key: cord-0993547-93zx857p authors: Bal, Antonin; Brengel-Pesce, Karen; Gaymard, Alexandre; Quéromès, Grégory; Guibert, Nicolas; Frobert, Emile; Bouscambert, Maude; Trabaud, Mary-Anne; Allantaz-Frager, Florence; Oriol, Guy; Cheynet, Valérie; d’Aubarede, Constance; Massardier-Pilonchery, Amélie; Buisson, Marlyse; Lupo, Julien; Pozzetto, Bruno; Poignard, Pascal; Lina, Bruno; Fassier, Jean-Baptiste; Morfin, Florence; Trouillet-Assant, Sophie title: Clinical and laboratory characteristics of symptomatic healthcare workers with suspected COVID-19: a prospective cohort study date: 2021-07-22 journal: Sci Rep DOI: 10.1038/s41598-021-93828-y sha: 284f5c69c208e7fec0893878b9afb5d5fc46abe5 doc_id: 993547 cord_uid: 93zx857p A comprehensive clinical and microbiological assessments of COVID-19 in front-line healthcare workers (HCWs) is needed. Between April 10th and May 28th, 2020, 319 HCWs with acute illness were reviewed. In addition to SARS-CoV-2 RT-PCR screening, a multiplex molecular panel was used for testing other respiratory pathogens. For SARS-CoV-2 positive HCWs, the normalized viral load, viral culture, and virus neutralization assays were performed weekly. For SARS-CoV-2 negative HCWs, SARS-CoV-2 serological testing was performed one month after inclusion. Among the 319 HCWs included, 67 (21.0%) were tested positive for SARS-CoV-2; 65/67 (97.0%) developed mild form of COVID-19. Other respiratory pathogens were found in 6/66 (9.1%) SARS-CoV-2 positive and 47/241 (19.5%) SARS-Cov-2 negative HCWs (p = 0.07). The proportion of HCWs with a viral load > 5.0 log(10) cp/mL (Ct value < 25) was less than 15% at 8 days after symptom onset; 12% of HCWs were positive after 40 days (Ct > 37). More than 90% of cultivable virus had a viral load > 4.5 log(10) cp/mL (Ct < 26) and were collected within 10 days after symptom onset. Among negative HCWs, 6/190 (3.2%) seroconverted. Our data suggest that the determination of viral load can be used for appreciating the infectiousness of infected HCWs. These data could be helpful for facilitating their return to work. April 10th and May 28th, 2020, a total of 319 symptomatic HCWs were included (Fig. 1) . The main symptoms reported at inclusion were asthenia (260/317, 82%) andheadaches (252/319, 79%). Among the 319 HCWs, 67 (21.0%) were tested positive for SARS-CoV-2. The median [IQR] time between SARS-CoV-2 screening and symptom onset was 3 [2] [3] [4] [5] [6] for positive and 5 [3] [4] [5] [6] [7] [8] days for negative HCWs (p = 0.09). The median age was 36 years old for both positive and negative SARS-CoV-2 HCWs (p = 0.93). The sex ratio (M/F) was 1:6 for positive and 1:4 negative participants (p = 0.64). The proportion of active smokers was lower among positive SARS-CoV-2 HCWs (6/67, 8.9%) compared to negative SARS-CoV-2 HCWs (64/252, 25.4%; p-adjusted = 0.09). The proportion of smell and taste dysfunction was significantly higher in positive participants (26/67, 38 .8% for smell and 25/67, 37.3% for taste) than in negative participants (24/250, 9 .5% for smell, p < 0.001, and 27/250, 10 .7% for taste, p < 0.001). Diarrhea was reported in 16/67 (23.9%) positive cases and in 104/252 (41.3%) negative cases (p = 0.09). Among the 67 positive HCWs, only two severe forms required conventional hospitalization (Table 1) , and one of them required ventilation support. No ICU admission was needed. To explore the potential presence of other respiratory infections in symptomatic HCWs tested negative for SARS-CoV-2 and to assess the co-infection rate in COVID-19 HCWs, a multiplex molecular respiratory panel testing was performed. The detection of SARS-CoV-2 with the multiplex panel was fully concordant with the initial routine diagnosis. Other respiratory pathogens were found in 6/66 (9.1%) SARS-CoV-2 positive and 47/241 (19.5%) SARS-Cov-2 negative HCWs (p = 0.07). The pathogens responsible for co-infection in the 6 COVID-19 HCWs were rhinovirus/enterovirus (n = 3), adenovirus (n = 2), and parainfluenza virus 2 (n = 2); one patient was tested positive for adenovirus and rhinovirus/enterovirus) ( Table 2 ). The clinical and demographical characteristics of these 6 co-infected patients are detailed in Supplementary Table 1 . No bacterial co-infection was found for positive SARS-CoV-2 patients. For negative SARS-CoV-2 HCWs, the most frequent pathogens were rhinovirus/enterovirus (n = 27), adenovirus (n = 15), and other coronaviruses (HKU1 or NL63, n = 7). Chlamydia pneumoniae (n = 2) and Mycoplasma pneumoniae (n = 1) were also found in negative SARS-CoV-2 HCWs (Table 2) . (Fig. 2) . The percentage of HCWs with a viral load > 5 log 10 cp/mL, corresponding to a cycle threshold (Ct) value < 25, rapidly decreased during the first days after symptom onset and reached less than 15% at 8 days. At 20 days after symptom onset, about 40% of HCWs had a positive RT-PCR with a viral load > 2 log 10 cp/mL. At 40 days post-symptom onset, SARS-CoV-2 RNA was still detectable for 12% of HCWs (< 1 log 10 cp/mL, Ct value > 37). Viral culture results according to the viral load and date of symptom onset. A total of 64 SARS-CoV-2 RT-PCR positive NPS samples collected from 40 patients without co-infection were inoculated for cell Further than twelve days after symptom onset, infectious virus could be retrieved in 3 samples, only after subculture. The positivity of these subcultures was established using an RT-PCR test performed on culture supernatant as the Ct difference was > 10 compared to the first passage despite the absence of cytophatic effect (CPE). These 3 samples had a viral load ranging from 3.85 to 4.20 log 10 cp/mL and were collected from 2 patients (at 15 days after symptom onset for one patient who presented a severe form, and at 16 and 21 days after symptom onset for the other patient who presented a mild form of the disease). Neutralizing antibody (nAb) titers were measured in contemporaneous serum samples using a SARS-CoV-2 pseudo-typed virus assay. Among individuals with negative viral culture, 18/22 were positive for serum neutralizing activity, suggesting that nAbs may inhibit viral culture from respiratory samples. Of note, 6/7 individuals with a high viral load in NPS (> 4.5 log 10 cp/mL) and negative viral culture were positive for the detection of nAb. Conversely, high nAb titers were found in the three serum samples of the 2 HCWs with positive viral cultures more than twelve days after symptom onset. We also noticed that 3 additional NPS samples positive for viral culture were from individuals with a contemporaneous nAb activity but at very low titers (Fig. 3B ). Retrospective SARS-CoV-2 infection assessment with serological testing. Out of the 252 RT-PCR-negative HCWs at initial screening, 190 were serologically tested 1 month after inclusion (V5). Among them, 7/190 were seropositive at V5 with both of the selected serological assays. At inclusion, no other respiratory pathogen was detected using the multiplex respiratory panel for these 7 individuals who developed mild respiratory symptoms (cough (5/7), shortness of breath (5/7), and rhinorrhea (3/7)). Interestingly, 4 of them suffered from ophthalmic pain, and 30 out of the 270 remaining participants tested with the multiplex respiratory panel did. A potential problem in the sampling quality did not appear to explain the negativity of the SARS-CoV-2 PCR from these 7 seropositive HCWs as the mean cell number in NPS of these individuals (4.0 10 4 cells/PCR), evaluated using a house-keeping gene, was not significantly different from that of the remaining seronegative HCWs (6.9 10 4 cells/PCR; p-value = 0.14). At inclusion, no anti-SARS-CoV-2 Ab had been detected for 6 of these 7 HCWs. The single HCW who was already seropositive at inclusion was, however, included later in the present study (at 24 days after symptom onset), which may explain the negativity of the PCR test. For the other 6 HCWs, the median (range) time between symptom onset and inclusion (i.e. RT-PCR screening) was 3 (1-4) days, which was similar for PCR positive patients, suggesting that the negative SARS-CoV-2 RT-PCR cannot be explained by a delayed diagnosis. Taken together, SARS-CoV-2 detection was potentially missed in 6/190 (3.15%) HCWs by RT-PCR performed on nasopharyngeal swabs. In the present study, investigating symptomatic HCWs, a high prevalence of COVID-19 was found, which is consistent with previous reports on this highly exposed population 7,28-30 . Regarding clinical findings, HCWs presented mostly a mild form of the disease, which can be explained by their relatively young age 31 . We confirmed the important proportion of smell and taste dysfunctions 7,32 , and a low rate of co-infection in SARS-CoV-2 positive patients was found. Higher