key: cord-1032120-tzexf7ga authors: Feng, Yanmei; Li, Qian; Qiu, Daiyu; Li, Guichen title: Graphene Assisted in the Analysis of Coumarins in Angelicae Pubescentis Radix by Dispersive Liquid–Liquid Microextraction Combined with (1)H-qNMR date: 2021-04-21 journal: Molecules DOI: 10.3390/molecules26092416 sha: 5b273f1f863726d473c163f3c8ae5b4c0a914662 doc_id: 1032120 cord_uid: tzexf7ga The content of active components in traditional Chinese medicine is relatively small, and it is difficult to detect some trace components with modern analytical instruments, so good pretreatment and extraction are very important in the experiment. Graphene was introduced by a dispersive liquid–liquid microextraction method based on solidification of floating organic drop (DLLME-SFO) with graphene/1-dodecyl alcohol used as the extractant, and this method, combined with quantitative proton nuclear magnetic resonance spectroscopy ((1)H-qNMR), was used to simultaneously qualitative and quantitative osthole, columbianadin and isoimperatorin in Angelicae Pubescentis Radix. In this experiment, a magnetic stirrer was used for extraction, all NMR spectra were recorded on a Bruker Advance III 600 MHz spectrometer with dimethyl sulfoxide-d(6) (DMSO-d(6)) as deuterated solvent and pyrazine as the internal standard. The influencing factors and NMR parameters in the extraction process were investigated and optimized. In addition, the methodology of the established method was also examined. The quantitative signals of osthole, columbianadin and isoimperatorin were at a chemical shift of δ6.25–δ6.26 ppm, δ6.83–δ6.85 ppm, and δ6.31–δ6.32 ppm. The linear ranges of osthole, columbianadin and isoimperatorin were all 0.0455–2.2727 mg/mL, and R(2) were 0.9994, 0.9994 and 0.9995, respectively. The limits of detection of osthole, columbianadin and isoimperatorin were 0.0660, 0.0720, 0.0620 mg, and the limits of quantification of osthole, columbianadin and isoimperatorin were 0.2201, 0.2401, 0.2066 mg/mL. The solution had good stability and repeatability within 24 h. The recoveries of osthole, columbianadin and isoimperatorin were 102.26%, 99.89%, 103.28%, respectively. The established method is simple and easy to operate, which greatly reduces the cumbersome pretreatment of samples and has high extraction efficiency. Angelicae Pubescentis Radix (APR) is the dried root of Angelicae pubescentis maxim f. biserrata Shan et Yuan in China [1] . In addition to a long medical history in China, it is also distributed in Korea and Japan [2] . APR is pungent and mild, and has a good effect when treating rheumatic arthralgia. From the perspective of the basic theory of traditional Chinese medicine (TCM), dampness evil is recognized as one of the main pathogenic factors of the coronavirus disease 2019. APR as monarch drug or adjuvant can dispel pathogenic windage, clear dampness and activate yang qi, and has played an important role in the outbreak [3, 4] . Coumarin is a type of aromatic family of compounds with benzo-α-pyranone as the parent nucleus, which has been proved to be the compound with the most abundant content and the strongest biological activity [5] . In the 2020 edition of the Chinese pharmacopeia, coumarin components are regarded as one of the indexes to evaluate its quality. In modern pharmacological studies, coumarin has anti-problem of low concentration and strong interference (Table 1) . This method was used for the first time to quantitatively and qualitatively analyze the OS, CO and IS in APR. NS is the number of repeated samples. If NS is too small, insufficient scanning will result in poor accuracy and reproducibility; when NS is set high, the reproducibility is better and the signal-to-noise ratio can be improved to make the baseline of spectrogram more stable and flat, but at the same time the detection time will be prolonged. The process of the nucleus from the excited state to the equilibrium arrangement state is called the relaxation process, this process is a necessary condition for the generation of nuclear magnetic resonance phenomenon, the time required by it is called D1. In the 1 H-qNMR experiment, the appropriate D1 directly depends on the accuracy of quantitative results, and the suitable D1 can ensure the complete relaxation of the quantitative nucleus