key: cord-1034170-ekg91hmi authors: Poon, Leo L.M.; Peiris, J.S. Malik title: Detection of Group 1 Coronaviruses in Bats Using Universal Coronavirus Reverse Transcription Polymerase Chain Reactions date: 2007-11-28 journal: SARS- and Other Coronaviruses DOI: 10.1007/978-1-59745-181-9_2 sha: 6386a2d4105dc1c910c82f5e5e1b846d3288f486 doc_id: 1034170 cord_uid: ekg91hmi The zoonotic transmission of SARS coronavirus from animals to humans revealed the potential impact of coronaviruses on mankind. This incident also triggered several surveillance programs to hunt for novel coronaviruses in human and wildlife populations. Using classical RT-PCR assays that target a highly conserved sequence among coronaviruses, we identified the first coronaviruses in bats. These assays and the cloning and sequencing of the PCR products are described in this chapter. Using the same approach in our subsequent studies, we further detected several novel coronaviruses in bats. These findings highlighted the fact that bats are important reservoirs for coronaviruses. Coronaviruses are a group of enveloped, positive-strand single stranded RNA viruses with a corona-like morphology. These viruses have genome sizes ranging from 28 to 32 kb, which makes them the biggest among the RNA viruses (1). The genomes contain five major open reading frames (Orfs) that encode the replicase polyproteins (Orf 1a and Orf 1ab), spike (S), envelope (E), membrane (M), and nucleocapsid (N) proteins, in that order. Based on antigenic and genetic analyses, coronaviruses can be subdivided into three groups. Coronaviruses from groups 1 and 2 have been found to infect mammals. By contrast, avian species are known to be the natural hosts for group 3 viruses. Most coronaviruses hosts (2,3) . Animal coronaviruses are known to cause respiratory, gastrointestinal, neurological, and hepatic diseases. By contrast, with the exception of SARS coronavirus, in the case of healthy individuals all previously known human coronaviruses were generally only associated with mild respiratory and gastrointestinal diseases. The discovery of a novel coronavirus as the cause of SARS led to a resurgence in interest in these viruses and to the discovery of other novel coronaviruses in humans, namely NL-63 and HKU-1 (4-6). The recognition of SARS-like coronaviruses in palm civets and other small mammals in live-game animal markets (7) prompted intensive surveillance for coronaviruses in wild animals. Following upon this interesting discovery, several novel coronaviruses were identified in the mammalian and avian species (6, (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) . In particular, our initial studies first revealed that bats are important reservoirs for coronaviruses. By screening respiratory and fecal samples collected from a wide range of animals, we identified the first coronavirus in bats (14) . Subsequent studies by ourselves and others also indicated that there are number of group 1 and group 2 viruses circulating in bat species (11, 12, 15, 17) . In particular, a SARS-like coronavirus was found in two of these studies independently (11, 12) . These results suggest that bats might play a key role in the evolution of coronaviruses. Here we describe the procedures that were used in our virus surveillance studies. The protocol described below was used to detect group 1 bat coronavirus in our previous studies (14 ) . The procedures and primer set for the assay can also detect other non-group-1 coronaviruses in other specimens. In our studies, this assay was also shown to be able to detect other common human coronaviruses in our hands (e.g., HKU1, NL63, OC43, and 229E). As the primer set used in our studies would cross-react with a wide range of coronaviruses (Fig. 1) , all the positive products from the PCR reactions should first be identified by DNA sequencing. Moreover, amplicons from our PCR assays were sometimes found to contain many single-nucleotide polymorphisms. To obtain more accurate sequencing data for our phylogenetic analysis, PCR products from these reactions were cloned into vectors (Section 3.8) and several clones from the same PCR reactions were chosen for sequencing analysis. To enhance the detection rate of bat coronaviruses, we also developed a heminested PCR assay to detect group 1 bat corornaviruses identified from our earlier study (Section 3.6) (8). However, we did not evaluate the performance of this hemi-nested PCR assay to detect other coronaviruses. 1. Trap the animal with a sampling net and handle it with appropriate protective equipment (e.g., cotton work gloves or leather gloves) (see Notes 4 and 5). 2. Examine the animal and record its physical parameters/features for species identification. 3. For collecting throat swab samples, insert swab into the animal's throat and leave it in place for a few seconds to absorb secretions. For collecting anal swab samples, insert swab into the anus and leave it in place for a few seconds (see Note 6). 