitial oedema [39, 47] (Fig. 2) . C-lines are small anterior lung consolidations suggest pneumonia; they are 18 times more often than pulmonary embolism [34] (Fig. 3 ). For preoperative and postoperative transthoracic ultrasonography, most conventional US systems are suitable, using the "real-time B-mode" technique. There is a broad selection of different ultrasonography transducers which may be used for lung ultrasonography (LUS) [39, 48] . Each transducer has specific advantages and limits; transducer choice depends on numerous factors, principally patient anatomy, size and age and the depth and nature of the visualised structures [23] . Published studies on lung ultrasonography have used a variety of transducers, including high-frequency linear, low-frequency curvilinear and low-frequency sector transducers. In most of the cases, the use of convex and linear transducer will be sufficient [47] . Low-frequency probes will offer greater depth penetration, but will sacrifice some image quality. High-frequency probes will offer better resolution to observe lesions in the pleural line, but will sacrifice depth penetration [47, 48] . The performance and interpretation of lung ultrasonography is not probe-specific [48] . The most suitable transducer for bedside lung ultrasonography (BLUE) will be low-frequency convex transducers, because they can visualise the deep postero-lateral structures and can reveal consolidation and pleural effusion [23, 45] . In patient with COVID-19 disease, the whole lungs have to be scan because the process especially at the beginning can be visible in multiple places in order not to miss interstitial changes. High-frequency linear transducers, with more-shallow penetration, may be superior for identifying pneumothorax and examining the superficial anterior structures. They are suitable for children and thin adults [39] . Specialised phased-array and microconvex transducers can be used to detect a broad variety of abnormalities, such as consolidation and pleural effusion [47] . In order to evaluate vessels and the vascularisation of pathological findings, basic ultrasonography units should be equipped with pulsed and colour Doppler and M-mode [49] . The diagnostic value of B-mode ultrasonography can be enhanced by using the dynamic M-mode. In the M-mode setting, a solitary vertical line of the ultrasonography image is selected. The detected ultrasonography signals of this line are displayed over time in a separate diagram. By using this M-mode setting, tissue movements will be represented as curves. Structures which are not moving appear as a horizontal line. By using the M-mode technique, the system displays a representation of tissue motion over time during the lung examination [44] . In order to improve B-mode quality, most ultrasonography manufacturers use Compound Imaging and Harmonic Imaging. By disabling these modes, comet-tail artefacts or B-lines will be displayed more clearly [39, 44] . Standard settings such as focal zone, image depth and overall gain should be adjusted to improve visualisation of the pleural line [50] . Due to the extended exposure time of ultrasonography operators scanning COVID-19 patients, the risk of coronavirus transmission will be increased. Therefore adequate personal protective equipment should be worn while examination COVID-19 positive patients or patients with a high risk of being COVID-19 positive. According to Piscaglia et al., personal protective equipment should include FFP2 (N95) or FFP3 faces masks, gloves, disposable caps, shoe covers, protective glasses, goggles or face barriers in order to protect operators from potentially infectious patients, and also to protect patients from contracting COVID-19 from asymptomatic healthcare personal [39, 47, 51, 52] . Most ultrasonography systems are not designed for cleaning with liquid disinfectants. Extended disinfection with liquid disinfectant solutions will almost invariably damage the controls, knobs and keypad. To resolve this problem, the US machine should be covered entirely with transparent, thin, disposable nylon/ plastic bags. This may interfere with cooling of the ultrasonography system, and potential overheating should be monitored. An additional option is to only cover the screen and the main keyboard/controls [53, 54] . Unfortunately, if no protective cover is used, it is difficult to be certain that every part of the scanner has been disinfected after use. Some recently developed ultrasonography scanners have adapted to these considerations, increasing machine resistance to disinfectants and making it easier to clean and disinfect the main body of the equipment [51] . Under standard ultrasonography examination circumstances a cleaning tissue to wipe the probes might be adequate [55, 56] . Nevertheless, due to the increase in hazardous transmittable infections such as SARS-CoV-2 or methicillin-resistant staphylococcus, most manufacturers and scientific societies tend to suggest procedures such as immersion of the transducer in a disinfectant solution for 1-5 min, or, alternatively, in a stronger disinfectant solution for at least 30 s [51] . Unfortunately, these procedures are complex and time-consuming, and therefore acceptance of these suggestions may be limited [15, 53] . Additionally, the immersion of probes in potent disinfectant could damage some probes after as few as 50-100 disinfecting cycles, making such procedures impracticable. In order to avoid most of these problems, disinfecting procedures should be of minimal complexity, while