key: cord-1029276-eop8r7vf authors: Shui, Lili; Yang, Binbin; Tang, Hong; Luo, Yan; Hu, Shuang; Zhong, Xiaoqing; Duan, Jun title: Physiological Effects of Surgical and N95 Masks During Exercise in the Covid-19 Era date: 2022-02-27 journal: Am J Med Sci DOI: 10.1016/j.amjms.2022.02.006 sha: 4998fd82b342140df887f0b53c02cb0e56c6bec9 doc_id: 1029276 cord_uid: eop8r7vf Background: During the COVID-19 pandemic, studies of the physiological effects of masking during exercise have been rare. Methods: Twelve healthcare workers performed a cardiopulmonary exercise test while wearing a surgical mask, an N95 mask, or no mask. Variables were collected at rest, warm-up, anaerobic threshold, and maximal exercise. Results: From rest to maximal exercise, both the surgical and N95 masks decreased inspiratory flow, minute ventilation, and prolonged inspiratory time compared to the no mask condition. Oxygen uptake (VO(2)) and oxygen pulse (VO(2)/HR) decreased at rest, warm-up, and maximal exercise in both the surgical and N95 mask conditions (vs. no mask). At the anaerobic threshold, the surgical mask also led to a reduction of oxygen uptake and oxygen pulse compared to no mask. The maximal oxygen uptake (VO(2)% predicted) also decreased in both the surgical and N95 mask conditions. In addition, the severity of dyspnea increased, and exercise time decreased for both surgical and N95 masks. Compared to no mask, wearing an N95 mask led to lower breathing frequency and lower ventilation efficacy (assessed by VE/VCO(2) and VE/VO(2)) from rest to maximal exercise (all p < 0.05 for trend). Wearing an N95 also led to retention of carbon dioxide (p < 0.05 for trend). Conclusions: Wearing a surgical mask leads to a somewhat negative impact on cardiopulmonary function, and this effect is more serious with an N95 mask. Attention should be paid to exercise while wearing surgical or N95 masks. Background: During the COVID-19 pandemic, studies of the physiological effects of masking during exercise have been rare. Methods: Twelve healthcare workers performed a cardiopulmonary exercise test while wearing a surgical mask, an N95 mask, or no mask. Variables were collected at rest, warm-up, anaerobic threshold, and maximal exercise. Results: From rest to maximal exercise, both the surgical and N95 masks decreased inspiratory flow, minute ventilation, and prolonged inspiratory time compared to the no mask condition. Oxygen uptake (VO 2 ) and oxygen pulse (VO 2 /HR) decreased at rest, warm-up, and maximal exercise in both the surgical and N95 mask conditions (vs. no mask). At the anaerobic threshold, the surgical mask also led to a reduction of oxygen uptake and oxygen pulse compared to no mask. The maximal oxygen uptake (VO 2 % predicted) also decreased in both the surgical and N95 mask conditions. In addition, the severity of dyspnea increased, and exercise time decreased for both surgical and N95 masks. Compared to no mask, wearing an N95 mask led to lower breathing frequency and lower ventilation efficacy (assessed by VE/VCO 2 and VE/VO 2 ) from rest to maximal exercise (all p < 0.05 for trend). Wearing an N95 also led to retention of carbon dioxide (p < 0.05 for trend). Conclusions: Wearing a surgical mask leads to a somewhat negative impact on cardiopulmonary function, and this effect is more serious with an N95 mask. Attention should be paid to exercise while wearing surgical or N95 masks. shortness of breath, and radiographic evidence of pneumonia. [3] [4] [5] As of March 14, 2021, more than 100 million confirmed cases had been reported, and confirmed deaths had reached 2.6 million. 6 Reducing the rate of newly confirmed cases is a key strategy to reduce mortality. Person-to-person transmission of SARS-CoV-2 was demonstrated at an early stage of the disease. 7, 8 Airborne transmission is the dominant route of transmission. 9,10 Wearing a mask can reduce the flow of respiratory droplets into the air when the wearer coughs, sneezes, or talks and can decrease the inhalation of these droplets by another wearer. 11, 12 Evidence shows that wearing a mask is associated with a lower risk for infection. 13, 14 Therefore, universal mask wearing in public settings is recommended or mandated in the US, China, Germany, France, Italy, and other countries. 