key: cord-1002434-q89l0w8i authors: Campos, Rafael K.; Jin, Jing; Rafael, Grace H.; Zhao, Mervin; Liao, Lei; Simmons, Graham; Chu, Steven; Weaver, Scott C.; Chiu, Wah; Cui, Yi title: Decontamination of SARS-CoV-2 and Other RNA Viruses from N95 Level Meltblown Polypropylene Fabric Using Heat under Different Humidities date: 2020-09-21 journal: ACS Nano DOI: 10.1021/acsnano.0c06565 sha: 1f2afb50dda0511af9b0cb8e85a719162467684b doc_id: 1002434 cord_uid: q89l0w8i [Image: see text] In March of 2020, the World Health Organization declared a pandemic of coronavirus disease 2019 (COVID-19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The pandemic led to a shortage of N95-grade filtering facepiece respirators (FFRs), especially surgical-grade N95 FFRs for protection of healthcare professionals against airborne transmission of SARS-CoV-2. We and others have previously reported promising decontamination methods that may be applied to the recycling and reuse of FFRs. In this study we tested disinfection of three viruses, including SARS-CoV-2, dried on a piece of meltblown fabric, the principal component responsible for filtering of fine particles in N95-level FFRs, under a range of temperatures (60–95 °C) at ambient or 100% relative humidity (RH) in conjunction with filtration efficiency testing. We found that heat treatments of 75 °C for 30 min or 85 °C for 20 min at 100% RH resulted in efficient decontamination from the fabric of SARS-CoV-2, human coronavirus NL63 (HCoV-NL63), and another enveloped RNA virus, chikungunya virus vaccine strain 181/25 (CHIKV-181/25), without lowering the meltblown fabric’s filtration efficiency. T he coronavirus disease 2019 (COVID-19) has affected millions of people globally and caused far-reaching impacts on public health and on the global economy. 1 The etiologic agent, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), a member of the family Coronaviridae, genus Betacoronavirus, subgenus Sarbecovirus, emerged in 2019. Its transmission is thought to take place through droplets and subsequently formed aerosols, generated when infected people sneeze, cough, speak, sing, and even breathe, or by contact between people or through fomites. 2−5 Data from influenza virus research revealed that aerosols generated by people can be classified into coarse (>5 μm) or fine (<5 μm) particles, and while coarse particles settle within 1 h, fine particles can remain suspended in the air for long periods of time when in poorly ventilated indoor environments; 6−8 in the case of SARS-CoV-2, it can remain infectious in fine particle aerosols for at least 16 h. 8 The virus particles contained in these aerosols can be inhaled to infect cells of the upper or lower respiratory tracts. 6, 7 The use of particulate filtering facepiece respirators (FFRs) is a form of personal protection that can minimize the inhalation of small airborne particles 9 by medical workers or other professionals at high risk of infection by SARS-CoV-2. Recent systemic studies demonstrate that facial coverings, including FFRs and masks, may reduce COVID-19 spread by 85% 10 and are a highly important mitigation measure. 5 FFRs of N95 or other highly filtering grade (e.g., FFP2, KN95, DS/DL2, and KF94) are able to filter 75 nm particles (median diameter) with >95% efficiency, which should provide sufficient protection against SARS-CoV-2, which measures ∼120 nm or larger in aerosol particles containing the virus. 11 The SARS-CoV-2 pandemic has led to shortages of personal protective equipment (PPE), including N95-grade FFRs (especially surgical-grade N95 FFRs among healthcare workers). To mitigate this issue, different methods were proposed to decontaminate these face masks and allow for safe reutilization: heat, 12−15 ultraviolet (UV) irradiation, 12, 16 steam, 17 ozone, 18 vaporized hydrogen peroxide (VHP), 19 chemical disinfectants, 12 and autoclaving. 