key: cord-1033295-5y13z6x5 authors: Del Din, Silvia; Kirk, Cameron; Yarnall, Alison J.; Rochester, Lynn; Hausdorff, Jeffrey M. title: Body-Worn Sensors for Remote Monitoring of Parkinson’s Disease Motor Symptoms: Vision, State of the Art, and Challenges Ahead date: 2021-07-16 journal: Journal of Parkinson's disease DOI: 10.3233/jpd-202471 sha: 463ed43f0b4080365d4d3d8c65150de06f66026d doc_id: 1033295 cord_uid: 5y13z6x5 The increasing prevalence of neurodegenerative conditions such as Parkinson’s disease (PD) and related mobility issues places a serious burden on healthcare systems. The COVID-19 pandemic has reinforced the urgent need for better tools to manage chronic conditions remotely, as regular access to clinics may be problematic. Digital health technology in the form of remote monitoring with body-worn sensors offers significant opportunities for transforming research and revolutionizing the clinical management of PD. Significant efforts are being invested in the development and validation of digital outcomes to support diagnosis and track motor and mobility impairments “off-line”. Imagine being able to remotely assess your patient, understand how well they are functioning, evaluate the impact of any recent medication/intervention, and identify the need for urgent follow-up before overt, irreparable change takes place? This could offer new pragmatic solutions for personalized care and clinical research. So the question remains: how close are we to achieving this? Here, we describe the state-of-the-art based on representative papers published between 2017 and 2020. We focus on remote (i.e., real-world, daily-living) monitoring of PD using body-worn sensors (e.g., accelerometers, inertial measurement units) for assessing motor symptoms and their complications. Despite the tremendous potential, existing challenges exist (e.g., validity, regulatory) that are preventing the widespread clinical adoption of body-worn sensors as a digital outcome. We propose a roadmap with clear recommendations for addressing these challenges and future directions to bring us closer to the implementation and widespread adoption of this important way of improving the clinical care, evaluation, and monitoring of PD. At the 2013 World Congress of the International Society of Posture and Gait Research, a keynote speaker predicted that digital health technology such as body-worn sensors (BWS) would soon become a routine, widely used tool to augment the clinical examination of patients with Parkinson's disease (PD) and, more importantly, enhance patients' quality of life [1] . Accumulating evidence at that time demonstrated that low-cost, easy-to-use BWS could be used in the clinic to provide new information and add needed objectivity to the assessment of PD motor symptoms, gait, and mobility. Use of BWS could, therefore, help patients by enhancing their therapeutic management, function and quality of life, and offer them a personalized approach to their symptoms. Moreover, an emerging, exciting set of studies demonstrated that continuous, "24/7" remote monitoring empowered by BWS had the potential to measure, characterize, and quantify both subtle and large changes in mobility and other critical motor symptoms of a patient with PD, providing a robust comprehensive map of the patient's function and its changes over time. In this vision, a patient would receive a small package in the mail containing a BWS several weeks before a routine clinical exam. After following simple instructions and wearing the device continuously for one week, the information collected would be uploaded to a cloud, automatically analyzed, summarized, sent to the clinician for review and provide feedback to the patient. At the clinical exam, the healthcare professional would read an objective, detailed report on the patient's motor function that could be compared and contrasted to the results of previous years, even before the patient took a single step into the clinic. In this way, the clinical visit would be transformed into a more productive and informed meeting, enhancing clinical care in a truly personalized manner. This optimistic vision has not yet been realized [2, 3] . Nonetheless, at a time when COVID-19 is wreaking havoc throughout the globe, the need has become even greater. In this short review, we provide an overview of the current use of BWS (accelerometers, inertial measurement units (IMUs)) for the remote monitoring of PD motor symptoms, summarize the challenges that must be overcome to achieve that potential, and outline steps that should and are being taken, in the long road ahead [2] to address this important opportunity for improving the evaluation and monitoring of PD motor symptoms. The rapidly expanding field of remote monitoring has been the subject of several recent systematic reviews [4] [5] [6] [7] . Here, we provide an overview of recent representative work (2017-2020) on remote monitoring of PD motor symptoms using BWS (Table 1) . We report studies using BWS for remote monitoring (real-world, at-home and in the community) in both unsupervised or scripted conditions, in order to quantify digital outcomes, focusing on papers related to motor symptoms and motor complications: tremor, bradykinesia, dyskinesia, postural instability, gait disturbances and turning, falls risk, freezing of gait (FoG) and physical