key: cord-0989799-dbbfa6z6 authors: Hanson, Kimberly E; Caliendo, Angela M; Arias, Cesar A; Englund, Janet A; Hayden, Mary K; Lee, Mark J; Loeb, Mark; Patel, Robin; Altayar, Osama; El Alayli, Abdallah; Sultan, Shahnaz; Falck-Ytter, Yngve; Lavergne, Valéry; Morgan, Rebecca L; Murad, M Hassan; Bhimraj, Adarsh; Mustafa, Reem A title: Infectious Diseases Society of America Guidelines on the Diagnosis of COVID-19:Serologic Testing date: 2020-09-12 journal: Clin Infect Dis DOI: 10.1093/cid/ciaa1343 sha: 58967562370229abe8d1db22e3b4146a843a4814 doc_id: 989799 cord_uid: dbbfa6z6 BACKGROUND: The availability of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serologic testing has rapidly increased. Current assays use a variety of technologies, measure different classes of immunoglobulin or immunoglobulin combinations and detect antibodies directed against different portions of the virus. The overall accuracy of these tests, however, has not been well-defined. The Infectious Diseases Society of America (IDSA) convened an expert panel to perform a systematic review of the coronavirus disease 2019 (COVID-19) serology literature and construct best practice guidance related to SARS-CoV-2 serologic testing. This guideline is the fourth in a series of rapid, frequently updated COVID-19 guidelines developed by IDSA. OBJECTIVE: IDSA’s goal was to develop evidence-based recommendations that assist clinicians, clinical laboratories, patients and policymakers in decisions related to the optimal use of SARS-CoV-2 serologic tests in a variety of settings. We also highlight important unmet research needs pertaining to the use of anti-SARS-CoV-2 antibody tests for diagnosis, public health surveillance, vaccine development and the selection of convalescent plasma donors. METHODS: A multidisciplinary panel of infectious diseases clinicians, clinical microbiologists and experts in systematic literature review identified and prioritized clinical questions related to the use of SARS-CoV-2 serologic tests. Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology was used to assess the certainty of evidence and make testing recommendations. RESULTS: The panel agreed on eight diagnostic recommendations. CONCLUSIONS: Information on the clinical performance and utility of SARS-CoV-2 serologic tests are rapidly emerging. Based on available evidence, detection of anti-SARS-CoV-2 antibodies may be useful for confirming the presence of current or past infection in selected situations. The panel identified three potential indications for serologic testing including: 1) evaluation of patients with a high clinical suspicion for COVID-19 when molecular diagnostic testing is negative and at least two weeks have passed since symptom onset; 2) assessment of multisystem inflammatory syndrome in children; and 3) for conducting serosurveillance studies. The certainty of available evidence supporting the use of serology for either diagnosis or epidemiology was, however, graded as very low to moderate. A c c e p t e d M a n u s c r i p t Serologic tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are now widely available. Unlike nucleic acid amplification tests (NAAT) which detect viral RNA, antibody-based assays measure the host's humoral immune response to current or past infection. Anti-SARS-CoV-2 antibodies typically become detectable more than two weeks after the onset of symptoms (Figure 1) . As a result, SARS-CoV-2 serology lacks sufficient sensitivity to confidently exclude the diagnosis of coronavirus disease 2019 (COVID-19) when antibodies are not detected in the acute phase of illness. NAAT remains the diagnostic modality of choice for acute infection. Antibody testing, however, may be useful as an adjunct to NAAT at later time points following infection. In general, IgM tests tend to have lower sensitivity to detect past infection than IgG or total antibody tests. Assays designed to detect and differentiate IgM and IgG in combination, where the detection of either IgM or IgG is used to define a positive test result, and IgA tests tend to have lower specificity to detect past infection compared to IgG only or total antibody tests. Test specificity is especially important for large serosurveillance studies when the prevalence of prior infection in the community is expected to be low. To be of value, anti-SARS-CoV-2 antibody tests are required to have high clinical sensitivity and specificity (i.e., 99.5%). In addition to use in epidemiologic studies, the panel identified two clinical scenarios where antibody testing was felt to have potential utility for diagnosis. Serologic testing may be helpful in the evaluation of individual patients with a high clinical suspicion for COVID-19 when the results of molecular diagnostic testing are repeatedly negative or such testing was not performed. The sensitivity and specificity of IgG and total antibody is optimal three to four weeks after the onset of symptoms. At the current time, little data exists in the fifth week postsymptom onset to judge serologic test performance at later periods after infection. Detection of anti-SARS-CoV-2 antibodies is also useful for assessments of suspected multisystem inflammatory syndrome in children. For symptomatic patients, optimal serology result interpretation requires careful determination of the timing of testing relative to symptom onset A c c e p t e d M a n u s c r i p t combined with assessments of disease severity. Based on the available evidence at this time, serologic tests should not be used to determine immunity or risk of re-infection. Thus, anti-SARS-CoV-2 antibody detection cannot inform decisions to discontinue physical distancing or lessen the use of personal protective equipment. Summarized below are specific recommendations and comments related to the use of SARS-CoV-2 serologic testing in clinical practice and public health. A detailed description of background, methods, evidence summary and rationales that support each recommendation can be found online in the full text.  Remark -When serology is being considered as an adjunct to NAAT for diagnosis, testing three to four weeks post-symptom onset maximizes the sensitivity and specificity to detect past infection.  Remark -Serosurveillance studies should use assays with high specificity (i.e., 99.5%), especially when the prevalence of SARS-CoV-2 in the community is expected to be low.  