key: cord-1038774-2r7njqih authors: Meng, Yuanli; Zhu, Shuangshuang; Xie, Yuji; Zhang, Yanting; Qian, Mingzhu; Gao, Lang; Li, Meng; Lin, Yixia; Wu, Wenqian; Wang, Jing; Yang, Yali; Lv, Qing; Zhang, Li; Li, Yuman; Xie, Mingxing title: Prognostic Value of Right Ventricular 3D Speckle-Tracking Strain and Ejection Fraction in Patients With HFpEF date: 2021-06-30 journal: Front Cardiovasc Med DOI: 10.3389/fcvm.2021.694365 sha: d8701769ec07cb5a0cd99e7678bb28f55b393c7e doc_id: 1038774 cord_uid: 2r7njqih Background: Right ventricular longitudinal strain of free wall (RV FWLS) assessed by two-dimensional speckle-tracking echocardiography (2D-STE) is recognized as an independent predictor of poor prognosis in patients with heart failure with preserved ejection fraction (HFpEF). However, the prognostic implications of three-dimensional STE (3D-STE) parameters in patients with HFpEF have not been well-established. The purpose of our study was to determine whether 3D-STE parameters were the more powerful predictors of poor outcomes in HFpEF patients compared with 2D-STE indices. Methods: Eighty-one consecutive patients with HFpEF were studied by 2D-STE and 3D-STE. RV volumes, ejection fraction (EF) and 3D-RVFWLS were measured by 3D-STE. 2D-RVFWLS was determined by 2D-STE. Patients were followed for the primary end point of heart failure (HF)-related hospitalization and death for HF. Results: After a median follow-up period of 17 months, 39 (48%) patients reached the end point of cardiovascular events. Compared with HFpEF patients without end-point events, those with end-point events had lower RVEF and 3D-RVFWLS (P < 0.05). Separate multivariate Cox regression analyses revealed that 3D-RVFWLS (HR 5.73; 95% CI 2.77–11.85; P < 0.001), RVEF (HR 3.47; 95% CI 1.47–8.21; P = 0.005), and 2D-RVFWLS (HR 3.17; 95% CI 1.54–6.53; P = 0.002) were independent predictors of adverse outcomes. The models with 3D-RVFWLS (AIC = 246, C-index = 0.75) and RVEF (AIC = 247, C-index = 0.76) had similar predictive performance for future clinical events as with 2D-RVFWLS (AIC = 248, C-index = 0.74). Conclusions: 3D-STE parameters are powerful predictors of poor outcomes, providing a similar predictive value as 2D-STE indices in patients with HFpEF. These findings support the potential of RV 3D-STE to identify HFpEF patients at higher risk for adverse cardiac events. Heart failure with preserved ejection fraction (HFpEF) accounts for half of heart failure (HF) patients and has been established as a major cause of cardiovascular mortality (1) . Prior studies have demonstrated that right ventricular (RV) dysfunction is a powerful predictor of mortality and morbidity in patients with HFpEF (2) (3) (4) . Accurate evaluation of RV function is highly desired for the treatment of these patients. Echocardiography, as a non-invasive and widely available technique, has been demonstrated to be a good first-line tool for the evaluation of cardiac function. However, accurate assessment of RV function using conventional echocardiography remains challenging owing to the RV complex structure. The conventional RV function echocardiographic parameters recommended by guidelines, which include RV fractional area change (RVFAC), tricuspid annular myocardial tissue Doppler velocities (S ′ ), and tricuspid annular plane systolic excursion (TAPSE), have its own limitations (5, 6) . Recently, two-dimensional (2D) speckle tracking echocardiography (STE) has been considered to be a sensitive, reliable quantitative technique for RV function assessment (7) (8) (9) . Furthermore, growing evidence suggests that RV longitudinal strain of free wall (RV FWLS) derived from 2D-STE provides incremental prognostic information over standard RV parameters in varying clinical settings, including patients with pulmonary arterial hypertension, HF with reduced ejection fraction, or coronavirus disease-2019 (10) (11) (12) . However, 2D-STE analysis has some primary limitations, such as foreshortened views, geometric modeling, and out-of-plane motion of the speckles. Moreover, 2D-STE evaluation is only available in the apical four-chamber view, precluding the assessment of RV outflow portions. Three-dimensional (3D) STE has been introduced as a novel technique that allows an accurate and comprehensive assessment of ventricular function due to overcoming the aforementioned limitations (13, 14) . To our knowledge, the prognostic value of 3D-STE in patients with HFpEF has not been described. Accordingly, the aims of our study were to assess RV systolic function in patients with HFpEF using 2D-and 3D-STE and determine