and the spectrum peak will not be saturated, which is conducive to the correct integration of the quantitative peak. If the D1 is too small, the quantitative results will be inaccurate and distorted, but D1 should not be set too high which would cause the extension of detection time. In this experiment, D1 and NS were set step by step to accumulate multiple experiments, and samples were taken from small to large according to D1 and NS. Then, the quantitative characteristic peaks of analytes and internal standard (pyazine) were integrated, and D1 and NS values whose integral area ratio no longer changed significantly were selected. Through the investigation of different D1 (1, 5, 15, 20, 25, 30, 40, 50, 70 , 90 and 100 s), the results showed that, with the gradual increase of D1, detection analysis time was also extended and the integral area was gradually decreased, and, when D1 was 15 s, the integral area no longer changed. After comprehensive consideration, we chose 15 s for D1. When NS was 16, 32, 64 and 128 times, the influence on the integral area was investigated. According to the analysis results, NS has no influence on the integral area, and with the increase of NS, the detection and analysis time were also extended, so NS was set at 16 times. The optimization of DLLME-SFO conditions were obtained by investigating the volume ratio of ultrapure water to the sample solution, the types, concentration and volume of extractant, different ionic strength, different pH, different speed and different extraction time. The enrichment factor (ER) is defined as the ratio of the total amount of the measured substance in the extraction phase to the initial amount of the measured substance in the sample phase. The specific calculation formula is as follows: C 0 and Cs are the concentration of the substance to be measured in the extraction solvent phase and the sample phase when the extraction reaches equilibrium. V 0 and Vs. are the volume of the extraction solvent phase and the sample phase respectively. In the experiment, graphene and graphene oxide were selected to investigate the effects on ER of OS, CO and IS within the range of 2.5-0.125 mg/mL, respectively. As can be seen from Figure 1 , the extraction effect of graphene was better; in this study, methanol was used to extract medicinal materials. Therefore, in order not to introduce other dispersion items to interfere with the extraction solution, methanol was used as a dispersant during the experiment. The optimization of DLLME-SFO conditions were obtained by investigating the volume ratio of ultrapure water to the sample solution, the types, concentration and volume of extractant, different ionic strength, different pH, different speed and different extraction time. The enrichment factor (ER) is defined as the ratio of the total amount of the measured substance in the extraction phase to the initial amount of the measured substance in the sample phase. The specific calculation formula is as follows: and Cs are the concentration of the substance to be measured in the extraction solvent phase and the sample phase when the extraction reaches equilibrium. V0 and Vs. are the volume of the extraction solvent phase and the sample phase respectively. In the experiment, graphene and graphene oxide were selected to investigate the effects on ER of OS, CO and IS within the range of 2.5-0.125 mg/mL, respectively. As can be seen from Figure 1 , the extraction effect of graphene was better; in this study, methanol was used to extract medicinal materials. Therefore, in order not to introduce other dispersion items to interfere with the extraction solution, methanol was used as a dispersant during the experiment. When the volume ratio of distilled water to the test solution was 4:6, 5:5 and 6:4, the solvent after extraction was a white, turbid liquid, and the turbidity degree was more pronounced with no large droplets appearing. When the volume ratio was 7:3, the solvent after extraction was still a white, turbid liquid, although the turbidity degree was relatively low and there was also no large droplets. When the volume ratio was 8:2 and 9:1, there was no turbidity and droplets appeared in the extracted solution. ER was calculated and compared according to the experimental results. Finally when the