Remark -When serology is being considered as an adjunct to NAAT for diagnosis, testing three to four weeks post-symptom onset maximizes the sensitivity and specificity to detect past infection. A c c e p t e d M a n u s c r i p t Background Since its emergence in December 2019, the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused over 21 million known infections and nearly 770,000 deaths worldwide [1] . Definitive diagnosis of coronavirus disease , the illness caused by SARS-CoV-2 infection, relies on the direct detection of virus-specific RNA or virusspecific glycoprotein antigens in respiratory tract specimens. Serologic tests that detect the host antibody response to SARS-CoV-2 may also help to confirm the presence of current or past infection using blood samples. Coronavirus genomes encode four major structural proteins including spike (S), envelope (E), membrane (M) and nucleocapsid (N). Both the S and N proteins of SARS-CoV-2 have been shown to be immunogenic in humans and current serologic tests target antibodies directed against these antigens [2] . The S protein is the most exposed viral protein and is responsible for viral attachment and entry into the host cell via binding to the angiotensinconverting enzyme 2 (ACE-2) receptor [3] . The S protein is comprised of an N-terminal S1 subunit, involved in virus-receptor binding, and a C-terminal S2 subunit that is involved in fusion to the host cell membrane. The S1 subunit is further divided into the N terminal domain (NTD) and a receptor binding domain (RBD). There has been particular focus on the SARS-CoV-2 RBD for vaccine development and targeted antibody therapies because neutralizing antibodies against this region effectively block viral entry [4, 5] . The N protein is an RNAbinding protein that is abundantly expressed during infection and plays an important role in RNA transcription and replication [6] . There are two general types of antibodies, neutralizing antibodies (nAbs) and nonneutralizing (also known as binding antibodies) [7] . Neutralization is defined as the loss of infectivity that occurs when a nAb binds to a viral particle. Virus-specific or vaccine-induced nAbs can play a crucial role in controlling viral infection, but definitive data is lacking to know whether individuals with detectable anti-SARS-CoV-2 nAbs are protected against reinfection. In comparison, binding antibodies are characterized by their inability to prevent viral infection of A c c e p t e d M a n u s c r i p t permissive cells. Regardless of their function, both types of virus-specific antibodies are potentially useful as diagnostic indicators of current or past infection. Commercially available anti-SARS-CoV-2 antibody tests use different technologies to qualitatively measure single immunoglobulin classes (IgM, IgG or IgA) or total antibody, but do not differentiate nAbs from binding antibodies. IgM antibodies directed against microorganisms are typically produced first after infection and are used as a measure of recent infection. IgG antibodies generally develop later after IgM and remains elevated for months to years after infection. Although IgM antibodies can be detected within the first two weeks of symptoms in some patients, SARS-CoV-2 infection appears unusual in that IgM and IgG more commonly rise together, more than two weeks after the onset of symptoms [8] . Secretory IgA is important for mucosal immunity. IgA can also be detected systemically in certain types of infection including SARS-CoV-2, but comparatively little is known about the kinetics of IgA in blood. The components of "total antibody" presumably include IgM and IgG and theoretically other antigenspecific immunoglobulins as well. Given that the majority of the population has previously been exposed to seasonal human coronaviruses (HCoV), and these viruses may share similar structure with SARS-CoV-2, an essential part of serologic test development and validation is to assure that the anti-SARS-CoV-2 antibodies detected by a given assay do not cross react with other coronaviruses (e.g., HCoV-229E, HCoV-NL63, HCoV-OC43 or HCoV-HKU1). Specificity studies typically involve analyzing archived sera obtained before the identification of COVID-19 as a clinical entity, as well as assessing for potential interfering substances such as auto-antibodies or heterophile antibodies. The most common clinical diagnostic platforms utilized for SARS-CoV-2 include lateral flow (LF) devices, enzyme linked immunosorbent assays (ELISA) and chemiluminescent immunoassays (CIA). Lateral flow assays typically require a drop of blood (or serum or plasma) applied to a test strip, with results read in approximately 15-30 minutes. These devices are suitable for point-of-care testing and have potential to be deployed in the field as a part of large A c c e p t e d M a n u s c r i p t serological surveys. ELISA comes in a variety of different formats. Typically, a bound antigenantibody complex is detected using a type-specific secondary antibody linked to a substrate that generates a colorimetric or fluorescent signal. CIA methods are similar to ELISA but use chemical probes that emit light instead of enzymatic substrates. Both ELISA and CIA are clinical laboratory-based methods amendable to high throughput testing using serum, plasma or potentially dried blood spots. At this time, neutralization assays are mainly used in research settings or offered as laboratory developed tests by reference laboratories. In the United States, the Food and Drug Administration (FDA) currently requires Emergency Use Authorization (EUA) to market a SARS-CoV-2 antibody test. This means that commercial manufacturers and clinical laboratories with laboratory-developed tests must submit performance data to the FDA for review. Early in the pandemic, however, official EUA review was voluntary. Test developers were only expected to internally validate their tests and notify the FDA of their intent to market. As a result, the market was flooded with poorly performing assays. In response the FDA subsequently issued a "removed" test list that includes tests where significant performance problems were identified, assays for which official EUA review was not appropriately submitted or assays voluntarily withdrawn by the developer. Many different serologic tests for SARS-CoV-2 have become commercially available in a short amount of time. The incredible speed of development has significantly outpaced rigorous assessments of test performance. Therefore, IDSA convened an expert panel to systematically review the available serologic literature, compare pooled estimates of test accuracy and make evidence-based recommendations for informed use in clinical practice. This guideline was developed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach for evidence assessment. In addition, given the