key: cord-1031065-h8zizscy authors: Cantoni, Diego; Mayora-Neto, Martin; Temperton, Nigel title: The Role of Pseudotype Neutralisation Assays in Understanding SARS CoV-2 date: 2021-02-12 journal: Oxf Open Immunol DOI: 10.1093/oxfimm/iqab005 sha: 5b2b832734869d9becd5bcbec4413ed6d4a29c2b doc_id: 1031065 cord_uid: h8zizscy Neutralisation assays are crucial tools to quantify the presence of functional neutralising antibodies in serum samples. Since the SARS-CoV-2 virus (the causative agent of COVID-19) is designated as a category 3 biosafety level pathogen, pseudotyped viruses bearing the SARS-CoV-2 spike protein permit extensive and widespread serum/plasma screening in a BSL 2 laboratory. These assays can be used to assess viral tropism, vaccine immunogenicity, efficacy of antiviral compounds (incl. therapeutic mAbs) and serosurveillance studies. In this article, we highlight approaches to SARS-CoV-2 viral pseudotyping, its practicality, and utility in increasing our understanding of neutralising antibodies against SARS-CoV-2. Typical PV generation and titration can be carried out within a two-week timeframe and may be readily scaled up to produce large volumes of virus. Storage is recommended at -80°C, or -20°C for a short period of time with little loss of titre, and freeze thaws are preferably kept to a minimum, though some pseudotyped viruses may not lose much infectivity even after three freeze thaw cycles 8, 9 . Various methodologies are publicly available that describe in detail the steps required to generate SARS-CoV-2 PVs 9-12 . The PV neutralization assay is typically carried out in 96-well plates, whereby serum samples are serially diluted and then incubated with a fixed amount of SARS-CoV-2 PVs to allow any neutralising antibodies to bind to the Spike (S). Cells naturally expressing the ACE2 receptor and the transmembrane serine protease 2 (TMPRSS2) are then added to the plates and incubated for 48-72 hours otherwise co-transfection of ACE2 and TMPRSS2 plasmids can be carried out to render cells such as HEK 293T, and HeLa permissive to infection. If the PVs contain a luciferase reporter, then cells are lysed, and luciferase reporter expression is quantified using a luminometer. For GFP-based assays the GFP positive cells are counted at each dilution to determine the percentage of neutralisation, using a fluorescent microscope or a flow cytometer. The benefits of using a SARS-CoV-2 PV aside from the enhanced biosafety, is that PV neutralization assay screening is highly serum sparing, with as little as 2µL per sample required, and that the assay itself is based on the spike S protein being the only CoV antigen in the system, therefore validating antibody-receptor binding and neutralisation. Whilst it is true that ELISA assays can be used to detect presence of antibodies in response to viral infection, the system itself specifically detects antibody binding to the viral protein, but it does not measure whether this interaction results in neutralisation, though recently next-generation kits have been developed to provide that level of information [13] [14] [15] . Typically, an initial screening would start with ELISA to detect serum samples with antibodies, followed by a PV neutralisation assay (PVNA), which would then provide information on antibody neutralisation. PVNAs have been shown to correlate broadly with wild-type virus neutralisation assays 2,12,16,17 . Furthermore, generating mutant spike protein can be done readily by site-directed mutagenesis, allowing to produce SARS-CoV-2 PVs bearing mutants that may be in circulation (such as the variants of concern for SARS-CoV-2), or to evaluate the importance of specific amino acids on receptor binding and entry [18] [19] [20] . The relative ease and short time frame involved in generating single-point mutations allows for the rapid screening of key sites and highlights the malleability of pseudotyped viruses and their use for investigating variants in circulation [21] [22] [23] . It is for these reasons that PVNA are considered to be highly valuable tools in investigating efficacy of antibody responses to viruses. Many research reports have incorporated PVNA to detect the presence of neutralising antibodies against SARS-CoV-2. The verification of the first human monoclonal antibody that neutralises both SARS-CoV-1 and SARS-CoV-2, 47D11, was assessed using PVNAs 24 . This particular study was illuminating as 47D11 did not prevent Spike binding to ACE2, suggesting an unknown mechanism for neutralisation. Nevertheless, strong cross-neutralisation activity was detected in both PVNAs and wild-type virus assays, even though 47D11 does not compromise SARS-CoV-2 spike-ACE2 receptor binding. This highlights the strengths of using PVNA, as it can detect neutralising activity of antibodies that do not necessary prevent virus-host receptor binding. In another study, authors examined plasma