rates of co-infection have been reported elsewhere, which may be explained by the differences in disease severity and in the timing of testing 33, 34 . A very low proportion of HCWs with a negative RT-PCR test at inclusion seroconverted one month later, suggesting the possibility of a false negative PCR test result at initial screening. Several factors can explain false negative results with RT-PCR, including the low sensitivity of some assays 35, 36 , the poor quality of samples, or the inappropriate timing of sampling 37 . However, the Cobas RT-PCR assay used for screening herein has been widely evaluated and no lack of sensitivity has been reported 38 . Furthermore, the quality of samples was checked using a cell control 39 in order to prevent false negative results due to low cell count. Taken together, our findings confirmed the low rate of false negative RT-PCR results using serology testing 40 , although initial reports have wrongly alerted the scientific community about the poor sensitivity of RT-PCR tests for COVID-19 screening 41 . Due to the design of the present study, it cannot be excluded that some individuals may have developed COVID-19 between inclusion and the serological testing performed one month later for negative patients at inclusion. Herein, a substantial (12%) part of the cohort was still RT-PCR positive 40 days post-symptom onset, which is consistent with the results from a large study conducted in mild-COVID-19 patients, in which 10% of patients had detectable RNA four weeks after symptom onset 14 . In a meta-analysis, a mean duration of RT-PCR positivity of 17 days has been reported with a maximum of 83 days 42 . It is important to emphasize that RT-PCR tests cannot distinguish between infectious virus and non-infectious RNA, and that RNA detection frequently outlasts the duration of infectivity. In the present study, upper respiratory samples from HCWs with positive RT-PCR 10 days after symptom onset (even those with significant viral loads) were mainly found negative in viral culture. Contagiousness is dependent on many factors, including the presence of upper respiratory symptoms, but seems unlikely 10 days after symptom onset in case of mild infection. Our findings are consistent with other studies that have reported a less than 6% probability of cultivating the virus after 10 or 15 days 20, 25 . Another large study on 3,790 SARS-CoV-2 positive samples inoculated for viral culture has found that a large majority of cultivable samples were collected during the first week 43 . This delay might be in line with the time required for the elicitation of nAbs, as suggested by the limited number of infectious virus found herein in samples with high viral load obtained after seroconversion, and by the contemporaneous presence of nAbs in the serum of most individuals with negative viral culture. Similarly, in a report on hospitalized patients, serum nAb titers have been independently associated with the absence of detection of infectious SARS-CoV-2. The latter study has also found that some hospitalized patients with a low titer of neutralizing antibodies could still have a positive culture, as also observed herein 20 . Taken together, the time elapsed since the onset of symptoms is crucial for discontinuing the isolation of HCWs with SARS-CoV-2 infection as underlined by CDC guidelines, which recommend to wait for a period of 10 days along with an improvement of the symptoms (https:// www. cdc. gov/ coron avirus/ 2019-ncov/ hcp/ dispo sition-hospi taliz ed-patie nts. html). Of note, a RT-PCR performed 10 days after symptom onset is not recommended for discontinuing isolation as it can be positive while patients are no longer infectious. A viral load threshold could be useful to assess the presence of infectious virus in clinical samples. Herein, the median viral load of positive culture specimens was 6.67 log 10 copies/mL. In a study among hospitalized patients, the median viral load was 8.14 log 10 copies/mL 20 in samples with infectious virus, while another study reported in children a median viral load of 7.2 log 10 copies/mL 44 . In addition to age 17 , the observed differences in viral load might be related to the severity of the disease, as higher viral loads are usually noticed in patients with severe forms 45 . Although the viral load can vary depending