key: cord-1011351-kzkhrbq7 authors: Martínez-Gallo, Mónica; Esperalba-Esquerra, Juliana; Pujol-Borrell, Ricardo; Sandá, Víctor; Arrese-Muñoz, Iria; Fernández-Naval, Candela; Antón-Pagarolas, Andrés; Cardona, Victoria; Labrador-Horrillo, Moisés; Pumarola-Suñé, Tomás; Hernandéz-González, Manuel title: Kits comercializados para evaluar la respuesta celular T frente a péptidos S del SARS-CoV-2. Un estudio piloto en trabajadores sanitarios date: 2021-09-25 journal: Med Clin (Barc) DOI: 10.1016/j.medcli.2021.09.013 sha: 669dd897fd79acd5d4929f8d706caf986d9604e2 doc_id: 1011351 cord_uid: kzkhrbq7 Introducción: Es fundamental evaluar los niveles de protección inmune en infectados o tras la vacunación frente a SARS-CoV-2. La medición de la respuesta inmune celular T puede complementar la determinación de anticuerpos. Nuestro objetivo fue evaluar la viabilidad de un ensayo comercial validado de respuesta celular T. Métodos: Se incluyeron veinte trabajadores sanitarios (TS). Medimos anticuerpos contra proteínas N y S de SARS-CoV-2 en paralelo con un ensayo de liberación de interferón-gamma (IFNγ) en sangre completa (IGRA) para péptidos de la proteína S. IFNγ se determinó mediante dos métodos de detección: CLIA y ELISA. Resultados: IGRA detectó respuesta celular T en TS tanto infectados como vacunados. La correlación de los dos métodos de detección de IFNγ fue muy alta (R>0,8) y la sensibilidad y la especificidad variaron entre 100 y 86% y 100-73% respectivamente. Hubo una concordancia muy alta entre los niveles de anticuerpos específicos y el ensayo IGRA aunque la correlación cuantitativa fue relativamente baja. En el pequeño grupo de infectados, una dosis de vacuna fue suficiente para alcanzar la meseta de respuesta inmune. IGRA fue claramente positivo en un profesional vacunado inmunosuprimido que presentaba anticuerpos contra la proteína S negativos. Conclusiones: IGRA frente a péptidos de la proteína-S es susceptible de automatización y constituye una herramienta prometedora para medir la respuesta inmune celular frente a SARS-CoV-2; es aplicable a un gran número de muestras y puede servir para valorar la protección, particularmente en los grupos vulnerables en riesgo de volver a exponerse a la infección, como los TS. Background: It is crucial to assess the levels of protection generated by natural infection or SARS-CoV-2 vaccines, mainly in individuals professionally exposed and in vulnerable groups. Measuring T-cell responses may complement antibody tests currently in use as correlates of protection. Our aim was to assess the feasibility of a validated assay of T-cell responses. Methods: Twenty health-care-workers (HCW) were included. Antibody test to SARS-CoV-2 N and S-proteins in parallel with a commercially available whole-blood-interferon-gamma-release-assay (IGRA) to S-peptides and two detection methods, CLIA and ELISA were determined. Results: IGRA test detected T-cell responses in naturally exposed and vaccinated HCW already after first vaccination dose. The correlation by the two detection methods was very high (R>0.8) and sensitivity and specificity ranged between 100 and 86% and 100-73% respectively. Even though there was a very high concordance between specific antibody levels and the IGRA assay in the ability to detect immune response to SARS-CoV-2, there was a relatively low quantitative correlation. In the small group primed by natural infection, one vaccine dose was sufficient to reach immune response plateau. IGRA was positive in one, with Ig(S) antibody negative vaccinated immunosuppressed HCW illustrating another advantage of the IGRA-test. Conclusion: Whole-blood-IGRA-tests amenable to automation and constitutes a promising additional tool for measuring the state of the immune response to SARS-CoV-2; they are applicable to large number of samples and may become a valuable correlate of protection to COVID-19, particularly for vulnerable groups at risk of being re-exposed to infection, as are health-care-workers. Es fundamental evaluar los niveles de protección inmune en infectados o tras la vacunación frente a SARS-CoV-2. La medición de la respuesta inmune celular T puede complementar la determinación de anticuerpos. Nuestro objetivo fue evaluar la viabilidad de un ensayo comercial validado de respuesta celular T. Se incluyeron veinte trabajadores sanitarios (TS). Medimos anticuerpos contra proteínas N y S de SARS-CoV-2 en paralelo con un ensayo de liberación de interferón-gamma (IFNγ) en sangre completa (IGRA) para péptidos de la proteína S. IFNγ se determinó mediante dos métodos de detección: CLIA y ELISA. IGRA detectó respuesta celular T en TS tanto infectados como vacunados. La correlación de los dos métodos de detección de IFNγ fue muy alta (R>0,8) y la sensibilidad y la especificidad variaron entre 100 y 86% y 100-73% respectivamente. Hubo una concordancia muy alta entre los niveles de anticuerpos específicos y el ensayo IGRA aunque la correlación cuantitativa fue relativamente baja. En el pequeño grupo de infectados, una dosis de vacuna fue suficiente para alcanzar la meseta de respuesta inmune. IGRA fue claramente positivo en un profesional vacunado inmunosuprimido que presentaba anticuerpos contra la proteína S negativos. IGRA frente a péptidos de la proteína-S es susceptible de automatización y constituye una herramienta prometedora para medir la respuesta inmune celular frente a SARS-CoV-2; es aplicable a un gran número de muestras y puede servir para valorar la protección, particularmente en los grupos vulnerables en riesgo de volver a exponerse a la infección, como los TS. It is crucial to assess the levels of protection generated by natural infection or SARS-CoV-2 vaccines, mainly in individuals professionally exposed and in vulnerable groups. Measuring Tcell responses may complement antibody tests currently in use as correlates of protection. Our aim was to assess the feasibility of a validated assay of T-cell responses. Twenty health-care-workers (HCW) were included. Antibody test to SARS-CoV-2 N and Sproteins in parallel with a commercially available whole-blood-interferon-gamma-release-assay (IGRA) to S-peptides and two detection methods, CLIA and ELISA were determined. IGRA test detected T-cell responses in naturally exposed and vaccinated HCW already after first vaccination dose. The correlation by the two detection methods was very high (R>0.8) and sensitivity and specificity ranged between 100 and 86% and 100-73% respectively. Even though there was a very high concordance between specific antibody levels and the IGRA assay in the ability to detect immune response to SARS-CoV-2, there was a relatively low quantitative correlation. In the small group primed by natural infection, one vaccine dose was sufficient to reach immune response plateau. IGRA was positive in one, with Ig(S) antibody negative vaccinated immunosuppressed HCW illustrating another advantage of the IGRA-test. Whole-blood-IGRA-tests amenable to automation and constitutes a promising additional tool for measuring the state of the immune response to SARS-CoV-2; they are applicable to large number of samples and may become a valuable correlate of protection to COVID-19, particularly for vulnerable groups at risk of being re-exposed to infection, as are health-care-workers. One of the groups with the highest incidence of COVID-19 in the present pandemic has been Health Care Workers (HCW). In the last month of 2020, a worldwide vaccination campaign against SARS-CoV-2 began and, front line Health-Care-Workers (HCWs) have been among the first group receiving the new vaccines. As part of the adaptive response to infection, humans generate SARS-CoV-2-specific-antibodies and specific T-lymphocytes (1) . Several studies on acute and convalescent COVID-19 patients have demonstrated that SARS-CoV-2-specific T cell responses control viral replication and reduce disease severity (2) . Anti-spike (S) and antinucleocapsid (N) proteins IgG antibodies are associated with greatly reduced risk of SARS-CoV-2 reinfection in the 6 months after COVID-19 (3). S-antigen-mRNA-based-vaccines against SARS-CoV2 (Pfizer-BioNTech and Moderna) have demonstrated immunogenicity (typically evaluated by serology) with 95% efficacy without major safety issues in all phases of human trials (4).) Although clinical trial data of vaccines in use are excellent in terms of effectiveness, real-world evidence remains scarce. One issue arisen in the health system -as in other essential sectors-is how to reassure HCWs, especially those pertaining to vulnerable groups e.g., diabetics, that, after overcoming COVID-19 or vaccination, they are reasonably protected and can reassume their duties. Here we present a pilot study of SARS-CoV-2 specific antibody and T-cell responses to spikeprotein (S) after mRNA-vaccination in a small group of HCWs at Hospital Universitari Vall d'Hebron (HUVH) using one commercially available test suitable for clinical laboratories, amenable to automation and