key: cord-1009763-4f6fdfo7 authors: Persson, Inger; Östling, Andreas; Arlbrandt, Martin; Söderberg, Joakim; Becedas, David title: A Machine Learning Sepsis Prediction Algorithm for Intended Intensive Care Unit Use (NAVOY Sepsis): Proof-of-Concept Study date: 2021-09-30 journal: JMIR Form Res DOI: 10.2196/28000 sha: 49aa25022f9392da5335ca5bae26f4e8b65cb2ee doc_id: 1009763 cord_uid: 4f6fdfo7 BACKGROUND: Despite decades of research, sepsis remains a leading cause of mortality and morbidity in intensive care units worldwide. The key to effective management and patient outcome is early detection, for which no prospectively validated machine learning prediction algorithm is currently available for clinical use in Europe. OBJECTIVE: We aimed to develop a high-performance machine learning sepsis prediction algorithm based on routinely collected intensive care unit data, designed to be implemented in European intensive care units. METHODS: The machine learning algorithm was developed using convolutional neural networks, based on Massachusetts Institute of Technology Lab for Computational Physiology MIMIC-III clinical data from intensive care unit patients aged 18 years or older. The model uses 20 variables to produce hourly predictions of onset of sepsis, defined by international Sepsis-3 criteria. Predictive performance was externally validated using hold-out test data. RESULTS: The algorithm—NAVOY Sepsis—uses 4 hours of input and can identify patients with high risk of developing sepsis, with high performance (area under the receiver operating characteristics curve 0.90; area under the precision-recall curve 0.62) for predictions up to 3 hours before sepsis onset. CONCLUSIONS: The prediction performance of NAVOY Sepsis was superior to that of existing sepsis early warning scoring systems and comparable with those of other prediction algorithms designed to predict sepsis onset. The algorithm has excellent predictive properties and uses variables that are routinely collected in intensive care units. Sepsis is a life-threatening clinical syndrome caused by dysregulated host response to infection [1] . Sepsis and the inflammatory response that ensues can lead to multiple organ dysfunction syndrome and death. It has been estimated that sepsis is present in 6% of adult hospital admissions [2] and in approximately one-third of intensive care unit (ICU) patients [3] . Globally, it affects approximately 49 million people every year [4] . During the coronavirus disease 2019 (COVID- 19) pandemic, sepsis was the most frequently observed complication among adult inpatients at Jinyintan Hospital and Wuhan Pulmonary Hospital (Wuhan, China) who had been discharged or had died (as of January 31, 2020) [5] . There is a continuum of severity, ranging from sepsis to septic shock. Although wide-ranging and dependent upon study Early recognition of sepsis can be difficult due to its syndromic nature and patient heterogeneity. Early recognition is further complicated by the lack of reliable blood-or plasma-based biomarkers. Hundreds of biomarkers have been tested as prognostic markers in sepsis [12] [13] [14] ; however, none has demonstrated sufficient specificity or sensitivity to be routinely used in clinical practice [12] . In this context, there exists a significant unmet medical need to assist clinicians with identifying hospitalized patients at risk of developing sepsis. Today, sepsis diagnosis is made by combining information from clinical examinations performed by health care professionals and information provided from monitoring devices and laboratory data (ie, based on empirical clinical decision rules). This procedure is both time-consuming and subjective (ie, heavily dependent upon the skills and experience of the doctor or nurse). Timely intervention is critical for patients with sepsis, yet with the manual routines used at present, there is a risk of delayed diagnosis of sepsis and initiation of treatment. Given that ICU clinicians are inundated with ever-increasing amounts of data collected at higher and higher resolution, machine learning prediction algorithms have gained increased interest in research and clinical practice because of their potential to improve early detection and adherence to treatment protocols and decrease time to antibiotic administration, which have been proved to improve clinical outcomes [6] [7] [8] [9] . Fleuren et al [15] and Moor et al [16] reviewed previously developed sepsis prediction algorithms; however, they found that very few had been prospectively evaluated in clinical practice, and those that had been, were evaluated in the United States to date. To date, and to the best of our knowledge, only 1 ICU algorithm is available for clinical use [17, 18] , and another is planned to be prospectively validated [19] . The purpose of this proof-of-concept study was to develop a machine learning algorithm for early prediction of which patients in ICUs will develop sepsis within coming hours, using clinical data routinely collected in electronic health records. The algorithm for prediction of sepsis was developed based on Massachusetts Institute of Technology Lab for Computational Physiology MIMIC-III Clinical Database [20] . This database contains demographic, vital sign, laboratory test, medication, and other data for 38,597 adult ICU patients (61,532 ICU stays), for whom data were collected between 2001 and 2012. At the time of algorithm development, the newer MIMIC-IV data