key: cord-1018272-gpnqscb0 authors: Hoek, Rogier AS; Verschuuren, Erik AM; de Vries, Rory D; Vonk, Judith M.; van Baarle, Debbie; van der Heiden, Marieke; van Gemert, Johanna P; Gore, Edmund J; Niesters, Hubert GM; Erasmus, Michiel; Hellemons, Merel E.; Scherbeijn, Sandra MJ; Wijbenga, Nynke; Mahtab, Edris A.F.; GeurtsvanKessel, Corine H.; Buter, Coretta Van Leer title: High Torque tenovirus (TTV) load before first vaccine dose is associated with poor serological response to COVID-19 vaccination in lung transplant recipients date: 2022-03-16 journal: J Heart Lung Transplant DOI: 10.1016/j.healun.2022.03.006 sha: fbdce77edd079a1f30ffd33a0bffbc3205916dd6 doc_id: 1018272 cord_uid: gpnqscb0 BACKGROUND: : Serological responses to COVID-19 vaccination are diminished in recipients of solid organ transplants, especially in lung transplant recipients (LTR), probably as result of immunosuppressive treatment. There is currently no marker of immunosuppression that can be used to predict the COVID-19 vaccination response. Here, we study whether torque tenovirus (TTV), a highly prevalent virus can be used as an indicator of immunosuppression. METHODS: : The humoral response to the mRNA 1273 vaccine was assessed in 103 LTR, who received a transplant between 4 and 237 months prior to vaccination, by measuring Spike (S)-specific IgG levels at baseline, 28 days after first, and 28 days after the second vaccination. TTV loads were determined by RT-PCR and Pearson's correlation coefficient was calculated to correlate serological responses to TTV load. RESULTS: : Humoral responses to COVID-19 vaccination were observed in 41/103 (40%) LTR at 28 days after the second vaccination. 62/103 (60%) were non-responders. Lower TTV loads at baseline (significantly) correlated with higher S-specific antibodies and a higher percentage of responders. Lower TTV loads also strongly correlated with longer time since transplantation, indicating that participants with lower TTV loads were longer after transplantation. CONCLUSIONS: : This study shows a better humoral response to the SARS-CoV-2 vaccine in subjects with a lower TTV load pre-vaccination. In addition, TTV load correlates with the time after transplantation. Further studies on the use of TTV load in vaccination efficacy studies in immunocompromised cohorts should provide leads for the potential use of this marker for optimizing vaccination response. Since the first reports of infections with SARS-CoV-2 at the end of 2019, a worldwide pandemic of corona virus disease 2019 (COVID-19) has followed affecting millions worldwide(1). Factors associated with COVID-19 related mortality were older age, obesity, recent malignancy and chronic respiratory, cardiac and renal disease (2, 3) . Solid organ transplant recipients (SOTR) are also at increased risk for severe COVID-19 because of their immunosuppressed state (4) (5) (6) (7) . Vaccination of transplant recipients against COVID-19 is recommended by international guidelines (8), although these patients were initially excluded from vaccine trials. Post-licensure vaccination studies in SOTR reported vaccination was safe, but low serological responses were reported. Seroconversion rates range from 0-36% in Lung transplant recipients (LTR) (9) (10) (11) compared to >90% for the mRNAvaccines in the general population (12) . This vaccination response in LTR is significantly lower that what was demonstrated for recipients of liver, kidney and heart transplants (9) , and can be explained by the fact that compared to other SOTR, LTR receive higher levels of immunosuppression. LTR also have higher mortality due to COVID-19 than other SOTR, because of infection of the allograft itself, advanced age of the recipient and increased intensity of immunosuppression (13) (14) (15) (16) . No marker exists which can be used assess the immunosuppressed state of SOTR, but in recent years Torque tenovirus (TTV) has been under investigation as a potential surrogate (17) . TTV is a single stranded DNA virus, with high prevalence worldwide (18) . TTV has not been shown to cause pathology. (18, 19) . Studies have demonstrated an association between the amount of detectable TTV in blood and graft survival after solid organ transplantation (SOT) (20, 21) . TTV is currently also being investigated as a marker for immunosuppression and immune reconstitution in stem cell transplantation recipients and in HIV infection (19, (22) (23) (24) . In SOTR, TTV loads increase rapidly after transplantation with the induction of immunosuppression, reaching a plateau phase after 3 to 6 months (25, 26) . The TTV load in this plateau phase is higher for LTR that for recipients of other organs (27) (28) (29) (30) . In all SOTR, low TTV levels