on the gene targeted by quantitative RT-PCR, a viral load of 5 to 6 log 10 copies/mL has been suggested as a proxy for the presence of infectious virus 18, 22 . In the present study, more than 90% of cultivable virus had a viral load > 4.5 log 10 cp/mL and were collected within 10 days after symptom onset. This viral load corresponded to a Ct value of 26 with the Argene RT-PCR kit targeting the N gene. For most clinical laboratories that cannot afford true quantitative RT-PCR results, Ct values might be helpful to assess the presence of infectious virus, as previously reported [22] [23] [24] [25] 27, 43 . However, as underlined by Han et al., Ct values are highly dependent on the RT-PCR kit used and can be affected by batch effect or PCR conditions. Therefore, Ct values should be interpreted with caution 46 , especially in taking into account the presence of upper respiratory symptoms and the time following symptom onset. The present study has several limitations. First, the inclusion period between April and June 2020, corresponded to the second half of the first epidemic wave in France, which led to a limited number of enrolled patients. Furthermore, the national lockdown may have had a substantial impact on the circulation of other respiratory viruses and the rate of co-infection is possibly underestimated. In addition, the date of symptom onset can be difficult to determine accurately. As asymptomatic HCWs were not screened, the prevalence of SARS-CoV-2 infection among HCWs was certainly underestimated in our cohort 4, 7, 30 . Finally, the results of viral culture must be considered with caution as this method can lack sensitivity, as its performance are highly dependent on the proper collection, transport, and rapidity of inoculation of samples on cells. Despite these limitations, the strength of the present study is to combine a clinical assessment with a comprehensive microbiological investigation in a cohort of COVID-19 patients. In particular, the longitudinal determination of SARS-CoV-2 viral load normalized using the HPRT1 housekeeping gene has not been performed so far. This method might be helpful for preventing misinterpretation related to a poor quality of sampling. In conclusion, the present study confirms the high prevalence of SARS-CoV-2 infection among symptomatic HCWs who mainly developed mild forms of COVID-19. Our data suggest that the normalized viral load can www.nature.com/scientificreports/ be useful for appreciating the infectiousness of infected HCWs. These patients are unlikely contagious 10 days after symptom onset, regardless of the viral load at diagnosis.Taken together, these data could be very helpful for defining rules for discontinuing isolation of HCWs and facilitating their safe return to work, which should contribute to reduce the risk of staff shortage. Study design. A prospective longitudinal cohort study was conducted at the university hospital of Lyon, France (Hospices Civils de Lyon, HCL) 47 including HCWs with symptoms suggesting a SARS-CoV-2 infection (at least one of the following symptoms: fever, respiratory symptoms, headaches, anosmia, ageusia). HCWs with a previous positive SARS-CoV-2 RT-PCR test were excluded. Clinical and microbiological data were collected for all included HCWs. The HCWs with negative SARS-CoV-2 PCR at inclusion came back one month later (V5) for SARS-CoV-2 serology testing ( Fig. 1; Supplementary Fig. 1 ). For COVID-19 HCWs, the SARS-CoV-2 load was determined weekly from inclusion until becoming negative by RT-PCR using SARS-CoV-2 R-gene kit (bioMérieux, Lyon, France). Nucleic acid extraction was performed from 0.2 mL NPS using NUCLISENS easyMAG and amplification was performed using Biorad CFX96. Quantitative viral load was determined using four internally developed quantification standards targeting the SARS-CoV-2N gene: QS1 to QS4 respectively at 2.5.10 6 , 2.5.10 5 , 2.5.10 4 , 2.5.10 3 copies/mL of a SARS-CoV-2 DNA standard. These QS were controlled and quantified using the Nanodrop spectrophotometer (ThermoFisher) and Applied Biosystems QuantStudio 3D Digital PCR. In parallel, NPS were tested using the CELL Control R-GENE kit (amplification of the HPRT1 housekeeping gene) that contains 2 quantification standards QS1 and QS2, at 10 4 copies/µL (50,000 cells/PCR i.e. 1.25.10 6 cells/mL in our conditions) and 10 3 