therefore applicable to a large number of samples. Twenty HCWs of HUVH were recruited as part of a longitudinal study of seroprevalence and clinical impact of COVID-19 HUVH, a major academic hospital with over 6500 staff. All Data were analyzed by non-parametric tests; Mann-Whitney test for comparisons between the COVID and NO-COVID groups, and Friedman test for comparisons between paired values, and correlation studies to compare variables was calculated by Pearson correlation coefficient. GraphPad Prism v8.01 software was used for both statistical analysis and graphical representation. At enrolment COVID group participants (n=5) had detectable IgG (N) antibodies while those in the NO-COVID group, (n=15) were all negative, thus excluding the presence of asymptomatic cases in the latter group ( Figure 1A Figure 1B) as if they had reached their plateau (see also Figure 2 ). Results from IFN-γ production to Ag1 and Ag2 S-peptides measured by CLIA are in Figure 1C and D and by ELISA in E and F. The correlation of CLIA and ELISA readings was almost total (R>0.9) in all cases. Cut-off points for each variant of the IGRA assay were calculated by ROC analysis with the following results: CLIA cut-off point was > 0.051 IU IFN-gamma/ml with a sensitivity of 86.6% and specificity of 100% for Ag1 and > 0.44 IU IFN-gamma/ml for Ag2 with a sensitivity 100% and a specificity 73.3% (Figure 3 ). The cut-off point for the ELISA was >0.13 IU IFN-gamma/ml for Ag1 with a sensitivity of 85.7% and specificity 100% and for Ag2 >0.12 IU IFN-gamma/ml with a sensitivity of 92.8% and a specificity of 100%. Correlation between Ag1 and Ag2 results was very high (R=0.88 for ELISA and 0.84 for CLIA (data not shown). In general, Ag2 induced higher responses than Ag1, and. A positive response to either of the two peptides pools should be considered, in principle a positive result. From these results, it is not clear the need of using the Ag1 pool of peptides, but this may be different in a larger group with a more diverse genetic background. Overall, quantitative correlation between the antibody and T-cell responses was low (R in the order of 0.2) (Figure 4 ) but there was a good concordance in detecting the immune response to Spike. Sensitivity of the IGRA test may be superior in this group to IgG(S) antibody test due to the presence of one anti-CD20 treated participant (see below, illustrative case 12), but due to the small size, conclusions cannot be drawn. Interestingly four of the five post COVID group did not respond in the IGRA test prior to vaccination, but one dose was sufficient to reach good levels of IFN-γ production, indicating priming by the natural infection. Second dose rather reduced the response, perhaps because due to the time elapsed since priming, response contracted more quickly, this reduction has now been reported in a recent paper of Lozano Ojalvo et al (7) and in other not yet peer reviewed reports (8) . In the NO-COVID group even if the first dose already induced a significant response, the boost vaccination was required to reach a response like that of the COVID group after first dose. 9 In this small study, we did not find any relation of antibody nor T-cell responses to spike proteins with the total lymphocytes, their main subsets, or the immunoglobulin levels. There was a trend for antibody and T-cell responses to be lower in older patients ( Figure 5 ), no gender effect was detected. As mentioned above one of the NO-COVID patients, case 12, was treated with anti-CD20 for an autoimmune condition and did not develop IgG or IgM antibodies after vaccination. Interestingly a clearly measurable T-cell responses was detected (see Figure 2 tick case) after vaccination and a small expansion of circulating of plasmablasts in sequential samples. We detected plasmablasts after the vaccine boost with few pre class switch B lymphocytes prior to vaccination despite anti-CD20 treatment, indicating residual capacity of the B-cell compartment ( Figure 6 ). Another NO-COVID group patient, case 19, was infected the same day that she received first dose of vaccination. The patient developed T-cell response in the IGRA-assay, and in this case, in addition to antibodies to the S antigen, she developed antibodies to N-antigen ( Figure 1A , dot with asterisk), but the response was like the NO-COVID group indicating that being primed by two simultaneous stimuli did not result in this case in a supranormal response. We have studied in parallel antibody