key: cord-1014257-attgl3l1 authors: Hofmaenner, Daniel A.; Wendel Garcia, Pedro David; Duvnjak, Branko; Chakrakodi, Bhavya; Maier, Julian D.; Huber, Michael; Huder, Jon; Wolfensberger, Aline; Schreiber, Peter W.; Schuepbach, Reto A.; Zinkernagel, Annelies S.; Buehler, Philipp K.; Brugger, Silvio D. title: Bacterial but no SARS-CoV-2 contamination after terminal disinfection of tertiary care intensive care units treating COVID-19 patients date: 2021-01-12 journal: Antimicrob Resist Infect Control DOI: 10.1186/s13756-021-00885-z sha: 68fe86176ed12e70824049c040e63dcf109c8f23 doc_id: 1014257 cord_uid: attgl3l1 BACKGROUND: In intensive care units (ICUs) treating patients with Coronavirus disease 2019 (COVID-19) invasive ventilation poses a high risk for aerosol and droplet formation. Surface contamination of severe acute respiratory syndrome Coronavirus 2 (SARS-CoV-2) or bacteria can result in nosocomial transmission. METHODS: Two tertiary care COVID-19 intensive care units treating 53 patients for 870 patient days were sampled after terminal cleaning and preparation for regular use to treat non-COVID-19 patients. RESULTS: A total of 176 swabs were sampled of defined locations covering both ICUs. No SARS-CoV-2 ribonucleic acid (RNA) was detected. Gram-negative bacterial contamination was mainly linked to sinks and siphons. Skin flora was isolated from most swabbed areas and Enterococcus faecium was detected on two keyboards. CONCLUSIONS: After basic cleaning with standard disinfection measures no remaining SARS-CoV-2 RNA was detected. Bacterial contamination was low and mainly localised in sinks and siphons. During the last months, the novel Coronavirus disease pandemic has challenged many health-care systems worldwide. In line with the growing knowledge about specific pathophysiologic mechanisms, COVID-19 has increasingly been associated with bacterial coinfections, exhibiting high rates in intensive care units (ICUs) [1] [2] [3] [4] . It is estimated that around 50% of fatalities associated with COVID-19 had secondary infections contributing to the disease course with a relevant impact on patient outcomes [5, 6] . Treating critically ill COVID-19 patients often involves mechanical ventilation, which poses a high risk for droplet and aerosol transmission. In addition to the risk of severe acute respiratory syndrome Coronavirus 2 (SARS-CoV-2) contamination of surfaces and medical equipment, bacterial pathogens complicating the disease course can be transmitted to the environment surrounding the patient. Equipment and surfaces (e.g. respirators, beds) are well known for contributing to the transmission of bacterial pathogens promoting nosocomial infections [7, 8] . *Correspondence: silvio.brugger@usz.ch † Philipp K. Buehler and Silvio D. Brugger have contributed equally to this work 2 Department of Infectious Diseases and Hospital Epidemiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich, Switzerland Full list of author information is available at the end of the article With the decline of the current COVID-19 outbreak in some countries, affected ICUs now returning to treating non-COVID-19 patients are being faced with the challenge of disinfecting their equipment and facilities in order to prevent hospital-acquired infections. Moreover, it is currently not well characterised whether or how long SARS-CoV-2 ribonucleic acid (RNA) persists on surfaces after complete disinfection of ICUs. The aim of this study was to investigate the burden of pathogenic bacteria and SARS-CoV-2 RNA on different devices and surfaces after terminal cleaning measures in two specialised ICUs of a tertiary care hospital exclusively treating COVID-19 patients. This single-blinded study was conducted at the University Hospital Zurich, Switzerland, a tertiary care hospital with around 980 beds. During the COVID-19 pandemic, two defined subunits of the ICU were designated to exclusively treat COVID-19 patients. The first (ICU 1) had the capacity to treat 16 patients, the second (ICU 2) 12 patients. In total, ICU 1 treated 39 COVID-19 patients (661 patient days). ICU 2 treated 14 COVID-19 patients (209 patient days). No institutional review board (IRB) approval was required as this study did not involve any patients. After the first COVID-19 wave, both subunits were cleaned in order to provide care for non-COVID-19 patients. All surfaces, devices and floors in ICU 1 were disinfected by nurses and cleaning staff with aldehydebased Kohrsolin ® 1% (Wilbert Hygiene, Germany). In addition, a dry mist hydrogen peroxide (H 2 O 2 ) nebulisation technique (Dosymist XL, SolidFog Technologies ® , Belgium and H 2 O 2 à 12% Fisher Scientific ® , USA) was used in ICU 1 in the ICU pharmacy room. The purpose to use this relatively novel technique in the present study was to gain more experience with it and to test it in a small, designated area. With the aid of the hydrogen peroxide technology, a dry aerosol is generated, with the oxidative action of hydroxyl radicals leading to antimicrobial properties. Quality control of the H 2 O 2 disinfection was performed with chemical indicators (3M Healthcare ® , USA) [successful decontamination indicated by color change on test kit] and biological indicators (Geobacillus