whether 3D-STE parameters provide similar predictive values as 2D-STE indices. A total of 93 consecutive patients with HFpEF referred to Wuhan Union hospital between March 2016 and December 2018 were enrolled in our study. HFpEF was defined according to Abbreviations: 2D, two-dimensional; 3D, three-dimensional; FAC, fractional area change; HFpEF, heart failure with preserved ejection fraction; HF, heart failure; HFrEF, heart failure with reduced ejection fraction; LVEF, left ventricular ejection fraction; RV, right ventricular; RVEDV, right ventricular end-diastolic volume; RVESV, right ventricular end-systolic volume; RVEF, right ventricular ejection fraction; RVFWLS, longitudinal strain of the right ventricular free wall; STE, speckle-tracking echocardiography; S ′ , tricuspid lateral annular systolic velocity; TAPSE, tricuspid annular plane systolic excursion. All subjects underwent comprehensive transthoracic 2D, Doppler, and 3D echocardiographic examination using commercially available systems (Philips iE33; Philips Medical Systems, Andover, MA, USA). All participants were placed in the left lateral position, and the electrocardiography was recorded simultaneously. During end-expiratory breath holding, 2D and 3D images were obtained. All of the echocardiographic parameters were measured three times, and the mean value was used for the statistical analysis. Cardiac chamber sizes, and LV and RV function were measured based on the guidelines of the American Society of Echocardiography (6) . Left atrial (LA) volume was measured from the apical four-and two-chamber views. LV mass was calculated from the parasternal view on the basis of Devereux's formula. LVEF was obtained by biplane Simpson's method. LV diastolic function was assessed using the ratio of early transmitral flow velocity (E) to early diastolic septal tissue velocity (e ′ ) in the apical four-chamber view. RV basal and mid transverse diameters, and longitudinal dimension, were determined from the apical four-chamber view. RV end-diastolic and end-systolic areas were measured from the apical fourchamber view to calculate RVFAC. RVFAC was calculated as [(RV end-diastolic area-RV end-systolic area)/RV end-diastolic area] × 100%. TAPSE was obtained using M-mode echocardiography of the lateral annulus. S ′ was assessed using tissue Doppler imaging from the apical four-chamber view. Pulmonary artery systolic pressure (PASP) was estimated from peak tricuspid regurgitation jet velocity, using the simplified Bernoulli equation and combining this value with an estimate of the right atrial pressure. Right atrial pressure was estimated from the inferior vena cava diameter and its respiratory changes. 2D grayscale images were obtained for the subjects using the RV-focused apical four-chamber view at frame rates of 50-90 frames/s. All of the images were digitally stored for offline analysis using commercially available software (2D Cardiac Performance Analysis 1.2; TOMTEC Imaging Systems GmbH, Unterschleissheim, Germany). The RV endocardial border was manually traced in the end-systolic frame when the endocardial border was the clearest during the cardiac cycle. The region of interest (ROI) in each image was automatically generated. The software then automatically tracked the speckle patterns in the myocardium frame by frame. The position of ROI and its width were adjusted manually when the speckle tracking appeared to be poor. Finally, the software automatically generated the RV longitudinal strain curves, in which the peak longitudinal strain of each segment was measured. 2D RVFWLS (2D-RVFWLS) was calculated as the average value of the basal, middle, and apical segments of the RV free wall. 3D echocardiographic acquisitions were obtained using the RV-focused apical four-chamber view in full-volume mode with volume rates of 20-35 volumes/s. The 3D full-volume data sets combining four subvolumes were analyzed using 3D speckle tracking software (4D RV Analysis, version 2.0; TOMTEC Imaging Systems GmbH, Unterschleissheim, Germany). The selected 3D data sets were displayed as multiplanar reconstruction images containing three standard longaxis views of the left ventricle (apical four-chamber, apical two-chamber, and apical three-chamber), two long-axis views of the right ventricle (apical four-chamber and apical twochamber), and a RV short-axis view. In the apical four-and two-chamber views, the largest apical long-axis dimensions were set by the point of the LV apex and the center of the mitral annular line. In the apical three-chamber view, the operator set the landmarks