key: cord-0990340-m3p09hf8 authors: Kao, Chyuan-Haur; Chen, Kuan-Lin; Chiu, Yi-Shiang; Hao, Lin Sang; Chen, Shih-Ming; Li, Ming-Hsien; Lee, Ming-Ling; Chen, Hsiang title: Comparison of NH(3) and N(2)O Plasma Treatments on Bi(2)O(3) Sensing Membranes Applied in an Electrolyte–Insulator–Semiconductor Structure date: 2022-02-05 journal: Membranes (Basel) DOI: 10.3390/membranes12020188 sha: 81dd96228561a76072659601f99709d9554f981e doc_id: 990340 cord_uid: m3p09hf8 In this study, bismuth trioxide (Bi(2)O(3)) membranes in an electrolyte–insulator–semiconductor (EIS) structure were fabricated with pH sensing capability. To optimize the sensing performance, the membranes were treated with two types of plasma—NH(3) and N(2)O. To investigate the material property improvements, multiple material characterizations were conducted. Material analysis results indicate that plasma treatments with appropriate time could enhance the crystallization, remove the silicate and facilitate crystallizations. Owing to the material optimizations, the pH sensing capability could be greatly boosted. NH(3) or N(2)O plasma treated-Bi(2)O(3) membranes could reach the pH sensitivity around 60 mV/pH and show promise for future biomedical applications. Fifty years ago, the first ion-sensitive field-effect transistor (ISFET) was invented by Bergveld in 1970 [1, 2] . Following the invention, semiconductor-based ion sensing technology [1] [2] [3] has been developed since the late 20th century. Among various types of ion sensing semiconductor devices, electrolyte-insulator-semiconductor (EIS) sensors with rapid response, high reliability and simple structure have been intensively studied [4] . Because of low capacitance and poor electrochemical properties, SiO 2 has been replaced by various oxides to improve the membranes properties [5] . Recently, Ta 2 O 5 [6] , WO 3 [7] , and La 2 O 3 [8] have emerged as novel membrane materials [9] . However, to further boost the membrane sensing performance, novel materials and new treatments are worthwhile to be explored. Bismuth trioxide (Bi 2 O 3 ) with a bandgap around 2.5 eV has been utilized as photocatalyst [10] , super capacitors, and gas sensor materials [11] . However, Bi 2 O 3based pH sensing membranes [12] have not been clearly reported, yet. Furthermore, to enhance the sensing capability, Bi 2 O 3 membranes were treated with two types of plasma-NH 3 and N 2 O [13, 14] . To investigate the improvement of the treatment, multiple material analysis techniques including X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and secondary ion mass spectrometry (SIMS) were performed. Material analysis results indicate that Bi 2 O 3 membranes treated with NH 3 Membranes 2022, 12 , 188 2 of 20 plasma for 3 min and N 2 O plasma for 1 min had strong crystallization, silicate suppression, high grainization, and effective nitrogen passivation. Moreover, the pH sensing measurements [15] indicate that Bi 2 O 3 membranes treated in these plasma treatment conditions had high pH sensitivity around 60 mV/pH and high linearity close to 100%. Hysteresis and drift [16] rate evaluation also reveal that the membrane treated in these conditions had the lowest hysteresis voltage and the smallest drift rate. NH 3 and N 2 O plasma treatments could incorporate the nitrogen atoms into the deep part of the devices to fix the defects and eliminate the silicates. According to previous reports [17, 18] , plasma treatment can eliminate the silicate layer because, because silicates can have chemical reaction and transform from SiOx with dangling bonds to Si-O-Si bonds. The atoms in the plasma such as F or N can facilitate the combination of the silicon or oxygen dangling bonds to form well-crystallized Si-O-Si [19] . Therefore, silicate can be reduced, and near-perfect crystals can replace the silicate. The effective electric field across the membranes can be enhanced so the sensing capability can be improved [20, 21] . Moreover, the nitrogen incorporation in the bulks may form NH 2 bond to