need for a rapid response to an urgent public health crisis, the methodological approach was modified according to the GIN/McMaster checklist for the development of rapid A c c e p t e d M a n u s c r i p t recommendations [9] . To assess the positive and negative predictive value of serologic testing we considered prevalence 1% to represent communities with low levels of circulating SARS-CoV-2 infections, 10% [10] [11] [12] which is typically seen in "hot spots" and 40% which is typically seen in patients meeting the clinical definition for COVID-19 who were hospitalized or in the investigation of outbreaks in congregate settings or factories [13, 14] . The panel was composed of clinicians and clinical microbiologists who are members of the IDSA, the American Society for Microbiology (ASM), the Society for Healthcare Epidemiology of America (SHEA), and the Pediatric Infectious Diseases Society (PIDS). They represented the disciplines of infectious diseases, pediatrics, clinical microbiology, hepatology, nephrology and gastroenterology. The Evidence Foundation provided technical support and guideline methodologists for the development of this guideline. The conflict of interest (COI) review group included two representatives from IDSA who were responsible for reviewing, evaluating and approving all disclosures. All members of the expert panel complied with the COI process for reviewing and managing conflicts of interest, which required disclosure of any financial, intellectual, or other interest that might be construed as constituting an actual, potential, or apparent conflict, regardless of relevancy to the guideline topic. The assessment of disclosed relationships for possible COI was based on the relative weight of the financial relationship (i.e., monetary amount) and the relevance of the relationship (i.e., the degree to which an association might reasonably be interpreted by an independent observer as related to the topic or recommendation of consideration). The COI review group ensured that the majority of the panel and chair was without potential relevant (related to the topic) conflicts. The chair and all members of the technical team were determined to have no COIs relevant to the guidelines. A c c e p t e d M a n u s c r i p t Clinical questions were developed into a PICO format (Population, Intervention, Comparison, Outcomes) [15] prior to the first panel meeting. Panel members prioritized questions with available evidence that met the minimum acceptable criteria (i.e., diagnostic test accuracy reported on at least a case-series design, case reports were excluded) (Figure s1 ). Panel members prioritized patient-important outcomes such as the role of serologic testing in diagnosing acute or recent infections, the role of point of care serologic tests and the role of serologic tests in the evaluation of pediatric patients with inflammatory multisystem syndromes. The National Institute of Health and Care Excellence (NICE) and the Centers for Disease Control and Prevention (CDC) highly sensitive search was reviewed by the methodologists in consultation with an experienced information specialist and was determined to have high sensitivity. Terms identified in the PICO questions and the term "COVID" were added to the search strategy. We searched Ovid Medline and Embase from 2019 through June 19, 2020. We also performed horizon scans periodically during the evidence assessment and recommendation process to locate additional grey literature and manuscript preprints from LitCovid, medRxiv/bioRxiv, and SSRN. Reference lists and literature suggested by the panelists were reviewed for inclusion as well. We also manually searched the manufacturers' package inserts of the serologic tests that received EUA by the FDA. Two independent reviewers screened the titles and abstracts of the references identified by the search strategy and then reviewed the full texts of the studies under consideration for inclusion. Disagreements were resolved by discussion to reach consensus in consultation with a A c c e p t e d M a n u s c r i p t third reviewer when needed. Studies were reviewed if they reported data on the diagnostic test accuracy of anti-SARS-CoV-2 IgM, IgG, IgA, and/or total antibody tests compared to NAAT as the reference standard. We only included studies that evaluated one of the three most commonly used serology platforms (i.e., LF, ELISA and CIA). To be included, cohort, cross-sectional and case-control studies had to include at least 30 samples, describe the time of testing relative to symptom onset and provided information on the reference standard for comparison. A sample size of 30 specimens was set to mirror the minimal numbers of specimens required by the FDA for EUA, but assays were included in our review regardless of FDA authorization status. Assays that required both IgM and IgG to be detected to define a positive result were excluded. We also excluded studies that reported sensitivity only, specificity only and studies that did not provide enough information to extract the true positives, true negatives, false positives, and false negatives. The data extraction was completed by two independent reviewers in duplicate. Disagreements were resolved by reaching consensus and consulting with an expert clinician scientist member of the panel. We extracted baseline characteristics (authors, publication year, country, study design, inclusion criteria, age, gender), index test information (timing from onset of symptoms, sample type, target antigen, platform, immunoglobulin class, FDA EUA status, and European Economic Area CE marking status), reference test (name of test, sample type), and diagnostic test accuracy raw data (true and false positives and negatives). We used the bivariate random effects model to pool the sensitivity and specificity using the logit transformation, when there were enough studies [16] . When the number of studies did not allow the use of the bivariate model, we pooled the sensitivity and specificity separately using the random effects generalized linear mixed models [17, 18] . To evaluate the between study heterogeneity, we examined the forest plots for each pooled estimate rather than relying on the I 2 statistic which does not take into account the variability resulting from different A c c e p t e d M a n u s c r i p t positivity thresholds. We evaluated the graphs visually for factors that could explain the heterogeneity including the platform used, FDA EUA or European Conformity (CE) mark statuses, and target antigen. To evaluate the effects of our decision to exclude studies that included