key: cord-1014465-guw92aey authors: Parra Guardado, A. L.; Sweeney, C. L.; Hayes, E. K.; Trueman, B. F.; Huang, Y.; Jamieson, R. C.; Rand, J. L.; Gagnon, G. A.; Stoddart, A. K. title: Development and optimization of a new method for direct extraction of SARS-CoV-2 RNA from municipal wastewater using magnetic beads date: 2020-12-04 journal: nan DOI: 10.1101/2020.12.04.20237230 sha: a7b0eab5e1d9ea193cc2d89fb7306f2951becf39 doc_id: 1014465 cord_uid: guw92aey The use of magnetic beads in the extraction of nucleic acids from wastewater is presented as an approach to simplify extraction techniques for the detection of SARS-CoV-2 viral fragments in wastewater. In particular, this paper describes the development and optimization of a direct method for extracting SARS-CoV-2 RNA from municipal wastewater using magnetic beads. The recovery efficiency of the method using Accuplex SARS-CoV-2 Positive Reference Material (ASCV-2) was examined. Method factors assessed were sample volume, concentration of magnetic bead mix, elution temperature, and water matrix (deionized (DI) water and wastewater). The combination of optimized method parameters that resulted in the highest RNA recovery in both DI water (26.0 {+/-} 0.8%) and wastewater (11.8 {+/-} 1.4%) was a sample volume of 1.0 mL, a magnetic beads concentration of 100 L mL-1 sample, and an elution temperature of 60 {degrees}C. The performance of this optimized method was further assessed in recovery experiments using wastewater samples spiked at 1.8x106 and 1.8x104 gene copies L-1 (GU L-1) with Gamma Inactivated SARS-COV-2 (GI-SCV-2) and 1.0x106 and 1.0x104 infectious units L-1 of Human Coronavirus 229E (HCV 229E) as viral surrogates. Recoveries of 86.1 and 4.6% were achieved for wastewater samples spiked with GI-SCV-2 at low and high concentrations, respectively. In assessing the effects of wastewater pre-filtration and addition of DL-Dithiothreitol (DTT, used to inactivate RNases that may degrade RNA) on recovery efficiency of ASCV-2, the magnetic bead-based extraction protocol performed optimally with unfiltered wastewater without DTT (recovery = 17.4 {+/-} 0.4%). The method limit of detection (MLOD) for ASCV-2 recovered from pre-filtered wastewater was determined to be 4.6x104 GU L-1 (95% degree of confidence). Using this optimized magnetic bead-based extraction protocol, the presence of SARS-CoV-2 RNA was verified in wastewater collected from sewershed locations in Atlantic Canada. This emerging RNA extraction method is direct, rapid, and does not require the use of specialized equipment, thus offering advantageous application for laboratories with limited resources. As such, this method is an indispensable tool in the monitoring of wastewater for SARS-CoV-2 to potentially understand COVID-19 infection occurrence within communities and inform public health leaders. proof-of-concept study that demonstrated the applicability of wastewater surveillance for 98 COVID-19 as a tool to understand infection rates within communities (Ahmed et al., 2020a) . To 99 effectively monitor SARS-CoV-2 viral fragment occurrence in wastewater, the development of 100 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint the University of Alberta and were spiked at the National Microbiology Laboratory. The seeded 166 wastewater was shipped to Dalhousie University on ice, and the samples were analysed within 167 48 h of seeding. The wastewater was kept at 4 °C during transport and throughout the 168 preparation of spiked samples. 169 2.3 Determination of RNA extraction conditions with magnetic beads using a factorial design 170 A screening statistical design was chosen to establish optimal conditions for the RNA 171 extraction of ASCV-2 from wastewater and maximum recovery efficiency for the RT-qPCR. Thus, 172 a full-factorial design of four factors was used to assess the magnetic bead-based extraction 173 protocol in RNA extraction. All experiments were performed according to the experimental design 174 shown in Table 1 . A total of 16 experimental runs were carried out randomly to limit the occurrence 175 of potential bias. The four independent variables in this study were ASCV-2 spiked sample volume 176 (mL) (x1), concentration of magnetic beads (µL mL -1 sample) (x2), RNA elution temperature (°C) 177 (x3), and water matrix (DI water and wastewater) (x4). The dependent variable was evaluated as 178 ASCV-2 recovery efficiency (%), calculated based on the number of copies quantified for each 179 experimental run by RT-qPCR using . