key: cord-1026582-5yxtwved authors: Ding, Zhen; Qian, Hua; Xu, Bin; Huang, Ying; Miao, Te; Yen, Hui-Ling; Xiao, Shenglan; Cui, Lunbiao; Wu, Xiaosong; Shao, Wei; Song, Yan; Sha, Li; Zhou, Lian; Xu, Yan; Zhu, Baoli; Li, Yuguo title: Toilets dominate environmental detection of severe acute respiratory syndrome coronavirus 2 in a hospital date: 2020-08-15 journal: Sci Total Environ DOI: 10.1016/j.scitotenv.2020.141710 sha: 4a56f984e8de82ba722b19152e02ca04519d80bb doc_id: 1026582 cord_uid: 5yxtwved Abstract Respiratory and fecal aerosols play confirmed and suspected roles, respectively, in transmitting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). An extensive environmental sampling campaign of both toilet and non-toilet environments was performed in a dedicated hospital building for patients with coronavirus disease 2019 (COVID-19), and the associated environmental factors were analyzed. In total, 107 surface samples, 46 air samples, two exhaled condensate samples, and two expired air samples were collected within and beyond four three-bed isolation rooms. The data of the COVID-19 patients were collected. The building environmental design and the cleaning routines were reviewed. Field measurements of airflow and CO2 concentrations were conducted. The 107 surface samples comprised 37 from toilets, 34 from other surfaces in isolation rooms, and 36 from other surfaces outside the isolation rooms in the hospital. Four of these samples were positive, namely two ward door handles, one bathroom toilet seat cover, and one bathroom door handle. Three were weakly positive, namely one bathroom toilet seat, one bathroom washbasin tap lever, and one bathroom ceiling exhaust louver. Of the 46 air samples, one collected from a corridor was weakly positive. The two exhaled condensate samples and the two expired air samples were negative. The fecal-derived aerosols in patients' toilets contained most of the detected SARS-CoV-2 in the hospital, highlighting the importance of surface and hand hygiene for intervention. be determined after detection of the virus in stools (Zhang et al., 2020a , Zhang et al., 2020b , Zhang et al., 2020c . Crucially, however, the relative importance of transmission by fomites, close contact, and the suspected fecal-oral route remains unknown. Significant infection has also occurred in hospitals. According to the China CDC Weekly 2020 (Novel Coronavirus Pneumonia Emergency Response Epidemiology Team, 2020), 1,716 of 44,672 COVID-19 cases confirmed in China by February 11, 2020 affected healthcare workers. Thus, understanding the infection risk in a hospital environment is essential to protecting healthcare workers. An environmental sampling campaign was performed in four occupied isolation rooms housing 10 COVID-19 patients in The Second Hospital of Nanjing, China, and the association between the sampling results and the environment and the risk of SARS-CoV-2 transmission were analyzed. The studied infectious disease hospital was built in 2015 and is now a designated hospital for receiving COVID-19 patients during the epidemic. The aim of this study was to identify the high-risk areas in a hospital containing COVID-19 patients and thus enable the adoption of adequate and effective interventions. Basic data of the COVID-19 patients in the sampled isolation rooms were first collected; these included the date of symptom onset, throat-sample polymerase chain reaction (PCR) results, CT scan findings, symptoms, and mask-wearing behavior. The data of these patients are summarized in Table S1 . On each date, patients and rooms were randomly chosen for sampling. J o u r n a l P r e -p r o o f Environmental sampling was conducted in four isolation rooms, a nursing station, a corridor, an air-conditioning system, and other spaces in the airborne infectious-disease zone on the fifth floor of the hospital (Figure 1a) . The hospital is a six-story building with a courtyard. The sampling was conducted on February 8, 20, and 22, 2020. At the time of sampling, only some of the 19 isolation rooms in the studied zone were occupied by 34 patients on February 8, 21 patients on February 20, and 34 patients on February 22. Each isolation room contained three beds and measured 7.9 m  3.9 m  8.2 m but was not necessarily fully occupied at the time of sampling. The sites of air and surface sample collection are shown in Figure 1 . A detailed list of air and surface samples is given in Table S2 . All samples were collected by a trained CDC officer who had a medical background, with assistance from two trained nurses from the hospital. The CDC officer wore full personal protective equipment (PPE), including an N95 respirator, goggles, face shield, gloves, shoe covers, cap, and gown. The CDC officer was