were shown to predict rejection episodes (27) (28) (29) . In contrast, high immunosuppression levels, as reflected in high TTV loads, potentially carry a risk for infection (20, 21, 26, 27, 30) . Here, we hypothesize that the TTV load may be a predictor of the humoral response to the COVID-19 vaccine in LTR. To test this hypothesis, we determined the pre-vaccination TTV load in 103 LTR vaccinated with the mRNA-1273 (Moderna, USA) COVID-19 vaccine, and determined if the serological response at 28 days after the second vaccine dose was associated with the baseline TTV load. The study protocol was approved by the UMCG Participants reported adverse events for seven days after each vaccination dose, noting local symptoms (pain, swelling and redness), as well as systemic symptoms (fever, gastro-intestinal symptoms, headache, fatigue and myalgias). Participants recorded for how many days the symptoms lasted and how severe they were, ranging from not interfering with daily activities to preventing performing daily activities. Lung function was measured at each study visit and participants measured their lung function using home peak flow measurement or home spirometry at least once after each visit, or more frequently in case of symptoms. Participants were asked if they had been diagnosed with COVID-19 prior to each study visit. Humoral immune responses to vaccination were measured with a quantitative assay directed against the SARS CoV-2 Spike (S) protein (Liaison SARS CoV-2 TrimericS IgG assay, DiaSorin, Italy), with a lower limit of detection of 4.81 BAU/ml. The assay was performed following the manufacturer's instructions. Values >= 10 BAU/ml were considered reactive and values of >= 300 BAU/ml were shown to correlate with presence of neutralizing antibodies, based on in-house validation studies and harmonization between serological methods used in collaborative study teams (31) . Antibodies against the viral Nucleocapsid protein (N) were measured on an Abbott Architect instrument using the Abbott SARS-CoV-2 IgG assay following the manufacturer's instructions (32) . Qualitative results and index values were used for analysis, with the cut-off for positive set at 1.4 S/CO. DNA extraction from serum samples, and amplification of DNA was performed as previously described (21, 28) . In brief, DNA extraction was carried out using the eMAG Nucleic Acid Extraction System (BioMerieux, Marcy, France). For DNA amplification and quantification, the Argene R-Gene TTV quantification kit (BioMerieux, Marcy, France) was used on an Applied Biosystems 7500 (Thermo fisher, Waltham, MA, USA) according to the manufacturer's instructions. The R gene assay is designed to detect the majority of TTV genotypes (1, 6, 7, 8, 10, 12, 15, 16, 19, 27 and 28) . Due to limited sample volumes, 100 µL, a 1 in 2 dilution using DMEM, was performed prior to sample extraction (ThermoFisher, Waltham, MA, USA). Results are expressed in log copies/ml. SPSS version 23 was used for statistical analysis. Serological responses below the lower limit of detection were set to 4.81 BAU/ml. Serological responses at different time-points were compared by paired T-tests on log-transformed data. Differences in serological responses among quartiles of TTV load were compared by independent T-tests on log-transformed data. Pearson's correlation coefficient was calculated to correlate serological responses to TTV load and TTV load to time since transplantation (all data were log-transformed). A linear regression line was calculated for both correlations. To compare baseline data among groups, we used Mann-Whitney-U tests for continuous data and chi-square tests for categorical data. Two-sided exact P-values are reported; a P-value < 0.05 was considered to be statistically significant. To investigate the independent association of TTV load, age and time since transplantation with vaccine response a logistic regression was performed including these 3 variables. Since age was not linearly related to serological response, age was included as a categorical variable (i.e. < 35 years, 35-50 years, 50-65 years, ≥ 65 years). In a second logistic regression model, the use of immunosuppressive medication was added to investigate the predictive value of immunosuppressive medication use on vaccine-response. Baseline characteristics of the 103 participants of the study are depicted in table 1 Limited side-effects and reactogenicity of vaccination were observed. The most commonly reported symptom was tiredness for one day only (25% of participants), followed by muscle pain (16%) and headache (13%) for one day. Three individuals experienced local symptoms for two days. Symptoms were mild, responsive to simple pain relief, and did not interfere