volume ratio of distilled water to the test solution was 9:1, the extracted solution had no turbidity and the extraction rate was the highest. When the volume ratio of distilled water to the test solution was 4:6, 5:5 and 6:4, the solvent after extraction was a white, turbid liquid, and the turbidity degree was more pronounced with no large droplets appearing. When the volume ratio was 7:3, the solvent after extraction was still a white, turbid liquid, although the turbidity degree was relatively low and there was also no large droplets. When the volume ratio was 8:2 and 9:1, there was no turbidity and droplets appeared in the extracted solution. ER was calculated and compared according to the experimental results. Finally when the volume ratio of distilled water to the test solution was 9:1, the extracted solution had no turbidity and the extraction rate was the highest. The study investigated the influence of the concentration of graphene in 1-dodecyl alcohol at 2.5-0.25 mg/mL on ER. It can be seen from the Figure 2 that when the concentration of graphene in 1-dodecyl alcohol was 0.50 mg/mL, the ER of OS, CO and IS were the highest. The study investigated the influence of the concentration of graphene in 1-dodecyl alcohol at 2.5-0.25 mg/mL on ER. It can be seen from the Figure 2 that when the concentration of graphene in 1-dodecyl alcohol was 0.50 mg/mL, the ER of OS, CO and IS were the highest. In order to evaluate the effect of the volume of the extractant on ER, different volumes of graphene/1-dodecyl alcohol (40, 50, 60, 70, 80 and 90 μL) were selected for investigation. As shown in the Figure 3 , the extraction efficiency was the highest when the volume was 80 μL. The lactones in coumarin components are prone to ring opening and hydrolysis under alkaline conditions. Therefore, the effect of pH on ER at 2-7 was analyzed by adding 0.40 mol/L HCl and 0.40 mol/L NaOH. When the pH of the solution was 5, the ER of OS, CO and IS were the highest, at 16.39%, 19.62% and 11.11%, respectively. The detailed results are shown in Figure 4 . In order to evaluate the effect of the volume of the extractant on ER, different volumes of graphene/1-dodecyl alcohol (40, 50, 60, 70, 80 and 90 µL) were selected for investigation. As shown in the Figure 3 , the extraction efficiency was the highest when the volume was 80 µL. The study investigated the influence of the concentration of graphene in 1-dod alcohol at 2.5-0.25 mg/mL on ER. It can be seen from the Figure 2 that when the con tration of graphene in 1-dodecyl alcohol was 0.50 mg/mL, the ER of OS, CO and IS w the highest. In order to evaluate the effect of the volume of the extractant on ER, different umes of graphene/1-dodecyl alcohol (40, 50, 60, 70, 80 and 90 μL) were selected fo vestigation. As shown in the Figure 3 , the extraction efficiency was the highest when volume was 80 μL. The lactones in coumarin components are prone to ring opening and hydro under alkaline conditions. Therefore, the effect of pH on ER at 2-7 was analyzed adding 0.40 mol/L HCl and 0.40 mol/L NaOH. When the pH of the solution was 5, th of OS, CO and IS were the highest, at 16.39%, 19.62% and 11.11%, respectively. The tailed results are shown in Figure 4 . The lactones in coumarin components are prone to ring opening and hydrolysis under alkaline conditions. Therefore, the effect of pH on ER at 2-7 was analyzed by adding 0.40 mol/L HCl and 0.40 mol/L NaOH. When the pH of the solution was 5, the ER of OS, CO and IS were the highest, at 16.39%, 19.62% and 11.11%, respectively. The detailed results are shown in Figure 4 . The effects of different ionic strength (0%, 1%, 2%, 2.5%, 5%, 8% and 10% extraction efficiency were investigated by adding different concentrations of N the extraction solution. The results showed that when NaCl concentration was ER% of OS, CO and IS was the best. ( Figure 5 ) The effect of speed on extraction efficiency was investigated by setting the s 500, 600, 700, 800, 900, 1000, 1200 and 1400 rpm. The experimental results show when the speed was greater than or equal to 1000 rpm, the extracted solution pr white turbidity without droplets, and as can be seen from Figure 6 , when th reached 800 rpm, the ER of the target analytes gradually tended to be stable and the highest point, so 800 rpm