key: cord-1033397-6j2igryk authors: Kevill, Jessica L.; Pellett, Cameron; Farkas, Kata; Brown, Mathew R.; Bassano, Irene; Denise, Hubert; McDonald, James E.; Malham, Shelagh K.; Porter, Jonathan; Warren, Jonathan; Evens, Nicholas P.; Paterson, Steve; Singer, Andrew C.; Jones, Davey L. title: A comparison of precipitation and filtration-based SARS-CoV-2 recovery methods and the influence of temperature, turbidity, and surfactant load in urban wastewater date: 2021-11-24 journal: Sci Total Environ DOI: 10.1016/j.scitotenv.2021.151916 sha: f789893489770c9e25d91a40ca5ab0b9714d4ec4 doc_id: 1033397 cord_uid: 6j2igryk Wastewater-based epidemiology (WBE) has become a complimentary surveillance tool during the SARS-CoV-2 pandemic. Viral concentration methods from wastewater are still being optimised and compared, whilst viral recovery under different wastewater characteristics and storage temperatures remains poorly understood. Using urban wastewater samples, we tested three viral concentration methods; polyethylene glycol precipitation (PEG), ammonium sulphate precipitation (AS), and CP select™ InnovaPrep® (IP) ultrafiltration. We found no major difference in SARS-CoV-2 and faecal indicator virus (crAssphage) recovery from wastewater samples (n = 46) using these methods, PEG slightly (albeit non-significantly), outperformed AS and IP for SARS-CoV-2 detection, as a higher genome copies per litre (gc/l) was recorded for a larger proportion of samples. Next generation sequencing of 8 paired samples revealed non-significant differences in the quality of data between AS and IP, though IP data quality was slightly better and less variable. A controlled experiment assessed the impact of wastewater suspended solids (turbidity; 0–400 NTU), surfactant load (0–200 mg/l), and storage temperature (5–20 °C) on viral recovery using the AS and IP methods. SARS-CoV-2 recoveries were >20% with AS and <10% with IP in turbid samples, whilst viral recoveries for samples with additional surfactant were between 0–18% for AS and 0–5% for IP. Turbidity and sample storage temperature combined had no significant effect on SARS-CoV-2 recovery (p > 0.05), whilst surfactant and storage temperature combined were significant negative correlates (p < 0.001 and p < 0.05, respectively). In conclusion, our results show that choice of methodology had small effect on viral recovery of SARS-CoV-2 and crAssphage in wastewater samples within this study. In contrast, sample turbidity, storage temperature, and surfactant load did affect viral recovery, highlighting the need for careful consideration of the viral concentration methodology used when working with wastewater samples. Coronavirus disease 19 symptoms were first reported in December 2019, by clinicians treating clusters of patients exhibiting pneumonia-like illness, all originating from the Wuhan district of Hubei province, China . The pathogen associated with pneumonia was identified as a novel coronavirus in January 2020 ; an enveloped, single-stranded, positive-sense RNA virus in the family Coronaviridae (Gorbalenya et al., 2020) , later named as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Following the sequencing of SARS-CoV-2, a range of laboratory diagnostics for the virus rapidly emerged, predominantly using reverse transcription quantitative polymerase chain reaction (RT-qPCR) assays (Corman et al., 2020; Li et al., 2020) . These have been a cornerstone in aiding the understanding of infection and transmission rates, pathology and identifying potential infectious sources such as; infected tissues (Casagrande et al., 2020; Jiang et al., n.d.; Vijayan and Humphreys, 2020) , urine, faeces (Cheung et al., 2020; Jeong et al., 2020; Zheng et al., 2020) , as well as spill-over events into animals (Koopmans, 2021; McAloose et al., 2020; Sit et al., 2020; World Health Organization, 2003) . RT-qPCR studies involving hospital patients show that SARS-CoV-2 can be detected at 10 1 to 10 8 genome copies (gc) g -1 in faeces of infected individuals (Cheung et