key: cord-1015623-ovf7wuv3 authors: Lacour, William; Adjili, Salim; Blaising, Julie; Favier, Arnaud; Monier, Karine; Mezhoud, Sarra; Ladavière, Catherine; Place, Christophe; Pécheur, Eve‐Isabelle; Charreyre, Marie‐Thérèse title: Far‐Red Fluorescent Lipid‐Polymer Probes for an Efficient Labeling of Enveloped Viruses date: 2016-04-26 journal: Adv Healthc Mater DOI: 10.1002/adhm.201600091 sha: c3ed28c18e3cee4f064a82339cec5f1dd1a35103 doc_id: 1015623 cord_uid: ovf7wuv3 Far‐red emitting fluorescent lipid probes are desirable to label enveloped viruses, for their efficient tracking by optical microscopy inside autofluorescent cells. Most used probes are rapidly released from membranes, leading to fluorescence signal decay and loss of contrast. Here, water‐soluble lipid‐polymer probes are synthesized harboring hydrophilic or hydrophobic far‐red emitting dyes, and exhibiting enhanced brightness. They efficiently label Hepatitis C Virus pseudotyped particles (HCVpp), more stably and reproducibly than commercial probes, and a strong fluorescence signal is observed with a high contrast. Labeling with such probes do not alter virion morphology, integrity, nor infectivity. Finally, it is shown by fluorescence microscopy that these probes enable efficient tracking of labeled HCVpp inside hepatocarcinoma cells used as model hepatocytes, in spite of their autofluorescence up to 700 nm. These novel fluorescent lipid‐polymer probes should therefore enable a better characterization of early stages of infection of autofluorescent cells by enveloped viruses. In the context of recent severe outbreaks of potentially lethal viral infections (e.g., Ebola fever, avian fl u, SARS), the control of globally prevalent infections caused by viruses of infl uenza, herpes, hepatitis or fi loviruses such as Ebola should be a paramount and continuous consideration. Early stages of infection include the attachment of viral particles to host cell membranes, followed by virion internalization in intracellular compartments and release of the viral genome inside the cell. These stages are still badly characterized for several enveloped viruses. Until recently, most observations of virions were performed by transmission electron microscopy (TEM) and more rarely by atomic force microscopy (AFM). [ 1 ] TEM provides exceptional resolution but requires tedious preparation steps. Samples must be fi xed prior to observation, hampering any observation of viruses infecting live cells. AFM does not require a heavy preparation but does not enable to follow virions inside cells. However, the tracking of viral particles at various stages of their interactions with host cells is crucial to understand the infection mechanisms and undertake relevant antiviral therapies. Herein, our fi rst objective is to achieve a robust fl uorescent labeling of enveloped virions. The chosen model is the hepatitis C virus (HCV, ≈100 nm diameter), for which only few fl uorescent probes have been used to label its lipid envelope. Randall's group developed a strategy based on the use of a small lipophilic dye, DiD (1,1-dioctadecyl-3,3,3,3-tetramethyl-indodicarbocyanine). Its fl uorescence is greatly enhanced when spontaneously inserting into membranes. [ 2 ] However, due to its small size, it is susceptible of release from the viral envelope with time, thereby leading to fl uorescence signal dilution. Recently, Pécheur's group, developing strategies using octadecyl-Rhodamine B chloride (R 18 ), strengthened the observation that HCV enters hepatocytes by clathrin-dependent endocytosis and unraveled the mechanisms of action of two antiviral molecules. [ 3, 4 ] However, the fl uorescence signal of this molecular lipid probe is again rapidly diluted intracellularly, preventing the long-term tracking of labeled viral particles. We previously designed various kinds of biomoleculeend-functionalized polymer chains (e.g., with biotin, saccharide, phospholipid), [5] [6] [7] including lipid-ended polymers able to interact with the lipid bilayer of artifi cial systems such as LipoParticles [ 8 ] and liposomes. [ 9 ] In the former case, a lipidended homopolymer provided steric stabilization to LipoParticles at high salt concentration; in the latter case, a fl uorescent lipid-ended copolymer coud label liposomes of various sizes, giant (GUV), large (LUV), and small unilamellar vesicles (SUV), with diameters respectively around 5 µm, 100 nm, and below 100 nm. Such fl uorescent lipid-polymer conjugates therefore appear most appropriate as macromolecular lipid probes to label enveloped viruses. For an effi cient fl uorescent labeling, the probe should be bright, resistant to photobleaching, and provide a stable labeling with no (or