4. Immediately place the swab into a sterile vial containing 1 ml of viral transport medium. Label each specimen properly. 5. Put the specimen vials on ice for transport to the laboratory. Do not freeze. 6. Vortex the specimen vial briefly in the laboratory. Transfer 500 l of viral transport medium into a new sterile vial at -70 • C for long-term storage. If the remaining half of the sample cannot be processed for RNA extraction (or virus isolation) on the same day, store it at 4 • C until use (see Note 7). 1. For a new kit, perform the following procedures before specimen processing: a. Add 1 ml of buffer AVL to a tube of lyophilized carrier RNA (310 g). Dissolve carrier RNA thoroughly. Transfer to the buffer AVL bottle and mix thoroughly. Store the buffer AVL at 4 • C for up to 6 months. b. For every 19 ml of buffer AW1, add 25 ml of ethanol (96-100%). Mix well. Store the buffer AW1 at room temperature for up to 12 months. c. For every 13 ml of buffer AW2, add 30 ml of ethanol (96-100%). Mix well. Store the buffer AW1 at room temperature for up to 12 months (see Note 2). 2. Equilibrate all reagents to room temperature before use. 3. Pipette 140 l of the sample into a 1.5-ml microcentrifuge tube. 4. Add 560 l of prepared buffered AVL with carrier RNA to the microcentrifuge tube. 5. Briefly vortex the tubes for 15 sec and incubate at room temperature for 10 min. 6 . Briefly centrifuge the microcentrifuge tube. Add 560 l ethanol (96-100%) and mix by pulse vortexing for 15 sec. 7. Briefly centrifuge the microcentrifuge tube. 8. Transfer 630 l of the solution from the tube to a QIAamp spin column placed in a 2-ml collection tube. Centrifuge at 6000 × g (8000 rpm) for 1 min. Place the spin column in a clean 2-ml collection tube. Discard the tube containing the filtrate. 9. Open the spin column and repeat step 8. 10. Add 500 l buffer AW1. Centrifuge at 6000 × g (8000 rpm) for 1 min. Place the spin column in a clean 2-ml collection tube. Discard the tube containing the filtrate. 11. Add 500 l buffer AW2. Centrifuge at 20,000 × g (14,000 rpm) for 3 min. Place the spin column in a clean 2-ml collection tube and centrifuge at 20,000 × g again for 1 min. Place the spin column in a clean 1.5-ml microcentrifuge tube. Discard the tube containing the filtrate. 12. Apply 60 l buffer AVE equilibrated to room temperature directly on the membrane of the column. Close the cap and incubate at room temperature for 1 min. 13. Centrifuge at 6000 × g (8000 rpm) for 1 min. Collect the filtrate for cDNA synthesis. Store the RNA at -20 • C or -70 • C (see Note 8). 1. Prepare a reverse transcription master mix sufficient for the designated number (N) of samples in a sterile 1.5-ml microcentrifuge tube as shown in Table 1 1. Prepare a PCR master mix sufficient for the designated number of samples in a sterile 0.5-ml microcentrifuge tube according to Table 2 . Include at least 1 positive control and 1 negative control (water) for each run. Add additional controls (e.g., purified RNA from the studied samples) as necessary. 2. Vortex and centrifuge the tube briefly. Keep the tube on ice. 3. Aliquot 48 l of the master mix into separate 0.5-ml microcentrifuge tubes and label the tubes accordingly. 4. Add 2 l of cDNA generated from the reverse transcription reactions to the tubes. For the positive control, add 2 l of coronavirus cDNA into the reaction. For the negative control, add 2 l of autoclaved water. 5. Vortex and centrifuge the tubes briefly. 6. Run the PCR under the conditions shown in Table 3 . 7. After the run, analyze the PCR products by gel electrophoresis. Before gel electrophoresis, the PCR reactions can be kept at -20 • C for short-term storage. 6 . Place the tray in the electrophoresis chamber with the wells on the cathode side. 7. Fill the buffer chamber with 1X TAE buffer at a level that can cover the top of the gel. 8. Mix 0.5 l of the DNA markers with 1 l of 6X gel loading dye and 4.5 l of water on a parafilm sheet by repeated pipetting. 9. Mix 5 l of the PCR products with 1 l of 6X gel loading dye on a parafilm sheet by pipetting up and down several times. 10. Apply the mixture to the corresponding well of the gel. 11. Close the lid of the electrophoresis apparatus and connect the electrical leads, anode to anode (red to red) and cathode to cathode (black to black). 12. Run the gel at 100 V for 30 min. 13. Turn off the power, remove the cover, and retrieve the gel. 14. Soak the gel in 1X TAE with 0.5 g/ml ethidium bromide for 15 min. Wash the gel with water (see Note 3). 15 . Place the gel on top of the transilluminator. Switch on the power of the gel documentation machine (see Note 11). 16 . Adjust the position of the gel and record the results. The size of the expected product for coronaviruses is 440 bp (Fig. 2) . 1. Mix 1 l of the the PCR reaction from Section 3.4 with 9 l of water. Use 2 l of the diluted samples in the hemi-nested PCR reaction. 