strengthen the chemical bonds and improve the material properties [22] . On the other hand, plasma treatment of the sensing film could cause an EIS structure sensitive to H + ions [23] because the increase of the metal ions produced on the surface sites to decrease the diffusion capacitance in the solution and enhance the sensitivity. Furthermore, based on the Gouy-Chapman-Stern model [24, 25] , the sensing parameter β is proportional to the density of surface states, as shown in (1), where Ns is the number of surface sites per unit surface area and C DL is the double layer capacitance. Therefore, the sensing capability can be enhanced by NH 3 and N 2 O plasma treatments. Owing to high sensitivity, fair linearity, stable response, Bi 2 O 3 -based EIS membranes [26] with NH 3 or N 2 O plasma treatments show promise for future industrial biomedical sensing [27] applications. To prepare the EIS sensor with Bi 2 O 3 sensing film, 3.95 g of bismuth nitrate (Bi(NO 3 ) 3 ·5H 2 O) was dissolved in 20 mL of nitric acid with the solution concentration of 1 M. The sol-gel solution was dropped onto the cleansed p-Si substrate. Then, a Bi 2 O 3 film formed on it, and then the plasma treatments were performed. The samples were treated with NH 3 and N 2 O plasma at 100 W RF power and 500 mTorr processing pressure for 1 min, 3 min, and 6 min, respectively. Then, an Al film with a thickness of 300 nm was deposited on the back of the silicon wafer and the silicone glue was used to define the sensing window, and the device was glued to be fixed on a PCB board. Finally, AB glue was used for packaging to prevent oxidation. The device structure is illustrated in Figure 1 . To examine the crystalline structures of the membranes, XRD was used. Figure 2a shows the X-ray diffraction patterns of Bi2O3 film after NH3 plasma treatments for various times. The two diffraction peaks BiO (012) and Bi2O3 (200) are located at 27.8° and 32.6°, respectively. The as-deposited sample shows a peak of BiO. After NH3 plasma treatment for 3 min, the sample shows the strongest peak of Bi2O3 (200) among all the samples. By contrast, Figure 2b shows the X-ray diffraction analysis of the Bi2O3 film after N2O plasma treatments for various times. The diffraction peaks BiO (012) and Bi2O3 (200) are located at 27.8° and 32.6°, respectively. The as-deposited sample also shows a peak of BiO. After N2O plasma treatment for 1 min, the sample shows the strongest Bi2O3 (200) peak among all the samples. With the increase of the plasma treatment time, the intensity of the Bi2O3 (200) peak gradually decreased. (a) To examine the crystalline structures of the membranes, XRD was used. Figure 2a shows the X-ray diffraction patterns of Bi 2 O 3 film after NH 3 plasma treatments for various times. The two diffraction peaks BiO (012) and Bi 2 O 3 (200) are located at 27.8 • and 32.6 • , respectively. The as-deposited sample shows a peak of BiO. After NH 3 plasma treatment for 3 min, the sample shows the strongest peak of To examine the crystalline structures of the membranes, XRD was used. Fig shows the X-ray diffraction patterns of Bi2O3 film after NH3 plasma treatments for times. The two diffraction peaks BiO (012) and Bi2O3 (200) are located at 27.8° an respectively. The as-deposited sample shows a peak of BiO. After NH3 plasma tre for 3 min, the sample shows the strongest peak of Bi2O3 (200) among all the sampl By contrast, Figure 2b shows the X-ray diffraction analysis of the Bi2O3 film af plasma treatments for various times. The diffraction peaks BiO (012) and Bi2O3 (2 located at 27.8° and 32.6°, respectively. The as-deposited sample also shows a peak After N2O plasma treatment for 1 min, the sample shows the strongest Bi2O3 (20 among all the samples. With the increase of the plasma treatment time, the intensit Bi2O3 (200) peak gradually decreased. Furthermore, XPS analysis was used to study the chemical bonding state of th sensor film after NH3 and N2O plasma treatments. The O1s spectra of the sample NH3 plasma treatments is