key: cord-1033140-o41re8uh authors: Li, Xiao; Qin, Zhen; Fu, Hao; Li, Ted; Peng, Ran; Li, Zhijie; Rini, James M.; Liu, Xinyu title: Enhancing performance of paper-based electrochemical impedance spectroscopy nanobiosensors: An experimental approach date: 2020-10-12 journal: Biosens Bioelectron DOI: 10.1016/j.bios.2020.112672 sha: 3b49d3011082fb39b155f0db2419f4f5f93e9481 doc_id: 1033140 cord_uid: o41re8uh Accurate, rapid, and low-cost molecular diagnostics is essential in managing outbreaks of infectious diseases, such as the pandemic of coronavirus disease (COVID-19). Accordingly, microfluidic paper-based analytical devices (μPADs) have emerged as promising diagnostic tools. Among the extensive efforts to improve the performance and usability of μPADs, electrochemical impedance spectroscopy (EIS) based sensing mechanisms have shown great promise, because of their high sensitivity and label-free operations. However, the method to improve EIS biosensing on μPADs is less explored. Here, we present an experimental approach to enhancing the biosensing performance of paper-based EIS nanobiosensors with working electrodes (WEs) decorated with vertically grown zinc oxide nanowires (ZnO NWs). Through a comparison among different EIS settings and an examination of ZnO-WE effects on EIS measurements, we show that Faradaic processes with Fe-based electron mediators are more reliable for ZnO-NW-enhanced working electrodes. We calibrate sensors featuring varied morphologies of ZnO NWs and achieve a low limit of detection (0.4 pg ml(−1)) for detecting p24 antigen as a marker for human immunodeficiency virus (HIV). Through theoretical analysis, imaging, and electrochemical characterizations, we reveal that the total surface area and electrochemical surface area indicate the sensitivity and sensing range of the EIS nanobiosensors. Finally, we demonstrate that the nanobiosensors are capable of differentiating the concentrations (blank, 10 ng ml(−1), 100 ng ml(−1), and 1 μg ml(−1)) of IgG antibody (CR3022) to SARS-CoV-2 in human serum samples, thus confirming the feasibility of applying the devices to COVID-19 diagnosis. This work provides a methodology that can inform the rational design of high-performance EIS-based μPADs and has the potential to facilitate rapid diagnosis in pandemics. In recent decades, the human society has been recurrently suffering from several severe outbreaks of infectious diseases, including human immunodeficiency virus (HIV), severe acute respiratory syndrome (SARS), swine flu H1N1, middle east respiratory syndrome (MERS), and the current coronavirus disease (COVID-19) (C. Zhu et al., 2020) . These outbreaks have caused tremendous casualties and economic burdens (Bhutta et al., 2014) . Particularly, the pandemic of COVID-19 has led to a record scale of lockdown and economic stasis. Identifying infected persons as early as possible is critical to effective quarantines that can substantially slow down the disease spreading. However, due to the vast number of infected people and limited professional healthcare providers and medical facilities, lab-based diagnostic tests are far from sufficient (McBain et al., 2016) . Therefore, accurate, affordable, and rapid diagnostic tools that can be distributed and implemented outside clinical labs have great potential to help manage such crises (C. Martinez et al., 2010; Perkins, 2011) . Among the diagnostic tools devised through the research and development efforts over the past decades, microfluidic paper-based analytical devices (µPADs) for point-of-care diagnostics have stood out as a particularly promising approach, leveraging the intrinsic properties of paper such as amenability to chemical and physical modifications, disposability, capillarity-driven liquid manipulation, and potential for mass manufacture (Gong and Sinton, 2017; Chen et al., 2019; Rolland and Mourey, 2013; Ying et al., 2020) . These devices are normally used for the detection of biomarkers in body fluids, featuring low-cost fabrication and convenient assay operations (Gong and Sinton, 2017; Yang et al., 2017) . Therefore, they could address the world health organization's "ASSURED" (affordable, sensitive, specific, user-friendly, rapid and robust, equipment-free and deliverable to end-users) principles of diagnostic tools and help meet the rapidly rising demand of diagnosis in an epidemic or pandemic. To fulfill their potential, µPADs ought to have detection performance at least comparable to the gold standard tests (Sher et al., 2017; Yamada et al., 2017) . Therefore, researchers have been exploring a wide variety of