key: cord-1037475-ofx1kpu2 authors: Sanito, Raynard Christianson; You, Sheng-Jie; Wang, Ya-Fen title: Degradation of contaminants in plasma technology: An overview date: 2022-02-15 journal: J Hazard Mater DOI: 10.1016/j.jhazmat.2021.127390 sha: 9df1f7f75a6f215efcca4ab2f307687234b77edd doc_id: 1037475 cord_uid: ofx1kpu2 The information of plasma technologies applications for environmental clean-up on treating and degrading metals, metalloids, dyes, biomass, antibiotics, pesticides, volatile organic compounds (VOCs), bacteria, virus and fungi is compiled and organized in the review article. Different reactor configurations of plasma technology have been applied for reactive species generation, responsible for the pollutants removal, hydrogen and methane production and microorganism inactivation. Therefore, in this review article, the reactive species from discharge plasma are presented here to provide the insight into the environmental applications. The combinations of plasma technology with flux agent and photocatalytic are also given in this review paper associated with the setup of the plasma system on the removal process of metals, VOCs, and microorganisms. Furthermore, the potential of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) inactivation via plasma technology is also described in this review paper. Detailed information of plasma parameter configuration is given to support the influence of the critical process in the plasma system to deal with contaminants. Plasma is the fourth state of matter because of the high temperature, energetic molecules, and state transform of matter on the sequence: solid, liquid, gas, and plasma Fridman (2008) (Gomez et al., 2009) . Molecules of the gas dissociate to another form as the atom of gas, and it moves freely to free charged particles, including electrons, reactive species (radicals, peroxides, super oxides, hydroxyl radical, singled oxygen, alpha oxygen) and positive ions (Hayyan et al., 2016) . Moreover, the presence of free charge carriers confirm that plasmas are electrically conductive and can achieve ultra-high electrical conductivities, for example copper and gold. Also, plasmas generate better energetic species compared to ordinary chemical because of high temperature and energy densities. Furthermore, a chemical reaction from energetic species occurs even at the low temperatures that harder to be obtained by ordinary chemical reaction, giving excited ions, atoms and molecules related to the selective chemical transition (Fridman et al., 1999; Fridman and Kennedy, 2011) . Thereby, plasma technology shows a good opportunity for environmental clean-up applications. The collision of atoms in plasma technology plays a key role for pollutants degradation during the treatment due to high energy atoms Heberlain and Murphy (2008) . The collision of atoms is generated from a chemical reaction between the two electrodes that convert electrical energy to thermal energy. Moreover, the collision occurs from a gas phase environment under a glow discharge with electrons and ions, neutral atoms, molecules, reactive species, and photons (Chapman, 1980; Taylor and Pirzada, 1994; Chang et al., 2009) . The main collision processes are ionization, dissociation, photo-ionization, excitation, relaxation or de-excitation, radiative recombination, ion-neutral collision, and electron attachment (Table 1) . Thereby, the degradation of pollutants during plasma treatment can be obtained during the plasma processes because of the collision of gas phase in the plasma technology. Fig. 1 shows the difference between collision processes in plasma technology. Plasma technology shows a promising result on the environmental clean-up for dealing with contaminants, such as volatile organic compounds (Wessenback, 2016; Chung et al., 2018; Du et al., 2018 Du et al., , 2019 Sanito et al., 2020a) , recalcitrant organic compounds and dyes Zhou et al., 2021a Zhou et al., , 2021b Zhou et al., , 2021c , metals, metalloids (Cubas et al., 2014 (Cubas et al., , 2015 Sanito et al., 2020b Sanito et al., , 2020c , carbon from plastic waste (Sanito et al., 2020b) and microorganism (Santos et al., 2018) , and mostly studies are based on the laboratory scale which are promising to be applied in the real application. Decomposition trichloroethylene (C 2 HCl 3 ), dichloromethane (CH 2 Cl 2 ), 1,1,1-Tricholorethane (C 2 H 3 Cl 3 ), carbon tetra chloride (CCl 4 ), chloroform (CHCl 3 ), carbon tetraflouride (CF 4 ), hexafluoroethane (C 2 F 6 ), and Sulfur hexafluoride (SF 6 ) showed a good progress conducted by corona discharge and dielectric barrier discharge (Du et al., 2018) . An application of atmospheric-microwave plasma bubble reactor for dealing with cefixime, azophloxine, and dyes pollutants have been conducted by , Zhou et al. (2021a) and Zhou et al. (2021b) . The standard operating condition considering discharge power (10-400 W), AC frequency (100-3000 Hz) and peak voltage (10.4-14.4 kV) , in different plasma configuration, such as atmosphericpressure plasma bubble and dielectric barrier discharge. Zhou et al. (2021a) confirmed that single pollutants, namely, methylene blue, orange II, and alizarin yellow can be degraded via the atmosphericpressure plasma bubble. Sanito et al. (2020a) found that the treatment of epoxy resin mixed with CaCO 3 via an atmospheric-pressure microwave plasma showed a good removal rate of benzene and toluene, and Chung et al. (2018) stated that active species plays an integral role in the oxidation that causes reduction of VOC concentration during plasma treatment. The addition of flux agents improves the composition of the OH radicals that responsible for degrading the nitrogen oxide (NOx) (Sanito et al., 2020b) . Cubas et al. (2014) observed that the thermal plasma treatment of galvanic sludge is suitable for eliminating Cr, Fe, and Zn as the same author (Cubas et al., 2015) discovered that reduction of Mn and Zn from the moist paste batteries can be obtained. Furthermore, the addition of quartz sand is considered as the one of parameters that improves the vitrification of material. In the inactivation of microorganism, bacteria such as Escherichia coli, Pseudomonas flourescens (Santos et al., 2018; Mai--Prochnow et al., 2020) , and Pseudomonas aeruginosa (Scally et al., 2018) can be reduced by cold plasma corona discharge, plasma bubble reactor, and dielectric barrier discharge, respectively. Thus, plasma technology is a promising method in many environmental clean-up applications. Recently, plasma technology has been applied to remove pollutants from hazardous waste (Cubas et al., 2015; Sanito et al., 2020a) , wastewater Zhou et al., 2021a Zhou et al., , 2021b , agriculture products, and foods and even generate syngas from the biomass (Muvhiiwa et al., 2018) . The reactive species in plasma system plays an integral role in the degradation of pollutants (Locke and Shih, 2011) . However, the mechanism of pollutant degradation from plasma discharged is directly associated with electricity power, gas flow rates, chemical composition of carrier gases, and electron densities. Also, the main challenge is associated with the lack of knowledge on the quantities of radicals by plasma and its mechanism for further recombination and interaction (Adamovich et al., 2017) . In addition, the fuse of flux agents or catalyst also improves the role reactive species during the degradation of pollutants from the solid waste or wastewater (Wessenback, 2016; Sanito et al., 2020a) . Consequently, the role of reactive species must be fully understood to obtain a good performance during the treatment of contaminants based on each plasma parameters reactors via the plasma systems, for dealing with solid wastes, wastewater, biomass conversion, and inactivation of microorganisms. This review aims to explore the mechanism of reactive species for degrading pollutants and microorganisms from solid waste, wastewater, agriculture products, aerosols, and conversion of biomass to useful gases Excitation is the ionization (or excitation) of an atom by the transfer of the excitation energy from that other atom whose energy is greater than the ionization (or excitation) energy of the other. (1980) product during the treatment in plasma technology from recent publications and literature reviews. Also, the information on plasma technology to convert biomass to syngas is also presented herein. Furthermore, the mechanism on how reactive species destroy VOCs, metals, metalloids, bacteria and virus during various plasma systems. Furthermore, the most important parameters of the plasma system and their effect on the removal of pollutants are also discussed. A detailed review of the literature and the significance of insight reactive species mechanism in plasma technology is explored, and a future outlook is given in this review paper. Information was collected from several journals via science direct and web of science. Reactive species plays a major role in the degradation of pollutants because they create some reactions, namely, acid-base reactions (H 3 O + , HNO 2 , HNO 3 ), oxidation