key: cord-1000705-gtxxznlg authors: Bodur, Süleyman; Erarpat, Sezin; Günkara, Ömer Tahir; Bakırdere, Sezgin title: Development of an easy and rapid analytical method for the extraction and preconcentration of chloroquine phosphate from human biofluids prior to GC–MS analysis date: 2021-01-24 journal: J Pharmacol Toxicol Methods DOI: 10.1016/j.vascn.2021.106949 sha: 05547e5aec7d6a615e9f98a44a1d4df497236898 doc_id: 1000705 cord_uid: gtxxznlg A vortex assisted spraying based fine droplet formation liquid phase microextraction (VA-SFDF-LPME) method was developed to determine chloroquine phosphate at trace levels in human serum, urine and saliva samples by gas chromatography–mass spectrometry (GC–MS) with single quadrupole mass analyzer. In the first part, several liquid phase microextraction (LPME) and magnetic solid phase extraction (MSPE) methods were compared to each other in order to observe their extraction ability for the analyte. VA-SFDF-LPME method was selected as an efficient and easy extraction method due to its higher extraction efficiency. Optimization studies were carried out for the parameters such as extraction solvent type, sodium hydroxide volume/concentration, sample volume, spraying number and mixing type/period. Tukey's method based on post hoc test was applied to all experimental data for the selection of optimum values. Optimum extraction parameters were found to be 12 mL initial sample volume, two sprays of dichloromethane, 0.75 mL of 60 g/kg sodium hydroxide and 15 s vortex. Under the optimum conditions, limit of detection and quantification (LOD and LOQ) were calculated as 2.8 and 9.2 μg/kg, respectively. Detection power of the GC–MS system was increased by approximately 317 folds with the developed extraction/preconcentration method. The applicability and accuracy of the proposed method was evaluated by spiking experiments and percent recovery results for human urine, serum and saliva samples were found in the range of 90.9% and 114.0% with low standard deviation values (1.9–9.4). The coronavirus disease caused by the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has spread worldwide and ruined the health system especially in developing countries (Sunkari et al., 2020) . The disease infects people by the direct contact of infected individuals, contaminated surfaces/wastes, airborne/respiratory droplets and fecaloral routes (Heller et al., 2020; Kitajima et al., 2020; Patrício Silva et al., 2021) . Up to now, millions of people have been infected by the COVID-19 disease and death toll is still on the rise (Chandra et al., 2021; COVID-19 Map -Johns Hopkins Coronavirus Resource Center, 2020) . There are several antiviral drugs to fight against COVID-19 and its symptoms. Chloroquine with its antiviral property is known as one of candidate drugs used in the treatment of the disease (Costanzo et al., 2020) . According to in vitro studies, SARS-CoV-2 was inhibited by using chloroquine chemical (Devaux et al., 2020; X. Li et al., 2020; Wang et al., 2020) . On the other hand, chloroquine has various adverse effects on human bodies such as retinal toxicity, cardiotoxicity, neurotoxicity, myotoxicity and hypokalemia (Mubagwa, 2020) . For these reasons, it is necessary to develop an analytical method for accurate and J o u r n a l P r e -p r o o f Journal Pre-proof sensitive determination of chloroquine at trace levels in biological samples to obtain comprehensive evaluation on its detrimental effects and consequences. In general, gas chromatography and liquid chromatography have been used to separate drugs and non-retained compounds from each other and equipped with proper detector for their instrumental detection (Kar, 2005) . Chloroquine has been qualified/quantified by high performance liquid chromatography-ultraviolet detection (HPLC-UV) (Cheomung & Na-Bangchang, 2011) , high performance liquid chromatography-fluorescence detection (HPLC-FL) (Samanidou et al., 2005) , gas chromatography (GC)-nitrogen sensitive detector (Churchill et al., 1983; Viala et al., 1981) , differential pulse voltammetry (DPV) (Mashhadizadeh & Akbarian, 2009) , liquid chromatography-tandem mass spectrometry (LC-MS/MS) (Boonprasert et al., 2012; Singhal et al., 2007) , laser induced fluorescence (Amador-Hernández et al., 2001) , liquid chromatography/ion trap mass spectrometry (LC-IT-MS), liquid chromatography/time of flight mass spectrometry (LC-TOF-MS) and nuclear magnetic resonance (NMR) spectroscopy (Dongre et al., 2009) . Additionally, there is no many studies in literature for the determination of chloroquine by using GC instruments. However, GC systems have higher resolution and peak capacity for complex matrices than LC systems. Moreover, GC hyphenated with MS are named as powerful measurement