fewer than 30 samples, we performed sensitivity analyses by including all the studies that reported both sensitivity and specificity. We also performed sensitivity analyses by excluding studies that included less than 100 samples in the specificity group and studies that evaluated tests that were removed from FDA EUA list. The analyses were performed using the packages mada 0.5.10 and meta 4.11.0 in R 3.6.3 [19] [20] [21] . We used the Quality Assessment of Diagnostic Studies (QUADAS)-2 revised tool to assess the risk of bias in the included studies [22] . We used the GRADE framework to assess the overall certainty by evaluating the body of evidence for each outcome on the following domains: risk of bias, imprecision, inconsistency, indirectness, and publication bias [23, 24] . We developed GRADE summary of findings tables using the GRADEpro Guideline Development Tool [25] . The panel considered the core elements of GRADE evidence in the decision process, including certainty of evidence and balance between desirable and undesirable effects. Additional domains were acknowledged where applicable (e.g., feasibility, resource use, acceptability). For all recommendations, the expert panelists reached consensus. Voting rules were agreed on prior to the panel meeting for situations when consensus could not be reached. As per GRADE methodology, recommendations were labeled as "strong" or "conditional." The words "we recommend" indicate strong recommendations and "we suggest" indicate conditional recommendations. Figure 2 provides the suggested interpretation of A c c e p t e d M a n u s c r i p t strong and weak recommendations for patients, clinicians, and healthcare policymakers. For recommendations where the comparators are not formally stated, the comparison of interest was implicitly referred to as "not using the test." Some recommendations acknowledge a current "knowledge gap" and aim at avoiding premature favorable recommendations for test use and to avoid encouraging the rapid diffusion of potentially non-useful tests. The draft guideline underwent a rapid review for approval by IDSA Board of Directors Executive Committee external to the guideline development panel. The guidelines was reviewed and endorsed by ASM, PIDS and SHEA. The IDSA Board of Directors Executive Committee reviewed and approved the guideline prior to dissemination. Regular, frequent screening of the literature will take place to determine the need for revisions based on the likelihood that any new data will have an impact on the recommendations. If necessary, the entire expert panel will be reconvened to discuss potential changes. A c c e p t e d M a n u s c r i p t M a n u s c r i p t Using our search strategy, we identified 24 [48, 49] . Included studies reporting on three different testing methodologies, namely LF assays, ELISA, and CIA. Studies also assessed different antibody classes including IgM alone, IgG alone, IgA alone or total antibody, depending on the kit used. For the assays that detected and differentiated IgM and IgG in the same platform, results interpretation included assessments "IgM or IgG" approaches where the presence of one of them qualified as a positive test. The total number of samples included ranged from 91 to 2,708 and 721 to 11,887, for the sensitivity and specificity analyses, respectively. The pooled sensitivity at week one after symptom onset ranged from 0.23 to 0.63 and at week two ranged from 0.68 to 0.96, while the pooled specificity ranged from 0.96 to 1 (Tables 1a-1e ). The quality of evidence that informed sensitivity determinations ranged from very low to low, while specificity was low to moderate. Quality was rated down for serious risk of bias (case control study design), imprecision A c c e p t e d M a n u s c r i p t (assuming the upper and lower limits of the confidence interval would lead to different decisions) and unexplained inconsistency. The panel placed a high value on reducing false negative results. During the first two weeks following infection the sensitivity for all serology tests, regardless of the platform and immunoglobulin detected, was inadequate to avoid a large number of false negative results. The concern with low sensitivity is that individuals who test negative would be classified as uninfected, when, in fact, they had been infected but have not fully developed an antibody response. Likewise, when assessing the seropositivity rate of a population, tests with poor sensitivity will provide an underestimation of the percentage of the population that is or was A c c e p t e d M a n u s c r i p t IgM antibody responses typically occur earlier after the onset of infection compared to IgG antibody responses in most microbial infections. In contrast, with SARS-CoV-2 infection, there does not appear to be a significant difference in the sensitivity of tests that detect IgM antibody compared to those that detect IgG antibodies in the first weeks following infection. At one week after onset of symptoms, the pooled sensitivity for IgM tests was 33% compared to 23% for IgG tests, and at two weeks post onset of symptoms, the pooled sensitivity of IgM tests was 73% compared to 68% for IgG tests (Tables 1a-1b) . The specificity for IgM tests was slightly lower (98%) compared to IgG tests (99%), but the confidence intervals overlapped. Based on available evidence, there does not appear to be a substantially increased diagnostic accuracy when using IgM tests compared to IgG tests early in the course of illness. IgA tests, while more sensitive than IgG and IgM tests within the first two weeks of symptom onset, have a lower specificity (96%) and so their use would greatly increase false positive results. In a low prevalence population for example (i.e., 1%), 87% of the positive IgA results would be false positives (Table 1c) ; when the prevalence is 10% (for example in "hot spots"), 39% of the positive results would be false positives. Of note, the number of studies evaluating IgA are much fewer than for IgM and IgG. There are LF assays that detect and distinguish between IgM and IgG. These platforms require either IgM or IgG to be detected for a positive result (referred to as IgM or IgG tests). This "either/or" interpretation increases test sensitivity, but also slightly reduces specificity from 98% to 97%. Overall, IgM or IgG detection does not improve the diagnostic accuracy relative to detection of either antibody class alone. In contrast, detection of total antibody within the first two weeks after infection does increase sensitivity while maintaining a high specificity. These differences may be due