reactions (•H, H 2 O 2 , O 3 , O = NOOH), reduction reactions (•H, •HO 2 ), and photochemical reactions (UV reaction from plasma), and it can be generated from plasma discharged (Lukes et al., 2014; Iervolino et al., 2020; Zhou et al., 2021a Zhou et al., , 2021b Zhou et al., , 2021c Zeghioud et al., 2020) . Nayak et al. (2017) pointed out that the essential species, namely, O 3 , O 2 , NO, N 2 O, NO 2 , NO 3 , and N 2 O 5 , are usually found in the discharges zones. An overview of the transfer process is shown in Fig. 2 . In more precise, based on the electrical discharges in liquid and in gas-liquid environment, reactive species are classified into three types, namely, primary species, secondary species and tertiary species (Lukes et al., 2012) . Reactive species may be formed directly in liquid or bubbles in the liquid and the gas with contact with droplets, aerosols, clusters, and water surfaces. In contact with a solid surface, addition of catalyst or flux agent improves the elimination of pollutants during the process of high energy collision of the atom, such as reactive species in water is recognized as plasma activated water (PAW). Furthermore, the reactive oxygen species (ROS) and reactive nitrogen species (RNS) will be produced from water environment under plasma reaction (Hefny et al., 2016; Nayak et al., 2017) . According to Snoecx et al. (2019) , the trapping of oxygen (O) species and hydrogen (H) species plays an important role in suppressing the nitrogen oxide (NOx) and nitrous oxide (N 2 O) formation. From the study of Li et al. (2019) pointed out that reactive species also might be generated and then combined with photocatalytic reactions through some reactions ((1)− (4)). Thus, reactive species from plasma discharged play an important role to degrade pollutants in plasma technology application. According to Locke and Shih (2011) , reactions of primary and secondary species during the treatment in water can be generated from water (H 2 O), oxygen (O 2 ), and nitrogen (N 2 ). Sanito et al. (2020a) confirmed that the addition of shell powder improved elimination of VOC due to •OH radical composition contained in the shell powder. In addition, Lukes et al. (2014) found that plasma gas discharged at the gas − liquid interface consists of reactive species such as hydroxyl radicals (•OH), nitrogen dioxide (•NO 2 ), nitric oxide radicals (NO radicals) and long-lived chemical products, such as ozone (O 3 ), hydrogen peroxide (H 2 O 2 ), nitrate (NO 3 -), nitric oxide (NO -) and directly depend on the gas atmosphere. Notably, the existence of reactive species is strongly generated by jet discharged. Table 2 shows the classification of reactive species from jet discharges in plasma technology. The operation of plasma to treat waste (solid waste and wastewater), biomass conversion and inactivation of microorganisms should consider several factors related for facilitating plasma discharged, such as electric power, carrier gases, gas flow rate and reaction time. The electric power, type of gases, addition of flux agents and gas flow rates under jet discharge play a dominant role in treating contaminants (Gomez et al., 2009; Cubas et al., 2014; Cubas et al., 2015; Sanito et al., 2020a Sanito et al., , 2020b . In an atmospheric-pressure microwave plasma reactor, higher microwave power with proper control of gas flow rate gives the high energy excitation that is responsible for generating reactive species (Leins et al., 2015) . For creating vitrification, degrading pollutants and generating syngas via thermal plasma or atmospheric-pressure microwave plasma reactor, the addition of flux agents is suggested (Lin et al., 2014; Cubas et al., 2015 Cubas et al., , 2016 Sanito et al., 2020a Sanito et al., , 2020b . Thereby, the different plasma system has different critical parameters for different application. discharges, (b) Micro-plasma bubble reactor, (c). Thermal plasma, (d) Atmospheric-pressure microwave plasma reactor. However, different plasma systems have different support systems for eliminating different contaminants from different sources. For example, atmospheric-pressure microwave plasma configuration requires cooling water system and dielectric barrier discharge is vice versa. The system of thermal plasma is simpler compared to the atmospheric-pressure microwave plasma reactor. Thus, each plasma technology has different system. Table 3 informs a comparison of plasma systems, parameters set-ups, and supporting systems. Some studies have been performed that plasma technology shows a promising result in the elimination of metals and metalloids using The list of reactive species in plasma discharged (Lukes et al., 2012) . (Cubas et al., 2014 (Cubas et al., , 2015 (Cubas et al., , 2016 and atmospheric-pressure microwave plasma reactor (Sanito et al., 2020a (Sanito et al., , 2020c (Sanito et al., , 2021a . Moist paste batteries, galvanic sludge, leachate and epoxy resin, have been treated through a plasma system for eliminating Cr, Fe, Mn, and Zn with flux agents (quartz sand and shell powder) addition. The fuse of quartz sand creates an increased reduction of Ce, Fe and Zn in the galvanic sludge and Mn and Zn in the moist paste batteries. Decreasing of metals and metalloids from galvanic sludge and moist paste batteries strongly depends on the fuse of quartz sand because it creates the silicate network from the Si structure and traps the elements. The addition of flux agent creating the fusion of hazardous waste to form a single entity (Sanito et al., 2020a) . Moreover, plasma leaves through the nozzle causing recombine and gaseous state. As a result, the energy is released. In this case, the elimination of elements occurs, and quartz sand converts to a glassy formation (Cubas et al., 2014) . Zn's reduction also may be obtained at a good result with the fuse of shell powder in the resin because the presence of OH• radicals from shell powder and N metastable atoms from plasma discharges that play a significant role as the catalyst (Sanito et al., 2020a) . Fig. 4a displays the mechanism of element degradation, and Fig. 4b gives the vitrification of pollutants with the addition of the flux agents. According to flame atomic absorption spectroscopy (FAAS) data, Cubas et al. (2014) found that Cr, Fe and Zn eliminations were 100%, 99.6%, and 100%, respectively, in galvanic sludge fuse with the quartz sand during the treatment in the thermal plasma. The flow rate was controlled by 25 L/min ̶ 1 , and 2.4 kW of thermal plasma power, and 12 min of plasma pyrolysis. Cubas et al. (2015) , on their further, research confirmed that removals of Mn and Zn from moist paste battery, respectively, can be obtained by more than 97%, while the quartz sand were added via the thermal plasma in 5 min, using argon gas with the flow rate of 5 L/min ̶ 1 , and 2.4 kW of thermal plasma power. Removal of Zn from resin can be obtained by more than 96%, while the pyrolysis duration was maintained at 5 min with the fuse of shell powder from Babylonia formosae as the flux agents. Furthermore, gas flow rate and microwave power were controlled at 6 L/min and at 900 W, respectively (Sanito et al., 2020a) . Moreover, other analyses using scanning electron microscope (SEM) and X-ray fluorescence (XRF) confirmed the conversion of residue structure of the material with the increasing of Si in the final residue. It confirms that there is a transformation of material in plasma treatment. Sanito et al. (2020a) confirmed that x-ray diffraction (XRD) analysis showed the amorphous structure of final residue. It means that Zn was not detected in the surface of the final residue and is successfully vitrified in the final residue. Thus, an amorphous element cannot be detected via XRD analysis, but it eliminates elements based on the inductively coupled plasma atomic emission spectroscopy (ICP-AES) analysis. Thereby, it can be concluded that degradation of the element occurs due to the reaction of reactive species from the plasma jet. The reaction of Cr, Fe, Mn and Zn combined with SiO 2 and CaCO 3 can be shown as follows: Higher removal of elements is obtained because of the high energy excitation from the plasma jet. Furthermore, the collision of atoms from plasma discharged occurs and is ionized by a high energetic reaction and high temperature. Also, the metastable atom in carrier gas plays the integral role in an ionization of elements' atoms from waste. Owing to this mechanism, harmful elements can be eliminated perfectly (Fridman, 2008; Mattox, 2010) . Thereby, there is a significant decrease in elements. The reactions of elements ionization can be explained as follows: To summarize, the removal of elements via the plasma technology can be considered in the treatment of hazardous waste, and it shows a promising result. Also, it depends on the addition of flux agents, high energies, and metastable atoms. XRD, XRF, and SEM analyses help to confirm the transformation of material due to the addition of flux agent. Vitrification of final residue also can be obtained due to the fuse SiO 2 and CaCO 3 that may fulfill the concept of circular economy (Sanito et al., 2020c) . Plasma technology has been applied for converting the biomass or agriculture waste to hydrogen and methane production, and it creates an opportunity for reducing the environmental impact of petroleum-based fuel and generate a useful syngas product (Chen et al., 2008; Tsai and Chen, 2009; Wang et al., 2010; Lin et al., 2014; Huang et al., 2016; Muvhiiwa, 2018) . In the plasma gasification, the oxidation reaction and conversion reaction occur during the in the plasma reactions. Oxidation reactions can be described as follows (Lemmens et al., 2007) : Conversion reactions can be described as follows: The formation of gases, such as hydrogen (H 2 ), carbon dioxide (CO 2 ), and carbon monoxide (CO) can be formed via the devolatilization, secondary gas reaction, and char gasification. Conversion of cellulose is related to dehydration reaction to form the char where it competes with each other (Lin et al., 2014) . Muvhiiwa et al. (2018) found that temperature plays an integral role in the biomass conversion with the value Bisag et al. (2020) of 82% at 1000 • C, and may prevent the production of tar from the wood pellets. 