15 However, it have led to widespread debate on the risks present during exercise while wearing a mask. 16, 17 Observations of the physiological effects of wearing a mask during exercise are needed to identify such risks. This study explored the physiological effects of wearing a surgical mask (SM) and an N95 mask during exercise. At the end of 2020, 12 non-smoking, healthy volunteers were recruited. All of the volunteers were healthcare workers in our hospital; 6 were male, and 6 were female. Subjects who had chronic respiratory disease, cardiac disease, inflammatory disease, or acute respiratory illness (e.g., pneumonia and upper respiratory tract disease) within the 2 weeks prior to the study were excluded. We also excluded subjects with contraindications for cardiopulmonary exercise testing (CPET). The ethics committee of the First Affiliated Hospital of Chongqing Medical University approved the study protocol (No. 2020-888). Written informed consent was obtained from the participants. When volunteers were enrolled, their height (cm) and weight (kg) were measured, and then their body mass index (BMI) was calculated. Three consecutive symptom-limited incremental exercise tests were performed in each subject in the no mask (NM), disposable SM, and N95 mask (without exhalation valve) conditions. The fitting of the SM and N95 is presented in Figure 1 . The SM and N95 were made in China (Chongqing BaiNa Medical Instrument Co., Chongqing, and Henan Zhongjian Medical Instrument Co., Henan, respectively). All masks were worn under a standard silicone mask (Cosmed, Italy). Leak tightness was confirmed before each test. As this was a randomized crossover study, the order of mask wearing was assigned in a randomized fashion. Mask testing was performed by a technologist at the same time of day at a minimum of 48 h apart and was supervised by a pulmonary physician. The program algorithm and presentation of the measured data were developed according to the specifications of the American Thoracic Society (ATS) and the European Respiratory Society (ERS). 18, 19 Prior to data acquisition, the flow and volume calibration of the equipment was performed with a 3 L calibration syringe, and the gas analyzer was calibrated with atmospheric air and a cylinder with a fixed amount of O 2 (16%) and carbon dioxide (CO 2 ) (5%). Spirometry (Quark spiro COSMED, Italy) was performed without a mask before the CPET according to the standards in the 2005 ATS/ERS spirometry guideline. 20 CPET was performed using a computer-controlled bicycle ergometer (Ergoline 100/200, Bitz, Germany) with a Quark System (Quark CPET, COSMED, Italy) located in an air-conditioned room with ambient temperature at 20-25°C and low relative humidity (<50%). The mass flow sensor and gas analyzers were calibrated before each test and met current standards for accuracy, reproducibility, and response time. 21 During the CPET, the participants rested quietly on the bicycle for 3 minutes and conducted a warm-up of unloaded pedaling for 3 minutes. After this, the workload increased every 1 minute by 15 watts for female participants and 20 watts for males using prediction equations that took into account the physical characteristics of the participants until exhaustion.21 A cycling rate of 55-65 revolutions per minute (rpm) was used. The recovery time for each participant was 3 minutes. The test was terminated when the participants reported exhaustion or were unable to keep the ergometer at >50 rpm. Exhaustion was defined as unbearable leg weakening or dyspnea. The severity of dyspnea was assessed by the participants using the Borg dyspnea scale at peak exercise. The data were measured breath-by-breath and averaged over 20-second intervals. Maximum VO 2 was the highest VO 2 over a 20-second interval obtained at the end of exercise. The maximal power was recorded after exercise testing. Using breath-gas analyses, the following were continuously monitored: tidal volume, minute ventilation (VE), oxygen uptake (VO 2 ), carbon dioxide production (VCO 2 ), breathing frequency, inspiratory flow, end-tidal carbon dioxide (PETCO 2 ), heart rate (HR), and hemoglobin saturation (measured by finger oximeter). Blood pressure was measured automatically (Suntech Tango M2) at rest, during warm-up, at 2-minute intervals throughout exercise, and at the third minute of recovery. The ventilatory equivalents for carbon dioxide (VE/VCO 2 ) and for oxygen (VE/VO 2 ) were calculated. The anaerobic threshold (AT) was determined with the V-slope method using a 10-second interval. This was confirmed by the specific trends of VE/VO 2 , VE/VCO 2 , and PETCO 2 . 22, 23 The AT was determined by consensus between the two pulmonologists supervising all tests. Total exercise time, defined as the time elapsed from exercise commencement to exhaustion, was recorded. The reduction percentage of VO 2 max and VE with SM and N95 was calculated on the base of VO 2 max without a mask. Data were analyzed using statistical software (SPSS 23.0; IBM Corp., Armonk, NY) and were expressed as mean values and standard deviations or frequencies and percentages. Differences between patients with NM, SM, and N95 were analyzed with repeated-measures ANOVA. The least-significant difference for the post hoc test was used to analyze the difference between two groups. P values less than 0.05 indicated statistical significance. The demographic data of the 12 volunteers are presented in Table 1 . Their ages ranged from 30 to 41 years and