activity. Using a previously proposed framework [8] , in Table 1 we report: (a) the clinical concept of interest; (b) quantified digital outcomes; (c) validity: i. criterion validity: digital outcome validated against a reference system, ii. construct validity: digital outcome validated against clinical scales (convergent validity) and/or showed known groups differences (discriminant validity)); (d) digital outcome regulatory/qualification status assessed by regulatory bodies (e.g., EMA, FDA) [9, 10] . Tremor, bradykinesia, dyskinesia, motor fluctuations BWS have been used to automatically detect and evaluate tremor, bradykinesia, dyskinesia and on/ off medication state [11] [12] [13] [14] [15] [16] [17] . The main techniques for identification of these symptoms are based on machine learning (ML) models (e.g., support vector machines (SVM)). Models are usually fed with digital outcomes that are signal-based features (e.g., frequency domain) extracted from the BWS. In terms of criterion validity, studies tend to validate the digital outcome against a reference system (e.g., videos, self-report), using mainly ML techniques, showing good accuracy (>90%) [13, 15, 17] . Construct validity is generally tested utilizing clinical scales (e.g., Unified Parkinson's disease Rating Scale (UPDRS)), but is less explored. Table 1 Representative studies examining remote monitoring of Parkinson's disease (PD) motor symptoms using body worn sensors (BWS), between 2017 and 2020. Validation of digital outcomes has been classified 'yes' for each of the following criteria: 1. criterion validity: if digital outcome has been validated against a gold standard reference in the study cited, or in previous studies; 2. construct validity: if digital outcome has been validated (e.g., correlated) against clinical scales (convergent validity) and/or it has shown significant differences between groups (discriminant validity) in the study cited, or in previous studies. Digital outcome regulated/qualified has been classified 'yes' if BWS and/or digital outcome has received FDA (510K 1 ) or EMA 2 Although preliminary results are promising for some digital outcomes, excluding Farzanehfar et al. [12] , these studies include a limited number of subjects (≤25) and, therefore, the generalizability of ML models and related validity for clinical adoption is problematic. We note using BWS to study rigidity, one of the cardinal symptoms of PD, is especially challenging [18] . The importance of postural instability, gait, and turning as diagnostic, prognostic, and progression markers in PD is well recognized [19] [20] [21] . Nonetheless, static balance tests are usually confined to laboratory environments. Difficulty in identifying and discriminating periods of static, "quiet" standing balance from sedentary behavior during everyday activities (especially using single BWS on the trunk) and achieving a "totally unsupervised" postural instability assessment is challenging. Evaluations of digital outcomes are based on: first identification in the BWS signal of the clinical concept of interest (e.g., gait, turning) using either ML methods or previously validated signal-based methods (e.g., methods developed from lab-based validation against gold standards); and second on the quantification of digital outcomes in the identified segments of the signals. Digital outcomes often include signal-based features (e.g., extracted from the BWS signal -frequency domain) or clinically relevant and "translatable" features (e.g., walking speed). Recent studies on the construct validity of turning and gait corroborated that real-world gait and turning performances of PD were impaired (e.g., slower, more variable, and with lower cadence), compared with older adults [22] [23] [24] and reported moderate correlations with clinical scales (e.g., UPDRS) [25, 26] . Only a few studies have reported criterion validity for digital outcomes, and this was limited to in laboratory or home-like environments [25, 27, 28] . Real-world validation remains challenging and relies mainly on videos as a reference. BWS can help advance our understanding of fall risk. For these concepts of interest, the main techniques are again use of ML models to identify relevant segments of the BWS signals, and then quantification of digital outcomes by using signal-based features or validated clinically relevant digital outcomes (e.g., walking speed, variability). Results show that quality (micro) and quantity (macro) digital outcomes describing gait and turning are associated not only with falls status (fallers vs. non-fallers) but also with PD specific characteristics (e.g., PD fallers showing higher variability than older adult fallers) [27, 29] . Real-world digital outcomes show promising results to quantify novel composite indexes (e.g., combining information on falls rate with walking activity) sensitive to change in fall risk in intervention studies [30] [31] [32] . Despite the availability of real-world falls repositories [33] , methodologies for real-world automatic fall detection remain challenging, prone to the detection of false positives [34] , and not thoroughly addressed in PD [35] . FoG is also notoriously difficult to fully replicate and detect, increasing the potential value of remote monitoring. To elicit FoG episodes, studies have tested participants in both ON