key: cord-0989845-gfkyqepu authors: Bonell, Ana; Nadjm, Behzad; Samateh, Tida; Badjie, Jainaba; Perry-Thomas, Robyn; Forrest, Karen; Prentice, Andrew M.; Maxwell, Neil S. title: Impact of Personal Cooling on Performance, Comfort and Heat Strain of Healthcare Workers in PPE, a Study From West Africa date: 2021-09-01 journal: Front Public Health DOI: 10.3389/fpubh.2021.712481 sha: 6d8b726e4000d2635d6094ff4576a6b0e07f79fd doc_id: 989845 cord_uid: gfkyqepu Background: Personal protective equipment (PPE) is an essential component of safely treating suspected or confirmed SARS-CoV-2 patients. PPE acts as a barrier to heat loss, therefore increasing the risk of thermal strain which may impact on cognitive function. Healthcare workers (HCWs) need to be able to prioritize and execute complex tasks effectively to ensure patient safety. This study evaluated pre-cooling and per-cooling methods on thermal strain, thermal comfort and cognitive function during simulated emergency management of an acutely unwell patient. Methods: This randomized controlled crossover trial was run at the Clinical Services Department of the Medical Research Unit The Gambia. Each participant attended two sessions (Cool and Control) in standard PPE. Cool involved pre-cooling with an ice slurry ingestion and per-cooling by wearing an ice-vest external to PPE. Results: Twelve participants completed both sessions. There was a significant increase in tympanic temperature in Control sessions at both 1 and 2 h in PPE (p = 0.01). No significant increase was seen during Cool. Effect estimate of Cool was −0.2°C (95% CI −0.43; 0.01, p = 0.06) post 1 h and −0.28°C (95% CI −0.57; 0.02, p = 0.06) post 2 h on tympanic temperature. Cool improved thermal comfort (p < 0.001), thermal sensation (p < 0.001), and thirst (p = 0.04). No difference on cognitive function was demonstrated using multilevel modeling. Discussion: Thermal strain in HCWs wearing PPE can be safely reduced using pre- and per-cooling methods external to PPE. SARS-CoV-2 continues to cause significant mortality and morbidity worldwide (1) . Healthcare systems and healthcare workers (HCW) must ensure effective and timely treatment of cases without compromising safety (2) . For HCWs this involves use of personal protective equipment (PPE) when treating suspected or confirmed cases, following international guidelines (3, 4) . PPE is a physical barrier preventing viral contamination, however it also reduces evaporative and radiative heat loss leading to potential uncompensable heat load, thermal strain and discomfort (5) . Acknowledging this, the Center for Disease Control and Prevention (CDC), the American Conference of Governmental Industrial Hygienists (ACGIH) and the International Organization for Standardization (ISO) have all produced guidelines to ensure workers' safety in thermal extremes (6) (7) (8) . However even if these guidelines are known about and adhered to, recent studies have questioned whether the measures are sufficient in tropical climates (9, 10) . In tropical regions there are several factors that increase the risk of thermal strain. Ambient environmental conditions are likely to be high. For example in The Gambia, West Africa, average daily temperatures range from 29 to 34 • C with annual average levels of relative humidity at 68%, significantly higher than recommended temperature and humidity for indoor surgical operating theaters (25 • C and 60%) (11) . Additionally, in most healthcare facilities in resource-limited tropical settings, natural ventilation systems alone are often relied upon, with limited availability of air-conditioning (12) . Wall-mounted airconditioning units, where available, recirculate air without a HEPA filter and are advised against by the WHO (13) . Ceiling or standing fans are not recommended in any but single occupancy rooms. Therefore, there is a high environmental heat load that is difficult to mitigate. Concerns regarding shortages of PPE mean that healthcare workers often wear PPE for prolonged periods. The length of time in PPE increases the risk of dehydration, thermal strain, physical exhaustion and may compromise decision making (14) (15) (16) . During this current pandemic, many HCW are wearing PPE for 4 or more hours (17). The most appropriate personal cooling mechanism for healthcare workers in PPE likely differs depending on work load, environmental stressors and resources (5) . Comparative evidence from industry and athletes have shown internal, external and mixed-method cooling to reduce thermal strain (18) (19) (20) (21) (22) (23) (24) (25) . Pre-cooling (reducing body temperature prior to heat exposure) with ice