800 -900 • C of reaction temperature for biomass conversion was recommended by Higman and van der Burgt (2008). Additionally, the use of a water-stabilized arc has a significant effect on the composition and low flow rate plasma generated during gasification (Hrabovsky et al., 2010) . As a consequence, biomass can be converted effectively to syngas. According to Lin et al., 2014 , active cellulose may be decomposed due to competing reactions, generate volatile species and char. Furthermore, volatile products, namely, glycolaldehyde (C 2 H 4 O 2 ), glyoxal (C 2 H 2 O 2 ), acetyldehyde (CH 3 CHO), acetone (C 3 H6O), hydroxymethylfurfural (C 6 H 6 O 3 ), carbon dioxide (CO 2 ), carbon monoxide (CO), methane (CH 4 ), water (H 2 O) and levoglucosan (C 6 H 10 O 5 ) are generated from this process. Then, H 2 gases are generated in a secondary gas-phase pyrolysis reaction through hydrogen abstraction reaction with hydrogen atoms. Formyl radicals (HCO) are formed by the active cellulose and contributed to the most reaction to the CO formation. Bio-molecular reaction plays an integral role in the degradation of formaldehyde (CH 2 O) assisted with HCO. The information of conversion pathway of biomass to hydrogen is shown in Fig. 5 . The reaction of conversion pathway from the biomass is described as follow (Lin et al., 2014) : Active cellulose → C 6 H 10 O 5 (Active decompose cellulose) Cellulose → 5H 2 O + 6 char (Dehydration reaction) Reaction during cellulose degradation can be described as follows: H-atom reactants and the importance of HCO radicals during in the reactions. The H-atom reactants indicate a reaction and formed a HCO radical with the reaction that is mentioned as follows: Total hydrogen (H 2 ) was generated from the experiment. The settings of microwave power were 800 W, 900 W and 1000 W, resulting the total hydrogen production can be obtained by 15.56%, 21.00% and 23.73%, respectively. Higher H 2 can be obtained due to higher microwave power at value of 1000 W, producing high thermal energy responsible for producing high reactive species. It can be shown on the high conversion rate with the value of 67.33%. Moreover, it generates twice as much as hydrogen gas mass compared to 800 W of microwave power. The amounts of H 2 , CO 2 , and CO volume fractions were 90.57%, 91.16%, and 91.25%, respectively. Microwave plasma generated a high energetic electron, responsible for generating free radicals and active species that are released through the electron impact dissociation reaction, penning dissociation reaction, and molecule radical reactions. Thereby, a higher microwave power plays a significant impact in generating high hydrogen production and hydrogen conversion rate (Lin et al., 2014 ). An example of penning ionization can be described as follows: Basu (2010) and Sirkawar et al. (2016) stated that the generated of tar formation is a serious issue because it consists of hydrocarbon and heavy metals. Also, it causes issue related to the quality of the gas product. To solve the problems, thermal cracking, steam reforming, dry reforming, carbon formation, and partial oxidation are suggested to be conducted in the main treatment of plasma gasification. To conclude, the conversion of biomass to methane and hydrogen can be obtained via plasma technology from the biomass. Also, it shows plasma technology as an alternative fuel source. The presence of Tar formation should be considered to maintain the quality of the gas produced in the plasma gasification. Some scholars have performed degradation of dyes via plasma technologies and it shows a promising result (Jiang et al., 2012; Lukes et al., 2012; Reddy et al., 2013; Medel et al., 2012; Chandana et al., 2015; Bandose et al., 2017; Zhou et al., 2021a) . Zhou et al. (2021a) investigated the degradation of mixture organic pollutants using the micro-plasma bubble, and dye products were analyzed by High-Performance Liquid Chromatography (HPLC) coupled with a mass spectrometry analyzer. The selections of dye combinations are azo, dye mixture (AY and Orng-II), azo, and cationic dye (AY and MB), and combinations of all dyes (AY, Orng-II, and MB). A micro-plasma bubble column reactor consists of an electrical circuit measurement, optical emission spectroscopy (OES), and liquid chromatography (LC-MS system). The power supply of the system was provided from Leap 100, (PlasmaLeap Technologies, Australia). Moreover, this power supply provides the high voltage output, ranging from 0 to 80 kV with frequency 100 -3000 Hz generate plasma discharges. Plasma bubble column reactor, the part of the system, consists of a 5 mm-thick stainless-steel rod (acting as the HV electrodes), an inner and outer diameter of 5.0 and 8.0 mm, respectively, and a 12 mm-inner-diameter outer dielectric tube. Plasma treatment was controlled from 1 to 10 min, and discharge peak voltages were controlled at 10.4 kV, 11.6 kV, 12.4 kV, 13.6 kV, 14.4 kV, respectively, and frequencies were maintained at 500 Hz, 750 Hz, 1000 Hz, 1250 Hz, (Huang et al., 2016) . R.C. Sanito et al. and 1500 Hz, respectively. Air flow rate was controlled at 2.0 standard liters per minute (SLM) to generate the plasma discharges. The results showed that degradation of azo dye AY could be obtained by 99.99% in 10 min, at 14.4 kV of voltage. The kinetic constant was confirmed at 0.413 min -1 . Fig. 6a, Fig. 6b, and Fig. 6c give the information on the degradation pathway of azo dye, orng-II, and methylene blue (MB). Bansode et al. (2017) stated that higher discharge voltage generates high plasma densities and reactive species indicating similar degradation trends in the Orng-II and MB dyes in the Microbubble Plasma Systems. A setting of higher frequency at 1500 Hz confirmed a high kinetic constant of 1.585 min -1 (Methylene Blue), 1.1263 min -1 (Orng-II) and 0.548 min -1 (Azo Dye AY). Also, alkaline conditions support the degradation of dye in the systems due to generated H 2 O 2 , •OH, and •O 2 − that plays an important role as strong oxidation to degrade pollutants⋅H 2 O 2 is generated from the interaction of energetic electrons and water molecules. Furthermore, O 3 molecules are generated from plasma bubbles contact with water, combining with the H 2 O 2 to generate the O 2 and •OH. During the treatment of mixed dye pollutants, namely, azo dye mixed with methylene blue, azo dye mixed with Orng-II, and azo dye combined with Orng-II and methylene blue, removal of TOC can be obtained by 92.2%, 88.5%, and 81.9%, respectively, in 20 min. It confirms that reactive plasma bubbles play an integral role in dye degradation (Fig. 7) . The reaction of reactive species can be described as follow: Another study by Chandana et al. (2015) confirmed that atmospheric-pressure non-thermal plasma jet indicated a promising result on the degradation of methylene blue pollutants. The establishment of H 2 O 2 is recognized to play a major role in the elimination of dyes. Plasma jet was maintained by applying a potential difference of electrodes from 16 to 20 kV at 50 Hz, and power variation was set up between 2 W and 5 W. Excited plasma species and water molecules play a major role in establishing H 2 O 2 formation and increase the function of time. After that, H 2 O 2 may be converted to hydroxyl radicals due to the reaction with UV light. Formation of reaction can be seen as follow: •OH + •OH → H 2 O 2 (45) pH plays a significant role in establishing the formation of various ionic species. In the presence of zero air and nitrogen bubbling, excited nitrogen plays a major role during the association to form NO and NO 2 that convert it to NHO 3 and HNO 2 . Furthermore, there is an excitation of oxygen and nitrogen molecules that transformed it to NO, NO 2 molecules, and inorganic acid. In more precise, the concentration of excited species formed and transformation of mineral acids occurs, and there was an establishment of acid proton in an argon plasma discharge