stearothermophilus, Crosstex ® , USA) [successful decontamination indicated by 6-log reduction between positive and negative control]. Surfaces, devices and floors in ICU 2 were disinfected by nurses and cleaning staff with Kohrsolin ® 1% (Wilbert Hygiene, Germany) only. To minimize biases, nurses and cleaning staff were not aware that this study would be conducted in both ICUs. Cleaning and disinfection were not supervised by the study team. After the cleaning procedures, 86 viral swabs (FLO-QSwabs, UTM-RT transport medium, Copan ® , Italy) were taken from different locations in both ICUs (representing high-frequency touch surfaces, patient-surrounding areas, healthcare-worker changing areas and sinks including siphons) with a minimal swabbing surface dimension of 10 × 10 cm. Sampling objects were 30 monitors/keyboards (bedside), 8 tabletops to prepare drugs for application including adjacent sinks, 17 individual sinks including siphons in patient rooms, 6 floors of patient compartments and 1 main exit gate (floor), 13 respirator touch screens and handling buttons, 2 physician's work desks, 2 non-personalised telephones, 2 perfusors, 4 rolling trolleys/tables, 2 fridge doors in the ICU pharmacy, 1 chair and 2 surfaces in kitchens. Due to the different configurations and designs of the two ICU subunits, it was not possible to take an equal amount of swabs from both ICU subunits. Figure 1 demonstrates both ICU subunits and sampling points are indicated. The swabbed area was individualised according to the swabbed object size and shape. Real-time reverse transcriptase polymerase chain reaction (rtPCR) was performed to detect SARS-CoV-2 RNA with inclusion of positive and negative control. PCR conditions were as previously described by Corman et al. [9] . In parallel to the viral sampling, a total of 90 moistured swabs (eSwabs ™ , Copan ® , Italy, comprising 1 millilitre of Amies medium) were taken from the same locations in both ICUs, analogous to the viral sampling ( Fig. 1) . Dependent on the object size and shape, the swabbed area was individualised. In general, the largest possible area to swab was chosen. All swabs were plated on 5% sheep blood agar and MacConkey agar plates in three fractions. Subsequently, the samples were incubated for 48 h at 37 °C in ambient air. After incubation, colony forming units (CFU) were analysed semiquantitatively. Growth in the first fraction of the agar plate corresponded to 10 3 -10 4 CFU/ml, in the first and second fraction to 10 4 -10 5 CFU/ml and in all three fractions to 10 5 -10 6 CFU/ml. Subcultures were plated on 5% sheep blood agar or MacConkey agar and identification was done as previously described [10] with the exception that identification was done using both a BD Phoenix ™ , Becton Dickinson, USA, automated identification and susceptibility testing system as well as a Bruker MALDI-TOF-MS biotyper (Bruker, Germany). Susceptibility testing was done using the BD Phoenix system. All of the 86 viral swabs sampled tested negative for SARS-CoV-2 RNA. Two samples from ICU 1 (sink in the pharmacy and one monitor/keyboard) were initially weakly positive but inconclusive. The quantification cycle values for those two swabs were 43.17 and 38.94 respectively. However, this finding could not be reproduced in a subsequent confirmatory test. All chemical and biological indicators demonstrated successful (bacterial) decontamination of the ICU 1 pharmacy room. Tables 1 and 2 summarise cultivated bacteria on different surfaces of both subunits of the ICU after disinfection. In ICU 1, most bacteria were found in the sinks and associated siphons-in the individual sinks in Table 1 patient rooms and at tabletops employed for drug preparation by health care staffing (Table 1) . Pseudomonas aeruginosa, Pseudomonas putida, Stenotrophomonas maltophilia, Klebsiella oxytoca and Enterobacter cloacae were cultured from these areas. In line with ICU 1, Pseudomonas aeruginosa, Pseudomonas putida, Stenotrophomonas maltophilia and Achromobacter spp. were found in ICU 2 in the sinks (Table 2) . No multidrug-resistant (MDR) P. aeruginosa was detected. Enterococcus faecium was cultivated in two out of 12 swabs from monitors/keyboards. In both ICUs, coagulase-negative Staphylococci were found in most swabbed areas but with low CFU numbers (mostly 10 3 -10 4 per ml corresponding to less than 5 CFU/cm 2 ) (Tables 1 and 2 ). The aim of this study was to investigate the persistence of SARS-CoV-2 and bacteria on different devices and surfaces after disinfecting measures in two tertiary care ICU subunits that had exclusively treated COVID-19 patients. The main finding of this study is that no SARS-CoV-2 RNA was detected by rtPCR. However, pathogenic bacteria were abounded mainly in sinks and corresponding siphons of the ICUs and enterococci were isolated from two monitors. Gram-positive bacteria were mainly isolated from surfaces (e.g. monitors/keyboards) whereas Gram-negative bacteria were mainly detected in plumbing units. To date, it has not been clearly established how long and to what extent SARS-CoV-2 RNA contaminates environmental surfaces and devices in hospitals. A recent study has described a low percentage of positive samples in an emergency room and the sub-intensive care