sensing techniques and transducing materials on µPADs. The detection of protein markers is essential to deal with outbreaks like HIV and COVID-19, for which a large body of research on µPADs utilizes working principles similar to enzyme-linked immunosorbent assays (ELISAs) (Cheng et al., 2010; Fu et al., 2019; Martinez, 2011) . However, these assays often require multiple labeling and amplifying steps, making the diagnostic operations prone to errors and less convenient. Because of the limitations of conventional ELISAs, electrochemical impedance sensing (EIS) has gained increasing research interest. This sensing mechanism inherently requires no labels, which simplifies the assay operations. With appropriate settings of EIS measurements and analysis of the readouts, one can achieve very high sensitivity. For example, paper-based EIS sensors have been reported for label-free detection of bacteria (Rengaraj et al., 2018) and protein biomarkers (Ruecha et al., 2019) . In another study, singlefrequency EIS measurement on paper-based sensors has been proposed to achieve even more convenient assay operations (Rengaraj et al., 2018; Zhao and Liu, 2016) . These studies utilized carbon ink printed on a paper substrate as the working electrode EIS.We have recently reported µPADs that have zinc oxide nanowires (ZnO NWs) directly synthesized on the carbon ink electrodes for EIS measurement (Li and Liu, 2016) . We showed that the combination of EIS and ZnO NWs could achieve highly sensitive detection of protein biomarkers. Given the great potential of nanomaterial-enhanced EIS on µPADs, it is worth exploring the rational design of stable and high-performance EIS settings. Here we present a systematical investigation on the configurations of EIS paper-based biosensors that are enhanced by ZnO NWs, in the pursuit of optimal sensing performance. Our investigation started with selecting an EIS condition by comparing Faradaic and non-Faradaic EIS processes. The electron mediator of the Faradaic EIS process was also chosen through comparison. Three ZnO-NW configurations were generated by tuning hydrothermal growth conditions, and PADs with varied ZnO-NW were tested in immunoassays. Further analysis of the surface area of ZnO NWs with scanning electron microscopy (SEM) and electrochemical measurements indicates the correlation between sensing performance and ZnO-NW morphology. This article offers insights about ZnO-NW-based EIS biosensing for further explorations in the field of µPADs. The EIS-based immunoassays may be applied to serological testing of antibody markers (IgG, IgM, and IgA) of SARS coronavirus 2 (SARS-CoV-2). The fabrication of the electrochemical µPADs was described in our previous reports (Li et al., 2015b; Li and Liu, 2016) . In brief, chromatography #1 paper pieces were patterned by wax printing and subsequent heating to generate confined hydrophilic areas for electrochemical reactions. A counter electrode (CE) and a reference electrode (RE) were formed in the reaction area by screen-printing conductive inks. This layer of paper was then stacked with the layer of a working electrode (WE) to form a complete paperbased biosensor. A piece of chromatography #1 paper was cut into the shape of WEs by a laser cutter (Fig. 1 ). One side of the paper piece was fully covered by carbon ink. In the circular area of the WE, ZnO NP colloidal solution was attached, and ZnO NWs were subsequently grown through a hydrothermal process (Li et al., 2015a) . The aqueous solution contained hexahydrate (ZNH) as the salt to provide zinc composition in ZnO NWs, and hexamethylenetetramine (HMTA) as a mediator. The density and morphology of the NWs can be controlled by the chemical composition of the hydrothermal solution, as discussed in sections to follow. After NW growth and cleaning, a surface chemistry process was accomplished to immobilize antibody molecules on the surface of the electrode. In the process, ZnO-NW WEs were treated with oxygen plasma, glutaraldehyde, (3-aminopropyl)trimethoxysilane (APTMS), antibody molecule (10 µg ml −1 HIV p24 antibody), and eventually blocking reagent (Cat. No. 11152500, Roche). A potentiostat (Autolab PGSTAT302N, Metrohm) was used in this study to implement electrochemical measurements. In EIS measurement, samples of varied p24 antigen concentrations were dropped to WE. After 15 min incubation, the WE surface was cleaned by a washing buffer. Then it was attached to the layer with an electrochemical reaction zone. After the addition of the EIS reaction solution, EIS measurement was registered. In cyclic voltammetric (CV) measurements, WEs