key: cord-1028357-48a19rul authors: Kumar, A.; Weng, Y.; Graglia, S.; Chung, S.; Duanmu, Y.; Lalani, F.; Gandhi, K.; Lobo, V.; Jensen, T.; Kugler, J. title: Interobserver Agreement of Lung Ultrasound Findings of COVID-19 date: 2020-08-18 journal: nan DOI: 10.1101/2020.08.16.20176156 sha: 703d93f2e0b7b7a3dcfae4ae53b8bb8eb1a74ca0 doc_id: 1028357 cord_uid: 48a19rul Background: Lung ultrasound (LUS) may be used in the diagnostic evaluation of patients with COVID-19. An abnormal LUS is associated with increased risk for ICU admission in COVID-19. Previously described LUS manifestations for COVID-19 include B-lines, consolidations, and pleural thickening. The interrater reliability (IRR) of these findings for COVID-19 is unknown. Research Question: What is the interrater reliability of lung ultrasound findings in patients with RT-PCR confirmed COVID-19? Study Design and Methods: This study was conducted at conducted at two academic medical centers between 03/2020-06/2020. Nine physicians (hospitalists: n=4; emergency medicine: n=5) independently evaluated n=20 LUS scans (n=180 independent observations) collected from RT-PCR confirmed COVID-19 patients. These studies were randomly selected from an image database consisting of COVID-19 patients evaluated in the emergency department with portable ultrasound devices. Physicians were blinded to any patient information or previous LUS interpretation. Kappa values were used to calculate IRR. Results: There was substantial IRR on the following items: normal LUS scan (K=0.79 [95% CI: 0.72-0.87]), presence of B-lines (K=0.79 [95% CI: 0.72-0.87]), >=3 B-lines observed (K=0.72 [95% CI: 0.64-0.79]). Moderate IRR was observed for the presence of any consolidation (K=0.57 [95% CI: 0.50-0.64]), subpleural consolidation (K=0.49 [95% CI: 0.42-0.56]), and presence of effusion (K=0.49 [95% CI: 0.41-0.56]). Fair IRR was observed for pleural thickening (K=0.23 [95% CI: 0.15-0.30]). Interpretation: Many LUS manifestations for COVID-19 appear to have moderate to substantial IRR across providers from multiple specialties utilizing differing portable devices. The most reliable LUS findings with COVID-19 may include the presence/count of B-lines or determining if a scan is normal. Clinical protocols for LUS with COVID-19 may require additional observers for the confirmation of less reliable findings such as consolidations. Tables List -Table 1 . Patient Characteristics. Table 2 . Interobserver Agreement of Lung Ultrasound Findings Among COVID-19 Patients. Table 3 . Interobserver Agreement of Lung Ultrasound by Lung Field Location Keywords: POCUS, ultrasound, lung, COVID-19, SARS-CoV-2, interobserver agreement, reliability, interrater. Point-of-care ultrasound (POCUS) has the potential to transform healthcare delivery in the era of COVID-19 with its diagnostic expediency. 1 POCUS provides real-time interpretation of a patient's condition in an augmented clinical manner, which can immediately impact management decisions. 2,3 POCUS devices, particularly handheld devices, are often cheaper than traditional radiological equipment such as X-ray or computerized tomography (CT) machines, which makes POCUS ideal for COVID-19 surge scenarios where these resources may be limited. 4, 5 Furthermore, POCUS may reduce the number of providers exposed to patients with COVID-19 by decreasing the need for radiological studies, which could result in decreases of personal protective equipment usage by radiological technicians and the resources needed to decontaminate larger radiological equipment. 4 Previously reported pulmonary manifestations of COVID-19 with POCUS include B-lines, subpleural consolidations, pleural thickening, and absence of pleural effusions. [4] [5] [6] [7] [8] POCUS has been proposed to aid in the diagnosis of COVID-19, 9 as well as to predict intensive care unit (ICU) admission or death. 10 Given the potential for POCUS to predict outcomes among COVID-19 patients, there is a significant need to determine if these findings can be reliably interpreted among providers. Outside of COVID-19, previous investigations have found moderate to excellent interobserver agreement for many lung ultrasound (LUS) findings, including B-lines, consolidations, and effusions. 2, 11, 12 In this study, we characterize the interobserver agreement of LUS findings that have been described for COVID-19. These images were collected using portable ultrasound devices, which may be more commonly utilized as a result of the COVID-19 pandemic. This analysis was conducted as part of an ongoing study investigating the role of POCUS for COVID-19 that is being conducted at four medical centers in the United States (Clinicaltrials.gov Registration: NCT04384055). This investigation utilizes a prospectively collected database and includes adult patients who meet the following criteria: 1) presentation to the emergency department with symptoms 13 suspicious for COVID-19, 2) a positive nasopharyngeal RT-PCR for SARS-CoV-2, and 3) received a lung ultrasound (LUS) during their emergency department course or subsequent hospitalization (up to 28 days from admission). This study has received institutional review board (IRB) approval at all participating sites. In this study, a total of n=20 LUS scans collected between 3/2020 and 6/2020 were randomly selected from our image database consisting of COVID-19 POCUS images. These scans originated from n=13 patients, which occurred because some patients received multiple scans . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted August 18, 2020. . during a 28-day period. Any scans from the same patient were acquired on different days. All scans were collected using a 12-zone lung protocol, which we have previously described and is also demonstrated in Figure 1 . 6 Each zone clip was 6 seconds in length. 6 The LUS studies were collected on the following devices: Butterfly iQ (n=9), Vave Personal Ultrasound (n=6), Philips Lumify (n=4), and Sonosite M-turbo (n=1), which represent the commercially-available portable devices at our institutions. In our study protocol, providers can acquire these scans using any portable device available to them, and the types of devices used in this analysis were the result of random selection from our database. This study included nine physicians from two specialties (hospitalists n=4; emergency medicine, n=5) who are regular users of LUS and have leadership positions in POCUS at their respective institutions. These nine physicians independently evaluated n=20 LUS scans (n=180 independent observations). The physicians were blinded to any patient information or previous interpretation. All physicians received a document that contained the scanning protocol ( Figure 1 ) as well as definitions for each of the pathological findings ( Figure 1 ). The physicians met for a 1-hour calibration session at the beginning of the study to review sample videos and discuss their realtime interpretations. These samples were not included in the interrater analysis. The physicians were then instructed to independently assess the 20 de-identified studies and input their interpretation using a central electronic database (REDCap). 14 No other instruction on image interpretation was provided to the group during the independent assessment period. The degree of agreement for Kappa values were based on the research originally described by Cohen and later Landis & Koch. [15] [16] [17] In our study, Fleiss kappa statistics and corresponding 95% confidence intervals were reported. In this scheme, we interpreted the Fleiss' kappa statistics 17 with the following criteria: κ<0 (no agreement), κ=0-0.20 (none to slight agreement), κ=0.21-0.40 (fair agreement), κ=0.41-0.60 (moderate agreement), κ=0.61-0.80 (substantial agreement), κ=0.81-1.0 (near perfect agreement). All analyses were performed using R statistical programming language, version 3.6.1 (Vienna, Austria). A. Study Population Patient demographics and clinical characteristics are described in Table 1 . The mean body mass index (BMI) for the patient population was 30.5 kg/m 2 (range 24.6-37.5). The mean age for the study cohort was 49.2 (SD 19.2). Approximately 57% of the patients were female (Table 1) B. Normal Vs. Abnormal Scan Overall, there was substantial agreement on determining whether a scan contained no abnormalities, including absence of B-lines, consolidations, pleural thickening, or effusions (κ=0.79 [95% CI: 0.72-0.87]; Table 2 ). . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 18, 2020. . There was substantial interrater agreement on the presence of B-lines (κ=0.79 [95% CI: 0.72-0.87]) or whether the scan contained three or more B-lines per lung field (κ=0.72 [95% CI: 0.64-0.79]; Table 2 ). The presence of bilateral B-lines also demonstrated substantial agreement (κ=0.70 [95% CI: 0.63-0.78]; Table 3 Table 3 ). Notably, the total count of B-lines per scan had slight agreement (κ=0.16 [95% CI: 0.14-0.17]). There was moderate interrater agreement on the presence of any consolidation (κ=0.57 [95% CI: 0.50-0.64]; Table 3 ). In this study, we investigated the interobserver agreement of LUS findings that have been previously described with COVID-19. Several LUS findings demonstrated substantial agreement (e.g. B-lines), while others demonstrated moderate to fair agreement (e.g. consolidations, pleural thickening, or effusions). This study represents the first investigation of the interobserver agreement of LUS findings in COVID-19 and includes practitioners from multiple specialties who utilized several portable devices. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 18, 2020. . There are several implications of these findings. Previous authors have demonstrated the presence of B-lines can be used in the diagnostic evaluation for COVID-19. 6, 9 Others have proposed that bilateral B-lines on LUS increase the risk of ICU admission or death with COVID-19. 10 Our results suggest that there is substantial interobserver agreement for the presence of Blines across multiple provider specialties utilizing different handheld devices. Therefore, the presence of B-lines may represent a reliable, diagnostic, and prognostic clinical entity for COVID-19. Similarly, there was substantial agreement on whether a LUS scan was interpreted as abnormal vs. normal. While the prognostic value of a normal LUS for COVID-19 remains uncertain, others have shown that chest radiograph abnormalities with COVID-19 are associated with ICU admission. 