key: cord-0992783-mtkz1koe authors: Yang, Yaoli; Murphy, Noreen E.; Long,, Micah T. title: Pandemic Bronchoscopy: A Technique to Improve Safety date: 2020-06-16 journal: Anesthesiology DOI: 10.1097/aln.0000000000003436 sha: ec1ea32e4604348e6f5ffdb21395914fe4ed2959 doc_id: 992783 cord_uid: mtkz1koe nan A Technique to Improve Safety To the Editor: T he spread of coronavirus disease 2019 and the concern for procedure-related aerosolization has inspired innovative techniques to minimize contamination and spread. For example, Markin et al. utilized a modification to a transesophageal echocardiography probe sheath setup to improve safety during transesophageal echocardiography use. 1 Similarly, a modified ultrasound probe cover can be utilized in intubated patients for the rare instances when bronchoscopy is required. Current guidelines recommend postponing all elective bronchoscopies and, when mandated, performing them in a negative pressure isolation room and with appropriate personal protective equipment. 2, 3 In addition to following these guidelines, and with the use of a disposable bronchoscope, safety can be enhanced by novel use of a modified ultrasound probe cover ( fig. 1 ). First, an elbow connector with bronchoscopy port is placed into an ultrasound probe cover, and small cuts are made into the cover for the elbow ports ( fig. 1, A and B ). Next, tape is used to create a seal at the ports ( fig. 1C ). It is easy to add a dressing into the probe cover at this time for later cleaning of the bronchoscopy camera or to assist in flushing the working channel, should it be required ( fig. 1C ). This completely seals the distal end of the bronchoscope setup. Once this is done, the elbow with bronchoscopy port should be connected to the ventilator circuit and endotracheal tube. The bronchoscope is then inserted into the probe cover, the proximal end sealed and bronchoscopy performed ( fig. 1D ). This creates a closed-circuit bronchoscopy setup, minimizing aerosolization to the environment, droplet spread, and contamination of the bronchoscopists' hands. When the procedure is complete, the elbow connector setup is removed and the disposable bronchoscope, ultrasound cover, and elbow are all disposed of as one ( fig. 1E) . Critically, this adaptation does not solve aerosolization and contamination when attaching the elbow connector with bronchoscopy port setup to the ventilator-patient circuit. For this portion of the procedure we advise speed, short-acting paralytic administration, consideration of tube clamping to decrease breaths into the atmosphere, and a towel and/or drape over the endotracheal tube during disconnection with or without adjunctive suction to this region. To our knowledge, this approach comes closest to a "closed circuit" setup using readily available equipment, and enables both ease of setup and disposal. Francom et al. described use of very large disposable drapes over mayo stands, IV, poles or metal bars to create a "bronchoscopy tent" in order to cover the bed, body, and head in the operating room. 4 This approach, however, is less efficient and not practical in the intensive care unit. Yaghchi et al. described the use of in-line suction system to assist during percutaneous tracheostomy, but the setup would not offer the mobility mandated for bronchoscopy and again is less practical in an intensive care unit environment. 5 Although this strategy augments safety, bronchoscopy is clearly a high-risk procedure for COVID-19 spread via droplets and aerosols. Any bronchoscopy should be warily considered and avoided whenever possible. If unavoidable, however, every technique at our disposal should be utilized to minimize patient, provider, and environmental transmission. Support was provided solely from institutional and/or departmental sources. Transesophageal echocardiography probe sheath to decrease provider and environment contamination Society for Advanced Bronchoscopy consensus statement and guidelines for bronchoscopy and airway management amid the COVID-19 pandemic The use of bronchoscopy during the COVID-19 pandemic: CHEST/ AABIP guideline and expert panel report Pediatric laryngoscopy and bronchoscopy during the COVID-19 pandemic: A four-center collaborative protocol to improve safety with perioperative management strategies and creation of a surgical tent with disposable drapes Percutaneous tracheostomy in patients with COVID-19: Sealing the bronchoscope with an in-line suction sheath The authors declare no competing interests.