key: cord-1003818-p9ok4rjo authors: Li, Fang; Chang, Chun-Hao; Chung, Yu-Chun; Wu, Huey-June; Kan, Nai-Wen; ChangChien, Wen-Sheng; Ho, Chin-Shan; Huang, Chi-Chang title: Development and Validation of 3 Min Incremental Step-In-Place Test for Predicting Maximal Oxygen Uptake in Home Settings: A Submaximal Exercise Study to Assess Cardiorespiratory Fitness date: 2021-10-13 journal: Int J Environ Res Public Health DOI: 10.3390/ijerph182010750 sha: 01c1dd56bdda13c81e482e5d9952b3ad9fc7507a doc_id: 1003818 cord_uid: p9ok4rjo The purpose of this research was to develop the 3 min incremental step-in-place (3MISP) test for predicting maximal oxygen uptake ([Formula: see text] O(2max)). A total of 205 adults (20–64 years) completed the 3MISP and [Formula: see text] O(2max) tests. Using age, gender, body composition (BC) including percent body fat (PBF) or body mass index (BMI), and with or without heart rate (HR) at the beginning of exercise (HR0) or difference between HR at the third minute during the exercise and the first minute post exercise (ΔHR3 − HR4) in the 3MISP test, six [Formula: see text] O(2max) prediction models were derived from multiple linear regression. Age (r = −0.239), gender (r = 0.430), BMI (r = −0.191), PBF (r = −0.706), HR0 (r = −0.516), and ΔHR3 − HR4 (r = 0.563) were significantly correlated to [Formula: see text] O(2max). Among the six [Formula: see text] O(2max) prediction models, the PBF model(∆HR3 − HR4) has the highest accuracy. The simplest models with age, gender, and PBF/BMI explained 54.5% of the [Formula: see text] O(2max) in the PBF model(BC) and 39.8% of that in the BMI model(BC). The addition of HR0 and ∆HR3 − HR4 increases the variance of [Formula: see text] O(2max) explained by the PBF and BMI models(∆HR3 − HR4) by 17.98% and 45.23%, respectively, while standard errors of estimate decrease by 10.73% and 15.61%. These data demonstrate that the models established using 3MISP-HR data can enhance the accuracy of [Formula: see text] O(2max) prediction. The purpose of this research was to develop the 3 min incremental step-in-place (3MISP) test for predicting maximal oxygen uptake ( . VO 2max ). A total of 205 adults (20-64 years) completed the 3MISP and . VO 2max tests. Using age, gender, body composition (BC) including percent body fat (PBF) or body mass index (BMI), and with or without heart rate (HR) at the beginning of exercise (HR0) or difference between HR at the third minute during the exercise and the first minute post exercise (∆HR3 − HR4) in the 3MISP test, six . VO 2max prediction models were derived from multiple linear regression. Age (r = −0.239), gender (r = 0.430), BMI (r = −0.191), PBF (r = −0.706), HR0 (r = −0.516), and ∆HR3 − HR4 (r = 0.563) were significantly correlated to . VO 2max . Among the six . VO 2max prediction models, the PBF model ∆HR3 − HR4 has the highest accuracy. The simplest models with age, gender, and PBF/BMI explained 54.5% of the . VO 2max in the PBF model BC and 39 .8% of that in the BMI model BC . The addition of HR0 and ∆HR3 − HR4 increases the variance of In the past, many scholars have devoted themselves to the analysis of aerobic capacity using the submaximal exercise intensity method [1] [2] [3] . With the public awareness of physical health increasing under the impact of novel coronavirus disease 2019 , at-home workouts have become a pandemic fitness trend. An easy-to-use and low-cost method for self-monitoring of cardiorespiratory fitness (CRF) level is essential for most people. CRF is a primary component of physical fitness [4, 5] . The assessment of CRF may help individuals to identify their risk of cardiovascular disease, providing a basis for developing home workout plans, and it may be adopted as a clinical indicator to evaluate a patient's functional status and treatment outcomes [6] [7] [8] . Maximal oxygen uptake ( . VO 2max ) is a crucial factor in physical performance and health conditions. The plateau in . VO 2 , attained at exhaustion during the incremental . VO 2max exercise test, represents the upper limit of CRF [9] . Direct measurement of . VO 2max requires the participant to perform an exercise test on a treadmill or bicycle ergometer until exhaustion while being monitored with a gas exchange analyzer. However, this direct measurement of . VO 2max relies on highly precise laboratory technology, expensive equipment, complicated operating procedures, intense physical exercise, and appropriate trained personnel to operate the test system. It is also a very time-consuming procedure. In addition, the measurement equipment is stationary, which limits the feasibility of home testing or wide application. Therefore, during the COVID-19 pandemic and increase in home workouts, it is essential to develop a method for indirect measurement of . VO 2max suitable for home testing, which could contribute to the development of self-health management in the public. Exercise tests are important clinical tools for evaluating CRF status and predicting future cardiovascular events [10] . Previous studies have developed various submaximal exercise