with daily activities in any case. No significant changes in lung function were observed as a result of vaccination. One participant who did experience reduction in lung function during the follow-up period was diagnosed with an unrelated infection. At baseline, all participants tested negative for antibodies against N. One of the participants tested low-positive for antibodies against S prior to vaccination, but this participant was included for further analysis. At the time of the second vaccination dose, 28 days after the first dose, seventeen participants (16.5%) had developed detectable antibodies against S (median 20 BAU/ml, range 11-473). At 28 days after the second vaccine dose, 41 participants (40%) had detectable antibodies against S-protein (median 55 BAU/ml, range 10-8540 BAU/ml). These 41 participants were all considered responders. Sixty-two participants who did not develop detectable antibodies above 10 BAU/ml were considered non-responders. None of the participants developed antibodies against N in this period. Only 13 (12.6%) participants had antibody levels exceeding 300 BAU/ml (figure 1). Non-responders to the vaccine were more likely to have received immunosuppression containing MMF. In the groups of responders, 71% (n=29) received MMF and in the non-responder group this was 95% (n=59; p=0.001) (table 1). Use of azathioprine was associated with good serological response (p=0.003). Seventeen individuals with CF were included, 12 (71%) of whom showed a serological response to the vaccine. In contrast, 46 individuals with obstructive lung disease were included, of whom only 12 (26%) showed serological response. LTR with CF were significantly SARS-CoV-2-specific antibody titers in response to the mRNA-1273 vaccination correlated with TTV loads at baseline. Antibody levels were higher in patients with lower TTV viral loads (R between log(TTV) and log(SARS-CoV-2 antibodies) = -0.322, R 2 = 0.104, p = 9.05*10 -4 ). (Figure 2A ). For analysis of patient characteristics associated with TTV loads, participants were divided in 4 groups of 25-26 participants based on TTV load. The percentage of responders was higher in patient groups with lower TTV loads. In the group with the highest TTV levels (>6.5 log copies/ml (n=26), there were only two serological responders (7.7%). In the group with the second highest TTV loads (between 5.13 and 6.50 log copies/ml), there were 10 serological responders (40%). In the group with TTV levels between 3.78 and 5.13 log copies/ml, there were 14 responders (53.8%), and in the group with the lowest TTV levels (<3.78 log copies/ml) which included the six participants with undetectable TTV , there were 15 responders (57.7%) (p=7.76*10 -4 ) ( Figure 2B) . Five of six patients (83%) with undetectable TTV loads at baseline developed an antibody response to the vaccine. TTV loads correlated strongly with time since transplantation. The TTV loads were lower in individuals who were longer after transplantation (R between log(time since transplantation) and log(TTV) = -0.428, R 2 = 0.183, p < 6.46*10 -6 ) (figure 3). Time since transplantation was the shortest 17.5 (11-57.5) in the group with the highest TTV loads (>6.50 log copies/ml) . The group with the longest time since transplantation (97 months (57-159)) also had the lowest TTV loads (<3.78 log copies/ml) (p=2.86*10 -5 ). Tacrolimus through levels and age of the participants were not associated with TTV load (table 2) . Multivariate logistic regression analysis was performed to assess the impact of TTV load at baseline, time since transplantation and age on humoral vaccination response. The results show that both TTV and age ≥ 50 years are significantly associated with a lower odds of being a (low) responder. Time since transplantation is not independently associated with vaccine-response (table 3A) . Furthermore, logistic regression analysis aiming to investigate the impact of MMF and azathioprine treatment on the responder status of the patient was performed, showing that the use of MMF was associated with a lower odds of being a (low) responder, whereas the use of azathioprine was not (table 3B) . Here, we studied the correlation between the serological response to the mRNA 1273 COVID-19 vaccination and baseline TTV loads. We observed that a low number of LTR produce antibodies to the S protein after vaccination (40% after two vaccinations), similar to 35% responders that Hallett et al found in a study of equal size (33) . Only 13 participants (13%) developed IgG levels >300 BAU/ml, a level above which neutralizing antibody activity can usually be demonstrated (31) . Several studies have now reported that LTR have lower responses to the COVID-19 vaccine compared to