al., 2020; Jeong et al., 2020; Zheng et al., 2020) , whilst viral shedding in urine is uncommon (Huang et al., 2020; Lo et al., 2020) . The presence of SARS-CoV-2 RNA in faeces has therefore led to the adoption of wastewater-based epidemiology (WBE) to assess appear, it can potentially provide an early warning system for community-level COVID-19 outbreaks (Zhu et al., 2021) . In addition to viruses, faecal coliform bacteria and human gut-associated bacteriophages (e.g. CrAssphage) can be detected in wastewater and are used as faecal indicators in WBE programs (Doré et al., 2003; Vázquez-Salvador et al., 2020) . CrAssphage, a group of bacteriophages infecting Bacteroides spp. common in the human gut, are an important human faecal marker as they are regularly detected in wastewater (Farkas et al., 2019; Tandukar et al., 2020) , often in parallel with human enteric viruses (Crank et al., 2020; Farkas et al., 2019) . When wastewater flow rate is high, due to groundwater infiltration and stormwater runoff, crAssphage concentrations in wastewater are low, allowing these data to be used to normalise viral data and account for dilution (Wilder et al., 2021) . The rapid and widespread utilisation of WBE for the monitoring of SARS-CoV-2 has led to the optimisation and comparison of several methods for concentrating enveloped viruses from wastewater, including: ultracentrifugation (Ahmed et al., 2020c) , ultrafiltration (Ahmed et al., 2020c; Forés et al., 2021; Jafferali et al., 2021; LaTurner et al., 2021; McMinn et al., 2021; Philo et al., 2021; Rusiñol et al., 2020) , polyethylene glycol (PEG) and salt-based precipitation (Ahmed et al., 2020c; LaTurner et al., 2021; Pérez-Cataluña et al., 2021; Philo et al., 2021) , skimmed milk flocculation (Philo et al., 2021; Rusiñol et al., 2020) , sludge extraction (Philo et al., 2021) , bag-mediated filtration (Philo et al., 2021) , magnesium-and aluminium-based absorption (Jafferali et al., 2021; Pérez-Cataluña et al., 2021) . The virus (Ahmed et al., 2020c) , porcine epidemic diarrhoea virus (Pérez-Cataluña et al., 2021) , as well as non-enveloped MS2 bacteriophage (Forés et al., 2021) , mengovirus (Pérez-Cataluña et al., 2021) and pepper mild mottle virus (Jafferali et al., 2021) . All these studies report different virus recoveries, and sensitivities amongst methods. However, there is consensus in the literature that both ultrafiltration (Forés et al., 2021; Jafferali et al., 2021; LaTurner et al., 2021) and absorption-based methods (Ahmed et al., 2020c; Pérez-Cataluña et al., 2021) have high sensitivity for the detection of SARS-CoV-2. The efficiency of viral recovery from wastewater is likely to be strongly influenced by the composition of the wastewater, while wastewater which varies according to its source (e.g., domestic-to-industrial ratio), degree of groundwater ingress into the sewer system, and prevailing weather conditions (e.g. dilution with rainwater). For example, it is known that high concentrations of suspended solids can negatively affect the recovery of fecal indicator bacteria and pathogenic organisms (Gedalanga and Olson, 2009; Medeiros and Daniel, 2015) . This is due to the inability to fully desorb organisms either held electrostatically on particle surfaces or embedded in surface biofilms (Gantzer et al., 2008) . Similarly, common domestic cleaning products and surfactants may also influence viral recovery from wastewater (Mousavi and Khodadoost, 2019) . In the case of SARS-CoV-2, surfactants may facilitate desorption from surfaces, however, it may also promote envelope damage leading to greater exposure and degradation of its RNA (Jahromi et al., 2020; Shim et al., 2017) . This study aimed to evaluate the influence of concentration method, sample turbidity, temperature and surfactant concentration on the recovery of SARS-CoV-2 and the faecal indicator, crAssphage, from wastewater. We compared three concentration methods: PEG, ammonium sulphate (AS) precipitation and the CP select™ InnovaPrep ® filtration unit (IP). We hypothesized that high concentrations of suspended solids and surfactants would reduce SARS-CoV-2 recovery and that high temperatures would also induce viral decay and the loss J o u r n a l P r e -p r o o f Journal Pre-proof of viral RNA. The overall aim was to determine the influence of virus concentration methodology and wastewater conditions on the results obtained by national and regional WBE-based COVID-19 surveillance programmes for both RT-qPCR and next generation sequencing (NGS) data. A total of 46 untreated wastewater samples (crude influent) were collected between October 2020 and February 2021 by United Utilities and Dŵr Cymru/Welsh Water as part of the UK national SARS-CoV-2 wastewater surveillance program At each site, 500 ml of crude influent was collected by manual grab sampling between 08.00 and 10.00 h. This reflected peak flow and aimed to capture the highest faecal load . The wastewater treatment plants (WWTP) were located in North Wales (n = 31), Liverpool (n = 12), and Chester (n = 3). These samples were grouped to the environmental wastewater group used for method comparison of PEG vs. AS vs. InnovaPrep and were not seeded with SARS-CoV-2. SARS-CoV-2 detected in these samples is derived from human waste naturally in sewer water. In addition, 20 l of wastewater influent was collected from Chester on the 13 th January to be used in the controlled laboratory experiments in which surfactant and suspended solid load (turbidity) were altered. Samples were transported and stored at 4°C and concentrated within 24 h of collection. All sample processing was conducted in a Biosafety Level 2 (BSL2) laboratory, adhering to WHO and national biosafety guidelines (OMS, 2004) . (Yokoyama et al., 2011) and found to range from 0.05 to 4.43 mg l -1 (mean 0.45 mg l -1 ), values typical of urban wastewater (Palmer and Hatley, 2018) . In both the surfactant and turbidity experiments, negative and positive controls consisted of 50 ml distilled water (dH 2 O). Once samples were prepared, 1 × 10 8 genome copies (gc) l -1 of heat-inactivated SARS-CoV-2 (heat at 56 o C for 30 mins) provided by Cardiff University, was added to all experimental treatments, apart from negative controls and environmental wastewater samples. To determine SARS-CoV-2 genome copies/ul prior to spiking samples, a concentration of 1 x 10 8 gc/ul of heat inactivated SARS-CoV-2 was added to deionised water and extracted as per the nucleic acid extraction method detailed below. The samples were then placed at 5, 15 or 20°C on shaking racks set at 140 rpm, for 24 h. All treatments were J o u r n a l P r e -p r o o f Journal Pre-proof performed in quadruplicate. Heat-inactivated SARS-CoV-2 was used to mimic its noninfectious nature in wastewater and its different physical states (Wurtzer et al., 2021) . A sample of the unmodified and non-seeded wastewater was analysed to assess background levels of SARS-CoV-2 using the AS method detailed below. In total there were 96 samples; 48 with differing turbidity, 36 adjusted for surfactant, 8 positive controls and 4 negative controls. Wastewater samples were seeded with Murine norovirus (MNV) and Pseudomonas virus phi6 (phi6), which were used a process and extraction controls. MNV stock at a concentration of 1 x 10 6 gc/µl was added to all samples including the negative control after the initial clarification step, with the exception of sampled collected after February and those included in the control experiment. A 1 x 10 6 gc/µl phi6 was added to samples collected in February 2021 and the controlled experiment samples. Again, all samples including the negative control were seeded after the initial clarification step, which removed suspended solids by centrifugation from the sample (15,000 g, 4°C, 10 min). The percent recovery was then calculated from the copy number obtained from RT-qPCR for either MNV or phi6 using the seeded negative control as a baseline for total viral recovery. Full details of MNV and phi6 propagation are provided in the supplementary