limited) leakage from the viral membrane, to enable visualization during several minutes without loss of contrast. Additionally, insertion of the probe should alter neither the morphology, integrity, nor infectivity of the labeled virions. Our second objective is to track by fl uorescence microscopy labeled virions inside autofl uorescent host cells, a phenomenon that complicates optical observations. Hepatocytes exhibit autofl uorescence over the whole visible range, till ≈700 nm. [ 10 ] To circumvent this, we designed lipid-polymer probes emitting in the far-red range (650-750 nm) of major interest compared to the near-infrared one (NIR, 750-950 nm). Indeed, both far-red and NIR ranges enable to avoid most of the hepatocyte autofl uorescence; however, observations in the NIR range require specifi c optics and camera. Two far-red emitting fl uorophores were chosen: (i) a commercially available water-soluble dye bearing three negative charges and displaying a large extinction coeffi cient, FluoProbes®647H (called "A" thereafter); (ii) an uncharged dye synthesized in Andraud's laboratory, [ 11 ] belonging to the isophorone family and displaying a large Stokes shift of high interest for microscopy [ 12 ] (called "B" thereafter). We previously showed that although B dye is hydrophobic, its binding onto hydrophilic polymers led to water-soluble probes, provided that the fl uorophore density remained below 4 mol%. [ 9 ] Here, we report (i) the synthesis of A-based lipid-polymer probe, followed by thorough optical characterization of both Aand B-based fl uorescent lipid-polymer probes, (ii) their use for the labeling of a surrogate model of HCV, and (iii) observation of the resulting labeled virions inside their autofl uorescent host cells, hepatocytes, by optical microscopy. The far-red fl uorescent polymer probes were synthesized by covalent binding of far-red emitting fl uorophores along water-soluble and biocompatible copolymer chains based on poly( N -acryloylmorpholineco -N -acryloxysuccinimide), P(NAMco -NAS). Our aim was to bind several fl uorophores per chain to increase the brightness of the resulting probe, taking into account the solubility and the inherent self-quenching phenomenon. Polymer chains with/without a lipid end-group were labeled with either FluoProbes®647H (called "A") or an isophorone derivative (called "B"). B dye binding was carried out as previously described. [ 9 ] Much effort was devoted to achieve the optimal conditions for the synthesis and purifi cation of A-based polymer probes. The binding was performed in DMF, a solvent common to both polymer and dye (A was not soluble in chloroform). The binding reaction was monitored by SEC with a double refractometric/UV-vis detection, the bound dye appearing at a smaller elution volume (6.2 mL) than the free dye (8 mL) ( Figure 1 A) . The ratio between the two peaks enabled determination of the binding yield. The reaction was slow but could be accelerated by a supplementary equivalent of DIPEA after 3 h. No further improvement occurred after addition of a third equivalent after 1 d (Figure 1 B) . The kinetics reached a plateau with a 86% binding yield after 4 d ( Table 1 ). The difference between the binding yields of A onto lipid-or nonlipid-ended polymers (60% vs 86%, respectively), could be explained by a less favorable conformation of the chain in DMF due to the apolar character of the lipid end-group, rendering activated ester functions less accessible. Residual-activated ester functions were hydrolyzed in situ, leading to negatively charged polymer backbones (carboxylate functions at pH 7). The presence of such a large number of carboxylate groups per chain was expected to further improve water-solubility and favor an extended conformation of the polymer chain due to electrostatic repulsions. Purifi cation of A-based polymer probes was fi rst attempted by dialysis against water ( Figure S1 , Supporting Information). However, surprisingly, the free dye although perfectly water-soluble did not cross the dialysis membrane regardless of its molecular weight cutoff (2000-15 000 g mol −1 ). Finally, we could fully remove it by performing a dialysis against a 0.5 M NaCl solution ( Figure S2 , Supporting Information), followed by a dialysis against water to remove NaCl salt. Absorption and fl uorescence emission spectra of A-basedpolymer probes in water were similar to those of the free dye (Figure 1 C, bottom) with no difference for probes harboring a lipid end-group. Optical characteristics of B-based-polymer probes could also be determined in water (contrary to those of B dye) thanks to the hydrophilic polymer chain (Figure 1 C, top). A Stokes shift of 180 nm (5150 cm −1 ) was