and OFF conditions during scripted tests in the lab and home and used ML models [36] [37] [38] . The sensitivity and specificity for FoG detection both increase (88.09% and 88.01% respectively) when personalized (BWS data labeled by the participant, so user-dependent) rather than generic (automatic, user-independent) models are used [36, 37] . Comparisons between freezers and non-freezers indicate that the "quality of turning" digital outcome (e.g., turning angle smaller), rather than quantity of mobility, was impaired in PD freezers [25] . While construct validity is often reported (in terms of moderate relationship with clinical scales and discriminant validity) for fall risk and FoG, criterion validity is often limited to testing in the laboratory, rather than real-world environments for falls risk. Videos and ML techniques are mainly devoted to FoG. Daily-living physical activity is one of the more mature applications of BWS. Outcomes such as the intensity of movement (e.g., energy expenditure, METs, step count) and temporal periods (bouts) of physical activity can be quantified [39] . Quantification of physical activity DMOs are based on features that describe the "magnitude" of BWS signals (e.g., counts, METs) or walking related features (based on identification of events-e.g., steps in the BWS signal for step count). Commercial devices are widely utilized in PD for quantifying physical activity [40] [41] [42] . Although people with PD have lower levels of physical activity compared to older adults (discriminant validity), construct validity provides contrasting results with either no [42] , moderate [43] or strong [44] relationships with clinical scales (e.g., UPDRS, Hoehn and Yahr staging) [40] . Criterion validity was again limited to laboratory-based tests (e.g., MET) rather than realworld environments [44] , where the use of self-report diaries limit validity assessment due to subjectivity and recall issues [42] . Across the clinical concepts of interests presented, the vast majority of studies use a single or combination of BWS for data logging and off-line analysis with developed analytics. Only a few examples developed connected systems (e.g., multiple sensors systems, smartphones) and online/m-health ("cloud") platforms to achieve true remote monitoring in real-time (e.g., REMPARK, PD Monitoring) [14, 45] . These m-health platforms have been used in small studies [45] , focusing on selective aspects (e.g., ON-OFF state). Although good usability and user satisfaction results were reported, feasibility aspects (e.g., limited sensor battery time of 20 hours) for clinical adoption were not thoroughly investigated. Generally, studies using BWS are cross-sectional, with only a few examples assessing the ability to detect change and responsiveness in longitudinal or interventional studies [30, 46] . This aspect needs to be better explored. Only when digital outcomes derived from BWS demonstrate robust criterion and construct validity and equal or superior clinimetric properties (e.g., sensitivity to change, prediction of outcomes) compared to conventional clinical outcomes will their application become widespread. Importantly, except for the Parkinson's Kinetigraph for motor symptoms (tremor, bradykinesia and dyskinesia) [12] and Fitbit for electrocardiogram App [40] , another common characteristic across clinical concepts of interest and BWS is the lack of qualification reports accepted for a PD context of use by regulatory bodies (e.g., EMA, FDA). This absence precludes the widespread clinical adoption of BWS and their related digital outcomes [2] . Therefore, despite the promise of BWS for remote monitoring, technical, validity, and regulatory limitations remain significant barriers to their uptake. This brief review of the state-of-the-art shows that, although promising, widespread adoption of BWS in clinical settings is yet to transpire, likely because of several factors. To date, there has been no comprehensive demonstration of criterion ("technical") and construct ("clinical") validity, with differences in BWS and measurement techniques accounting for differences in reporting of results of the same mobility variables [7] . As highlighted earlier, the majority of algorithms that have been developed have not been validated in real-world conditions, which may be due in part to a lack of gold-standard references against which to test. Establishing technical and clinical validity, in addition to the demonstration of feasibility and usability of BWS in patients is essential to obtain qualification approval by regulatory bodies, and, as a consequence, more widespread use of BWS by clinicians [3] . Moreover, to truly transform clinical and research conventions, there needs to be sufficient evidence to show that remote monitoring is clearly "better" in some way (e.g., cost, discriminative and predictive value, clinimetric properties, healthcare economics) than traditional scales and methods. Last year, the Movement Disorder Society (MDS) Task Force on technology published concrete steps to facilitate adoption of BWS in clinical practice [3] . Nonetheless, although there are many examples and attempts in the growing literature to address selective aspects of the Task Force recommendations (e.g., validity and utility), definitive prospective and comprehensive studies are lacking. To