materials. (200 ml, n = 46) and dH 2 O negative controls were poured into sterile 250 ml PPCO centrifuge jars, and centrifuged (15,000 g, 4°C, 10 min). The supernatant (150 ml) was recovered, transferred to a new sterile 250 ml PPCO bottle and pH adjusted to 7.0-7.5 using 1 M NaOH or 0.5 M HCl. PEG-NaCl (50 ml) was then added to each sample, the samples mixed, incubated overnight (4 o C) and then centrifuged (15,000 g, 4°C, 30 min), with the pellet resuspended in 200 µl of phosphate buffer saline (PBS). Concentrates were stored at 4 o C until nucleic acid extraction. The wastewater (200 ml, n = 46) and dH2O negative controls were poured into sterile 250 ml PPCO centrifuge jars, and centrifuged (15,000 g, 4°C, 10 min). The supernatant (150 ml) was transferred to a new 250 ml PPCO bottle containing 57 g of AS (Sigma-Aldrich, Cat. No. A4915). After the AS had dissolved, the samples were incubated at 4°C for 1 h before centrifuging (15,000 g, 4°C, 30 min) and the supernatant discarded. The pellet was resuspended in 200 µl of PBS. Concentrates were stored at 4°C until nucleic acid extraction. The wastewater samples (n = 46) wastewater (200 ml, n = 46) and dH2O negative controls were poured into sterile 250 ml PPCO centrifuge jars, 2 ml of 5% Tween® 20 (Sigma-Aldrich) was added to the samples prior to centrifugation (15,000 g, 4°C, 10 min). One-step RT-qPCR for the SARS-CoV-2 N1, Phi6 and MNV targets was performed using an RNA Ultrasense One-step RT QuantiFast no ROX, 1 x QuantiFast with ROX with 10 pmol of the forward, 10 pmol of the reverse primers and 5 pmol probe, 16 nmol MgSO4 and 1 μg bovine serum albumin (BSA) and 5 µl sample/standard/control. Samples were run on a MicroAmp optical 96 well reaction plate, using the Quantstudio Flex 6. The qPCR settings were 98 o C 5 min, followed by 40 cycles at 95 o C 15 s and 60 o C 1 min increments of 1.6 o C s -1 . Plasmid DNA as described in Farkas et al. (Farkas et al., 2019) and water for non-template controls were used for quantification and quality control. The crAssphage standard slope ranged from 3.349 to 3.55. As such, quantities can be detected below this limit but are susceptible to false negatives. The viral load of seeded SARS-CoV-2 was confirmed by RT-qPCR and this number was used to calculate the percent recovery for samples in the controlled experiment. A total of 8 paired AS and IP wastewater RNA extracts from the environmental wastewater sample group containing naturally occurring viruses only (non-seeded), along with negative and positive controls, were treated with TURBO DNase (DNA free kit, Invitrogen) and then purified using 1.8x RNA XP beads (Beckman Coulter) to reduce non-specific amplification. Data analysis and statistical tests were carried out in R (R Core Team, 2020), utilising the -lme4‖ package for linear mixed-effects models, -dplyr‖ for data manipulation, and -ggplot2‖ for visualisations (Bates et al., 2015; Wickham et al., 2021; Wickham and Sievert, J o u r n a l P r e -p r o o f 2016). All data was checked for normality using the Shapiro-Wilk Test and QQ-plots (provided in the supplementary materials). For the environmental wastewater samples (n = 46), a Kruskal-Wallis test was selected to compare N1 SARS-CoV-2 and crAssphage gene copy (gc) recovery for each method. Wilcoxon signed rank test with a holm adjustment method was used for post-hoc pairwise comparisons. Additionally, one-sample Wilcoxon signed rank exact tests were used to compare each method individually with the assay LOD. The temperature and turbidity datasets for both concentration methods were visualised using boxplots. In addition, a Welch two sample t-test was selected to compare SARS-CoV-2 N1 gc between concentration methods. Again, data for the temperature and surfactant dataset were plotted using boxplots. In addition, a Wilcoxon rank sum test with continuity corrections was selected to compare N1 gc recovery between methods. A linear mixed-effects model (LMM) was fitted by maximum likelihood, with turbidity and temperature or