key: cord-1018053-4zh0t9d5 authors: Gordon, J.; Abdullah, O.; Reboulet, R.; Hanson, k.; Sadowski, C.; Rennels, H.; Kuemmerle, S.; Tuttle, R.; Solocinski, K.; Knight, B.; Wilkinson, J.; Macgregor-Skinner, G. title: Assessment of indoor biological air quality at a mass gathering event in an unimproved exhibition facility during the COVID-19 pandemic using a novel air sampling technology. date: 2022-02-28 journal: nan DOI: 10.1101/2022.02.19.22271227 sha: 8f5b0395faa3794a14d25d25531e5c1cdaa5c89a doc_id: 1018053 cord_uid: 4zh0t9d5 The objective was to evaluate the determination of biomarkers of air quality during a mass gathering event at a convention center using a novel air sampling device, AirAnswers(R). This sampler has previously only been used in smaller locations. Here it was run at five crowded locations within the exhibit area for the four days duration of a trade show. The AirAnswers(R) device uses electro-kinetic flow to sample air at high rates and capture bio-aerosols on grounded electrodes in assayable form. Cartridges were removed from the devices and immediately conveyed to the Inspirotec facility in North Chicago, where assays were performed. Biomarkers determined were for allergens and molds previously described for this system. Testing for a new marker, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA was also included. The method was validated by determination of capture efficiency with reference to an impinger sampler in a Class III controlled environment chamber. Average capture efficiency for triplicate runs was 14%. One SARS-CoV-2 positive sample as found at the registration area, which was physically separate from the main exhibit area. Cat allergen Fel d 1was found in four of the locations, dog allergen Can f 1 at two. The airborne biomarker of mold proliferation, (1[->]3)-{beta}-D-Glucan, was above the assay range in all locations. The widespread presence of this mold marker could be accounted for by signs of water leakage. A generic 18S RNA marker for mold was developed and similarly showed the presence of mold in all locations, as was a genus marker for penicillium. A species marker for Cladosporium cladosporioides was in two locations. Species markers for Eurotium amstelodami and Trichoderma viride were each in a single location. The main findings were of the widespread presence of mold markers, and the sporadic appearance of SARS-CoV-2. Masking was recommended but not enforced. The AirAnswers® device for air sampling uses electro-kinetic flow to sample air at high 48 rates, and capture bio-aerosols on the grounded electrodes in assayable form. 49 Published data to date using this system [1] [2] [3] [4] has been for single home locations and in 50 various locations in a school system [5] . Previous measurements have focused on 51 common household allergens and (1→3)-β-D-Glucan, a fungal cell-wall fragment. In this 52 study, the utility is extended to the validation of the measurement of airborne SARS-53 CoV-2. 54 As scientific understanding of the routes of severe acute respiratory syndrome 55 coronavirus 2 (SARS-CoV-2) the causative agent of Coronavirus disease 2019 19) transmission progressed, experts in the field concluded that the main means of 57 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 28, 2022. ; https://doi.org/10.1101 https://doi.org/10. /2022 transmission was via fine droplets in the air [6] . This was based on identification of 58 spreader events from the origin in Hunan, China and subsequent global spread. 59 However, direct measurements of the airborne coronavirus have been limited. 60 Heneghan et al placed online a comprehensive review of work on airborne SARS-CoV-61 2 and showed the need for a standardized validated procedure [7] . All work thus far has 62 been based on limited numbers of observations and no formal validation of methods. 63 Methods that have been applied to attempts to detect airborne SARS-CoV-2 include 64 glass fiber filter [8] , gelatin filters [9] various other kinds of filters [10] , condensate 65 capture [11] [12] [13] [14] , NIOSH vortex sampler [15] [16] [17] electrostatic aerosol to hydrosol [18] , 66 SKC Impinger [19] , personal environmental monitor [20] , Sioutas Cascade Impactor 67 [21] .or bubbling through triazole [22] . One study made use of the AirAnswers® to show 68 presence of airborne SARS-CoV-2 associated with the choir in a high school [5] . Here 69 the measurement is validated in a controlled environmental chamber. After being canceled in 2020, amid the COVID-19 pandemic, the trade show returned in 71 2021, and AirAnswers® devices were placed at five locations within the exhibit area. The facility had been unoccupied for two years, and only one other convention had 73 been held immediately preceding this one. We analyzed air samples for biological 74 agents that included allergens, mold, and SARS-CoV-2 virus. 75 76 77 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted February 28, 2022. ; There were approximately 3500 people registered to attend the meeting. Of these 3500, 94 it is estimated that up to 2500 people may have been in the ballroom at any one time. Masking or distancing were not strictly observed, but evidence of vaccination had been 96 required of participants. Locations in high traffic and/or congregation areas, e.g. meeting . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted February 28, 2022. ; https://doi.org/10.1101 https://doi.org/10. /2022 registration areas, concourses, waiting areas, water stations, etc. were identified as AirAnswers® devices were run for four days for the duration of the trade show. Cartridges containing captured bioaerosol sample were removed from the devices and 3. Validation of SARS-CoV-2 virus capture efficiency. Testing was performed at MRI-Global, an independent research organization, in a 2.5 ft 128 X 3.5 ft 1.5 ft plexiglass Class III biosafety cabinet, total volume about 371 L. USA-129 WA1/2020 strain of virus (BEI Resources, Manassas, VA) was cultivated in Dulbecco 130 Modified Eagles Medium with 5% fetal bovine serum, and penicillin, streptomycin and 131 neomycin. Freshly grown stock at 3.16X10 6 TCID50/mL was injected into the chamber. Test runs were for 30 minutes. The chamber contained triplicate AirAnswers® devices 133 and a Midget Sample Impinger (Ace Glass) as reference method. Devices were placed 134 in the chamber equidistant from the walls with a fan running for 10 minutes prior to run. A collision 6 Jet Nebulizer for aerosol generation, driven by HEPA filtered air, was filled 136 with 10 mL of viral suspension prior to the run. An APS 3221 aerosol particle sizer 137 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 28, 2022. ; https://doi.org/10.1101/2022.02.19.22271227 doi: medRxiv preprint pulled air for 30 seconds at times 0, 10 and 20 minutes, with dynamic particle size 138 range 0.3 to 20 µm. Particle count results are given in Supplementary Data Table S2 Technologies, Thermo Fisher Scientific, and ATCC. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 28, 2022. ; https://doi.org/10.1101/2022.02.19.22271227 doi: medRxiv preprint 167 RESULTS. (1) Allergen at 5 locations in the Convention Center. (2) Fungal presence in the air of Convention Center. All (1→3)-β-D-Glucan results were elevated above the measuring range of the assay 188 (>100 pg/M 3 : Table 2 ). This suggests the extensive presence of mold or residues of 189 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 28, 2022. 195 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 28, 2022. ; https://doi.org/10.1101/2022.02.19.22271227 doi: medRxiv preprint mold in the building. Some water leak was noted in the ceiling above the water station 196 (Location 2), but high values of (1→3)-β-D-Glucan were found in all areas. Therefore, 197 more detailed analysis of mold speciation was undertaken making use of the availability 198 of standard primer and probe sets as used for detecting species for calculation of 199 relative moldiness index (RMI), as provided by Fintech. Table 3 The RMI primer-probe sets are well-established for mold species. Possible mold 212 species may be missed by not being included in the RMI list. We, therefore, designed 213 genus-specific probes and primers that may lead to results with more generality. The 214 genus tests were done on total extract from the electrodes, so that, in addition to 215 spores, any airborne fragments of fungus that included amplifiable DNA or DNA 216 fragments would be included, if present. Results in Table 2 show Aspergillus was 217 detected in the registration desk area, even though no species of aspergillus spores 218 was found. Penicillium was detected at all 5 locations, even though no Penicillium 219 spores had been detected at the species level. This suggests that some undefined 220 Penicillium species spore or fragments was in the air of the entire facility, and that was shedder who either did not go on to visit the exhibition area, or that the air volume in the 234 exhibit was so large that the shed virus was diluted to undetectable levels. This 235 supports results above that a particular mold species may be confined to a relatively 236 limited air space like that around the registration desk. Nevertheless, the occurrence of 237 virus in the air at any location means that it is premature to relax restrictions that are 238 intended to prevent occurrence of spreader events. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 28, 2022. identified as being present in the Convention (Table 3) , Trichoderma viride, one of the 256 zero tolerance molds, was detected along with Cladosporium. Cladosporium, one of the 257 most allergenic molds, was detected in the registration desk area (1). Cladosporium 258 was also located at the AirAnswers booth. For the air to be considered clean, the 259 sources of these molds should be identified and eliminated. It is noteworthy that no single strategy will eliminate the pandemic. Vaccination is never 262 100% effective. Masking and distancing lower the risk, but even masking does not 263 completely eliminate the risk of infection. There is work suggesting that eyes may be a 264 site for viral penetration [27] although eye protection is no longer widely used. For a facility with an existing HVAC system, the cost of replacement or updating will 266 depend on the specific facility. For a facility such as that which is the subject of this 267 work, a more direct way of cleaning the air could be to add mobile air-cleaning devices 268 throughout the facility. An example of a current system is that from Integrated Viral [28]. The area of the Ballroom, which is the subject of the current work, is 85,204 sq ft. 274 We estimate that 6 such units would be required to clean the air of this large space, at a 275 cost of $84,000. This would be the minimal cost to remediate the air during a crowded 276 congress, in the absence of a radical upgrade to the current HVAC system. In contrast, 277 the analysis provided by AirAnswers would cost approximately $5,500. It is a cost-278 effective way of determining whether a more expensive remediation will be required. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 28, 2022. The presence of devices was accepted by organizers and no complaints received. A 280 single measurement of SARS-CoV-2 above detection limits could be the initiation of a 281 spreader event. The present study provides a baseline against which to monitor any 282 future improvements of the air handling system. Karimzadeh et al [29] speculated that 283 approximately 100 particles inhaled are sufficient to trigger an infection. From the 284 concentration of particles measured at the registration desk, 260/L, an infectious dose 285 would be inhaled in approximately 23 seconds, based on a standard breathing rate of 286 70 lpm. However, the PCR assays for SARS-CoV-2 may greatly overestimate the 287 number of infectious particles in the air as non-viable damaged virus or viral fragments. There was no indication that this was a superspreader event as there was no 289 documnted number of actual cases following the event. Spread may have also been 290 mitigated by the organizer's requirement that participants be vaccinated. Nevertheless, 291 this provides a powerful motivation to ensure that indoor air quality should be monitored 292 at mass gathering events especially during a pandemic. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 28, 2022. This work was funded by Inspirotec Inc. 297 We gratefully acknowledge the help of Larry Cooper of The Experience for supporting 298 the facilitation and the execution of this study 299 300 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 28, 2022. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted February 28, 2022. independent runs taken for 10 seconds at times indicated. Note that although particles 381 are rapidly depleted from the chamber due to capture by the three AIrAnswers devices, 382 they are subject to the same environment as the impinger reference sampling device. . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted February 28, 2022. ; https://doi.org/10.1101 https://doi.org/10. /2022 A new patient-operated sampling device for measurement of aeroallergens A simple novel device for air sampling by electrokinetic capture Validation of a novel sampling technology for airborne allergens in low-income 306 urban homes Concurrent measurement of microbiome and allergens in the air of 308 bedrooms of allergy disease patients in the Chicago area. Microbiome Assessment of a Program for SARS-CoV-2 Screening and Environmental 310 Monitoring in an Urban Public School District It Is Time to Address Airborne Transmission of Coronavirus 312 Disease 2019 (COVID-19) SARS-CoV-2 and the Role of Airborne Transmission: Systematic review Evaluating the presence of SARS-CoV-2 RNA in the particulate matters during 317 the peak of COVID-19 in Padua, northern Italy Aerosol and surface contamination of SARS-CoV-2 observed in quarantine 319 and isolation care Exploratory assessment of the occurrence of SARS-321 CoV-2 in aerosols in hospital facilities and public spaces of a metropolitan center in Brazil Viral Load of SARS-CoV-2 in Respiratory Aerosols Emitted by COVID-19 Patients while Breathing, Talking, and Singing. Clinical infectious diseases Direct whole blood analysis by the antigen -326 antibody chemically-delayed dissociation from nanosensors arrays Viable SARS-CoV-2 in the air of a hospital room with COVID-19 patients Rapid and low-cost sampling for detection of airborne SARS-CoV-2 in 331 dehumidifier condensate Bioaerosol Sampling for Severe Acute Respiratory Syndrome Coronavirus 2 333 (SARS-CoV-2) in a Referral Center with Critically Ill Coronavirus Disease 2019 (COVID-19) Patients Clinical infectious diseases : an official publication of the 337 Infectious Diseases Society of America The size and culturability of patient-generated SARS-CoV-2 aerosol Increased survivability of coronavirus and H1N1 influenza virus under electrostatic 341 aerosol-to-hydrosol sampling Investigation of SARS-CoV-2 in hospital indoor air of COVID-19 patients' 343 ward with impinger method. Environmental Science and Pollution Research Tracing surface and airborne SARS-CoV-2 RNA inside public buses and subway 21 Isolation of SARS-CoV-2 from the air in a car driven by a COVID patient with 348 mild illness A safe and effective sample collection method for assessment of SARSCoV2 in 350 aerosol samples Traditional mould analysis compared to a DNA-based method of mould analysis Development of an environmental relative moldiness index for US homes Method of Identifying and Quantifying Specific Fungi and Bacteria ACE2 and TMPRSS2 are expressed on the human ocular surface, suggesting 363 susceptibility to SARS-CoV-2 infection Catching and killing of airborne SARS-CoV-2 to control spread of COVID-19 by a 365 heated air disinfection system Review of infective dose, routes of transmission and 367 outcome of COVID-19 caused by the SARS-COV-2: comparison with other respiratory viruses