move this field forward significantly, previous suggestions included the need to improve cross-discipline communication and larger collaborative efforts. Recent Innovative Medicines Initiative projects (e.g., Mobilise-D (https://www. mobilise-d.eu/), IDEA-FAST (https://idea-fast.eu/)) are paving the way to achieve this. To address this need, we tried to summarize previous recommendations [2, 3, 47, 48] by proposing a roadmap with clear milestones to guide the practical clinical adoption of BWS and digital outcomes ( Fig. 1): 1a. A joint effort between clinicians and end-users (e.g., patient groups [47] ) should identify critical relevant clinical concepts of interest (e.g., gait), related digital outcomes (e.g., real-world walking speed), the context of use, and clinical endpoints (e.g., falls risk). 1b. Select or develop appropriate technology (BWS) with key stakeholders (industry, researchers, clinicians, end-users) for quantification of identified digital outcomes. 2. If not already established, demonstrate criterion (technical, e.g., cross-sectional studies) validity of the digital outcome against a goldstandard reference, in real-world conditions, feasibility, and usability of the BWS for the end-users. This could be achieved, for example, by selecting a digital outcome (e.g., walking speed) and collecting data under controlled conditions with BWS and a gold standard that can quantify the same digital outcome and that can then be used also in realworld conditions. 3. Demonstrate at least equivalent, but preferably superior construct ("clinical", e.g., longitudinal studies) validity of the digital outcome with respect to traditional measures. This could be done, for example, by demonstrating, in a longitudinal study, that the selected digital outcome at baseline (e.g., real walking speed) has stronger correlation (or predictive power) with the clinical endpoint of interest (e.g., perspective number of falls) than clinical scales or questionnaires (e.g., UPDRS III). 4. Describe the context of use and validation work for submission to qualification/ regulatory bodies for approval (EMA, FDA). 5. Demonstrate cost-effectiveness (e.g., saving time of the clinician, improving the quality of life of patients). The barrier for adoption of low-cost solutions is lower than that of solutions that require large monetary investments. This could be demonstrated by carrying out a cost-effectiveness analysis, for example, by quantifying the cost of the BWS (both in monetary and time/effort terms) versus that of a gold standard or clinical assessment and showing evidence of a lower healthcare expenditures and better outcomes achieved with BWS (e.g., as described in recommendation 3). Although BWS and digital outcomes have shown potential for clinical management, they have not yet achieved widespread clinical adoption. We can imagine a future where true remote monitoring of digital outcomes is used to enhance PD diagnosis, monitor progression, and facilitate clinical management. We hope that the recommendations and practical roadmap that are outlined in Fig. 1 will help to move the field forward toward that vision and to better care and monitoring of people with PD. The work was supported by Innovative Medicines Initiative 2 Joint Undertaking (JU) under Grant agreement 820820 (Mobilise-D). The JU receives support from the European Union's Horizon 2020 research and innovation programme and the European Federation of Pharmaceutical Industries and Associations (EFPIA). SDD, AJY and LR are also supported by the Newcastle Biomedical Research Centre (BRC) based at Newcastle upon Tyne and Newcastle University. The work was also supported by the NIHR/Wellcome Trust Clinical Research Facility (CRF) infrastructure at Newcastle upon Tyne Hospitals NHS Foundation Trust. The views expressed are those of the author(s) and not necessarily those of the NIHR or the Department of Health and Social Care or the funders. JH reports having submitted a patent for assessment of mobility using wearable sensors in Parkinson's disease. The intellectual property rights are held by the Tel Aviv Medical Center. All of the authors declare that they have no conflicts of interest. Keynote address: What happens when body-fixed sensors meet parkinsonian gait? A look back to the future Wearable-based mobility monitoring: The long road ahead A roadmap for implementation of patient-centered digital outcome measures in Parkinson's disease obtained using mobile health technologies New sensor and wearable technologies to aid in the diagnosis and treatment monitoring of Parkinson's disease Automated systems based on wearable sensors for the management of Parkinson's disease at home: A systematic review Monitoring motor symptoms during activities of daily living in individuals with Parkinson's disease. Front Neurol 9 Maetzler W (2020) Long-term unsupervised mobility assessment in movement disorders Digital measures that matter to patients: A framework to guide the selection and development of digital measures of health Digital technologies for medicines: Shaping a framework for success Wearable devices in clinical trials: Hype and hypothesis Real-life gait performance as a digital biomarker for motor fluctuations: The Parkinson@Home Validation Study Objective measurement in routine care of people with Parkinson's disease improves outcomes