surfactant and temperature, as fixed effects, assessing correlations with N1 gc recovery, both controlling for variation between methods with random effects. Variables were normalised to a mean of 0 and a standard deviation of 1 to allow comparison of coefficients. The models and variables were assessed through p-values determined by one sample t-tests: residual plots of homoscedasticity, prediction accuracy and normality of residuals and by comparing the Akaike information criterion (AIC) with alternate LMM without fixed effects. The method comparisons for environmental wastewater samples was non-normally distributed (p-value < 0.05; Supplementary materials figure S2). The median SARS-CoV-2 recovery was not significantly different between virus concentration methods (Kruskal- Wallis rank sum test: chi-squared 3.23, df 2, p-value 0.20, Fig. 1a) , post-hoc pairwise Wilcoxon signed rank comparisons supported this conclusion finding no significant differences between pairs (p-value > 0.60). Furthermore, sample medians were compared to the assay LOD for each method, which revealed all methods could be considered different to the LOD for SARS-CoV-2 (Wilcoxon signed rank exact tests: p-value < 0.001; Fig. 1a ). However, a Bartlett test indicated variances were not homogeneous between groups (Ksquared 10.89, df 2, p-value < 0.01), suggesting that the PEG method has significantly reduced variance in viral recovery. A comparison of the crAssphage data further indicated no significant differences between methods (Kruskal-Wallis rank sum test: chi-squared 2.53, df 2, p-value 0.28; figure 1b). A comparison of the NGS data for AS and IP methods revealed that for all summary statistics and sequencing quality indicators IP showed an increase in performance and a reduction in variance when compared to AS (Fig.2 Interestingly there was no linear relationship between IP and AS summary statistics and sequencing quality indicators (Fig. 2, Table 1 ). Journal Pre-proof The viral recoveries of SARS-CoV-2 from seeded samples revealed that AS precipitation is significantly more efficient than IP, in both treatments containing large amounts of suspended solids and surfactant (turbid samples Wilcoxon rank sum exact test: pvalue < 0.001; surfactant samples Wilcoxon rank sum test with continuity correction: p-value < 0.05; Fig. 3b & d) . Concentration of SARS-CoV-2 N1 in the turbid samples with AS had median recoveries of 20-40%, whilst IP had median recoveries of 0-10%, suggesting IP efficiency reduced considerably for samples with high turbidites (Fig. 3a & c) . Surfactant load had a considerable effect upon SARS-CoV-2 N1 recovery, with samples in both methods recovering < 20%: median recoveries being 2-13% and 0-6% for AS precipitation and IP respectively (Fig. 3a & c The AS concentration method yielded higher gc/l when compared to that of the IP method, regardless of sample storage temperature and suspended solid load (turbidity). The mean gc/l for samples stored at 5, 15, and 20 o C for AS were 2.36 × 10 7 , 4.10 × 10 7 , and 3.22 × 10 7 , whilst for IP they were 9.01 × 10 6 , 5.33 × 10 6 and 1.15 ×10 6 , respectively (Fig. 4a) . The mean gc/l for samples with an NTU of 25, 50, 100 and 400 for AS were 4.28 × 10 7 , 2.33 × 10 7 , 2.91 × 10 7 and 2.71 × 10 7 , whilst for the IP method they were 6.36 × 10 6 , 5.47 × 10 6 , 5.66 ×10 6 , and 3.65 × 10 6 , respectively (Fig. 4b) . Prior to statistical analysis a Shapiro-Wilk test revealed the data followed a normal distribution (p-value >0.05). A comparison of the N1 mean gc/l for each concentration method revealed that the means differ significantly between J o u r n a l P r e -p r o o f Journal Pre-proof the AS and IP methods (Welch two sample t-test: t = 7.49, df = 25, p-value < 0.001, Fig. 4c ). The results of the linear mixed model for the effect of temperature and turbidity on SARS-CoV-2 N1 recovery show that both temperature and turbidity levels were not significant predictors of gene recovery (ns = p-value > 0.05, Fig. 4d ). Residual plots of