was chosen as the speed. The effects of different ionic strength (0%, 1%, 2%, 2.5%, 5%, 8% and 10%) on the extraction efficiency were investigated by adding different concentrations of NaCl into the extraction solution. The results showed that when NaCl concentration was 5%, the ER% of OS, CO and IS was the best. ( The effects of different ionic strength (0%, 1%, 2%, 2.5%, 5%, 8% and 10%) o extraction efficiency were investigated by adding different concentrations of NaC the extraction solution. The results showed that when NaCl concentration was 5% ER% of OS, CO and IS was the best. ( Figure 5 ) The effect of speed on extraction efficiency was investigated by setting the spe 500, 600, 700, 800, 900, 1000, 1200 and 1400 rpm. The experimental results showed when the speed was greater than or equal to 1000 rpm, the extracted solution pres white turbidity without droplets, and as can be seen from Figure 6 , when the s reached 800 rpm, the ER of the target analytes gradually tended to be stable and rea the highest point, so 800 rpm was chosen as the speed. The effect of speed on extraction efficiency was investigated by setting the speed to 500, 600, 700, 800, 900, 1000, 1200 and 1400 rpm. The experimental results showed that, when the speed was greater than or equal to 1000 rpm, the extracted solution presented white turbidity without droplets, and as can be seen from Figure 6 , when the speed reached 800 rpm, the ER of the target analytes gradually tended to be stable and reached the highest point, so 800 rpm was chosen as the speed. Molecules 2021, 26, x FOR PEER REVIEW Figure 6 . The effects of different speed on ER. The extraction time was the period from the addition of the magnetic rotor in extraction solution to the end of extraction. The effects of different extraction time 20, 30, 40 and 50 min) on ER were investigated. As can be seen from the Figure 7 , the extraction time was 10-20 min, the ER of the target analyte gradually increase reached its maximum at 20 min. When the extraction time was more than 20 mi decreased with the extension of the extraction time. Therefore, 20 min was selected extraction time in this study. The appropriate amount of OS, CO and IS was precisely weighed and prepare a mixed solution, then diluted to eight different concentrations. The linear range o CO and IS were all 0.0455-2.2727 mg/mL, and R 2 were 0.9994, 0.9994 and 0.9995, re tively. The results showed that there was a good linear relationship between the in area and the concentration ( Table 2 ). Limit of detection (LOD) is the smallest amount that the method can reliably to determine presence or absence of an analyte. Limit of quantification (LOQ) smallest amount that the method can reliably measure quantitatively to an accep level. Using the equation XB + kσB, where XB and σB are the mean and the standard ation of blank measurements, and k is the numerical factor determining the confi The extraction time was the period from the addition of the magnetic rotor into the extraction solution to the end of extraction. The effects of different extraction times (10, 20, 30, 40 and 50 min) on ER were investigated. As can be seen from the Figure 7 , when the extraction time was 10-20 min, the ER of the target analyte gradually increased and reached its maximum at 20 min. When the extraction time was more than 20 min, ER decreased with the extension of the extraction time. Therefore, 20 min was selected as the extraction time in this study. The appropriate amount of OS, CO and IS was precisely weighed and prepa a mixed solution, then diluted to eight different concentrations. The linear range CO and IS were all 0.0455-2.2727 mg/mL, and R 2 were 0.9994, 0.9994 and 0.9995, tively. The results showed that there was a good linear relationship between the area and the concentration ( Table 2 ). Limit of detection (LOD) is the smallest amount that the method can reliabl to determine presence or absence of an analyte. Limit of quantification (LOQ smallest amount that the method can reliably measure quantitatively to an acc level. Using the equation XB + kσB, where XB and σB are the mean and the standar ation of blank measurements, and k is the numerical factor determining the con The appropriate amount of OS, CO and IS was precisely weighed and prepared into