slurry ingestion (ISE) lowers core temperature and increases heat storage capacity, delaying the onset of sweating and risk of dehydration, reducing thermal discomfort and improving endurance capabilities (26, 27) . ISE is more effective than water ingestion at absorbing heat and can therefore have a greater impact on reducing body temperature (28) . It also improves perception of effort, cognitive function and fatigue (29) . However, the effects of ISE are time-limited (30) . Ice-vests have been shown to improve endurance performance and thermal comfort via changes in skin temperature, although they do not lower core temperature as ISE does (18, 21) . Mixed methods of cooling, including pre and per (during)-cooling methods have been found to be the most effective (18) . Studies of ice-vests with PPE to date have placed the ice-vests under PPE (18, 21) , however after several hours the ice packs will melt and will then add to physical discomfort and energy cost. A simple effective cooling mechanism for HCW in PPE has not been established. Despite conflicting evidence of the impact of heat strain on simple mental tasks, there is growing consensus that above 38.2 • C core temperature, dual-task performance and complex-task sharing are negatively impacted by heat strain (31) (32) (33) (34) . This is particularly relevant to HCWs who are often caring for multiple patients, need to be able to prioritize tasks effectively and perform accurate calculations, all under stress. There is little literature on the impact of heat stress on HCWs' ability to perform routine tasks in tropical conditions (11) . Studies from temperature-controlled settings give conflicting evidence of the effect of PPE on HCW emergency tasks performance, where clinical tasks performed by specialists appear to be preserved from the impact of the physical effects of PPE (i.e., anesthetists vs. clinicians on intubation) (35, 36) . One study on surgeons' ability to perform laparoscopic operative tasks at 26 vs. 19 • C found a significant increase in both physical demand and distractibility at higher temperatures (37) . Another study evaluating different PPE suits at 22 and 28 • C did not show any impact on simulated HCW tasks (38) . We hypothesize that PPE-induced thermal strain impairs complex task performance by HCWs and this effect will be mitigated by personal cooling methods. This study aimed to be directly transferable to clinical practice and therefore was simple and pragmatic, assessed the risk of compromising PPE and assessed the ability to perform life-saving procedures. We evaluated the use of a combination of pre-cooling with ISE ingestion and per-cooling via ice-vests external to PPE on thermal strain, thermal comfort and cognitive function during simulated emergency management of an acutely unwell patient. We enrolled 16 HCWs from the pool of staff working on the COVID wards in the Clinical Services Department of the Medical Research Unit The Gambia (MRCG). We used convenience sampling of non-pregnant, non-shielding staff. Written informed consent was given by all participants. Baseline characteristics are presented in Table 1 . All participants were long-term residents of The Gambia. All experiments described below took place around the usual staff shifts. This was a randomized controlled crossover, repeated measures experiment of ISE and ice-vests (Cool) on thermal strain, thermal comfort, and cognitive function in HCW in PPE. Each participant was invited to attend two sessions (Cool vs. Control) at least 4 days apart to minimize any further acclimation effect from repeated heat exposures, at the same time of day to avoid the effect of diurnal rhythms on core temperature. Sample size calculation was based on results from Quinn et al.'s study of cooling methods in PPE in environmental conditions designed to reproduce conditions in West Africa (40) . In this study core temperature in control (38.86C) and ice-vest intervention (37.94C) gave an effect size of 0.92. Taking an alpha of 0.05 and a power of 0.8, a minimum sample size requirement of 12 would detect a similar difference. Sessions occurred in an unoccupied hospital ward. Environmental conditions were measured using the HT200: Heat Stress WBGT (Wet Bulb Globe Temperature) Meter (Extech R , NH, USA). The first hour mimicked a teaching ward round covering the WHO Basic Emergency Care course and the Advanced Life Support Algorithm from the UK Resuscitation Council (41, 42) . This hour was spent standing or sitting taking notes with an estimated metabolic equivalent task (MET) of 1.8. There followed a revision quiz and simulation training. During the simulation