shown in Figure 3a . The as-deposited and annealed sa have 4 peak fitting curves, namely SiO2 (531.8 eV), silicate (531.4 eV), oxygen defect eV), and Bi-O (529 eV). After the NH3 plasma treatment, the oxygen defects and s were significantly reduced. Because NH3 plasma treatment could dope N into the improve dangling bonds and strain bonds, the sensing properties were improved. The O1s spectra of the samples after N2O plasma treatment is shown in Fig The as By contrast, Figure 2b shows the X-ray diffraction analysis of the Bi 2 O 3 film after N 2 O plasma treatments for various times. The diffraction peaks BiO (012) and Bi 2 O 3 (200) are located at 27.8 • and 32.6 • , respectively. The as-deposited sample also shows a peak of BiO. After N 2 O plasma treatment for 1 min, the sample shows the strongest Bi 2 O 3 (200) peak among all the samples. With the increase of the plasma treatment time, the intensity of the Bi 2 O 3 (200) peak gradually decreased. Furthermore, XPS analysis was used to study the chemical bonding state of the Bi 2 O 3 sensor film after NH 3 and N 2 O plasma treatments. The O1s spectra of the samples after NH 3 plasma treatments is shown in Figure 3a . The as-deposited and annealed samples have 4 peak fitting curves, namely SiO 2 (531.8 eV), silicate (531.4 eV), oxygen defect (530.3 eV), and Bi-O (529 eV). After the NH 3 plasma treatment, the oxygen defects and slicates were significantly reduced. Because NH 3 plasma treatment could dope N into the film to improve dangling bonds and strain bonds, the sensing properties were improved. The O1s spectra of the samples after N 2 O plasma treatment is shown in Figure 3b . The as-deposited and annealed samples have three peak fitting curves, namely, silicate (531.4 eV), oxygen defect (530.3 eV), and Bi-O (529 eV). After N 2 O plasma treatment, the oxygen defects and silicates were significantly suppressed. Since N 2 O plasma treatment could incorporate N into the film, mitigate dangling bonds and strain bonds, and strengthen the film structure, the sensing behaviors could be improved. Results indicate that N atoms in the plasma could transform SiO x with dangling bonds to form well-crystallized Si-O-Si. Figure 4a -d shows the atomic force microscope (AFM) images of the Bi 2 O 3 film after NH 3 plasma treatments for various times, and Figure 4e -h shows the atomic force microscope (AFM) images of the Bi 2 O 3 film after N 2 O plasma treatments for various times. The root mean square (Rms) roughness of the sample without plasma treatment and of the samples after NH 3 plasma treatment for 1, 3, and 6 min were 1.31, 5.32, 15.56, and 11.33 nm, respectively. The root mean square (Rms) roughness of the sample without plasma treatment and of the samples after N 2 O plasma treatment for 1, 3, and 6 min were 1.31, 3.9, 3.83, and 3.21 nm, respectively. After 3 min of NH 3 plasma treatment of 1 min of N 2 O plasma treatment, the Bi 2 O 3 film has the largest Rms value. The incorporation of N can passivate the defects improve the crystalline structure, and strengthen the grainization, thereby increasing the surface sites and improving the sensing characteristics. (531.4 eV), oxygen defect (530.3 eV), and Bi-O (529 eV). After N2O plasma treatment, the oxygen defects and silicates were significantly suppressed. Since N2O plasma treatment could incorporate N into the film, mitigate dangling bonds and strain bonds, and strengthen the film structure, the sensing behaviors could be improved. Results indicate that N atoms in the plasma could transform SiOx with dangling bonds to form well-crystallized Si-O-Si. Figure 4e -h shows the atomic force microscope (AFM) images of the Bi2O3 film after N2O plasma treatments for various times. The root mean square (Rms) roughness of the sample without plasma treatment and of the samples after NH3 plasma treatment for 1, 3, and 6 min were 1.31, 5.32, 15.56, and 11.33 nm, respectively. The root mean square (Rms) roughness of the sample without plasma treatment and of the samples after N2O