to the fact that IgM or IgG tests tend to be LF assays, which show more inconsistency than total antibody detected using ELISA or CIA (Figure s3 -Forest Plots). Total antibody platforms may have the highest diagnostic utility during the early A c c e p t e d M a n u s c r i p t time period. However, the number of studies evaluating total antibody tests was substantially lower than the number of studies assessing IgM or IgG tests. There is substantial variability in the performance of tests and different testing A c c e p t e d M a n u s c r i p t Typically seen in general population in areas that are not hotspots b. Typically seen in general population in high risk populations c. Typically seen in general population in exposed and nursing homes d. The case-control design leads to a serious risk of bias e. Unexplained inconsistency observed with considerably variable sensitivity. Sensitivity Ranges: C1: 0.06-0.62, C2: 0.33-1.00 M a n u s c r i p t 10 (10 to 10) 9 (9 to 9) 6 (6 to 6) Typically seen in general population in areas that are not hotspots b. Typically seen in general population in high risk populations c. Typically seen in general population in exposed and nursing homes d. The case-control design leads to a serious risk of bias e. Unexplained inconsistency observed with considerably variable sensitivity. Sensitivity Ranges: C1: 0.00,0.69, C2: 0.27-0.91 M a n u s c r i p t a. Typically seen in general population in areas that are not hotspots b. Typically seen in general population in high risk populations c. Typically seen in general population in exposed and nursing homes d. The case-control design leads to a serious risk of bias e. Considering the Upper vs Lower limits of the sensitivity's confidence interval would lead to different clinical decisions. M a n u s c r i p t 0 (0 to 10) 0 (0 to 9) 0 (0 to 6) Typically seen in general population in areas that are not hotspots b. Typically seen in general population in high risk populations c. Typically seen in general population in exposed and nursing homes d. The case-control design leads to a serious risk of bias e. Unexplained inconsistency observed with considerably variable sensitivity. M a n u s c r i p t a. Typically seen in general population in areas that are not hotspots b. Typically seen in general population in high risk populations c. Typically seen in general population in exposed and nursing homes d. The case-control design leads to a serious risk of bias e. Unexplained  Remark -When serology is being considered as an adjunct to NAAT for diagnosis, testing three to four weeks post-symptom onset maximizes the sensitivity and specificity to detect past infection.  Remark -Serosurveillance studies should use assays with high specificity (i.e., 99.5%), especially when the prevalence of SARS-CoV-2 in the community is expected to be low. A c c e p t e d M a n u s c r i p t The same studies and package inserts [50-56] that were used to inform recommendation 1 were examined to assess test performance at weeks three, four, and five following the onset of COVID-19 signs or symptoms ( Table s2) Tables 2a-2e ). The quality of evidence that informed sensitivity analyses ranged from very low to moderate; the quality of evidence that informed specificity was also low to moderate. There was a serious risk of bias (case control study design), imprecision (assuming the upper and lower limits of the confidence interval would lead to different decisions) and unexplained inconsistency. The panel placed a high value on reducing false positive test results and determining the optimal timing of testing to confidently assess previous infection. Detection of IgG or total antibody at three to four weeks after the onset of symptoms provides the highest sensitivity, and thus the lowest rate of false negative results, compared to other immunoglobulin classes or earlier time points. IgG or total antibody tests also provide high specificity, and thus, reduce the rate of false positive results relative to other antibody types. The specificity of IgM tests in the three to four weeks post-symptom onset timeframe was equivalent to IgG tests. However, in contrast to other viral infections where IgM tests show high sensitivity shortly after onset of symptoms compared to IgG, IgM sensitivity against SARS-CoV-2 is relatively low early on and there is no significant increase over time as is seen with IgG or total antibody (Table 2a, Table 2b, Table 2d ). The use of the IgM tests alone would result in increased A c c e p t e d M a n u s c r i p t false negative rates compared to IgG or total antibody tests. Given these tradeoffs, the panel suggested neither for nor against the use of IgM tests to assess previous infection. considered a positive result, all suffer from lower specificity compared to tests involving IgG or total antibody targets, leading to increased false positive rates. These tests would falsely increase seroprevalence and potentially mislead public health officials, policymakers, and the general public. In addition, false positive results might detract from pursuing alternative diagnoses in symptomatic patients. Therefore, the panel suggested against the use of any of these tests at this time. The predictive value of diagnostic test results depends on the performance characteristics of the test (i.e., sensitivity and specificity) and on the prevalence of the disease in the population tested. In general, the higher the prevalence, the higher the false negative rate, and the lower the prevalence, the higher the false positive rate. To illustrate the importance of this concept in interpreting antibody test results, the panel calculated the number of false positive and false negative results in populations with 1% and 10% SARS-CoV-2 seroprevalence, using pooled sensitivity and specificity from the data review. The 1% prevalence was chosen to represent a population with few prior cases of COVID-19, and the 10% prevalence was chosen to represent a COVID-19 "hot spot" population. As can be seen in Figure 3 , even tests with seemingly high sensitivity and specificity can yield a large proportion of erroneous results at the extremes of prevalence. In this example, in a population with a 1% prevalence of SARS-CoV-2, a test with 96% sensitivity and 99% specificity would generate an equal number of true positive and false positive results. Limited data are available on duration of the IgG response, but in the studies we reviewed it appeared to be sustained for at least three to five weeks. The panel recommends testing for IgG or A c c e p t e d M a n u s c r i p t total antibody at three to