homoscedasticity, prediction accuracy and normality of residuals are provided in the supplementary materials (Fig. S3 ). J o u r n a l P r e -p r o o f The AS concentration method yielded similar gc/l when compared to that of the IP method, regardless of sample storage temperature and surfactant load, except for 5 o C which had higher viral recovery. The mean gc/l for samples stored at 5 o C, 15 o C, and 20 o C for AS were 1.34 × 10 7 , 7.37 × 10 6 , and 6.14 × 10 6 , whilst for the IP method they were 5.95 × 10 6 , 3.04 × 10 6 and 3.08 ×10 6 , respectively (Fig. 5a) . The mean gc/l for samples with surfactant loads of 10, 50, and 200 mg/l for AS were 1.26 × 10 7 , 1.24 × 10 7 , and 1.95 × 10 6 , whilst for the IP method they were 5.03 × 10 6 , 5.20 × 10 6 , and 1.86 × 10 6 , respectively (Fig. 5b) . Prior to statistical analysis a Shapiro-Wilk test revealed data was not normally distributed (p-value <0.05). A significant difference between AS and IP recovery methods occurred between the median SARS-CoV-2 N1 gc (Wilcoxon rank sum test with continuity correction: W = 225, pvalue <0.05, Fig. 5c ). Furthermore, the mixed effects model revealed that both temperature and surfactant levels were significant negative correlates with gene recovery (* = p-value < 0.05; *** = p-value <0.001, Fig. 5d ). Residual plots of homoscedasticity, prediction accuracy and normality of residuals are provided in the supplementary materials (Fig. S4 ). J o u r n a l P r e -p r o o f As the COVID-19 pandemic continues and WBE surveillance intensifies, the need for high-throughput sampling and analysis are required. The comparison of different methodologies for concentrating viruses from wastewater shows that there are many considerations when deciding upon a protocol and trade-offs regarding cost, time, and viral recovery may need to be made dependant on the overall and downstream application of the data and samples. Our results show that for the environmental wastewater samples SARS-CoV-2 and crAssphage recovery was consistent regardless of concentration method. Nonetheless, PEG slightly (albeit non-significantly), outperformed AS and IP for the detection of SARS-CoV-2, as less variance in viral load was observed for the SARS-CoV-2 N1 data. This is likely due to the overnight incubation required for PEG , which enhances recovery without degrading the viruses or their genome (Farkas et al., 2017) . The AS and IP methods are significantly less time consuming than PEG precipitation, due to shorter incubation for AS (1hr) and lack of incubation for IP (Table 2) . By examining the literature, we found one pre-print study that precipitated SARS-CoV-2 using AS (Vatansever et al., 2020) , and despite this method being used to precipitate a range of proteins and viruses (Park et al., 2008; Safferman et al., 1988; Shields and Farrah, 1986) , it is the first time that a comparison for the precipitation of SARS-CoV-2 has been made available. Due to the simplicity of the method, the short processing time involved, and availability of AS to be supplied in large volumes, we favoured this method over PEG or IP (Table 2) . Furthermore, the sequencing data shows that AS and IP environmental wastewater samples, had nonsignificant differences for all quality indicators, meaning that samples concentrated with AS J o u r n a l P r e -p r o o f Journal Pre-proof can be used for further downstream analysis. However, it is worth noting that the sequencing quality was slightly better for the IP concentrated samples, a reduction in variance was also observed (this is due to a reduction in sample handling when using the IP method, maintaining the integrity of RNA/DNA). The amount of SARS-CoV-2 recovered from the seeded samples in the controlled experiment was significantly higher for AS than IP. Overall, AS SAR-CoV-2 viral recoveries were between 5%-58%, and 0%-17%, whereas for IP they were between 0%-12% and 0%-10% for samples with adjusted turbidity and surfactant load, respectively. The amount of SARS-CoV-2 recovered