plasma treatment for 1, 3, and 6 min were 1.31, 3.9, 3.83, and 3.21nm, respectively. After 3 min of NH3 plasma treatment of 1 min of N2O plasma treatment, the Bi2O3 film has the largest Rms value. The incorporation of N can passivate the defects improve the crystalline structure, and strengthen the grainization, thereby increasing the surface sites and improving the sensing characteristics. To examine the surface morphologies, Figure 5a -f shows the field emission scanning electron microscope (FESEM) images of the deposited Bi 2 O 3 film and the Bi 2 O 3 film after NH 3 and N 2 O plasma treatments. After 1 min of NH 3 plasma treatment, irregular crystals with uneven distribution were produced on the surface. After 3 min of plasma treatment, the crystals became denser. After 6 min of plasma treatment, the crystals became sparsely distributed again. Therefore, the NH 3 plasma treatment in 3 min had the best material properties. (FESEM) images of the deposited Bi 2 O 3 film and the Bi 2 O 3 film before and after N 2 O plasma treatment for 1 min are shown in Figure 5e ,f. After N 2 O plasma treatments for 1 min, the crystallization of the film became obvious. Due to the incorporation of N, the dangling bonds and strain bonds in the film can be fixed, and the crystalline structure could be strengthened, so the sensing could be improved. samples after NH3 plasma treatment for 1, 3, and 6 min were 1.31, 5.32, 15.56, and 11.33 nm, respectively. The root mean square (Rms) roughness of the sample without plasma treatment and of the samples after N2O plasma treatment for 1, 3, and 6 min were 1.31, 3.9, 3.83, and 3.21nm, respectively. After 3 min of NH3 plasma treatment of 1 min of N2O plasma treatment, the Bi2O3 film has the largest Rms value. The incorporation of N can passivate the defects improve the crystalline structure, and strengthen the grainization, thereby increasing the surface sites and improving the sensing characteristics. To examine the surface morphologies, Figure 5a -f shows the field emission scanning electron microscope (FESEM) images of the deposited Bi2O3 film and the Bi2O3 film after NH3 and N2O plasma treatments. After 1 min of NH3 plasma treatment, irregular crystals with uneven distribution were produced on the surface. After 3 min of plasma treatment, the crystals became denser. After 6 min of plasma treatment, the crystals became sparsely distributed again. Therefore, the NH3 plasma treatment in 3 min had the best material properties. (FESEM) images of the deposited Bi2O3 film and the Bi2O3 film before and after In addition, the images of the two types of plasma treatments are compared. It can be found that the uniformity of the film after N2O plasma treatments is more uniform than that of the Bi2O3 film after NH3 plasma treatment. Therefore, Bi2O3 film maybe more stable after N2O plasma treatments than NH3 plasma treatments. In addition, the images of the two types of plasma treatments are compared. It can be found that the uniformity of the film after N 2 O plasma treatments is more uniform than that of the Bi 2 O 3 film after NH 3 plasma treatment. Therefore, Bi 2 O 3 film maybe more stable after N 2 O plasma treatments than NH 3 plasma treatments. Figure 6a ,b shows the SIMS of the samples with NH 3 and N 2 O plasma treatment for various time. It can be seen that as the plasma treatment time increased, the thickness of the sensing film decreased. As the film after plasma treatment would be etched with the increase of the plasma treatment time, the sensing characteristics were slightly reduced. On the other hand, nitrogen atoms can be introduced into the Bi 2 O 3 /Si interface by NH 3 and N 2 O plasma treatment as shown in the two SIMS profiles. These accumulated nitrogen atoms can passivate the defects of the interface. Since the incorporation of N can improve the dangling bonds and strain bonds of the film, the sensing performance is improved. Membranes 2021, 11, x FOR PEER REVIEW 8 of Figure 6a ,b shows the SIMS of the samples with NH3 and N2O