20 Although some of these methods show promise, most can lead to a reduction in the meltblown's filtration efficiency or alteration in the physical fit of the FFR, 12, 16 making them potentially unsafe for repeated usage. In addition, the proposed decontamination methods that may not alter the physical properties of the FFR (filtration efficiency and fit) have varying levels of efficacy. For example, mild UV irradiation, which is an accessible and promising method for FFR decontamination when used within certain dosages, may have poor penetration when many layers of material are present. This raises the concern that the virus may be protected from inactivation if it penetrates deep into the layers of the FFR. 21 On the other hand, decontamination using moderate heat (<100°C) has emerged as one of the most promising methods to decontaminate FFRs during the COVID-19 pandemic because it causes little damage to the FFR 12, 22 and can be done in high throughput. While there is evidence that viruses can show considerable resistance to dry heat after being dried on surfaces, 23,24 detailed data are not consistently available for all viral families. For example, one study found that when influenza virus was dried on a stainlesssteel surface, heating was more effective at reducing viral infectivity when the humidity was high. 24 Heating influenza virus at 60°C for 15 min at 25% relative humidity (RH) resulted in a decrease of 1 log 10 -fold in viral titers, whereas the same heating process at 50% RH reduced viral titers by a factor of 4 log 10 -fold. 24 Although SARS-CoV-2 has been shown to be efficiently inactivated by heat in solution, 25 a comparison of inactivation by dry or moist heat when the virus is dried on surfaces has not been carried out, although one study found that stability of SARS-CoV-2 is lower in high humidity at common environmental temperatures (≤38°C). 26 To further address the relationship between humidity and virus susceptibility to heat inactivation, we tested heat inactivation protocols using three positive strand enveloped RNA viruses: SARS-CoV-2, human coronavirus NL63 (HCoV-NL63), and chikungunya virus, vaccine strain 181/25 (CHIKV-181/25). We tested infectivity of virus samples dried on meltblown fabric, before subjecting the samples to a treatment of temperatures (60−95°C) at either ambient (40− 60% RH) or 100% RH. FFRs of N95 or equivalent grade are usually composed of many layers of polypropylene nonwoven fabrics. Among the most important layers for its protective functionality is one produced by the meltblown process (i.e., meltblown nonwoven fabric), in which high velocity air blows a molten polymer, forming filaments that extend in different orientations and entangle in a web shape. When used in FFRs, this layer is electrostatically charged to significantly increase fabric's filtration capability for small particles, due to electrostatic adsorption. 12 We first visualized the structure of the meltblown fabric using scanning electron microscopy (SEM). Images of the meltblown fabric tested exhibited microfibers with diameters in the range of 2−10 μm that cross each other to form a three-dimensional porous structure ( Figure 1A ). The meltblown fibers are typically electrostatically charged to increase binding of particles, resulting in a much higher filtration efficiency without increasing the air resistance. To test the particle adsorption of the meltblown fibers, we used sodium chloride (NaCl) solution as an aerosol source (0.26 μm mass median diameter, 0.075 μm count median diameter) and loaded the NaCl aerosol onto the meltblown fabric. SEM images showed clear NaCl particles adsorbed onto the meltblown fibers ( Figure 1B and C). As the primary filtering material for small particles in FFRs, meltblown fabric was used to give a worst-case scenario for how the filtration efficiency changes as respirators are treated under various temperatures and humidities. Thus, if the meltblown fabric is observed to be unaffected by the treatment, it is not expected that all of an FFR's filtration properties would be affected. However, if the meltblown fabric's filtration properties are changed, this does not necessarily indicate that all of an FFR's filtration properties would be affected, as the full respirator has other supporting materials and is made up of multilayers, which can make it more robust. As there are multiple brands of FFRs with different meltblown fabrics and basis weights, some may be more robust than others. Evaluating the meltblown fabric alone, particularly a single layer, can give an indication of worst-case conditions. In addition, we only considered how the meltblown's filtration efficiency would change, but as FFRs also require proper fitting, it is possible that treatment conditions can alter the fit of FFRs. The data currently show that with respect to heat decontamination, it is unlikely to alter the fit of FFRs. 27 We used a meltblown fabric of 20 g/m 2 with initial efficiency around 95% (details given in the Methods section) to simulate how the filtration efficiency would change after application of heat for multiple treatment cycles. We first performed