the mean BMI was 21±3 kg/m 2 . The respiratory parameters are summarized in Table 2 and Figure 2 . Inspiratory flow gradually increased from rest to maximal exercise regardless of mask condition, whether NM, SM, or N95. Wearing an SM or N95 mask significantly decreased inspiratory flow, decreased VE, and prolonged inspiratory time at rest, warm-up, AT, and maximal exercise (all p < 0.05). Breath frequency was also significantly lower for SM and N95 than NM, except at maximal exercise (p < 0.05). Oxygen pulse (VO 2 /HR) gradually increased from rest to maximal exercise in all conditions (Table 2 and Figure 3 ). The SM and N95 conditions showed lower oxygen pulse at rest, warm-up, and maximal exercise (all p < 0.05). Oxygen uptake (VO 2 ) also decreased at rest, warm-up, and maximal exercise both in SM and N95 (vs. NM, all p < 0.05). At the anaerobic threshold, SM led to a reduction in oxygen uptake and oxygen pulse (p < 0.05). In addition, N95 showed higher carbon dioxide (PETCO 2 ), lower breathing frequency, and lower ventilation efficacy (VE/VCO 2 and VE/VO 2 ; Figure 4 , all p < 0.05 for trend). The reasons for failure to maintain the ergometer at >50 rpm are presented in Table 3 . However, one volunteer prematurely terminated CPET due to blood pressure beyond 200 mmHg. The main reason for termination was unbearable leg weakening. No volunteers reported unbearable dyspnea while not wearing a mask. Two volunteers reported unbearable dyspnea with an SM and five did so with an N95 mask. At maximal exercise in the NM condition, the 12 volunteers reached 79±12% of predicted maximal oxygen uptake. However, those wearing an SM or N95 only reached 63±9% and 66±10% of predicted maximal oxygen uptake, much lower than the NM condition ( Figure 5 ; all p < 0.05). Furthermore, exercise time decreased, and the Borg scale increased in volunteers with SM and N95 compared to those without a mask (all p < 0.05). The maximal power was also lower in volunteers with an N95 than those without a mask (p < 0.05). In our study, wearing a mask was associated with perceived shortness of breath and decreased exercise time. Wearing an N95 seems to be associated with more negative impact on exercise. The reasons for this may be rooted in a reduction of inspiratory flow, minute ventilation, oxygen uptake, and oxygen pulse from rest to maximal exercise. Wearing a mask is associated with decreased risk for infection, but it causes resistance to inhalation and exhalation. Previous studies have reported that wearing an SM or N95 is associated with reductions in FEV 1 , FVC, and PEF at rest.24,25 Another study reported that wearing an N95 leads to an increment of inspiratory and expiratory flow resistance. 26 In our study, we did not perform a pulmonary function test when the SM and N95 were used. However, we found that inspiratory flow was decreased and inspiratory time was prolonged at rest while wearing an SM or an N95. This indicates that inspiratory resistance increased while wearing an SM or an N95, which supports previous studies. Importantly, increased inspiratory resistance while wearing an SM or an N95 can increase inspiratory force, which is the main cause of dyspnea and decreased exercise tolerance. Wearing an N95 was associated with higher PETCO 2 than in the NM condition. This supports the finding of a previous study. 27 In addition, we found a trend of lower VE/VO 2 and lower VE/VCO 2 in N95 than in NM. Thus, N95 had a negative impact on exercise. A previous study showed that wearing an N95 resulted in a reduction of air-exchange volume by 37%. 26 Another study showed that PETCO 2 was significantly higher after a 6-minute walk with a mask than a walk without a mask in patients with chronic obstructive pulmonary disease. 28 All of these results indicate that wearing an N95 could lead to an enlargement of dead cavities and repeated inhalation of CO 2 during exercise. This shows that exercise with a mask, particularly with an N95, produced the risk for CO 2 retention. In addition, ventilation efficacy (assessed by VE/VCO 2 and VE/VO 2 ) also decreased while wearing an N95 in our study. This could explain the severe impact of N95 on dyspnea and exercise tolerance. Thus, N95 masks should be worn during exercise only with caution, particularly during high-intensity exercise and in those with chronic pulmonary disease. Fikenzer et al. 24 found no differences in tidal volume and VE at rest while wearing SM or N95 compared to NM. Mapelli et al. 25 found that the tidal volume was not different, but VE was reduced at rest, while wearing an SM or an N95, and only VO 2 was reduced while wearing an N95 compared to NM. However, we found that tidal volume, VE, VO 2 , and VO 2 /HR were decreased both at rest and warm-up, regardless of whether an SM or an N95 was worn. This indicates that wearing an SM or an N95 somewhat influences the cardiopulmonary