2. Repeat the procedure as outlined in Section 3.4, replacing the reverse primer of the PCR reaction by the primer 5 ATCAGATAGAATCATCATAGAGA-3 . 3. Repeat the steps in Section 3.5. The size of the expected PCR product is 435 bp. 7. Transfer 2 l of reaction product into the thawed competent cells. Mix the contents by gently tapping the tube. 8. Carefully transfer the competent cells to an ice-chilled cuvette. Try to avoid forming bubbles in the cuvette. 9. Insert the cuvette into the electroporation chamber. Transfect the cells under these parameters: 2.5 kV, 200 ⍀, and 25 F. 10. Add 250 l SOC medium provided from the cloning kit to the transfected cells. 11. Tranfect the solution into a 1.5-ml microcentrifuge tube and incubate it at 37 • C with shaking. 12. Spread 100 l of the incubated solution on a prewarmed selective plate. Incubate the plate at 37 • C overnight in an inverted position. 13. Select 5 to 10 white colonies for PCR screening. Use sterile pipette tips to touch the selected colonies. Preserve the selected colonies by touching the pipette tips on a patch LB plate. Label the colonies accordingly. Incubate the plate at 37 • C in an inverted position. Keep the plate at 4 • C after an overnight incubation. 14. Transfer the rest of the contents attached to the pipette tips into 0.5-l microcentrifuge tubes containing 20 l of 10 mM Tris-HCl, pH 7.4. Label the tubes accordingly. Vortex the tubes briefly. 15. Heat the tubes at 95 • C for 10 min. Then chill them on ice and centrifuge briefly. 16 . Depending on the source of the PCR products, repeat the PCR protocol as described in Section 3.4 or 3.6. Use 2 l of heat-treated supernatants as the DNA template in these reactions. 17. Analyze the size of the inserts of these clones according to the procedures described in Section 3.5. Only those with the expected product sizes (i.e., 440 bp for protocol 3.4; 435 bp for protocol 3.6) will be selected for PCR sequencing. Purify the positive samples as described in Section 3.7 before DNA sequencing. 18. Pick the desired clones off the patch plate and put them into 1 ml of LB containing 50 g/ml of ampicillin. Grow the culture for 16-20 h. Mix 0.85 ml of the culture with 0.15 ml of sterile glycerol. Keep the transformed cells at -80 • C for long-term storage. Table 4 . 4. Store the reaction products at 4 • C until ready for purification. 5. Briefly vortex the dye removal columns to resuspend the gel. 6. Snap off the tip, remove the cap, and insert it into a clean microcentrifuge tube from the purification kit. 7. Centrifuge the tube at 1000 × g (3300 rpm) for 2 min. 8. Discard the flow-through. 9. Apply 200 l of water to each column. Centrifuge the tube at 1000 × g (3300 rpm) for 2 min. Transfer the columns into clean microcentrifuge tubes. 10. Carefully apply the sequencing products (∼20 l) to the gel matrix in the columns. 11. Centrifuge the tube at 1000 × g (3300 rpm) for 2 min. Discard the columns and store the tubes containing the purified sequencing products at -20 • C. 12. Transfer 10 l of the purified products to a 96-well sample loading plate. Seal the plate with a heat seal and load it into the DNA analyzer for analysis. 13. Run the DNA analyzer. 14. Analyze the deduced sequences (see Notes 14 and 15). 1. Viral transport medium contains a high concentration of antibiotic to inhibit bacterial growth. 2. Buffer AVL containing carried RNA might form white precipitates when it is stored at 4 • C. The precipitates can be dissolved in the buffer by heating the bottle in a water bath. Cool the buffer to room temperature before use. 3. Ethidium bromide is a known mutagen and may be carcinogenic. Handle solutions of ethidium bromide with gloves. 4. For reasons of safety, staffs who are required to handle animals should have the appropriate inoculations (e.g., rabies vaccine for handling bats). Appropriate protective equipment should be worn when handling animals. 5. Bats are protected species in Hong Kong, and a permit from the relevant governmental office is required to perform the work. 6 . For some small bat species, the finest swabs used in our studies are still too big to fit into the anal opening. In this situation, we use fecal instead of anal samples. To minimize possible contamination, these bats are kept individually in clean cotton bags for a few minutes. Fecal pellets collected in the cotton bags are sampled for further analysis. 7. In our study, we also tried to isolate viruses from our samples. As some viruses might be sensitive to repeat freeze and thaw cycles, we normally aliquot the original samples into two separate tubes. One tube is kept at -80 • C for long-term storage and the other is kept at 4 • C until it is ready for RNA extraction and virus isolation. 