key: cord-1032549-gg1ko6x1 authors: Jerry, Jincy; O’Regan, Edel; O’Sullivan, Louise; Lynch, Maureen; Brady, Deirdre title: Do established infection prevention and control measures prevent spread of SARS-CoV-2 to the hospital environment beyond the patient room? date: 2020-06-23 journal: J Hosp Infect DOI: 10.1016/j.jhin.2020.06.026 sha: 3accd6afc15933a110fab0058a4ead871ac494d0 doc_id: 1032549 cord_uid: gg1ko6x1 The role of the hospital environment in the transmission of infection is well described. With an emerging infection whose mode of transmission is under investigation, strict infection prevention and control measures, including patient isolation, hand hygiene, personal protective equipment that is doffed on exiting the patient room, and environmental cleaning should be implemented to prevent spread. Environmental testing demonstrated that COVID-19 patients contaminated the patient area (11/26, 42.3% of tests) but contamination of general ward areas was minimal (1/30, 3%) and the virus was detected after cleaning on one item only (1/25, 4%) which was noted to be in disrepair. measures have been adopted globally to prevent spread within hospitals. Current guidance recommends hand hygiene, personal protective equipment (PPE) and environmental decontamination [2, 3, 4] . There have been studies examining the contamination of environmental surfaces with SARS-CoV-2 virus [5] and modelling the potential risk for the transmission of COVID-19 in healthcare using a surrogate virus [6] . Best practice in the use of single room accommodation and PPE 3 for preventing spread of infection is to don PPE on entering the room and doff on exiting [7] with hand hygiene performed at relevant times according to the WHO 5 moments for hand hygiene. In addition environmental cleaning reduces the risk to staff and future patients. Patients were placed in single en-suite rooms while undergoing assessment for COVID-19 and moved on into 6-bed cohort rooms on specific wards once a laboratory confirmation of the diagnosis was made. Rooms were cleaned with a chlorine dioxide agent (Tristel FUSE®) once daily and again after discharge with a terminal clean using chlorine dioxide followed by UVC disinfection (SteriPro®). Personal protective equipment including filtering face piece (FFP) 2 or FFP 3 masks, eye protection in the form of goggles or visors, gloves and a long sleeved fluid repellent gown was recommended. In each ward an area was designated as the donning areas for staff confidence. PPE was doffed on leaving the patient room. PPE was not worn while working in the general ward areas e.g. at nurses' stations. As the number of COVID-19 cases increased throughout Ireland and internationally, the demand for PPE increased. In order to preserve its use some centres moved to the wearing of PPE throughout ward areas, within and outside of 4 patient rooms, doffing only on exiting the ward in accordance with WHO interim guidance [8] . We theorised that this could increase the risk of spread to healthcare workers due to widespread contamination of ward areas and inadvertent breaches in practice in relation to PPE such that healthcare staff might self-inoculate with SARS-CoV-2 once outside of the patient room in contaminated PPE. We undertook this study to demonstrate that the infectious COVID-19 patient readily contaminates the patient area but that the combination of infection patients. (Table I) Surface and air samples were analysed for the presence of SARS-CoV-2 RNA by molecular testing using the Cepheid Xpert Xpress SARS-CoV-2 assay (Cepheid AB, Solna, Sweden) under Emergency Use Authorization. The Xpert test platform integrates specimen processing, nucleic acid extraction, reverse transcriptase polymerase chain reaction amplification of SARS-CoV-2 RNA, and amplicon detection in a single cartridge. The assay amplifies 2 nucleic acid targets, namely N2 (nucleocapsid) and E (envelope) wherein N2 is more specific for SARS-CoV-2. Results and Discussion 6 Eighty-one surface swab samples were retrieved for the purposes of the study, 26 from within COVID-19 patient rooms, 25 from COVID-19 patient rooms after discharge and following completion of terminal cleaning and disinfection with additional UVC decontamination and 30 from nurses' stations. Testing of the patient room indicated that the patient easily contaminated the area, with almost half of the tests detecting SARS-CoV-2 (11/26, 42.3%). These areas may have been contaminated by coughing, as they were all in close proximity to the patient's bed or chair, or by spread from the patient's contaminated hands. The remote controller for the bed in two rooms was the most frequently positive site (2/2, 100%). These were located in rooms in the ICU, where the remote is an area frequently handled by staff members while caring for the patient. The bed side rail was the second most frequent (4/6, 66.7%), another area touched frequently by both patient and staff. The handle of the en-suite bathroom door was not found to be contaminated in any of 4 en-suite rooms tested. This may be due to the fact that it was located more than two metres from the patient or that the patient was too unwell to mobilise to use the bathroom. There was just one positive test among the samples taken from cleaned rooms. One call bell was found to be contaminated but was also noted to be in disrepair and unlikely to be easily cleaned. In addition, its placement in the room was beyond the reach of the UVC. Replacement and alternative location was immediately recommended. Subsequently all wards were instructed to review equipment condition and cleaning protocols. One telephone at a nurses' station tested positive for SARS-CoV-2 whereas all desk and computer keyboard samples returned negative results. This might suggest that contamination arose due to the respiratory droplets of an infected staff member rather than transfer of patient virus from the contaminated patient room. The total number of air samples taken was 16, 8 from patient rooms, 8 from corridors of COVID-19 wards. 1 control sample of VTM was reserved as a negative control sample for laboratory testing. None of the air samples taken yielded positive results. While this might reassure us that the virus was not airborne, the absence of 7 a positive control such as a positive result even in near patient testing prevents us from drawing any firm conclusions as we could not validate our sampling method. The hospital environment has long been identified as a source of transmission of other infections within hospitals [9] . Placing patients in accommodation isolated from those without infection, hand hygiene, wearing of appropriate personal protective equipment and thorough environmental cleaning and disinfection have all been recognised as important interventions to prevent and control the spread of infections in hospital. It follows that the same measures be put in place to prevent spread of COVID-19. This study demonstrates that these measures effectively prevented spread of SARS-CoV-2 from contaminated patient rooms to general ward areas. This will inform future management of COVID-19 in the event of resurgence as well as other emerging infectious diseases. WHO China Joint Mission on Coronavirus Disease Infection prevention and control during health care when COVID-19 is suspected Interim guidance Infection Prevention and Control and preparedness for COVID 19 in healthcare settings, third update Acute Hospital Infection Prevention and Control Precautions for Possible or Confirmed COVID 19 in a pandemic setting updated 3rd Environmental contamination by SARS-CoV-2 in a designated hospital for coronavirus disease Pandemic -Let's not forget surfaces Infection Prevention and Control of Epidemic-and Pandemic-Prone Acute Respiratory Infections in Health Care, World Health Organization Rational use of personal protective equipment for coronavirus disease (COVID-19) and considerations during severe shortages, Interim guidance -19)-and-considerations-during-severe-shortages Dancer SJ The role of environmental cleaning in the control of hospital acquired infection The authors wish to acknowledge the support of other members of the departments of Infection Prevention and Control and Clinical Microbiology in conducting the study. None declared. None.