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint Each seeded sample was prepared by spiking ASCV-2 in either DI water or wastewater to 185 a concentration of 1x10 6 GU L -1 , as described in section 2.2 Wastewater sample collection and 186 preparation. All RNA extractions were performed with reagents provided by LuminUltra 187 Technologies Ltd (Fredericton, NB, CA). In a 15-mL centrifuge tube, 4.9 or 6.5 mL of Lysis 188 buffer was added to 1 or 2.5 mL of spiked water sample, vortexed for 30 sec, and immediately 189 incubated at 30 °C for 10 min. A volume of 3.5 mL EtOH was added to the lysed sample; the 190 tube was gently inverted several times to mix thoroughly and then spiked with binding beads at a 191 concentration of either 15 or 100 µL per mL of sample. The mixture was vortexed for 30 sec and 192 incubated again at 30 °C for 10 min. The magnetic beads were precipitated by applying a 193 magnet, and the supernatant was discarded. The magnetic beads were transferred to a 2-mL 194 microcentrifuge tube and washed three times with 1 mL of Wash I solution. A second wash step 195 using 1 mL of Wash II solution was carried out three times. For each wash, the magnetic beads 196 were vortexed for 30 sec, and the supernatant was discarded after magnet precipitation of the 197 beads. Once washed, the tubes containing the magnetic beads were placed at room temperature 198 with the caps off for approximately 1 h to evaporate residual EtOH. Then, 50 µL of elution 199 buffer (preheated to 30 or 60 °C) was added to the magnetic beads. The tube was vortexed for 30 200 sec and incubated at either 30 or 60 °C for 5 min. Finally, the magnet was applied to ensure 201 separation, and the elution buffer was collected into a sterile tube for analysis. Controls without 202 seeded ASCV-2 were prepared to identify background concentrations of the virus in wastewater. 203 A graphical representation of the RNA extraction protocol using magnetic beads is shown in 204 CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted December 4, 2020. 8. Incubate at 60 ºC for 5 min . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted December 4, 2020. of three aliquots of 100 mL for each surrogate spike condition were prepared. Moreover, a 219 negative control was added to assess the background concentration of both surrogates in the 220 wastewater. For RNA extraction, each of the aliquots for every surrogate spike condition was 221 processed in duplicate with the optimal parameters of 1 mL sample volume, 100 µL of magnetic 222 beads per mL of sample, and RNA elution temperature of 60 °C. Following extraction, RNA was 223 quantified by RT-qPCR and the recovery efficiency of each surrogate spike condition was 224 calculated. 225 2.5 Assessing matrix effects of wastewater on RNA recovery 226 The effect of the wastewater matrix in the magnetic bead-based extraction protocol was 227 studied to improve RNA recovery efficiency. Wastewater seeded with ASCV-2 was processed 228 using two different strategies: filtration pre-treatment and addition of DTT (~1 M) to the lysis 229 buffer. For the first approach, wastewater was pre-treated by filtering through a 0.45-µm pore 230 membrane to remove particulates that may saturate the magnetic beads. A sample spiked with 231 1x10 6 GU L -1 of ASCV-2 was passed through a 47-mm diameter mixed cellulose ester 232 membrane via a sterile magnetic filter funnel (Pall Corporation, Mississauga, Ontario, Canada) 233 and filtration flask. The filtrate was immediately collected into a sterile conical tube and used for 234 RNA extraction. The second strategy involved the addition of DTT (~1 M) during the lysis step 235 to inactivate RNases that may degrade RNA. DTT was added to the lysis buffer and spiked 236 wastewater (filtered and non-filtered) at a concentration of 20 mM. 237 A total of four experiments were performed in triplicate to assess the effect of wastewater 238 pre-filtration and addition of DTT on RNA recovery efficiency using the magnetic bead-based 239 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint extraction protocol. Viral RNA extraction and quantification was carried out using the optimal 240 parameters identified by the experimental design: 1 mL sample volume, 100 µL of magnetic 241 beads per mL of sample, and RNA elution temperature of 60 °C. is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint for 3 sec followed by 60 °C for 30 sec. All RT-qPCR analyses were carried out at least in 262 duplicate, and for each qPCR run, both a positive and negative control were included. 