all participants had to deliver effective cardiopulmonary resuscitation (CPR) and bag-mask ventilation to a mannequin. The estimated METs of CPR were 5.7 (43) . Sessions were delivered by an Advanced Life Support Instructor and medical doctor and were tailored to locally available equipment. Sessions lasted ∼2 h, with some extension to allow completion of the cognitive function tests. All participants wore standard PPE for treating suspected or confirmed covid-19 patients, as specified by MRCG@LSHTM. This consisted of scrubs under category III type 5B/6B protection coveralls with hood, shoe covers, gloves, an FFP2 mask, and face shield. Tympanic temperature measurements were taken using a Braun ThermoScan R 7 tympanic thermometer (Braun GmbH, Kronberg, Germany). Duplicate measurements were taken from both left and right tympanic. The highest measurement was taken from the four readings at each time point (44) (45) (46) . Heart rate and blood pressure were measured whilst sitting from the right arm using an OMRON M3 automatic device (Omron, Kyoto, Japan). These were measured hourly throughout the sessions. Urine specific gravity was measured by urine dipstick and urine osmolality with a portable refractometer, calibrated daily (Osmocheck TM , TECIL, Barcelona, Spain). Thermal comfort was measured on a six-point scale from very comfortable (1) to very uncomfortable (6) . Thermal sensation was measured on an eight-point scale from very cold (1) to unbearably hot (8) . Thirst was measured on a five-point scale from not thirsty (1) to very, very thirsty (5). A cognitive battery test was used to assess overall cognitive function. CogniFit General Cognitive Assesment R is a computer-based series of exercises which test multiple cognitive domains and is widely used (47, 48) 1 . The program gives an overall score and specific scores for 26 cognitive areas. All participants completed a familiarization visit with the program prior to attending the study sessions. For the Cool session, participants were given 7.5 ml/kg of ice slurry to drink over 15 min immediately prior to donning PPE (26) . Once full PPE was applied, a commercially available outdoor cooling vest to protect against heat stroke was put on (Sports Cooling Vest, Desertcart.com © ). The cooling vest was a sleeveless, zipped vest with 6 pockets for ice packs, two at the front and four at the back. Ice packs were placed in the vest at the start of the session and replaced hourly (Figure 1 ). Data are reported as mean ± SD, all continuous variables were assessed for normality by distribution and Shapiro-Wilk normality test. Baseline physiology and environmental conditions between control and intervention sessions were assessed using paired t-test for normally distributed variables and Wilcox Signed-Rank test for non-parametric variables. One-way ANOVA was used to determine the change in temperature or heart rate over time in Cool and Control. However, due to violation of model assumptions for repeated measures ANOVA, a multilevel model was used to assess change in tympanic temperature (model 1), heart rate (model 1), and cognitive function (model 2) with intervention as a fixed effect and individuals as random effects. The overall cognitive score and four pre-determined outputs from the cognitive battery test: divided attention, focused attention, and shifting and working memory, were analyzed (model 2). These four outputs were chosen to correlate with the need to multi-task whilst remaining focused as a healthcare worker. Model 1: Cognitive score ∼ β 0 + β 1 * intervention + β 2 * session + β 3 * order + β 4 * sex + β 5 * age + β 6 * T tymp + (1|ind) Session = session 1 or 2 Order = order of intervention by session Sex = male or female Age = age of participant in years at recruitment T tymp = maximum tympanic temperature (1|ind) = participant as a random effect The difference between thermal comfort, sensation and thirst for control and intervention at the end of the session were assessed by proportions and chi-squared. Thermal comfort was redefined as comfortable (very comfortable to just comfortable) and uncomfortable (just uncomfortable to very uncomfortable). Thermal sensation was redefined as not hot (very cold to warm) and hot (hot to unbearably hot). Thirst was redefined as minimal thirst (not thirsty to slightly thirsty) and thirsty (thirsty to very, very thirsty). Sixteen participants were recruited and participated in the first session. Three participants (2 male and 1 female) were unable to attend the second session. One participant (female) was acutely unwell during session two, was subsequently diagnosed with an acute viral