key: cord-1013052-pyaulwpc authors: Tobisch, Adrian; Springsklee, Lukas; Schäfer, Lisa-Franziska; Sussmann, Nico; Lehmann, Martin J.; Weis, Frederik; Zöllner, Raoul; Niessner, Jennifer title: Reducing indoor particle exposure using mobile air purifiers - experimental and numerical analysis date: 2021-07-25 journal: bioRxiv DOI: 10.1101/2021.07.23.453308 sha: 394da0a8b37fbacd2e03cdbd77a103a98a016658 doc_id: 1013052 cord_uid: pyaulwpc Aerosol particles are one of the main routes of transmission of COVID-19. Mobile air purifiers are used to reduce the risk of infection indoors. We focus on an air purifier which generates a defined volumetric air flow through a highly efficient filter material. We investigate the transport of aerosol particles from an infected dummy equipped with an aerosol generator to receiving thermal dummies. For analysis, we use up to 12 optical particle counters to monitor the particle concentration with high spatial resolution. Based on the measurement data, a computational fluid dynamics (CFD) model is set up and validated. The experimental and numerical methods are used to investigate how the risk of infection suggested by the particle exposure in an exemplary lecture hall can be reduced by a clever choice of orientation of the air purifier. The particle concentration at head height deviates by 13 % for variations of location and orientation. Finally, CFD simulation was used to monitor the particle fates. The steady simulation results fit quite well to the experimental findings and provide additional information about particle path and for assessing comfort level due to air flow. Practical implications Different installation locations and operating conditions of the air purifier are evaluated and the use of thermal dummies mimics the conditions of practical use cases. The measurement results show the integral particle mass over time in the “faces of the dummies”, representing the potentially inhaled particle load of persons present in the room. At an air change per hour of 5, the cumulated PM1 mass at head level was reduced by 75 %, independently of the location of the infected dummy, compared to the “natural decay” case showing that filtration is an effective means of reducing aerosol particle concentrations. It turns out that obstructing the outlet stream of the air purifier may be particularly advantageous. The COVID-19 pandemic has implied large restrictions to public and private life and 56 has far-reaching eects on society, culture, science, and the economy. It is well-known 57 that a major route of infection with SARS-CoV-2 is the transmission by aerosol-borne 58 viral pathogens [1] . These virus-laden aerosols may be emitted when talking, shouting, 59 singing, coughing, sneezing or simply breathing. Small aerosol particles may remain Mobile air puriers represent a chance to reduce aerosol particle concentration by removing 90 particles from the air using highly ecient lters. For this purpose, ACH of 5 to 6 are 91 recommended [6, 8] . Multiple studies have investigated the decay rates of aerosol particle 92 concentration using air puriers at varied ACH. Burgmann et al. [9] showed that at an ACH 93 of 6 the aerosol particle concentration is reduced by approximately 80 % within 30 minutes. Since the air velocity is larger at the outlet than at the intake, the puried air is discharged 102 at greater distance [11] . On account that aerosol particles move with bulk air [12] , this 103 presents a chance for the air purier to disperse the aerosol particles throughout the 104 room, rather than removing them. [13] showed that the clean air delivery rate (CADR) 105 of an air purier in a small room of 70 m³ is by and large independent of its position. By placing the air purier in a particular disadvantages position the decay rate of the 107 particle concentration and therefore the CADR decreased [13]. The CADR is determind from Equation (1) by measuring the reduction rate k purif ier of 109 aerosol particles (particle size ranging from 0,09 µm to 11 µm) taking the natural decay 110 rate k natural into account in a standardized test chamber V room [14] , while the ACH is 111 calculated by the volumetric ow rate of the air purier divided by the room volume. This 112 4 entails that although the ACH of a particular air purier is in line with recommendations 113 the CADR can be greatly reduced by a disadvantageous installation. Investigation of the eectiveness of air puriers in reducing indoor aerosol particle con-115 centration often combine experimental and numerical methods. This allows for the ex-116 amination of multiple cases using validated CFD models while minimizing experimental 117 eort. Multiple studies have modeled the transport of aerosol particles indoors. In these 118 publications various results of the importance of humidity and the thermal eects to a 119 numerical particle simulation are discussed. 