quarantined for 12 days after the collection on February 8 and resumed sampling on February 20 and 22. Thereafter, he was quarantined again for another 14 days and again disinfected. For airborne-aerosol sampling, four bioaerosol samplers were used: an Andersen one-stage viable impactor (QuickTake-30, SKC, USA; sampled at 10 L/min for 30 min, Gibco 20 and 22), and a WA -15 (Dinglan Technology, Beijing, China; sampled at 14 L/min for 30 min on February 8; Youkang virus-sampling kit, Youkang Hengye Biotechnology, Beijing, China). To collect exhaled breath condensates, an AT-150 (Dingblue Technology, Beijing, China) was used to obtain samples from respiratory fluids, which aggregated on the hydrophobic film surfaces after freezing. To collect surface-wiped samples, a Youkang virus-sampling kit (Youkang Hengye Biotechnology, Beijing, China) was used. A cotton swab was moistened with the collection liquid and then used to wipe the surface of the object once. The sampling sites were extended to other areas in the hospital and its roof air-exhausts on February 20 and 22. The sampling duration of the ASE-100 was also increased from 2 min to 20 min. All sampling was conducted from 9:00 am to 12:30 pm, and the morning surface-cleaning in the hospital was arranged to be suspended. For the general routine, cleaning and disinfection of these rooms was conducted twice daily. The frequently touched surfaces were cleaned using a sodium dichloroisocyanurate solution containing 500 mg/L chlorine (disinfectant tablets, Lvshaxin Aiershi, Shanghai). During the morning round, cleaners wearing PPE entered at 8:30 am, emptied the waste bins from 8:30 to 9:00 am, cleaned environmental surfaces from 9:00 to 10:30 am, and exited at 11:00 am. During the afternoon round, cleaners entered at 2:00 pm and cleaned the same surfaces from 2:30 to 4:00 pm. In total, 107 surface samples, 46 air samples, two exhaled condensate samples, and two Figure 2 , which also includes the patients' information. The environmental sample detection methods included nucleic acid extraction (NP968, The chi-square test was used to determine whether there were statistically significant differences in the percentages of positive samples among different groups of surfaces. Specifically, the chi-square test statistic, χ 2 , was calculated and compared to a chi-square distribution to acquire the p-value. In this study, a p-value less than .05 was considered J o u r n a l P r e -p r o o f Journal Pre-proof statistically significant. The studied hospital was a dedicated COVID-19 patient hospital in Nanjing. The hospital is a six-story building, and the sampled area, patient zone no. 5, occupies part of the fifth floor ( Figure 1a ). Four patient rooms were monitored, and sampling was also conducted in the corridor and elsewhere on the floor and on the hospital roof. Unlike the sixth-floor wards, the fifth-floor wards, where environmental sampling was conducted, do not have anterooms. The CO 2 concentrations were measured in the rooms using an indoor air-quality meter (IAQ-Calc 7515, TSI, USA) for 24 min with four people present. Based on the CO 2 data, the outdoor air-supply rate was calculated to be 64 L/s (2.5 air-changes per hour, ACH). Using incense smoke, the airflow pattern was determined to lead from the corridor to each isolation room, and to subsequently exhaust via the bathroom. Of the 107 surface samples taken throughout and beyond the infectious disease zone, seven were positive (four positive and three weakly positive). These samples were collected from the inside door handle of the isolation room containing beds 16, 17, and 18 (Ct = 36.8, 407 407 RNA copies, February 20), and the exhaust air grille surface in the bathroom of the same room (Ct = 37.9, February 22). Note that we did not calculate the RNA copy numbers for the three weakly positive samples. Note also that five of seven positive/weakly positive samples were obtained from two bathrooms used by patients, and all of the throat swabs of at least one of these patients had been positive for two days before sampling. Among all other surface areas both within and beyond the isolation rooms, only two surface samples were positive, namely the door handles of Rooms 16-18 and 2-3. Figure 1A and 1B demonstrate that all surface samples outside of the patients' rooms were negative, as shown by a lack of solid red circles, while only the toilet area in one patient room was found to be contaminated, as shown by solid red circles in Figure 1C . Table 1 shows that positive surface samples were only detected in the rooms containing a patient whose throat swabs were all positive on a given day. The numbers of positive air samples and surface samples and the corresponding shortest symptom onsets in the sampling period are also shown. These results suggest that for the COVID-19 patients studied here, the toilet was the most contaminated environment, although the chi-square p-value is only 0.064 (Table 2 ). The detection of more positive surface samples in the bathrooms than elsewhere suggests that these samples may be fecal in origin. The previous detection of the virus in stools [3] [4] [5] 16, 18 supports this interpretation, as does the fact that stools obtained from the first COVID-19 patient in the United States also tested positive. 