and cellular response to the BNT162b2-mRNA-COVID-19vaccine in a small group of HCW and found that the IGRA-assays yields rapid results that are concordant with antibody tests and could constitute a valuable contribution to the evaluation of the immune response in people that may need to be reassured of being protected against SARS-CoV2 infection. This is, however, a small pilot study that should be expanded to really demonstrate that SARS-CoV-2 spike IGRA based tests can constitute valuable correlates of protection complementary to serology. It has already been shown that protein N is the most immunogenic structural protein and that IgG responses to protein-S in SARS-CoV-2 are lower, possibly due to the glycosylation state of this protein (9) . This may explain that IGRA and IgG(S) antibody tests were negative in two of the participants in the COVID group that were IgG(N) positive. However, after immunization with a single dose, they responded to a level higher than fully vaccinated NO-COVID participants. Lozano-Ojalvo D et al in a recent paper also demonstrate that, while the second dose of the BNT162b2 vaccine increases both the humoral and cellular immunity in naive individuals, COVID-19 recovered individuals reach their peak of immunity after the first dose (7) . There are a good number of studies demonstrating T-cell responses to SARS-CoV-2 using techniques (2) widely applied to measure responses to other viral infection (10, 11) . These techniques include intracellular-cytokine-staining (ICS) by flow cytometry and variations of the ELISPOT-assay which measure mainly IFN-γ production. Activation-induced markers (AIM), also by flow cytometry, can be a sensitive technique (12) . However, they have limitations in the applicability compared with whole blood IGRA-assays used here when it comes to using them in a clinical laboratory (13) . Availability of a complementary correlate of protection in addition to serology may be invaluable for two groups, 1) HCW and other professionals with vulnerability factors that need to be reassured of being immunized against SARS-CoV-2 before reassuming tasks that have a risk of accidental re-exposure, and 2) for immunosuppressed patients that fail to make a measurable antibody response. IGRA spike peptides test may constitute a very valuable tool in this context as it can be applied to a large number of samples producing results in 24h and with promising sensitivity and specificity. Significance of the differences, *p<0.05, **p<0.01, ***p<0.001, ****p<0.0001. COVID-19 and the Path to Immunity Antigen-Specific Adaptive Immunity to SARS-CoV-2 in Acute COVID-19 and Associations with Age and Disease Severity Antibody Status and Incidence of SARS-CoV-2 Infection in Health Care Workers COVID-19 vaccines: comparison of biological, pharmacological characteristics and adverse effects of Pfizer/BioNTech and Moderna Vaccines Extended immunophenotyping reference values in a healthy pediatric population Age-specific pediatric reference ranges for immunoglobulins and complement proteins on the Optilite TM automated turbidimetric analyzer Differential effects of the second SARS-CoV-2 mRNA vaccine dose on Tcell immunity in naive and COVID-19 recovered individuals T-cell and antibody responses to first BNT162b2 vaccine dose in previously SARS-CoV-2-infected and infection-naive UK healthcare workers: a multicentre, prospective, observational cohort study Analysis of the SARS-CoV-2 spike protein glycan shield reveals implications for immune recognition José María Aguado et al. SARS-CoV-2-Specific Cell-Mediated Immunity in Kidney Transplant Recipients Recovered from COVID-19 Severe SARS-CoV-2 patients develop a higher specific T-cell response Targets of T Cell Responses to SARS-CoV-2 Coronavirus in Humans with COVID-19 Disease and Unexposed Individuals A whole blood test to measure SARS-CoV-2-specific response in COVID-19 patients The authors want to express their gratitude to participants of the study and laboratory technicians from Microbiology and Immunology for technical assistance. We thank Qiagen and Diasorin® for commercial kits donation, these companies do not participate in the experimental plan, data analysis nor in writing this manuscript. English writing support was provided by Fidelma Greaves.This study was funded in part by Instituto de Salud Carlos III, grant COV20/00416 co-financed by the European Regional Development Fund (ERDF). The authors declare that they have no conflict of interest.