18 Furthermore, an abnormal LUS scan (outside of COVID-19) has prognostic implications across multiple diseases. [19] [20] [21] Future studies are needed to determine if LUS can reliably predict clinical outcomes with COVID-19. How do these findings compare to the interrater reliability literature for LUS outside of COVID-19? Previous investigations have demonstrated moderate to substantial agreement for B-lines [22] [23] [24] [25] . In contrast, there is only moderate to fair agreement for consolidation 11,12,22 , pleural irregularity 22 , and effusions. 11, 22 Others have shown that there is substantial interrater reliability for LUS across differing probes (e.g. linear vs. phased array) 25,26 , which is important given different portable devices were used in this investigation. Future investigations of LUS for COVID-19 should consider multiple observers to confirm less-reliable findings and utilize a standardized interpretation protocol. This latter point may be important because there are variable definitions of LUS findings in the literature, especially for consolidations. 5, 11, 12, 22 . Although consolidations had moderate agreement in this study, the reliability of this finding might improve with more specified definitions and consensus-based guidelines. There are several limitations to this study. Our study population was confined to patients who presented to the emergency department or were hospitalized, which limits the generalizability of these findings for providers in the outpatient setting. Although we randomly selected LUS studies from our database, we sampled fewer patients (n=13) than the total number of scans analyzed (n=20). The researchers in this study completed a 1-hour calibration session and had a definition sheet when interpreting images. Therefore, the IRR may be lower for certain findings among less-trained practitioners. Although this study utilized several portable devices, there was variability in the image quality of these devices (particularly when visualizing the pleural line), which may have affected the results regarding pleural thickening or subpleural consolidation. Despite these limitations, this study represents one of the first dedicated investigations into the interobserver agreement of LUS findings for COVID-19. In conclusion, many LUS manifestations for COVID-19 appear to have substantial to moderate IRR across providers from multiple specialties utilizing differing portable devices. More reliable findings included the determination of a normal scan, the presence and location of B-lines, and . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 18, 2020. . determining if >=3 B-lines were present. Less reliable findings related to the presence or locations of consolidations, pleural thickening, or effusions. Since presence of B-lines may have diagnostic and prognostic utility for COVID-19, this finding can likely be interpreted without additional oversight and can be incorporated into future clinical protocols. In contrast, other findings such as pleural thickening may be less reliable, and clinical protocols incorporating these findings may require quality assurance for accurate interpretation. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 18, 2020. . https://doi.org/10.1101/2020.08. 16 The degree of agreement was based on previously reported methodology. 17 Effusion size was defined as <1cm from the visceral and parietal pleura vs. >=1 cm. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 18, 2020. Table 3 . Interobserver Agreement of Lung Ultrasound by Lung Field Location. Lung zones (anterior, lateral, and posterior) are described in Figure 1 . . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted August 18, 2020. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted August 18, 2020. . https://doi.org/10.1101/2020.08. 16.20176156 doi: medRxiv preprint Point-of-Care Ultrasonography The Role of Technology in the Bedside Encounter Point-of-care ultrasound and COVID-19 Clinical Progress Note: Point-of-Care Ultrasound Applications in COVID-19 Lung Ultrasound Findings in Patients Hospitalized with Covid-19 Sonographic signs and patterns of COVID-19 pneumonia Ultrasound in COVID-19: a timeline of ultrasound findings in relation to CT Accuracy of Emergency Department Clinical Findings for Diagnosis of Coronavirus Disease in the Interpretation of Lung Ultrasound Studies Performed on Mechanically Ventilated Patients Lung ultrasound in the critically ill. Ann Intensive Care Centers for Disease Control and Prevention Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support Weighted kappa: nominal scale agreement with provision for scaled disagreement or partial credit The measurement of observer agreement for categorical data Measuring nominal scale agreement among many raters Development and Validation of a Clinical Risk Score to Predict the Occurrence of Critical Illness in Hospitalized Patients With COVID-19 Prognostic Value of Lung Ultrasound B-Lines in Systemic Sclerosis Quantitative lung ultrasonography: a putative new algorithm for automatic detection and quantification of Blines. Crit Care Relevance of B-Lines on Lung Ultrasound in Volume Overload and Pulmonary Congestion: Clinical Correlations and Outcomes in Patients on Hemodialysis Interrater reliability of pediatric point-of-care lung ultrasound findings Interobserver agreement in the evaluation of B-lines using bedside ultrasound