plasma treatment f various time. It can be seen that as the plasma treatment time increased, the thickness the sensing film decreased. As the film after plasma treatment would be etched with t increase of the plasma treatment time, the sensing characteristics were slightly reduce On the other hand, nitrogen atoms can be introduced into the Bi2O3/Si interface by N and N2O plasma treatment as shown in the two SIMS profiles. These accumulated nitr gen atoms can passivate the defects of the interface. Since the incorporation of N can im prove the dangling bonds and strain bonds of the film, the sensing performance is im proved. As the two plasma treatments are compared, it can be found that the amount of nitrogen incorporated after the N 2 O plasma treatment was relatively stable, and the nitrogen content only slightly decreased with the increase of the plasma time. Therefore, the N 2 O plasma treatment had relatively stable sensing characteristics. To assess the pH sensing behaviors, C-V curves of Bi 2 O 3 after different NH 3 and N 2 O plasma treatment conditions were measured. Figure 7a -d shows C-V curves of Bi 2 O 3 after NH 3 plasma for various times. The sensitivity value without NH 3 plasma treatment was 42.66 mV/pH, and the linearity was 94.483%. After NH 3 plasma treatment for 1 min, 3 min and 6 min, the sensitivity values became 30.87, 59.84 and 40.83 mV/pH, respectively, and the linearity values became 84.45%, 99.25% and 97.17%. As for the sensitivity among the Bi 2 O 3 samples with different NH 3 plasma time, it can be found that the Bi 2 O 3 sensor film had the highest sensitivity after NH 3 plasma treatment for the 3 min sample. Consistent with the FESEM images, the film treated in this condition produced densely arranged and layered crystals, which produced a larger contact area and increased sensitivity. After 3 min of NH 3 plasma treatment, there were small and dense Bi 2 O crystals, thereby increasing the sensitivity of the sensing film. Figure 7e -h shows the C-V curve of Bi 2 O 3 after different N 2 O plasma treatment time. After N 2 O plasma treatment for 1 min, 3 min and 6 min, the sensitivity were 60.43, 59.91 and 59.8 mV/pH, respectively. The linearity was 99.82%, 98.97% and 99.64%. As for the sensitivity of Bi 2 O 3 under different N 2 O plasma time, it can be found that the sensitivity of the Bi 2 O 3 film after N 2 O plasma for various times and the samples in all the conditions were improved, consistent with FESEM images of the uniform distributed crystals under various plasma treatment conditions. After N 2 O plasma treatment, surface defects could be passivated, and dangling bonds and strain bonds can be fixed. Therefore, plasma treatments could improve the material properties and enhance the crystalline structure and grainization effect, and thereby increasing sensitivity. Membranes 2021, 11, x FOR PEER REVIEW As the two plasma treatments are compared, it can be found that the amo trogen incorporated after the N2O plasma treatment was relatively stable, and gen content only slightly decreased with the increase of the plasma time. Ther N2O plasma treatment had relatively stable sensing characteristics. To assess the pH sensing behaviors, C-V curves of Bi2O3 after different NH plasma treatment conditions were measured. Figure 7a -d shows C-V curves of B NH3 plasma for various times. The sensitivity value without NH3 plasma treat 42.66 mV/pH, and the linearity was 94.483%. After NH3 plasma treatment for 1 m and 6 min, the sensitivity values became 30.87, 59.84 and 40.83 mV/pH, respecti the linearity values became 84.45%, 99.25% and 97.17%. As for the sensitivity a Bi2O3 samples with different NH3 plasma time, it can be found that the Bi2O3 se had the highest sensitivity after NH3 plasma treatment for the 3 min sample. C with the FESEM images, the film treated in this condition produced densely arra layered crystals, which produced a larger contact area and increased sensitivit min of NH3 plasma treatment, there were small and dense Bi2O