263 The method limit of detection (MLOD) of the optimized RNA extraction method was 268 calculated using ASCV-2 spiked into wastewater that was pre-filtered as described in Section 2.5 269 Assessing matrix effects of wastewater on RNA recovery. The synthetic RNA was seeded into 270 pre-filtered wastewater in a series of decreasing concentrations (1x10 3 to 1x10 6 GU L -1 ). All 271 diluted solutions were subjected to the optimized RNA extraction method and assessed by RT-272 qPCR in six replicates. Before adding ASCV-2, the wastewater sample was analyzed for the 273 presence of SARS-CoV-2 to obtain background levels. The percentage of replicates that resulted 274 in a positive detection for each dilution were compared to the spiked virus concentration, and the 275 data were fitted to a Gompertz model (Tjørve and Tjørve, 2017 ). Using this model, the dilution 276 reporting the lowest non-negative concentration at a 95% confidence level was selected as the 277 MLOD. 278 279 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint CoV-2 in wastewater 281 The application of the RNA extraction and RT-qPCR methods were evaluated in raw 282 wastewater samples from three locations in Atlantic Canada. In Fall 2020, wastewater samples 283 were collected from Communities A, B, and C over five, eight, and four sampling events, 284 respectively. RNA fragment extraction was carried out using the optimal parameters identified 285 by the experimental design: 1 mL sample volume, 100 µL of magnetic beads per mL of sample, 286 and RNA elution temperature of 60 °C. 287 288 2.9 Quality control 289 To minimize contamination, RNA extraction and RT-qPCR assays were carried out in 290 separate laboratories. A method blank was included during RNA extraction to account for any 291 contamination during sample processing. The extracted RNA was stored at -76 °C and subjected 292 to RT-qPCR within the same day of extraction. 293 294 2.10 Statistical analysis 295 All analyses were performed at least in duplicate. Results were expressed as average 296 values ± standard deviation and were submitted to analysis of variance (ANOVA) with a 95% 297 confidence level. The response variable in the full-factorial design was modeled as a linear 298 combination of the main effects and two-way interactions, and residuals were approximately 299 Gaussian and homoscedastic. For experiments assessing the effect of wastewater matrix on 300 recovery efficiency, Tukey's test for post-hoc analysis was used to evaluate group pairings that 301 were significantly different. The MLOD was assessed by plotting percent positive results against 302 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint the known spiked ASCV-2 concentrations in the series of MLOD test wastewater samples. A 303 best fit Gompertz model was fitted to the data, and the MLOD was calculated from the equation 304 generated from the best fit model when the value of percent positive (y-axis) was 95%. All 305 statistical analyses were performed using R studio software v. 3.6.2 ('easynls', 'ggplot2', 306 'tidyverse' packages) ( The effects of sample volume, concentration of magnetic beads, and elution temperature 310 on ASCV-2 RNA recovery in DI water and municipal wastewater were assessed through a 311 factorial experimental design (Table 3 ). The combination of optimized method parameters from 312 the full-factorial design that resulted in the highest RNA recovery in both DI water (26.0 ± 0.8%) 313 and wastewater (11.8 ± 1.4%) was a sample volume of 1.0 mL, a magnetic beads concentration 314 of 100 µL mL -1 sample, and an elution temperature of 60 ºC. Overall, ASCV-2 recoveries were 315 clearly influenced by the water matrix with values ranging from 1.3 to 11.8% for wastewater and 316 6.3 to 26.0% for DI water. To better visualize the influence of the factors on RNA recovery, a 317 response surface contour plot illustrating the relationship among the dependent (sample volume, 318 bead mix concentration, elution temperature, and water matrix) and independent (% recovery) 319 factors was generated (Figure 2 ). It is important to note that SARS-CoV-2 was not detected in 320 any of the unseeded wastewater samples. 