ward [11] . In another study, almost 57% of rooms treating COVID-19 patients had at least one environmental surface contaminated [12] . In our study, viral RNA was not detectable on any of the swabbed locations of the two ICU subunits, which suggests that conventional disinfection measures are likely sufficient to prevent further spread of the virus. This finding thus might contribute to infection and prevention policies. Already back in 1974, The Lancet published an article describing isolation of Pseudomonas aeruginosa in hospital sinks [13] . Since then, various studies have investigated hospital water supply systems as potential reservoirs for the transmission of pathogenic bacteria in hospitals [14] [15] [16] [17] [18] . In line with previous studies [15, 16, 18] , we found Pseudomonas aeruginosa in sinks/siphons in both ICUs. Specifically regarding the ICU setting, Zhou et al. demonstrated that sink traps may act as an important source of Pseudomonas spp. leading to colonisation or infection of critically ill patients [18] . Additionally, stagnant water in general bears a risk for being a reservoir and source of outbreaks with several pathogens [19] . This finding highlights the need for constant awareness of possible bacterial reservoirs and the need for further refining cleaning methods in the ICU. In this line of research it has been suggested that devices applying heat and electromechanical vibration to siphons lead to lower colonisation of patients with multidrug-resistant (MDR) Pseudomonas spp. [16] and that self-disinfecting sinks reduced Pseudomonas spp. bioburden in a pediatric ICU [20] , offering possibilities to lower transmission of MDR pathogens. Whether such measures prove feasible and effective in other ICU settings remains to be elucidated in further studies and is beyond the scope of this study. However, no MDR Pseudomonas aeruginosa was detected in our ICUs despite the fact that several patients in the ICU had been colonised with MDR Pseudomonas aeruginosa. Other cultured bacteria associated with moist environments were Stenotrophomonas maltophilia, Klebsiella oxytoca and Achromobacter spp., all Gram-negative, potentially harmful bacteria. Stenotrophomonas maltophilia is known to cause hospital-acquired infections and is associated with multidrug resistance [21, 22] . Klebsiella spp. can be responsible for infectious complications, especially hospital-acquired pneumonias, urinary tract infections or septicemias [23] . Furthermore, Achromobacter spp. have been linked to increased risk of morbidity and mortality in critically ill patients in a study reporting a 18 month lasting epidemic in an ICU [24] . Additionally, Enterobacter cloacae was cultured from sinks located next to tabletops employed for drug preparation in ICU 1. Enterobacterales (especially carbapenem-resistant strains) are an important cause of healthcare-associated infections and transmission by means of environmental reservoirs, such as therapeutic beds, has been described [25, 26] . The colonisation of critically ill patients with carbapenemase-producing Enterobacterales has been associated with an increased length of stay, as well as with a 1.8 higher death hazard ratio as opposed to non-colonised ICU patients [27] . Such findings mandate thorough disinfection of ICUs and surveillance of sinks and siphons as a source for further outbreaks. Water-free ICUs might reduce the risk of nosocomial transmission from bacteria residing in sinks and siphons [28] . Monitors and keyboards are frequently used devices in the everyday care in the ICU. We found Enterococcus faecium on two out of 12 monitors/keyboards in ICU 2, a pathogen known to cause hospital-acquired infections and possibly exhibiting complex resistance patterns, e.g. vancomycin-resistant strains. The failure of disinfection 10:11 in this case is most likely because of the applied manual disinfection, which is prone to failure. However, we were not able to assess the individual cleaning performance. In a large multicenter, randomised trial, a cleaning bundle (REACH) showed promising results in reducing especially enterococcal infections [29] . The implementation of such bundles in ICUs might probably lead to less nosocomial infections in critically ill patients and warrants investigation in further trials. Coagulase-negative staphylococci were detected in the majority of the swabbed locations. These bacteria are known to be associated with human skin and mucosa and can be a source for infections of foreign bodies or indwelling catheters [30] . It remains speculative, whether the finding of these bacteria in the disinfected ICUs has a clinical relevance with regard to the transmission of potentially harmful infections. The use of the hydrogen peroxide nebulisation technique has been shown to reduce bacterial burden on medical devices [31] . In the present study, we did not analyse the effectiveness of this technique as compared to control locations without its use. However, we were not able to culture bacteria in the areas where hydrogen peroxide nebulisation was used. This supports the possible role of hydrogen peroxide as a useful adjunct for ICU disinfection. Another advantage of this technique is the operator-independence. Strengths