because of H 2 O* molecules and acidic proton may be generated from argon metastable species Ar (3p) that provide energy transfer (Medel et al., 2012) . Moreover, acid-base dissociation is recognized as chemical species in water and gas-liquid environments (Lukes et al., 2012) . Degradation of methylene blue can be obtained by 99% in 40 min using argon plasma jet compared to nitrogen and air. In addition, argon plasma jet indicated a better result in removing methylene blue with values of 99%, 97%, and 96% from initial concentration 30 ppm, 40 ppm, and 50 ppm, respectively. Also, higher reactive species may be generated from the process that become the main contribution of dye degradation. The reactions can be described as follows: •OH + NO /NO 2 → HNO 2 / HNO 3 (52) In addition, Garcia et al. (2017) treated methylene blue in an aqueous solution using a non-thermal microwave plasma jet at an atmospheric-pressure. Argon was used as a carrier gas, and microwave power was set up at 200 W. Quartz tube was used with value of 1.5 and 4 mm of inner and outer diameter, and the flow rate range from 350 to 1400 sccm. Concentrations of methylene blue were ranging from 5 to 250 mg/L and at the temperature 55 • C. Long-lived excited neutrals creates reactive species from the thermal energy in microwave plasma jet that containing of N 2 , NO, and O. Furthermore, metastable argon atoms from penning reactions generates argon atoms, argon ions (Ar + ), R.C. Sanito et al. and argon dimmer ions Ar 2 + throughout Ar m ionization collision, and metastable associative ionization with the recombination reactions of ions Ar + , and Ar 2 + produce argon excited atoms (Ar*), and combination of H 2 O 2 species, charged particles, ozone, hydrogen peroxide, and UV radiation, causes further dissociation and produce OH aq. Lastly, OH reactive species in water react due to the presence of a third molecule to generate hydrogen peroxide. Then, diffuse to the bulk liquid (Garcia et al., 2010) . Ar m ionization collisions can be described as: Ar m + Ar m → Ar + + Ar + e - Ar m + Ar m → Ar 2 + + e - Ar + e -+ e -→ Ar* + e - Ar + e -+ Ar → Ar* + Ar Ar 2 + + e -→ Ar* + Ar (2011) investigated whether dielectric barrier discharges (DBD) combined with advanced oxidation processes (AOPs) can be used on decolorization of reactive textile dyes, namely, reactive black 5. Some catalysts such as H 2 O 2 , Fe 2+ and Cu 2+ were used. Energy densities were controlled at 45 -315 kJ/L, and plasma treatment was performed at 24 h. An effective result of reactive black 5 decolorization can be obtained by 97% with the addition of 10 mM H 2 O 2 . The best performance on the degradation of reactive black 5 can be obtained with a decrease in the dosage of H 2 O 2 that may prevent the consumption of •OH radicals and increase the decolorization. Then, degradation efficiency and decolorization reaction can be shown as follows: To conclude, atmospheric-plasma bubble, non-thermal plasma jet and dielectric barrier discharges show a good result on decolorization of contaminants in the aqueous solution, confirming a promising result on the degradation of dyes. Many scholars have conducted studies looking at degradation of organic compounds and it shows a promising result (Qu et al., 2013; Markovic et al., 2015; Dobrin et al., 2013; Wardenier et al., 2019) . Wardenier et al. (2019) used pulsed dielectric barrier discharge to remove pesticides atrazine (ATZ), alachlor (ALA), dichlorvos (DVOS), diuron (DIU), pentachlorophenol (PCP), and pharmaceuticals carbamazepine (CBZ), 1.7-α-ethinylestradiol (EE2) and plasticizer bisphenol A (BPA). Plasma discharged was generated by air, argon, or oxygen, and it was continuously flown through the reactor. 50 kHz of frequency was applied in the reactor cell, and discharge was produced in a pulsed mode with 15%. During the experiment, 2.5 L of synthetic water solution was fed to the reactor at flow rates of 56.3 mL min -1 , and 60 mL, respectively. Samples were collected at the regular time intervals, namely, 2.5 min, 5 min, 10 min, 15 min, 20 min, 25 min, and 30 min, respectively. The efficiency removals of ATZ, ALA, DIU, PCP, DVOS, BPA, CBZ, and EE2 were 56.9%, 57.8%, 62.4%, 69.3%, 70.2%, 76.7%, 82.4% and 87.8%, respectively. The decomposition of complex pollutants is related to the role of oxidative species such as hydroxyl radicals (•HO), nitrogen oxide (•NO), atomic oxygen (•O), ozone (O 3 ), and hydrogen peroxide (H 2 O 2 ). NO plays a major role in fast ozone quenching that leading to nitrogen oxide (NO 2 ). The formation of reaction can be described as follows: N + e -→ 2N* + e - N + e -→ 2O* + e -(70) Another study by Dobrin et al., (2013) found that pulsed corona discharged showed a promising result on the degradation of pharmaceutical drug diclofenac (DCF). Oxygen was used as carrier gas with flow rate 1 L/min. Discharged of the gap was controlled at 3.5 mm. An amplitude of the voltage was controlled at 18 kV, and the voltage was maintained at 2 kV. Time of plasma was controlled under 2,5,7 and 10 min. Final concentration of DCF was obtained less than 5 mg/K after the treatment. In 5 min, approximately 70% of DCF can be degraded properly, and only 50% of chlorine remained in the residue as the organic form. pH of DCF solution decreased from 7 to 5.3 in 15 min. The most striking finding was the removal of 200 mg/L DCF in 30 min of ozonation. After that, Clremained in the aqueous solution and formed the by-product associated with the attack of hydroxyl radical. Fig. 8a shows the degradation of diclofenac. Furthermore, the application of a non-thermal plasma reactor with dielectric barrier discharged and combined with Fenton reaction to destroy ibuprofen from aqueous solution was investigated by Markovic et al. (2015) . Ibuprofen is categorized as a pharmaceutical compound that mostly contaminated surface and groundwater. Three experimental systems are installed for degrading the Ibuprofen, namely, dielectric barrier discharge reactor (DBD), DBD combined with Fe 2+ , and Fenton treatment were generated by hydrogen peroxide and iron salt. The solution of Ibuprofren was prepared via the double distillated water with the concentration 60 mg/L. The DBD/Fe 2+ preparation was performed with the addition of the catalyst of Fe 2+ , with the concentration at 5 mg/L. Furthermore, for preparing the Fe 2+/ H 2 O 2 solution, concentrations of Ibuprofen, Fe 2+ , and H 2 O 2 were 60 mg/L, 25.2 mg/L, and 306 mg/L, respectively. 17 kV of high voltage and 300 Hz of frequency were applied to the outer electrode. Moreover, filamentary barrier discharged was generated with 3 mm gap between inner metal electrode and glass tube. Degradation of ibuprofen can be obtained by 85% (DBD) and 99% (DBD/Fe 2+ ). In the 10 min, the DBD/Fe 2+ had 30% higher efficiency removal degradation than others. In 12 min, the percentage degradation between treatments decreased to 20%, and after 15 min, the treatment was less than 20%. Thus, the homogenous catalyst significantly affected the efficiency degradation of Ibuprofen in non-thermal plasma reactor. Degradation efficiency can be obtained by 78%, and it remains at 85%. Catalyst creates the reaction of •OH radicals, and it can be explained as follow: Fenton reaction plays a significant role in the degradation of products such as four aromatics products and two aliphatic products. OH• radicals play a significant role as an oxidative species for the ibuprofen oxidation and oxidation of hydrogen peroxide. In addition, the Fenton reduce the total organic carbon (TOC) value by 15%. Also, the TOC value can be reduced by 35% with the catalytic NTP (DBD/Fe 2+ ). The measurement of TOC represents the oxidation of molecules to the smaller organic pollutants (Zhou et al., 2021a) . Hydrogen peroxide inside the reactor plays a major role in the degradation of Ibuprofen, and all the catalyst may enhance the oxidizing power through the Fenton (Photo-Fenton) reaction. Unfortunately, water from the treatment should be neutralized from the post-treatment. An illustration of the degradation pathway of Ibuprofen is outlined in Fig. 8 . Qu et al. (2013) researched the removal of phenol from water solution using corona pulsed discharged combined with activated carbon (PCDP/GAC). 