tests, including the 6 minute walk test, 12 min walk test, Cooper 12 min run test, and the multistage 20 m shuttle run test. Based on the measured distance, speed, and other exercise data, as well as various physiological indicators of body composition, . VO 2max prediction equations were established to assess CRF levels in adults [11] [12] [13] . These exercise tests were relatively simple, required little equipment, and entailed lower management costs. However, they required large testing spaces and long performance sessions, and they were easily influenced by weather. In addition, exercise commonly induces physiological stress, but these tests did not monitor physiological variables. As a result, it was difficult to identify whether the participant reached a state of willpower failure, which is prone to increasing the risk of sudden cardiac arrest in participants with low levels of physical fitness. This would also affect to some extent the effectiveness of . VO 2max prediction equations and limit the feasibility of testing in home settings. To overcome the time and space limitations in CRF field-based exercise tests, several researchers proposed the use of step-up tests to evaluate CRF levels in adults [14] [15] [16] [17] . Based on the relationship between oxygen consumption in the human body and the post-exercise heart rate (HR) during recovery, they established the . VO 2max prediction equation with a combination of demographic parameters (such as age-, gender-, and body-fat-related values) to access the CRF levels of participants, and the outcomes were considerable. The step-up test is one of the most commonly used indirect methods of measurement for estimating CRF [14, 16, 17] . This type of method requires little space, a short testing time, and no expensive equipment or professionals to operate it. However, some studies found that, during the step-up test, elderly adults and obese individuals were not able to satisfactorily complete the testing procedure at a standard intensity of exercise [6, 18] . The step-up test is performed with a step-box with a height of 20-50 cm, so individual differences in fitness level could easily be ignored. For a participant who is overweight or has a knee injury, gait abnormality, or balance impairment, it may be difficult to complete the test. The step-in-place test may be a suitable alternative to the step-up test. The step-inplace test requires less testing time, space, and equipment. Since it requires no step-box, it is safer than the step-up test. It is also easier to manage and perform in home settings. According to the step-in-place test protocol, the participant lifts the knees to a target height, defined as midway between his/her midpoint of the patella and iliac crest, while standing [2, 19] . Currently, the step-in-place test is widely applied in the assessment of aerobic fitness in elderly people (aged 60-94 years), but few studies have examined CRF tests in younger adults. To enhance the safety, effectiveness, and universality of adult CRF tests, with selective and economic considerations, we aimed to develop the 3 min incremental step-in-place ( VO 2max . Subsequently, the predicted residual error sum of squares (PRESS) and constant error (CE) statistical methods were adopted separately to cross-validate these prediction equations. These study procedures were approved by the Institutional Review Board of the Industrial Technology Research Institute. Before beginning the experimental tests, informed consent forms were completed by the participants. All the participants (Taiwanese adults) were recruited openly, independently, and randomly through public advertisements posted in public spaces. Participants with cardiovascular, pulmonary, or metabolic disorders, or muscular or bone diseases that could affect their completion of the exercise tests, were excluded. Finally, a total of 205 healthy adults (aged 20-64 years, 48.8% women and 51.2% men) completed this research project. The anthropometric and body composition parameters that were measured included height, body weight, BMI, and PBF. A body composition analyzer (InBody ® 570, Biospace, Inc., Seoul, Korea) was used for the measurements of body weight and PBF [20] . BMI was calculated as weight (in kilograms) divided by height (in meters) squared. The . VO 2max of each participant was measured with an electromagnetically braked bicycle ergometer and a cardiopulmonary exercise testing system. During the exercise test, the participant was required to wear a Polar H10 Hear Rate Monitor with a chest strap to monitor his/her HR and an appropriate gas-collecting mask (Hans Rudolph). The sampling tube and digital flow sensor connected to the mask were used to measure the tidal volume of each breath and the composition of O 2 and CO 2 . The initial load at the beginning of the test on the bicycle ergometer was 25 W. The load was increased by 15 W every 2 min until the participant could not maintain the required pedaling rate of 70 rpm. Participants were then asked to rate their levels of physical fatigue on