crystals, thereb ing the sensitivity of the sensing film. Figure 7e -h shows the C-V curve of Bi2O3 after different N2O plasma treatm After N2O plasma treatment for 1 min, 3 min and 6 min, the sensitivity were 60 and 59.8 mV/pH, respectively. The linearity was 99.82%, 98.97% and 99.64%. A sensitivity of Bi2O3 under different N2O plasma time, it can be found that the s of the Bi2O3 film after N2O plasma for various times and the samples in all the c were improved, consistent with FESEM images of the uniform distributed cryst various plasma treatment conditions. After N2O plasma treatment, surface defe be passivated, and dangling bonds and strain bonds can be fixed. Therefore, plas ments could improve the material properties and enhance the crystalline stru grainization effect, and thereby increasing sensitivity. To investigate the reliability of the membranes, Figure 8a shows the hysteresis voltage of the Bi 2 O 3 sensing film after NH 3 and N 2 O plasma treatment. The Bi 2 O 3 sensing film without plasma had a hysteresis voltage of 22.49 mV, and the hysteresis voltage after 1, 3, and 6 min of NH 3 plasma were 24.18, 3.31, and 16.13 mV, respectively. As for the Bi 2 O 3 sensing film treated by NH 3 plasma at different times, the NH 3 plasma treatment for 3 min shows the lowest hysteresis voltage. Since the incorporation of N with NH 3 plasma treatment can passivate the defects, thereby inhibiting the diffusion of reactive ions and delaying the reference voltage response. Combined with the XPS analysis, it can be seen that the 3 min NH 3 plasma had the least oxygen vacancies, and the Bi-O bond was the strongest. After calculation, it can be known that the 3 min NH 3 plasma has the lowest Bi 2+ content, so the sensor film shows low hysteresis voltage. The hysteresis voltage of the Bi 2 O 3 sensing film after N 2 O plasma is shown in Figure 8b . The hysteresis voltage of the Bi 2 O 3 sensing film without plasma was 22.49 mV, and the hysteresis voltage after 1, 3, and 6 min of N 2 O plasma were 2.31, 3.01, and 4.87 mV, respectively. It was observed that after 1 min of N 2 O plasma the membrane had a lower hysteresis voltage compared with all the other samples. As the plasma treatment time increased, the hysteresis voltage gradually increased because the crystals gradually became smaller, which caused the hysteresis voltage to rise. Furthermore, Figure 8c ,d shows the drift coefficient of the Bi 2 O 3 sensing film after NH 3 and N 2 O plasma, respectively. The drift coefficient is an important parameter describing the long-term stability of the sensor. In order to sense the long-term reliability of the film, we placed the Bi 2 O 3 sensing film treated with plasma treatments in a pH7 solution for 12 h to obtain the drift rate of the sensing film. The drift rate of the Bi 2 O 3 sensing film without plasma was 23.58 mV/hr, and the drift rate of the sensing film with NH 3 plasma after 1, 3, and 6 min were 20.7, 2.57, 15.09 mV/hr. It can be seen that the sensing film after 3 min of NH 3 plasma had the lowest drift rate. This is because NH 3 plasma could effectively passivate the defects, which allow ions to adhere, thereby inhibiting the diffusion of reactive ions and varying the reference voltage response. Therefore, the drift rate was reduced. Figure 8d shows the drift coefficient of the Bi 2 O 3 sensing film after N 2 O plasma. The drift rate of Bi 2 O 3 sensing film without plasma was 23.58 mV/hr, and the sensing film after N 2 O plasma for 1, 3, and 6 min were 2.45, 3.44, and 7.57 mV/hr. The sensing film of N 2 O plasma had the lowest drift rate in the sample with N 2 O plasma for 1 min. Bi2O3 EIS sensing membranes in EIS structures were fabricated. To boost the performance, NH3 and N2O plasma treatment were performed on the membran results indicated that the sample treated with NH3 plasma for 3 min and the samp Bi 2 O 3 EIS sensing membranes in EIS structures were fabricated. To boost the sensing performance, NH 3 and N 2 O plasma treatment were performed on the membranes. The