1.0 g GAC was filled in wastewater in the high voltage multi-need electrode and ground plate electrode. The volume of wastewater is 250 mL, and the circulating rate of wastewater was controlled at 100 mL/min. Gas flow rate and electricity power were controlled at 6 L/min and 23.6 kV, respectively. Removal efficiencies of Cd 2+ and phenol were obtained at 69% and 87.3%, respectively, in 60 min during the treatment from PCDP/GAC. Furthermore, increasing the pulsed voltage and feeding gas significantly reduces phenol and Cd 2+ during the treatment. OH radicals, H 2 O 2 , and O 3 degrade phenol through the hydroxylated intermediates and organic acids. Reactive species react with phenol, forming decomposition products, namely, hydroxylated and nitrated aromatic ring molecules (Banaschik et al., 2017) . Also, a chemical exchange between Cd 2+ and surface oxygen groups that play an integral role in Cd 2+ extraction responsible for generating intermediate oxygen and byproduct from a PCDP improves the adsorption of Cd 2+ on GAC. Moreover, the Fourier transform infrared spectroscopy analysis indicates that O − H, = C − H, and C = C bonds are cleaved, and Ar − O − C and C = O groups increased during the treatment. Unfortunately, the appears of peaks do not represent the original GAC. This confirms that phenol is transformed to benzoquinone or small organic compounds, for example, carboxylic acid, aldehyde, and ester. In conclusion, plasma technology systems can be modified to degrade organic compounds combined with Fenton and activated Markovic et al. (2013) ). carbon to deal with harmful pollutants. OH radicals generated from plasma play a major role to degrade the contaminants. Treatment of toxic gases, namely, volatile organic compounds (VOCs) and PCDD/Fs in plasma technology shows promising results by some scholars (Vandenbroucke et al., 2011; Lu et al., 2012; Mao et al., 2018; Li et al., 2021) (Table S1 ). Mao et al. (2018) used dielectric barrier discharged (DBD) to eliminate benzene. The total gas flow rate was controlled at 300 mL/min, and purity of He was 99.99%. An electric furnace was used to control the temperature at 500 • C. A power supply includes a high voltage probe, a pulse power supply, and a digital phosphor oscilloscope were used in the unit. Decomposition of benzene can be obtained because of the CeO 2 addition and the presence of O 3 . Furthermore, Ce 3+ can be oxidized to the Ce 4+ that generates O* species that enhance decomposition of benzene. Lu et al. (2012) used a rotating gliding arc discharge reactor for degrading toluene. The gas flow rate was controlled at 5.4-10.8 m 3 h -1 . A discharged power was controlled at the range 6-10 kV with an autotransformer. The results indicated that removal efficiency can be obtained maximum of 77% from the initial concentration 200 mg m -3 . In addition, the combination of water vapor and gas mixture play a major role in the decomposition of toluene because of the presence of some reactive species, such as electrons, positive and negative ions, and free radicals. Li and collaborators found that the combination of dielectric barrier discharges and photocatalyst (Ag-TiO 2 /γ-Al 2 O 3 ) could remove the toluene with the percentage of 81% CO 2 . In fact, the radicals, namely, the O 3 and OH radicals (Vandenbroucke et al., 2011) , and electron hole pairs, such as H + and e -from the photocatalyst, create a reaction for degrading toluene and its intermediate products. Thereby, degradation of toluene can be obtained from the gliding arc discharge. Mizeraczyk et al. (2005) investigated the using the atmospheric-pressure microwave discharge for treating the hazardous gas that consists of volatile organic compounds (VOCs) combined with nitrogen gas and the microwave power ranging from 200 to 400 watt under 10% of gaseous concentration. This result confirmed that the VOCs may be degraded fully with the relatively low-cost energy, where the energy calculation was 1000 g (kW-h) − 1 . This study also confirmed that volatile organic compound (VOCs) and VOC(s) reforming may be transformed to hydrogen. Also, the corresponding energy of the mass yield can be obtained from the waveguide-supplied MS. Thereby, an atmospheric-pressure microwave plasma reactor shows a promising result on the treatment of gaseous pollutants. Yan et al. (2007) used gliding arc discharges to degrade PCDD/Fs. The dry air was set up at 300 mL/min, and power frequency was controlled at 50 Hz. Then, the reactor was run with 10 kV of the voltage, and the length of electrode was 150 mm. The total concentration reduction ranged from 25% to 79%, and the TEQ value was 61%. Electron collision occurs that provides broad energy from the broad energy distribution consisting of O 2 , N 2 , and H 2 O (Fig. 9) . Thereby, energy transfer occurs, causes excitation, ionization and dissociation. To conclude, Dielectric barrier discharge gives a promising result on degrading the VOC and PCDD/Fs from air pollution. The setting of parameters helps to give the proper parameters that generate some reactive species that responsible for crushing the pollutants during the operation. Plasma technology shows a promising result on the deactivation of bacteria from different fields of studies (Kim et al., 2013; Laurita et al., 2015; Liao et al., 2017; Cubas et al., 2019 Cubas et al., , 2021 . Perez et al., (2019) used cold atmospheric plasma (CAP) for killing Xanthomonas vesicatoria (XV) strain IPV-BO 2684. To generate the plasma activated water (PAW), CAP was combined with a DBD reactor consisting of a polystyrene cylindrical case. The plasma source was supported by the HV generator to generate pulses with a slow rate of kV/ns and 50 mJ energy per pulse. The system was controlled for 10 min with the source of peak voltage at 20 kV and the frequency of I kHz. Then, the air gap was maintained at 1 mm for in vitro and in planta experiments (1-3 h). As a result, the plasma activated water can be generated containing of hydrogen peroxides (H 2 O 2 ), nitrates (NO 3 -), and nitrites (NO 2 -). These PAW were analyzed using the Amplex Hydrogen Peroxide Assay Kit. The results showed that PAW affect antimicrobial activity in in vitro experiments. In a plant experiment on the bacterial leaf spot of tomato showed a lower infection rate percentage of relative protection (RP) at values of 61% and 51%, respectively. OH radicals can be generated from the cold atmospheric pressure plasma containing heavy particles (positive and negative ions, atoms, free radicals and excited or non-excited molecules), electrons, and UV-rays. Sanito et al. (2021b) stated that the presence of OH radical shows a promising result in killing the bacteria because of this reactive species prevented the transcription of deoxyribonucleic acid (DNA) and penetrated the membrane cells. Chemical radicals play an integral role for the oxidation of the cell membrane of organism via the lipid peroxidation and reducing the ozone (Cubas et al., 2019) . Thereby, microorganism can be killed during the process. Butscher et al., (2016) investigated the plasma inactivation of microorganisms on sprout seeds of onion (Allium cepa), radis (Raphanus sativus), cress (Lepidium sativum), and alifalfa (Medicago sative) in a dielectric barrier discharge (DBD). Two parallel aluminum electrodes with the size 100 mm x 200 mm covered by dielectric barriers from polymethylmethacrylate or polycarbonate with a thickness 2 mm and a 5 mm gas gap. Argon is used as a working gas with 5.6 nlm. The pulses were controlled at 2.5-10 kHz, 6-10 kV, and 500 ns. The results show that the maximum inactivation of E. coli was 2.47 log. A reactive oxygen species from plasma contributes to the inactivation of microorganisms that related to the improvement of the plasma power density. Machala et al. (2013) stated that chemical and bactericidal effects are associated with the formation of ROS (reactive oxygen species) and RNS (reactive nitrogen species) in bio-decontamination. RNS is well known as the active agent in the virus inactivation and causes disruption of multiple cellular organelles (Auten and Davis, 2009 ). Moreover, plasma gas provides a strong bactericidal efficacy with O 2 or air admixtures (Nayak et al., 2017) . Thereby, gas has an effect for creating the reactive species. Stoffles et al., (2008) stated that energetic electrons from reactive chemistry are associated with the formation of free radicals and photon-emitting excited species. This statement is supported by the opinion of Zhu et al. (2009) that metastable He atoms play an integral role in generating N 2 + through a penning ionization. Also. argon gas mix with air in non-thermal plasma indicates the oxidizing species in the gas/liquid interface, namely, RNS, ROS, H 2 O/H 2 O 2 , and ozone responsible for crushing the membrane and cytoplasm of bacteria (Fig. 10a) . In addition, chemical species derived from the air plasma indicates a better result compared to the chemical species from Ar plasma (Cubas et al., 2021) . Then, the upper electrode of the gas phase that discharges close to the water surface indicates the high damage of bacteria, followed by reactive species' attack (Estifaee, 2019) . Thus, the inactivation of bacteria can be obtained by plasma technology. Furthermore, Lukes et al. (2014) stated that the formation of transient species of OH, NO 2 , NO radicals, and long-lived chemical products, for example, O 3 , H 2 O 2 , NO 3 -, NO 2 generated by plasma discharged at the liquid interface. These species related to the chemical and biocidal effects that play a significant role in the degradation of bacteria are evaluated using E. coli. pH value of the plasma-treated solution is controlled using a phosphate buffer at pH 3.3, 6.9, or 10.1. The mixtures of oxygen with nitrogen or argon gases were used during the treatment. Experiment with E. coli shows that inactivation depends on the gas phase plasma and pH, similar to inactivation with