infection and removed from the study. Twelve registered and auxiliary nurses, 7 males and 5 females, completed both Control and Cool sessions. Of these, one participant terminated the simulation early during the Control session due to light-headedness and pre-syncope. All participants completed the Cool session. Mean air temperature, relative humidity and wet bulb globe temperature (WBGT) at baseline were 29.3 • C, 69.3% and 26.1 • C, respectively. Average temperature, humidity and WBGT throughout the sessions were 30. Thermal sensation, comfort and thirst all differed significantly between control and intervention (Figure 3) . For thermal comfort 92% (11/12) were uncomfortable in the control vs. 8% (1/12) in the intervention (p < 0.001). For thermal sensation 100% (12/12) of those in the control arm felt hot or above at the end of the session vs. 0% (0/12) in the intervention arm (p < 0.001). For thirst, 83% (10/12) felt thirsty or very thirsty in the control vs. 17% (2/12) in the intervention (p = 0.04). Mean cognitive function scores per session are presented in Table 2 . The first test was the familiarization test and each subsequent test was run after completion of the sessions whilst participants remained in PPE. The standard error of measurement (SEM) indicated there was a learning element to the test where the test completed at the end of session 2 scored higher than the session 1 test (familiarization: session 1 SEM = 19.0%, session 1: session 2 SEM = 17.2%. Multilevel modeling did not demonstrate any difference in overall cognitive function by Control vs. Cool. Table 3 gives details of the models for all pre-specified cognitive domains tested. Intervention had no impact on any domains. Plots of all multilevel model residuals were examined for deviation from linear form by Pearson correlation. Constance of variance of residuals was also examined and normality of residuals. All model assumptions in all models were met according to these tests. This study demonstrated that a combination of pre-and per-cooling reduced thermal strain in HCW wearing PPE, and can improve discomfort from thermal sensation, comfort and thirst. We did not show any impact on cognitive function. Several recent studies have explored personal cooling options whilst wearing PPE and although our findings are similar to these, this study is novel in that it evaluated a mixed-method cooling approach (using both internal and external, and pre and per-cooling) and the effect of external cooling was prolonged by replacing ice-packs. The study by De Korte et al. explored 21 • C phase change vests under PPE and significantly improved thermal comfort and sensation, although it had no impact on thermal strain (49) . However, the transferability of this vest for cooling in the tropics is questionable due to differences in ambient conditions and potential resource limitation. Another study of PPE used for Ebola treatment, based in a heat-chamber, found a reduction in heat strain with several different types of cooling vest (40) . Although this study was performed in similar ambient conditions, the PPE requirements for Ebola are different to COVID and the exposure was only for 1 h and so not directly transferrable to current practice in treating COVID. Focusing on the physiological changes in the study, we did not see the rise in temperatures described in two other studies of PPE use in West Africa (50, 51) . These studies were performed during the Ebola outbreak and found HCW in PPE had an average core temperature rise to 38 • C and in 4/25 individuals exceeded 38.5 • C after 1 h in PPE (50) . This may in part be due to the characteristics of the PPE requirements for Ebola vs. COVID, since external conditions were similar, but may in part be due to heat acclimation. Our study's participants were West African nationals, who had been residing in the region for at least 6 months prior to the study and therefore had likely acclimated (a series of phenotypic changes resulting in physiological alterations that act to protect against heat stress) and the other studies participants were French and American nationals. Notably, mean resting tympanic temperature was lower in the participants of the present study. This may also help to explain why there was no impact of wearing PPE on cognitive function amongst HCW. The literature on the impact of heat stress on cognitive function suggests a critical threshold of thermal strain on cognitive function, below which there is no impact (31) . The HCW in our study did not cross this critical threshold, potentially explaining the lack of impact on cognitive function. This is reassuring