filtration efficiency testing after heat treatment of the meltblown fabrics under low humidity conditions (≤30%) to determine the upper limit of applicable heat. We observed no change in the filtration efficiency after treatment from 75 to 100°C, with up to 20 treatment cycles hovering around 95% filtration efficiency. However, we observed that heating at 125°C led to a sharp drop in the filtration efficiency at the fifth cycle, leading to a filtration efficiency of around 90%. In contrast to the filtration efficiency, we observed that the air resistance of the fabric ( Figure 2B ) did not vary when heat treatments of different temperatures were applied, which indicates that the physical structure and porosity of the material remained constant. Therefore, it is likely that high heat reduces the electrostatic charge on the meltblown fibers. This is not surprising, as polypropylene, the primary component of meltblown fabrics, has a melting point between 130−171°C. Thus, as the temperature approaches the melting point, the crystalline structure can become more relaxed, and it is possible that this will affect the filtration properties of the fabric through charge relaxation or other means. We determined that the upper limit of low humidity heat may be <100°C for treatment cycles ≤20 (cycle lengths are given in the Methods section for different temperatures). The data from these experiments are available in Supplementary Table S1 . As previously discussed, many viruses may have decreased viability in moist heat, so we also determined how the filtration efficiency would change under application of near 100% RH heat. As our previous work demonstrated that steam decreased the filtration efficiency, 12 we chose to test the moist heat treatments at 75, 85, and 95°C. Simulating 100% RH was performed by sealing the meltblown fabrics in polyethylene bags with 0.3 mL of water, not contacting the meltblown fabric (details in Methods section). For the samples tested at 75 and 85°C, we observed no significant changes in filtration efficiency for 20 treatment cycles compared to the initial value ( Figure 2C ). For the samples tested at 95°C, we observed that five cycles of temperature treatment did not affect the filtration efficiency ( Figure 2C ). However, by 10 cycles, the samples tested at 95°C decreased in filtration efficiency more than at the other two temperatures, although with a larger uncertainty as well (93.39 ± 2.33%) ( Figure 2C ). This filtration efficiency remains nearly constant and slightly decreases by 20 cycles (92.70 ± 2.62%) ( Figure 2C ). As previous measurements showed that steam from boiling water also significantly decreased the filtration efficiency to values as low as ∼80% by the tenth treatment cycle, 12 the decay observed at 95°C is not surprising and treatment cycles at this temperature should be limited to a minimum. It is possible that this decay is due to some adsorption of water or other mechanisms that can decay the electrostatic charge, as the air resistance also did not change under these conditions ( Figure 2D ), similar to the case for the low-humidity 125°C samples. Regarding the applicable temperatures, we can conclude that under low humidity (≤30% RH) temperatures of ≤100°C (20 cycles) did not significantly degrade the filtration efficiency. Under high humidity (∼100% RH) temperatures should be limited to ≤85°C (20 cycles) or ≤95°C (five cycles) to preserve the filtration efficiencies found in the meltblown fabrics we tested (Figure 2 and Supplementary Table S1 ). We next aimed to determine conditions of heat treatment and humidity that are efficient in inactivating SARS-CoV-2 loaded on the meltblown fabric. We mixed our virus stock 10:1 with either phosphate-buffered saline (PBS) or a bovine serum albumin (BSA) to a final concentration of 3 g/L, to mimic the conditions of bodily fluids such as sputum, 28−30 which contain higher protein concentrations than is found in the media used to create virus stocks; this is relevant because high protein concentrations are known to stabilize viruses, including SARS- CoV-2. 