from seeded samples with adjusted turbidity differed significantly with AS viral recoveries being ranging between 5%-58 % and IP between 0%-10%. The mean viral load of SARS-CoV-2 seeded samples with increased turbidity also significantly differed between AS and IP concentration methods, as the AS concentration method yielded higher mean viral loads at ~1 x 10 7 than that of the IP method which were ten-fold less at ~1 x 10 6 . SARS-CoV-2 recovery from seeded samples containing high concentrations of SDS were significantly lower for AS and IP compared to what was observed in samples with less SDS. Samples containing SDS at 10 and 50 mg/l concentrated using AS and IP had viral recoveries ranging between 7%-15% and 3%-10%, respectively. J o u r n a l P r e -p r o o f Cost, time, and sample chemistry need to be carefully considered when choosing a concentration method for viral recovery from wastewater. We show all concentration methods we tested are suitable for extracting and quantifying SARS-CoV-2 RNA and crAssphage DNA from wastewater samples. In environments where wastewater turbidity and surfactant load are extremely high it is recommended that a precipitation method rather than an ultrafiltration method is employed. Further work on method refinement should focus on other human viruses that can be detected in wastewater, such as respiratory syncytial virus (RSV), noroviruses, and influenza viruses. In addition, research efforts should be conducted to improve viral recovery from wastewater samples, as the controlled experiment had recoveries of less than 50% for most of the samples. Determining where viruses are lost during the process would be of great benefit, especially in samples with low virus abundance. We thank Prof Andrew Weightman (Cardiff University, UK) for providing the inactivated SARS-CoV-2, and Ian Goodfellow (University of Cambridge, UK) for providing the original MNV stock. The authors declare no conflicts of interest. detection of SARS-CoV-2 in untreated wastewater in Australia: A proof of concept for the wastewater surveillance of COVID-19 in the community Detection of SARS-CoV-2 RNA in commercial passenger aircraft and cruise ship wastewater: a surveillance tool for assessing the presence of COVID-19 infected travellers Comparison of virus concentration methods for the RT-qPCR-based recovery of murine hepatitis virus, a surrogate for SARS-CoV-2 from untreated wastewater Determining the UK's potential for heat recovery from wastewater using steady state and dynamic modelling -preliminary results Fitting linear mixed-effects models using lme4 Detection of SARS-CoV-2 in Human Retinal Biopsies of Deceased COVID-19 Patients Gastrointestinal Manifestations of SARS-CoV-2 Infection and Virus Load in Fecal Samples From a Hong Kong Cohort: Systematic Review and Meta-analysis Escherichia coli in molluscan bivalve shellfish from commercial harvesting areas Critical Evaluation of CrAssphage as a Molecular Marker for Human-Derived Wastewater Contamination in the Aquatic Environment Evaluation of Molecular Methods for the Detection and Quantification of Pathogen-Derived Nucleic Acids in Sediment Concentration and Quantification of SARS-CoV-2 RNA in Wastewater Using Polyethylene Glycol-Based Concentration and qRT-PCR Evaluation of two rapid ultrafiltration-based methods for SARS-CoV-2 concentration from wastewater Poliovirus-1 adsorption onto and desorption from montmorillonite in seawater COVID-19 surveillance in Southeastern Virginia using wastewater-based epidemiology The species Severe acute respiratory syndrome-related coronavirus: classifying 2019-nCoV and naming it SARS-CoV-2 Monitoring SARS-CoV-2 in municipal wastewater to evaluate the success of lockdown measures for controlling COVID-19 in the UK SARS-CoV-2 viral load in clinical samples from critically ill patients Benchmarking virus concentration methods for quantification of SARS-CoV-2 in raw wastewater Viable SARS-CoV-2 in various specimens from COVID-19 patients Direct Evidence of Active SARS-CoV-2 