key: cord-1017117-887eyqc2 authors: Wehrhahn, Michael C.; Brown, Suzanne; Newcombe, James P.; Chong, Smathi; Evans, Jenny; Figtree, Melanie; Hainke, Laurence; Hueston, Linda; Khan, Sadid; Marland, Elizabeth; O’Sullivan, Matthew V.N.; Powell, Helen; Roy, Jhumur; Waring, Lynette; Yu, Megan; Robson, Jennifer title: An evaluation of 4 commercial assays for the detection of SARS-CoV-2 antibodies in a predominantly mildly symptomatic low prevalence Australian population date: 2021-03-17 journal: J Clin Virol DOI: 10.1016/j.jcv.2021.104797 sha: c2cafba0fc41fe38927591162914d2c21188a9bd doc_id: 1017117 cord_uid: 887eyqc2 A total of 1080 individual patient samples (158 positive serology samples from confirmed, predominantly mildly symptomatic COVID-19 patients and 922 serology negative including 496 collected pre-COVID) from four states in Australia were analysed on four commercial SARS-CoV-2 serological assays targeting antibodies to different antigens (Roche Elecsys and Abbott Architect: nucleocapsid; Diasorin Liaison and Euroimmun: spike). A subset was compared to immunofluorescent antibody (IFA) and micro-neutralisation. Sensitivity and specificity of the Roche (n = 1033), Abbott (n = 806), Diasorin (n = 1034) and Euroimmun (n = 175) were 93.7%/99.5%, 90.2%/99.4%, 88.6%/98.6% and 91.3%/98.8%, respectively. ROC analysis with specificity held at 99% increased the sensitivity for the Roche and Abbott assays from 93.7% to 98.7% (cut-off 0.21) and 90.2% to 94.0% (cut-off 0.91), respectively. Overall seropositivity of samples increased from a maximum of 23% for samples 0-7days-post-onset of symptoms (dpos), to 61% from samples 8-14dpos and 93% from those >14dpos. IFA and microneutralisation values correlated best with assays targeting antibodies to spike protein with values >80 AU/mL on the Diasorin assay associated with neutralising antibody. Detectable antibody was present in 22/23 (96%), 20/23 (87%), 15/23 (65%) and 9/22 (41%) patients with samples >180dpos on the Roche, Diasorin, Abbott and microneutralisation assays respectively. Given the low prevalence in this community, two-step algorithms on initial positive results saw an increase in the positive predictive value (PPV) of positive samples (39%-65% to ≥98%) for all combinations. Similarly accuracy increased from a range of 98.5%-99.4% to ≥99.8% assuming a 1% seroprevalence. Negative predictive value (NPV) was high (≥99.8%) regardless of which assay was used initially.  In females, age was found to be significantly positively associated with all assay values. In males, hospitalisation showed positive associations with spike assay values  Illness severity score incorporating weighted symptoms and hospitalisation features was not associated with assay values (1, 2) . This in turn improves estimates of attack rate, case fatality rate and reproduction number (R0) in a population (3) (4) (5) . Serology may also have prognostic value, with antibody titres found to correlate with severity of infection (4, (6) (7) (8) (9) , and can assist public health investigations of outbreaks (5). In the longer term, studies may be able to assess whether herd immunity against SARS-CoV-2 has been achieved (3). If high-throughput commercial Enzyme Linked immunosorbent Assays (ELISA) or Chemiluminescent Microparticle immunoassays (CMIA/CLIA) correlate with neutralising antibody (Nab) titres, an immune population may be determined who are lower risk for returning to frontline work (3, 5) . At present, serological correlates of immunity post-vaccination are yet to be determined and published studies of Nab following infection with SARS-CoV-2 remain limited (6, (10) (11) (12) (13) (14) . Commercial assays generally target one of two proteins -the spike or the nucleocapsid protein with uncertainty about which targets are the most sensitive or correlate best with Nab (15, 16) . While published studies to date have compared commercial assays head-to-head (17) (18) (19) (20) (21) most have been in higher prevalence areas. Australia and New Zealand have been fortunate in largely eliminating transmission in the community but this has presented a unique diagnostic challenge to understand the relative performance of commercial test platforms for use in a very low incidence community. We sought to investigate the reliability of four commercial assays for use within our laboratory network in Australia. Commercial assay testing (Roche