for patient care, although our data was measured on a single day and it is unclear whether cumulative thermal strain over successive days wearing PPE would result in a diminished cognitive function. All participants in the study were able to perform emergency medical procedures with no evidence of compromise to the PPE, condensation or droplet spread caused by the per-cooling vest. The practicalities of enacting this intervention will depend on the facilities available. In the MRCG hospital, we have completed staff sensitization and awareness sessions, provided access to cold/iced drinks in the hospital staff common room and located a chest freezer, the ice-packs and ice-vests in the COVID-zone. This will enable staff to use the ice-vests in a contaminated space and keep them in that space, avoiding the risk and inconvenience of repeated decontamination. There are several limitations to the study. There were four participants who were unable to complete both sessions, reducing the sample size. The sample size calculation was based on previous studies of heat alleviation in PPE, and so although we did not meet the target of sixteen, twelve was within our minimal sample required. At baseline, the tympanic temperature of the Cool group was 0.2C higher than the Control and although this is likely due to chance and was not a statistically significant difference, it may have impacted on the findings. Additionally, although the temperature and humidity remained relatively constant during the session, it did vary more than if the study had been run in a heat-chamber, but there was no significant difference between Cool and Control sessions. The advantage of the study being run on a hospital ward was that although the ambient conditions were not controlled, they were exactly what HCWs experience and so directly generalizable. The gold standard for core temperature is rectal or esophageal temperature. These were not practical whilst in PPE and cost constraints prevented the use of a telemetry pill. Core temperature may thus have under-recorded, however we monitored both the change in temperature as well as the absolute temperature to reduce the impact of this limitation on data interpretation. Additionally, most physiological studies use continuous heart rate monitoring, which was not available in this study. The cognitive battery test used was designed and validated in America and assumes a degree of computer or tablet literacy resulting in certain language and technological aptitude barriers. Finally, the study used simulation to model real-life ward experience, to ensure standardization, but in reality, clinical work can be highly variable, and this may not have been captured. Additionally, shift durations vary dramatically depending on staffing, clinical workload and availability of PPE and therefore the applicability of these solutions will be locally dependent. However, direct comparison of Control and Cool would have been very challenging in a real-world setting. Pre-and per-cooling using internal and external cooling modalities reduced thermal strain in HCW in PPE for a prolonged duration, dramatically improved thermal sensation, comfort and thirst and is safe to implement, with no detriment on ability to perform medical tasks or contamination risk by condensation. The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation. The studies involving human participants were reviewed and approved by Gambia Government/MRC joint ethics committee and the London School of Hygiene and Tropical Medicine Ethics Advisory Board. The patients/participants provided their written informed consent to participate in this study. Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article. AB conceived, designed, implemented, and completed first draft of the manuscript. BN advised on design, facilitated implementation, and edited manuscript. TS and JB facilitated implementation and edited manuscript. RP-T, KF, and AP advised on design and edited manuscript. NM advised on conception and design and edited manuscript. All authors contributed to the article and approved the submitted version. COVID-19 Weekly Epidemiological Update. World Health Organization (2021) The COVID-19 pandemic, personal protective equipment and respirator: a narrative review Personal protective equipment and COVID-19 Rational Use of Personal Protective Equipement for Coronavirus Disear (COVID-19) and Considerations During Severe Shortages. World Health Organization Occupational heat stress and practical cooling solutions for healthcare and industry workers during the COVID-19 pandemic ACGIH Threshold Limit Values (TLVs) and Biological Expsoure Indices (BEIs). 