a mixed solution, then diluted to eight different concentrations. The linear range of OS, CO and IS were all 0.0455-2.2727 mg/mL, and R 2 were 0.9994, 0.9994 and 0.9995, respectively. The results showed that there was a good linear relationship between the internal area and the concentration ( Table 2 ). Limit of detection (LOD) is the smallest amount that the method can reliably detect to determine presence or absence of an analyte. Limit of quantification (LOQ) is the smallest amount that the method can reliably measure quantitatively to an acceptable level. Using the equation X B + kσ B , where X B and σ B are the mean and the standard deviation of blank measurements, and k is the numerical factor determining the confidence level, LOD: k = 3, LOQ: k = 10 [46] . The LOD and LOQ of OS, CO and IS were analyzed as shown in the Table 2 below. High, medium and low concentrations were selected from the mixed reference materials and each concentration was measured in parallel for three times to determine precision. The RSD of OS, CO and IS were 1.10%, 1.07% and 0.90%, respectively, indicating that the precision of the instrument was good. In order to monitor the stability of the extracted sample solution, the same batch of medicinal materials should be measured under the same experimental conditions at 0, 2, 4, 8, 12 and 24 h. The RSD of OS, CO and IS were 1.56%, 1.04% and 1.54%, respectively, indicating that the samples were relatively stable within 24 h. The same batch of samples was repeated in order to investigate the repeatability of the established method, the RSD of OS, CO and IS were 2.56%, 2.13% and 3.70%, respectively. One milligram of APR powder with known content was precisely weighed, and an appropriate amount of reference substance was added. The powder was for detection and analysis which was extracted according to 2.1, and then extracted according to 2.2. The experimental results were shown in Table 3 . The established method was used to determine OS, CO and IS of APR from different producing areas. The detailed results were shown in Table 4 . The quantitative signal of OS was at δ6.25-δ6.26 ppm, CO was at δ6.83-δ6.85 ppm, and IS was at δ6.31-δ6.32 ppm. APR was crushed and sifted, and 5 g of medicinal powder was precisely weighed and added with 50 mL methanol, which was extracted by ultrasonic (40 °C, 40 min), methanol was used to make up the missing weight, the extraction was filtered by decompression and stored at 4 °C in the dark for later use. Graphene (2.5 mg) was precisely weighed and placed in a 10 mL volumetric flask. 1-dodecyl alcohol was added and ultrasonic was used for 1 h to make graphene completely dissolved in 1-dodecyl alcohol. After standing the solution was not stratified or precipitated, then graphene/1-dodecyl alcohol extractant was obtained, and the appropriate amount of the prepared extractant was absorbed and diluted to 0.5 mg/mL. The conical flask was fixed on the magnetic agitator, 9 mL ultrapure water and 1 mL test solution, 80 μL graphene/1-dodecyl alcohol (5 mg/mL) and 100 μL NaCl (5%) solution were added respectively, and the pH of the solution was adjusted to 5. Magnetic rotor was introduced in the conical flask, then extracted after 20 min (800 rpm, 40 °C) and let stand for 5 min, the conical flask was gently turned to form a large droplet, which was quickly frozen at −20 °C for 10 min. After solidification, the conical flask was removed with a small spoon and melted at room temperature, the accumulated phase was extracted with microinjection needle, besides the volume of accumulated phase was recorded and injected into the nuclear magnetic tube. Then 450 μL DMSO-d6 and 25 μL pyrazine (10 mg/mL) were added. The specific experimental operation process was shown in the Figure 9 . The 1 H-NMR spectrum of APR was shown in Figure 10 . The preconcentration factor was obtained by dividing the concentration after extraction by the concentration before extraction. The preconcentration factors for OS, CO and IS were 270.01%, 248.30% and 268.29%, respectively. Although the preconcentration factors were low, they were useful for the QNMR method. It was found that the impurity peaks in the 1 H-NMR spectrum were less and the separation degree was better after extraction ( Figure 11 ). APR was crushed and sifted, and 5 g of medicinal powder was precisely weighed and added with 50 mL methanol, which was extracted by ultrasonic (40 • C, 40 min), methanol was used to make up the missing weight, the extraction was filtered by decompression and stored at 4 • C in the dark for later use. Graphene (2.5 mg) was precisely weighed and placed in a 10 mL volumetric flask. 