PAW. Moreover, the concentration of NO 2 and H 2 O 2 associated directly with peroxynitrite may be formed in the PAW, confirming the bacterial inactivation. NO from the residue is generated by different isoforms of nitric oxide synthase (NOS) and (ROS) by NADPH oxidase (NOX) that responsible for inhibition of adenoviral replication. It is clearly can be understood that reactive species from plasma treatment reliable in killing bacteria. To summarize, the inactivation of bacteria depends on the reactive species radicals generated from the plasma system. The carrier gases (mixing and non-mixing with air), power supply set-up provide the diversity of reactive species to kill bacteria in an aqueous solution. Some studies have confirmed that plasma technology shows a promising result to eliminate the virus, for instance, spring viremia carp virus (SVCV) model, adenovirus and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (Zimmerman et al., 2011; Chen et al., 2020; Filipic et al., 2020; Guo et al., 2020; Moldgy et al., 2020; Song et al., 2022) . Song and colleagues (Song et al., 2022 ) applied a pulsed corona discharged plasma (PCDCP). The voltage and frequency were controlled between 0 and 30 kV and 0-200 Hz, respectively. The gas flow rates were maintained at 6 L/min -1 . Furthermore, the peristaltic pump was controlled at 100 rpm. During the study, 5 mL of virus suspension were used as the model. Each sample were collected at 15, 30, 60, 90, 120, 180, 240 , and 300 s, respectively, and the control (sample with the absence of virus) were also prepared. The 4-log 10 reduction of SVCV can be obtained by 120 s of treatment. In more precise, the higher reductions of virus inactivation can be obtained with the frequencies of 70 Hz and 80 Hz. Moreover, the input power controlled at 0.024 kW (19.0 kV) reduced the titer more than 0.018 kW (16.8 kV) and 0.010 kW (14.3 kV), where virus titer was detected below the detection limit in 180 s of exposure time (4-log 10 ) reduction⋅H 2 O 2 and O 3 play an integral role on the degradation SVCV after 60 s. Furthermore, •OH radical and 1 O 2 increases after the treatment for 60 and 30 s, respectively. It can be assumed that reactive species reacts with the viral proteins and genome causes the virus inactivation, especially the 1 O 2 (Cho et al., 2010) . In addition, O 3 and H 2 O 2 play an important role for the viral inactivation (Wolf et al., 2018; Su et al., 2018) . This confirmed that reactive species oxidizing the protein, damages the structure and function of genome. Thereby, it causes the virus inactivation or deterioration of viral infectivity (Ersoya et al., 2019; Guo et al., 2018) . Zimmerman et al. (2011) investigated an effect of cold atmospheric plasma (CAP) in an adenovirus solution. The plasma device in this study consists of a UV emission spectrum. This UV power density was set up in length 170-340 nm wavelength. Furthermore, the measurement density was controlled by 12 mm. Ambient temperature was controlled at 20 • C and humidity was controlled at 40%. This device has one surface micro discharge (SMD) plasma electrode (10×10 cm 2 ) with an insulator plate (10 mm thick). The diameter of the grid was 0.5 mm. Plasma is generated from the mesh grid side with a high sinusoidal ac voltage with a value of 4.7 kV pp at 10 kHz between the metal plate and mesh grid. Furthermore, the power consumption of the electrode was controlled at 0.5 W cm -2 . HEK293 cells with E1 region of adenovirus were used in the experiment. The mouse fibrosarcoma cell line CMS-5 was infected with adenovirus at a density of 5 × 10 5 cells. The application of CAP indicates inhibition of virus with 100% of survival of cells, and it shows inhibition of virus replication because the use of CAP protects the lysis of cells from the infection of the virus. Moreover, inactivation of adenovirus ranging from 7.5 × 10 2 PFU mL -1 . NO with its intermediates of NO radicals, NO -, NO + , N 2 O 3 , N 2 O 4 , ONOO -, and ROS (O -2 , H 2 O 2 ) are presumed responsible for attacking the virus, where these reactive species have an integral role as antimicrobial and antiviral. Mohamed et al. (2021) confirmed that there are specific reactive species responsible for dealing with the inactivation of virus that causes the viral pathogen, such as, O 3 , O 2 , and H 2 O 2 . The presence of O 3 and NO 2 usually generates the production of N 2 O 5 that transform it to peroxynitrate (ONOO ̶ / ONOOH) on the layer of water (Guo et al., 2020; Mohamed et al., 2021) that responsible for dealing with the virus inactivation. The presence of peroxynitrate, therefore, conclude that it is the most crucial point for the inactivation of the virus. Another study conducting a cold atmospheric plasma reactor for inactivation of the virus has been performed by Aboubakr et al. (2016) . A radio-frequency (RF) atmospheric plasma jet is applied with an ignited argon (1% admixture of molecular gas) and a 1.9 mm quartz tube during the study. The flow of gas was set at 1.5 standard liters per minute (SLM). Moreover, RF power frequency and power of jet were controlled at 20 kHz and 2.5 W, respectively. Four types of gas mixtures were used during the study, namely, Ar, Ar +1% O 2 , Ar +1% air, and Ar +0.27% H 2 O. The specific scavengers were used to evaluate plasma product activity. Feline calici virus strain 255 was chosen as a model for treatment. In the study, the combination of Ar +0.27% H 2 O showed a high concentration of H 2 O 2 with a value of 4790 μM after 2 min of plasma exposure. The addition of H 2 O 2 and •NO 2 is a dominant reactive species for virus inactivation. In addition, pH reduction shows that O 3 and NO 2 contribute significantly to virus inactivation related to the various gas mixtures. A scavenger experiment indicates that oxygen plays an integral role in the deactivation of the virus with Ar +1% O 2 plasma. Increasing humidity in an argon plasma improves the number of H 2 O 2 and •OH (Fig. 10b) . Thereby, this confirms that plasma is a useful tool for virus inactivation. Xia et al. (2019) studied the inactivation of airborne viruses by a packed bed non-thermal plasma reactor. For example, one or two AC voltage amplifiers power dielectric barrier discharge (DBD) reactor, variable 0-20 kV high voltage amplifier, and a 30 kV neon transformer. There is a significant increase of virus with the value of more than 2.3 log infective MS2 (2 log inactivation). 90% (1 log) inactivation of airborne MS2 can be achieved with an ozone dose with a value of 1.28 min mg m -3 from reactive oxygen species. Thus, the inactivation of the virus can be obtained via the treatment of DBD. Since the outbreak of the SARS-CoV-2 in 2019, the infection via the aerosol and water has become a serious issue because of the transmission over 30 m in an atmospheric condition (Gorbunov 2020) . Furthermore, their Virions exists on the surface of plastic, metals, and cardboard for some hours. Thus, some scholars have developed an investigation on the performance of cold plasma to deal with the SARS-CoV-2 (Bisag et al., 2020; Chen et al., 2020) . Bisag et al. (2020) used a parallel-plate direct DBD configuration consisting of aluminum electrodes (5 × 150 × 2 mm) supported and covered by two dielectric supports, with the electrode gap of 2 mm. The device was set up by a micro-pulsed high voltage generator (AlmaPULSE; AlmaPlasma) for generating 56 kV of peak-to-peak voltage and the 14 kHz of frequency with the flow rate 0.6 slpm. The nebulizer was loaded with the 5 mL SARS-CoV-2 RNA, where the aerosol was collected with 1 mL distilled water. The degradation of SARS-CoV-2 RNA is shown in Fig. 10c . The result showed that CAP-treated with the RNA suspensions indicated a negative result based on the RNA suspension compared to the untreated sample with positive results. The performance of CAP inactivation on SARS-CoV-2 was also assessed by Chen et al. (2020) . Ar and He gases were controlled at 6.4 L/min and 16.5 L/min, respectively, at 16.8 kV and 16.6 kV. The reactive species was measured using optical emission spectroscopy. The SARS-CoV-2 samples were obtained from the swab test from the patient with respiratory illness. Various material surfaces were treated using the SARS-CoV-2 at the 2×10 5 PFU in 25 µl of volume. After that, the surface of the material was exposed with the argon and helium gases. As a result, CAP inactivated the SARS-CoV-2 less than 180 s of treatment. From the surface of metal, there was a decontamination of the 30 s from the exposure study. The plastic and leather ball surface was deactivated in 30 s and 60 s. The striking findings of this study were the surface inactivation of SARS-CoV-2 using a CAP related to composition, roughness, and absorptivity. Moreover, the higher discharge intensity generates more reactive species. As a result, the highest inactivation efficiency of the virus on the metal surface can be obtained from the study. To conclude, CAP shows a promising result on the virus's deactivation since reactive species generated from the plasma discharged. Furthermore, for further application to the inactivation of SARS-CoV-2 that attach to the surface of the material, such as composition, roughness, and absorptivity, the higher discharged of CAP is thus recommended in the treatment of SARS-CoV-2. Some researchers have investigated the deactivation of fungi using plasma technology for different aspects, namely, health and agriculture (Zhang et al., 2014; Borges et al., 2017; Borges et al., 2018; Misra et al., 2019; Los et al., 2020) . Borges et al. (2017) investigated the use of cold atmospheric pressure jet to deal with Candida albicans. 