were directly assembled with a reaction zone layer. After the electron-mediator buffer was added to the reaction zone, the potentiostat ran the CV measurements. J o u r n a l P r e -p r o o f To prepare the nanobiosensors for serological antibody testing of COVID-19, 3 μl of SARS-CoV-2 Sprotein RBD was immobilized on the WE and incubated at a 4 °C fridge for 4 hr. The WEs were later washed by 8 μl PBS and blocked with 3 μl ELISA blocking reagent (Cat No. 11112589001, Roche) twice with an interval of 30 min. The blocked WEs were then washed by 8 μl of PBS solution with 0.05 % (v/v) Tween 20 (Cat No. P9416, Sigma). To prepare the serum samples for testing, recombinant IgG antibody (CR3022) to SARS-CoV-2 spike glycoprotein S1 was spiked in human serum (Cat No. P2918, Sigma Aldrich) to mimic the real patient samples at different concentrations. Both the RBD protein and the CR3022 antibody were synthesized by James Rini's laboratory at the University of Toronto. When performing the tests, 3 μl of spiked human serum was applied onto a nanobiosensor WE. The sample was incubated at room temperature for 15 min and washed with 5 μl PBS solution containing 0.05 % (v/v) Tween 20. The WE was assembled in the paper device with CE and RE to form a complete electrochemical cell. In EIS measurement, 4 μl of electron mediator solution was added to the test area. In the outbreak of an infectious disease like COVID-19, identifying infected persons, providing medical attention, and practicing appropriate quarantine are crucial in curbing the spread of the disease. Although standard laboratory tests are available (e.g., polymerase chain reaction (PCR)-based testing of SARS-CoV-2 and ELISA for serological testing of antibodies to SARS-CoV-2), they are usually equipmentdependent, technician-requiring, time-consuming, and expensive. Those characteristics of the laboratory tests made them less accessible for point-of-care diagnosis in non-laboratory settings such as doctor's office, urgent care, cruise ships, and ports of entry. Therefore, it is critical to develop accurate, yet easyto-operate and low-cost diagnostic methods to accurately and timely identify virus carriers, especially asymptomatic carriers. Aiming at early-stage disease diagnosis, we propose to enhance EIS sensing performance on µPADs for the detection of proteins related to infectious diseases including COVID-19. Conventionally, ELISAs are widely used in clinical tests for detecting these proteins, and researchers have integrated ELISA-like assays into µPADs (Cheng et al., 2010; Fu et al., 2019; Martinez, 2011) . However, these ELISA-like sensors commonly require labels and extra steps to amplify the signals, which make the sensors less userfriendly. The extra steps also make the sensors subject to errors and instability. In contrast, EIS sensing does not require labels and is inherently sensitive, because EIS differentiates different electrical components on the working electrodes. Therefore, we consider EIS sensing to be a potentially preferable approach to protein detection for infectious diseases including COVID-19. EIS biosensors belong to the category of so-called affinity-based biosensors, meaning the immobilized capture probes selectively bind with the target molecules, which translates the existence of target J o u r n a l P r e -p r o o f molecules in solution into changes on the surface of transducer (Daniels and Pourmand, 2007; Luo and Davis, 2013) . The EIS mechanism removes the need for labels and thus simplifies detection operations. Compared to other electrical biosensors that measure only the current (amperometry) or voltage (voltammetry) changes in the binding event, EIS sensors measure the impedance in an alternating current (AC) steady-state with a constant DC bias, presenting a spectrum that distinguishes the components on the surface of the transducer electrodes (i.e., WEs). The binding events are typically associated with an increase of specific resistance components, which contributes to the high sensitivity of EIS biosensors. In addition to the simplicity and high sensitivity of the proposed sensing method for virus-caused infectious disease, the low cost of the proposed sensors would make the rapid diagnosis more accessible to economically disadvantaged regions. First, µPADs are made of paper which is a relatively cheap substrate, and their fabrication does not require microfabrication techniques as conventional microfluidic chips do. Second, we proposed a hydrothermal growth method that is facile and requires no expensive facilities, so that the addition of