key: cord-1039076-zhi088zl authors: Melo Costa, M.; Benoit, N.; Dormoi, J.; Amalvict, R.; Gomez, N.; Tissot-Dupont, H.; Million, M.; Pradines, B.; Granjeaud, S.; ALMERAS, L. title: Saliva, a relevant alternative sample for SARS-CoV2 detection date: 2020-11-30 journal: nan DOI: 10.1101/2020.11.27.20239608 sha: c9545842c98d47858635c345b4b41dfd3146ae70 doc_id: 1039076 cord_uid: zhi088zl Background: Currently, COVID-19 diagnosis relies on quantitative reverse-transcriptase polymerase chain reaction (RT-qPCR) from nasopharyngeal swab (NPS) specimens, but NPSs present several limitations. The simplicity, low invasive and possibility of self-collection of saliva imposed this specimen as a relevant alternative for SARS-CoV-2 detection. However, the discrepancy of saliva test results compared to NPSs made of its use controversial. Here, we proposed to assess Salivettes, as a standardized saliva collection device, and to compare SARS-CoV-2 positivity on paired NPS and saliva specimens. Methods: A total of 303 individuals randomly selected among those investigated for SARS-CoV-2 were enrolled, including 30 (9.9%) patients previously positively tested using NPS (follow-up group), 90 (29.7%) mildly symptomatic and 183 (60.4%) asymptomatic. Results: The RT-qPCR revealed a positive rate of 11.6% (n=35) and 17.2% (n=52) for NPSs and saliva samples, respectively. The sensitivity and specificity of saliva samples were 82.9% and 91.4%, respectively, using NPS as reference. The highest proportion of discordant results concerned the follow-up group (33.3%). Although in the symptomatic and asymptomatic groups the agreement exceeded 90.0%, 17 individuals were detected positive only in saliva samples, with consistent medical arguments. Conclusion: Saliva collected with Salivette demonstrated more sensitive for detecting symptomatic and pre-symptomatic infections. In December 2019, a pneumonia outbreak caused by a novel coronavirus, Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), emerged in Wuhan, China. Since this disease has spread quickly worldwide causing the Coronavirus Disease 2019 [1]. In March 2020, this novel coronavirus has been considered as pandemic [2, 3] . Breaking the chain of disease transmission was a strategy promoted by the World Health Organization (WHO) to control this health crisis. The extensive screening was recommended in order to isolate and to treat infected cases. Different biological specimens were tested for SARS-CoV-2 detection including upper and lower respiratory tracts, urinary, blood or fecal samples [4, 5] . These screening tests are currently carried out by quantitative reverse transcription polymerase chain reaction (RT-qPCR) using mainly nasopharyngeal or oropharyngeal samples [6] . Although nasal/throat swabs remain the gold standard test, this collecting process causes discomfort to patients and may conduct to patient sneezing and coughing, exposing healthcare workers to viral droplets. The aerosol dispersal of SARS-CoV-2 represents a considerable risk for healthcare professionals [7] . This uncomfortable sampling method is relatively invasive and nose bleeding might also occur. Moreover, nasal swab is contraindicated for people with blood clotting diseases or deviated septum [8] . Swab sampling is technically not evident to succeed systematically, notably on very young children or self-collection [9, 10] . Then, swab test sensitivity is suboptimal, and the recourse to repeat sampling is not infrequent [11] . The validation of a simple and noninvasive sampling method for SARS-CoV-2 diagnosis became on demands. Saliva was then rapidly assessed as an alternative specimen to diagnose 13] . Saliva presents numerous advantages, notably low invasive collection, easy to handle with the possibility of self-collection, permitting mass testing and exposure prevention of were collected uniquely after the understanding of the study protocol and consent acknowledgement by the participants. Individual recruitment. During the period of 6 th October 2020 to 16 th October 2020, individuals admitted to the Institut Hospitalo-Universitaire (IHU) Méditerranée Infection (Marseille, France), for SARS-CoV-2 routine diagnosis, were invited to enroll in the research study. The inclusion criteria were all individuals on demand of SARS-CoV-2 detection using NPS, accepting in parallel, saliva collection. Individuals under 18 years old, non-French speaking, pregnant women and individuals suffering of Gougerot-Sjögren Syndrome were excluded. NPS management. A standard protocol was used for NPSs collection using nasal swabs with viral transport medium (Pacific Laboratory Products, Blackburn, Australia). Routine diagnosis protocol was applied for SARS-CoV-2 detection on NPS samples by 24] . Saliva collection. Each participant should not have eaten or drink anything in the 30 minutes prior the saliva collection. Saliva was collected using cotton roll (Neutral Salivettes®, SARSTEDT, Numbrecht, Germany) under the supervision of a laboratory technician. The cotton roll was directly introduced in the mouth without handling and then kept 2 min in the mouth's participant who soaked the cotton by doing circular movements, prior to replace it into stopper part of the Salivette® tube. The samples were refrigerated on ice at the collection site and stored in these conditions until they arrived in the laboratory. The storing time never exceeded 6 hours. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 30, 2020. ; https://doi.org/10.1101 https://doi.org/10. /2020 Saliva sample preparation. Salivettes® were centrifuged at 1500× g for 2 min at 4 °C and retrieved saliva was transferred to 1.5 mL tubes. Two hundred microliters were collected for molecular analysis and the remaining volume was preserved as rescue sample. All samples were stored at -80°C until their use. If the retrieved saliva volume was less than 150µL, 500µL of ultra-pure water were loaded at the top of the cotton roll. Salivette® was then, once again, centrifuged at 1500 × g for 2 min at 4 °C and processed as indicated above. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 30, 2020. ; https://doi.org/10.1101 https://doi.org/10. /2020 positives by saliva samples were informed by phone messages, and invited to perform a retest. Moreover, an examination of SARS-CoV-2 screening history was done for these participants. Human RNase P RT-qPCR. RT-qPCR using the Human RNase P (HRNP) primers/probe sets were performed as previously described [27] , for all saliva samples in order to ensure the quality of the extraction, mainly in the samples with water addition. Statistical analysis. Statistical analyses were performed using the GraphPad Prism software 7.0.0 (GraphPad Software, San Diego, USA). A total of 303 sample pairs of NPSs and saliva samples were collected. The characteristics of the participants were detailed in the Table 1. The median age was 40 years (interquartile range, 29-50; range, 18-78 years). One hundred and forty-four individuals (47.5%) were men. Concerning the symptoms, although the median onset (IQR) was 0 day (0-2.5), more than one third of the participants (n=104, 34.3%) presented symptoms at the enrolment day. The more common symptoms at presentation were fever (n=39, 12.9%), myalgia (n=31, 10.3%) and headache (n=24, 7.9%), corresponding to flu symptoms, followed by cough (n=21, 6.9%) and anosmia/ageusia (n=20, 6.6%) which were frequently reported in Covid-19 clinical diagnosis criteria [28, 29] . Paired sample analyses revealed that the positive rate of SARS-CoV-2 screening by RT-qPCR for NPSs and saliva samples were 11.6% (n=35) and 17.2% (n=52), respectively. Among them, 29 participants were classified as positives using both specimens, and 6 and 23 were classified . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 30, 2020. ; https://doi.org/10.1101 https://doi.org/10. /2020 positively for SARS-CoV-2 only by NPSs or saliva, respectively ( Figure 1A) were considered, or if paired positive samples (p>0.05, Wilcoxon test, Figure 1B) were taken into account. To determine the screening test performance of RT-qPCR on saliva samples, the results from the NPSs were used as reference. The sensitivity and specificity of saliva samples were, respectively, of 82.9% and 91.4% (Table 2 ). The assessment of concordance RT-qPCR results between paired specimens revealed an agreement of 90.4% with a Cohen's κ coefficient of 0.652 corresponding to a substantial agreement of the data [30] . Among the enrolled volunteers, 30 participants were previously positively tested for SARS-CoV-2 by RT-qPCR on NPSs and came to follow their viral load (follow-up group, n=30; 9.9%). The delay between the previous NPS SARS-CoV-2 positive tests and the present sampling ranged from 4 to 10 days. The remaining participants were separated into mildly symptomatic (n=90; 29.7%) and asymptomatic (n=183; 60.4%) groups ( . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 30, 2020. ; https://doi.org/10. 1101 /2020 Chi-square test), 24.4% (n=22) and 30.0% (n=27) for the symptomatic group (p>0.05, Chisquare test), and 3.8% (n=7) and 9.3% (n=17) for the asymptomatic group (p<0.05, Chi-square test, Table 3 ). In all groups, the positive rate was higher in saliva samples than in NPSs, and this difference was significantly increased for the asymptomatic group. In the follow-up group (n=30), discordant results were obtained for one third (n=10) of the tested specimens leading to low sensitivity (50.0%) and specificity (75.0%) for saliva samples compared to NPSs (Table 3) . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 30, 2020. ; For the asymptomatic group, a sensitivity and specificity of 100% and 94.3%, respectively, was obtained for saliva samples compared to NPSs (Table 3 ). The agreement proportion reached to 94.5% with a Cohen's κ coefficient of 0.559 corresponding to moderate agreement. Ten asymptomatic participants were detected SARS-CoV-2 positive uniquely in saliva samples (Ct values ranging from 20.9 to 34.0). For three of those ten participants, flu symptoms appeared three or four days after the positive saliva test (Additional File 1). Two out of those three performed a new NPS test and were both positives (Ct values of 21.6 vs 32.8 three days before in saliva and 23.9 vs 20.9). Among the remaining seven of those ten participants, the partners of two participants were tested positive by NPSs two and six days before. No information was obtained from the five remaining participants positively detected by saliva samples. The analyses of clinical data and phone contacts supported that more than half of the discordant results (n=18; 62.1%) were likely true positive. The absence of complementary information from the remaining 11 participants did not allowed us to adjudicate on their infectious status. If we consider as true positive any participants with either a NPS or a saliva positive tests, the total number of positives samples was 58, corresponding to a positive rate of 19.1% (Table 4 ). In these conditions, the overall proportion of agreement of SARS-CoV-2 screening for saliva . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 30, 2020. ; 1 1 To control whether the addition of ultra-pure water to saliva samples could be detrimental for RNA detection, a comparison of Ct values from HRNP between the 34 saliva samples with addition of ultra-pure water, and 269 remaining saliva samples was performed. No HRNP amplification was obtained for one saliva sample with water addition, whereas, the failing of PCR products in four saliva samples, which did not required water addition, was observed. HRNP Ct values from saliva samples with water addition were significantly lower than those without water addition (p<0.003, Mann-Whitney test, Additional File 2A). Nevertheless, among the 34 saliva samples filled up with ultra-pure water, SARS-CoV-2 was detected in five samples (Ct values ranging from 29.9 to 34.0). HRNP products were obtained for these five samples (Ct values ranging from 26.7 to 33.2). Among them, one participant, positively detected for SARS-CoV-2 using saliva (Ct value: 29.9), was also corroborated by the NPS specimen (Ct value: 33.9). These results indicated that, despite water addition decreased detection of human RNA cellular control, SARS-CoV-2 detection was not compromised by saliva dilution. The non-access of NPS specimens did not allowed to assess HRNP detection, and then to conclude whether miss-detection in NPSs was attributed to improper sampling (no PCR product) or to insufficient local viral titers (lower than detection limit). Interestingly, the HRNP was detected in the 52 SARS-CoV-2 saliva samples and no significant difference of HRNP Ct values was observed between positives and negatives SARS-CoV-2 saliva samples (p>0.05, Mann-Whitney test, Additional File 2B). Moreover, HRNP was detected in the 6 saliva samples (Ct values ranging from 29.9 to 33.9), for which respective NPS specimens were found SARS-CoV-2 positives. The miss-detection of the coronavirus in these saliva samples was not due to RNA extraction impairment. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 30, 2020. ; https://doi.org/10.1101/2020.11.27.20239608 doi: medRxiv preprint In the present study, Salivette® devices were chosen to standardize saliva collection. For an accurate comparison of saliva and NPS specimens, the same extraction method and RT-qPCR systems, with identical experiment control and validation criteria, were used. Overall, the present study confirmed the relevance of the saliva sampling for SARS-CoV-2 detection in the 303 individuals under investigations, with a concordance to NPSs exceeding 90%, that was among the more efficient [19] . Nevertheless, among the 58 participants classified SARS-CoV-2 positive either by NPS and/or saliva tests, discordant paired detection represented half of them (n=29). Most of the discordant pairs were detected positive only in saliva samples (79.3%, 23/29). Investigations based on clinical history analyses and patient phone contacts revealed a confirmation or supportive data of SARS-CoV-2 infection for 60.9% of them (14/23). The lack of data hampered