were not available. Sepsis was defined by Sepsis-3 criteria [1] , which require a suspected infection and an increase in Sequential Organ Failure Assessment score of at least 2 points. Suspected infection [21] was defined as instances when antibiotics had been prescribed and when body fluid cultures were present in the electronic health record within a specific time window; if a culture is ordered within 24 hours after antibiotics, or antibiotics had been prescribed less than 72 hours after a culture order, the time of suspected infection was determined to be the earlier of these two. Sepsis-relevant antibiotics and body fluids were chosen as the indicators based on methods used by Liu et al [22] -they used blood cultures and a defined list of antibiotics (presented in the code repository referred to in their paper). A patient was considered septic if their Sequential Organ Failure Assessment score had increased by at least 2 points within the time window from 48 hours before to 24 hours after the time of suspected infection, and the time of sepsis onset was defined as the time of the 2-point increase. All patients not fulfilling Sepsis-3 criteria were defined as the nonsepsis cohort. The code used for assigning sepsis labels is available upon request. Patients included ( Figure 1 ; Table 1 ) in the analysis had at least 1 measurement of each of the variables included in the algorithm and were at least 18 years of age at the time of admission. Patients receiving antibiotics before ICU admission and patients with an International Statistical Classification of Diseases, ninth revision, (ICD-9) code that matched a sepsis diagnosis but for whom Sepsis-3 criteria were not met at any time during the ICU stay were not included. The latter can occur, for example, when the patient already had received a sepsis diagnosis at admission. No time stamps are available; therefore, diagnosis cannot be confirmed retrospectively. Differences between sepsis and nonsepsis cohorts were assessed using an appropriate test of statistical significance (Welch t test for numerical variables; the Fisher exact test or chi-square test for categorical variables). ICU stays logged using the CareVue (Philips) electronic health record system were excluded, that is, only ICU stays logged using the Metavision (iMDSoft) electronic health record system were included, since negative blood cultures are underreported with CareVue, which means that suspicion of infection is underrepresented in these patients [17] . The algorithm used the following 20 variables: age, gender, heart rate, respiratory rate, temperature, systolic blood pressure, diastolic blood pressure, vasopressor use, serum creatinine, glucose, lactate, platelets, white blood cell count, blood urea nitrogen, bilirubin, pH, oxygen saturation pulse oximetry, fraction of inspired oxygen, International Normalized Ratio, and Glasgow Coma Scale. Hourly values were used, and a last observation carried forward approach was used for single missing data points. For any hours with more than 1 measurement, hourly averages were used. Variable selection for the algorithm was conducted in cooperation with medical professionals to ensure that spurious variables were excluded and the most important variables were included. Any additional feature engineering was deemed unnecessary and was left for the network to discover. The algorithm was developed using convolutional neural networks [23] . This method was chosen based on its ability to handle time series data. Data were preprocessed using R (The R Project), and the models were executed using TensorFlow [24, 25] backend in Python (version 3.7.6) via Jupyter Notebooks (version 6.0.3). The model has 2 convolutional layers, the first with 10 filters, the second with 5 filters, each of size (1,2) where 1 is the variable domain and 2 is the time domain. The filter walks across the variables one by one, looking at each pair of time points for that variable. The convolutional layers are followed by 4 fully connected layers of size 50, 25, 15, 10, respectively, before feeding into the final output layer. Dropout with parameter 0.5 is performed between each layer, both convolutional and fully connected. The batch size for training was 512. Training continued until the training loss had not improved in the last 1000 epochs (early stopping), after which the weights with the lowest training loss were saved. A cyclical learning rate was used [26] (with initial learning rate: 1e-4, maximal learning rate: 1e-3, step size: 16 * number of training examples). Different parts of the training data were used for development and internal validation of the algorithm in order to avoid overfitting. Random onset matching [16] -randomly chosen 4-hour sequences, with the last time point up to 3 hours before onset, for patients with sepsis, or at any point during the whole ICU stay, for patients without sepsis-was used. The time points were sampled from a β(10,1) distribution, with ranges for patients without sepsis scaled to match those of their entire stay. The β parameters were chosen to place higher weights early in their stay. Data were sampled to maintain a prevalence of sepsis of 20% in both training and test data, to resemble the prevalence of sepsis in ICU patients in North America and Western Europe [3] . This also facilitated comparisons between training and test data, since area under the receiver operating characteristic curve (AUROC), area