nanowires to the µPADs retains a low cost. Third, the EIS method we proposed removes the need of extra labeling or amplifying chemicals, so the reagents in this sensing method would cost less than conventional ELISA or other highly sensitive methods based on amplifying reagents. Overall, we estimate the cost of each test to be $0.1, based on the amounts of reagents involved in each test and the cost of paper substrates. The WEs used in this study were made with laser-cut paper pieces and carbon ink. Before any treatment, the surface of a carbon-ink-coated paper piece has a non-smooth morphology (Fig. S1 ). As shown in the inset of Fig. 1 , hydrothermal growth generated ZnO NWs that fully covered the surface of carbon ink. Three different growth conditions were utilized to generate varied morphology of ZnO NWs (Table SI) . Concentrations of zinc acetate dihydrate (ZAD) and zinc nitrate hexahydrate (ZNH) were changed proportionately, and lower concentrations lead to thinner NWs. Growth time was also changed because NWs grow longer over time. However, the growth rate significantly decreases due to the depletion of chemical compositions in the growth solution, which happens after 8 h growth. So we limited growth time within 8 h (Li et al., 2015b) . Ammonium hydroxide (AH) was used as a buffer to suppress homogeneous nucleation of ZnO in growth solution and favor heterogeneous nucleation on seeded cellulose fibers (Li et al., 2015a; Xu et al., 2009) . In a series of preliminary experiments, chemical concentrations were explored to tune the thickness of ZnO NWs, where ZAD and ZNH concentrations were kept at a ratio of 2:1. The AH concentrations were adjusted alongside because too much AH would suppress both types of ZnO nucleations, whereas too little AH cannot suppress homogeneous nucleation effectively. The efficacy of affinity-based biosensor relies on the stable immobilization of probe molecules and the blocking reagent to minimize non-specific binding. In this study, ZnO NW surface was treated via an organosilane-based surface chemistry process to introduce probe molecules (p24 antigen) to the surface of ZnO NWs. Block reagent was applied after probe binding to eliminate non-specific binding in the sensing process. This process has proved effective in our previous article (Li et al., 2015b) . (1) cutting paper piece into the shape of electrodes; (2) printing a layer of carbon ink to the paper piece for conductivity; (3) growing ZnO NWs on the carbon ink; (4) immobilizing probe and blocking proteins to the surface of WEs; (5) eventually applying the WE to capture and measure target protein. EIS biosensing has been applied in microscale systems (Jin et al., 2017; Nguyen et al., 2013; Selvam et al., 2017) , and researchers reported improved EIS using WEs decorated with nanomaterials, such as gold nanoparticles and carbon nanotubes (Fayazfar et al., 2014; Yang et al., 2013) .We reported the first design of µPAD with a ZnO-NW-decorated WE for EIS-based detection of protein disease markers (Li and Liu, 2016) . Compared to bulk or PDMS-based microfluidic solutions, the liquid environment held by cellulose fibers of paper forms a different type of electrochemical cell, in terms of diffusion of electrolytes and evaporation rate of liquids. The settings of EIS in this format require tuning to achieve stable performance. We took two steps to improve EIS settings. First, we attempted both non-Faradaic and Faradaic processes. As shown in Fig. S2 One-dimensional NWs brings apparent morphological change to the surface of carbon WEs. We examined how this morphological transition affects readouts from EIS. For comparison, we first tested carbon WEs and ZnO-NP-coated WEs. Each WE was biofunctionalized and blocked. As shown in Fig. S3 , the Nyquist plots of these two WE conditions are fluctuating. Thick-long ZnO-NW WE with biofunctionalization and blocking, on the other hand, shows reliable Nyquist plots (Fig. 3a) . As the instability of ZnO-NP-coated and carbon electrodes mainly occurred at a lower frequency, which illustrates the electrical resistance part of the surface impedance of the electrode, we postulate that biofunctionalization and blocking degenerate the conductivity of WE. In contrast, as shown in Fig. 2 , ZnO NWs (even after biofunctionalization and blocking) drastically lowers the resistance of WEs, which might be the reason for ZnO-NW WEs' reliable performance. The circuit model is displayed in Fig. 3a . The impedance of the circuit can be expressed as , Where ; ; ; √ 1 !, Warburg element; "is the angular frequency; #is the Warburg constant, depending