recipients of liver, kidney and heart transplants (9, 34) . This can be explained by the fact that compared to other SOTR, LTR receive higher levels of immunosuppression. No marker exists which can be used assess the immunosuppressed state of SOTR, but in recent years TTV has been under investigation as a potential surrogate. As such, studies have found higher TTV loads in LTR than in recipients of other SOTs (27) (28) (29) (30) . In this study we found that poor serological responses to COVID-19 vaccination are significantly associated with baseline TTV loads. Our study shows a remarkably wide range of TTV loads, from negative to 10 9 copies/ml. Higher S-specific antibody titers and responder rates are found in individuals with lower TTV loads. However, even in the lowest TTV level group of < 3.78 log copies/ml there were only 57.7% responders, which is a response rate far below that in populations with no underlying illness (12) . When comparing immunosuppression, we found that the use of MMF was associated with less serological responses, which was already shown by several other studies (31, 33) . However, the use of MMF was not clearly associated with TTV load. After adjustment for MMF use, we did not find that azathioprine was associated with response rates, although both MMF and azathioprine belong to the same class of antirejection drugs. However, the number of patients receiving azathioprine was small in our cohort and azathioprine was only used in patients not receiving MMF. Possibly, immunosuppressive agents, even those with a comparable effect on antirejection activity, have diverse effects on the vaccination response. Furthermore, factors unrelated to immunosuppression such as age, may also influence the immune response. In the logistic regression analysis we show that higher age correlated with a lower response to the vaccine. In our study, we show that patients with CF had higher response rates, and patients with obstructive lung diseases had lower response rates to vaccination. However, LTR who had CF were significantly younger than those with obstructive lung disease, which suggests that the differential responses may be attributable to the age difference between the groups. Interestingly, TTV loads correlate with time since transplantation. We show that a longer time since transplantation was associated with both better serological response to the COVID-19 vaccine, and with lower TTV load. The association between time after transplantation and vaccination response was shown by others in LTR as well as in recipients of other types of organs (9, 31) . We now found that that time after transplantation correlates strongly with TTV load. By logistic regression analysis we show that the TTV load is an important predictor of serological response, but that time since transplantation is not independently associated with vaccination response. High TTV loads in this study nevertheless are found predominantly in the first months to years after transplantation, and patients who have received lung transplants several years before, tend to have lower TTV. There are only few studies which have investigated the kinetics of TTV loads. TTV levels are found to increase after transplantation, and a plateau phase is reached after 3-6 months in these studies (25, 26) . If no acute rejection events occur, immunosuppression is stable after this period, and the thought is that TTV levels are stable as well. However, the existing data investigating TTV levels years after transplantation is not based on longitudinal observations and is inevitably biased towards SOTR who are still alive at that time. Although our study was not set up as a long term/longitudinal TTV study, our data may suggest that TTV levels vary over time. The high TTV loads observed in the first few years after transplantation might result from long-term effects of induction therapy, and TTV load may decrease over time. Another explanation for the finding of lower TTV loads years after transplantation is that patients with lower TTV loads are more likely to be alive at that time. Although this has not been established for LTR, in renal transplant recipients it was shown that survival was lower in patients with high TTV loads (21) . If indeed LTR with high TTV loads have lower survival rates, this could mean that the favorable vaccination response in patients longer after transplantation is not necessarily associated with time, but that patients who are more affected by the immunosuppression and respond less well to vaccination have a lower chance of survival beyond a certain number of years. In conclusion, this study investigated the serological response to the mRNA1273 vaccine in lung transplant recipients