recorded, even larger than that of the free dye in CHCl 3 (135 nm, 4180 cm −1 ), mainly due to the redshift of the fl uorescence emission from chloroform to water. [ 9 ] For both kinds of polymer probes, the fl uorescence emission band was observed in the far-red region (650-750 nm). The molar extinction coeffi cient (ε) and fl uorescence quantum yield (Φ) of each polymer probe were determined from the absorption and emission spectra, respectively ( Table 2 ). In all cases, ε values were much higher for polymer probes than for free dyes. Concerning Φ, it is generally expected to decrease when the local dye concentration increases, due to self-quenching. [ 13 ] This is indeed observed here, as the dye density along the polymer chain increases. [ 7 ] However, Φ value of the bound dye still represents 66%-76% of the free dye one, refl ecting a positive infl uence of the carboxylate groups along the chain that favor an extended conformation of the polymer chain due to electrostatic repulsions, thereby limiting the occurrence of dimer formation (usually nonfl uorescent). Finally, a binding of 3 to 9 fl uorophores per chain provided in all cases water-soluble polymer probes with limited self-quenching. The brightness of the polymer probes was determined from their ε and Φ values, and was found two to fi vefold higher than that of free fl uorophores. LipoParticles emerged as promising entities for biotechnological applications, ranging from model membrane systems or biomolecule screening supports to therapeutic vectors. [ 14 ] Their versatile structure is due to the possibility of varying particle nature/ size and lipid formulation. [ 30, 31 ] Among all kinds of reported LipoParticles, those with sizes equal to or above 1 µm are the most relevant for optical observations. We therefore decided to use such LipoParticles as artifi cial lipid bilayers mimicking viral envelopes, to evaluate the anchoring properties of our fl uorescent lipid-polymer probes. Two strategies were chosen ( Figure 2 A): (1) incorporation of the probes during the preparation process of liposomes, further mixed with micrometersized polystyrene particles in specifi c conditions leading to their reorganization onto the colloidal surface; (2) "simple contact" between preformed LipoParticles and probes. For both strategies, LipoParticles appeared as individualized and localized fl uorescent dots. Comparison of bright fi eld and fl uorescence microscopy images clearly showed that almost all particles were labeled by the probe (Figure 2 B ). The use of a new fl uorescent probe to label a biological entity requires a thorough investigation of its potential cytotoxicity and resistance to photobleaching. Previous cytotoxicity studies on several B-based-polymer probes had revealed no toxicity up to 10 × 10 −6 M on human adherent (HeLa) and nonadherent (T lymphocytes) cells. [ 15 ] Moreover, B-based-poly mer probes have been evaluated with success for in vivo labeling of zebrafi sh embryos, with no signifi cant lethality nor abnormality or delayed development. [ 15 ] In addition, they appeared more resistant to photobleaching than a commercial far-red-emitting molecular probe, LysoTracker Red DND-99. [ 15 ] A-based-polymer probes exhibited no cytotoxicity on hepatocarcinoma Huh7.5 cells for concentrations up to 1 × 10 −6 M (data not shown). They also greatly resisted to photobleaching, since even under forced conditions (constant illumination at 100% light source power, whereas 25% is generally used for imaging), it was possible to record more than 40 successive images in cellulo before signifi cant photobleaching occurred ( Figure S3 , Supporting Information). Such proper-ties were therefore favorable to undertake enveloped virion labeling. Handling infectious viruses is a tedious procedure which can include production and purifi cation steps in Biosafety Level 3 laboratories, with random yields in terms of infectivity and purity of the fi nal viral samples. In order to bypass such limitations, we used a surrogate model of HCV virions, that is, pseudotyped particles (HCVpp). They are easy to produce in cell cultures, at high rates and with optimal reproducibility between batches. [ 35 ] HCVpp are assembled onto a retroviral core, harbor the viral glycoproteins E1-E2 at their surface (embedded in the lipid envelope), and are most suitable to track viral entry events. [ 3, 4 ] Adv. Healthcare Mater. 2016, 5, 2032-2044 www.advhealthmat.de www.MaterialsViews.com Determined taking into account the -COONa form in the M n calculation of the polymer chain; b) brightness (ε.