samples from patients that had previously travelled from Wuhan to Shenzhen, China, during the outbreak using pseudotyped HIV particles with either SARS-CoV-1, SARS-CoV-2, or MERS-CoV 25 . Some of the patients in this study comprised a family cluster, including the first documented case of human to human transmission in Shenzhen 26 . Neutralising antibody levels varied between patients, and there was little cross-neutralisation between the different PVs, suggesting that the RBDs between SARS-CoV-1 and MERS-CoV are immunologically distinct. The authors had additionally compared the antibody neutralisation results using wild-type virus, which was consistent with the PV assay data. A study conducted early during the outbreak at a children's hospital in Seattle, USA had used PV to screen for neutralising antibodies 27 . Overall, ten seropositive samples had SARS-CoV-2 neutralising antibodies, and seven of the seropositive samples were collected from six children who had never tested positive for SARS-CoV-2. We found this to be a strong example of how effective PVNAs can be as a serological screening tool to detect individuals carrying neutralising antibodies to SARS-CoV-2 despite testing negative by PCR. This approach of using PVs as a screening tool can be scaled up as part of larger serological surveillance studies 28 . PVNA can also be used to measure neutralising antibody responses in patients with varying severity of disease 29, 30 . Sera from recovered COVID-19 patients from a hospital in Guangzhou, China categorised as severe, moderate, and mild, were subjected to PVNAs 31 . Within the study, asymptomatic sera from patients from Chongqing, China, were also included. The results showed a correlation between serum neutralisation capacity and disease severity, whereby high severity had most neutralising activity. The asymptomatic samples however showed no ability to neutralise PV activity, despite detection of RBD-binding antibodies by ELISA. The pseudotyped nAb assay results were then confirmed with wild-type virus experiments. This highlights the strengths of using PVs as a surrogate virus for neutralisation assays. Studies have also incorporated PVNAs as part of longitudinal studies on antibody responses. One study in the UK investigated antibody responses in COVID-19 positive patients that were categorised by a severity score ranging from 0; asymptomatic, to 5; requirement for extracorporeal membrane oxygenation 32 . The pseudotyped nAb assays was able to reveal that disease severity enhanced the magnitude of neutralising antibody response and the authors were able to monitor the neutralisation response in samples collected over 50 days post onset of symptoms. Similar longitudinal studies also reported comparable findings using either PVNAs or wild-type virus, which provide insight into the kinetics of the immune response, starting at onset of infection with follow up bleeds over time 33, 34 . Due to the urgent need for a suite of effective vaccines to protect individuals globally against SARS-CoV-2, significant developments are being made, and many published reports have also incorporated PVNA as part of the toolbox to investigate antibody responses post immunisation in both human and animal models 35, 36 . For example, in the phase 1 trial of the mRNA-1273 candidate vaccine, PVNAs were employed before and after each round of vaccination 37 . PVNAs revealed modest antibody responses after the first round of vaccination, followed by a robust antibody response after the second round of vaccination. Similarly, another study investigating humoral immune responses in mice after initial immunization using nucleoside-modified mRNA vaccines observed efficient PV neutralisation from the antibodies in the sera 38 . Another investigation developed a prototype DNA vaccine, which was tested in rhesus macaques. The PVNAs revealed strong inhibition by the antibodies in the sera, similar to the levels observed in patients that recover from SARS-CoV-2, which was verified by ELISA and wild-type virus 39 . An investigation to assess effectiveness of the immune response after a second infection in rhesus macaques had used both PVNAs and wild-type viral neutralisation assays, of which both revealed that the second challenge resulted in significant decrease of viral load compared to the initial viral infection 40 . Ongoing studies are aiming to use PVNAs to address a key question; what are the immune correlates of protection? Currently the World Health Organisation and National Institute for Biological Standards and Control (NIBSC) have developed a serological standard in order to allow studies to report antibody responses in international units, which would provide valuable insight into what constitutes a protective immune response in individuals 41 . In conclusion, we believe that pseudotyped viruses are a simple and valuable tool to investigate