under the precision-recall curve (AUPRC), and accuracy are affected by prevalence. A prediction horizon of 3 hours was chosen based on the availability of data at different time points; at earlier time points, there were considerably fewer ICU stays with data for all variables of interest. In a similar study, data imputation was performed for early time points with missing data, for example, by copying the first available data to earlier time points [17] ; however, this technique would be impossible to use in a live setting; thus, it was not used in our study. The training data consisted of 7681 sequences (n=2593 ICU stays) of 4-hour data (sepsis: n=1385 sequences, nonsepsis: n=6296 sequences), and internal validation during training was performed on 633 sequences of 4-hour data (n=200 ICU stays). The final algorithm was externally validated using the second part of the data (hold-out test data, ie, data that were not used in development of the algorithm; n=95 ICU stays, n=152 sequences of 4-hour data). Performance of the algorithm was compared with a number of illness severity risk scores currently used in clinical practice to predict sepsis in the same time frame (for a summary of sepsis early warning scoring systems, see Postelnicu et al [27] and Rosenqvist [28] ). The following scores were included in this study: Systemic Inflammatory Response Syndrome criteria, at least 2 of 4 criteria present [29] ; Quick Sepsis-Related Organ Failure Assessment score, at least 2 of 3 criteria present [1] ; Sepsis-Related Organ Failure Assessment score, total score ≥2 [1]; Modified Early Warning Score, score ≥5 [30] ; National Early Warning Score 2, score ≥ 5 [31] ; Rapid Emergency Triage and Treatment System, highest priority level [32] ;Sepsis Alert [28] ; and Prehospital Early Sepsis Detection score, score ≥4 [33] . Predictions were computed at the same time points as those of the algorithm. Receiver operating characteristics, that is, the proportions of true positives (sensitivity) relative to the proportions of false positives (1 -specificity), were calculated to assess performance. Based on the receiver operating characteristics curve, an operating point (threshold) was chosen for classification of patients with high risk of developing sepsis. True positives were patients with sepsis that were accurately identified by the algorithm up to 3 hours before the onset of sepsis, and false positives were patients without sepsis that were incorrectly identified by the algorithm to be at risk of developing sepsis. The operating point for the algorithm was chosen to keep a sensitivity (proportion of true positives) of approximately 0.80 and a higher specificity (proportion of true negatives), in order to minimize the false alert rate while still keeping a high sensitivity. Ideally, an algorithm should yield a high proportion of true positives and a low proportion of false positives, which corresponds to a large AUROC. The AUPRC is also of importance-a large area represents both high recall (low false negative rate) and high precision (low false positive rate). High scores for both recall and precision demonstrate accurate results (high precision) and mostly positive results (high recall). Accuracy is the proportion of correct predictions. Positive predictive value is the proportion of predicted sepsis cases that are true sepsis cases). Further information about accuracy, sensitivity, and specificity can be found in Multimedia Appendix 1. The AUROC for the algorithm was as high as 0.90 on internally validated training data ( Table 2 ) and 0.84 on hold-out test data, for predictions 3 hours before onset ( Table 3 ). The AUPRC was 0.62 on training data ( Table 2 ) and as high as 0.68 on test data, for predictions 3 hours before onset ( Table 3 ). The algorithm's sensitivity, specificity, and accuracy were higher than those for any of the comparison risk scores ( Table 2, Table 3 , Figure 2 , and Figure 3 ). In external validation (Table 3) , sensitivity values for predictions 3 hours before onset were higher than those at any of the time points closer to onset. This was expected, since NAVOY Sepsis was optimized to make predictions as early as possible. The operating point produced a positive predictive value of 0.57 on training data (Table 2) , and 0.50 on test data, for predictions 3 hours before onset (Table 3) . This metric was expected to be lower than sensitivity, specificity, and accuracy, due to the severe class imbalance. A sensitivity of 85% produces 15% false positives; since the majority of patients did not have sepsis, sepsis will be overpredicted. When comparing the distribution of sepsis predictions made by the algorithm with the actual distribution of sepsis (prevalence), the algorithm predicted that 28% of patients had sepsis in training data ( Table 2 ) and 27% to 29% of patients had sepsis in test data (Table 3) , which is somewhat larger than the prevalence of 20%. Only 1% (4/405) of the patients with sepsis included in the data set had antibiotics administered before or at the time of sepsis onset, which confirms that there is a need for NAVOY Sepsis as an early detection system. Almost no patients had complete data, which is similar to clinical use situations. The algorithm was designed to be integrated with electronic health record systems primarily in Europe (CE marked as Software as a Medical Device) and is currently being evaluated in what is expected to be the largest prospective