321 322 323 324 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint The factorial experimental design demonstrated that a lower sample volume of 1 mL 329 resulted in consistently higher mean RNA recoveries than did a sample volume of 2.5 mL when 330 assessed at the same conditions for all other variables. The effect calculated from the linear 331 model showed that increasing the volume from 1 to 2.5 mL decreased recovery by 3.3x10 4 GU 332 L -1 . These results suggest that a larger volume may have diluted the concentration of magnetic 333 beads and decreased contact between the beads and RNA. Thus, using smaller sample volumes 334 allowed more bead-RNA collisions and subsequent binding of RNA onto the magnetic beads, 335 which was reflected in higher recovery yields (Yuan et al., 2019) . 336 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. extraction as samples consisting of 50 mL, which is 50-fold greater than the optimal volume 347 determined in this study. Working with smaller wastewater sample volumes is advantageous, as 348 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint they are easier and safer to handle, store, and transport. While this method performs optimally at 349 low sample volumes (1 mL), it does not incorporate a concentration step, indicating that it is 350 suitable for wastewater samples that contain SARS-CoV-2 in concentrations present above its 351 method detection limit. increases in recovery from wastewater and DI water, respectively) than did a concentration of 15 367 µL mL -1 sample. Furthermore, when magnetic beads were dosed at a concentration of 100 µL 368 mL -1 sample, the recovery efficiency was maximized at low sample volume and minimized at 369 higher sample volumes. The effect of this factor calculated from the linear model showed that 370 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint increasing the concentration of magnetic beads from 15 to 100 µL mL -1 sample increased 371 recovery by 5.7x10 4 GU L -1 . These results support our initial premise that a larger sample 372 volume may dilute the concentration of magnetic beads, which leads to lower RNA recoveries. formed between nucleic acids-adsorption materials, therefore, serving as an ideal tool to enhance 386 the elution process (Li et al., 2011) . However, it should be considered that high elution 387 temperatures (>60 ºC) may increase the risk of RNA denaturation. In our preliminary 388 experiments, recovery efficiency increased considerably when RNA was eluted at 55 ºC in 389 comparison to room temperature (data not shown), and it was further improved by incubating at 390 60 ºC. It is likely that the short incubation periods used in this work in combination with the pre-391 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. 2020d). In this work, the degree of inhibition was expected to be lower, as samples were not pre-412 concentrated prior to RNA extraction. Nonetheless, inhibition was assessed by comparing Ct 413 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint values obtained for wastewater samples to those obtained for DI water samples (reference value). 414 Samples having Ct values greater than two cycles above the reference point were considered to 415 be impacted by PCR inhibition (Ahmed et al., 2020b) . In these experiments, the difference 416 between the wastewater Ct value and the reference value for DI water was less than two cycles, 417 which suggests low inhibition from the wastewater matrix. These results may be attributed to . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint Table 4 . Effects of wastewater pre-filtration and DTT addition on recovery efficiency of ASCV-436 2 using the magnetic bead-based extraction protocol (n=3). 437 A . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint The optimized magnetic bead-based extraction protocol was evaluated for recovery of GI-456 SCV-2 and HCV 229E as SARS-CoV-2 surrogates in wastewater. Overall, the method allowed 457 differentiation between high and low concentrations, and non-spiked wastewater samples. 458 Neither of the two surrogates were detected in the negative samples. Mean concentrations of 459 8.33x10 4 ± 7.8x10 3 GU L -1 and 1.55x10 4 ± 3.6x10 3 GU L -1 were recovered for samples spiked at 460 high and low concentrations of GI-SCV-2. 