1-dodecyl alcohol was added and ultrasonic was used for 1 h to make graphene completely dissolved in 1-dodecyl alcohol. After standing the solution was not stratified or precipitated, then graphene/1-dodecyl alcohol extractant was obtained, and the appropriate amount of the prepared extractant was absorbed and diluted to 0.5 mg/mL. The conical flask was fixed on the magnetic agitator, 9 mL ultrapure water and 1 mL test solution, 80 µL graphene/1dodecyl alcohol (5 mg/mL) and 100 µL NaCl (5%) solution were added respectively, and the pH of the solution was adjusted to 5. Magnetic rotor was introduced in the conical flask, then extracted after 20 min (800 rpm, 40 • C) and let stand for 5 min, the conical flask was gently turned to form a large droplet, which was quickly frozen at −20 • C for 10 min. After solidification, the conical flask was removed with a small spoon and melted at room temperature, the accumulated phase was extracted with microinjection needle, besides the volume of accumulated phase was recorded and injected into the nuclear magnetic tube. Then 450 µL DMSO-d 6 and 25 µL pyrazine (10 mg/mL) were added. The specific experimental operation process was shown in the Figure 9 . The 1 H-NMR spectrum of APR was shown in Figure 10 . The preconcentration factor was obtained by dividing the concentration after extraction by the concentration before extraction. The preconcentration factors for OS, CO and IS were 270.01%, 248.30% and 268.29%, respectively. Although the preconcentration factors were low, they were useful for the QNMR method. It was found that the impurity peaks in the 1 H-NMR spectrum were less and the separation degree was better after extraction ( Figure 11 ). mg/mL) were added. The specific experimental operation process was shown in the Figure 9 . The 1 H-NMR spectrum of APR was shown in Figure 10 . The preconcentration factor was obtained by dividing the concentration after extraction by the concentration before extraction. The preconcentration factors for OS, CO and IS were 270.01%, 248.30% and 268.29%, respectively. Although the preconcentration factors were low, they were useful for the QNMR method. It was found that the impurity peaks in the 1 H-NMR spectrum were less and the separation degree was better after extraction ( Figure 11 ). All NMR spectra were recorded on a Bruker Advance III 600 MHz spectrometer. The spectrometer was operating at 600.10 MHz for 1H resonances, using a multinuclear broadband 5 mm probe. DMSO was chosen as deuterated solvent because of its superior solubility, preventing the solvent peak from overlapping with other peaks. Pyrazine was selected as the internal standard. Usual procedures for locking and shimming were conducted and followed by a careful tuning and matching adjustment for each sample. The pulse sequence was zg30, pulse width (P1) of 10.00 μs, test temperature (TE) of 295.6 All NMR spectra were recorded on a Bruker Advance III 600 MHz spectrometer. The spectrometer was operating at 600.10 MHz for 1H resonances, using a multinuclear broadband 5 mm probe. DMSO was chosen as deuterated solvent because of its superior solubility, preventing the solvent peak from overlapping with other peaks. Pyrazine was selected as the internal standard. Usual procedures for locking and shimming were conducted and followed by a careful tuning and matching adjustment for each sample. All NMR spectra were recorded on a Bruker Advance III 600 MHz spectrometer. The spectrometer was operating at 600.10 MHz for 1H resonances, using a multinuclear broadband 5 mm probe. DMSO was chosen as deuterated solvent because of its superior solubility, preventing the solvent peak from overlapping with other peaks. Pyrazine was selected as the internal standard. Usual procedures for locking and shimming were conducted and followed by a careful tuning and matching adjustment for each sample. The pulse sequence was zg30, pulse width (P1) of 10.00 µs, test