7 Zhang et al. 5 also observed more anal swab positives than oral swab positives in the later stage of infection, and approximately 10% of J o u r n a l P r e -p r o o f Journal Pre-proof the patients in Wuhan presented with diarrhea and nausea prior to fever and dyspnea (Wang et al., 2020) . In other studies, diarrhea and nausea have been observed in one-third of patients (Foladori et al., 2020) . High levels of viral load were also detected in the stools of SARS-CoV patients (Peiris et al., 2003) . The detection of positive surface samples on one toilet ceiling exhaust grille in a bathroom suggests that fine virus particles existed in that bathroom. Deposition on exhaust grille surfaces can result from either the long-term deposition of low-concentration particles in the air or the rapid deposition of high-concentration particles. Three possible sourcesof fine airborne aerosols exist in the bathroom: exhaled release from patients when using the bathroom, toilet-generated aerosols from feces and urine when the toilets are flushed (Gerba et al., 1975) , and import of airborne particles from the cubicles where the patients spend most of their time. Ong et al. (2020) also detected SARS-CoV-2 in an air-outlet fan. Among surfaces in a patient ward, including a bench, bedside rail, locker, bedside table, alcohol dispenser, and windowsill, Cheng et al. (2020) found that only the windowsill sample (1/13) was positive for SARS-CoV-2 even when the viral loads of the patients were 3.3  10 6 copies per mL in the pooled nasopharyngeal sample and throat swab and 5.9  10 6 copies per mL in saliva. A patient's hands can be contaminated during toilet usage. Consistent with this observation, the toilet bowl and sink surface samples in a Singaporean hospital also tested positive for SARS-CoV-2. (Ong et al., 2020) . In addition to aerosols generated by toilet flushing, Yu et al. (2004) found that during the 2003 Amoy Garden outbreak, SARS-CoV bio-aerosols were generated in drainage stacks after patients flushed the toilets. A toilet is housed in a small area that is commonly shared by patients in relatively large J o u r n a l P r e -p r o o f Journal Pre-proof isolation rooms. The personal spaces of these patients overlap in the toilet area and thus are likely to generate an additive contamination effect. This effect may explain why the toilet surfaces were particularly likely to be positive for SARS-CoV-2. Nevertheless, the duration of a patient's visit to the toilet would have been brief, as only mildly symptomatic patients were housed on the tested floor. Additionally, the surface material or finish inside a toilet may allow a better transfer during swab-sampling than the other sampled surfaces. In this context, there is generally a higher surface-touch transfer rate from smooth to rough surfaces, and most toilet surfaces are made to be smooth (Zhao et al., 2019) . No virus was detected on non-toilet object surfaces in the patients' rooms, in contrast to a 2020 study by Ong et al. (2020) wherein 13 of 15 (87%) samples in one patient's room and three of five (60%) toilet sites were positive, although anteroom and corridor samples were negative. Interestingly, the patient in that earlier study had no pneumonia or diarrhea but provided stool samples that were positive for SARS-CoV-2. Forty-five of the 46 air samples were negative. The only weakly positive air sample was obtained from the corridor close to the patients' isolation rooms and was collected on February 20 using the ASE-100 with a total air-volume of 10 m 3 . The exact location of the weakly positive sample is shown in Figure 1B (sample location no. 25). Of the two exhaled condensate samples, both were negative. We characterized the airflow pattern in the hospital zone using incense smoke, which revealed a weak flow from all isolation rooms to their shared corridor, as shown in Figure S1 . In other words, none of these rooms had negative pressure, despite the continuous operation of a relatively strong exhaust fan in the bathrooms of all isolation rooms. Therefore, aerosols may have been leaked from the isolation rooms to the corridor. Airborne aerosols may have also been released from the PPE worn by healthcare J o u