function of routine low-intensity work. VO 2 /HR was higher at rest, warm-up, and maximal exercise while wearing an SM or an N95 in our study. Because no differences were seen in heart rate between the NM, SM, and N95 conditions, the reduction in VO 2 /HR can be attributed to a reduction of VO 2 . Wearing an SM or an N95 significantly increased respiratory resistance, which can lead to a reduction in VE. 26 This can explain why the oxygen uptake was reduced. sample size was not able to identify sex-based differences. Second, one volunteer terminated the CPET due to hypertension. Thus, the cardiopulmonary effects of mask wearing on exercise may not be fully reflected. Third, the subjects in our study were young and had no chronic cardiopulmonary disease, inflammatory disease, or acute respiratory illness. Thus, these results cannot be directly extrapolated to other populations but can be used, with caution, as a reference. In healthy subjects, wearing an SM led to a somewhat negative impact on cardiopulmonary function, and this effect was greater for wearing an N95 mask. Attention should be paid to exercise while wearing an SM or an N95 mask. p for difference between participants in the NM, SM, and N95 conditions NM = no mask, SM = surgical mask, AT = anaerobic threshold, PETCO 2 = partial pressure end-tidal carbon dioxide, HR = heart rate, VO 2 = oxygen uptake, FiO 2 = fraction of inspiratory oxygen, FeO 2 = fraction of expiratory oxygen p for difference between participants in the NM, SM, and N95 conditions Some volunteers reported more than one reasons for failure to keep the ergometer >50 rpm. One volunteer prematurely terminated CPET due to blood pressure beyond 200 mmHg. A new coronavirus associated with human respiratory disease in China A pneumonia outbreak associated with a new coronavirus of probable bat origin Epidemiological and clinical characteristics of 99 cases of 2019 novel coronavirus pneumonia in Wuhan, China: a descriptive study Clinical features of patients infected with 2019 novel coronavirus in Wuhan, China Clinical Characteristics of Coronavirus Disease 2019 in China Weekly Operational Update on COVID-19 A familial cluster of pneumonia associated with the 2019 novel coronavirus indicating person-to-person transmission: a study of a family cluster Early Transmission Dynamics in Wuhan, China, of Novel Coronavirus-Infected Pneumonia Airborne transmission of SARS-CoV-2 is the dominant route of transmission: droplets and aerosols Airborne Transmission of SARS-CoV-2: Theoretical Considerations and Available Evidence Physical distancing, face masks, and eye protection to prevent person-to-person transmission of SARS-CoV-2 and COVID-19: a systematic review and meta-analysis Preventing the Spread of SARS-CoV-2 With Masks and Other "Low-tech" Interventions Reduction of secondary transmission of SARS-CoV-2 in households by face mask use, disinfection and social distancing: a cohort study in Beijing, China Association Between Universal Masking in a Health Care System and SARS-CoV-2 Positivity Among Health Care Workers A technical review of face mask wearing in preventing respiratory COVID-19 transmission Exercise with facemask; Are we handling a devil's sword?" -A physiological hypothesis COVID-19: Electrophysiological mechanisms underlying sudden cardiac death during exercise with facemasks Statement on cardiopulmonary exercise testing Clinical exercise testing with reference to lung diseases: indications, standardization and interpretation strategies. ERS Task Force on Standardization of Clinical Exercise Testing Standardisation of spirometry Principles of exercise testing and interpretation A new method for detecting anaerobic threshold by gas exchange Clinical Exercise Testing, in Principles of Exercise Testing and Interpretation Including Pathophysiology and Clinical Applications Effects of surgical and FFP2/N95 face masks on cardiopulmonary exercise capacity You can leave your mask on": effects on cardiopulmonary parameters of different airway protection masks at rest and during maximal exercise Objective assessment of increase in breathing resistance of N95 respirators on human subjects Return to training in the COVID-19 era: The physiological effects of face masks during exercise Risks of N95 Face Mask Use in Subjects With COPD We are grateful to the 12 healthcare workers in our hospital as volunteers to join in this study. Lili Shui and Jun Duan conceived this study, performed the study design, data analysis and data interpretation, and drafted the manuscript. Lili Shui, Binbin Yang, Hong Tang, Yan Luo, Shuang Hu and Xiaoqing Zhong performed the CPET and joined in data collection. All of the authors read and revised the final version of the manuscript. Jun Duan took responsibility for the integrity of the work as a whole. None. We declare that there is no conflict of interest in this study.