Estimating bradykinesia severity in Parkinson's disease by analysing gait through a waist-worn sensor PD Manager: An mHealth platform for Parkinson's disease patient management A kinematic sensor and algorithm to detect motor fluctuations in Parkinson disease: Validation study under real conditions of use Estimating dyskinesia severity in Parkinson's disease by using a waist-worn sensor: Concurrent validity study A wavelet-based approach to monitoring Parkinson's disease symptoms Using wearables to assess bradykinesia and rigidity in patients with Parkinson's disease: A focused, narrative review of the literature Objective biomarkers of balance and gait for Parkinson's disease using body-worn sensors Gait progression over 6 years in Parkinson's disease: Effects of age, medication, and pathology Gait impairments in Parkinson's disease Real-World Monitoring of PD with Wearables without Parkinson's disease during daily life Quantity and quality of gait and turning in people with multiple sclerosis, Parkinson's disease and matched controls during daily living Digital biomarkers of mobility in Parkinson's disease during daily living Turn around freezing: Community-living turning behavior in people with Parkinson's disease Analysis of correlation between an accelerometer-based algorithm for detecting parkinsonian gait and UPDRS subscales Effect of fear of falling on turning performance in Parkinson's disease in the lab and at home Validation of a step detection algorithm during straight walking and turning in patients with Parkinson's disease and older adults using an inertial measurement unit at the lower back Analysis of free-living gait in older adults with and without Parkinson's disease and with and without a history of falls: Identifying generic and disease-specific characteristics Falls risk in relation to activity exposure in high-risk older adults Conceptualizing a dynamic fall risk model including intrinsic risks and exposures Physical activity and different concepts of fall risk estimation in older people-results of the ActiFE-Ulm Study The FARSEE-ING real-world fall repository: A large-scale collaborative database to collect and share sensor signals from real-world falls Methods for the real-world evaluation of fall detection technology: A scoping review Towards holistic freeliving assessment in Parkinson's disease: Unification of gait and fall algorithms with a single accelerometer Home detection of freezing of gait using support vector machines through a single waist-worn triaxial accelerometer A waistworn inertial measurement unit for long-term monitoring of Parkinson's disease patients Using wearable sensors and machine learning to automatically detect freezing of gait during a FOG-provoking test Parkinsonian deficits in sensory integration for postural control: Temporal response to changes in visual input Quantifying physical activity in early Parkinson disease using a commercial activity monitor Impact of motor fluctuations on real-life gait in Parkinson's patients Continuous quantitative monitoring of physical activity in Parkinson's disease patients by using wearable devices: A case-control study Associations between daily-living physical activity and laboratorybased assessments of motor severity in patients with falls and Parkinson's disease The relationships between three-axis accelerometer measures of physical activity and motor symptoms in patients with Parkinson's disease: A single-center pilot study A "HOLTER" for Parkinson's disease: Validation of the ability to detect on-off states using the REMPARK system Entropy of real-world gait in Parkinson's disease determined Real-World Monitoring of PD with Wearables S47 from wearable sensors as a digital marker of altered ambulatory behavior Integrated and patient-centred management of Parkinson's disease: A network model for reshaping chronic neurological care A clinical view on the development of technology-based tools in managing Parkinson's disease Automated assessment of bradykinesia and dyskinesia in Parkinson's disease Dyskinesia and motor state detection in Parkinson's disease patients with a single movement sensor Algorithm for turning detection and analysis validated under home-like conditions in patients with Parkinson's disease and older adults using a 6 degree-of-freedom inertial measurement unit at the lower back Continuous monitoring of turning in patients with movement disability Validity of Mobility Lab (version 2) for gait assessment in young adults, older adults and Parkinson's disease The impact of freezing of gait on balance perception and mobility in community-living With Parkinson's disease Validation of an accelerometer to quantify a comprehensive battery of gait characteristics in healthy older adults and Parkinson's disease: Toward clinical and at home use Detecting free-living steps and walking bouts: Validating an algorithm for macro gait analysis Deep learning approaches for detecting freezing of gait in Parkinson's disease patients through onbody acceleration sensors Large scale population assessment of physical activity using wrist worn accelerometers: The UK Biobank Study Accuracy of wearable physical activity trackers in people with Parkinson's disease Real-time estimation of daily physical activity intensity by a triaxial accelerometer and a gravity-removal classification algorithm