461 In preliminary experiments, mean GI-SCV-2 recovery was 86.1% for the low spike 462 concentration, whereas at the high spike concentration, mean recovery dropped to 4.6%. A 463 potential cause for the decrease in GI-SCV-2 recovery at the high spike concentration may be 464 To investigate inhibition as a potential cause of the GI-SCV-2 recovery loss, RNA extracts 474 from the wastewater samples spiked with 1.8x10 4 and 1.8x10 6 GU L -1 were diluted 10-and 50-475 fold, respectively (n=3). For the low spike concentration, the RNA was diluted beyond the 476 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint detection limit and could not be enumerated. However, recoveries for the diluted RNA extracts 477 from the high spike concentration samples increased from 4.6 to approximately 100.1%. This 478 observation supports the hypothesis that the wastewater samples contained PCR inhibitors that 479 were co-extracted with surrogate RNA. During qPCR analysis, these inhibitors likely interfered 480 with the accurate amplification of RNA samples and substantially reduced the recovery of GI-481 SCV-2. When the extracted RNA was diluted (along with the co-extracted inhibitors) and 482 reanalyzed, the diminished interference in the qPCR reaction allowed for more accurate RNA CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint The MLOD was evaluated by spiking ASCV-2 in filtered wastewater over a concentration 498 range of 1x10 3 to 1x10 6 GU L -1 and calculated using a best fit Gompertz model (R 2 = 0.980) 499 ( Figure 3) . The method was able to detect 100% of the replicates when the virus was present at 500 high concentrations (4.0x10 4 to 1.0x10 6 GU L -1 ). However, the percentage of positive replicates 501 decreased as the ASCV-2 concentration decreased. As shown in Figure 3 , the experimentally 502 determined MLOD for the detection of ASCV-2 in wastewater with 95% confidence was 503 approximately 4.6x10 4 GU L -1 . This value is within the range of theoretical limits of detection 504 (10 3 to 10 6 GU L -1 ) reported for 36 different methods used to quantify SARS-CoV-2 in raw 505 wastewater (Pecson et al., 2020) . 506 507 508 Figure 3 . Calculation of the method limit of detection (MLOD) using a best fit Gompertz model 509 (R 2 = 0.980). 510 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint The results of wastewater analysis for Communities A, B, and C are shown in Figure 4 . A 512 total of eight samples from the WWTFs (influent) in Community A were tested, none of which 513 tested positive for SARS-CoV-2 RNA fragments. However, of the five samples analyzed from 514 the sewershed in Community A, one tested positive for SARS-CoV-2 at a concentration of 515 3.25x10 2 GU mL -1 . Although this value is below the MLOD, the detection of SARS-CoV-2 in 516 this sample may attributed to a difference in the degree of water matrix interferences. All 22 517 samples tested from the Community B WWTFs (influent/effluent) and pump station tested 518 negative for SARS-CoV-2 RNA fragments. The presence of SARS-CoV-2 RNA was verified in 519 samples collected from the Community C sewershed on Day 1 (6.6x10 4 GU L -1 ) and Day 3 520 (1.4x10 4 GU L -1 ) ( Table 5) . 521 522 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. 533 534 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint These results demonstrate that the magnetic bead-based extraction protocol allows 535 detection of SARS-CoV-2 RNA fragments when the virus is present in the wastewater sample 536 above the MLOD. However, the virus may remain undetected in samples processed using this 537 method if the viral RNA is present in concentrations below the MLOD. As observed in Table 5 , 538 the concentration of SARS-CoV-2 remained below the MLOD during the third and fourth 539 sampling events for the sewershed and for all sampling events for the WWTF Influent. Viral load 540 from faeces varies largely within wastewater depending on the time of infection onset. Peak viral 541 shedding for SARS-CoV-2 is known to occur within two to three weeks of the onset of initial 542 symptoms (Zheng et al., 2020) . The results presented in this section demonstrate the potential of 543 the rapid method proposed in this work for the detection and surveillance of SARS-CoV-2 in 544 wastewater using optimal method parameters: 1 mL sample volume, 100 µL of magnetic beads 545 per mL of sample, and RNA elution temperature of 60 °C. 546 547 This work outlines the development and optimization of a rapid and effective magnetic 549 bead-based extraction protocol in the detection of SARS-COV-2 in complex wastewater 550 