Replication in the Intestine SARS-CoV-2 and the human-animal interface: outbreaks on mink farms MVN: An R Package for Assessing Multivariate Normality First proof of the capability of wastewater surveillance for COVID-19 in India through detection of genetic material of SARS-CoV-2 First detection of SARS-CoV-2 in untreated wastewaters in Italy Polyethylene glycol precipitation for recovery of pathogenic viruses, including hepatitis A virus and human rotavirus, from oyster, water, and sediment samples Laboratory diagnosis of coronavirus disease-2019 (COVID-19) Evaluation of sars-cov-2 rna shedding in clinical specimens and clinical characteristics of 10 patients with COVID-19 in Macau From people to panthera: Natural sars-cov-2 infection in tigers and lions at the bronx zoo Development of a Large Volume Concentration Method for Recovery of Coronavirus from Wastewater Comparison of selected methods for recovery of Giardia spp. cysts and Cryptosporidium spp. oocysts in wastewater Effects of detergents on natural ecosystems and wastewater treatment processes: a review Laboratory biosafety manual 3rd edition, World Health Organization The role of surfactants in wastewater treatment: Impact, removal and future techniques: A critical review Optimum conditions for production and purification of human papillomavirus type 16 L1 protein from Saccharomyces cerevisiae Comparing analytical methods to detect SARS-CoV-2 in wastewater A comparison of SARS-CoV-2 wastewater concentration methods for environmental surveillance Concentration methods for the quantification of coronavirus and other potentially pandemic enveloped virus from wastewater Assessment of recovery efficiency of beef extract reagents for concentrating viruses from municipal wastewater sludge solids by J o u r n a l P r e -p r o o f the organic flocculation procedure First detection of SARS-CoV-2 RNA in wastewater in North America: A study in Louisiana Concentration of viruses in beef extract by flocculation with ammonium sulfate Differential MS2 interaction with food contact surfaces determined by atomic force microscopy and virus recovery Infection of dogs with SARS-CoV-2 Wastewater surveillance for Covid-19: An African perspective Applicability of crAssphage, pepper mild mottle virus, and tobacco mosaic virus as indicators of reduction of enteric viruses during wastewater treatment Bepridil is potent against SARS-CoV-2 in Vitro Household water quality in areas irrigated with wastewater in the Mezquital Valley Novel wastewater surveillance strategy for early detection of coronavirus disease 2019 hotspots SARS-CoV-2 in the kidney: bystander or culprit? A novel coronavirus outbreak of global health concern Detection of SARS-CoV-2 in raw and treated wastewater in Germany -Suitability for COVID-19 surveillance and potential transmission risks A Grammar of Data Manipulation ggplot2 Elegant Graphics for Data Analysis Co-quantification of crAssphage increases confidence in wastewater-based epidemiology for SARS-CoV-2 in low prevalence areas Consensus document on the epidemiology of severe acute respiratory syndrome (SARS), Consensus document on the epidemiology of severe acute respiratory syndrome (SARS) Several forms of SARS-CoV-2 RNA can be detected in wastewaters: Implication for wastewater-based epidemiology and risk assessment Spectrometric determination of anionic surfactants in environmental waters based on anisole extraction of their bis[2-(5-chloro-2-pyridylazo)-5-diethylaminophenolato]cobalt(III) ion pairs Viral load dynamics and disease severity in patients infected with SARS-CoV-2 in Zhejiang province 2021. Early warning of COVID-19 via wastewater-based epidemiology: potential and bottlenecks Data analysis and curation Sequencing data and analysis Final suggested edits ☒ The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.☐The authors declare the following financial interests/personal relationships which may be considered as potential competing interests:The authors declare that there are no competing interests.