four weeks because there are limited data on IgG or total antibody responses five weeks or longer after onset of symptoms. The IgM response begins to decrease by week four after symptom onset, such that IgM appears to be less sensitive over time than IgG for detection of recent past infection with SARS-CoV-2. Overall, the panel identified substantial variability in sensitivity and specificity among tests (Figure s3 -Forest Plots) . While inconsistent performance characteristics were observed across the three test methodologies included in the data summary, more inconsistency was seen for LF methods than for CIA or ELISA assays. Similar to the acute timeframe, IgM assays showed more variable performance than did IgG assays at later time posts after infection. Interestingly, the specific antigen targeted in the antibody test (e.g., S protein or N protein) did not appear to impact test performance, although some studies did not report the antigen that was targeted. Sensitivity and specificity differences between available assays require that clinicians understand the performance characteristics of the particular test that is used. A general sense of prevalence (or pre-test probability) in the population being tested is also helpful to ensure accurate interpretation of test results. While NAAT remains the recommended approach for diagnosis of COVID-19, detection of IgG or total antibody directed against SARS-CoV-2 at three to four weeks after symptom onset may be useful for determining past infection in selected clinical situations (see recommendations 6 and 7). IgG alone is typically used for determining seroprevalence, but information on the duration of a detectable antibody response beyond four weeks is limited. It is important to realize that the presence of SARS-CoV-2 IgG or total antibody cannot be Larger studies of well-characterized and varied populations will be needed to begin to answer these questions. Availability of a reference standard for seropositivity (e.g., presence of neutralizing antibody) would also be valuable. A c c e p t e d M a n u s c r i p t M a n u s c r i p t 10 (10 to 10) 9 (9 to 9) 6 (6 to 6) M a n u s c r i p t M a n u s c r i p t 0 (0 to 10) 0 (0 to 9) 0 (0 to 6) Typically seen in general population in areas that are not hotspots b. Typically seen in general population in high risk populations c. Typically seen in general population in exposed and nursing homes d. The case-control design leads to a serious risk of bias e. Unexplained inconsistency observed with considerably variable sensitivity. Sensitivity Ranges: C3: 0.78-1.00, C4: 0.88-0.94, C5: 0.95 M a n u s c r i p t M a n u s c r i p t Footnote: This graph models the predictive value of a theoretic serologic test with 96% sensitivity and 99% specificity across a spectrum of prevalence. When the true prevalence of SARS-CoV-2 infection in a population is 1%, the positive predictive value of the test is only 49%. In other words, there is a 49% chance (close to a flip of the coin) that individuals with a positive screening test truly have the disease. As the prevalence increases, so does the predictive value. In contrast, when the prevalence of infection is 1%, the negative predictive value high (i.e., there is close to 100% probably the disease is truly absent when the result of the test is negative). A c c e p t e d M a n u s c r i p t  Remark -When serology is being considered as an adjunct to NAAT for diagnosis, testing three to four weeks post-symptom onset maximizes the sensitivity and specificity to detect past infection. In addition to the evidence that informed recommendations 1 through 5, we identified seven studies that compared the diagnostic test accuracy of serologic tests among patients with high clinical suspicion for COVID-19 and either negative NAAT throughout the course of their illness [57] [58] [59] [60] [61] , or negative NAAT on repeat testing after initial positive tests [62, 63] . The seven case studies showed an increase in diagnostic yield when antibodies were added to NAAT after 14 days of symptom onset. In addition, IgG identified a higher number of positive cases compared to IgM (Table s3) . It is again important to note that individual test sensitivity varied across studies. Variable test performance may have been due to sub-optimal timing of serology, poorly performing assays or misclassification of the reference standard (i.e., labeling non-infected patients as true positive cases based on serology alone). The overall quality of evidence was low due to risk of bias (case control study design) and imprecision as a result of small sample size. The potential benefit of true positive serologic results in patients with clinical signs and symptoms of COVID-19, but repeatedly negative NAAT, is confirmation of diagnosis for epidemiological and prognostic purposes. Additionally, positive results may help reduce unnecessary ancillary testing or empiric therapies directed towards alternative diagnoses. False negative serologic results, especially those obtained early in the course of symptomatic illness, could lead to inadequate isolation or quarantine as well as an under estimation of community A c c e p t e d M a n u s c r i p t prevalence. For example, assuming a prevalence of 40% in 1,000 symptomatic patients with negative NAAT, based on the studies and package inserts that informed the diagnostic accuracy of IgG for recommendations 1 and 2 (above) , there will be 128 to 308 false negatives within the first two weeks of symptom onset compared to 20-48 false negatives during weeks three to five after symptoms onset. Studies in NAAT negative symptomatic patients mainly reported on the use of IgM and IgG antibodies. Given the overall evidence supporting the use of total antibody in the later time periods after symptom onset, it is likely total antibody could also be useful for the evaluation of symptomatic patients presenting late (i.e., three to four weeks after symptom onset) and have repeatedly negative NAAT. Although the timing of testing relative to symptom onset was reported in these case series, exact timing may be difficult to ascertain in routine clinical practice. In addition, most of the studies included in our review involved hospitalized patients with radiographic abnormalities suggestive of viral pneumonia. Severity of illness may correlate with the likelihood of seropositivity [64] . In addition, it is unclear whether RNA detection would have occurred in patients with pneumonia if repeat NAAT testing had been performed using a lower respiratory tract specimen (i.e., sputum or bronchoalveolar lavage fluid) as