temperature (TE) of 295.6 K, spectrum width (SWH) of 11904.762 Hz, acquisition time (AQ) of 2.75 s, relaxation delay time (D1) of 1 s, scan times (NS) of 32 times. The purpose of this study was to establish DLLME-SFO method, and graphene/1dodecyl alcohol as extractant combined with 1 H-qNMR for the first time to analyze OS, CO and IS in APR qualitatively and quantitatively. The extraction conditions were all optimized to obtain the best extraction method. The accuracy, stability and recovery of the established method were good after the methodology verification. Compared with other conventional methods, this method is more environmentally friendly, and has a high extraction efficiency, simple operation and good precision. The introduction of nanomaterials enhanced the adsorption and extraction, which help to solve the problem of low sensitivity and strong interference. It is worth discussing and explore for the extraction of effective components of TCM. It is hoped that this method can be used in the extraction of some valuable and rare effective ingredients in TCM in the future, which have special curative effect for some hard to treat diseases, such as cancer, HIV and so on. The data presented in this study are available on request from the corresponding author. magnetic resonance spectrometer (Bruker Advance III 600-MHz PS-30 ultrasonic cleaning machine (Shenzhen Dekang Science and Technology Co., Ltd HX203 telectronic balance JFSD-100 disintegrator (Shandong Jingcheng Medical Equipment Manufacturing Co., Ltd isoimperatorin (Lot 18062202, 98%) and columbianadin (98%) were purchased from Chengdu Pufei De Biotech Co HCl (≥96%) and NaOH (≥96%) were all bought from Tianjin Damao Chemical Reagent Factory Chinese Pharmacopoeia Commission. Pharmacopoeia of People's Republic of China Traditional Chinese medicine of Angelicae pubescentis radix: A review of phytochemistry, pharmacology and pharmacokinetics Tracing sources of prescriptions for treating dampness in initial stage of Corona Virus disease 2019 Enlightenment of "lung wind" in Nei Jing on the treatment of COVID-19 Simultaneous assessment of absorption characteristics of coumarins from Angelicae Pubescentis Radix: In vitro transport across Caco-2 cell and in vivo pharmacokinetics in rats after oral administration Anti-inflammatory and analgesic activity of r.a.p. (Radix Angelicae Pubescentis) ethanol extracts Analgesic effect of coumarins from Radix angelicae pubescentis is mediated by inflammatory factors and TRPV1 in a spared nerve injury model of neuropathic pain The pharmacokinetics, bioavailability and excretion of columbianetin acetate and its metabolite columbianetin were analysed in rat plasma by LC-MS/MS after administration of columbianetin acetate and Angelicae pubescentis radix extract Current developments of coumarin-based anti-cancer agents in medicinal chemistry EGFR/cell membrane chromatography-online-high performance liquid chromatography/mass spectrometry method for screening EGFR antagonists from Radix Angelicae Pubescentis Determination of ppb-level phenol index using in-syringe dispersive liquid-liquid microextraction and liquid waveguide capillary cell spectrophotometry A single-valve sequential injection manifold (SV-SIA) for automation of air-assisted liquid-phase microextraction: Stopped flow spectrophotometric determination of chromium(vi) Analysis of triazine herbicides using an up-and-down-shaker-assisted dispersive liquidliquid microextraction coupled with gas chromatography-mass spectrometry In-syringe magnetic stirring assisted dispersive liquid-liquid micro-extraction with solvent washing for fully automated determination of cationic surfactants An automatic, vigorous-injection assisted dispersive liquid-liquid microextraction technique for stopped-flow spectrophotometric detection of boron Dispersive liquid-liquid microextraction method based on solidification of floating organic drop combined with gas chromatography with electron-capture or mass spectrometry detection Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection Determination of organic compounds in water using dispersive liquid-liquid microextraction Development of dispersive liquid-liquid microextraction combined with gas chromatography-mass spectrometry as a simple, rapid and