31 We allowed droplets containing SARS-CoV-2 (backtiter 1 × 10 6 PFU/sample) to dry on top of a piece of meltblown fabric in a biosafety cabinet for 2 h. These pieces were then added to a microcentrifuge tube that was incubated at an ambient RH of 60% on a heat block at 25, 60, and 75°C for 30 min, 85°C for 20 min, or 95°C for 5 min. The virus was then recovered by the addition of media followed by vortexing, from which we were able to recover approximately 1 × 10 5 PFU in the 25°C control condition. In the absence of BSA, heating the fabric at 60°C for 30 min resulted in a 2 log 10 -fold reduction in viral titers in comparison to 25°C for 30 min, whereas treatment at 75°C for 30 min reduced viral titers by 3.5 log 10 -fold and heating at 85°C for 20 min or 95°C for 5 min reduced the virus by 5 log 10 -fold, bringing the titers below the limit of detection (LOD) of the assay ( Figure 3A and Table 1 ). Our tests indicated that the addition of BSA stabilized the virus, as expected, and in these conditions the titers were reduced by 1 log 10 -fold at 60°C for 30 min, 3 log 10 at 75°C for 30 min, 4 log 10 -fold at 85°C for 20 min, and 5 log 10 -fold at 95°C for 5 min. Strikingly, virus could be detected in all of the conditions tested, although the 95°C treatments reduced the titers greatly and the amount of virus detected neared the LOD ( Figure 3A) . Air humidity is one factor that has generally been considered important for inactivation of dried viruses 23, 24 and should therefore be taken into account when performing heat inactivation studies. We therefore tested whether SARS-CoV-2 dried on meltblown fabric could be inactivated by heat at 100% RH. To achieve 100% RH, we added 100 μL of water to the bottom of each tube with the meltblown fabric, without touching the fabric. Using these moist heat conditions, we observed improved inactivation; in the absence of BSA, we observed a 3 log 10 -fold decrease in viral titers when samples were incubated at 60°C for 30 min, 1 log 10 -fold more than in the ambient RH conditions ( Figure 3B and Table 1 ). This also led to improved inactivation at higher temperatures, and no virus could be detected using temperatures from 75 to 95°C ( Figure 3B and Table 1 ). In the presence of BSA at 60°C for 30 min, there was a 2 log 10 -fold decrease in viral titers at 100% RH in comparison to a decrease of 1 log 10 -fold in the ambient humidity conditions ( Figure 3B ). When heated at 75°C for 30 www.acsnano.org Article D min, we observed a decrease of almost 5 log 10 -fold in viral titers, with only one of three replicates being detectable ( Figure 3B and Table 1 ). To test whether our findings are generalizable to other coronaviruses, we tested the heat sensitivity of human coronavirus NL63 (HCoV-NL63) from the genus Alphacoronavirus, subgenus Setracovirus, and another (+)ssRNA enveloped virus, CHIKV-181/25, a member of the family Togaviridae, genus Alphavirus. These viruses were also dried on meltblown fabric, using the same protocol as for SARS-CoV-2. At 60 or 75°C for 30 min in ambient RH (40% RH) HCoV-NL63 was reduced 0.5 or 1.5 log 10 -fold, respectively, whereas CHIKV-181/25 was reduced by a little over 1 log 10fold at both of these conditions ( Figure 4A and B) . At higher temperatures, the stabilities of HCoV-NL63 and CHIKV-181/ 25 were comparable, showing about 2.5 log 10 -fold reduction at 85°C for 20 min or 95°C at 5 min ( Figure 4A and B) . HCoV-NL63 and CHIKV-181/25 inactivation was done in ambient RH (40%), while SARS-CoV-2 inactivation was done in ambient RH (60%). This may explain the increased resistance of HCoV-NL63 and CHIKV-181/25 to heat inactivation compared with SARS-CoV-2. We next tested the heat stability of these viruses on meltblown fabric under 100% RH conditions, either without or with 3 g/L of BSA as a stabilizer. Under the conditions of 100% RH and without BSA, both HCoV-NL63 and CHIKV-181/25 were reduced by 2 log 10 when heated at 60°C for 30 min (Figure 4C and D) . When BSA was added, HCoV-NL63 was differentially more stabilized than CHIKV-181/25 ( Figure 4C and D) . After heating for 30 min at 60°C, CHIKV-181/25 titers were reduced by 2 log 10fold, whereas HCoV-NL63 titers were reduced by only 1 log 10fold; after heat treatment for 30 min at 75°C, CHIKV-181/25 titers were reduced by 4 log 10 -fold in comparison to a reduction of 2 log 10 -fold for HCoV-NL63 ( Figure 4C and D) . CHIKV-181/25 was not detected following either the 85 or 95°C treatments, whereas HCoV-NL63 titers were below the LOD at 85°C for 20 min but still detectable when treated with 95°C for 5 min (Figure 4C and D) . Although a direct comparison was not done with SARS-CoV-2, the reductions observed for CHIKV-181/25 were comparable with SARS-CoV-2, and these viruses were slightly more sensitive to heat inactivation than HCoV-NL63 at 100% RH ( Figure 4B , C, and D). Taken together, these results suggest that moist heat is an effective method to decontaminate