key: cord-0995957-eim3jtz6 authors: Wilkinson, Mark C.; Carney, Jennifer title: Investigating Viral Inoculation and Recovery from Medical Masks date: 2022-02-21 journal: Adv Virol DOI: 10.1155/2022/3173883 sha: 480f8e1ce0d1051626c49ecb3c4ae88f71e3f778 doc_id: 995957 cord_uid: eim3jtz6 The SARS-CoV-2 pandemic from 2019 onwards has significantly increased the usage of surgical style medical masks, both in healthcare and public settings. It is important to study the contamination of and viral transfer from such masks. However, accepted standard test methods such as ISO 18184 have prescribed inoculation methods which may not be fully representative of the type of viral insult experienced in the clinic or community. In addition to studying a conventional mask, the performance of a mask featuring an antimicrobial photosensitiser was also studied. Recently, the SARS-CoV-2 pandemic has significantly increased the usage of surgical style masks, both in healthcare and public settings. Not only has their use proliferated but also the typical duration of wear has increased significantly. Widespread use by nonhealthcare professionals has also eroded best practice regarding touching of contaminated masks and potential reuse of masks. is scenario raises several questions that could be addressed via laboratory experimentation. However, accepted methods for the study of viral contamination of fabrics-such as ISO 18184-describe standard microbiological techniques which may not best represent the presentation of viruses or the use of such masks in the clinic or community. Duration of mask wearing has increased, so repeat inoculation over extended time periods was studied. Standard methods such as ISO 18184 require direct inoculation with pipetted drops of viral suspension. However, in the real world, virus is spread as fine droplet suspensions or aerosols. To better represent this, we challenged a mask with an aerosolised inoculum. Medical (or surgical) masks typified by the type I/II/IIR classification in Europe are constructed from multiple layers of nonwoven fabric-normally between 3 and 5 layers-bonded together. Previous work has found a buildup of respiratory viruses on the outer layer of surgical type masks [1] . Indeed, the consensus standard for such devices EN 14683 : 2019 regards the mask outers as "highly contaminated" after use. SARS-CoV-2, in particular, has been shown to survive well on surgical masks, being still detectable 7 days after exposure [2] . us, the transfer of virus from contaminated masks was studied. In addition, the performance of an antimicrobial photosensitiser which has found success in other medical devices was studied here in an antiviral mask. In experiments designed to determine antiviral efficacy of the Protect Antiviral Type IIR mask, the same mask was used as control with the antiviral outer layer removed, with the exception of the aerosol study where a standard mask was used as a control. Aerosol. An Intranasal Mucosal Atomization Device (IMAD) was used to deliver 300 µl of a viral inoculum in aerosol form. e device was the MAD Nasal ™ supplied by Teleflex, fitted to a 1 ml syringe. e MAD Nasal ™ is stated by the manufacturer to deliver a fine mist of particles 30-100 microns in size. During the aerosol study, a total of 300 µl inoculum was applied to the mask over a period of 3 hours (applied hourly after the initial inoculation, exposed to approx. 1000 lux). Following the final inoculation, the mask was held for 1 hour before being transferred to 20 ml of neutraliser (recipe as per ISO 18184; 17 g/l casein peptone, 3 g/l soybean peptone, 5 g/l sodium chloride, 2.5 g/l dipotassium hydrogen phosphate, 2.5 g/l D-glucose, 1 g/l lecithin, and 7 g/l Tween 80). Any remaining viable virus was recovered by vortexing for 5 × 5 seconds and quantified. In the repeated inoculation study, 300 µl of inoculum was applied over a period of 8 hours (75 µl applied at time zero and then 75 µl applied every 2 hours, exposed to approx. 1000 lux). Following the final inoculation, the mask was held for 2 hours before being transferred to 20 ml of neutraliser. Any remaining viable virus was recovered by vortexing for 5 × 5 seconds and quantified. To demonstrate the potential to reduce transfer of viable virus from contaminated mask surfaces, approx. 4 cm × 4 cm samples of Protect Antiviral Type IIR mask and control mask were inoculated dropwise, distributing multiple (ca. 18) drops evenly across the surface of the sample, to a final volume of 200 µl of virus. After 1 hour incubation at 25°C (exposed to approx. 1000 lux), 5 pieces of nitrile glove (approx. 