r n a l P r e -p r o o f Journal Pre-proof workers into the environment in the multi-function room. We were not able to quantitatively measure the airflow in that zone. The above described detection of the virus in the corridor air (only weakly positive, and lower than the limit of quantification) and also on the surfaces of exhaust grilles in the bathrooms suggests the possible existence of airborne virus particles. Previous evidence suggested the airborne transmission of SARS-CoV in hospital wards (Li et al., 2005) . Both Ong et al. (2020) and Cheng et al. (2020) failed to detect any SARS-CoV-2-positive air samples, although this may have been due to the fact that the former group sampled only 1.2 m 3 or 1.5 m 3 air, depending on the sampler used, while the latter collected only 1 m 3 of air. Our single weakly positive result was obtained from an air volume of 10 m 3 while using absorption solution as the collection medium, and no positive samples were detected when the air volume was less than 10 m 3 . Therefore, it appears that the airborne concentration of SARS-CoV-2 was very low in our studied hospital. In summary, the study data strongly imply that toilets may be high-risk areas in hospitals with COVID-19 patients and emphasize the importance of hygiene in both private and public toilets. The strong need for hand and environmental hygiene as an intervention for COVID-19 transmission is also indicated. Our study had some limitations. Due to the possibly strong infectivity of this new virus, the sampling operative was subject to the requirements for quarantine and the use of inconvenient full PPE, which might have affected the sampling operation. Moreover, access was provided only to the rooms of patients with mild symptoms. Furthermore, the number of collected air samples was small. Journal Pre-proof Table 1 . Summary of samples collected on the three sampling dates in the four isolation rooms and other areas in the airborne infectious-disease zone. Rooms containing a patient whose throat swabs were all positive on a given day (Table S1) Table 2 . Statistical significance of the positive results for toilet-related or other surfaces in isolation rooms containing at least one patient with all-positive throat swabs before and/or after the sampling. Escalating infection control response to the rapidly evolving epidemiology of the coronavirus disease 2019 (COVID-19) due to SARS-CoV-2 in Hong Kong SARS-CoV-2 from faeces to wastewater treatment: What do we know? A review Microbiological hazards of household toilets: droplet production and the fate of residual organisms First case of 2019 novel coronavirus in the United States Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong Vital surveillances: the epidemiological characteristics of an outbreak of 2019 novel coronavirus diseases (COVID-19)-China SARS pneumonia: a prospective study Association of viral load with serum biomarkers among COVID-19 cases Clinical characteristics of 138 hospitalized patients with 2019 novel coronavirus-infected pneumonia in Wuhan WHO. 2020. Coronavirus disease 2019 (COVID-19) Situation Report -162 Report of the WHO-China joint mission on coronavirus disease 2019 (COVID-19) Severe acute respiratory syndrome beyond Amoy Gardens: completing the incomplete legacy Fecal specimen diagnosis 2019 novel coronavirusshedding routes Isolation of 2019-nCoV from a stool specimen of a laboratory-confirmed case of the coronavirus disease 2019 (COVID-19) Physical factors that affect microbial transfer during surface touch station: below air-supply inlet (air) 24. nursing station: below air-supply inlet The authors are grateful to the many field workers and hospital staff who helped to collect data and provided support for our field measurements in the hospital during the most challenging period of their work. This work was partially supported by the National Natural The funding bodies had no involvement in the study design; the collection, analysis, and interpretation of data; the writing of the report; and the decision to submit the paper for publication. The authors are grateful to the many field workers and hospital staff who helped to collect data and provided support for our field measurements in the hospital during the most Ding wrote the first draft of the paper, and H. Qian, H. Yen, and T. Miao contributed to the major revision. All the other authors contributed to the revision. The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.All the authors approved the submitted version and have agreed to be personally accountable for their own contributions.The corresponding authors also confirm that they had full access to all the data in the study and hold the final responsibility for the decision to submit for publication.