FFRs from SARS-CoV-2 and other RNA viruses. CONCLUSIONS COVID-19 is an exceptionally contagious disease that requires healthcare workers to take many precautions including the use of PPE to protect themselves. The shortage of PPE caused by the COVID-19 pandemic can be mitigated by decontamination of this equipment, allowing for safe reutilization. We tested different temperatures for heat inactivation of SARS-CoV-2 dried on a piece of meltblown fabric, a key component of N95-grade FFRs, under conditions of ambient or 100% RH. We found that temperatures of 75−85°C are able to efficiently inactivate the virus in 20−30 min under 100% RH, without lowering filtration efficiency. This humidity does not extensively impact filtration, as FFRs can undergo at least 20 cycles of 75°C for 30 min/cycle or 85°C for 20 min/cycle at 100% RH without losing filtration efficiency. Although there remains uncertainty regarding whether other pathogens can be effectively inactivated by moist humidity, this is a promising decontamination method in the context of the COVID-19 pandemic. Our work also revealed that humidity has a profound effect on heat inactivation of dried SARS-CoV-2, which should be taken into consideration for public policies to prevent infection by SARS-CoV-2. To allow for development of decontamination methods based on our approach, we also tested two enveloped RNA viruses, CHIKV-181/25 and HCoV-NL63, which are risk group 2 viruses that can be handled safely in a BSL-2 lab. The temperatures and humidities used above are easily deployable or scalable in a hospital or potentially to the public. While our study dealt with meltblown fabrics, these results can potentially be applied to household fabrics as well. Because meltblown is the least robust material used in face coverings, it is plausible that using this method on spunbonded polypropylene and other household materials in homemade facial coverings would be effective in disinfection. Whereas meltblown fabrics rely on electrostatic adsorption for filtration, the household materials only rely on physically blocking particles. 32 Thus, their filtration efficiency would not be affected by these treatment conditions. In addition, as the conditions of heat and humidity in this study are relatively mild, this approach may be useful for future filtration media as well. Nanofibers, which may become more common in nextgeneration filtration media, would be expected to be stable and compatible with this disinfection scheme (given an appropriate chemical composition). This study suggests that multiple hospital or household devices (warmers, heaters, circulators, certain ovens, etc.) could potentially be used for the disinfection of respirators or other facial coverings during the current and future pandemics. Finally, it is important to note that while the filtration properties were not affected (up to 20 cycles at the aforementioned conditions), we did not evaluate the fit of respirators to determine whether changes occurred with the treatments, and while one study shows that these conditions did not affect fit, 27 donning the respirators multiple times can change the fit and can potentially expose the user to hazardous particles. 33 Air Filtration Efficiency Measurement of Meltblown Fabric. Meltblown fabric with filtration efficiency of ≥95% was procured from Guangdong Meltblown Technology Co., Ltd. It has a base weight of 20 g/m 2 . All samples were cut to approximately 15 cm × 15 cm. Filtration efficiency and pressure drop were measured on a Certitest Automated Filter Tester model 8130A (Tsi, Inc.). The flow rate for all measurements was 32 L/min, and a 2% NaCl solution was used to generate aerosol with 0.26 μm mass median diameter/0.075 μm count median diameter. Each uncertainty is determined from at least three measurements. Samples that were tested were not retested. The conditioning and aging of samples under different temperatures and humidities was performed in an SH-642 environmental chamber. The chamber can control relative humidity to a minimum of 30% for temperatures less than 85°C. Above 85°C, the relative humidity is <30% but not measured. Relative humidities of 100% were simulated by placing the meltblown fabrics into sealed plastic bags with 0.3 mL of water. For 75°C, the samples were aged for 30 min per cycle, for 85°C the samples were aged for 20 min per cycle, for 95°C the samples were aged for 15 min per cycle, for 100°C the samples were aged for 10 min per cycle, and for 125°C the samples were aged for 10 