of this study are the structured and comprehensive viral/bacterial sampling of different objects and its pragmatic design during COVID-19 pandemics reflecting everyday situations in ICUs with possibly relevant impacts on patient outcomes. Furthermore, the single-blinded study design ensured the investigation of regular cleaning quality. Our study has several limitations. First, the ICUs were cleaned and disinfected by numerous employees of the ICU department and facility management. As a consequence, different parts of the facilities were probably not cleaned uniformly or in the same intensity. However, this fact reflects daily real-life work processes in hospitals. Second, the investigators could not verify if the objects actually had been cleaned or had been omitted owing to human factors such as overlooking or ignoring. Third, the analysed objects differed in shape and size, which might have influenced the swabbing technique. Fourth, no cluster-randomisation could be performed between the two ICU subunits due to time-constraints and urgent demand for ICU beds. Finally, due to the dynamic of the pandemic in our hospital, both ICUs were not swabbed and tested as a baseline prior to cleaning and disinfection and the timing of the swabbing was not randomly performed. This should be taken into account in future studies with a similar design. In conclusion, several bacteria possibly leading to colonisation or infections of critically ill patients were cultured from swabs taken from disinfected ICUs after the COVID-19 pandemic. SARS-CoV-2 RNA was not detected on any of the swabbed objects further supporting that conventional disinfection is sufficient to safely repurpose COVID-19 ICUs to routine ICUs despite the contagious nature of the disease. Bacterial and fungal coinfection in individuals with coronavirus: a rapid review to support COVID-19 antimicrobial prescribing Rates of co-infection between SARS-CoV-2 and other respiratory pathogens Clinical course and outcomes of critically ill patients with SARS-CoV-2 pneumonia in Wuhan, China: a single-centered, retrospective, observational study Clinical predictors of mortality due to COVID-19 based on an analysis of data of 150 patients from Wuhan, China Prognostic factors associated with mortality risk and disease progression in 639 critically ill patients with COVID-19 in Europe: Initial report of the international RISC-19-ICU prospective observational cohort Clinical course and risk factors for mortality of adult inpatients with COVID-19 in Wuhan, China: a retrospective cohort study Bacterial contamination of inanimate surfaces and equipment in the intensive care unit Healthcare equipment as a source of nosocomial infection: a systematic review Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR Euro surveillance: bulletin Europeen sur les maladies transmissibles Bacterial colonization of handheld devices in a tertiary care setting: a hygiene intervention study Severe acute respiratory syndrome coronavirus 2 RNA contamination of inanimate surfaces and virus viability in a health care emergency unit Detection of air and surface contamination by SARS-CoV-2 in hospital rooms of infected patients Pseudomonas aeruginosa in hospital sinks Carbapenem-resistant enterobacteriaceae dispersal from sinks is linked to drain position and drainage rates in a laboratory model system Multidrug-resistant Pseudomonas aeruginosa outbreaks in two hospitals: association with contaminated hospital waste-water systems Effects of a disinfection device on colonization of sink drains and patients during a prolonged outbreak of multidrug-resistant Pseudomonas aeruginosa in an intensive care unit Control of endemic multidrug-resistant Gram-negative bacteria after removal of sinks and implementing a new water-safe policy in an intensive care unit Sources of sporadic Pseudomonas aeruginosa colonizations/infections in surgical ICUs: Association with contaminated sink trap Healthcare outbreaks associated with a water reservoir and infection prevention strategies Self-disinfecting sink drains reduce the Pseudomonas aeruginosa bioburden in a neonatal intensive care unit Role of Stenotrophomonas maltophilia in hospital-acquired infection Stenotrophomonas maltophilia: an emerging opportunist human pathogen Klebsiella spp. as nosocomial pathogens: epidemiology, taxonomy, typing methods, and pathogenicity factors Nosocomial colonization and infection by Achromobacter xylosoxidans The epidemiology of carbapenem-resistant enterobacteriaceae: the impact and evolution of a global menace Multiresistant Enterobacter cloacae outbreak in an intensive care unit associated with therapeutic beds The association between colonization with carbapenemase-producing enterobacteriaceae and overall ICU mortality: an observational cohort study Reduced rate of intensive care unit acquired gram-negative bacilli after removal of sinks and introduction of "water-free An environmental cleaning bundle and health-care-associated infections in hospitals (REACH): a multicentre, randomised trial Coagulase-negative staphylococci Disinfecting noncritical medical equipment-effectiveness of hydrogen peroxide dry mist as an adjunctive method Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations