key: cord-1022376-d5mmeu96 authors: Christoff, A. P.; Cruz, G. N. F.; Sereia, A. F. R.; Boberg, D. R.; de Bastiani, D. C.; Yamanaka, L. E.; Fongaro, G.; Stoco, P. H.; Bazzo, M. L.; Grisard, E. C.; Hernandes, C.; de Oliveira, L. F. V. title: Swab pooling for large-scale RT-qPCR screening of SARS-CoV-2 date: 2020-09-05 journal: nan DOI: 10.1101/2020.09.03.20187732 sha: d38b8de017ed203ed78b379b5d93232d5f32db78 doc_id: 1022376 cord_uid: d5mmeu96 Pool testing has been proposed as an alternative for large-scale SARS-CoV-2 screening. However, dilution factors proportional to the number of pooled samples have been a source of major concern regarding its diagnostic performance. Further, sample pooling can lead to increased laboratory workload and operational complexity. Therefore, pooling strategies that minimize sample dilution, loss of sensitivity, and laboratory overload are needed to allow reliable and large-scale screenings of SARS-CoV-2. Here, we describe a pooling procedure in which nasopharyngeal swabs are pooled together at the time of sample collection (swab pooling), decreasing laboratory manipulation and minimizing dilution of the viral RNA present in the samples. Paired analysis of pooled and individual samples from 613 patients revealed 94 positive individual tests. Having individual testing as a reference, no false-positives or false-negatives were observed for swab pooling. A Bayesian model estimated a sensitivity of 99% (Cr.I. 96.9% to 100%) and a specificity of 99.8% (Cr.I. 99.4% to 100%) for the swab pooling procedure. Data from additional 18,922 patients screened with swab pooling were included for further quantitative analysis. Mean Cq differences between individual and corresponding pool samples ranged from 0.1 Cq (Cr.I. -0.98 to 1.17) to 2.09 Cq (Cr.I. 1.24 to 2.94). Overall, 19,535 asymptomatic and presymptomatic patients were screened using 4,400 RT-qPCR assays, resulting in 246 positive patients (positivity rate 1.26%). This corresponds to an increase of 4.4 times in laboratory capacity and a reduction of 77% in required tests. Finally, these data demonstrate that swab pooling can significantly minimize sample dilution and sensitivity issues commonly seen in its traditional counterpart. Therefore, swab pooling represents a major alternative for reliable and large-scale screening of SARS-CoV-2 in low prevalence populations. CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. Finally, these data demonstrate that swab pooling can significantly minimize sample dilution and sensitivity issues commonly seen in its traditional counterpart. Therefore, swab pooling represents a major alternative for reliable and large-scale screening of SARS-CoV-2 in low prevalence populations. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint The COVID-19 pandemic, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has dramatically impacted public health worldwide in this year of 2020 1,2 . Rapid identification and isolation of infected individuals is essential, but it can be particularly challenging given the infectious potential of both asymptomatic and presymptomatic cases 3, 4 . In this scenario, massive population SARS-CoV-2 testing is an urgent need to allow the isolation of infected individuals and, ultimately, the pandemic control. The most sensitive and recommended test is based on the RT-qPCR method, which detects an active infection through the identification of the viral RNA in nasopharyngeal samples [5] [6] [7] [8] . However, several limitations have hampered large-scale population screenings using RT-qPCR, mainly related to the worldwide shortage of supplies and their relatively high cost. To overcome these limitations and scale-up testing capability, some research groups have proposed pooling samples for testing, in which several individuals are simultaneously analyzed using a single test 9-15 . In the many ways that pool testing was proposed so far, all of them are based on individual sample mixing by the laboratory (sample pooling). This procedure involves substantial sample manipulation, leading to operational challenges and, more importantly, to substantial dilution of viral RNA present in any of the pool samples. Such a dilution effect directly impacts the analytical sensitivity of the RT-qPCR assay, potentially leading to reduced diagnostic sensitivity 9 . Here, we describe a pooling procedure in which nasopharyngeal swabs are pooled together at the time of sample collection (swab pooling), decreasing laboratory manipulation and minimizing dilution of the viral RNA present in the sample. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint A retrospective study was performed using de-identified results from nasopharyngeal samples subjected to RT-qPCR-based SARS-CoV-2 testing from May 5 th to July 31 st , 2020. Sample collection was performed focusing on low-prevalence COVID-19 populations (e.g. asymptomatic or presymptomatic individuals). A total of 45 pool samples and their 613 corresponding individual samples were analyzed in parallel to assess correspondence between individual and pool qualitative results, i.e., individual samples were tested regardless of the results from their corresponding pools. Further, 18,922 additional patients were tested using swab pooling, corresponding to 1,344 pools. Among these, only positive pools had their respective individual samples tested. Individuals from negative pools were considered negative for SARS-CoV-2 RNA detection. Comparison of paired cycle quantification (Cq) values from all positive samples obtained was carried out to assess potential