key: cord-1027503-u05y8krb authors: Igloi, Z.; Velzing, J.; van Beek, J.; van de Vijver, D.; Aron, G.; Ensing, R.; Benschop, K.; Han, W.; Boelsums, T.; Koopmans, M.; Geurtsvankessel, C.; Molenkamp, R. title: Clinical evaluation of the Roche/SD Biosensor rapid antigen test with symptomatic, non-hospitalized patients in a municipal health service drive-through testing site. date: 2020-11-20 journal: nan DOI: 10.1101/2020.11.18.20234104 sha: de20972dd0222b822c62a99ff72741c026499af0 doc_id: 1027503 cord_uid: u05y8krb Background Rapid detection of infectious individuals is essential in stopping the further spread of SARS-CoV-2. Although rapid antigen test is not as sensitive as the gold standard RT-PCR, the time to result is decreased by day(s), strengthening the effectiveness of contact tracing. Methods The Roche/SD Biosensor lateral flow antigen rapid test was evaluated in a mild symptomatic population at a large drive through testing site. A second nasopharyngeal swab was directly tested with the rapid test on site and results were compared to RT-PCR and virus culture. Date of onset and symptoms were analysed using data from a clinical questionnaire. Results We included 970 persons with complete data. Overall sensitivity and specificity were 84.9% (CI95% 79.1-89.4) and 99.5% (CI95% 98.7-99.8) which translated into a positive predictive value of 97.5% (CI95% 94.0-99.5) under the current regional PCR positivity of 19.2%. Sensitivity for people with high loads of viral RNA (ct <30, 2.17E+05 E gene copy/ml) and who presented within 7 days since symptom onset increased to 95.8% (CI95% 90.5-98.2). Band intensity and time to result correlated strongly with viral load thus strong positive bands could be read before the recommended time. Around 98% of all viable specimen with ct <30 were detected successfully indicating that the large majority of infectious people can be captured with this test. Conclusion Antigen rapid tests can detect mildly symptomatic cases in the early phase of disease thereby identifying the most infectious individuals. Using this assay can have a significant value in the speed and effectiveness of SARS-CoV-2 outbreak management. The Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has emerged almost a year ago [1] but it still keeps a strong grip not only on our daily life but also on the diagnostic capacities. Reverse transcriptase polymerase chain reaction (RT-PCR) has been the gold standard for diagnosis of acute infection [2] but has several limitations, such as the requirement for specialised laboratory infrastructure, trained personnel and reagents that have been in shortage globally [3] . In addition, the current turnaround time from sample collection to reporting of the result may take up to more than 48 hours [4] mainly due to the need to transport samples to laboratories, compromising effectiveness of triage, isolation and contact tracing strategies. Rapid antigen detection tests (Ag RDT) for SARS-CoV2 appeared on the market earlier 2020 but initial reports of poor performance and the lack of independent evaluation results made governments reluctant to invest and consider the inclusion into testing algorithms. Currently there are 73 (and the number is growing) assays on the market [5] but few have been extensively validated [5] [6] [7] . Initial results showing that these tests are suitable detecting early onset cases with high viral load. As expected, the sensitivity of the tests is lower compared to RT-PCR, but in patients in the early phase of illness onset and with high viral load the performance meets the WHO set criteria of at least ≥80% sensitivity and ≥97% sensitivity compared to nucleic acid detection methods as gold standard [8] . Thus these tests could be useful in identifying the most infectious individuals [4] . In an outbreak scenario diagnostics with lower sensitivity but a faster result can render interventions more effective than gold standard tests [9] . Implementation of Ag RDT into testing algorithms would allow rapid detection and isolation of new cases and thereby support the test, trace and isolate strategy, aiming to stop transmission chains and reduce the impact of COVID-19. In this study we aimed to assess the performance of the SD Biosensor SARS-CoV-2 Rapid Antigen Test (distributed by Roche Diagnostics) compared to both RT-PCR and virus culture in 970 individual. The field evaluation study was carried out at a large municipal health facility where people presented mostly with mild symptoms. Every individual over 18 years of age with an appointment for SARS-CoV-2 RT-PCR testing was approached to be included. An additional nasopharyngeal swab was obtained for the Ag RDT in parallel and processed on-site in order to compare sensitivity/specificity to RT-PCR. All Ag RDT and PCR positive samples were cultured to correlate results with infectivity. The study was carried out at the largest drive through testing location in Rotterdam -Rijnmond (the second largest city in the Netherlands) which is by appointment only. Eligibility for a free of charge test includes either symptoms or close contact with a confirmed SARS-CoV-2 infected person. Most people presenting for testing had (mild) symptoms. At the entrance of the testing site all people over 18 years of age were approached for inclusion and following informed consent people were enrolled and directed to one of the dedicated testing stations for the Ag RDT. The people that were included were also asked to fill in a clinical questionnaire including the reason for appointment, date of onset or end date and a list of symptoms (fever, sore throat, coughing, shortness of breath / tightness, runny nose, diarrhoea, eye complaints, nausea, rash, chills, headache, pain when breathing, coughing phlegm, muscle pain, painful / swollen lymph nodes, fatigue, vomiting, joint pain, loss of appetite, nosebleed, other) . The study was carried out for 5 days in order to achieve the target of 800-1000 