samples. Through the optimization of the developed method, we found that the water matrix 551 impacted the recovery of ASCV-2 with values ranging from 1.3 to 11.8% for wastewater and 6.3 552 to 26.0% for DI water. Moreover, extracting RNA from wastewater (rather than DI water) 553 decreased RNA recovery by 7.8x10 4 GU L -1 . Additional experiments testing the effects of 554 filtration and the addition of DTT on RNA recovery showed that there was no significant 555 difference in the recovery efficiency of ASCV-2 from filtered and non-filtered wastewater nor 556 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint with the addition of DTT (20 mM) to the lysis buffer, and thus, further work may be necessary to 557 address water matrix effects. 558 Independent of the water matrix, a higher elution temperature resulted in higher RNA 559 recoveries in both DI water and wastewater, and recovery increased by 5.7x10 4 GU L -1 as elution 560 temperature increased from 30 to 60 °C. Moreover, a smaller sample volume of 1 mL resulted in 561 higher mean RNA recoveries than did a sample volume of 2.5 mL when assessed at the same 562 conditions for all other variables. In general, increasing the sample volume from 1 to 2.5 mL 563 decreased recovery by 3.3x10 4 GU L -1 . The concentration of magnetic beads in the sample also 564 greatly impacted results, as RNA recovery increased by 5.7x10 4 GU L -1 as the concentration of 565 magnetic beads increased from 15 to 100 µL mL -1 sample. 566 Using optimal method conditions, recoveries of GI-SCV-2 spiked in wastewater samples 567 at 1.8x10 4 and 1.8x10 6 GU L -1 were 86.1 and 4.6%, respectively. The method limit of detection 568 (MLOD) for this optimized method in pre-filtered wastewater was determined to be 4.6x10 4 GU 569 L -1 with a 95% degree of confidence. The detection of SARS-CoV-2 in wastewater samples 570 collected from the sewersheds of Communities A and C demonstrated that with viral RNA 571 concentrations above the MLOD, the magnetic bead-based extraction protocol allowed rapid 572 identification of SARS-CoV-2 in wastewater without the need for sample pre-concentration or 573 centrifugation. 574 The optimized method described in this work may be used as an essential tool for the 575 wastewater surveillance of SARS-CoV-2. The method protocol is simple and transferable, thus 576 offering advantageous application for laboratories or circumstances that may have limited 577 resources. 578 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint The authors declare that LuminUltra Technologies Ltd. provided equipment, some reagents and 580 technical support to assist in this work. The authors declare that they do not have any financial 581 interest in LuminUltra Technologies Ltd. 582 Coalition. The authors thank LuminUltra Technologies for providing qPCR technology and for 591 technical support that was led through Dr. Jordan Schmidt throughout the project. The authors 592 would like to extend thanks to municipal staff in communities A, B, and C for sample collection. 593 As well, the authors would like to extend thanks to researchers Paul Bjorndahl and Sebastian 594 Munoz from the Centre for Water Resources Studies at Dalhousie University for providing 595 technical reviews, data analysis, and data visualization during the study. Graphical abstract was 596 adapted from "Quantifying SARS-CoV-2 Virions in City Wastewater", by BioRender.com 597 (2020); retrieved from https://app.biorender.com/templates. 598 599 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted December 4, 2020. ; https://doi.org/10.1101/2020.12.04.20237230 doi: medRxiv preprint PCR Inhibition of a Quantitative PCR for 601 Detection of Mycobacterium avium Subspecies Paratuberculosis DNA in Feces: Diagnostic Implications 602 and Potential Solutions First confirmed detection of SARS-CoV-2 in untreated wastewater in Australia: A 606 proof of concept for the wastewater surveillance of COVID-19 in the community Decay of SARS-CoV-2 and surrogate murine hepatitis virus RNA in untreated 611 wastewater to inform application in wastewater-based epidemiology Comparison of virus concentration methods for the RT-qPCR-based recovery of 616 murine hepatitis virus, a surrogate for SARS-CoV-2 from untreated wastewater CoV-2 RNA in wastewater: Methods optimization and quality control are crucial for generating reliable 621 public health information Magnetic bead technology for viral RNA