method for the volatile and semi-volatile compounds (McEwen & McKay, 2005) . Extraction methods are frequently used to eliminate or decrease matrix effects and preconcentrate the analyte into detectable concentrations (Marchi et al., 2009) . Several offline extraction and microextraction methods such as solid phase microextraction (SPME) (Beale et al., 2018; Kudlejova et al., 2012; Lord & Pawliszyn, 2000; Risticevic et al., 2010) , headspace solid phase microextraction (HS-SPME) (Miekisch et al., 2008) , dispersive liquid-liquid microextraction (DLLME) (Jain & Singh, 2016), magnetic solid phase extraction (MSPE) (W. kui Li & Shi, 2019) , switchable-hydrophilicity solvent liquid-liquid microextraction (SHS-J o u r n a l P r e -p r o o f Journal Pre-proof LLME) (Ahmar et al., 2018; Alshana et al., 2020; Shahvandi et al., 2018) , hollow-fiber liquidphase microextraction (HF-LPME) (de Bairros et al., 2015) , hollow-fiber with drop-to-drop solvent microextraction (HF-DDSME) (Tapadia et al., 2011) , ionic liquid-dispersive liquidliquid microextraction combined with micro-solid phase extraction (IL-DLLME-µ-SPE) (Ge & Lee, 2013), ultrasound-enhanced air-assisted liquid-liquid microextraction (USE-AALLME) (Barfi et al., 2015) and molecularly imprinted solid-phase microextraction (MISPME) (Ansari & Karimi, 2017) have been employed to extract and preconcentrate different drugs prior to their qualification/quantification with proper instruments. In DLLME method, a dispersive solvent is used to efficiently disperse the extraction solvent into the aqueous solution (Assadi et al., 2012; Przyjazny, 2019; Sajid, 2018) . However, the usage of dispersive solvent in the microextraction procedure causes to high solvent consumption and waste. For this reason, air-assisted liquid phase microextraction methods have been introduced to decrease or eliminate the dispersive solvent (Campillo et al., 2020; Farajzadeh et al., 2020) . One study published by Dikmen et al. presented spraying based fine droplet formation liquid phase microextraction (SFDF-LPME) as a rapid and simple microextraction method for the extraction and preconcentration of a pesticide without dispersive solvent (Dikmen et al., 2020) . The object of this study was to develop a sensitive analytical method for trace determination of chloroquine phosphate in human urine, saliva and serum samples. In the determination, vortex assisted spraying based fine droplet formation liquid phase microextraction prior to GC-MS system was employed to preconcentrate the analyte. Influential parameters on the VA-SFDF-LPME method was fully optimized by univariate optimization approach. After the analytical performance studies, spiking experiments were performed in human urine, serum and saliva samples in an effort to ascertain the accuracy and applicability of the proposed method. Chloroquine phosphate (99.4%) was supplied from Abdi İbrahim pharmaceutical company (İstanbul, Turkey). Dichloromethane, 1,2-dichloroethane and ammonium hydroxide were purchased from Merck (Darmstadt, Germany). Chloroform, acetonitrile and ethanol were obtained from Isolab Laborgeräte GmbH Chemicals (Eschau, Germany). Sodium hydroxide (98%) was supplied from Ak Kimya (Yalova, Turkey). Ultrapure water produced by Elga Flex 3 Water Purification System (High Wycombe, United Kingdom) was used during all sample/standard preparation and cleaning processes. An analytical balance (OHAUS PA214C) with a resolution of 0.1 mg was used throughout all sample/standard preparations. A vortex mixer supplied from IsoLab Laborgeräte GmbH (Germany) was used for all mixing purposes. A centrifuge (Hettich-EBA20) was used to achieve distinct phase separation in the developed microextraction method. Sodium hydroxide (0.75 mL, 60 g/kg) was added into 12.0 mL sample/standard solution in order to remove phosphate ion found in the analyte structure. A spray bottle containing dichloromethane as the extraction solvent was connected to the centrifuge tube by a screw cap with a center hole. Next, the centrifuge tube was overturn and the extraction solvent was sprayed into the aqueous solution two times. The sprayed aqueous solution was then vortexed for 15.0 seconds to assist the analyte mass transfer from the aqueous phase to the extraction solvent. In order to facilitate the organic phase separation, the aqueous solution was centrifuged at 3461 g for two minutes. The organic phase was transferred into a clean vial with the help of a microliter pipette and sent to the GC-MS system by an automatic liquid sampler. The repeatability of spray system was tested by gravimetric measurements. For this purpose, dichloromethane was sprayed two times with the help of spray system into three separate empty tubes. The mean value of dichloromethane