the Borg Rating of Perceived Exertion scale (RPE, scale range: 6-20 points). In the present research, . VO 2max refers to the maximum average relative . VO 2 value for 30 consecutive seconds. The . VO 2max criteria were deemed to be met when the participants reached three of the following four requirements: (1) a plateau in . VO 2 despite an increase in load; (2) respiratory exchange ratio ≥ 1.10; (3) maximum HR over 90% of the age-predicted maximum HR (i.e., 220 − age); and (4) RPE ≥ 18 [21] . Before the 3MISP test, the participant was required to wear a Polar H10 Hear Rate Monitor with a chest strap to monitor his/her HR during exercise. While wearing the HR monitor, the patient stood while the midway point between the participant's patella and iliac crest was measured as the target height for lifting the knees and marked by colored tape. Once the test began, the participant was asked to match a rhythm produced by an electronic metronome while stepping in place, raising the knee to the marked height with each step. The 3MISP test started with 96 steps per minute (SPM), and the rate was increased by 24 SPM every 1 minute. If the participant was unable to maintain the rhythm, he/she could run instead of walking for up to 3 min. If the participant was unable to lift the knees to the required height or follow the rhythm for 30 s, then the test session was terminated and the results were eliminated from the analysis. For safety concerns, the participant had to maintain the step rate at 80 SPM for a cool-down period of 30 s before resting in a standing position. The recorded data contained the HR at the beginning of exercise (HR0); at the first (HR1), second (HR2), and third minutes (HR3) during the exercise; and at the first minute post exercise (HR4). All values are presented as mean ± standard deviation (SD). Multivariate analysis of variance was used to compare the differences in physical characteristics between the training and testing groups. The effect size was calculated to reflect the magnitude of between-group differences in the total values for various variables, using Cohen's d [22] .Pearson's correlation coefficients were calculated to analyze the linear relationships between independent variables (i.e., age, gender, PBF, BMI, and 3MISP-HR) and the measured . VO 2max of the training group, and the validity of . VO 2max prediction models was also verified. For absolute values of the correlation coefficient (r), 0.00-0.10 is regarded as negligible, 0.10-0.39 as weak, 0.40-0.69 as moderate, 0.70-0.89 as strong, and 0.90-1.00 as very strong correlation [23] . Multiple linear regression analysis with cross-validation (70% of the samples were used for modeling, and 30% of the samples were used for verification) was applied to the development of . VO 2max prediction models by using the variables of age, gender, PBF/BMI, and with or without 3MISP-HR. The multiple coefficient of determination (R 2 ), the absolute SEE, and relative SEE (%SEE) were used for evaluating the accuracy of the . VO 2max prediction equation, while the paired t-test was used to compare the difference between the measured . VO 2max and estimated . VO 2max in the training group. The PRESS and constant error ( VO 2max ) statistical methods were adopted separately to cross-validate the . VO 2max prediction models [3, 24] . According to the CRF classifications ( . VO 2max ) from the American College of Sports Medicine's guidelines for exercise testing and prescription, the entire sample was divided into the subgroups of gender, age, and . VO 2max [21] , and then the CEs were calculated to compare the differences between the measured and estimated . VO 2max among these subgroups. Bland-Altman plots were applied to assess the agreement between the predicted and directly measured . VO 2max values [25] . The statistical software SPSS (version 22, IBM Corp., Armonk, NY, USA) was used for statistical analysis. The significance level was set to p < 0.05. Table 1 presents the study population and the physical characteristics of all participants in the training and testing groups. The results of multivariate analysis of variance showed that there were no significant differences in age, height, body weight, BMI, PBF, HR0, or ∆HR3 − HR4 between the training and testing groups. Average . VO 2max was higher in the training group than in the testing group. VO 2max and independent variables in the training group. The results showed that age (r = −0.239, p = 0.004), BMI (r = −0.191, p = 0.022), PBF (r = −0.706, p < 0.001), and HR0 (r = −0.516, p < 0.001) all had significant negative correlations with . VO 2max , while gender (women = 0, men = 1) and ∆HR3 − HR4 both had positive correlations with . VO 2max (gender: r = 0.430, p < 0.001; ∆HR3 − HR4: r = 0.563, p < 0.001). Table 4 shows the results of cross-validation with the CE statistical method in the V Notes: BC, body composition; PBF, percent body fat; BMI, body mass index; HR0, heart rate at the beginning of exercise; ΔHR3 − HR4, difference between heart rate at the third minute during the exercise and