99.5% purity He was used as the carrier gas. The gas flow rate was controlled at 2 SLM. Moreover, discharge power was controlled at 1.8 W. Nozzle and sample surface were maintained at 1.5 cm in all experiments. The results indicated that fungal reduction can be obtained more than 1-log reduction during viable cell count after 90 s exposure. According to Liebmann et al. (2011) , destruction of cells occurs because of the presence of reactive species, namely, nitric oxide, nitrogen oxide, hydroxyl radical, superoxide ozone, and singlet ozone (Fig. 10d) . Borges et al. (2018) confirmed an effect of cold atmospheric pressure plasma jet for treating the oral candidiasis. 99.5% purity helium was used as the carrier gas with a constant flow 2 SLM is controlled by a mass flow controller. The reactor nozzle was connected to a 1-m-long, 2.5-mm-diam polyurethane tube. The plasma jet device was controlled by a Miniplus4 AC power supply that generates an AC voltage signal with an amplitude up to 20 kV. The frequency was set up at 40 and 40 kHz. C. albicans ATCC 18804 cells were grown in a Sabouraud dextrose agar at 37 • C. After that, C albicans ATCC18804 suspension with a value of 1×10 8 cells mL -1 was contacted with the mice tongue for 3 min. The results showed that plasma jet may reduce the infection of C. albicans since there is a significant difference in the number of invading hyphae. Modification of plasma treatment or protocols significantly impacts the production of reactive species to fungal cell. Modifying amplitude modulation and reducing power play an integral role in generating reactive species from atmospheric-cold plasma. In addition, Zhang et al. (2014) tested an effect of an atmospheric-pressure cold plasma on fungus-infected plant leaves (P. erubescens). Leaves of P. erubescens infected with plant pathogens was treated by needle-shaped plasma jet during different treatment time. Infection was showed with the presence of black spots on the leaves. Based on the study, deterioration of leaves can occur during the treatment on 30 s. Longer duration caused the damage of the leaf blade and leaf vein in 40 s during the treatment because of the plasma activated-species. As a consequence, the weak leaf veins were responsible for the deterioration of P. erubescens. There was a decrease of black spots on leaves during the plasma treatment time, confirming a good degradation of fungi from the atmospheric-pressure cold plasma jet. During the treatment, the number of black spots with a diameter < 2 mm rapidly decreased with the treatment time, emphasizing that small black spots were relatively easier to heal by the plasma jet. Conversely, larger diameters, which the value > 5 mm, were more difficult to be eliminated by atmospheric-pressure plasma jet. The inhibition mechanism is dominated by excited helium (He*), N 2 (C → B), OH, O, and Hα (Stoffels et al., 2008) . To conclude, plasma technology shows a promising result on degrading fungi in different fields, such as health and agriculture. Thus, plasma technology is thus suggested in the elimination of fungi for the control the fungi. Plasma technology has the excellent opportunity to be implemented in the real application and many specific fields, not only to deal with the hazardous waste and wastewater but also for the conversion of biomass and inactivation of microorganisms (bacteria, fungi, and virus). Some plasma technologies have been applied to treat pollutants, for instance, STARTECH (plasma electric waste converter), PACT (Plasma Arc Centrifugal Treatment), PLASCON (In Flight-Plasma Arc System) (Rahuman et al., 2000; Zinovlev et al., 2007) , direct current plasma power supply and plasma furnace stations (Tetronics, 2015) and high-temperature plasma torch (APEXGREEN, 2021) . The goals of the system are to treat hazardous waste and resource recovery. However, there is no information on the treatment of SARS-CoV-2. Focuses on the virus, since the outbreak of the coronavirus 2 (SARS-CoV-2) pandemics worldwide, it has many challenges to the societies. Especially, the transmission via the aerosol should be concerned seriously (Bayarri et al., 2021) . As the information of the treatment of SARS-CoV-2 is described in this paper from many literatures, plasma technology shows a promising result to deal with virus and give many strategies for preventing the virus transmission via the aerosol that causes the transmission of the virus, including SARS-CoV-2 virus (Zimmerman et al., 2011; Guo et al., 2020; Bisag et al., 2020; Chen et al., 2020; Mohamed et al., 2021) . Thus, the development of plasma technology to inactivate the SARS-CoV-2 from the aerosol should be further investigated during the pandemic situation. On the basis of the aforementioned discussion in this review paper, there are some important conclusions that can be obtained. Plasma technology with different systems can be considered to degrade pollutants and microorganisms because of the presence of reactive species generated in the plasma discharged. In this aspects, reaction oxygen species (ROS), reactive nitrogen species (RNS), and OH radicals in the plasma discharges play an important role to degrade the contaminants such as metals, metalloids, VOCs, dyes, and microorganisms (bacteria, fungi and virus), depends on the setup of parameters from the plasma systems. Combination of plasma technology with other process such as the photocatalyst, fenton and activated carbon are suggested to improve the degradation of difficult organic compounds from the aqueous solutions. Also, the formation of methane and hydrogen can be obtained from the degradation of biomass via plasma technology. The addition of flux agents and a combination of the photocatalyst in the plasma systems shows a promising result on degrading metals and VOCs. The scavenger test of electron holes combined with the photocatalyst gives the information of the electron holes. Furthermore, the plasma system also indicates a promising result on the inactivation of bacteria, fungi and virus. Further development should be focused on the economic analysis for the large-scale treatment in the various application that dealing with recent issues related to hazardous waste treatment, biomass conversion and preventing the transmission of SARS-CoV-2 virus. In addition, the research focusing on the treatment of the SARS-CoV-2 virus via plasma technology will become an interesting topic for studying the pandemic issues. Therefore, these research topics should be considered in nearby the future. The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. Inactivation of virus in solution by cold atmospheric pressure plasma: identification of chemical inactivation pathways Ding Jian Green Energy Technology Company Limited Oxygen toxicity and reactive oxygen species: the devil is in the details Fenton chemistry promoted by sub-microsecond pulsed corona plasmas for organic micropollutant degradation in water Effective degradation of organic water pollutants by atmospheric non-thermal plasma torch and analysis of degradation process Biomass gasification and Pyrolysis Can ozone inactivate SARS-CoV-2? A review of mechanisms and performance on viruses Synthesis of microand nanomaterials in CO 2 and CO dielectric barrier discharges Cold atmospheric plasma inactivation of aerosolized microdroplets containing bacteria and purified SARS-CoV-2 RNA to contrast airborne indoor transmission Amplitude-modulated cold atmospheric pressure plasma jet for treatment of oral candidiasis: In vivo study Cold atmospheric pressure plasma jet modulates Candida albicans virulence traits Plasma inactivation of microorganisms on sprout seeds in a dielectric barrier discharge Atmospheric pressure nonthermal plasma jet for the degradation of methylene blue in aqueous medium Thermal plasma solid waste and water treatments: a critical review Glow Discharge Processing: Sputtering and Plasma Etching Catalytic effects of eight inorganic additives on pyrolysis of pine wood sawdust by microwave heating Cold atmospheric plasma for SARS-CoV-2 inactivation Visible light sensitized inactivation of MS-2 bacteriophage by a cationic amine functionalized C60 derivative Removal of VOCs from gas streams via plasma and catalysis. Catalysis Reviews. Taylor & Francis. Cold atmospheric plasma for SARS-CoV-2 inactivation Influence of non-thermal plasma reactor geometry and plasma gas on the inactivation of Eschericia coli in water Inertization of heavy metals present in galvanic sludge by DC thermal plasma Final treatment of spent batteries by thermal plasma