Φ) of the polymer probe relative to free dye brightness; c) relative fl uorescence quantum yield (to free A dye); d) values determined in CHCl 3 since free B dye is not soluble in water; e) determined at λ Ex = 510 nm using Erythrosin-B in MeOH ( Φ = 0.09) as reference. [ 29 ] Dispersity, representative of the polymer chain size distribution; b) determined by SEC with a UV-vis detector; c) the charges along the polymer backbone arise from the dye (3 negative charges per A dye) and/or from a variable number of deprotonated -COOH groups depending on the pH and on the distribution of these groups along the polymer chain; d) number of fl uorophores related to the total monomer units per polymer chain. HCVpp were labeled in parallel with both kinds of fl uorescent lipid-polymer probes (bearing either A or B dye). They were also labeled with the corresponding probes without lipid endgroup, in order to assess the infl uence of the lipid moiety. As an additional control, we used DiD as a commercial molecular lipid probe. The same procedure was used for the fi ve probes, and labeled HCVpp were subsequently purifi ed. [ 3 ] Handling of the lipid-polymer probes and their subsequent use for HCVpp labeling were greatly facilitated by their water-solubility. Most importantly, these aqueous solutions are stable for months when stored at 4 °C away for light; indeed a batch of probes synthesized in 2012 exhibited similar labeling and fl uorescence properties when used in 2015. TEM imaging was carried out to check at the nanometric scale the integrity and morphology of labeled HCVpp. Uranyle acetate was chosen as the negative stain; however, in spite of numerous attempts, in the case of B-based probes, the use of uranyle acetate induced morphological artifacts to the labeled particles; we therefore chose to use phosphotungstic acid as a contrast agent instead ( Figure 3 E,F; Figure S4 , Supporting Information). As shown in Figure 3 and Figure S4 , particles labeled with A-or B-based-polymer probes with or without lipid end-group, maintained a similar morphology as that of unlabeled HCVpp, with neither particle aggregation nor lysis. The DiD probe also did not alter particle integrity nor morphology. Next, we sought to answer the following questions: (i) are the polymer probes capable of labeling enveloped virions? (ii) if so, is this labeling comparable or better than that achieved with DiD? Is there a difference between (iii) labeling achieved with A-or B-based-probes? and (iv) lipid-ended or nonlipid-ended probes? First, enlarged images (×4) from bright fi eld and fl uorescence microscopy ( Figure 4 , top panels) showed micrometer-sized clusters of HCVpp (Figure 4 A,D,G) . These clusters appeared strongly fl uorescent with a very high contrast, indicating that HCVpp labeling with both kinds of lipid-polymer probes was at least as bright as that with DiD (Figure 4 E,H compared to B) . The corresponding wide fi eld images showed many fl uorescent small spots in the case of DiD labeling (Figure 4 C) . In contrast, such fl uorescent small spots were not observed in the case of labeling with each lipid-polymer probe (Figure 4 F,I) , indicating a more stable labeling of HCVpp with lipid-polymer probes than with DiD. Additionally, we performed indirect immunofl uorescence to label the retroviral nucleocapsid of HCVpp, to ascertain the specifi city of our lipid labeling for entire virions and not for empty viral particles or membrane debris. It revealed that the signal of HCVpp Gag retroviral core [ 35 ] colocalized with the lipid-polymer probe signal (Figure 4 , bottom panels), confi rming that the fl uorescent clusters corresponded to entire virions. Finally, labeling with lipid-ended or nonlipid-ended polymer probes was compared ( Figure 5 ). When nonlipid-ended polymer probes were used, HCVpp clusters were not fl uorescent ( Figure 5 D,H) , conversely to those labeled with lipid-ended probes (Figure 5 B,F) . This was reproducible and comparable for A-and B-based polymer probes, strongly underlining that the presence of the lipid end-group in the polymer probe architecture is crucial for an effi cient labeling of enveloped virions. After virion labeling with a probe, subsequent infectivity must be assessed ( Figure 6 A) . As reported, [ 35 ] HCVpp infectivity was enhanced after their 100-fold concentration from cell supernatant (compare second with third bars). Importantly, probe-labeled concentrated HCVpp only displayed a 15 to 20% loss of infectivity after purifi cation, as compared with unlabeled concentrated HCVpp. Theferore, polymer probe incorporation per se only marginally alters HCVpp infectivity. A comparable result was obtained with DiD-labeled HCVpp, in line with our previous results [ 4 ] with R 18 . Noteworthy, infectivity of HCVpp that had been in contact with nonlipid-ended polymer probes was comparable Adv. Healthcare Mater. 