the first minute post exercise in the 3MISP test. Table 4 shows the results of cross-validation with the CE statistical method in the . VO 2max prediction models. The CE absolute values for the subgroups of gender, age, and . VO 2max of 32-38 mL·kg −1 ·min −1 in the PBF and BMI models ∆HR3 − HR4 were less than 1. As for the . VO 2max subgroup, the CE absolute values for the subgroups of low physical fitness ( . VO 2max < 32 mL·kg −1 ·min −1 ) and high physical fitness ( . VO 2max ≥ 38 mL·kg −1 ·min −1 ) were higher, while the subgroup of moderate fitness ( . VO 2max = 32-38 mL·kg −1 ·min −1 ) had lower CE absolute values in all models. Previous studies have indicated that CRF is closely related to coronary heart disease, all-cause mortality [4, 27, 28] , and COVID-19 mortality [29] . Individuals with high CRF levels have lower risk of dying from COVID-19, while a low CRF level is likely to increase the risk of cardiovascular disease and mortality [30, 31] . For a CRF assessment, . VO 2max is generally considered as an indicator of CRF level. It can be used for clinical-related classification, such as risk stratification for patients with COVID-19 [32] . However, given the rapid spread of the severe COVID-19, the conventional method used to directly measure the . VO 2max on a treadmill or bicycle ergometer in the laboratory is not feasible. Therefore, it is necessary to develop a simple and reliable home testing method to indirectly measure VO 2max prediction equation based on their own conditions and circumstances to evaluate their CRF levels. Due to the simple movement, minimal space and equipment, short testing time, high safety index, and reliability, the 3MISP test is convenient for everyone to conduct CRF self-monitoring at home. Generally, HR can reflect an individual's physical fitness and exercise intensity. In a standard CRF test, the HR of a non-athlete is normally close to the age-predicted maximum HR [33] . An individual with a higher CRF level has a lower baseline HR and shorter HR recovery time following a cardiopulmonary exercise test [34] . Since there is a linear relationship between HR variations before, during, and after exercise and . VO 2max [2, 3, 6, 17, [35] [36] [37] [38] , the exercise HR test can improve the prediction of the . VO 2max model. Previous studies have demonstrated a significant negative correlation between post-exercise recovery HR and . VO 2max [6, 36, 37, 39] , and it is an important factor in . VO 2max prediction. Matsuo et al. (2020b) indicated that HR both during and following exercise had negative correlations with . VO 2max , and the HR index composed of these two had the largest correlation with . VO 2max [3] . Chung et al. (2021) found that the difference between HR at the third minute during the exercise and recovery HR at the first minute post exercise in the 3 min step test had positive correlations with . VO 2max [2] . The results of the present research are consistent with those of previous studies, demonstrating that ∆HR3 − HR4 and . VO 2max have a significant positive correlation in the 3MISP test, while HR0 has a negative correlation with . VO 2max (see Figure 1 ). These findings shows that HR can play a potential role in predicting Figure 2 ). These results show that, in the models developed on the basis of biological data, adding 3MISP-HR data improves the accuracy of . VO 2max prediction models, and the . VO 2max prediction of the PBF model ∆HR3 − HR has higher precision than that of the BMI model ∆HR3 − HR4 . Many previous studies of . VO 2max prediction have also found that PBF is a better predictor than BMI [2, 40, 41] . Therefore, when financial conditions permit, people can consider adopting the PBF models to evaluate their . VO 2max . As for economical options, the BMI models may be affordable choices. Due to the convenience of the step test, many studies in the past have adopted the Young Men's Christian Association step test [6, 16] , Harvard step test [42] , Chester step test [42] , and Japan step test [3] [3] . The step-up test requires the participant to continuously step forward onto and backward off a box of a specified height at a speed set by a metronome for a certain time to examine the CRF level according to the HR during or following exercise [43, 44] . Since this type of test places high demands on lower limb muscle strength, body coordination, and balance, it is difficult for participants with poor physical fitness or knee injuries to complete, and such participants are likely to fall during the stepping process [2] . Bohannon et al. (2015) noticed that 23% of their participants were unable to complete the step-up test, and those who could complete the procedure were younger adults (aged 39.9 ± 19.4 years) with lower BMI (25.0 vs. 27.1 kg/m 2 ) [18] . Beutner et al. (2015) also found that the participants who were unable to complete the test (15%) were older adults (aged 69.3 ± 5.5 years) or had higher BMI (BMI: 29.5 ± 3.9 kg/m 2 ) [6] . To enhance the safety, effectiveness, and universality of the CRF assessment, this research designed