corresponding to the aortic annulus diameter (AV1-AV2, Figure 1A ). The point of the RV apex and the center of the tricuspid annular line were obtained in the RV apical four-chamber and coronal views. In the RV short-axis view, the distance between anterior and posterior junctions of the RV free wall with the interventricular septum and the distance of the septum-to-RV free wall were set ( Figure 1A) . The software automatically tracked the RV contours throughout the entire cardiac cycle, which was manually modified if necessary ( Figure 1B) . The software finally generated an RV volume curve, RV end-diastolic volume (RVEDV), RV end-systolic volume (RVESV), RV ejection fraction (RVEF), and 3D RVFWLS (3D-RVFWLS) ( Figure 1C ). 3D-RVFWLS was calculated as the average value of three segments of the RV free wall. Patients were prospectively followed until December 2020. Follow-up information was obtained by clinical visits or by telephone contacts with the patients or their relatives. The end points consisted of death for HF or rehospitalization due to worsening of HF. Continuous numeric variables are reported as mean ± SD or median (interquartile range) and were compared using a two-sample Student's t-test for normally distributed data or the Mann-Whitney U-test for non-normally distributed data. The Kolmogorov-Smirnov-test was used to determine the data distribution. Categorical variables are reported as numerical values and percentage and were compared using the Chi-square test or the Fisher exact-test. Correlation analysis was performed using the Pearson correlation coefficient. The receiver operator characteristic (ROC) curves were used to determine the optimal cutoff value of RV function indices for the detection of poor outcomes. Univariable and multivariable Cox proportional-hazard models were used to determine the predictors of unfavorable clinical outcomes. The following covariates were included in the univariate analyses: age, sex, blood pressure, heart rate, NYHA class, comorbidities, laboratory findings, and conventional LV and RV function, 2D-STE, and 3D-STE parameters. To avoid both the multi-collinearity among RV measurements and overfitting issues, a separate Cox proportional-hazard model including clinical variables and one of the RV function parameters (RVFAC, RVEF, 2D-RVFWLS, or 3D-RVFWLS) was used to determine the independent predictors of adverse outcomes. Model performance was assessed using the Akaike information criterion (AIC) and the C-index. Survival curves were obtained using the Kaplan-Meier method. The log-rank test was used to estimate the differences between the two groups. Statistical analyses were performed using SPSS for Window version 17.0 (SPSS, Inc., Chicago, IL, USA), MedCalc software (Version 19.0.4, Ostend, Belgium), and R software (version 3.6.3, R Foundation for Statistical Computing, Vienna, Austria). Two-sided P-values < 0.05 were considered statistically significant. Intra-observer variability and inter-observer variability were assessed in 20 randomly selected patients with HFpEF. Intraobserver variability was determined by having one observer remeasure after 2 months. Inter-observer variability was determined by a second observer who was blinded to the first observer's measurements. Intra-observer and inter-observer reproducibility were evaluated by means of intra-class correlation coefficient (ICC) and Bland-Altman analysis. RVEF was moderately correlated with 3D-RVFWLS (r = 0.69; P < 0.001) and weakly with 2D-RVFWLS (r = 0.34; P < 0.001) and RVFAC (r = 0.37; P < 0.001) (Figures 2A-C) . Furthermore, 3D-RVFWLS correlated better than 2D-RVFWLS and RVFAC with RVEF (0.69 vs. 0.34; P = 0.001; 0.69 vs. 0.37; P = 0.002; respectively). In addition, a weak correlation between 3D-RVFWLS and 2D-RVFWLS was observed in our study (r The median follow-up time was 17 (11-36) months. A total of 39 (48%) patients reached the end point of events: 6 (15%) patients died, and 33 (85%) were hospitalized for worsening HF. The clinical and echocardiographic characteristics in HFpEF patients with/without end-point events are depicted in Table 1 . 