2016, 5, 2032-2044 www.advhealthmat.de www.MaterialsViews.com to that of unlabeled HCVpp, confi rming the safety of our probes. We next examined whether the fl uorescence emission of the polymer probes in the far-red range was favorable to the observation of labeled HCVpp inside hepatocytes, commonly known to be autofl uorescent (due to the presence of porphyrins [ 16 ] and copper-metallothionein complexes [ 17 ] in their intracellular compartments). Since hepatocarcinoma cells were reported to display a bright red-orange autofl uorescence, [ 18 ] we fi rst investigated the fl uorescence properties of human hepatocarcinoma Huh7.5 cells over the UV, visible and far-red wavelength range. They exhibited a strong autofl uorescence in all ranges, except in the far-red where autofl uorescence was very low ( Figure S5 , Supporting Information). Importantly, it was not dependent upon the use of a fi xative agent. This observation strengthened our assumption that the use of far-red fl uorescent probes would enable effi cient tracking of virions inside cells displaying autofl uorescence. We infected Huh7.5 cells with HCVpp labeled or not with L-20K3H-A (Figure 6 comparable to previous observations with DiD or R 18 probes. [ 2, 4 ] After a 30 min-contact (panel h), these highly fl uorescent dots had migrated further inside the cells, closer to the nucleus (panel i), in agreement with previous reports on HCV intracellular traffi cking. [ 3, 4 ] To ascertain that the highly fl uorescent spherical dots observed intracellularly corresponded to clusters of labeled HCVpp, we performed colocalization experiments after Gag immuno-staining. For these experiments, cells were also stained for clathrin, a main protein actor of HCV internalization through endocytosis. [ 4, 19 ] Cells were successively imaged at 488 nm (green, to reveal clathrin), 594 nm (red, to reveal HCVpp Gag), and 635 nm (false blue color, to reveal L-20K3H-A polymer probe labeling of HCVpp envelope). Gag fl uorescence signal perfectly colocalized with that of L-20K3H-A probe ( Figure 7 , merge = magenta dots), once again confi rming the labeling of viral particles by the polymer probe. This fl uorescence signal was distributed throughout the cell after 10 min contact at 37 °C (Figure 7 A) and gathered at the periphery of the nucleus after 30 min (Figure 7 B ), in line with data shown above (Figure 6 B) . Interestingly, L-20K3H-A-labeled HCVpp were detected in clathrin-coated vesicles resulting in white dots (Figure 7 B, asterisks in zoom). This indicates that L-20K3H-A-labeled HCVpp are internalized by hepatocytes through clathrin-dependent endocytosis, in complete agreement with literature on HCV cell entry, and thereby confi rming at the cellular level that labeling of viral particles by the lipidpolymer probes does not alter their biological properties. The life cycles of several viruses of medical importance are still poorly understood; this considerably hampers our possibilities to defi ne appropriate therapeutic targets and design effi cient antivirals. Unraveling the ways they infect their host cells at the molecular level is therefore of paramount importance, especially entry pathways. Our aim was to design novel fl uorescent lipid probes capable of robust labeling of enveloped viruses to track them in autofl uorescent cells by optical microscopy. For this purpose, probes based on a biocompatible polymer backbone presenting a phospholipid moiety at one chain-end and multiple fl uorophores along the chain were synthesized ( Figure 8 ). Two kinds of dyes were used: a commercial one displaying a high extinction coeffi cient, FluoProbes®647H, and an isophorone derivative displaying a large Stokes shift. [ 11 ] The resulting polymer probes exhibited similar absorption and emission spectra as the free dye, with a fl uorescence emission in the far-red range (Figure 1 ). An optimized binding of the dyes provided water-soluble polymer probes with a two-to fi vefold brightness increase in comparison with the corresponding free dyes (Tables 1 and 2 ). Such lipid-polymer probes successfully labeled artifi cial lipid bilayers (Figure 2 ) . HCV was chosen as a model enveloped virus, since early steps of its entry into hepatocytes have been described, [ 20 ] thereby facilitating establishment of a proof-of-concept using our new probes to label virions. Yet, several stages of its interactions with host cells remain ill-defi ned, and most importantly, hepatocytes are autofl uorescent cells, which precludes the use of probes emitting in the visible range for observations by optical microscopy. [16] [17] [18] Labeling of a surrogate model of HCV, HCV pseudoparticles (HCVpp), with our far-red lipidpolymer probes was more stable and reproducible than using a commercial probe (Figure 4 ) . As a direct consequence, a strong fl uorescence signal was observed with a very high contrast, enabling visualization of virions for several minutes without loss of contrast. A complementary immunofl uorescence assay confi rmed the specifi city of virion labeling, that is, observed particles consisted in fully enveloped virions containing a capsid. The only discriminating parameter was the presence of the lipid end-group in the polymer probe architecture Adv. Healthcare Mater. 