on a few factors including diffusion coefficients of redox species, and concentration of redox species. The Nyquist plots of the circuit feature a dome at higher frequencies whose diameter corresponds to Ret and a 45° slope corresponding to the Warburg element. The Bode modulus and phase plots are shown in Fig. 3b . Impedance modulus decreases with frequency. Phase shows an increase around 10000 Hz. The intention of integrating nanostructures to EIS electrodes is to increase surface area to capture target molecules, and previous reports with nanomaterials have validated the effectiveness (Fayazfar et al., 2014; Yang et al., 2013) . By taking advantage of ZnO-NW morphology tuned by growth solutions, we set out to improve the performance of ZnO-NW-decorated electrodes in EIS. As described previously, there are three ZnO-NW morphologies generated in this study (Table I, Fig. 4a ). Fig. 4b shows Nyquist plots obtained with thick-long ZnO-NW WEs, when PBS samples with varied p24 antigen concentrations were added to the sensor. The diameter of the dome region (corresponding to the resistance of electron transfer) increased with higher p24 antigen concentration. Calibrations with three different ZnO-NW morphologies were performed, and the calibration curves are shown in Fig.s 4c, d , and e. Over the same p24 antigen concentration range, the thick-long ZnO-NW WEs generated the biggest resistance change (about 3 kΩ), and there is no apparent saturation up to the concentration of 1 μg ml −1 . In contrast, medium-short and thin-short ZnO-NW electrodes both had relatively small sensitivity (about 2.2 kΩ for thick short NWs and about 2 kΩ for thin long NWs). Besides, the thin-short ZnO-NW electrodes seemed to reach saturation around 10 ng ml −1 p24 antigen concentration. With the calibration curves in Fig. 4 , we calculated the limit of detection (LOD) of these ZnO-NW sensors. Specifically, we refer to triple the standard deviation of the blank samples (0 concentration) and determine the corresponding sample concentration in the calibration curve. As legends in Fig. 4 show, the LODs achieved with the thick-long, thin-medium, and medium-short ZnO NWs were 0.4 pg ml −1 , 2.3 pg ml −1 , and 1.2 ng ml −1 , respectively. The calibration results with three ZnO-NW conditions suggest a correlation between NW morphology and sensing performance. In order to understand the relationship between the performance of ZnO-NW WEs and the morphology of ZnO NWs, we analyzed the surface areas of the three different ZnO-NW conditions through imaging and electrochemical measurements. The surface areas of ZnO NWs were first calculated based on SEM imaging (Fig. 4a) . The width and length difference over the ZnO-NW conditions is discernible in the images. To estimate the total surface area of ZnO NWs over a unit area, we simplified the NWs into cylindrical. The thickness of ZnO NWs in the middle of their length is assumed to be the uniform width of the cylinder. The surface area of individual NWs and total surface area ratios are organized in Table II We also used electrochemical measurement, specifically CV, to probe the electrochemical surface areas of ZnO NWs (Fig. S4 ). The cathodic current peaks obtained from CV measurements and fitted into linear regressions, as shown in Fig. 4f . According to the Randles-Sevcik equation, the slopes of the linear regressions are proportional to the electrochemical surface area, assuming the diffusion coefficient of electron mediator is the same with the three ZnO-NW conditions. Electrochemical surface areas of the fitting equations are shown for pristine carbon (blue), medium-short NWs (yellow), thin-medium NWs (green), and thick-long NWs (red), respectively. All error bars represent standard deviations (n=5). The calibration curves and the results from the two surface area analyses show that bigger surface areas lead to higher sensitivity and saturation levels in EIS sensing. For example, thick-long ZnO NWs achieved a wide detection range compared to the other two, reflected by the overall resistance change (from 1.7 to 4.7 kΩ) over the tested range (from 0 to 1 μg ml −1 ). Besides, thick-long ZnO NWs demonstrated a better LOD (0.4 pg ml −1 ) compared to the other two (2.3 pg ml −1 and 1.2 ng ml −1 ). These results are consistent with the previous research works where nanomaterials were used to elevate surface areas and consequently sensing performance. In the future, one can estimate the difference in the sensing performance of different ZnO NW morphologies through the microscopic imaging and electrochemical measurements we