extraction from serum in blood bank 624 screening easynls: Easy Nonlinear Model RT-qPCR Testing of SARS-CoV-2: A Primer Making Waves: Coronavirus detection, 629 presence and persistence in the water environment: State of the art and knowledge needs for public health CDC, 2020. CDC 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel: CDC-006-00019 Viruses in wastewater: occurrence, abundance and detection methods Hydrophilic and 637 cationic latex particles for the specific extraction of nucleic acids SARS-CoV-2 640 from faeces to wastewater treatment: What do we know? A review Measuring and mitigating inhibition during 643 quantitative real time PCR analysis of viral nucleic acid extracts from large-volume environmental water 644 samples COVID-19 surveillance in Southeastern Virginia using wastewater-based 647 epidemiology Quantification of SARS-CoV-2 and cross-assembly phage (crAssphage) from wastewater to monitor coronavirus transmission within communities Validation of Internal Controls 653 for Extraction and Amplification of Nucleic Acids from Enteric Viruses in Water Samples Integrated DNA and RNA 656 extraction using magnetic beads from viral pathogens causing acute respiratory infections Differential 659 susceptibility of PCR reactions to inhibitors: an important and unrecognised phenomenon First proof of the capability 662 of wastewater surveillance for COVID-19 in India through detection of genetic material of SARS-CoV-2 First detection of SARS-CoV-2 in untreated wastewaters in Italy Quantitative real-time PCR of enteric viruses in 668 influent and effluent samples from wastewater treatment plants in Italy Adsorption and Desorption Behaviors of DNA with Magnetic Mesoporous Silica 671 An optimized method for elution of 673 enteroviral RNA from a cellulose-based substrate Rapid and irreversible reduction of protein disulfide bonds Efficient and scalable serial extraction of DNA and RNA from frozen 678 tissue samples Presence of SARS-Coronavirus-2 RNA in 680 Sewage and Correlation with Reported COVID-19 Prevalence in the Early Stage of the Epidemic in The 681 Sewage analysis as a tool for the COVID-19 pandemic 683 response and management: the urgent need for optimised protocols for SARS-CoV-2 detection and 684 quantification SARS-CoV-2 in Detroit Wastewater Reproducibility and sensitivity of 36 methods to quantify the SARS-CoV-2 690 genetic signal in raw wastewater: findings from an interlaboratory methods evaluation in the U Focus on: an overview of cycle threshold values and 694 their role in SARS-Cov-2 real-time PCR test interpretation. Queen's Printer for Ontario R: A language and environment for statistical computing SARS-CoV-2 RNA 697 in wastewater anticipated COVID-19 occurrence in a low prevalence area Bacterial RNA Extraction and Purification from Whole Human Blood 700 Using Isotachophoresis [WWW Document The epidemiology and pathogenesis of coronavirus disease (COVID-19) 702 outbreak PCR inhibitors -occurrence, properties and removal PCR-ready human 706 DNA extraction from urine samples using magnetic nanoparticles Optimization of influencing 709 factors of nucleic acid adsorption onto silica-coated magnetic particles: Application to viral nucleic acid 710 extraction from serum Review article: gastrointestinal features in COVID-19 and the 712 possibility of faecal transmission The use of Gompertz models in growth analyses, and new Gompertz-model 715 approach: An addition to the Unified-Richards family Quantitative Reverse Transcriptase PCR Assays for Absolute Quantitation of Human Coronaviruses OC43 719 and 229E A re-evaluation of dilution for eliminating PCR inhibition in 721 soil DNA samples World Health Organization, 2020. WHO Coronavirus Disease (COVID-19) Dashboard [WWW Document SARS-CoV-2 titers in 730 wastewater are higher than expected from clinically confirmed cases Evaluation of lockdown impact on SARS-CoV-2 dynamics through viral genome quantification in Paris 734 wastewaters Survivability, Partitioning, and Recovery of Enveloped Viruses in Untreated Municipal Wastewater Redistribution of 739 intracellular and extracellular free & adsorbed antibiotic resistance genes through a wastewater treatment 740 plant by an enhanced extracellular DNA extraction method with magnetic beads Viral load dynamics and disease 745 severity in patients infected with SARS-CoV-2 in Zhejiang province, China A Novel Coronavirus from Patients with 749 Pneumonia in China