2 cm × 2 cm) were pressed on to the mask sample, each in a different area to ensure that the entire mask surface had been touched at least once and transferred to 10 ml EMEM. Any viable virus that had been transferred to the glove was recovered by vortexing for 5 × 5 seconds and quantified. e gloves used were Pulse ® Nitrile, manufactured by Innovative Healthcare Corporation. To ensure a consistent surface, the gloves were washed with water before use and allowed to dry. Quantification. Viral titres and viral reductions were determined by TCID 50 assays. MRC-5 cells were seeded into 96 well plates (1 × 10 4 cells/well) 1-2 days before the assay. Ten-fold serial dilutions of sample were prepared in serum-free EMEM, and each dilution was inoculated into 8 wells of a 96-well plate (100 µl/well). Plates were incubated for 1-2 hours at 33°C in 5% CO 2 . Following incubation for all assays except antiviral efficacy testing, 100 µl of serum free media was added to the wells. For antiviral efficacy testing, following incubation, inoculum was removed and wells were washed with 100 µl of serum-free EMEM before being replaced with 200 µl serum-free EMEM. Plates were incubated at 33°C in 5% CO 2 for 7 days. TCID 50 titres were determined by the Behrens and Karber method as detailed in ISO 18184 [3] . Masks were inoculated with 300 µl of a 1.00 × 10 7 TCID 50 /ml inoculum of HCoV-229E, thus 3.00 × 10 6 TCID 50 /mask. A >3 log reduction (99.97%) was observed from the AV mask at 4 hours compared to the control at T � 0 (as per ISO 18184). Masks were inoculated with 200 µl of a 3.16 × 10 7 TCID 50 /ml inoculum of HCoV-229E, thus 6.32 × 10 6 TCID 50 /mask. e results are reported "per glove" as the virus is recovered from a glove, after transfer from the mask. A visual representation of the above results is presented in Figure 1 . Our initial experiments used standard techniques as described in ISO 18184. We used this precedented method to validate simple inoculation and recovery of human coronavirus 229E from medical facemasks. A recovery greater than 87% of the initial inoculum was demonstrated immediately following inoculation of the control mask confirming suitability of the test method (Table 1) . To potentially mitigate infectious viral contamination, the utility of an antimicrobial photosensitiser was studied. A cationic zinc phthalocyanine which has previously shown good activity in antimicrobial gloves was chosen [4] . is molecule is from a class of photosensitisers known to transfer visible light energy to atmospheric oxygen, yielding the short-lived activated singlet oxygen. Singlet oxygen is known to be a potent antimicrobial agent, with excellent activity against enveloped viruses such as SARS-CoV-2 and HCoV-229E [5, 6] . In addition, the cationic nature of this photosensitiser gave it good affinity for the nonwoven cellulose layer of the mask under study. is excellent affinity was demonstrated when the mask was extracted with water for 72 hours at 37°C as per ISO 10993-12, and no photosensitiser was detected by UV/Vis spectroscopy of the extract (to the limit of detection). is bound, nonleaching presentation of the photosensitiser reduces risk to the wearer. In addition, due to the short half life and diffusion range of singlet oxygen, any biocidal activity of the mask is expressed at the surface only and not in the wider environment. During incubation, the test and control masks were illuminated with ca. 1000 lux of white LED light. is light intensity was taken from standard EN 12464-1 as the recommended intensity for medical examination. When this antiviral mask (the protect antiviral type IIR mask) was investigated using a typical ISO 18184 protocol, a >99.9% reduction in HCoV-229E was recorded at 1 hour (Table 1 ). It is possible that a significantly greater log reduction had been achieved, but due to cytotoxicity caused by the neutraliser, CPE was observed in the neat wells for all samples. It was not possible to distinguish any viral CPE from neutraliser induced CPE; therefore, these wells had to be recorded as positive, limiting the calculated log reduction values. No CPE and thus no virus were detectable in any wells beyond the neat sample for all antiviral mask samples. As an established laboratory virology test method for textiles, ISO 18184 offered a credible starting point for our studies. However, this method requires only a single inoculation. With pandemic conditions, bringing mask wearers more commonly into contact with viral challenge, it was desirable to study the impact of repeat inoculations. A control mask was inoculated with 75 µl of HCoV-229E inoculum every 2 hours for 8 hours. e suitability of the recovery method and the ability of the virus to survive under the test conditions were demonstrated ( Table 2) . When the repeat inoculum study was performed on the mask featuring an outer cellulose layer treated with the antiviral photosensitiser, a significant 99.99% reduction in virus was recorded at the end of the 8 hour study. is demonstrated the ability of the mask to continue to respond to viral insult throughout its duration of wear by maintaining antiviral activity. A comparison between these data and our other results is represented in Figure 1 We felt there were limitations to the inoculation method according to ISO 18184, which uses large aliquots pipetted on to test articles. Person to person viral spread is more typically in the form of fine droplet suspensions or aerosols. We identified the potential utility of an intranasal mucosal atomization device to deliver aerosolised inoculum. e Teleflex MAD Nasal ™ was used, which is stated by the manufacturer to deliver a fine mist of droplets