copies/µL (5000 cells/PCR i.e. 1.25.10 5 cells/mL in our conditions) of DNA standard, respectively, to normalize the viral load according to the sampling quality. Viral culture was performed following interim biosafety guidelines established by WHO 48 from NPS in UTM-RT only; guanidine contained in the Cobas PCR medium tube prevented culture assay due to cytotoxic activity. RT-PCR positive NPS (64 NPS collected from 17 patients) were inoculated on confluent Vero cells (ATCC CCL-81) with Eagle's Minimum Essential Media (EMEM) supplemented with 2% penicillin-streptomycin, 1% L-glutamine, and 2% inactivated fetal bovine serum. Plates were incubated at 33 °C with 5% CO 2 for 96 h. The cytopathic effects (CPE) were monitored daily; samples were harvested when positive, while negative samples at 96 h underwent subculture on new plates. Culture supernatants were sampled at 2 h post-inoculation, at 96 h, and after an additional 96 h of subculture. RNA from supernatants was extracted using the automated MGISP-960 workstation using MGI Easy Magnetic Beads Virus DNA/RNA Extraction Kit (MGI Tech, Marupe, Latvia), and SARS-CoV-2 detection was performed using TaqPath COVID-19 CE-IVD RT-PCR kit on a QuantStudio 5 System (Applied Biosystems, Thermo Fisher Scientific, Waltham, USA). The presence of anti-SARS CoV-2 antibodies was evaluated on serum samples using the Wantai SARS-CoV-2 Ab ELISA kit (Wantai, Beijing, China), which detects total antibodies, and the VIDAS SARS-COV-2 IgG test (bioMérieux, Lyon, France), according to the manufacturers' instructions. Positivity was established according to the threshold value recommended by each manufacturer. Neutralizing antibodies were quantified with a neutralization assay using lentiviral pseudotypes on serum samples. Briefly, gag/pol and luciferase plasmids were co-transfected with a SARS-CoV-2 full length S plasmid in HEK293T cells and pseudoviruses were harvested after 72 h. Serial dilutions of human serum were incubated with pseudoviruses at 37 °C for 1 h, then transferred onto HeLa-ACE2 cells in 96-well plates at 10 000 cells/well (Corning). Plates were incubated at 37 °C for 48 h and HeLa-ACE2 cells were further lysed using 1 × luciferase lysis buffer (Oz Biosciences), at room temperature for 1 h. Luciferase activity was measured by adding luciferase substrate (Oz Biosciences), according to the manufacturer's instructions. Luciferase intensity was then read using a TECAN luminometer. The results from this assay were expressed as the serum dilution required to reduce infection by 50% (neutralization titer). The median (interquartile range, IQR) was used to express continuous variables. The difference between groups was assessed using the Student's T test or Mann-Whitney U test, as appropriate. Categorical variables were expressed as count (percentage) and compared using the Chi-square test or Fisher's Normalized viral load Log 10 cp/mL = Log10 Number of SARS -CoV -2 copies per mL Number of cells per mL × 10 6 cells per mL Reasons for healthcare workers becoming infected with novel coronavirus disease 2019 (COVID-19) in China The impact of novel coronavirus SARS-CoV-2 among healthcare workers in hospitals: An aerial overview Report of the WHO-China Joint Mission on Coronavirus Disease COVID-19: PCR screening of asymptomatic health-care workers at London hospital Death from Covid-19 of 23 Health Care Workers in China Nosocomial outbreak of COVID-19 pneumonia in Wuhan, China COVID-19 in healthcare workers: A living systematic review and meta-analysis of prevalence, risk factors, clinical characteristics, and outcomes Characterization of SARS-CoV-2 ORF6 deletion variants detected in a nosocomial cluster during routine genomic surveillance Nosocomial transmission of COVID-19: A retrospective study of 66 hospital-acquired cases in a London teaching hospital Return to work for healthcare workers with confirmed COVID-19 infection Duration of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infectivity: When is it safe to discontinue isolation? Viral load of SARS-CoV-2 in clinical samples Spatial and temporal dynamics of SARS-CoV-2 in COVID-19 patients: A systematic review and meta-analysis Duration of SARS-CoV-2 RNA detection in COVID-19 patients in home isolation Temporal dynamics in viral shedding and transmissibility of COVID-19 Presymptomatic transmission of