a substitute for the step-up test, namely the 3MISP test. The midway point between the participant's patella and iliac crest is measured as the target height for lifting the knees during the test, and no step-box is used. It is thus safer than the step-up test. VO 2max values predicted using gender, age, physical characteristics (BMI/PBF) and HR from the step test, and actual measurements of . VO 2max in the bicycle ergometer or treadmill test [2, 3, 16] and confirmed the applicability of 3MISP test to the healthy adults. For determining the reliability and validity of our . VO 2max prediction equations, two separate cross-validation procedures were performed in this research. The cross-validation results of the PRESS method showed that the R 2 (0.002-0.014) and SEE (0.018-0.2125 mL·kg −1 ·min −1 ) differences in the multiple linear regressions for the six prediction models between the training and testing groups were minor (see Table 3 ). Cross-validation analysis with the CE statistical method was used to compare the difference between measured and estimated . VO 2max in subgroups, and the results showed that the CE absolute values for the subgroups of gender, age, and . VO 2max of 32-38 mL·kg −1 ·min −1 in the PBF and BMI models ∆HR3 − HR4 were minor (see Table 4 ). The results of these two separate cross-validations verified the effectiveness of our . VO 2max prediction models. Therefore, the proposed 3MISP test and the . VO 2max prediction equations established in the present research are reasonable and feasible according to these experimental results. The practical implications are that HR during the 3MISP test can be used to predict . VO 2max , providing the assessment of CRF. By developing the . VO 2max models, the 3MISP test provides HR making it cost-effective and space-efficient to evaluate the CRF levels. The 3 min Harvard step was applied to measure the CRF levels in Taiwan, by calculating the step-up index with HR. This test requires step-up boxes, and participants with low physical fitness or knee injuries are prone to falling in the process of stepping forward onto and backward off the box [2] . Therefore, the safer test is pursued. Given that the HR is the key indicator of CRF, the implementation of the 3MISP test to calculate HR0 and ∆HR3 − HR4 provides a more securely practical method of CRF measurement, without a step-up box in the present study. Furthermore, we established six . VO 2max prediction models, and the public can choose the corresponding formulas based on economic conditions. Under specific conditions, individuals without a PBF detector can select more economical BMI models to estimate . VO 2max , thereby promoting the self-health management. There are some strengths and limitations in this research. The strengths are that the 3MISP test proposed for evaluating CRF is simple, safe, effective, space-saving, and easy to conduct. The cross-validation design was used to investigate the validity of 3MISP in predicting . VO 2max . In addition, the six prediction models can be chosen under different situations. Regarding limitations, no participants were given any habituation trial before the 3MISP test. Another limitation is that, since the participants in this research were all healthy adults in Taiwan aged 20-64 years, the . VO 2max prediction equation established here may not be applicable to children, adolescents, older adults, or individuals with metabolic syndrome or mobility impairments. The 3 min incremental step-in-place test has simple movements, a minimal testing space, a short testing time, a high safety index, and reliability, and it requires no step-box or expensive equipment. High demands on rhythm and coordination are limitations of 3 min incremental step-in-place test. This study showed that the 3 min incremental stepin-place test is an effective assessment method, and the accuracy of regression models for predicting maximal oxygen uptake was also improved. Among the six maximal oxygen uptake prediction models developed in the present research, the percent body fat model ∆HR3 − HR4 using age, gender, percent body fat, and heart rate at the beginning of exercise, and difference between heart rate at the third minute during the exercise and the first minute post exercise in the 3 min incremental step-in-place test, had the highest accuracy and appears to be the best model for maximal oxygen uptake prediction, whereas the body mass index models are more economical and affordable. Individuals can select appropriate maximal oxygen uptake prediction equations based on their own conditions and circumstances to evaluate their cardiorespiratory fitness levels. The 3 min incremental step-in-place test provides a safe, simple, and effective method of assessing cardiorespiratory fitness. It can be applied in the home setting as a cardiorespiratory fitness self-monitoring method for the general population. In the event that a rapid test is required and space is limited, the 3 min incremental step-in-place test can also be used as an ideal choice for clinical practice. The