Elecsys Anti-SARS-CoV-2 assay targeting IgM/IgA/IgG to nucleocapsid protein, Abbott Architect SARS-CoV-2 IgG targeting nucleocapsid protein, Diasorin Liaison SARS-CoV-2 S1/S2 IgG targeting the S1 and S2 domains of the spike protein, Euroimmun Anti-SARS CoV-2 IgG targeting the S1 domain of the spike protein) was performed at 4 laboratories across 4 states of Australia according to the J o u r n a l P r e -p r o o f assays' instructions for use (IFU). Due to limited availability of the Euroimmun assay and residual stored sera, samples from COVID-19 patients were prioritised over specificity samples for testing using this assay. The Institute of Clinical Pathology and Medical Research, NSW performed an in-house Immunofluorescent antibody (IFA) assay (22) and a microneutralisation assay (23) as previously described. All data was de-identified and verbal consent of COVID-19 patients was obtained and approval for this study obtained from the Sullivan Nicolaides Pathology Low Risk Ethics Committee. Sensitivity analysis was performed on stored sera from confirmed patients with COVID-19 diagnosed by NAAT as defined by local guidelines and also household contacts seropositive for IgG by IFA in the absence of NAAT being performed (24, 25) . The majority of cases were diagnosed by the Seegene Allplex 2019-nCoV Assay (targeting E, N and RdRP genes) or an in-house developed Taqman assay targeting the E and N genes. Only the latest sample for each patient was selected. Seropositive samples from confirmed COVID-19 cases had to be positive by at least IFA if tested or in the absence of IFA, at least one commercial assay. A two-step algorithm analysing the different possible combinations of commercial assays to optimise positive predictive value (PPV) was evaluated (26) . The COVID-19 cases and three cohorts used to assess the specificity of the assays under evaluation are depicted in Table 1 . A novel illness severity score (ISS) assessing 19 symptoms and need for hospitalisation, intensive care support and mechanical ventilation (HIM) was developed and evaluated on a subset of patients as depicted in Table 2 . Duration of symptoms (DS) was also assessed and capped at 30 days. Receiver operator characteristic (ROC) curve analysis was undertaken to determine the area under the curve (AUC), and sensitivity, specificity and accuracy, along with 95% confidence intervals (CI), were calculated. Assay cut-off values were optimised by interrogation of ROC results. Pairwise comparisons of sensitivity and specificity between assays were made. As many of the same samples were assessed by each assay, the diagnostic measures were correlated with each other, and to account for this a procedure using 2000 bootstrap replicates was adopted (27) . Sensitivity was tested while holding specificity at 99%, then specificity was tested while holding sensitivity at 95%. A significance threshold of 0.05 was used, with a Bonferroni correction for multiple testing giving an adjusted threshold for 6 tests of α' = 0.0083. We evaluated the relationship between IFA and assay values using linear regression analysis, with adjustment for the covariates age and sex. As the IFA distribution was skewed, a normalising square root transformation was applied before subsequent analysis. Associations between the outcomes IFA, NA and SA and the predictors ISS, DS and HIM were similarly explored, with adjustment for the covariates age, sex and age by sex interaction. To correct for the effect of multiple testing on Type I error in this setting, the significance threshold was set at α' = 0.05/9 = 0.0056. The same associations were also examined in sex-stratified analyses. Data were analysed in the R statistical computing environment, version 4.0.0, including the package pROC (27) . There were 173 patients with confirmed COVID-19 by NAAT (n=169) or IFA (n=4) who had serology samples evaluated. Of these, 90(52%) were male and the mean age of patients was 50.7years (range 7-85years). Severity of disease data for 163 patients indicated that 5(3%) were asymptomatic, 131(80%) were symptomatic but nonhospitalised, 18(11%) were hospitalised/non-ICU patients and 9(6%) were ICU patients. Thirty day mortality was 0%. Of the 173 individual samples from confirmed cases and 907 negative samples, there were 158/1080(14.6%) seropositive patients. Time since illness onset available for 147 patients found 139/147(95%) were collected ≥10days-post-symptom onset (dpos). Sensitivity, specificity and accuracy results are presented in Table 3 . In the subset of 175 samples common to all assays, there were no differences in AUC among the 4 assays (all p>0.042), nor in specificity when sensitivity was held at 95% (all p>0.15). When specificity was held at 99%, there was a significant difference in sensitivity only between the Roche and Diasorin assays (p=0.003). When assay cutoff values for the Roche and Abbott assays were optimised (1.0 to 0.21 and 1.4 to 0.91, respectively) to achieve 99% specificity, sensitivity increased for both assays (Table 4 ). Twenty-nine samples from 22/158(14%) COVID-19 patients were found to be discrepant on ≥1 commercial assays (Table 5) . For a family of three COVID-19 cases, one had a positive result only on SA (16-32dpos), one only on NA (12dpos) and one with positive results from at least one of SA and NA (17dpos). Falsely negative results were found in 9/29(31%), 14/29(48%), 14/29(48%), and 17/29(59%) Euroimmun, Roche, Abbott and Diasorin results respectively. Two patients were only positive by IFA but negative/equivocal on commercial assays (although values for these two patients were above the mean negative value of pre-COVID samples). Sensitivities by time period are presented in Table 6 . Seroconversion occurred by at least 12dpos on commercial assays (range 5-12dpos). Samples remained positive beyond 180 days in the majority of patients by the Roche (96%), Diasorin (87%) and Abbott assays (65%) (Figure 1 ). The mean cutoff value from the 3 specificity cohorts ranged between 0.08-0.09, 0.06- Fourteen patients (52%) had detectable Nab (6/6 samples collected <180dpos, 9/22 (41%) samples ≥180dpos.). Significantly higher titres were found in those who were hospitalised, while samples collected ≥180dpos had lower titres (p<0.003). A minority of patients (1/14, by Roche; 2/14 by Diasorin and 3/14 by Abbott) were negative by all commercial assays but had detectable Nab. Increasing assay values only on the SA correlated with presence of Nab. All 8 patients with an assay value>80AU/mL by Diasorin were found to have detectable Nab with higher values in males than females ( Figure 2 ). Eighteen possible two-step algorithms (including optimised sensitivities for the Roche and Abbott assays) were analysed assuming a population prevalence of 1% based on recent data indicating low seroprevalence in our community (28) . PPV after the second assay improved from a range of 0.39-0.65 to ≥0.98 for all combinations. The highest PPV was obtained from the combination of the Roche and Abbott assays (0.996). Accuracy increased from a range of 0.985-0.994 to ≥0.998. The most accurate combination was the optimised Roche assay followed by the Euroimmun assay (0.999). Calculations for the Roche followed by Diasorin combination are illustrated in Figure 3 . providing 54 samples collected within 4dpos of each other, with range of collection : 7-219dpos, were matched with 18 pairs of unrelated patients (URP). No significant difference was found between the HHC and URP within-pair assay differences for IFA or the 4 commercial assays, even when this was limited to the subset of patients with probable same exposure (Table 7) . This evaluation found satisfactory performance and comparability of the tested commercial assays. Using all available samples, specificity was >98.5% (range 98.6-99.5%), and sensitivity/accuracy was high (range 88.6-93.7%/ 94.9-98.6% respectively). Sensitivity/specificity varied by 0.2-1.1%/0.5-1.8% respectively when analysis was confined to samples that were measured by all 4 assays. The area under the curve (AUC) was >97% for all assays, indicating high discriminatory power. When Discordant results by commercial assays were found in a minority (14%) of our patients as has been found in other studies (12, 17) and may relate to assay design or immune response. Also of note was the difference in persisting seropositivity between the Abbott and Roche assays on samples ≥180dpso despite targeting the same nucleocapsid protein in keeping with the indirect 'sandwich assay' design of the Roche assay that preferentially detects more mature antibody. This finding supports the use of more than one assay with differing target antigens or design as has been recommended locally and by others (8, 29) to allow serological testing to address a variety of clinical and