follow-up of an initial negative upper respiratory swab. In conclusion, assessing anti-SARS-CoV-2 IgG antibodies provides evidence of COVID-19 in patients with high clinical suspicion and negative NAAT results. The timing of antibody testing is important, with optimal sensitivity observed at least two weeks from the time of symptom onset. Ideally, serologic studies of NAAT negative patients should evaluate quantitative antibody We identified 9 case series [65] [66] [67] [68] [69] [70] [71] [72] [73] that evaluated the use of SARS-CoV-2 serologic tests in patients presenting with signs of multisystem inflammatory syndrome in children (MIS-C) ( Table s4 ). The case definitions of this inflammatory syndrome, typically manifesting with fever and shock similar to a Kawasaki-like syndrome, varied across studies and most did not require laboratory evidence of SARS-CoV-2 infection to define the illness. Instead, included studies showed a higher detection rate of MIS-C when IgG antibodies were added to NAAT compared to NAAT alone for the diagnosis. NAAT was positive in approximately 30-50% of cases in these studies, while IgG antibodies were positive in a majority (>80%) of cases. The major limitations of the evidence include the fact that not all case series specified the timing of testing (NAAT or serology) with respect to symptom onset. In addition, the type of serological test utilized and epidemiological links to COVID-19 cases were also not uniformly specified. The overall quality of evidence was very low due to the limitations of the case series study design and serious risk of bias. A c c e p t e d M a n u s c r i p t Children infected with SARS-CoV-2 may have no history of symptomatic disease or known exposure to COVID-19. Therefore, viral and serological testing may be especially important in this population. In fact, positive anti-SARS-CoV-2 antibody testing is now part of the MIS-C case definition. However, false positive results may detract from identifying the true cause of illness. Given the overlap in clinical features and difference in treatment of multisystem inflammatory syndrome diseases, it is important to differentiate MIS-C from Kawasaki Disease and other inflammatory processes such as bacterial infections and rheumatic fever. In clinical practice, young patients with presumed MIS-C are often critically ill and therefore NAAT and IgG serology should be obtained simultaneously. Although we found no studies reporting on the use of total antibody in the setting of MIS-C, it seems likely that these assays could also be useful for defining the syndrome. Evaluation of serology prior to the administration of IVIG or blood products is also important because these therapeutic modalities have the potential to alter the serologic response. We identified three studies [48, 74, 75] and one package insert [76] that compared the diagnostic test accuracy of serologic tests using fingerstick (capillary) blood to venous blood samples obtained via venipuncture (Table s5) . Identified publications included both a cohort study [48] and case control studies [74] [75] [76] . Only one study [76] compared fingerstick to venous blood directly, showing 100% positive and negative percent agreement between the two sampling methods. However, this study was excluded from the analyses because it did not provide diagnostic test accuracy results by week after symptom onset. The remaining studies [48, 74, 75] reported diagnostic test accuracy using fingerstick sampling relative to SARS-CoV-2 NAAT. Due to the lack of evidence comparing the two sampling methods directly, we relied on indirect evidence by using conventional subgroup analysis methods to compare the pooled sensitivities and specificities from LF studies that used fingerstick sampling to the pooled sensitivities and specificities from LF studies that used venous blood [28, 29, 36, 38, 43, 44, 46, 51, 59, 60, [77] [78] [79] [80] [81] [82] [83] [84] . As the timing of sampling seems crucial to evaluate the antibody responses, comparisons for this recommendation were made using data obtained at least two to three weeks after symptom initiation. A c c e p t e d M a n u s c r i p t The included studies provided diagnostic test accuracy results for LF assays using IgM and/or IgG on fingerstick blood collected during week two and three post symptom onset. The pooled sensitivities of IgG collected during week three and the presence of either IgM or IgG collected during weeks two and three using fingerstick blood were comparable to those with venous blood, except for wider confidence intervals with fingerstick blood. IgM collected during week three showed a lower pooled sensitivity when collected using fingerstick compared to venous blood. Of note, the main test modality available for capillary blood testing was LF assays, which may have variations in performance by manufacturer (Figure s3 -Forest Plots) . In sum, there was very low certainty of evidence overall due to a serious risk of bias (i.e., evidence from case-control studies), indirectness (i.e., indirect comparisons as outlined above) and imprecision (due to the small number of studies and/or samples). Capillary blood is usually obtained from a dermal puncture of the fingertip capillary beds and represents a mixture of venous and arterial blood. In general, capillary blood is an ideal specimen for "point-of-care testing" and is often the specimen of choice for those with difficult venous access such as very young infants, elderly patients or severely burned patients. In addition, capillary blood can be used for dried blood spot testing, which can be mailed to the laboratory or preserved for future testing. Since this approach avoids large needles, it may be preferred by individuals who fear needles. Fingerstick collection also facilitates self-collection, which can save on PPE and healthcare worker-facing time. In contrast, a potential harm of fingerstick blood is that the test accuracy (sensitivity and specificity) may be lower compared to venous sampling. The harms of venous blood draw are that it is considered by some to be an unpleasant experience, potentially leading to local side effects such as bleeding or bruising, requires specialized personnel, and use of PPE and healthcare worker-facing time. A c c e p t e d M a n u s c r i p t There is precedent for using capillary blood sampling for the detection of antibodies against other respiratory viruses, such as influenza [85] . Accurate finger stick testing for SARS-CoV-2 antibodies would be ideal when evaluating post-inflammatory complications of COVID-19 such as MIS-C. In