2016, 5, 2032-2044 www.advhealthmat.de www.MaterialsViews.com www.advhealthmat.de www.MaterialsViews.com ( Figure 5 ). In addition, labeling with the polymer probes did not alter the morphology nor the integrity of pseudotyped virions (Figure 3 ) , and minimally affected their infectivity (Figure 6 A) . This strongly contrasts with the 200-fold loss of infectivity of HCV labeled with DiD, as observed by Randall and co-workers. [ 2 ] We confi rmed that our labeling strategy did not alter the biological properties of virions, since they appeared to be internalized by clathrin-dependent endocytosis, as previously reported (Figure 7 ) . [2] [3] [4] Recent labeling strategies were based upon the coupling of quantum dots (QD) to the chemically modifi ed surface of virions. [ 21, 22 ] Although QD are highly bright and although virions were shown to retain their infectivity, the cytotoxicity of QD per se was not evaluated, while they appear to be cytotoxic . Cells were immuno-stained for Gag (HCVpp retroviral core protein, red) and for clathrin (as a marker of endocytosis, green). L-20K3H-A fl uorescence is presented as a false blue color. Inset: zoom of selected cellular area; asterisks denote HCVpp fl uorescence signals merging with clathrin (red + blue + green). www.advhealthmat.de www.MaterialsViews.com especially to hepatocytic cells. [ 23 ] Moreover, the overall size of QD conjugates (15-20 nm diameter) and the modifi cation of viral surface might hamper the biological properties of labeled virions. Another strategy based upon the metabolic labeling of enveloped virions by azido sugars during infection was successfully developed. [ 24 ] However, it modifi es the glycosylation profi le of envelope glycoproteins, with the risk of altering their functional properties. By comparison, our small size biocompatible polymer probes (<10 nm) appear as safe means to label virions. Using our far-red fl uorescent lipid-polymer probes, we could achieve an effi cient tracking of virions inside hepatocytic cells, with no optical contamination due to their autofl uorescence up to 700 nm (Figure 6 B and Figure 7 ) . Several cell types are autofl uorescent, which could lead to false-positive staining and erroneous conclusions. [ 25 ] It appears that our novel far-red fl uorescent lipid-polymer conjugates are most adequate probes to label enveloped viruses such as HCV (our study), and especially to perform intracellular tracking of labeled virions by optical microscopy at early stages of infection of autofl uorescent cells. This proof-of-concept opens the way to the fl uorescent labeling of other enveloped viruses, for example, infl uenza viruses, human herpes viruses, coronaviruses or fi loviruses such as Ebola, which should lead to a better understanding of the infection mechanisms of these major human pathogens, in order to undertake relevant antiviral therapies. Materials : All chemicals were purchased from Sigma-Aldrich, Acros and Fluka at the highest purity available and used without further purifi cation. Solvents were used as received from Fisher Scientifi c. Lipid dipalmitoylphosphoethanolamine (DPPE) was purchased from Avanti Polar Lipids. The FluoProbes®647H-amine dye ("A") was purchased from Interchim. The isophorone derivative dye ("B") has already been described. [ 11 ] Lipid-P(NAMco -NAS) and P(NAMco -NAS) copolymer chains have been previously synthesized, respectively from a lipid RAFT agent [ 9 ] and a tert -butyl dithiobenzoate RAFT agent. [ 26 ] All solvents used for the determination of photophysical properties were of spectrophotometric grade. Rabbit polyclonal antibody to human clathrin was from Abcam. The mouse monoclonal antibody to Gag retroviral core of HCVpp has been described elsewhere. [ 27 ] Dylight 488 and Dylight 594 secondary antibodies were from Pierce; their specifi cities for rabbit and mouse antibodies, respectively, were confi rmed in each staining experiment. Synthesis of the Polymer Probes : The synthesis of A-based-polymer probes was performed as follows: 20 mg (0.98 mmol of polymer chains corresponding to 52.2 mmol of NAS units) of