key: cord-1000695-evih162s authors: De Forni, Davide; Poddesu, Barbara; Cugia, Giulia; Gallizia, Giovanni; Licata, Massimo La; Lisziewicz, Julianna; Chafouleas, James G.; Lori, Franco title: Low ozone concentration and negative ions for rapid SARS-CoV-2 inactivation date: 2021-03-15 journal: bioRxiv DOI: 10.1101/2021.03.11.434968 sha: d90681d9ad1c62810ed26fe06207c39494afbed7 doc_id: 1000695 cord_uid: evih162s Ozone is a powerful anti-bacterial, anti-fungal and anti-viral agent, yet exposure to high levels of ozone can pose risks to human/animal health and, in the long term, corrode certain objects. In order to overcome these risks, we evaluated the potential of using a relatively short exposure of a low concentration of ozone to disinfect an indoor environment in the absence of individuals and animals. ICON3 by O3ZONO/M2L, a new disinfection device generating both ozone and negative ions, was selected to assess the potential of this strategy to inactivate different viral isolates of SARS-CoV-2. Tests under controlled laboratory conditions were performed in a system consisting of an ozone-proof airtight plastic box inside a biological safety cabinet, where suspensions of two strains of SARS-CoV-2 were exposed to ozone and negative ions and virucidal activity was measured by means of two complementary methodologies: viral replication capacity and viral titer determination. These studies revealed that low concentration ozone (average 3.18 ppm after the peak) inactivated up to >99% of SARS-CoV-2 within 20 minutes of exposure. Under controlled conditions, similar ozone exposure was recreated with ICON3 in different volume rooms (15, 30, 60 m3) where a linear relationship was observed between the room volume and the time of continuous ozone/ions flow required to reach and maintain the desired ozone levels used in the laboratory studies. These studies suggest that ICON3 may have the potential for use in the disinfection of SARS-CoV-2 in indoor environments in the absence of individuals and animals, under properly controlled and monitored safety conditions. Coronavirus Disease 19 was first identified in Wuhan (Hubei, China) in December of 2019, it has since been declared a pandemic by the World Health Organization (WHO) in March of 2020 [1, 2] . Following the initial cases in Wuhan, its pathogenic cause, Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), has swept the world by March 2021 with over 120 million total cases and over 2.5 million deaths across 221 countries, areas, or territories. While recently approved vaccines might help to contain the viral spread, disinfection of the surrounding human environment are highly desirable. Social distancing, face masks, air ventilation, hand washing, ethanol spraying and chemical disinfection has been extensively used to decrease the reproduction rate (Rt) of this virus, a key measure of how fast the virus is growing, that is the average number of people who become infected by an infectious person. Unfortunately, these measures have not been sufficient to control virus transmission. There is a growing concern that part of the problem is constituted by the virus left in the public and private rooms, including in the air and over contaminated surfaces, similar to previous SARS infections [3, 4] . Ozone (O3) is a natural gas in the air that supports life on Earth by protecting all living forms against radiation. In the troposphere near the Earth's surface, the natural concentration of ozone is about 10 ppm, whereas it is absent at the surface or at low traces after some natural events like storms, lightning strikes and swells. Ozone is a powerful anti-bacterial, anti-fungal, and anti-viral agent [5] [6] [7] [8] [9] [10] [11] [12] . It has been used for water purification and in healthcare facilities. Several ozone generators are available to emit ozone in high concentrations (e.g. up to several hundred ppm) to kill bacteria, fungi, and molds [5] [6] [7] and to inactivate viruses [8, 9] . Based on its mechanism of action, enveloped viruses, such as coronaviruses, are more sensitive to ozone than naked viruses [10] [11] [12] . The use of ozone generators to disinfect public and private rooms has been debated because of an uncertain risk-benefit balance and there is not a consensus among countries and governmental agencies regarding the ozone levels that might expose humans to risk and how ozone generators should be regulated. According to the US Environmental Protection Agency, exposure to ozone levels greater than 0.08 ppm for 8 hours or longer is unhealthy to humans. The major risks posed to human health by ozone are decrease in lung function, induction of inflammation and associated respiratory effects, including asthma and chronic obstructive pulmonary disease exacerbations [13] . In certain European countries ozone can be advertised exclusively as a sanitizer while it is presently being reviewed in Europe by the European Environmental Agency under the Biocidal Products Regulation of ECHA (European Chemicals Agency) for use as a biocide for surface disinfection [14] . Risks are not only represented by the potential harm to human/animal health but also by the potential damage to certain materials such as electric wire coating, rubber, and fabrics [15] . The benefit of ozone treatment against SARS-CoV-2 still needs to be carefully evaluated. For the disinfection of the indoor environment in the presence of individuals, exposure to continuous verylow concentration ozone was recently proposed. It was demonstrated that over 10 hours of treatment with 0.1 and 0.05 parts per million (ppm) ozone gas for 10 and 20 hours, respectively, that are the limits of permissible exposure for humans tolerated by the Japanese Society for Occupational Health and by and USA Food and Drug Administration, respectively, ozone is capable to decrease over 95% SARS-CoV-2 infectivity [16] . While the COVID-19 pandemic could potentially justify to use such a tolerated, continuous ozone exposure to protect individuals from infection, such an approach raises both safety and efficacy issues: on one hand concerns remain about the consequences of continuous ozone exposure on human health, without any reassurance that the ozone levels could be technically really kept below the threshold of toxicity; on the other hand, while it appears feasible to maintain such minimal levels of ozone in an experimental sealed room, it seems highly problematic to maintain a constant flow for a prolonged period of time in any environment where human beings are living and operating while air is continuously exchanged. To disinfect the indoor environment a short exposure to a relatively low concentration of ozone in the absence of individuals/animals could instead be considered. ICON3, manufactured by O3ZONO (https://o3zono.it/home), is a new ozonizer that generates a flow of ozone pushed upwards along a vertical duct for an appropriate diffusion in the environment from a height of two meters. It is also an ionizer, generating a flow of negative ions. ICON3 can be programmed to emit ozone at a relatively low concentration (around an average of 3 ppm) together with ions (80 million/cm 3 ). Exposure to such a low concentration of ozone for a relatively short time (approximately 20 minutes) would be expected to inactivate viruses, including SARS-CoV-2, without harming the environment and, in addition, it has been shown not to induce systemic oxidative stress in an animal model [17] . Although ions themselves are not expected to inactivate viruses, they remove ultrafine particles including aerosols of viruses from indoor air environments [18] . It is then anticipated that ion emission would add to the activity of the disinfection. Removing particles from the environment would also be beneficial, as a recent study demonstrated that exposure to fine particulate matter is associated with an increased incidence of COVID-19 [19] . Here it is demonstrated that a relatively low concentration ozone treatment (average 3 ppm after peak) with ICON3 inactivates up to >99% of SARS-CoV-2 within 20 minutes under controlled laboratory conditions inside an ozone-proof airtight plastic box under a biological safety cabinet. Moreover, similar ozone exposure parameters could be achieved under controlled conditions with the ICON3 in different sized rooms. When considering ICON3 disinfection of rooms, a strict control should be implemented, in the absence of individuals/animals and under reasonable surveillance, so that inactivation of SARS-CoV-2 can be attempted without adversely affecting the environment and human/animal health. A new disinfection device, ICON3, was tested against SARS-CoV-2. ICON3 is an ozone and negative ions generator. It is built as a vertical structure, with the ozonizer/ionizer incorporated into the base of the device and with the ozone source placed at the top of a 2 meters high rod, allowing a constant ozone flow from top to bottom (Figure 1a) . For testing in common rooms, the device was placed at one corner and the ozone was measured by means of a detector at different distances from the generator (see Materials and Methods). For testing against SARS-CoV-2 in laboratory conditions, the rod was removed and the device was placed inside an ozone-proof airtight plastic box (dimensions 57.3x39x25.7 cm; volume: 0.057 m 3 ) inside a biological safety cabinet (Figure 1b, c) . 0.5 µL drops of SARS-CoV-2 (2019-Nov/Italy-INMI1) suspension were deposited in a 96-well plate 15 cm away from the device. An ozone detector, i.e. a Pump Type Gas Detector, was positioned next to the plate. The ozone concentration in the plastic box was maintained among experiments between 5.44 and 1.47 ppm (mean 3.18 ± 1.5 ppm after peak) for 20 minutes after supplying a flow of ozone for approximately 1 second. Similar virus suspensions were exposed to air as control, then they were all collected to measure the replicative capacity of the virus (expressed as percentage of viral nucleoprotein, representing the replicating virus, compared to the control) in a Vero E6 cell line (see Methods). Exposure to ozone under these conditions inactivated SARS-CoV-2 by >99% ( Table 1) . The experiment was repeated using a different readout, namely viral titer as opposed to a percentage of the active virus (see Materials and Methods). The results confirmed that SARS-CoV-2 (2019-nCov/Italy-INMI1 isolate) was inactivated by >99%. The experiment was performed with a different viral isolate (UNIBS-AP66: ERR4145453) that was also inactivated by >90% ( Table 2 ). These results demonstrate that a low concentration of ozone can quickly and effectively inactivate different coronavirus isolates. Since droplets and aerosol of SARS-CoV-2 found in the air and surfaces that are responsible for transmission are quite small in size [20] , it was investigated whether the size of the drops in which SARS-CoV-2 was resuspended would affect the results of the ozone treatment. During preliminary experiments it was determined that the smallest testable drop-size was 0.5 µL because smaller droplets quickly dried in the plate under the biological safety cabinet. 0.5 µL droplets are still considerably larger (by several logs) than the natural droplets originating during breathing, coughing, or sneezing [20] . conditions SARS-CoV-2 was partially inactivated even when it was contained in very large droplets (Figure 2) . Decreasing the droplet size further increased viral inactivation suggesting that SARS-CoV-2 contained in much smaller droplets originating from human coughing, sneezing or breathing might be completely inactivated. The results suggest that a relatively short exposure to the relatively low concentration of ozone generated by the ICON3 device under these controlled laboratory conditions might have the potential to disinfect the air and surfaces contaminated with SARS-CoV-2 naturally produced droplets. After demonstrating that a 20-minute exposure with a 3.18 ppm mean concentration of ozone can inactivate SARS-CoV-2 in the laboratory plastic box, it was investigated whether ICON3 could reproduce a similar ozone exposure in the most frequent sizes of an indoor environment, i.e. in three separate rooms of 15 m 3 , 30 m 3 , and 60 m 3 . In order to maintain similar ozone exposure conditions, the time for the device to remain ON (that is providing a continuous flow) had to be adapted according to the environment volume: only 1 second device ON time was needed in the laboratory cabinet (0.057 m 3 ) while it was calculated that 4.5, 9, and 18 minutes would be required for the 15 m 3 (2x2.5x3 m), 30 (3x3.3x3 m) m 3 , and 60 (4x5x3 m) m 3 rooms, respectively. Under these precisely controlled conditions, exposure levels similar to that obtained in the laboratory plastic box were achieved in all three rooms (Figure 3 a, b, c, d) . The Area Under the Curve (AUC), either Total, or Over Average or Under Average was in fact similar in all experimental conditions (Figure 3 e) . The ozone decay time (time between switching off the ICON3 device and time to reach undetectable ozone levels) was also comparable, that is less than 45 minutes in each environment, more precisely 40, 37, 38 and 43 minutes in the laboratory cabinet, 15 m 3 , 30 m 3 , and 60 m 3 rooms, respectively (Figure 3 e) . There was a linear relationship between the environment (room) volume and the time of continuous ICON3 flow required to obtain the desired ozone exposure (Figure 3 e, f) . For example, doubling the room volume required a doubling in the time during which the ICON3 device remained switched ON in order to achieve the same overall ozone exposure to the one achieved in the laboratory cabinet. Disinfection of indoor air environments, such as typical office or residential rooms, remains one of the main challenges in limiting transmission of viruses [21] . Currently these areas are disinfected by manual cleaning followed by chemical disinfection and/or ventilation. Disinfection is usually performed with alcohol-based or chlorinated solutions with or without ammonia. The safety of the person using these chemicals is essential. Cleaners must be trained to (i) wear adequate personal protective equipment such as gloves, medical masks, eye protection, and (ii) avoid combining disinfectants that could release gases causing respiratory irritations. One of the main limitations of chemicals is that the efficiency of virus inactivation in the air and surfaces is somewhat problematic and it depends on human factors. For example, 1000 ppm hypochlorite could inactivate the vast majority of pathogens according to WHO [22] , but several surfaces including furniture, mobile phones, computers, and other electronic devices, would be damaged by repeated spraying and infectious droplets would remain on these surfaces and mediate virus transmission. More importantly, cleaners use different chemicals, equipment, procedures, and their performances are not comparable nor reproducible. High concentrations (over 350 ppm) of ozone are used to inactivate SARS-CoV-2 in healthcare facilities, however, such high ozone concentrations are not commonly used in public offices and households because of safety concerns. To overcome the limitations of chemical disinfection