to conclude on the SARS-CoV-2 status of the remaining participants. If any participant with either a NPS or a saliva positive tests is considered a true positive, as it is frequently done [31, 32] , the PPA was incontestably significantly higher for saliva than in NPS, which was consistent with previous works reporting an increased sensitivity of saliva specimens [33] [34] [35] [36] . The absence of significant differences in SARS-CoV-2 Ct values, when all positives or paired positive specimens were compared, confirms that the increased sensitivity could not be attributed to an improved detection of the virus in saliva. The inconsistency of NPS sampling that induces false negatives seems to be a recurrent phenomenon especially in patients with a low viral load [37] , frequently reported during serial testing [11, 38, 39] or in early stage of infection [40] . . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 30, 2020. ; To limit false negative detection, RNA template or synthetic RNA were proposed as external controls for the proper extraction and amplification [41] . However, these external RNAs did not insure a proper sample collection nor the integrity of the RNA sample [24, 27, 42] , and the use of a human RNA cellular control was proposed. The US CDC proposed to use HRNP as a control of proper sampling, sample preservation and extraction [43] . In our study, we did not access to the NPS samples of the routine diagnosis, then it was no possible to control whether the discordance between NPS and saliva specimens was attributed to a RNA integrity failure or a miss-detection of the virus. Conversely, the amplification of the HRNP in the saliva samples from participants classified positive by NPS tests, underlined that the miss-detection seems more attributed to an absence or a sub-detection of the virus rather a problem of saliva collection. The systematic used of human RNA cellular control is mandatory whatever the sampling sources to improve results interpretation. Although, the risk to fail saliva sampling seems less frequent than for NPSs, in a recent study assessing the efficiency of Salivette® for screening SARS-CoV-2 hospitalized cases, 12.2% (6/49) of patients were excluded for lack of enough saliva volume [32] . The sialadenitis, an acute inflammation of salivary glands reported in COVID-19 patients, could conduct to a decrease of salivary flow compromising saliva collection [44] . We observed an insufficient volume of saliva in 11.2% of the samples (n=34). The large majority of these individuals (29/34; 85.3%) were tested SARS-CoV-2 negative in saliva, suggesting that, here, lower salivation could not be attributed to viral infection. Concerning the human cellular RNA control, adding water did not impair the detection of the HRNP. Although significant differences of HRNP Ct values were noticed between diluted and not diluted saliva samples, the SARS-CoV-2 detection in five saliva specimens underlined that viral detection seems not altered by diluting saliva. The water addition . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 30, 2020. ; 1 4 at the top of cotton roll allowed to recover most of the saliva samples (n=33/34, 97.1%), for which HRNP was detected. Finally, water addition did not compromised RNA detection and the RNA integrity control allows to reduce false negative detection. The saliva tests were also compared to NPSs according to clinical history and symptomatology of individuals. A weak agreement was observed in the follow-up group. As patients from this group were convalescent, their viral charge is decreasing [12] , and then miss-paired viral detection could occurred. Among them ten discordant detection, four could be considered as non-contagious based on Ct values from paired samples (3538 were not presented. Paired samples detected at a non-infectious level (350.05, Mann-Whitney test). Bars represent the median and 95% CI. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 30, 2020. ; Table 1 . Characteristics of participants under investigation for COVID-19 diagnosis by paired NPSs and saliva samples. Follow-up* Symptomatic Asymptomatic Others, n (%) 3 (1.0%) 1 (3.3%) 2 (2.2%) / * Previously tested positively for SARS-CoV-2 by RT-qPCR on NPSs. Abbreviations: IQR, interquartile range; NPS, nasopharyngeal swab; SARS-CoV-2, severe acute respiratory syndrome coronavirus 2; SD, standard deviation. . It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 30, 2020. ; https://doi.org/10. 1101 /2020 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 30, 2020. ; https://doi.org/10. 1101 /2020 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 30, 2020. ; Onset of symptoms before the test (days), median (IQR)