min per cycle. All SEM images were taken on a Phenom Pro SEM, with 10 kV as the electron voltage. Cells and Viruses. Vero E6 (ATCC CRL-1586) and MA-104 (ATCC CRL-2378.1) cells were maintained in Dulbecco's minimal essential media (DMEM, Gibco) and ATCC-formulated Eagle's minimum essential medium (EMEM, ATCC) supplemented with 5% fetal bovine serum (FBS, Atlanta Biologicals) and 1% penicillin/ ampicillin (Gibco). Cell cultures were maintained in an incubator set to 37°C with 5% CO 2 . SARS-CoV-2 strain USA_WA1/2020 was obtained from the World Reference Center for Emerging Viruses and Arboviruses (WRCEVA) at passage 4 (in Vero cells) and amplified in Vero E6 cells to generate a working stock. All manipulations of SARS-CoV-2 were done in a biosafety level 3 (BSL-3) lab. A confluent flask was infected with SARS-CoV-2 at an MOI of 0.001 in 5 mL of DMEM supplemented with 2% FBS, 200 mg/mL of streptomycin, and 200 U/mL of penicillin. Adsorption was allowed to proceed for 1 h in an incubator set to 37°C with 5% CO 2 , rocking every 15 min. The medium was then removed, and 20 mL of DMEM supplemented with 2% FBS and antibiotics was added. After 3 days of infection, when widespread cytopathic effect (CPE) was observed, the supernatant was collected, spun for 5 min at 3000g on a tabletop centrifuge, aliquoted, and stored at −80°C. HCoV-NL63 strain and CHIKV-181/25 vaccine strain 181/25 were obtained from the Biodefense and Emerging Infections Research Resources Repository (BEI) and amplified in Vero E6 cells. Heat Inactivation of Viruses on Meltblown Fabric. Heat tests of SARS-CoV-2 inactivation on meltblown fabric were performed in a BSL-3 lab, in either an absolute humidity of 100% or ambient with absolute humidity (60 ± 1%, as measured during the experiment), in either the absence or presence of BSA (3 g/L). Pieces of meltblown fabric were cut into 2 × 2 cm squares, and 20 droplets of 5 μL each of virus stock (8 × 10 6 PFU/mL) were dripped on top of the fabric. The virus was allowed to dry for 2 h at room temperature in the biosafety cabinet. The pieces of fabric with dried virus were then transferred to a microcentrifuge tube using sterilized forceps. For the ambient humidity experiments, the microcentrifuge tubes were empty, whereas for the 100% humidity experiments, 100 μL of autoclaved deionized water was added to the bottom of the tube (the fabric did not touch the water). Tubes were then heated at the specified temperatures using heat blocks. After heat treatment, DMEM supplemented with 2% FBS and 1% penicillin/ampicillin was added to each tube, 900 μL in the 100% humidity conditions and 1 mL in the ambient humidity conditions. The tubes were vortexed for 30 s each, and the virus was immediately titrated. Heat inactivation of HCoV_NL63 and CHIKV-181/25 on meltblown fabric was performed in a BSL-2 lab at Vitalant Research Institute as described for SARS-CoV-2 above. Plaque Assay. Vero E6 six-well plates were prepared the previous day by adding 800 000 cells per well and were then transferred to a BSL-3 before manipulating SARS-CoV-2. Samples to be titrated were serially diluted in DMEM supplemented with 2% FBS and 1% penicillin/ampicillin. From each dilution, 250 μL was added to the Vero E6 monolayer, and samples were incubated with the virus for 1 h in an incubator set to 37°C with 5% CO 2 , rocking every 15 min. After 1 h, cells were overlaid with 4 mL of a solution containing 0.8% agarose, 4% FBS, and antibiotics in minimum essential medium (MEM) without phenol red (Thermo Fisher). The plate was incubated for 2 days at 37°C with 5% CO 2 , and then 2 mL of 0.05% neutral red (Thermo Fisher) was added on top of the overlay for 6 h. Neutral red was then removed, and plaques were visualized in a biosafety cabinet using a light box and were counted. TCID50 Assay. Titers of HCoV-NL63 and CHIKV-181/25 were measured by TCID 50 using MA-104 and Vero E6 cells respectively. Viruses were serially diluted in respective medium supplemented with 2% FBS prior to addition to the cell monolayer in a 96-well plate. For each dilution, viruses were added to 10 replicate wells at 100 μL per well. The plates were incubated for 2 days (for CHIKV-181/25) or 6 days (for HCoV-NL63) at 37°C with 5% CO 2 until a clear cytopathic effect developed. Cells were stained with crystal violet, and 50% end points were calculated with the Reed and Muench method. 