and high concentration of ozone the ICON3 device was calibrated to emit low concentration ozone and ions to effectively and reproducibly inactivate SARS-CoV-2. Although ions produced by the ICON3 are not expected to directly inactivate SARS-CoV-2 they might contribute to precipitate virus-containing droplets and decrease the levels of small particles that are associated with increased transmission of COVID-19 [19] . The objective of this study was to keep the ozone concentration around 3 ppm for a relatively short time (i.e., 20 minutes), conditions expected to not damage the surrounding material and be applicable for use in the absence of humans/animals [15] . Under such controlled conditions up to >99% SARS-CoV-2 was inactivated in a plastic box under a biological safety cabinet in the laboratory. It was demonstrated that similar ozone exposure parameters could be achieved in several different sized rooms where the time to reach the desired ozone concentration in a given room was linearly correlated to the room volume, i.e., doubling the volume of the room required a doubling of the time of continuous ozone/ions flow. Ozone decay time was similar and independent of the environment volume. Disinfection by the ICON3 device offers distinctive features compared to other currently used methods: (i) experimental evidence has been provided here that ozone and ions emitted by the ICON3 device inactivate different SARS-CoV-2 strains up to >99% under controlled conditions; (ii) ozone is expected to penetrate everywhere and to inactivate viruses not only on selected surfaces that a cleaner disinfects but on all the surfaces present in the room as well as in the air; (iii) under the controlled conditions of this study a linear relationship between time of device ON and room volume provides a means to program the device to achieve the ozone exposure parameters obtained in the laboratory box study; (iv) since ozone quickly degrades to oxygen, after the appropriate ozone decay time, individuals returning to the ozone disinfected rooms would not be harmed; (v) furniture and equipment in the room should not be damaged; (vi) ozone would not contaminate the environment with chemical waste. [24, 25] . Ozone virucidal effects are linked to its ability to break apart lipid molecules with multiple bonds, in fact, enveloped viruses are usually more sensitive to physical-chemical challenges than naked ones. Ozone can also interact with proteins, carbohydrates, and nucleic acids [26] [27] [28] . The ozone virucidal effect is therefore largely independent from the genome of SARS-CoV-2 and is expected to be effective against multiple existing and newly emerging variants. Consistent with this expectation, we and others [16] were able to achieve inactivation of three different SARS-CoV-2 variants to a similar extent (over 90%). In this study, SARS-CoV-2 was inactivated to a large extent and in a relatively short time by using ICON3 under controlled laboratory conditions. This new ozone and ion emitting device, developed for use in public rooms and common living areas, may have the potential for use in the disinfection of SARS-CoV-2 in indoor environments in the absence of individuals and animals, under properly controlled and monitored safety conditions. Human 2019-nCoV strain 2019-nCoV/Italy-INMI1 was isolated in Italy (ex-China) from a sample collected on January 29, 2020, from the Istituto Lazzaro Spallanzani, Rome, Italy. A second strain, namely SARS-CoV-2-UNIBS-AP66: ERR4145453 [29, 30] was obtained from the University of Brescia, Italy. ICON3 is an ozonizer/ionizer manufactured by O3ZONO. Technical characteristics are illustrated in the O3ZONO website [31]. Indicated volumes of SARS-CoV-2 suspensions were exposed to ozone and negative ions produced by the ICON3 device. The treatment process was conducted inside a plastic box (dimensions 57.3x39x25.7 cm; volume: 0.057 m 3 ), where the ICON3 machine was placed, together with the viral suspension in a 96-well plate. The box was maintained under a biosafety cabinet for safety reasons. Quantity of ozone was monitored during treatment with a Pump Type Gas Detector (detection range 0-50 ppm, resolution 0.01 ppm). The device was turned on for 1 second allowing ozone to reach a maximum peak of 5.44 ppm. Contact time was 20 minutes. The test temperature was 21°C ± 1°C. Relative humidity in the cabinet was 50 ± 1%. An identical volume of viral suspension exposed to the air for the same contact time was used as control. The replicative capacity of treated viral suspensions was measured in a cell model. Vero E6 cells (kidney epithelial cells from African green monkey, ATCC CRL-1586) were maintained at their optimal density based on the ATCC datasheet. On Day 1 of the experiment, cells were transferred in a 96-well plate (10.000 cells per well). On Day 2 cells were infected with the different viral suspensions (treated and not treated with ozone and negative ions) in quadruplicate wells at a multiplicity of infection (m.o.i.) of 0.01. After 3 additional days, supernatants were collected, and