in the range of 30 to 100 microns. is device has been used to more realistically mimic viral challenge in animal models, including SARS-CoV-2 [7, 8] . e protocol was validated by inoculating a standard mask hourly for 4 hours, using the IMAD. e total volume of the starting inoculum (300 µl of 1.00 × 10 7 TCID 50 /ml HCoV-229E) was delivered to the mask in this period. e viral recovery from the mask at the end of the experiment was 2.34 × 10 6 TCID 50 /mask (Table 3) . us, the validity of the inoculation pathway and recovery was demonstrated. Next, we studied the performance of the antiviral mask using the aerosol inoculation method. After application of an aerosol inoculum to masks featuring an outer cellulose layer treated with the antiviral photosensitiser, a 99.97% reduction of HCoV-229E was observed (Table 3) . us, the delivery of a more representative inoculation still showed a significant antiviral effect. In addition to considering inoculation-how virus is placed on a mask-we also evaluated cross contamination-how virus may subsequently spread from a contaminated mask surface. Medical masks should not be touched during wear, and prescribed removal procedures should be followed. In reality, best practice is not always rigorously adhered to. is problem has become compounded during the coronavirus pandemic since duration of wear has significantly increased for both professional and public use. Touching the outside of the mask to adjust fit and tightening a nose band or to eat and drink are all plausible scenarios where this can occur. With the risk for touching of masks during use established, we considered what hazard might result. e consensus standard for such medical masks EN 14683 : 2019 details that postuse masks should be considered "highly contaminated." As previously stated, it has been shown that respiratory viruses concentrate on masks during use [1] . It has also been shown that, during routine removal, viral contamination can be efficiently transferred from PPE (including masks) to the wearer's skin or clothing [9] . To mimic the use of masks by healthcare professionals, we studied viral transfer from masks to medical examination gloves. Cross contamination of pathogens from surfaces via gloves has been studied previously, and we adopted these principals in our work [10] . e viability of the protocol to efficiently transfer virus was demonstrated with 1.56 × 10 5 TCID 50 /glove being transferred from an inoculated control mask, after 1 h of incubation. In contrast, when the same transfer study was performed with the mask featuring the photosensitiser, no viable virus was detected in the assay (Table 4) . us, the potential positive impact of the antimicrobial photosensitiser to prevent cross contamination from masks was demonstrated. In conclusion, the inoculation of surgical style medical masks has been investigated, deploying techniques more representative of real mask use than established lab protocols. Successful recovery of virus has been demonstrated, validating the protocols. In addition, the utility of an antimicrobial photosensitiser to deactivate virus on the mask outer has been established. is could have a potential positive impact in reducing viral cross contamination from such masks. e data used to support the findings of this study are available from the lead author (MW) upon request. e authors declare that they have no conflicts of interest. Table 4 : Viral recovery from medical examination gloves, which had been used to transfer virus from the surface of a standard ("control") type IIR mask or a photosensitizer-treated antiviral (AV) type IIR mask. Replicate TCID 50 /glove Average TCID 50 /glove % reduction of antiviral mask SD Significance Contamination by respiratory viruses on outer surface of medical masks used by hospital healthcare workers Stability of SARS-CoV-2 in different environmental conditions International Organization of Standardization ISO 18184, Textiles -Determination of Antiviral Activity of Textile Products Antimicrobial and anticancer cationic phthalocyanine compounds Inactivation of enveloped viruses by singlet oxygen thermally generated from a polymeric naphthalene derivative Virus transfer from personal protective equipment to healthcare employees' skin and clothing Intranasal exposure of African green monkeys to SARS-CoV-2 results in acute phase pneumonia with shedding and lung injury still present in the early convalescence phase Distribution of droplets and immune responses after aerosol and intranasal delivery of influenza virus to the respiratory tract of pigs An effective inactivant based on singlet oxygen-mediated lipid oxidation implicates a new paradigm for broad-spectrum antivirals Effect of poly-hexamethylene biguanide hydrochloride (PHMB) treated non-sterile medical gloves upon the transmission of Streptococcus pyogenes, carbapenem-resistant E. coli, MRSA and Klebsiella pneumoniae from contact surfaces Paul Wight (Chemical Intelligence Limited, UK) is acknowledged for important discussion on experimental protocol. All experiments were performed by JC. Experiments were conceived and designed jointly by MCW and JC.