Application of thermal plasma for inertization of sludge produced during treatment of landfill leacheate Effect of chemical species generated by different gemoetries of air and argon non-thermal plasma reactors on bacteria inactivation in water Degradation of diclofenac in water using a pulsed corona discharged Decolorization of reactive textile dyes using water falling film dielectric barrier discharge Decomposition of volatile organic compounds using corona discharge plasma technology Plasma purification of halogen volatile organic compounds Mechanisms of the Escherichia coli and Enterococcus faecalis inactivation by ozone Mechanism of E. coli 905 inactivation by direct-in-liquid electrical discharge plasma in low conductivity 906 solutions Cold plasma, a new hope in the field of virus inactivation Plasma Chemistry Plasma Physics and Engineering Gliding arc gas discharge Excitation of species in an expanded argon microwave plasma at atmospheric pressure Microwave atmospheric pressure plasma jets for wastewater treatment: degradation of methylene blue as a model dye Thermal plasma technology for the treatment of wastes: a critical review Aerosol particles generated by coughing and sneezing of a SARS-CoV-2 (COVID-19) host travel over 30 m distance Mechanism of virus inactivation by cold atmospheric-pressure plasma and plasma -activated water Plasma activated water: an alternative disinfectant for S protein inactivation to prevent SARS-CoV-2 infection Superoxide ion: generation and chemical implications Thermal plasma waste treatment Atmospheric plasma generates oxygen atoms as oxidizing species in aqueous solutions Plasma aided gasification of biomass and plastics using CO 2 as oxidizer. International symposium on non-thermal/thermal plasma pollution control technology & sustainable energy Reaction pathways of hemicellulose and mechanism of biomass pyrolysis in hydrogen plasma: a density functional theory study Degradation of acid orange 7 azo dye in aqueous solution by a catalytic-assisted, non-thermal plasma process Degradation of azo dye using non-thermal plasma advanced oxidation process in a circulatory airtight reactor system Effects of dielectric barrier discharge plasma on inactivation and the physicochemical and sensory characteristics of pork loin Chemical analysis of reactive species and antimicrobial activity of water treated by nanosecond pulsed DBD air plasma How to ignite an atmospheric-pressure microwave plasma torch without any additional igniters Assessment of plasma gasification of high caloric waste streams Extraordinary catalysis induced by titanium foil cathode plasma for degradation of water pollutant Study on the performance and mechanism of degradation of toluene with nonthermal plasmas synergized supported TiO 2 /γ-Al2O3 catalyst Inactivation mechanism of non-thermal plasma on microbes: a review Biological effects of nitric oxide generated by an atmospheric pressure gas-plasma on human skin cells Hydrogen production from banyan leaves using an atmospheric-pressure microwave plasma reactor Review of the methods to form hydrogen peroxide in electrical discharge plasma with liquid water Inactivation efficacies and mechanisms of gas plasma and plasma-activated water against Aspergillus flavous spores and biofilms: a comparative study Decomposition of toluene in a rotating glaidarc discharge reactor Aqueous-phase chemistry of electrical discharged plasma in water and in gas-liquid environments. Plasma Chemistry and Catalysis in Gases and Liquids Aqueous-phase chemistry and bactericidal effects from an air discharge plasma in contact with water: evidence for the formation of peroxynitritethrough a pseudo-second-order post-discharge reaction of H 2 O 2 and HNO 2 Formation of ROS and RNS in water electro-sprayed through transient spark discharge in air and their bactericidal effects. Plasma process Microbial decontamination of chicken using atmospheric-plasma bubbles Plasma-catalyst hybrid reactor with CeO 2 / γ-Al2O3 for benzene decomposition with synergetic effect and nano particle byproduct reduction Application of non-thermal plasma reactor and fenton reaction for degradation of ibuprofen The Low-pressure Plasma Processing Environment in Handbook of Physical Vapor Deposition (PVD) Processing Electrochemical incineration of phenolic compounds from the hydrocarbon industry using borondoped diamond electrodes Cold plasma for effective fungal mycotoxin control in foods: mechanisms, Inactivation effects and applications Hazardous gas treatment using atmospheric pressure microwave discharges Non-thermal plasma as a novel strategy for treating or preventing viral infection and associated disease Inactivation of virus and bacteria using cold atmospheric pressure air plasmas and the role of reactive nitrogen species Study of the effects of temperature on syngas composition from pyrolysis of wood pellets using a nitrogen plasma torch Reactive species responsible for the inactivation of feline calicivirus by a two-dimensional array of integrated coaxial microhollow dielectric barrier discharges in air Plasma activated water as resistance inducer against bacterial leaf spot of tomato Simultaneous removal of cadmium ions and phenol from water solution by pulsed corona discharged plasma combine with activated carbon Destruction technologies for polychlorinated biphenyls (PCBs) Degradataion and mineralization of methylene blue by dielectric barrier discharge non-thermal plasma reactor Handbook of plasma processing technology: fundamental, etching, deposition, and surface interactions The 2012 plasma road map Application of plasma technology for treating e-waste: a review Effect of shell powder on removal of metals and volatile organic compounds (VOCs) from resin in atmospheric-pressure microwave plasma reactor Economic and environmental evaluation of flux agents in the vitrification of resin waste: A SWOT analysis Hydrogen and methane production from Styrofoam Waste using an atmospheric-pressure microwave plasma reactor Novel TiO 2 /PANI composites as a disinfectant for the elimination of Escherichia coli and Staphylococcus aureus in aquaculture water Use of cold plasma to inactivate Eschericia coli and physicochemical evaluation in Pumpkin Puree Significant of a non-thermal plasma treatment on LDPE biodegradation with Pseudomonas aeruginosa An overview of advances in biomass gasification Suppressing the formation of NOx and N 2 O in CO 2 / N 2 dielectric barrier discharge plasma by adding CH 4 : scavenger chemistry at work Inactivation efficacy and mechanism of pulsed corona discharge plasma on virus in water Cold atmospheric plasma: charged species and their interactions with cells and tissues Inactivation efficacy of nonthermal plasma-activated solutions against Newcastle disease virus Construction aspects of plasma based technology for waste of electrical and electronic equipment (WEEE) management in urban areas Metals recovery from waste of printed circuit boards processed in plasmatron plasma reactor, 16th IFAC symposium in automation in mining, mineral and metal processing Thermal plasma processing of materials: a review Tetronics International: About Tetronics. Tetronic International Limited Production of hydrogen and nano carbon powders from direct plasmalysis of methane Non-thermal plasmas for non-catalytic and catalytic VOC abatement Production of hydrogen by plasmareforming of methanol Removal micro-pollutants from water in a continuous-flo electrical discharge reactor Water plasma generation under atmospheric pressure for HFC destruction Plasma Catalysis as an Efficient and Sustainable Air Purification Kinetics of inactivation of waterborne enteric viruses by Ozone Inactivation of airborne viruses using a packed bed non-thermal plasma reactor Destruction of PCDD/Fs by gliding arc discharges Review on discharge plasma for water treatment: mechanism, reactor geometris, active species and combined process Degradation of cefexime antibiotic in water by atmospheric plasma bubbles: performance, degradation pathways and toxicity evaluation Degradation of cefexime antibiotic in water by atmospheric plasma bubbles: performance, degradation pathways and toxicity evaluation Atmospheric cold plasma jet for plant disease treatment Underwater microplasma bubbles for efficient and simultaneous degradation of mixed dye pollutants Underwater microplasma bubbles for efficient and simultaneous degradation of mixed dye pollutants Characteristics of atmospheric pressure plasma jets emerging into ambient air and helium Effectof cold atmospheric plasmas on adenoviruses in solution Non-combustion technologies for POPs destruction This current work is financially supported by the Chung Yuan Christian University (CYCU) with contract number 109609432. The first author would like to thank Prof. Ya-Fen Wang for supporting the work of this manuscript. We thank the Department of Environmental Engineering, Chung Yuan Christian University, where the study was undertaken. Supplementary data associated with this article can be found in the online version at doi:10.1016/j.jhazmat.2021.127390.