an ELISA assay (SARS-CoV-2 Nucleocapsid Detection ELISA Kit, Sino Biological) was performed to measure produced virus through the quantification of the viral NP nucleoprotein (a measure of viral replication capacity). An in vitro system was employed to determine the viral titer of both SARS-CoV-2 treated with ozone and negative ions as well as of SARS-CoV-2 exposed to air. Vero E6 cells (kidney epithelial cells from African green monkey, ATCC CRL-1586) were maintained at their optimal density based on the ATCC datasheet. On Day 1 of the experiment, cells were transferred in a 96-well plate (10.000 cells per well). On Day 2 cells were infected with the serial viral dilutions (10 -2 , 10 -3 , 10 -4 ...) in 6-well replicates for each condition. After 3 additional days, supernatants were collected and an ELISA assay (SARS-CoV-2 Nucleocapsid Detection ELISA Kit, Sino Biological) was performed to determine infection or not of each test well, through the detection of the viral NP nucleoprotein. Data were then used to determine the titer of treated and control virus according to Reed and Muench method. Quantity of ozone was monitored with a Pump Type Gas Detector in three separate rooms of 15 m 3 , 30 m 3 , and 60 m 3 and the detector was positioned at 1, 2 and 3 meters distance from the ozone/ions generator, respectively, and at 120 cm height. The measurements were repeated two times within the same room and presented as Average and Standard Deviation at each time point. For testing against SARS-CoV-2 in laboratory conditions, the rod was removed and the device was placed inside an ozone-proof airtight plastic box (dimensions 57.3x39x25.7 cm; volume: 0.057 m 3 ) inside a biological safety cabinet. The ozone decay time was calculated in similar, separate experiments comparing the three different rooms and the plastic box under the biological safety cabinet. WHO Director-General's opening remarks at the media briefing on COVID-19 CDC Centers for Diseases Control and Prevention. COVID Data Tracker Transmission of SARS-CoV-2: implications for infection prevention precautions. Scientific brief Role of fomites in SARS transmission during the largest hospital outbreak in Hong Kong Surface germicidal effects of ozone for microorganisms Development of a Practical Method for Using Ozone Gas as a Virus Decontaminating Agent Application of ozone for enhancing the microbiological safety and quality of foods: a review Efficacy of ozone to reduce microbial populations in date fruits Inactivation of surface viruses by gaseous ozone Ozone Gas: Scientific Justification and Practical Guidelines for Improvised Disinfection using Consumer-Grade Ozone Generators and Plastic Storage Boxes Fomite transmission and disinfection strategies for SARS-CoV-2 and related viruses Ozone: a powerful weapon to combat the COVID-19 outbreak. China.org.cn, Editor's Pick United States Environmental Protection Agency. Eight-Hour Average ozone Concentrations Interim recommendations on cleaning and disinfection of non-healthcare settings during COVID-19 health emergency: surfaces, indoor environments and clothing. Version of May 15, 2020. ISS COVID-19 Working Group on Biocides 2020, 28 p Air Quality Criteria For Ozone and Related Photochemical Oxidants Reduction of severe acute respiratory syndrome coronavirus-2 infectivity by admissible concentration of ozone gas and water Ozone exposure effect on systemic prostaglandin F2α in rat plasma and urine may not reveal pulmonary damage through inflammation Removal of fine and ultrafine particles from indoor air environments by the unipolar ion emission Associations between COVID-19 Incidence Rates and the Exposure to PM2.5 and NO2: A Nationwide Observational Study in Italy Particle sizes of infectious aerosols: implications for infection control Coronavirus is in the air -there's too much focus on surfaces Cleaning and disinfection of environmental surfaces in the context of COVID-19 Centers for Disease Control and Prevention. Science Brief: Emerging SARS-CoV-2 Variants Escape from neutralizing antibodies by SARS-CoV-2 spike protein variants Spike E484K mutation in the first SARS-CoV-2 reinfection case confirmed in Brazil Inactivation of Influenza virus by ozone gas In Vitro Inactivation of Herpes Virus by Ozone Ozone for inactivation of aerosolized bacteriophages A persistently replicating SARS-CoV-2 variant derived from an asymptomatic individual Methotrexate inhibits SARS-CoV-2 virus replication "in vitro This publication was supported by the European Virus Archive GLOBAL (EVA-GLOBAL) project that has received funding from the European Union's Horizon 2020 research and innovation program under grant agreement No 87102.We thank Arnaldo Caruso and Francesca Caccuri, from the Microbiology and Virology Section, Molecular Medicine Department, University of Brescia, Italy for providing viral strain SARS-CoV-2-UNIBS-AP66: ERR4145453. We also thank Sjlva Petrocchi for editorial assistance.We also thank Sjlva Petrocchi for her comments and revisions. ViroStatics is consultant for M2L (originator of ICON3 device).