120 Feng et al. [1] showed that the most numerical studies report that condensation and 121 evaporation due to humidity have a negligible eect on the particle distribution. the source to the air cleaner, like when using common ltrating air puriers. The literature review shows investigations of the general dispersion of aerosols in dierent 152 rooms and under dierent conditions. However, the studies do not focus on the particle 153 load that the persons are exposed to at their seat positions. Therefore, in this study 154 we investigate the particle concentration at positions where particles may be inhaled by 155 persons using a high spatial resolution. Therefore, the purpose of this work is to 157 assess the inuence of the position and the orientation of an air purier on the 158 aerosol particle concentration within the room and to identify preferable cases. The total window area is 20 m², of which 6 m² can be used for ventilation. (2) the decay rate k purif ier at each measurement point is determined. Inuence of particle source on local particle exposure Lagrange approach and the Euler-Euler approach. In particle laden ows with a low mass 256 loading the Lagrangian approach is advantageous. It is assumed, that a mass point ap-257 proach with approximation of the forces by particle volume is sucient. Therefore, the 258 particles are assumed to be spherical. Due to the low mass loading of less than 10 %, an Index F represents uid parameters. The density is denoted by ρ and the ow velocity . with diameter d and the drag coecient C drag , which is calculated by the spherical drag 50 % of the initial particle concentration decay after (7, 52 ± 0, 09) min at an ACH of 5. Increasing the ACH to 10 gives a half-life time of (3, 63 ± 0, 04) min, while 99% of the 381 initial particle concentration decays after (24.6 ± 0.7) min. In all cases, the air purier reduces the particle load compared to the natural decay. This is slightly higher than the reduction determined in the rst experimental set-up, due 429 to the fact that emitting particles near the intake leads to an overall reduction of well The fates describe the number of particle streams arriving at a dened target boundary. The dierent labels represent the dierent particle source positions. The data series 479 represent the dierent locations of the air purier in Figure to achieve the best possible compromise between comfort due to air velocity and lter 509 volume ow. The air purier has to be oriented in such a way, that the outow area is not 510 directed towards occupied seats. In addition, by variation of the ACH, it can be shown 511 that the duration of the particle movement from the source to the air purier decreases 512 with higher ow rate. Depending on the air change rate, redirecting particles to the air 513 purier reduce the possible infectuous particle streams by more than 50 %. Relative number of streams The dierence of summer and winter simulation is mainly noticeable at the window side. The cold window glass in winter leads to sinking air ows. Directly below the window is and by studying the decay phase ("infected person has left the room") while using an 572 unrealistically high emission rate to cut the experiment short. Furthermore, we validated 573 a CFD model based on the measurements in order to study particle fates and to allow for 574 the investigation of situations, which can hardly or not be considered experimentally. Overall, the results stress that ltration is an eective means of reducing aerosol parti-576 cle concentrations. The measurements suggest that a blowout against the wall may be 577 particularly advantageous in order to avoid an increase of local particle concentration at 578 the locations where persons breathe after turning on the air purier. In turns out that 579 the air purier can very eectively reduce aerosol particle concentrations in a combined 580 loading and decay scenario by 86 % using a good orientation with obstructed outlet and 581 by 61 % in an unfavorable orientation and position. The CFD simulations suggest that an 582 additional eect of risk mitigation is the fact that the air purier reduces the deposition of 583 aerosol particles on critical surfaces (persons, furniture). However, it