sprayed was calculated as 0.281 ± 0.06 g corresponding to 211.6 ± 4.2 µL that was converted by using the density of dichloromethane. In the experiments, all standard and sample solutions were prepared by gravimetric approach that has more accuracy and precision than the volumetric one. All biological samples were obtained from volunteers in our research laboratory. Protein precipitation was applied to all samples before applying the developed microextraction method. In spiking experiments, human urine sample (2.33 g) was firstly spiked to desired concentration and alkalified by 0.95 g concentrated ammonium hydroxide. Acetonitrile (3.30 g) was added into the urine sample to precipitate protein ingredient in the sample and then diluted to 7.0 g with ultrapure water. After the protein precipitation, centrifugation process at 4420 g for 5.0 minutes was applied to the sample for the separation of supernatant phase. Following that 6.0 g of supernatant was transferred into a clean 50 mL tube and diluted to 40.0 g with ultrapure water. Human serum and saliva samples (2.33 g) were separately weighed and spiked to the desired concentration. Acetonitrile (4.20 g) as the reagent for the protein precipitation was added to the spiked sample. After diluting to 7.0 g with ultrapure water, centrifugation at 4420 g was held for 5.0 minutes. The supernatant phase (6.0 g) was completed to 40 g with ultrapure water. After performing the protein precipitation of all samples, the developed microextraction procedure given in Section 2.3 was applied to the diluted samples. In the optimization studies, all parameters were investigated in three replicates and optimum values were selected in terms of peak area, standard deviation value and statistical evaluation by post hoc comparison with analysis of variance (ANOVA). JASP 0.9.1.0 software was used throughout all statistical analyses. The statistical significance was assessed by Tukey's honestly significant differences (HSD) test with 5.0% significance. Letters (a,b,c,d) on the J o u r n a l P r e -p r o o f Journal Pre-proof figures represents significant differences according to p tukey value at 95% confidence interval. If two data were statistically similar, same letters were written to demonstrate their similarity. SFDF-LPME, DLLME and SHS-LPME methods were individually applied to 8.0 mL standard solutions (1.0 mg/kg) after adding 0.50 mL of 80 g/kg sodium hydroxide. In the DLLME method, an organic solvent mixture including 200 µL chloroform and 2.0 mL ethanol was injected into the solution. Another experiment was performed by the SHS-LPME method. 1.0 mL of protonated N,N-dimethyl benzylamine was added into the aqueous solution and then 1.0 mL of 80 g/kg sodium hydroxide was pipetted into the solution. The synthesis of protonated N,N-dimethylbenzylamine was reported in our previous study (Erarpat et al., 2019) . One standard solution was extracted by the SFDF-LPME method consisting of two sprays of chloroform implemented by the spray system detailed in Section 2.3. All solutions were subjected to vortex mixing for 15.0 s and centrifugation process for 2.0 min. The organic phases were injected into the GC-MS system. MSPE method was also tested to observe its extraction efficiency for the selected analyte. Optimization studies were performed to achieve high signal to noise ratio, low matrix effects and high preconcentration factor. For this purpose, important parameters such as type of microextraction method, type of extraction solvent, spraying number, initial sample volume, mixing type/period, concentration/volume of sodium hydroxide were meticulously investigated by univariate optimization approach. Chloroquine concentration in the optimization of microextraction method, extraction solvent, spraying number was 1.0 mg/kg while the other optimizations were performed using 0.5 mg/kg chloroquine standard solution. In this study, SFDF-LPME, DLLME and SHS-LPME methods were tried to compare their ability to preconcentrate the analyte from the aqueous solution. All experiments in Section 2.6 were done for the selected liquid phase microextraction methods. According to the results demonstrated in Figure 1 , the SFDF-LPME method is the best liquid based microextraction method among the tested ones. In addition, this method had different results according to ANOVA results at 95% confidence level. It is also clear that it had several benefits such as simplicity, cheapness, low solvent consumption and easy operability if compared to the SHS-LLME method having the second highest peak area. MSPE was also tried to test its performance on the extraction/preconcentration of the analyte. However, no detectable signal was obtained for all type of nanoparticles. This result proved J