8. Contents in fecal samples and calcium alginate in swabs are known to inhibit RT-PCR assays. One should validate the protocols and test the reagents with specimens spiked with positive samples in advance. RNA purified from our recommended RNA extraction kit work well for us. 9. General procedures to prevent PCR cross-contamination should be strictly followed. Aerosol-resistant filtered pipette tips could minimize possible carryover of amplicons. Separate pipettes and areas are used for sample processing, PCR, and post-PCR analysis. It is essential to include multiple positive and negative controls in the PCR reactions when a large number of samples are tested at the same time. 10. Agarose solutions can be superheated in a microwave oven. Do not handle the bottle immediately after microwaving. Always wear heat-resistant gloves when handling melted agarose. 11. UV light can cause severe skin and eye damage. Wear safety glasses and close the photography hood before turning on the UV transilluminator. 12. Purified PCR products from Section 3.7 can be directly subjected to DNA sequencing. As quiescent species were found in our studied bat samples, we observed several single nucleotide polymorphisms in the products. To obtain more accurate sequencing data for our phylogenetic analysis, PCR products from these reactions were cloned into vectors (Section 3.8) and several clones from the same PCR reaction were randomly selected for further analysis. 13. On some occasions, nonspecific PCR products might be observed (lane 8, Fig. 1 ) and the desired PCR products have to be recovered by direct excisions from the agarose gel. As UV can damage DNA, it is important to use low-energy UV light to visualize and locate the desired product in this scenario. Try to excise the product as quickly as possible. We normally purify the excised products using a QIAquick gel extraction kit (Qiagen). The purified products can be subjected to cloning or sequencing as noted. 14. The products should be sequenced in both directions. 15. Deduced sequences are normally analyzed on both DNA and amino acid levels. Common sequence databases, such as Genbank (http://www.ncbi.nlm.nih.gov/ Genbank/) can be used for the analysis. Common analytic freeware such as BioEdit (http://www.mbio.ncsu.edu/BioEdit/bioedit.html) and MEGA (http:// www.megasoftware.net/) are commonly used analytical programs and are available on the Internet. 5X first-strand buffer: 250 mM Tris-HCl (pH 8.3), 375 mM KCl, 15 mM MgCl BigDye Terminator v3.1 Cycle Sequencing kit (Applied Biosystems) Dye terminator removal columns (Genetix) Applied Biosystems) or equivalent When using a new PCR product purification kit, add ethanol (96-100%) to buffer PE according the product insert. Vortex the mixture briefly Apply the mixture to a QIAquick column that is inserted in a 2-ml collection tube Centrifuge the tube at 20,000 × g (14,000 rpm) for 1 min Apply 0.75 ml of buffer PE to the column and repeat step 4 Transfer the column in a sterile 1.5-ml microcentrifuge tube Apply 30 l of buffer EB to the membrane of the column. Let it stand for 1 min Centrifuge the tube at 20,000 × g (14,000 rpm) for 1 min Discard the column. The PCR products collected in the 1.5-ml microcentrifuge tube are ready for sequencing work (Section 3.9). Alternatively, these samples could be stored at -20 • C until use (see Notes Cloning (Optional) On the day of the work, spread 40 l of 40 mg/ml X-gal on selective agar plates, each of which contains 50 g/ml ampicillin. Incubate the plates at 37 • C until use Dilute the salt solution provided in the cloning kit by fourfold Thaw a vial of electrocompetent E. coli on ice Mix 4 l of purified PCR products from Section 3.7 with 2 l of fourfold diluted salt solution in a sterile 0.5-ml microcentrifuge tube by pipetting up and down several times Mix 1 l TOPO vector into the reaction with a gentle pipetting Nidovirales: evolving the largest RNA virus genome Animal coronavirus vaccines: lessons for SARS Coronavirus pathogenesis and the emerging pathogen severe acute respiratory syndrome coronavirus. Microbiol A previously undescribed coronavirus associated with respiratory disease in humans Identification of a new human coronavirus Characterization and complete genome sequence of a novel coronavirus, coronavirus HKU1, from patients with pneumonia Isolation and characterization of viruses related to the SARS coronavirus from animals in southern China Coronaviruses in bent-winged bats (Miniopterus spp Coronavirus infection of spotted hyenas in the Serengeti ecosystem Molecular identification and characterization of novel coronaviruses infecting graylag geese (Anser anser), feral pigeons (Columbia livia) and mallards (Anas platyrhynchos) Severe acute respiratory syndrome coronavirus-like virus in Chinese horseshoe bats Bats are natural reservoirs of SARS-like coronaviruses Coronavirus outbreak in cheetahs: lessons for SARS Identification of a novel coronavirus in bats Prevalence and genetic diversity of coronaviruses in bats from Molecular characterization of a novel coronavirus associated with epizootic catarrhal enteritis (ECE) in ferrets Molecular diversity of coronaviruses in bats Funding