needs to be stressed 584 that aerosol exposure and particle fates may dier from the actual infection risks due to 585 system-inherent dierences such as the fact that inhaled particles are removed in reality, 586 but remain within the system in the models and in the experiments. Further work needs to be done to provide insight into the fact how the specic ow con-588 guration inuences the results. Therefore, this study should be extended taking into 589 account dierent air purier devices. In addition, it needs to be investigated to which 590 extend the results obtained depend on the specic geometry of the lecture hall and in how 591 far they can be generalized. List of Figures 593 17 606 7. left-hand side: PM1 exposure at face height in the absence of the air puri-607 er; right-hand side: PM1 exposure at face height for the positions SW-W 608 and SW-S depending on the aerosol source (29,46,80) at an ACH of 5 . . . 19 609 8. Comparison of vortex structures in slow ow regions on dierent meshes of Lagrange particles using steady particle tracking for valida-611 tion with measurement data Inuence of wind and relative humidity on 624 the social distancing eectiveness to prevent covid-19 airborne transmission: a numerical 625 study, eng Argentum 47: so hilft silber gegen das corona-virus, Die römer paracelsus und heutige mediziner und untersuchungen zur wirkung 628 von nano silber gegen bakterien und viren, de la Fuente Briones, Raúl (Verfasser) (Books 629 on Demand Charakterisierung biogener sekundärer organischer aerosole mit statistis-631 chen methoden, Zugl.: Wuppertal, Univ., Diss., 2010, ger Indoor environmental quality 638 Predicted infection risk for aerosol transmission of sars Ventilation of health care facilities Energetische bewertung von gebäuden -642 lüftung von gebäuden -teil 3 Können mobile raumluftreiniger eine indirekte 644 sars-cov-2 infektionsgefahr durch aerosole wirksam reduzieren?, de Transmission and reduction of aerosols in classrooms 646 using air purier systems, eng Testing mobile air puriers in a school classroom: 649 reducing the airborne transmission risk for sars-cov-2 Prevention of exposure to and spread of covid-19 using air puriers: challenges 652 and concerns, eng, Epidemiology and health 42 Review of indoor aerosol generation, 654 transport, and control in the context of covid-19, eng, International forum of allergy 655 & rhinology 10 Testing of an indoor air cleaner for particulate pollutants under realistic conditions in 659 an oce room Method for measuring performance 661 of portable household electric room air cleaners Numerical investigation of the 663 interaction, transport and deposition of multicomponent droplets in a simple mouth-664 throat model The role of the combined use of experimental and computational methods in reveal-667 ing the dierences between the micron-size particle deposition patterns in healthy and 668 asthmatic subjects simultaneous measurement of the 671 temporal and local development of particle concentrations of dierent source strengths 672 in closed indoor rooms applying a highly ecient mobile air lter An overview of experiments and nu-675 merical simulations on airow and aerosols deposition in human airways and the role 676 of bioaerosol motion in covid-19 transmission On airborne virus transmission in elevators and conned 679 spaces, eng Numerical investigation 682 of aerosol transport in a classroom with relevance to covid-19, eng Aerosol particles generated by coughing and sneezing of a sars-cov-2 685 (covid-19) host travel over 30 m distance Sur-688 vival of expiratory aerosols in a room: study using a bi-compartment and bi-component 689 indoor air model Survival of 691 aerosolized coronavirus in the ambient air, eng A 694 novel methodology and new concept of sars-cov-2 elimination in heating and ventilating 695 air conditioning systems using waste heat recovery, eng, AIP advances 10 Assess-698 ing the ltration eectiveness of a portable ultraviolet air cleaner on airborne sars-cov-2 699 laden droplets in a patient room: a numerical study Fundamentals of multiphase heat transfer and ow Numerische strömungsberechnung, Schneller einstieg in ansys cfx 18 durch 706 einfache beispiele, ger, 4., überarbeitetete und aktualisierte Auage Aspects of computer simulation of liquid-fueled com-709 bustors Lüftung von nichtwohngebäuden allge-714 meine grundlagen und anforderungen für lüftungs-und klimaanlagen und raumkühlsys-715 teme Cfd predictions of indoor air movement induced by cold 717 window surfaces DIN Deutsches Institut für Normung e.V