achievements of this study can provide health groups aged 20-64 years with various choices of cardiorespiratory fitness assessment, regardless of whether they own the necessary equipment. Validation of Submaximal Step Tests and the 6-Min Walk Test for Predicting Maximal Oxygen Consumption in Young and Healthy Participants Predicting maximal oxygen uptake from a 3-minute progressive knee-ups and step test Estimating cardiorespiratory fitness from heart rates both during and after stepping exercise: A validated simple and safe procedure for step tests at worksites. Graefe's Arch Importance of assessing cardiorespiratory fitness in clinical practice: A case for fitness as a clinical vital sign: A scientific statement from the american heart association Comparison Of Non-exercise Test and Step Test In Estimation of Aerobic Capacity (VO 2max ) In Young Adults Validation of a brief step-test protocol for estimation of peak oxygen uptake Estimating VO 2 peak from a nonexercise prediction model: The HUNT Study Cardiorespiratory fitness as a predictor of nonfatal cardiovascular events in asymptomatic women and men Incremental and decremental cardiopulmonary exercise testing protocols produce similar maximum oxygen uptake in athletes A simple step test to estimate cardio-respiratory fitness levels of rheumatoid arthritis patients in a clinical setting A means of assessing maximal oxygen intake. Correlation between field and treadmill testing The multistage 20 metre shuttle run test for aerobic fitness Submaximal exercise testing: Clinical application and interpretation Evaluating the validity and reliability of Harvard step test to predict VO 2max in terms of the step height according to the knee joint angle Variation of knee angle and leg length for predicting VO 2max in healthy male volunteers using the Queen's College step test The Validity of the YMCA 3-Minute Step Test for Estimating Maximal Oxygen Uptake in Healthy Korean and Vietnamese Adults Prediction of maximal oxygen consumption using the Young Men's Christian Association-step test in Korean adults. Graefe's Arch Six-minute walk test versus three-minute step test for measuring functional endurance Two-minute step test of exercise capacity: Systematic review of procedures, performance, and clinimetric properties Validating inbody®570 multi-frequency bioelectrical impedance analyzer versus DXA for body fat percentage analysis Clinical exercise testing and interpretation A power primer Correlation coefficients: Appropriate use and interpretation PRESS-related statistics: Regression tools for cross-validation and case diagnostics Understanding bland altman analysis VO 2 estimation equation accuracy to young adults Cardiorespiratory fitness as a quantitative predictor of all-cause mortality and cardiovascular events in healthy men and women: A meta-analysis The role of cardiorespiratory fitness on the risk of sudden cardiac death at the population level: A systematic review and meta-analysis of the available evidence The association of estimated cardiorespiratory fitness with COVID-19 incidence and mortality: A cohort study Higher cardiorespiratory fitness is strongly associated with lower cardiovascular risk factors in firefighters: A cross-sectional study in a German fire brigade Counteracting physical inactivity during the COVID-19 pandemic: Evidence-based recommendations for home-based exercise COVID-19-does exercise prescription and maximal oxygen uptake (VO 2max ) have a role in risk-stratifying patients? The relationship between maximum heart rate in a cardiorespiratory fitness test and in a maximum heart rate test Study of heart rate recovery and cardiovascular autonomic modulation in healthy participants after submaximal exercise A comparison between heart rate and heart rate variability as indicators of cardiac health and fitness Validity of Queen's College step test for use with young Indian men Validity of Queen's College Step Test for estimation of maximum oxygen uptake in female students A new submaximal cycle ergometer test for prediction of VO 2max . Scand Maximum oxygen uptake and cardiovascular response of Professional male football and Basketball players to Chester step test Workers' physical activity data contribute to estimating maximal oxygen consumption: A questionnaire study to concurrently assess workers' sedentary behavior and cardiorespiratory fitness Prediction of maximal oxygen uptake from a 3-minute walk based on gender, age, and body composition The effect of an active arm action on heart rate and predicted VO 2max during the Chester step test Review of Various Step Test Protocols for Use in Assessing Aerobic Fitness in Schools Determination of Cardiovascular Functioning in Chinese Adults with Intellectual Disabilities using the 3-Minute Step Test Informed Consent Statement: Informed consent was obtained from all subjects involved in the study. Before the experiment, the researchers explained the experimental process in detail, and the experiment began after the subjects signed the consent form. The authors declare no conflict of interest.