P(NAMco -NAS) copolymer (with or without a lipid end-group) were dissolved in 0.25 mL of dimethylformamide (DMF) in a 2 mL eppendorf tube. Dye A (5 mg, 5.4 mmol), dissolved in a 10/90:Vol/Vol water/DMF mixture) was added together with 2 molar equivalents of di-isopropylethylamine (DIPEA). Polymer concentration was adjusted to 20 mg mL −1 with DMF. The reaction was carried out at 40 °C in the dark under stirring for several hours. The binding yield was followed by size exclusion chromatography (SEC). Hydrolysis of the residual activated ester units was carried out using 10 mL of borate buffer (50 × 10 −3 M , pH = 9) directly added to the polymer solution at room temperature under stirring for 48 h. Then, conjugates were purifi ed by dialysis (Spectrum Labs, Spectra/Por 7, MWCO: 15000 g mol −1 ), fi rst against a 0.5 M NaCl solution (2 baths), then deionized water (4 baths), and milliQ water (2 baths). The cyan-blue-colored A-based-polymer conjugates were dried by lyophilization. The synthesis of B-based-polymer probes was carried out as published. [ 9 ] Characterization Techniques : Size exclusion chromatography (SEC) with a UV-visible detector was used to monitor the binding yield of the fl uorophore onto the P(NAMco -NAS) copolymers following a previously described method. [ 28 ] This was performed using a Waters 1515 isocratic HPLC pump (fl ow rate: 1 mL min −1 ) and a Styragel HR4E Waters column (7.8 × 300 mm 2 ). The eluent was dimethylformamide (DMF) with LiBr (0.05 mol L −1 ) at 30 °C. Detection was provided by both a Waters 2410 refractive index detector and a Waters 2489 UV-visible detector set at 488 nm (B dye) or 650 nm (A dye). Analyses were performed by injection of 10 µL of the reaction medium (diluted with DMF to 5 mg mL −1 ). Data acquisition and treatment was performed using the Breeze software. UV-visible absorption spectra were recorded on a Jasco V-670 spectrophotometer at ambient temperature using 1 cm quartz cells. Fluorescence emission spectra were recorded on a Horiba-Jobin Yvon Fluorolog-3 spectrofl uorimeter at 298K, using 1 cm quartz cells. The steady-state luminescence of diluted solutions was excited by unpolarized light from a 450 W xenon CW lamp and detected at right angle (90°) by a red-sensitive Hamamatsu R928 photomultiplier tube. Spectra were reference-corrected for both the excitation source light intensity variation (lamp and grating) and the emission spectral response (detector and grating). For A-based-polymer probes, reference was A dye itself at 600 nm excitation. For B-based-polymer probes, reference was Erythrosin-B in MeOH ( Φ = 0.09) at 510 nm excitation. [ 29 ] Excitation of reference and sample was performed at the same wavelength. Labeling of Artifi cial Lipid Bilayers (LipoParticles) with the Fluorescent Polymer Probes : The procedure to synthesize LipoParticles has been previously described. [ 30 ] Briefl y, LipoParticles were prepared by adding preformed liposome dispersion to polystyrene particles. The mixture was vortexed for 1h at 70 °C and 1300 rpm. Thereafter, in order to separate the LipoParticles from nonadsorbed lipids, the dispersion was centrifuged at 9000×g for 10 min at 21 °C. The pellet containing LipoParticles was redispersed in pure water. Preformed liposomes were prepared via a "hydration of a thin lipid fi lm" process, the so-called Bangham method. Homogenization of size was performed by well-known sonication [ 30 ] or extrusion treatments. [ 31 ] For "Strategy 1," the lipid molar formulation used was 89/10/1 of 1,2-dipalmitoylsn -glycero-3-phosphocholine/1,2-dipalmitoylsn -glycero-3-phosphate/fl uorescent lipid-polymer probe (DPPC/DPPA/L-20K4H-B). For "Strategy 2," the LipoParticles (prepared with 100% DPPC) were mixed with a solution of L-20K4H-B probe in water for 1 h at 37 °C under stirring. Then, the LipoParticle dispersion was centrifuged at 9000× g for 10 min at 21 °C. Note that the initial L-20K4H-B fl uorescent polymer probe amounts were identical in both strategies. Observation of the Labeled LipoParticles by Bright Field and Fluorescence Microscopy : Observations of the labeled LipoParticles were performed on a wide fi eld microscope Leica DMI6000B using an excitation source Leica Halogen Bulb and an EMCCD camera (Hamamatsu C9100, 512 × 512 pixels, pixel size: 16 µm). A 100× oil immersion objective lens (HCX PL APO Leica, NA = 1.46) was used for both bright fi eld/ fl uorescence and a BGR fi lter (450/90; 502/15; 590/20) for fl uorescence. On the glass coverslip (170 µm), 10 µL of sample and 2µL of a 5 M NaCl solution were mixed, to decrease the Debye length and favor adhesion of the charged LipoParticles. Images were acquired with LASAF software (Leica, microscope) and