34 Statistical Analyses of Plaque Assays and TCID 50 Assays. To assess statistical differences in viral titers, one-way ANOVA with Sidak's multiple comparison test was used to compare each condition to the control condition (25°C for 30 min). The LOD is the theoretical lowest amount of virus that can be detected in one replicate. For Table 1 , reductions are shown as the difference between the averages of the 25°C and each temperature of the same treatment condition. Error represents pooled standard deviation of the samples treated at 25°C and the samples treated at each temperature. Virus titers below the LOD could indicate a complete inactivation of the virus or reduction of viral titers to low titers that were not able to be detected. Samples below the LOD were indicated in Table 1 as being more reduced (≤) than the difference between the 25°C condition and the LOD. The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acsnano.0c06565. Raw data measurements used for the filtration efficiency at various temperatures and humidities (PDF) Scott C. Weaver − Department of Microbiology and Immunology and Institute for Human Infections and Immunity, University of Texas Medical Branch, Galveston, Texas 77550, United States; Email: sweaver@utmb.edu Comparing SARS-CoV-2 with SARS-CoV and Influenza Pandemics Transmission of COVID-19 Virus by Droplets and Aerosols: A Critical Review on the Unresolved Dichotomy Airborne Transmission of Severe Acute Respiratory Syndrome Coronavirus-2 to Healthcare Workers: A Narrative Review Infection and Rapid Transmission of SARS-CoV-2 in Ferrets Identifying Airborne Transmission as the Dominant Route for the Spread of COVID-19 Review of Aerosol Transmission of Influenza a Virus Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs Comparison of Performance of Three Different Types of Respiratory Protection Devices Physical Distancing, Face Masks, and Eye Protection to Prevent Person-To-Person Transmission of SARS-CoV-2 and COVID-19: A Systematic Review and Meta-Analysis Do N95 Respirators Provide 95% Protection Level against Airborne Viruses, and How Adequate Are Surgical Masks? Can N95 Respirators Be Reused after Disinfection? How Many Times? A Scalable Method of Applying Heat and Humidity for Decontamination of N95 Respirators during the COVID-19 Crisis Dry Heat and Microwave-Generated Steam Protocols for the Rapid Decontamination of Respiratory Personal Protective Equipment in Response to COVID-19-Related Shortages Decontamination of Surgical Face Masks and N95 Respirators by Dry Heat Pasteurization for One Hour at 70°C. Am Decontamination and Reuse of N95 Filtering Facemask Respirators: A Systematic Review of the Literature Microwave-Generated Steam Decontamination of N95 Respirators Utilizing Universally Accessible Materials Enveloped Virus Inactivation on Personal Protective Equipment by Exposure to Ozone Development of a Highly Effective Low-Cost Vaporized Hydrogen Peroxide-Based Method for Disinfection of Personal Protective Equipment for Their Selective Reuse During Pandemics Multicycle Autoclave Decontamination of N95 Filtering Facepiece Respirators Effects of Ultraviolet Germicidal Irradiation (UVGI) on N95 Respirator Filtration Performance and Structural Integrity Impact of Three Biological Decontamination Methods on Filtering Facepiece Respirator Fit, Odor, Comfort, and Donning Ease Testing Thermal Resistance of Viruses Role of Absolute Humidity in the Inactivation of Influenza Viruses on Stainless Steel Surfaces at Elevated Temperatures Heat Inactivation of Different Types of SARS-CoV-2 Samples: What Protocols for Biosafety, Molecular Detection and Serological Diagnostics? Viruses The Effects of Temperature and Relative Humidity on the Viability of the SARS Coronavirus Is the Fit of N95 Facial Masks Effected by Disinfection? A Study of Heat and UV Disinfection Methods Using the Osha Protocol Fit Test Quantitation of Proteins in Sputum from Patients with Chronic Obstructive Lung Disease. II. Determination of Albumin, Transferrin, Alpha1-Acid Glycoprotein, IgG, IgM, Lysozyme and C3-Complement Factor Sputum Proteomic Signature of Gastro-Oesophageal Reflux in Patients with Severe Asthma Sputum Proteomics Reveals a Shift in Vitamin D-Binding Protein and Antimicrobial Protein Axis in Tuberculosis Patients. Sci. Rep. 2019, 9 Evaluation of Chemical Protocols for Inactivating SARS-CoV-2 Infectious Samples Household Materials Selection for Homemade Cloth Face Coverings and Their Filtration Efficiency Enhancement with Triboelectric Charging Impact of Multiple Consecutive Donnings on Filtering Facepiece Respirator Fit A Simple Method for Estimating Fifty Per Cent Endpoints