public health questions. This is also the only currently available study providing large numbers in the Oceania region where COVID-19 case numbers are relatively limited. Reassuringly, the high specificities of the assays found in this study corresponded closely to those reported by the manufacturers (≤0.5% difference). We found that initial false positive results can be further reduced by adopting a two-step approach utilising a second assay as found by others (21, 30) . Only NA (Roche and Abbott) gained sensitivity by lowering of the positive cutoff without a significant reduction in specificity. A two-step algorithm may also increase the detection of low level antibody only detectable by one type of assay. In one of our laboratories, the use of the Roche assay as the initial screening assay has been enhanced by reflexing any results >0.2COI to the Diasorin assay. In the other laboratory in our network performing serology, positive results on the Diasorin were J o u r n a l P r e -p r o o f reflex tested on the Abbott assay. While these two combinations were not the most accurate or provided the highest PPV, they resulted in the most efficient laboratory workflow using assays targeting two different antigens and resulted in a PPV/accuracy of 98.4%/99.9% and 99.0%/99.8%respectively. In the near future, with the advent of vaccines that largely target the spike protein, there may be a need to differentiate the development of antibodies and immunity following infection (NA +SA positive) or vaccination (SA positive only) providing further reason for utilising assays that target both antigens. However, careful evaluation of the performance of available assays is required to maximise PPV as was found by Ripperger et al where their in-house nucleocapsid-specific assay was not suitably discriminatory for use in their two-step algorithm (30) . This is also one of only a few studies that have correlated commercial assay results with Nab and the only one we are aware of comparing it with reference laboratory IFA results (11) . Overall concordance of negative and positive samples with IFA was high (92-97%) and the high sensitivity of IFA in samples ≥28dpos (96%) was comparable to that reported recently by members of our group (91% for samples ≥14dpos) (22) . Nab, currently considered the best potential correlate with protective immunity, was still detectable in 9/22 (41%) of those with samples collected more than 6 months postillness. Nab also corresponded to IFA results and SA values. Taking into account the higher proportion (67%) of late collected samples (≥180dpos) of predominantly mildly infected patients in our study, we also found a similar proportion of samples with Diasorin values >80AU/mL associated with Nab titres of ≥1:160 (5/9, 56% vs 87% in the Diasorin IFU). A negative commercial assay result does not exclude the possibility of detectable Nab and possible protective immunity and caution should be taken when J o u r n a l P r e -p r o o f interpreting negative results >6 months following a compatible illness due to the possibility of false negative serology particularly in young females where antibody levels were found to be lowest in both SA and IFA. There are clear differences in mortality between males and females, despite similar incidence of infection, and this may relate to a differing immune response which is reflected in lower antibody levels (31) . While our novel ISS alone did not correlate with assay values and was likely limited by the retrospective design and associated recall and reporting bias, HIM was found to be significantly associated with higher assay values in the IFA and SA in males. Similar findings were found in one large study where higher antibody levels were seen in older and sicker patients while lower levels were seen in females suggesting gender-specific immune responses towards SARS-CoV-2 (32) . In contrast to other studies that showed lower spike:nucleocapsid antibody ratios in hospitalised and deceased patients (33, 34) , our study found the higher/highest ratios in the hospitalised/intensive care patients compared with those managed in the community. This may relate to both sampling later in the illness and ultimate recovery of patients in our study, with strong spike-specific antibody responses having been shown to correlate with survival (33) . Since greater inoculum of SARS-CoV-2 has been shown in hamster