results indicated that the sample treated with NH 3 plasma for 3 min and the sample with N 2 O plasma treatment for 1 min had higher sensitivity than all the other conditions. Multiple material characterizations confirmed the enhancement of crystallization, and the removal of the defects may cause the improvements of the sensing behaviors owing to nitrogen passivation in the device. The plasma treatments could cause N atoms to incorporate into the bulks and the silicate could be transformed to well-crystallized films. Furthermore, plasma treatment could enhance grainization, which increased the density of the sensing surface sites, thereby boosting the sensing behaviors. Therefore, NH 3 or N 2 O plasma treated-Bi 2 O 3 membranes could reach the pH sensitivity around 60 mV/pH and show promise for future biomedical applications. Development of an ion-sensitive solid-state device for neurophysiological measurements High-performance extended-gate ion-sensitive field-effect transistors with multi-gate structure for transparent, flexible, and wearable biosensors A Review of Semiconductor Based Ionising Radiation Sensors Used in Harsh Radiation Environments and Their Applications Zinc Oxide Nanorod Electrolyte-Insulator-Semiconductor Sensor for Enhanced 2-Methoxyethanol Selectivity Effect of functionalized SiO2 toward proton conductivity of composite membranes for PEMFC application Deposition and characterization of RF-sputtered-Ta 2 O 5 thin films for O 2 reduction reaction in polymer electrolyte membrane fuel cells (PEMFC) Sandwich Nylon/stainless-steel/WO 3 membrane for the photoelectrocatalytic removal of Reactive Red 120 dye applied in a flow reactor Preparation of La 2 O 3 by ion-exchange membrane electrolysis of LaCl 3 aqueous solution The development and study of novel membrane materials based on polyphenylene isophthalamide-Pluronic F127 composite In-situ synthesis of direct solid-state dual Z-scheme WO 3 /g-C 3 N 4 /Bi 2 O 3 photocatalyst for the degradation of refractory pollutant Hydrothermal synthesis of mesoporous ZnO microspheres as NOX gas sensor materials-Calcination effects on microstructure and sensing performance Synthesis of Bismuth Doped Yttria Stabilized Zirconia Electrolyte and Study of Ionic Conductivity Plasma-enhanced NH 3 synthesis over activated carbon-based catalysts: Effect of active metal phase Plasma and catalyst for the oxidation of NOx Recent progress in electrochemical pH-sensing materials and configurations for biomedical applications Self-compensated driving circuit for reducing drift and hysteresis in Force Sensing Resistors Suppression of interfacial reaction for HfO 2 on silicon by pre-CF 4 plasma treatment The interfaces of lanthanum oxide-based subnanometer EOT gate dielectrics Effect of Combined Hydrophilic Activation on Interface Characteristics of Si/Si Wafer Direct Bonding Nanoporous dielectric films: Fundamental property relations and microelectronics applications. In Interlayer Dielectrics for Semiconductor Technologies Electrolyte-gated organic field effect transistor with functionalized lipid monolayer for novel sensors Development of thin film nanocomposite membrane incorporated with mesoporous synthetic hectorite and MSH@ UiO-66-NH 2 nanoparticles for efficient targeted feeds separation, and antibacterial performance NH 3 Plasma-Treated Magnesium Doped Zinc Oxide in Biomedical Sensors with Electrolyte-Insulator-Semiconductor (EIS) Structure for Urea and Glucose Applications A Gouy-Chapman-Stern model of the double layer at a (metal)/(ionic liquid) interface On the Gouy-Chapman-Stern model of the electrical double-layer structure with a generalized Boltzmann factor Installation and Optimisation of a Test Stand for Solid Oxide Fuel Cells and Solid Oxide Electrolyser Cells Internet of Things-based Smart Healthcare Systems and Wireless Biomedical Sensing Devices in Monitoring, Detection, and Prevention of COVID-19 There are no conflict of interest to declare. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the result.