SARS-CoV-2-Singapore SARS-CoV-2 viral load peaks prior to symptom onset: A systematic review and individual-pooled analysis of coronavirus viral load from 66 studies Virological assessment of hospitalized patients with COVID-2019 SARS-CoV-2 shedding and infectivity Duration and key determinants of infectious virus shedding in hospitalized patients with coronavirus disease-2019 (COVID-19) SARS-CoV-2 detection, viral load and infectivity over the course of an infection Culture-based virus isolation to evaluate potential infectivity of clinical specimens tested for COVID-19 Predicting infectious SARS-CoV-2 from diagnostic samples Viral RNA load as determined by cell culture as a management tool for discharge of SARS-CoV-2 patients from infectious disease wards Duration of infectiousness and correlation with RT-PCR cycle threshold values in cases of COVID-19 Prolonged virus shedding even after seroconversion in a patient with COVID-19 Repeat COVID-19 molecular testing: Correlation of SARS-CoV-2 culture with molecular assays and cycle thresholds First experience of COVID-19 screening of health-care workers in England Comparing dynamics and determinants of SARS-CoV-2 transmissions among health care workers of adult and pediatric settings in central Paris scientificreports/ workers for SARS-CoV-2 highlights the role of asymptomatic carriage in COVID-19 transmission Actinobaculum bacteremia: A report of 12 cases Epidemiological and clinical characteristics of SARS-CoV-2 infections at a testing site in Early bacterial co-infection in ARDS related to COVID-19 Rates of co-infection between SARS-CoV-2 and other respiratory pathogens Performance Assessment of SARS-CoV-2 PCR Assays Developed by WHO Referral Laboratories Analytical sensitivity and efficiency comparisons of SARS-CoV-2 RT-qPCR primer-probe sets Current best practices for respiratory virus testing Clinical Evaluation of the cobas SARS-CoV-2 Test and a Diagnostic Platform Switch during 48 Hours in the Midst of the COVID-19 Pandemic Development of an efficient qRT-PCR assay for quality control and cellular quantification of respiratory samples Antibody responses to SARS-CoV-2 in patients with COVID-19 Correlation of chest CT and RT-PCR testing for coronavirus disease 2019 (COVID-19) in China: A report of 1014 cases SARS-CoV-2, SARS-CoV, and MERS-CoV viral load dynamics, duration of viral shedding, and infectiousness: a systematic review and meta-analysis. Lancet Microbe Correlation between 3790 qPCR positives samples and positive cell cultures including 1941 SARS-CoV-2 isolates Culture-competent SARS-CoV-2 in nasopharynx of symptomatic neonates, children, and adolescents Viral dynamics in mild and severe cases of COVID-19 RT-PCR for SARS-CoV-2: Quantitative versus qualitative COVID-SER study group. Assessment of serological techniques for screening patients for COVID-19 (COVID-SER): a prospective, multicentric study Laboratory biosafety guidance related to coronavirus disease We thank all the staff members of the occupational health and medicine department of the Hospices Civils de Lyon who contributed to the sample collection. We thank Virginie Pitiot, the Clinical Research Associate, for her excellent work. We thank all the technicians from the virology laboratory whose work made it possible to obtain all these data. We thank Karima Brahima and all the members of the clinical research and innovation department for their reactivity (DRCI, Hospices Civils de Lyon). We thank Come Barranger for his help regarding the implementation of the quantitative RT-PCR. We thank Hélène Boyer (DRCI, Hospices Civils de Lyon) for her help in manuscript preparation. And lastly, we thank all the health care workers for their participation in this clinical study. This study was supported by the Hospices Civils de Lyon and by the Fondation des Hospices Civils de Lyon. The bioMérieux employees were involved in data analysis, interpretation, and wrote the manuscript. bioMérieux provided qRT-PCr Argene kits and BioFire Respiratory 2.1 plus Panel (RP2.1plus) kits for the study. Several authors (KBP, FAF, GO, VC) are bioMérieux employees. AB has received a grant from bioMérieux and has served as consultant for bioMérieux. KBP, FAF, GO VC and AB were involved in data analysis, interpretation and wrote the article. The rest of the authors declare no conflict of interest.