the presence of neutralising antibodies in serum samples from animal models and humans. These assays can be scaled to allow high-throughput screening and are safe to carry out in BSL-2 laboratories. Data availability: There is no data associated with this review article Funding: The Temperton group is funded by the Wellcome Trust (GB-CHC-210183), the MRC (MC_PC_19060) and MRC/NIHR (MC_PC_20016) Viral infection neutralization tests: A focus on severe acute respiratory syndrome-coronavirus-2 with implications for convalescent plasma therapy Measuring SARS-CoV-2 neutralizing antibody activity using pseudotyped and chimeric viruses Generation of VSV pseudotypes using recombinant ΔG-VSV for studies on virus entry, identification of entry inhibitors, and immune responses to vaccines Production of pseudotyped particles to study highly pathogenic coronaviruses in a biosafety level 2 setting Current status on the development of pseudoviruses for enveloped viruses Detection of replication-competent and pseudotyped human immunodeficiency virus with a sensitive cell line on the basis of activation of an integrated beta-galactosidase gene A neutralization test for specific detection of Nipah virus antibodies using pseudotyped vesicular stomatitis virus expressing green fluorescent protein Multiplex evaluation of influenza neutralizing antibodies with potential https://mc.manuscriptcentral.com/oxfimm applicability to in-field serological studies Production, titration, neutralisation and storage of SARS-CoV-2 lentiviral pseudotypes Protocol and reagents for pseudotyping lentiviral particles with SARS-CoV-2 spike protein for neutralization assays Establishment and validation of a pseudovirus neutralization assay for SARS-CoV-2 Characterisation of SARS-CoV-2 Lentiviral Pseudotypes and Correlation between Pseudotype-Based Neutralisation Assays and Live Virus-Based Micro Neutralisation Assays A SARS-CoV-2 surrogate virus neutralization test based on antibodymediated blockage of ACE2-spike protein-protein interaction Virus-free and live-cell visualizing SARS-CoV-2 cell entry for studies of neutralising antibodies and compound inhibitors Rapid quantitative screening assay for SARS-CoV-2 neutralizing antibodies using HiBiT-tagged virus-like particles High degree of correlation between Ebola virus BSL-4 neutralization assays and pseudotyped VSV BSL-2 fluorescence reduction neutralization test Development and effectiveness of Pseudotyped SARS-CoV-2 system as determined by neutralizing efficiency and entry inhibition test in vitro Optimized Pseudotyping Conditions for the SARS-COV-2 Spike Glycoprotein Combined Point-of-Care Nucleic Acid and Antibody Testing for SARS-CoV-2 following Emergence of D614G Spike Variant The Impact of Mutations in SARS-CoV-2 Spike on Viral Infectivity and Antigenicity Complete mapping of mutations to the SARS-CoV-2 spike receptorbinding domain that escape antibody recognition Neutralization of SARS-CoV-2 lineage B.1.1.7 pseudovirus by BNT162b2 vaccine-elicited human sera Escape from neutralizing antibodies 1 by SARS-CoV-2 spike protein variants A human monoclonal antibody blocking SARS-CoV-2 infection Human neutralizing antibodies elicited by SARS-CoV-2 infection A familial cluster of pneumonia associated with the 2019 novel coronavirus indicating person-to-person transmission: a study of a family cluster Serological identification of SARS-CoV-2 infections among children visiting a hospital during the initial Seattle outbreak Detection of neutralising antibodies to SARS-CoV-2 to determine population exposure in Scottish blood donors between Anti-spike, Anti-nucleocapsid and Neutralizing Antibodies in SARS-CoV-2 Inpatients and Asymptomatic Individuals Discordant neutralizing antibody and T cell responses in asymptomatic and mild SARS-CoV-2 infection Disease severity dictates SARS-CoV-2-specific neutralizing antibody responses in COVID-19 Longitudinal observation and decline of neutralizing antibody responses in the three months following SARS-CoV-2 infection in humans Longitudinal dynamics of the neutralizing antibody response to SARS-CoV-2 infection Evaluating the Association of Clinical Characteristics with Neutralizing Antibody Levels in Patients Who Have Recovered from Mild COVID-19 in Measuring immunity to SARS-CoV-2 infection: comparing assays and animal models Safety and immunogenicity of the ChAdOx1 nCoV-19 vaccine against SARS-CoV-2: a preliminary report of a phase 1/2, single-blind, randomised controlled trial An mRNA Vaccine against SARS-CoV-2 -Preliminary Report A Single Immunization with Nucleoside-Modified mRNA Vaccines Elicits Strong Cellular and Humoral Immune Responses against SARS-CoV-2 in Mice DNA vaccine protection against SARS-CoV-2 in rhesus macaques SARS-CoV-2 infection protects against rechallenge in rhesus macaques Establishment of the WHO International Standard and Reference Panel for anti-SARS-CoV-2 antibody