highly sensitive method for the determination of phthalate esters in water samples Developments of dispersive liquid-liquid microextraction technique. Chin A new liquid-phase microextraction method based on solidification of floating organic drop Determination of ultra traces of lead in water samples after combined solid-phase extraction-dispersive liquid-liquid microextraction by graphite furnace atomic absorption spectrometry Efficient and selective extraction and determination of ultra trace amounts of Hg2+ using solid phase extraction combined with ion pair based surfactant-assisted dispersive liquid-liquid microextraction Application of dispersive liquid-liquid microextraction based on solidification of floating organic drop for the determination of extractables from pharmaceutical packaging materials Trace determination of heavy metals in farmed trout fish using dispersive liquid-liquid microextraction based on solidification of floating organic drop and graphite furnace atomic absorption spectrometry Speciation of inorganic arsenic species and total inorganic arsenic in rice using microwave-assisted dispersive liquid-liquid micro-extraction and electrothermal atomic absorption spectrometry A novel method for the high preconcentration of trace amounts of the aflatoxins in pistachios by dispersive liquid-liquid microextraction after solid-phase extraction Sensitive determination of atorvastatin in human plasma by dispersive liquid-liquid microextraction and solidification of floating organic drop followed by high-performance liquid chromatography Determination of budesonide and sulfasalazine in water and wastewater samples using DLLME-SFO-HPLC-UV Method Dispersive liquid-liquid microextraction followed by highperformance liquid chromatography-ultraviolet detection to determination of opium alkaloids in human plasma Rapid extraction and determination of amphetamines in human urine samples using dispersive liquid-liquid microextraction and solidification of floating organic drop followed by high performance liquid chromatography Ultrasound-assisted dispersive liquid-liquid microextraction based on the solidification of a floating organic droplet followed by gas chromatography for the determination of eight pyrethroid pesticides in tea samples Dispersive liquid-liquid microextraction based on the solidification of floating organic droplet for the determination of polychlorinated biphenyls in aqueous samples Dispersive liquid-liquid microextraction method based on solidification of floating organic droplet for the determination of triazine herbicides in water and sugarcane samples Dispersive liquid-liquid microextraction for chemical speciation and determination of ultra-trace concentrations of metal ions A simple and rapid new dispersive liquid-liquid microextraction based on solidification of floating organic drop combined with inductively coupled plasma-optical emission spectrometry for preconcentration and determination of aluminium in water samples Determination of cadmium and lead at sub-ppt level in soft drinks: An efficient combination between dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry The rise of graphene A roadmap for graphene Status and Prospects Extraction of carbamate pesticides in fruit samples by graphene reinforced hollow fibre liquid microextraction followed by high performance liquid chromatographic detection Graphene Reinforced Hollow Fiber Liquid Phase Microextraction for the Enrichment of some Phenylurea Residues in Milk Sample Graphene/polydopamine-modified polytetrafluoroethylene microtube for the sensitive determination of three active components in Fructus Psoraleaeby online solid-phase microextraction with high-performance liquid chromatography The Establishment of Novel Dispersive Liquid Phase Microextraction Methods and Their Application for Analysis of Cinnamic Acid Derivatives in Traditional Chinese Medicines The Use of 1H-qNMR Method for Simultaneous Determination of Osthol, Columbianadin, and Isoimperatorin in Angelicae Pubescentis Radix A validated 1H qNMR method for direct and simultaneous quantification of esculin, fraxin and (−)-epicatechin in Hippocastani cortex There are no conflict of interest to declare.Sample Availability: Samples of the compounds are available from the authors.