preserving patient and probe safety [51] . The use of a thin and disposable nylon/plastic cover for the transducer can minimise these problems [23, 47] . Advanced cleaning solutions must be discussed with local infection control and the vendors supplying the machine in order to avoid any damage to the system and transducer [53, 54] . Lung ultrasonography is used in emergency and ICU patients in recumbent (ventral thorax) and-depending on the clinical situation-in a sitting position (dorsal thorax). In order to cover the complete lung, the examination should be performed in a systematic manner that investigates the entire anterolateral and posterior lung surfaces bilaterally; if necessary, selective regional lung ultrasonography can be performed with a patientfocused abbreviated approach [39] . According to Lu et al., each hemithorax should be divided into six regions [57] : anterior superior, anterior inferior, lateral superior, lateral inferior, posterior superior and posterior inferior. These areas should be marked as R1-R6 and L1-L6, respectively, a standard pictorial proforma could be used to fill so that response in followup US studies can be accurately documented [23, 39, 47] Usually, transthoracic scanning windows, using the intercostal spaces, will be used for the examination of the lung and pleura [40] . In most standard examinations, a convex array transducer will be used and should be placed at right angles to the ribs so that two adjacent ribs are captured. This setting allows the lung to slide, i.e. the movement of the visceral pleura can be reliably identified and distinguished from the anterior rib artefact. In order to cover the complete lung, this technique should be used for each intercostal space of the upper and lower parts of the anterior, lateral and posterior regions as well of the left and right chest wall [58] . If subsequently focusing on suspected subpleural lesions, a linear array transducer may improve the resolution of superficial structures [39] . Ultrasonography can be useful in addition to CT and CXR, or on its own, for the primary diagnosis and followup of COVID-19 disease [22] . COVID-19 pneumonia is more likely than non-COVID-19 pneumonia to have a peripheral distribution [59] . The morphology and variations of subpleural lesions, changes of air and water content in consolidated peripulmonary tissues and air bronchograms, can be detected, using the low-frequency capability of curved transducers [23] (Fig. 4) . The findings and treatment of central lung diseases is currently limited in lung ultrasonography, due to the attenuation of sound waves by normal lung and bone tissues. The diagnosis of lung ultrasonography abnormalities relies on the artefacts created by peri-pulmonary lesions [60, 61] . An abnormal ratio of air and water content in alveoli and interstitial tissues created these artefacts. In lung ultrasonography of COVID-19 disease, we typically find thickening of the pleural line with pleural line abnormality. Additionally, the pleural line may appear discontinuous (interrupted) [17, 62] (Fig. 5) . The presence of B-lines artefacts (> 3 B-lines per intercostal space) will vary among focal, multifocal and confluent patterns of involvement [23] . The extent of consolidation may change in different patterns, from multifocal, small, subpleural consolidations up to nontranslobar and translobar involvement, with occasional air bronchograms [23, 63] . In COVID-19 lung disease, pleural effusions are uncommon; patients are generally more critically ill if pleural effusions are seen (Fig. 6 ). An indirect sign of recovery is the presence of ultrasonography A-lines through the recovery phase [23, 39, 47, 64] (Fig. 7) . Lung ultrasonography has substantial use in management of COVID-19 pneumonia in the ICU, due to its non-invasive assessment and dynamic observation of lung lesions [39, 64] . Lung ultrasonography can show typical pattern for interstitial pneumonia; in COVID-19, it is mainly involving the peripheral pulmonary zones [57] . Lung ultrasonography can be used for quick valuation of the severity of SARS-CoV-2 pneumonia, to track the evolution of disease during follow-up and to monitor lung recruitment manoeuvres. Additionally, ultrasonography can track the response to prone-position ventilation and the controlling of extracorporeal membrane therapy [17] . Major advantages are the safety of lung ultrasonography, its repeatability and low cost [39, 51] . With enlarged use of bedside ultrasonography in the ICU, patients can be protected from needless radiation and therapy delays. CT may be reserved for follow-up in cases where lung ultrasonography is unable to answer the clinical question. The transport of high-risk patients to CT examinations, with its associated hazards, can be decreased by increasing use of lung ultrasonography. WHO declares COVID-19 a pandemic A novel coronavirus from patients with pneumonia in China COVID-19-what should anaethesiologists and intensivists know about it? Contrastenhanced ultrasound in patients with COVID-19: pneumonia, acute respiratory distress syndrome, or something else? Could the use of bedside lung ultrasound reduce the number of chest x-rays in the intensive care unit? The effect of point-ofcare ultrasonography on imaging studies in the medical ICU: a comparative study 2020) Chest CT findings in patients with corona virus disease 2019 and its relationship with clinical features Relation between chest CT findings and clinical conditions of coronavirus disease (COVID-19) pneumonia: a multicenter study CT features of coronavirus disease 2019 (COVID-19) pneumonia in 62 patients in Wuhan, China Clinical and high-resolution CT features of the COVID-19 infection: comparison of the initial and follow-up changes Chest CT manifestations of new coronavirus disease 2019 (COVID-19): a pictorial review COVID-19 pneumonia: CT findings of 122 patients and differentiation from influenza pneumonia Chest CT features associated with the clinical characteristics of patients with COVID-19 pneumonia COVID-19 patients and the Radiology Department-advice from the European Society of Radiology (ESR) and the European Society of Thoracic Imaging (ESTI) Critical care in the emergency department: patient transfer Chinese Critical Care Ultrasound Study Group (CCUSG) (2020) Findings of lung ultrasonography of novel corona virus pneumonia during the 2019-2020 epidemic CT evaluation of the anterior mediastinum: spectrum of disease Computed tomography-an increasing source of radiation exposure Advances in the diagnosis and treatment of acute pulmonary embolism Comparative diagnostic performances of auscultation, chest radiography, and lung ultrasonography in acute respiratory distress syndrome The risk of cumulative radiation exposure in chest imaging and the advantage of bedside ultrasound Image-guided management of COVID-19 lung disease Thoracic ultrasonography: a narrative review International evidencebased recommendations for point-of-care lung ultrasound Lung sonography Ultrasound of the pleurae and lungs Why look for artifacts alone when the original is visible? Persistent pulmonary congestion before discharge predicts rehospitalization in heart failure: a lung ultrasound study Lung ultrasound: a new tool for the cardiologist Ultrasound assessment of antibiotic-induced pulmonary reaeration in ventilator-associated pneumonia Experimental and clinical experiences in the use of ultrasound for the early detection of pulmonary emboli: a preliminary report Transmission of ultrasound through living human thorax BLUE-protocol and FALLS-protocol: two applications of lung ultrasound in the critically ill Harrison's principles of internal medicine, 16th edn American College of Chest Physicians/La Société de Réanimation de Langue Française statement on competence in critical care ultrasonography Intensive use of general ultrasound in the intensive care unit. Prospective study of 150 consecutive patients Pleural procedures and thoracic ultrasound: British Thoracic Society Pleural Disease Guideline German recommendations on lung and thoracic ultrasonography in patients with COVID-19 Value of lung ultrasound in emergency and intensive care medicine Chest ultrasonography in the ICU Lung ultrasound in the critically ill Lung ultrasound (in the critically ill) superior to CT: the example of lung sliding Lung ultrasound for anesthesia, intensive care and emergency medicine Lung ultrasonography and cardiac surgery: a narrative review The comet tail artifact Lung ultrasonography in COVID-19 pneumonia Lung B-line artefacts and their use Significance of thoracic and lung ultrasound in thoracic surgery The sound of air: point-of care lung ultrasound in perioperative medicine Benefits, open questions and challenges of the use of Ultrasound in the COVID-19 pandemic era The views of a panel of worldwide international experts ASE statement on point-ofcare ultrasound during the 2019 novel coronavirus pandemic Guidelines for cleaning and preparing external-and internal-use ultrasound probes between patients, safe handling, and use of ultrasound coupling gel. American Institute of Ultrasound in Medicine website Ultrasound machine and transducer cleaning Infection prevention and control in ultrasound-best practice recommendations from the European Society of Barriers and facilitators to standardization of ultrasound use and probe disinfection in the ambulatory setting A clinical study of noninvasive assessment of lung lesions in patients with coronavirus disease-19 (COVID-19) by bedside ultrasound Ultrasound assessment of lung aeration loss during a successful weaning trial predicts postextubation distress Performance of radiologists in differentiating COVID-19 from viral pneumonia on chest CT The Division of Perinatology, Society of Pediatric, Chinese Medical Association et al (2019) New guidelines for ultrasonic diagnosis of neonatal lung diseases Lung ultrasound for critical care physiotherapists: a narrative review A preliminary study on the ultrasonic manifestations of peripulmonary lesions of non-critical novel coronavirus pneumonia (COVID-19 Potential errors in the diagnosis of pericardial effusion on trauma ultrasound for penetrating injuries Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations Study conception and design were done by DAC, AB, PSS. Acquisition of data was done by DAC. Analysis and interpretation of data were done by DAC, PSS, MP. Drafting of manuscript was performed by DAC, AB, PSS, Critical revision was done by AB, NB, DAC, CE, AL, VM, MP, PR. All authors read and approved the final manuscript. The authors declare that this article has not received funding. Image data are stored in the local PACS at the University of Munich. The analysis of retrospective data was approved by the local ethic committee (Nr. 20-145) at the University of Munich. Not applicable. Adrian P. Brady is member of the Insights into Imaging Editorial Board. He has not taken part in the review or acceptance process of this article. The remaining authors declare that they have no competing interests.