models to lead to more severe disease (35) , by comparing assay values from COVID-19 patients of the same household with matched unrelated patients, we postulated that the household group were more likely to have been exposed to a similar inoculum of SARS-CoV-2 from the same source and therefore might return similar assay values. However, this was not found to be the case and may relate to probable varying inoculum despite the same J o u r n a l P r e -p r o o f source/setting in addition to differing host factors amongst household members especially those who were genetically unrelated. Limitations of this study include its restricted demography relating only to Australian patients and the small sample size of patients with long term results (≥180dpos). In conclusion, we demonstrate that currently available commercial assays perform well with the majority of samples taken more than 6 months following infection still positive with associated neutralising antibody detected in almost half. In low prevalence areas such as Australia, the use of a two-step algorithm increases the PPV of a positive result while maintaining high NPV/accuracy. Declaration of Interests all authors declare no competing interests. This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors. Occurrence and transmission potential of asymptomatic and presymptomatic SARS-CoV-2 infections: A living systematic review and metaanalysis Estimating the asymptomatic proportion of coronavirus disease 2019 (COVID-19) cases on board the Diamond Princess cruise ship The Role of Antibody Testing for SARS-CoV-2: Is There One? The important role of serology for COVID-19 control Serological assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Profile of Immunoglobulin G and IgM Antibodies Against Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Kinetics of SARS-CoV-2 specific IgM and IgG responses in COVID-19 patients Antibody Responses to SARS-CoV-2 in Patients With Novel Coronavirus Disease SARS-CoV-2 infection protects against rechallenge in rhesus macaques Virological assessment of hospitalized patients with COVID-2019 Longitudinal observation and decline of neutralizing antibody responses in the three months following SARS-CoV-2 infection in humans Krammer F, Cordon-Cardo C. 2020. Robust neutralizing antibodies to SARS-CoV-2 infection persist for months RJ. 2020. Discordant neutralizing antibody and T cell responses in asymptomatic and mild SARS-CoV-2 infection Evaluation of Nucleocapsid and Spike Protein-Based Enzyme-Linked Immunosorbent Assays for Detecting Antibodies against SARS-CoV-2 Severe Acute Respiratory Syndrome Coronavirus 2-Specific Antibody Responses in Coronavirus Disease Patients Brief clinical evaluation of six high-throughput SARS-CoV-2 IgG antibody assays Side-by-Side Comparison of Three Fully Automated SARS-CoV-2 Antibody Assays with a Focus on Specificity Monitoring antibody response following SARS-CoV-2 infection: diagnostic efficiency of 4 automated immunoassays Comparison of four new commercial serologic assays for determination of SARS-CoV-2 IgG Evaluation of Three Commercial SARS-CoV-2 Serologic Assays and their Performance in Two-Test Algorithms The Antibody Response to SARS-CoV-2 Infection Diagnostic Procedures for Viral, Rickettsial and Chlamydial Infections CDNA. 2020. Coronavirus Disease PHLN. 2020. PHLN guidance on laboratory testing for SARS-CoV-2 (the virus that causes COVID-19) Performance of various testing methodologies for detection of heteroresistant vancomycin-intermediate Staphylococcus aureus in bloodstream isolates pROC: an open-source package for R and S+ to analyze and compare ROC curves Seroprevalence of SARS-CoV-2-specific antibodies in Sydney, Australia following the first epidemic wave in 2020 Public Health Laboratory Network (PHLN) guidance on serological testing in COVID-19 Gender Differences in Patients With COVID-19: Focus on Severity and Mortality Spread of SARS-CoV-2 in the Icelandic Population Defining the features and duration of antibody responses to SARS-CoV-2 infection associated with disease severity and outcome Syrian hamsters as a small animal model for SARS-CoV-2 infection and countermeasure development The authors would like to thank the patients who consented to providing blood samples, their collectors and laboratory staff involved and to Dr Ian Chambers, Dr Miriam Paul and Dr Rodney Givney for review of the manuscript.