o u r n a l P r e -p r o o f Journal Pre-proof that the SFDF-LPME method was an efficient microextraction method for target analyte due to its high peak areas. First attempt to optimize the VA-SFDF-LPME method was the selection of extraction solvent. It is important to choose an ideal extraction solvent for the liquid based microextraction methods because it should have different density, water immiscibility and be capable of the preconcentration of the analyte (Psillakis & Kalogerakis, 2002) . Three halogenated solvents (chloroform, dichloromethane and 1,2-dichloroethane) were selected for this optimization. As can be seen in Figure 2 , all halogenated solvents gave different peak areas with low standard deviation values (≤ 10%). Dichloromethane was chosen as the optimum extraction solvent due to its maximum peak areas. Its experimental results were also statistically different from chloroform and 1,2-dichloroethane at 95% confidence interval. In literature, DLLME is one the most used preconcentration methods for the determination of several organic and inorganic analytes. The key point in this method is to distribute the extraction solvent through the aqueous solution with the aid of a dispersive solvent that possess miscibility in both water and organic phases (Rutkowska et al., 2019) . In spite of its high extraction efficiency and rapid equilibrium between the extraction solvent and aqueous phase, the requirement for the dispersive solvent results in competition with the extraction solvent for the analyte(s) and decreases the extraction outputs (Przyjazny, 2019) . In this study, the selected extraction solvent was introduced into the aqueous solution by the spray system. Hence, dispersion of the extraction solvent into the aqueous solution was achieved without a dispersive solvent. In this optimization, spraying number was investigated between one and three sprays (Figure 3 ) because of its effect on the preconcentration factor. According to the J o u r n a l P r e -p r o o f Journal Pre-proof integrated peak areas, the best results were obtained when two sprays were applied to the aqueous solution. There was also a gradual decrease in the peak areas resulted from the inverse relationship between the volume of extraction solvent and preconcentration factor. Therefore, two sprays were used for the subsequent experiments. Mixing is an effective way to enhance the mass transfer of the analyte from the aqueous phase to the extraction solvent. For this purpose, mechanical shaker, vortex and ultrasonication bath were examined to obtain high signal to noise ratios for the analyte. Vortex had slightly higher peak heights than other mixing types. Its repeatability was also the lowest one when standard deviation values were considered. Hence, mixing with vortex was selected as the optimum one. Further experiments were done for the selection of vortex period. The tested periods were 15, 30, 45, 60 seconds. In addition, one experiment was performed without vortex mixing to make a comparison with other periods. The optimum period was determined as 15 seconds due to its high signals, low standard deviation value and statistically significant difference from other periods. It is well known that initial volume of the sample is a critical parameter to achieve better results in the extraction of trace analytes from the aqueous samples (Soylak & Uzcan, 2020) . Three different initial volumes of chloroquine standard solution (8.0, 10.0 and 12.0 mL) were tested to increase the preconcentration factor of the analyte. As expected, the highest results were recorded for 12.0 mL of sample volume (Figure 4) which was also the maximum volume to avoid leaking from the screw cap of the centrifuge tube. Therefore, 12.0 mL was used as the initial sample volume for the further studies. In this study, sodium hydroxide was used to remove phosphate ion from the analyte since there was no signal obtained from the analyte extraction without sodium hydroxide. However, sodium hydroxide concentration and volume can positively or negatively affect the analyte extraction and purification. Several concentrations of sodium hydroxide in the range of 20 and J o u r n a l P r e -p r o o f Journal Pre-proof recorded for 20 and 40 g/kg of sodium hydroxide while 60 and 80 g/kg gave approximately 18% higher signals than the lower concentration values. Based on the peak areas, 60 g/kg was chosen as the optimum value to eliminate phosphate ions from the analyte. Sodium hydroxide volume was also adjusted to its optimum value because its higher volumes could lead to excess dilution of the sample. 12.0 mL sample solutions with different volumes of sodium hydroxide between 0.25 and 1.0 mL were individually tested to determine the optimum volume. According to the ANOVA results, all volumes had similar results at 95% confidence interval. Although 0.25 mL had the highest peak areas, 0.75 mL was chosen as the optimum one because 0.25 mL gave higher standard deviation value. A series of standard solutions containing different concentrations of the analyte was gravimetrically prepared and analyzed by the GC-MS system. The linearity of the analyte was achieved between 3.8 and 77.3 mg/kg with 0.9991 coefficient of determination value. Limit of detection and quantitation (LOD and LOQ) for the aqueous standard solution were found to be 0.9 and 2.9 mg/kg, respectively. The developed VA-SFDF-LPME-GC-MS method was also evaluated in terms of linearity, LOD and LOQ values. Under the optimum conditions, linear range, LOD and LOQ for the aqueous standard solution were calculated as 9.9-1003.9 µg/kg, 2.8 and 9.2 µg/kg, respectively. If all dilution processes in Section 2.4 is used, LOD/LOQ values for human serum, urine and saliva samples were calculated as 141.6/471.9 µg/kg, 106.6/355.4 µg/kg and 144.0/480.0 µg/kg, respectively. The analytical results are given in Table 1. J o u r n a l P r e -p r o o f respectively. However, all samples gave chromatographic signals below the detection limit. Next, the developed method was applied to the spiked samples. Percent recovery results calculated via external calibration method showed negative matrix effects on the analyte for the samples. In such cases, matrix matching calibration method can be used to compensate the matrix effects because of the similar matrices of calibration standard solutions and real samples. For this purpose, each sample was spiked at five different concentrations and calibration plots for each sample were obtained to quantify the analyte in the spiked samples. As given in Table 2 , satisfactory recovery results were obtained for human serum (90.9-107.2%), urine (93.7-114%) and saliva (97.9-102.4%) samples with repeatable signals when the matrix matching method was carried out. These results confirmed the method applicability and accuracy for the selected biological samples. Chromatograms obtained from GC-MS for the spiked samples and their blank measurements are given in Figure 5 . In this study, chloroquine was isolated and preconcentrated from the selected biological samples by using a rapid and simple VA-SFDF-LPME-GC-MS method. In addition, several LPME and MSPE methods were investigated to get low limit of detection for the analyte. After the univariate optimization studies for the proposed method, LOD/LOQ values were recorded as 2.8/9.2 µg/kg. The LOD value of conventional GC-MS system was enhanced by about 317 folds. The developed method was successfully applied to the spiked biological samples to check the method applicability and accuracy. Satisfactory recovery results for the VA-SFDF-LPME-GC-MS system were found in the range of 90. Solid-Phase Microextraction Method Development Simultaneous determination of monodesethylchloroquine, chloroquine, cycloguanil and proguanil on dried blood spots by reverse-phase liquid chromatography Recent advances and applications of carbon nanotubes based composites in magnetic solid-phase extraction Molecular immune pathogenesis and diagnosis of COVID-19 Microextraction of drugs Sample preparation development and matrix effects evaluation for multianalyte determination in urine Voltammetric determination of some antimalarial drugs using a carbon paste electrode modified with Cu(OH)2 nano-wire A combination atmospheric pressure LC/MS:GC/MS ion source: Advantages of dual AP-LC/MS:GC/MS instrumentation Assessment of propofol concentrations in human breath and blood by means of HS-SPME-GC-MS Cardiac effects and toxicity of chloroquine: a short update Increased plastic pollution due to COVID-19 pandemic: Challenges and recommendations Extraction | Liquid-phase microextraction Developments in single-drop microextraction Protocol for solidphase microextraction method development Liquid-phase microextraction: A review of reviews Dispersive liquid-liquid microextraction coupled with derivatization: A review of different modes, applications, and green aspects Simultaneous determination of quinine and chloroquine anti-malarial agents in pharmaceuticals and biological fluids by HPLC and fluorescence detection Development of a new pH assisted homogeneous liquid-liquid microextraction by a solvent with switchable hydrophilicity: Application for GC-MS determination of methamphetamine Sensitive and rapid liquid chromatography/tandem mass spectrometric assay for the quantification of chloroquine in dog plasma A novel ultrasonication-assisted deep eutectic solvent microextraction procedure for tartrazine at trace levels from environmental samples Sources and routes of