quantitative biases due to swab pooling. This study was approved by the Hospital Israelita Albert Einstein Ethics Committee (number 36371220.6.0000.0071).The patient informed consent was waived off by the ethics committee as the research was performed on de-identified, anonymised samples. Nasopharyngeal samples were collected by trained healthcare professionals using nylon flocked swab, stored in tubes containing sterile saline solution and submitted to laboratory processing within a maximum of 48h after sample collection. For the swab pooling method, two swabs were collected from the same individual ( Figure 1 ). The first swab, collected through one nostril, was stored in an individual tube containing 3 mL of saline solution. A second swab, collected from the second nostril, was stored in a pool tube containing 5 mL of saline solution. As a general rule, each pool tube was allowed to contain up to 16 swabs, from 16 different patients, collected apart within a maximum of 1h. In this way, the pooling of swabs is performed at the time of sample collection, dismissing further manipulation, mixing and dilution of the samples by the . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint laboratory. When a given pool tested positive, all the corresponding individual samples were also tested to identify the infected patients. If a pool yielded a negative result, all individuals within that pool were considered negative for SARS-CoV-2 RNA detection. RNA isolation was performed from nasopharyngeal samples using guanidine thiocyanate lysis solution followed by magnetic beads capture and purification (BiomeHub, Brazil). Samples were eluted in 40 µL of RNAse-free water. RNA reverse transcription (RT) was performed using SupesScript TM IV (Invitrogen, USA) and random hexamers, according to the manufacturer instructions. Real-Time PCR detection of SARS-CoV-2 was performed using the following genetic markers: a region of the gene encoding the viral envelope protein (E) with P1 probe and the RNA-dependent RNA polymerase gene (RdRp) with P2 probe for discriminatory assay, as described in the Charité-Berlin protocol 8,16. Also, data from the detection of the surface glycoprotein gene (S) using SYBR Green intercalating fluorophore as previously described 17 All statistical analyses were performed using R statistical software (v. 3.6.3) 18 Concordance between pool and individual tests was determined by considering their corresponding qualitative results, i.e., a test was considered concordant if the individual result matched . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint the result from its corresponding pool. Among positive tests, we quantified the mean Cq difference between individual samples and their corresponding pools. We employed a Bayesian hierarchical model with patient-specific intercepts as follows: where Pool i is an indicator variable which equals 1 when the i th observation is from a pool sample and 0 otherwise. The E i and RdRp i variables adjust for variation in the genetic marker used for the RT-qPCR assay. In these settings, the population-level intercept α represents the average Cq value for an individual test using the S gene, whereas the patient-specific intercept α patient[i] accounts for patient-to-patient variability. The β . coefficients allow quantification of mean Cq differences between individual and pool tests across different genetic markers. We set weakly informative priors for all parameters. Results were reported as posterior means and 95% credible intervals. For the sample dilution in swab pooling experiment, the same model as in (1) was employed, except that varying intercepts varied with inoculating samples instead of with patients; also, only E and RdRp genes were used. Credible intervals for proportions were obtained using a Beta(1, 1) prior for the binomial likelihood. Observed correlations were reported as Spearman's rank correlation as well as Pearson's correlation coefficient. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint In a laboratory experiment, 16 In Figure 2B we show the expected slopes (ΔCq) in RT-qPCR amplifications with variable amplification efficiencies and considering different dilution scenarios. In sample pooling, the dilution factor is equal to the number of individual samples within a pool, yielding expected mean Cq differences of at least 3.32 Cq and as high as 7.37 Cq depending on the number of pooled samples and the amplification efficiency. For swab pooling, on the other hand, the dilution factor is kept fixed at 1.67 so that the expected variation due to dilution alone is constrained between 0.73 and 1.08 Cq. To investigate any loss of diagnostic sensitivity due to swab pooling, we analyzed individual and Figure 3D . Further analysis of Cq variation is performed in the next section. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint Qualitatively, we did not observe any positive individual test paired with a negative pool, i.e., no false-negatives due to swab pooling. In fact, we observed complete agreement (100%) between qualitative results from the pool and individual paired samples. Hence, we employed a simple betabinomial model with flat priors on performance estimates that would otherwise reach 100%. Having individual testing as a reference, the current data supports a sensitivity of 99% (95% Cr.I. 96.9% to 100%) and a specificity of 99.8% (95% Cr.I. 99.4% to 100%) for the swab pooling procedure, indicating evidence of strong similarity in diagnostic performance. To investigate any biases in quantitative results, we included data from additional 1,344 pools and their respective individual tests. In total, 19,535 patients (1,389 pools) were screened using the swab Figure 4B ). To estimate the Cq variation due to swab . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint pooling, we assigned to each patient the Cq value from their individual test and the Cq value from their respective pool. Using a hierarchical model with patient-specific intercepts, we estimated the mean Cq difference between individual tests and their corresponding pools for each genetic marker ( Figure 5 ). For the S gene (94 patients), the mean Cq difference was estimated to be 0. Pool testing has gained importance to fight the COVID-19 pandemic, as challenges involving cost and logistics are at the core of shared struggles to promote large-scale screenings worldwide 10 . Traditional pooling methods proposed 9-15 rely on the combination of multiple individual samples prior to RNA extraction or RT-qPCR, leading to a dilution factor directly related to the number of samples in the pool 9,11-15 . This dilution effect has been of major concern over the diagnostic performance of pool testing procedures 26 . Here, we report a pooling strategy that readily minimizes such an effect and enables largescale screening for SARS-CoV-2. Assessing data from 19,535 screened patients, swab pooling and individual testing showed hardly distinguishable performances both qualitatively and quantitatively. With complete agreement between paired qualitative results from 613 patients, the presented data indicates evidence of strong similarity in diagnostic sensitivity and specificity. We did not observe a clear correlation between pool Cq values and number of positive individuals within the pools, as previously suggested considering other pooling methods 14 . Also, the correlation between Cq values from individual tests and their corresponding pools seems to be stronger for pools with no more than two positive individuals. This is mainly reflecting the potentially wide range of individual Cq values for samples composing a single pool. Although we do use a larger volume for swab pooling (5 mL of saline solution versus 3 mL in individual tubes), the corresponding dilution factor of 1.67 will lead to an expected mean increase of 1.08 Cq even under sub-optimal amplification efficiencies. In a laboratory-controlled experiment, we did not . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint detect clear differences due to dilution alone, with point estimates from 0.43 to 0.61 Cq. In practice, observational data from 246 positive patients generated point estimates of mean Cq differences between individual tests and their corresponding pools ranging from 0.1 to 2.09 Cq. While such values are hardly significant in terms of analytical sensitivity, the expected counterparts for traditional pooling would range from 3.3 to 5 Cq under optimal amplification conditions. This range corresponds to dilution factors from 10 to 32, when equivolumetric pools from 10 to 32 samples, respectively, are formed post-collection by the laboratory as traditionally proposed 9,11,13,15 . In a worst-case scenario for swab pooling, a mean Cq difference of 2.94 Cq (RdRp gene, upper limit of 95% credible interval) would still be considerably lower than the expected differences for sample pooling with 10 samples and perfect amplification efficiency. Nonetheless, there is always a limitation towards samples with Cq's higher than 35, in which case mean differences as small as 1 Cq could still result in false-negative tests regardless of the pooling strategy. Operationally, the major difference between swab pooling and traditional methods regards sample collection: while in swab pooling we combine multiple swabs in the same tube at the time of sample collection, traditional strategies pool equal volumes from individually collected samples. Beyond dilution, the latter methodology adds complexity to laboratory operations and may lead to increased workload to already saturated laboratory facilities. Traditional pooling requires significant sample manipulation with a risk of contamination and even sample exchange during the laborious pooling process. On the other hand, collecting two swabs from the same patient can be operationally trivial. While one swab goes into the pooling tube, the other one will only be processed by the laboratory if the pool tests positive. A critical step, this sample collection process can still represent an important limitation of swab pooling as it can cause variation between pooled and individual swabs. In this study, we detected 12 pools with positive results but no positive associated individual test. Of these, 8 pools were associated with two specific collection events (4 pools collected each day). Thus, it is likely that such inconsistencies are attributable to the sample collection process. Still, these cases represented 0.86% of all 1,389 tested pools. Notably, the proper training of sample collection staff represents a cheaper and easier-toimplement alternative to increased laboratory complexity. Any laboratory capable of routine processing . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint of diagnostic samples for SARS-CoV-2 can also perform swab pool analysis using the same detection methods and infrastructure already in use. Using swab pooling during sample collection, laboratories in which traditional pooling is currently unfeasible become readily able to contribute to large-scale screenings. Swab pooling, therefore, represents a gain in operational performance for reliable testing of SARS-CoV-2 at scale. As it is wellknown, however, any pooling strategy only boosts testing capability for low positivity rates 27 . Swab pooling does not address this matter and is, therefore, suitable for screening populations a with low expected prevalence of COVID-19. The data in the present study comes from the application of swab pooling in asymptomatic or presymptomatic populations, yielding a 1.26% positivity rate. The proposed method was used with pools containing a majority of 16 individuals, but the optimum pool size can be determined by each laboratory during internal validation. Pools with 8, 10, 16, or even 32 swabs may be desirable depending on local epidemiological status and target populations. Upon validation, swab pooling may be applied to any reasonable pool size traditionally proposed to optimize testing scale. Here, over 19,500 patients were screened using approximately 4,400 RT-qPCR assays, corresponding to an increase of 4.4 times in laboratory capacity and a reduction of 77% in the total of required tests. Finally, identification of infected patients is essential to contain the spread of SARS-CoV-2. This has been hampered by the fact that several people carrying the virus remain asymptomatic or presymptomatic 4,28 . Thus, massive and sensitive testing of asymptomatic and presymptomatic individuals is of utmost importance to fight the COVID-19 pandemic, especially at the moment in which the world attempts to resume economic and social activities. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint CONCLUSION Pool testing is a major alternative for large-scale screening of SARS-CoV-2 in low prevalence populations. Here, we demonstrate that the swab pooling minimizes sample dilution, can be as sensitive as individual testing and reduces laboratory workload. A total of 77% of tests were saved in the screening of 19,535 asymptomatic or presymptomatic patients. We would like to thank all BiomeHub, HIAE, and UFSC staff who were involved in all stages of sample collection, laboratory processing, and results discussion. We are grateful for their countless efforts to persist in high-quality research during such difficult times for science in our country, especially during the COVID-19 pandemic. Conflict of interest disclosures: all authors from BiomeHub are currently full-time employees of this research and consulting company specialized in microbiome biotechnologies. BiomeHub funded the study design, analysis and data submission for publication. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . https://doi.org/10.1101/2020.09.03.20187732 doi: medRxiv preprint . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted September 5, 2020. As amostras para triagem, que compreendem em grupos de até 16 indivíduos, são montadas no momento da coleta, ou seja, 1 (um) swab nasofaríngeo é coletado em uma narina e acondicionado em frasco do grupo Caso exista a necessidade de identificação do indivíduo positivo, dentro de um grupo positivo, é necessário a coleta de um segundo swab nasofaríngeo, acomodado de forma individual para posterior diagnóstico. Pool dividual As amostras para triagem, que compreendem em grupos de até 16 indivíduos, são montadas no momento da coleta, ou seja, 1 (um) swab nasofaríngeo é coletado em uma narina e acondicionado em frasco do grupo Caso exista a necessidade de identificação do indivíduo positivo, dentro de um grupo positivo, é necessário a • Como o método não dilui, e sim concentra as cargas virais, se existir mais de um indivíduo infectado, a soma das cargas virais dos indivíduos aumentará a sensibilidade do processo de triagem; http://biome-hub.com © BiomeHub. All Rights Reserved. Individual em uma narina e acondicionado em frasco do grupo Caso exista a necessidade de identificação do indivíduo positivo, dentro de um grupo positivo, é necessário a coleta de um segundo swab nasofaríngeo, acomodado de forma individual para posterior diagnóstico. COVID-19: a new challenge for human beings Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and corona virus disease-2019 (COVID-19): the epidemic and the challenges Temporal dynamics in viral shedding and transmissibility of COVID-19 Clinical Course and Molecular Viral Shedding Among Asymptomatic and Symptomatic Patients With SARS-CoV-2 Infection in a Community Treatment Center in the Republic of Korea Analytical sensitivity and efficiency comparisons of SARS-CoV-2 RT-qPCR primer-probe sets Interpreting Diagnostic Tests for SARS-CoV-2 Diagnostic strategies for SARS-CoV-2 infection and interpretation of microbiological results Pooled RNA sample reverse transcriptase real time PCR assay for SARS CoV-2 infection: A reliable, faster and economical method Pooling of SARS-CoV-2 samples to increase molecular testing throughput Detection of 2019 novel coronavirus (2019-nCoV) by realtime RT-PCR A familial cluster of pneumonia associated with the 2019 novel coronavirus indicating person-to-person transmission: a study of a family cluster R: A Language and Environment for Statistical Computing. R Foundation for Statistical Computing Welcome to the Tidyverse brms : An R Package for Bayesian Multilevel Models Using Stan A Probabilistic Programming Language ggplot2" Based Publication Ready Plots RColorBrewer: ColorBrewer Palettes. R Package Version 1.1-2 The Composer of Plots Simulation of Pool Testing to Identify Patients With Coronavirus Disease 2019 Under Conditions of Limited Test Availability Multi-Stage Group Testing Improves Efficiency of Large-Scale COVID-19 Screening The implications of silent transmission for the control of COVID-19 outbreaks