3D-STE, 2D-STE, and hemodynamic and conventional RV function parameters were entered into a ROC analysis to evaluate the probability of adverse clinical outcomes. ROC analyses for unfavorable outcomes revealed that 3D-RVFWLS, 2D-RVFWLS, and RVEF were associated with adverse clinical events (Figure 3) . Areas under the curve for 3D-RVFWLS, RVEF, and 2D-RVFWLS were 0.68, 0.69, and 0.66, respectively. We found that 3D-RVFWLS and RVEF have a similar diagnostic performance for detecting adverse outcomes as 2D-RVFWLS (0.68 vs. 0.66, P > 0.05; 0.69 vs. 0.66, P > 0.05). The best cutoff values of 3D-RVFWLS and RVEF for the detection of poor outcomes were −22% (sensitivity, 54%; specificity, 86%) and 46% (sensitivity, 69%; specificity, 71%), respectively. A 2D-RVFWLS cutoff value of −20% had a sensitivity of 59% and a specificity of 78% for identifying end-point events. Kaplan-Meier survival curves stratified by the cutoff values of 3D-RVFWLS, 2D-RVFWLS, and RVEF are presented in Figure 4 . 3D-RVFWLS lower than 22%, 2D-RVFWLS lower than 20%, or RVEF lower than 46% was associated with adverse outcomes. They clearly revealed that event-free survival significantly declined with worsening RV longitudinal strain and RVEF. In Table 3) The intra-observer and inter-observer reproducibility are shown in To the best of our knowledge, this is the first study to comprehensively evaluate the prognostic value of RV function using 2D-and 3D-STE, and conventional echocardiographic indices in patients with HFpEF. The major findings of our study were (1) compared with HFpEF patients without end-point events, those with end-point events had lower RVEF and 3D-RVFWLS, whereas 2D-RVFWLS was not different. (2) 2D-and 3D-RVFWLS, and RVEF were independent predictors of poor outcomes in patients with HFpEF. (3) 3D-STE provided a similar predictive value as 2D-STE parameters in patients with HFpEF. In clinical practice, RV function assessment remains a challenge due to the complex shape and load dependency of the right ventricle. RV myocardial deformation imaging, which is less affected by geometric assumptions and loading conditions than traditional parameters, allows more sensitivity to detect the subclinical ventricular dysfunction in a variety of heart diseases (17) . The previous study showed that RV longitudinal strain using 2D-STE was diminished in patients with HFpEF (18). However, 2D-STE is limited by 2D plane, foreshortened views, and out-of-plane motion of the speckles. The newly developed 3D-STE overcame the aforementioned limitations and could provide the comprehensive evaluation of RV performance. Currently, there are limited data regarding the RV function assessment using 3D STE, which mainly focus on patients with pulmonary hypertension (19) (20) (21) . To our knowledge, this is the first study to evaluate RV performance using 3D-STE in patients with HFpEF. Several mechanisms may be associated with RV dysfunction in patients with HFpEF, including increased pulmonary pressure, subtle LV dysfunction, neurohormonal interactions, and myocardial ischemia of the right ventricle (4, 22) . Patients with HFpEF display an elevated LV filling pressure that leads to an increase in venous pulmonary pressures and hence in RV afterload. Indeed, our study corroborates the unfavorable impact of PASP on RV function, because the association of 2D-and 3D-STE parameters with PASP was noted in the present study. Additionally, although LVEF is preserved in HFpEF patients, there exists evidence of subtle LV systolic dysfunction (23) . Ventricular interdependence could potentially affect RV strain measurement through the interaction of the interventricular septum. In recent years, there are growing data on the prognostic role of RV performance in patients with HF. Among them, RV 2D-STE analysis has been demonstrated to show the capability to quantify RV mechanics and provide prognostic information (10, (24) (25) (26) (27) (28) . In a study of patients with HF with reduced ejection fraction (HFrEF), Motoki et (24) . However, 2D STE has inherent limitations. 3D STE theoretically circumvents the limitations of 2D STE; thus, a direct comparison between RV 2D-and 3D-STE parameters for predicting adverse clinical outcomes is clinically significant. Till now, there are several studies regarding the prognostic value of RV 3D-STE indices in patients with pulmonary hypertension (12, 20, 21) . Moreover, very few studies performed head-to-head comparisons of 2D-STE and 3D-STE in RV function evaluation. Previously, we revealed that 3D-RVFWLS is superior to 2D-RVFWLS in RV function assessment against CMR imaging in a study population with a wide variety of cardiovascular pathologies (29) . Similarly, Nagata et al. demonstrated that LV 3D global LS is the most robust index for predicting adverse cardiac events in severe AS patients with preserved LVEF compared with 2D-STE parameters (30) . To the best of our knowledge, this is the first study to estimate the prognostic significance of RV 3D-STE parameters in HFpEF patients and to directly compare its