1330 Kemper Meadow Drive NIOSH Criteria for a Recommended Standard: Occupational Exposure to Heat and Hot Environments. U.S. Department of Health and Human Services, Centres for Disease Control and Prevention Do the threshold limit values for work in hot conditions adequetaley protect workers? Thermal exposure and heat illness symptoms among workers in mara gold mine Occupational heat stress, thermal comfort, and cognitive performance in the OR: an integrative review The ventilation of multiple-bed hospital wards in the tropics: a review Module 1B: Ventilation and Exhausted Air Treatment as IPC Measures Within a COVID-19 Context. World Health Organisation Impact of personal protective equipment on clinical output and perceived exertion Available online at The effects of wearing respirators on human fine motor, visual, and cognitive performance Personal protective equipment and intensive care unit healthcare worker safety in the COVID-19 era (PPE-SAFE): an international survey An evaluation of personal cooling systems for reducing thermal strain whilst working in chemical/biological protective clothing Cooling interventions for athletes: an overview of effectiveness, physiological mechanisms, and practical considerations Active versus passive cooling during work in warm environments while wearing firefighting protective clothing Ice cooling vest on tolerance for exercise under uncompensable heat stress Exertional thermal strain, protective clothing and auxiliary cooling in dry heat: evidence for physiological but not cognitive impairment Reducing heat stress under thermal insulation in protective clothing: microclimate cooling by a "physiological The impacts of sun exposure on worker physiology and cognition: multicountry evidence and interventions Occupational heat stress: multi-country observations and interventions Ice slurry ingestion increases core temperature capacity and running time in the heat Thermoregulatory responses to ice-slush beverage ingestion and exercise in the heat Cooling during exercise enhances performances, but the cooled body areas matter: a systematic review with meta-analyses Enhanced decision making and working memory during exercise in the heat with crushed ice ingestion Effects of precooling on thermoregulation during subsequent exercise Literature review: cognitive effects of thermal strain Cognitive functioning and heat strain: performance responses and protective strategies An investigation of heat stress effects on time-sharing performance Task performance in heat: a review The impact of respiratory protective equipment on difficult airway management: a randomised, crossover, simulation study Respiratory protection during simulated emergency pediatric life support: a randomized, controlled, crossover study The impact of heat stress on operative performance and cognitive function during simulated laparoscopic operative tasks Limiting factors for wearing personal protective equipment (PPE) in a health care environment evaluated in a randomised study World Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects Physiological evaluation of cooling devices in conjunction with personal protective ensembles recommended for use in West Africa Basic Emergency Care: Approach to the Acutely Ill and Injured Advanced Adult Life Support: Teaching Material Energy expenditure performing hands-only cardiopulmonary resuscitation during average emergency response times Tympanic temperature is a core temperature in humans Reexamination of tympanic membrane temperature as a core temperature Re-visiting the tympanic membrane vicinity as core body temperature measurement site Computer-based, personalized cognitive training versus classical computer games: a randomized double-blind prospective trial of cognitive stimulation Chronic insomnia and cognitive functioning among older adults Cooling vests alleviate perceptual heat strain perceived by COVID-19 nurses Moderate thermal strain in healthcare workers wearing personal protective equipment during treatment and care activities in the context of the 2014 Ebola virus disease outbreak Physiological evaluation of personal protective ensembles recommended for use in West Africa We would like to thank all CSD staff who participated in the study with such willingness and enthusiasm and wore PPE on days when they could have had a rest from it. The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.Publisher's Note: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.Copyright © 2021 Bonell, Nadjm, Samateh, Badjie, Perry-Thomas, Forrest, Prentice and Maxwell. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.