randomized clinical trial of a machine learning sepsis prediction algorithm to date (ClinicalTrials.gov; NCT04570618). The algorithm has excellent predictive properties, outperforms existing early warning scoring systems, and is comparable to previously published algorithms [17, [34] [35] [36] designed to predict sepsis onset for ICU patients in accordance with the Sepsis-3 criteria. The algorithm uses 4 hours of input from routinely collected variables to make sepsis predictions. This means that only a few hours after ICU admission, the clinical staff can receive high-performance risk assessment for sepsis in adult patients. Moor et al [16] point out that it can be difficult to compare studies due to measures such as AUROC or accuracy as they are directly affected by sepsis prevalence. In unbalanced situations, such as in the case of sepsis prediction, where the proportion of patients without sepsis is substantially larger than the proportion of patients with sepsis, the AUPRC should be reported. The AUPRC of NAVOY Sepsis is, to the best of our knowledge, substantially higher than that shown by any comparable sepsis prediction algorithm to date (ranging between 0.04 and 0.60) [17, [34] [35] [36] . The algorithm provides accurate results (high precision) and returns a majority of all positive results (high recall). The AUROC curve is high, which means that NAVOY Sepsis yields a high proportion of true positives and a low proportion of false positives. The AUROC of NAVOY Sepsis is higher than those of many sepsis early warning scoring systems, evaluated using the same data. The AUROC of NAVOY Sepsis is also higher than those of all previously published algorithms (ranging between and 0.74 and 0.85) [17, 19, [36] [37] [38] but one [39] , noting, however, the abovementioned comparability issues. Only Futoma et al [35] used a comparable sepsis prevalence (21%), with other prevalences ranging between 6% and 9% (or not specified) [17, 19, [36] [37] [38] . Only 1 sepsis prediction model [39] had a higher AUROC (as high as 0.97; AUPRC not presented) than that of NAVOY Sepsis. Wickramaratne and Mahmud [39] state that their model "has an advantage over the traditional methods in terms of using new data to improve performance. Further, the model can include new features when they become available." In other words, their model [39] seems to be a self-learning model, which would be the first of its kind if used in practice. The paper describes the technical aspects of their proposed model well but does not discuss how to implement the model into clinical practice [39] . Obtaining regulatory clearance in Europe, in the form of a CE mark, for self-learning software for use in health care is not an easy task. However, Wickramaratne and Mahmud's algorithm [39] , as many of the other previous attempts described in the literature [36] [37] [38] , is based on a number of laboratory tests not routinely performed in European ICUs and would thus not be relevant for the European Union market. NAVOY Sepsis is based only on variables that are routinely measured in European ICUs and was developed in collaboration with medical professionals to ensure that it will be applicable to clinical practice. This study has some limitations. First, the algorithm was developed using retrospective data and has not yet been evaluated prospectively. As Moor et al [16] wisely point out, "only the demonstration of favorable outcomes in large prospective randomized controlled trials will pave the way for machine learning models entering the clinical routine." Second, even though matching of sepsis onset time for patients without sepsis was used in order to prevent bias caused by differences in the length of stay distribution, other types of bias might be present. For example, performance metrics were affected by the prevalence of sepsis, and even though the prevalence was set at 20% to enable direct comparisons with early warning scores, it is difficult to compare our findings with those in previously published research. Third, it would have been valuable to test the performance of the algorithm with an additional external validation cohort, for example, data from the PhysioNet Challenge [38] or the eICU Collaborative Research Database [40] . However, the PhysioNet Challenge data do not contain all the variables of interest, and the eICU data only contain a few patients with information on all of the variables and thus could not be used for this purpose. It should, however, be noted that external validation was performed in this study (on hold-out test data). Fourth, this study does not provide information on the clinical or economic impact of the integration of the developed algorithm in clinical practice. The accuracy, sensitivity, and specificity of the algorithm developed in this proof-of-concept study are to potentially be validated in a prospective randomized clinical trial (ClinicalTrials.gov; NCT04570618). That study also intends to further explore the developed algorithm's integration into clinical workflow and effect on relevant clinical outcomes. In addition, a health economic study is currently being undertaken where the cost-effectiveness of implementation of the developed algorithm in European ICUs is being explored. Finally, when deploying the algorithm at different institutions, it will be important to evaluate its performance by, for example, using an initial period without presenting the predictions, to allow for a comparison of the predictions and sepsis onset and thereby enable adjustment of the threshold to ensure that the algorithm will work as expected at each institution. Also, with access to data from different institutions, the algorithm can be retrained and continuously improved or adjusted to work well in different settings (regions, hospitals, populations). Sepsis remains a leading cause of mortality and morbidity in ICUs worldwide. Early detection is key to effective management and patient outcome, as there is no specific sepsis treatment available. We have developed a high-performance machine learning sepsis prediction algorithm that outperforms existing early warning scoring systems. The algorithm is based on variables routinely collected and readily available in electronic health records in ICUs of all categories and may provide an opportunity for enhanced patient monitoring, earlier detection of sepsis, and improved patient outcomes. If the findings in this study are validated in the upcoming prospective randomized clinical trial, this algorithm has the potential to be the first CE-marked sepsis prediction algorithm for commercial use in European ICUs. The third international consensus definitions for sepsis and septic shock (sepsis-3) CDC Prevention Epicenter Program. Incidence and trends of sepsis in US hospitals using clinical vs claims data Sepsis in intensive care unit patients: worldwide data from the intensive care over nations audit Global, regional, and national sepsis incidence and mortality, 1990-2017: analysis for the Global Burden of Disease Study Clinical course and risk factors for mortality of adult inpatients with COVID-19 in Wuhan, China: a retrospective cohort study Duration of hypotension before initiation of effective antimicrobial therapy is the critical determinant of survival in human septic shock Time to administration of antibiotics among inpatients with severe sepsis or septic shock Early diagnosis of sepsis in emergency departments, time to treatment, and association with mortality: an observational study Time to treatment and mortality during mandated emergency care for sepsis Empiric antibiotic treatment reduces mortality in severe sepsis and septic shock from the first hour: results from a guideline-based performance improvement program Surviving sepsis campaign: international guidelines for management of sepsis and septic shock Sepsis biomarkers: a review Biomarkers of sepsis Biomarkers of sepsis: time for a reappraisal Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy Early prediction of sepsis in the ICU using machine learning: a systematic review Prediction of sepsis in the intensive care unit with minimal electronic health record data: a machine learning approach Effect of a machine learning-based severe sepsis prediction algorithm on patient survival and hospital length of stay: a randomised clinical trial An interpretable machine learning model for accurate prediction of sepsis in the ICU MIMIC-III, a freely accessible critical care database. Sci Data Assessment of clinical criteria for sepsis: for the third international consensus definitions for sepsis and septic shock (sepsis-3) Data-driven discovery of a novel sepsis pre-shock state predicts impending septic shock in the ICU ImageNet classification with deep convolutional neural networks TensorFlow: large-scale machine learning on heterogeneous distributed systems TensorFlow: a system for large-scale machine learning Sepsis early warning scoring systems: the ideal tool remains elusive! Sepsis Alert -a triage model that reduces time to antibiotics and length of hospital stay Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis Validation of a modified early warning score in medical admissions National Early Warning Score (NEWS) 2: standardising the assessment of acute-illness severity in the NHS Medical Emergency Triage and Treatment System (METTS): a new protocol in primary triage and secondary priority decision in emergency medicine An early warning scoring system to identify septic patients in the prehospital setting: the PRESEP score Early recognition of sepsis with Gaussian process temporal convolutional networks and dynamic time warping An improved multi-output Gaussian Process RNN with real-time validation for early sepsis detection Graph convolutional networks-based noisy data imputation in electronic health record An explainable artificial intelligence predictor for early detection of sepsis Early prediction of sepsis from clinical data: the PhysioNet/Computing in Cardiology Challenge Bi-directional gated recurrent unit based ensemble model for the early detection of sepsis The eICU Collaborative Research Database, a freely available multi-center database for critical care research. Sci Data We thank Fredrik Sjövall, MD at Skåne University Hospital, for valuable discussions about sensitivity, specificity, and current practice at Swedish ICUs. The work was funded by the Swedish innovation agency Vinnova, and cofunded by AlgoDx AB and the Department of Statistics at Uppsala University. DB, JS, and IP conceived the idea. IP and AÖ designed the computational framework. AÖ designed the model and performed the computations, and IP verified the analytical methods. MA aided in discussions and interpretations. DB and JS were involved in planning and supervising the work. IP and MA drafted the manuscript, and all authors discussed the results and contributed to the final manuscript.