value with that of the 2D-STE strain. In our study, 2D-and 3D-RVFWLS, and RVEF were independently associated with poor clinical outcomes in patients with HFpEF. Moreover, the multivariate Cox hazard model revealed that 3D-RVFWLS and RVEF had a similar prognostic value as 2D-RVFWLS. Indeed, our study also revealed that patients with events displayed decreased RVEF and 3D-RVFWLS compared with event-free patients. In a large observational study of patients with various cardiovascular diseases, Nagata et al. (31) verified the incremental value of RVEF measured by 3D-STE over other echocardiography parameters including LV systolic and diastolic function for predicting adverse outcomes. However, they did not compare the prognostic value of 3D-RVFWLS and RVEF with that of 2D-STE parameters. We offer the first evidence that 3D-STE parameters were not superior to 2D-STE indices in patients with HFpEF for predicting future adverse outcomes. In summary, our study reinforces and expands the previous observations by demonstrating the usefulness of the RV strain in the risk stratification of patients with HFpEF. The present study not only confirms the prognostic significance of 2D-RVFWLS in patients with HFpEF but also indicates the similar prognostic value of 3D-STE as 2D-STE parameters. Considering that RV dysfunction is a risk factor of poor outcomes, RV function evaluation should be one part of the comprehensive assessment of patients with HFpEF. Although 3D STE has theoretical advantage over 2D-STE, experience of 3D-STE for RV evaluation is limited. Whether or not 3D-STE has superiority over 2D-STE requires clinical validation. Our study demonstrated that the 3D-STE strain is not superior to the 2D-STE strain in predicting adverse clinical outcomes in HFpEF patients. Consequently, our study revealed the important clinical implications because 2D-STE allows wider clinical application than 3D-STE in everyday clinical practice. However, the predictive value of 3D-STE in patients with HFpEF requires to be tested in future studies with a multicenter and large sample size. Our study had some limitations. First, although patients in our study were consecutive, subjects with poor RV echocardiographic images quality were excluded from the analysis. This potentially limits the generalizability of our findings. Second, 3D-STE itself is limited by the low frame rates and suboptimal image quality, which may have effects on strain analysis and tracking quality. However, 3D-STE has been considered as clinically useful in LV function assessment. Third, we assessed only the RV longitudinal strain, rather than circumferential or radial deformation, because RV longitudinal strain plays a crucial role in the overall RVEF, and circumferential and radial strain could not be obtained using the current RV strain analysis software. Fourth, our findings pertain only to the software used in our study and may not extrapolate to other software algorithms because the STE measurements are hindered by the intervendor variability. Fifth, using 3D-STE indices to diagnose the severity of diseases in patients with HFpEF was not performed in our study. Future studies that investigate the diagnostic value of 3D-STE measurements in these patients could be the next step. Finally, this is a single-center study with a relatively limited sample size; future multicenter studies with larger sample sizes are required to determine the prognostic value of 3D-STE in patients with HFpEF. In summary, our study demonstrates that 2D-and 3D-RVFWLS, and RVEF can independently predict adverse clinical outcomes in patients with HFpEF. Moreover, 3D-RVFWLS and RVEF assessed by 3D-STE have similar predictive values as 2D-RVFWLS determined by 2D-STE. Therefore, these results of our study support the potential of RV 3D-STE to identify HFpEF patients at higher risk for adverse events. 3D-STE parameters were powerful predictors of poor outcomes, providing similar predictive values as 2D-STE indices in patients with HFpEF. These findings support the potential of RV 3D-STE to identify HFpEF patients at higher risk for adverse cardiac events. The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation. The studies involving human participants were reviewed and approved by Ethics Committee of Tongji Medical College, Huazhong University of Science and Technology. The patients/participants provided their written informed consent to participate in this study. Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article. Trends in prevalence and outcome of heart failure with preserved ejection fraction Cardiac structure and function and prognosis in heart failure with preserved ejection fraction: findings from the echocardiographic study of the treatment of preserved cardiac function heart failure with an aldosterone antagonist (TOPCAT) trial Right ventricular function in heart failure with preserved ejection fraction: a community-based study Right heart dysfunction in heart failure with preserved ejection fraction Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging Guidelines for the echocardiographic assessment of the right heart in adults: a report from the American Society of Echocardiography endorsed by the European Association of Echocardiography, a registered branch of the European Society of Cardiology, and the Canadian Society of Echocardiography The effect of right ventricular myocardial remodeling on ventricular function as assessed by twodimensional speckle tracking echocardiography in patients with tetralogy of Fallot: a single center experience from China Evaluation of global and regional right ventricular systolic function in patients with pulmonary hypertension using a novel speckle tracking method Assessment of age-related changes in left ventricular twist by two-dimensional ultrasound speckle tracking imaging Prognostic value of right ventricular longitudinal strain in patients with COVID-19 Additional prognostic value of 2D right ventricular speckle-tracking strain for prediction of survival in heart failure and reduced ejection fraction: a comparative study with cardiac magnetic resonance Prognostic value of right ventricular two-dimensional and three-dimensional speckle-tracking strain in pulmonary arterial hypertension: superiority of longitudinal strain over circumferential and radial strain Right ventricular deformation analyses using a three-dimensional speckletracking echocardiographic system specialized for the right ventricle New speckle-tracking algorithm for right ventricular volume analysis from three-dimensional echocardiographic data sets: validation with cardiac magnetic resonance and comparison with the previous analysis tool ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: the task force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC) Recommendations for the evaluation of left ventricular diastolic function by echocardiography: an update from the european association of cardiovascular imaging Right ventricular function in cardiovascular disease, part II: pathophysiology, clinical importance, and management of right ventricular failure Impaired left ventricular global longitudinal strain in patients with heart failure with preserved ejection fraction: insights from the RELAX trial Utility of three-dimensional global longitudinal strain of the right ventricle using transthoracic echocardiography for right ventricular systolic function in pulmonary hypertension Three-dimensional echocardiography and 2D-3D speckle-tracking imaging in chronic pulmonary hypertension: diagnostic accuracy in detecting hemodynamic signs of right ventricular (RV) failure Three-dimensional speckle tracking of the right ventricle: toward optimal quantification of right ventricular dysfunction in pulmonary hypertension Incremental prognostic value of right ventricular strain in patients with acute decompensated heart failure Impaired systolic function by strain imaging in heart failure with preserved ejection fraction Right ventricular global longitudinal strain and outcomes in heart failure with preserved ejection fraction Importance of ventricular longitudinal function in chronic heart failure Prognostic Significance and Normal Values of 2D Strain to Assess Right Ventricular Systolic Function in Chronic Heart Failure Right ventricular global longitudinal strain provides prognostic value incremental to left ventricular ejection fraction in patients with heart failure Superior prognostic value of right ventricular free wall compared to global longitudinal strain in patients with heart failure Value of 3D versus 2D speckle-tracking echocardiography for RV strain measurement: validation with cardiac magnetic resonance Prognostic value of LV deformation parameters using 2D and 3D speckle-tracking echocardiography in asymptomatic patients with severe aortic stenosis and preserved LV ejection fraction Prognostic value of right ventricular ejection fraction assessed by transthoracic 3D echocardiography The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.Copyright © 2021 Meng, Zhu, Xie, Zhang, Qian, Gao, Li, Lin, Wu, Wang, Yang, Lv, Zhang, Li and Xie. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.