inclusions. Testing site setup and the mobile laboratory From the six available testing posts we designated two posts for sample collection from people who enrolled in this study. This was based on: i) the average number of study subjects per test post (approximately 150 per day), ii) the known number of appointments per day and iii) the expected enrolment rate based on initial results from other study sites within the Netherlands. We expected to include a maximum of 300 people per day. Swabbing was done by the regular crew of trained personnel to avoid variations to the process. Testing was done on a benchtop, in a mobile unit (kindly provided by RIVM) by trained staff dressed in full personal protective equipment (goggles, FFP3 mask, gloves and disposable gown; PPE). Samples for the Ag RDT were collected at regular intervals and processed in convenient batches (5-10 tests at one time). Training, when necessary, was given on site and did not take longer than 30 mins. Following readout results were recorded in an offline database (Microsoft Access) designated for this study and both the swab and RDT device were inactivated in chlorine and disposed of as biohazard material. Standard method for SARS-CoV-2 testing is by RT-PCR which was carried out as usual, in parallel with the Ag RDT. Two swabs (one oro-and one nasopharyngeal swab, OP and NP swab) were taken for RT-PCR and virus culture, placed directly in universal transport media (HiViral TM ) and shipped to the Erasmus MC Viroscience diagnostic laboratory. For the Ag RDT evaluation a second nasopharyngeal swab was taken from the same nostril using the swab included in the kits to directly compare RT-PCR result with the Ag RDT. Routine RT-PCR testing was performed on combined oro-and one nasopharyngeal swab in virus transport medium using the cobas ® SARS-CoV-2 test on the COBAS6800 (Roche diagnostics). Genome copies/ml were calculated based on an in house established standard curve. The virus transport medium from the same oro-and nasopharyngeal swabs were also directly inoculated onto Vero cells clone 118, without prior freezing [10] . Samples were cultured for seven days, and, once cytopathic effect (CPE) was visible, the presence of SARS-CoV-2 was confirmed with immunofluorescent detection of SARS CoV-2 nucleocapsid protein (Rabbit polyclonal antibody Sino Biological inc.) . For the Ag RDT the SARS-CoV-2 Rapid Antigen Test (Distributed by Roche (SD Biosensor) (REF No. 9901-NCOV-01G; LOT No QCO3020079/Sub:A-2) was carried out immediately on-site following manufacturer's instructions. A 4 grade scaling readout was utilized representing the strength of the band (++; +; +/-, -) and time till positive results was logged as less than 5 mins, less than 10 mins or 15 mins. When results were dubious, readout was performed independently by two persons. Data from the Ag RDT, RT-PCR, virus culture, and clinical questionnaire was merged using Microsoft Access, and data analysis was performed using R version 4.0.2. Sensitivity and specificity of Ag RDT was All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted November 20, 2020. ; https://doi.org/10.1101/2020.11.18.20234104 doi: medRxiv preprint calculated in relation to the RT-PCR results as the gold standard. The Wilcoxon score interval was used to determine confidence intervals of proportions. The medical research ethics committee (MREC) of Utrecht decided the study was not subject to the Medical Research Involving Human Subjects Act (WMO) and did not require full review by an accredited MREC (protocol number 20-606/C). During the 5 days of the study, on average 27.2% (n=970) of the people who visited the testing site could be included; the inclusion was put on hold occasionally during the day due to clogging of testing positions. Of the included people the average age was 42 years (range 18-86 years), the majority was female (n=525, 54.7%) and had symptom onset ≤7 days (n=650, 89.7%). The majority (84.9%) of the samples contained a high viral load (PCR cycle threshold ≤30, E gene copy/ml 2.17E+05) ( Table 1 ). The age and gender distribution of the people included in the study was representative of the tested population in general (average age 38.4 years and 57% female). We did not record reasons for not participating. At the time of requesting the appointment, a large majority of the participants had symptoms (91.3%), and most frequently reported cold symptoms and runny nose (64.5%), sore throat (57%), coughing (55%), headache (48%), tiredness (38%), muscle pain (27%), shortness of breath and chills (21%). Some of the more typical and serious symptoms like fever and reproductive cough were only reported by 17% of cases. A very small percentage (1.5%) reported loss of taste and smell. The overall sensitivity of the Ag RDT was 84.9% (CI95% 79.1-89.4) and specificity 99.6% (CI95% 98.6-99.9) with a positive and negative predictive value of 98.3% (CI95% 94.0-99.5) and 97.7% (CI95% 96.1-98.7) under an average of 19.2% current prevalence in the region calculated by PCR positivity rate in the test location. Sensitivity improved considerably when analysed by various PCR cycle threshold (ct) intervals showing highest sensitivity for ct values ≤25 (E gene copy/ml 4.87E+06) ( 99.1% CI95% 95.2-100 ) and 94.3% (CI95% 89.6-97.0) for ct values ≤30 (E gene copy/ml 2.17E+05). Also sensitivity in people that presented within the first 3 days of symptoms onset was higher than for people later in their disease progression (94.9% vs 90.6%) ( Table 2) . Overall, the sensitivity was strongly associated with viral load. Three from the four PCR (and culture) negative samples which were detected by the Ag RDT were negative by RT-PCR for other respiratory viruses, while one was weakly positive for rhinovirus (ct>35). Only in one of the samples could metagenomic sequencing identified Rhinovirus B. PCR positive samples which were not detected by the Ag RDT showed a mixed distribution of viral load (n=10/30