presented here. There are several possible approaches further to boost the sensing performance of ZnO-NW EIS biosensors even further. For example, by replenishing the ZnO NW growth solution, ZnO NWs could grow longer and thus provide more surface area. But it is worth noting the morphological measurement shows that ZnO NWs grow not only in length but also in width (ZnO NW #1 vs. ZnO NW #2, which have the same growth solution but different growth times). As ZnO NWs grow wider, they suppress each other, and as they grow longer, their tips may fuse to limit the growth. So carefully fine-tuning growth conditions to regulate the dimensions and density of ZnO NWs would be necessary to maximize their surface area. In Table SII , we compare the performance of the paper-based ZnO-NW biosensors in this work with commercial ELISA kits and previously reported biosensors. Different from commercial ELISA kits (Tang and Hewlett, 2010) , the presented nanobiosensors reached a much better limit of detection, cost less, and can be finished in a much shorter time. In comparison to other biosensors that utilize paper substrates (Y. or zinc oxide nanostructures-supported EIS (Perumal et al., 2015) , the approach presented here combines the benefits of these factors to achieve both high sensitivity and low cost. Different from nucleic acid based tests utilizing PCR to detect the viral genetic material in throat or nasal swabs (Udugama et al., 2020) , antibody tests or serology tests reveal the existence of IgM and IgG antibodies, which are markers of immune response and appear in blood accompanying the infection (Lipsitch et al., 2020) . Although PCR-based viral detection is sensitive and can effectively confirm the early SARS-CoV-2 infection (Qin et al., 2020) , the virus specific antibody detection for COVID-19 is also important for the following reasons. (1) Antibody tests do not require sample preparation like PCR and thus can be more effective. (2) They can be a complementary test approach to nucleic acid testing for the diagnosis of suspected cases with negative PCR results. (3) They can also survey for asymptomatic infection to control the virus spread (Tang et al. 2020) . In particular, the paper-based EIS biosensing approach presented here features low cost, high sensitivity, and convenience, which could make the COVID-19 antibody tests more accessible. Recent research has shown that IgM and IgG antiviral antibodies can be detected in the serum samples of patients infected with SARS-CoV-2 Teng et al., 2020) . In this work, we employed our nanobiosensors for the detection of CR3022 antibody (specific to SARS-CoV-2 RBD) in human serum. The assay protocol was the same as the HIV p24 test. The assay was finished in less than 30 min. As shown in Fig. 5 , the test results confirm that the paper-based ZnO-NW biosensors can differentiate the spiked human serum samples at different concentrations (blank, 10 ng ml −1 , 100 ng ml −1 , 1 μg ml −1 ). This demonstrates the feasibility of using our nanobiosensors for COVID-19 diagnosis. 5 . Experimental data of detecting CR3022 antibody (specific to SARS-CoV-2 spike glycoprotein S1) in human serum. Error bars represent standard deviations (n=5). In this work, we presented a systematic investigation and improvement of ZnO-NW-enhanced EIS biosensors in the format of µPADs. The method of directly synthesizing ZnO NWs on µPADs not only retains the merits of facile fabrication and low cost but also allows the convenient fine-tuning of ZnO-NW morphology as an approach to better sensing performance. We showed that the enhanced sensors can achieve high sensitivity in HIV marker p24 antigen detection (LOD down to 0.4 pg ml −1 ). Our analyses on the surface areas based on SEM and electrochemical measurements revealed that this sensing performance enhancement can be attributed to increased surface area ratios. We also demonstrated the capability of the sensors for detecting an antibody specific to the spike glycoprotein S1 of SARS-CoV-2 in human serum as a marker for COVID-19. This work advances the understanding of one-dimensional NW-enhanced EIS biosensing and sheds light on possible approaches to superior EIS biosensing performance by tuning one-dimensional NW morphology. The findings presented here may contribute to the development of accurate and rapid diagnostic tools for managing the crises of infectious diseases. The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. Xinyu Liu: Investigation, Writing, Conceptualization, Supervision, Project administration, Funding acquisition Microsystems & Nanoengineering (2015) 1, 15014