Wasabi software (Hamamatsu, camera) and processed with ImageJ freeware. Cell Culture and Production of HCV Pseudoparticles (HCVpp) : Human hepatocarcinoma cells Huh7.5 [ 32, 33 ] were maintained in DMEM containing 4.5 g L −1 D-glucose and 4 × 10 −3 M L-glutamine (Invitrogen, Cergy-Pontoise, France), supplemented with 100 U mL −1 penicillin, 100 µg mL −1 streptomycin and 10% fetal calf serum (FCS, Lonza). HCV pseudoparticles (HCVpp) were obtained by the transient transfection of 293T cells by the calcium phosphate method. HCVpp of genotype 1a (H77; AF011752) were produced as previously described, [ 34, 35 ] from 293T cells cotransfected with a murine leukemia virus (MLV) Gag-Pol packaging construct, a MLV-based transfer vector encoding GFP as a reporter protein, and the E1-E2 expression constructs. Supernatants containing pseudoparticles were collected 48 h post-transfection and fi ltered on 0.45 µm. Pseudoparticles were concentrated 100-fold by ultracentrifugation through a 20% sucrose cushion at 75 000× g for 2 h at 4 °C. Pellets were then resuspended in the Huh7.5 culture medium without FCS. Labeling of HCVpp with the Fluorescent Polymer Probes : Concentrated HCVpp (200 µL) were incubated with 1 × 10 −6 M polymer probe (fi nal) at 4 °C for 30 min. [ 36 ] HCVpp were then placed onto a 20% sucrose cushion, topped with 1 mL phosphate-buffered saline (PBS) and ultracentrifuged at 135 000× g for 1 h 30 min at 4 °C in a TLA-100.4 Beckman rotor. Pellets of labeled virions were resuspended in PBS and stored at 4 °C under dark. Before use for cell infection assays, these pellets were further purifi ed as described in Blaising et al. [ 4 ] Observation of the Labeled HCVpp by TEM, Bright Field and Fluorescence Microscopy : Purifi ed labeled HCVpp were observed by TEM after negative staining with uranyle acetate or phosphotungstic acid (JEOL JEM 1400 microscope at 80 kV, CIQLE facility). Optical observations were performed on a wide fi eld microscope Leica DM IRBE using an excitation source X-Cite Series 120PC Q and a CCD camera (Hamamatsu C4880, 1280 × 1024 pixels, pixel size: 6 µm). A 63× oil immersion objective lens (HCX PL APO Leica, NA = 1.32) was used for both bright fi eld/fl uorescence and a TX2 fi lter (Excitation 560/40 nm, dichroïc 595 nm, Emission 645/75 nm) for fl uorescence. Samples (10 µL) were placed onto a glass coverslip (170 µm). Images were acquired with HIPIC32 software and processed with ImageJ freeware. For some experiments, labeled HCVpp were immuno-stained for Gag retroviral core protein, directly on the glass coverslip. Observation of Labeled HCVpp after Incubation with Hepatocarcinoma Huh7.5 Cells : Huh7.5 cells were seeded in 12-well plates at 8 × 10 4 cells per well and incubated overnight at 37 °C. Purifi ed labeled HCVpp were then added and plates incubated for 1 h at 4 °C to synchronize viral entry, followed by shift to 37 °C for 10 or 30 min. After supernatant removal and washing in PBS, cells were fi xed with methanol (20 min at −20 °C). Observations were performed with a Leica DMI4000 microscope, consisting of a confocal "spinning disk" head (Yokogawa CSU22), an EMCCD camera (Photometrics Quantem 512) and controlled by the Metamorph Software (Molecular Devices). A 63× water immersion objective lens (NA = 1.2) was used. For A-basedpolymer probes, the 635 nm laser light was used for excitation and a Cy5 fi lter set for emission (725/150 nm). Images were processed with ImageJ freeware and Adobe Photoshop. For some experiments, infected fi xed cells were immuno-stained on coverslips for Gag retroviral core [ 4 ] and clathrin. Imaging was performed using a Leica Confocal Spectral TCS SP5X microscope at 488/30 nm (Dylight 488-labeled antibody), 594/30 nm (Dylight 594-labeled antibody) and 635/40 nm (L-20K3H-Alabeled HCVpp). HCVpp Infectivity Assay : Huh7.5 cells were incubated with HCVpp, labeled or not, in complete medium for 72 h at 37 °C. The infectious titers, expressed as transducing units (TU) per milliliter, were deduced from the transduction effi ciencies, determined as the percentage of cells expressing GFP, measured by FACS analysis. [ 35 ] Supporting Information is available from the Wiley Online Library or from the author. ENS de Lyon) for the isophorone derivative and for the use of their spectrophotometer and spectrofl uorimeter equipments. The authors acknowledge Nicolas Béard for preparation of labeled HCVpp for several TEM images. W.L. acknowledges an AMI grant from the French Bioimaging network, GDR 2588 MiFoVI-CNRS, and SA a Ph.D. grant from the Région Rhône-Alpes, Cluster 5 Chimie. The authors also thank ANRS for funding (CIR 2014-1 CSS4 and AO 2013-1 CSS4 to MTC and EIP, respectively). outcome. Received