and shows a serological response rate of 40 % after two vaccinations. This study is the first to investigate the association between TTV load and vaccination response. We show a significant association between a lower TTV load and a better serological vaccination response. This finding sheds a different light on the more favorable response found in SOT patients who are longer after transplantation which is consistently found also in COVID-19 vaccine efficacy studies in different transplantation patients. All these studies, including this present study, may be biased toward inclusion of patients with more optimal immunosuppression, resulting in better vaccine response as well as longer survival. Longitudinal, prospective studies investigating TTV loads in transplant recipients looking into graft survival and overall survival in all SOT patients, are therefore recommended. Moreover, the association between TTV load and vaccine response should be investigated in other cohorts of immunocompromised individuals. If the TTV load prior to vaccination is indeed a representative predictor of vaccine response, this could be used as a potential guidance for optimizing vaccination regimens. The authors have no conflicts of interest. This study was made possible by the support of the Netherlands Organization for Health Research and Development (ZonMW). Factors associated with COVID-19-related death using OpenSAFELY Short-term outcomes of COVID-19 and risk factors for progression COVID-19 in solid organ transplant recipients: Initial report from the US epicenter First experience of SARS-CoV-2 infections in solid organ transplant recipients in the Swiss Transplant Cohort Study COVID-19 in solid organ transplant recipients: a singlecenter experience COVID-19 in solid organ transplant: A multicenter cohort study Antibody Response to 2-Dose SARS-CoV-2 mRNA Vaccine Series in Solid Organ Transplant Recipients Immunogenicity of BNT162b2 mRNA COVID-19 vaccine and SARS-CoV-2 infection in lung transplant recipients Serological Response in Lung Transplant Recipients after Two Doses of SARS-CoV-2 mRNA Vaccines. Vaccines (Basel) Efficacy and Safety of the mRNA-1273 SARS-CoV-2 Vaccine COVID-19 in lung transplant recipients COVID-19 in transplant recipients: The Spanish experience COVID-19 in lung transplant recipients Covid-19 in hospitalized lung and non-lung solid organ transplant recipients: a comparative analysis from a multicenter study Torque teno virus: the human virome from bench to bedside Human anelloviruses and the central nervous system Prevalence and Prognostic Significance of Infection with TT Virus in Patients Infected with Human Immunodeficiency Virus The Journal of Infectious Diseases Pre-transplant plasma Torque Teno virus load and increase dynamics after lung transplantation Torquetenovirus Serum Load and Long-Term Outcomes in Renal Transplant Recipients Torquetenovirus Dynamics and Immune Marker Properties in Patients Following Allogeneic Hematopoietic Stem Cell Transplantation: A Prospective Longitudinal Study Torquetenovirus viremia kinetics after autologous stem cell transplantation are predictable and may serve as a surrogate marker of functional immune reconstitution TTV viral load as a marker for immune reconstitution after initiation of HAART in HIV-infected patients Development of a standardized real time PCR for Torque teno viruses (TTV) viral load detection and quantification: A new tool for immune monitoring Early Post-Transplant Torquetenovirus Viremia Predicts Cytomegalovirus Reactivations In Solid Quantification of Torque Teno Virus Viremia as a Prospective Biomarker for Infectious Disease in Kidney Allograft Recipients Torquetenovirus Viremia for Early Prediction of Graft Rejection after Kidney Transplantation Torque teno virus loads after kidney transplantation predict allograft rejection but not viral infection Puchhammer-Stöckl E. Plasma DNA levels of torque teno virus and immunosuppression after lung transplantation The immunogenicity, tolerability and safety of COVID-19 vaccination in patients with chronic kidney disease, on dialysis, or living with a kidney transplant Performance Characteristics of the Abbott Architect SARS-CoV-2 IgG Assay and Seroprevalence in SARS-CoV-2 messenger RNA vaccine antibody response and reactogenicity in heart and lung transplant recipients. JHLT, epub ahead of print Poor humoral and T-cell response to two-dose SARS-CoV-2 messenger RNA vaccine BNT162b2 in cardiothoracic transplant recipients We thank Annemarie Geel, Thea Scholtens, Annika Post and Willie Steenhuis for their assistance in the logistical and administrative management of the participants, and Susanne Bogers en Faye de Wilt for their dataprocessing expertise.