addition, point-of-care testing would be useful for deployment in large surveillance projects and contact tracing efforts. Capillary blood testing could also be utilized in clinical trials for monitoring serological response to anti-SARS-CoV-2 vaccines. In summary, there was inadequate information to compare the performance of capillary versus venous blood for the detection of antibodies against SARS-CoV-2. Due to the lack of highquality evidence, the panel reached the conclusion not to recommend for or against use of capillary blood to measure SARS-CoV-2 antibodies. If equivalent performance of capillary blood and venous blood is ultimately confirmed, then there is potential to deploy a simple point-of-care strategy for large-scale assessments of previous SARS-CoV-2 infection. This may also be the serologic test method of choice when larger volumes of blood cannot be obtained (e.g., very young infants). Further studies are needed to demonstrate equivalence of SARS-CoV-2 serological testing using capillary versus venous blood as well as to compare direct sample analysis to dried blood spots. It is likely that the potential impact of sample hemolysis, tissue clotting factors, and specimen volume will be extremely method-dependent. Therefore, understanding each individual assay's test performance will be essential. Accuracy studies should be designed such that venous and capillary blood are taken from the same patient, at the same time, with a robust sample size and excellent clinical characterization of study subjects. Since diagnostic test accuracy may also be affected by A c c e p t e d M a n u s c r i p t clinical parameters (i.e., presence or absence of symptoms, signs and/or radiologic findings, duration of symptoms and disease severity), monitoring over time will be needed to assess waning antibody responses. Understanding the value of capillary blood testing in the context of assessing immunity after vaccination will also be warranted. Finally, beyond fingerstick blood collection, other non-venipuncture-based blood collection devices (especially self-collection) are being developed. As these become available, validation of individual serologic tests with blood collected from individual collection devices will need to be performed. In addition to the clinical questions addressed above, the panel identified several diagnostic approaches currently undergoing evaluation for which additional data are needed to formulate recommendations. Narrative summaries for these approaches are provided below. Neutralizing antibody titers vary among recovered patients [86] , indicating that other parts of the immune system such as T-cells and cytokines are likely to contribute to viral clearance. However, in some COVID-19 recovered individuals, detectable antibodies do correlate with the number of virus-specific T-cells [87] . Standardized assays designed to accurately quantitate nAbs or measure T-cell mediated immunity directed against SARS-CoV-2 do not currently exist but will be needed for comprehensive studies of immunity going forward. Whether nAb titers correlate with protection and/or infectiousness still needs to be determined. Assessing protection also has important implications for vaccine trials, selecting convalescent plasma donors as well as determining which components of the plasma confer anti-viral activity. Classical nAb assays rely on culturing live virus. For SARS-CoV-2, this procedure requires appropriate biocontainment facilities certified for work with BSL-3 pathogens. Pseudovirus assays A c c e p t e d M a n u s c r i p t have been developed to circumvent the safety concerns associated with SARS-CoV-2 culture and, previously, other highly pathogenic viruses [88] . These methods typically use retroviruses capable of integrating the envelope glycoproteins of another virus to form a "pseudovirus." Compared with natural viruses, pseudoviruses can only infect cells in a single round, produce high titer infections and are not easily inactivated by serum complement. Whether nAb titers determined by different pseudovirus assays produce similar results is not yet known and the FDA has yet to authorize use of neutralization tests for SARS-CoV-2. Of note, one small COVID-19 study observed excellent correlation between nAb titers measured by a pseudovirus compared to a live virus assay [86] . In our systematic review, there was no difference in the performance of assays designed to detect the N protein or various portions of the S protein. However, patient sera that reacts with N protein-based tests may be different than the sera that reacts with S protein-based tests [89] . Combining the two antigens in a single test, or sequential testing with two tests targeting different proteins when the first assay is negative, may increase the number of true positive results. Similarly, the CDC has recommended using an orthogonal testing algorithm (i.e., employing two different tests when the first yields a positive result) to increase the positive predictive value of testing when the likelihood of previous exposure to SARS-CoV-2 in the community is low [90] . The logistics, cost and impact of reflexive testing strategies need to be determined prospectively. The immune response to SARS-CoV-2 infection has not yet been fully elucidated. Early evidence suggests that, unlike other infectious diseases, anti-SARS-CoV-2 IgM antibodies become detectable later after symptom onset and rise nearly simultaneously with IgG after two weeks of infection (Figure 1) . Therefore, detection of IgM without IgG is uncommon. In line with other A c c e p t e d M a n u s c r i p t systematic reviews, our antibody comparisons stratified by time post-symptom onset indicate that serologic testing has limited utility for ruling out SARS-CoV-2 infection in the acute phases of illness [91, 92] . Pooled sensitivity estimates for IgM in week two post-symptom onset was 73% ( Interpretation of test specificity also requires caution because little information is available from individuals who were tested due to clinical suspicion of SARS-CoV-2. Moreover, using NAAT as the reference standard may spuriously increase "false positive" serology results, when it is the molecular diagnostic test that is falsely negative. Identifying a better reference standard for future serology studies will help to define the performance of antibody tests. Relying on seroconversion with a documented four-fold rise in IgG titers is suggestive of recent infection. However, most commercial antibody assays do not provide quantitative results and false positive IgG detection is still possible. Correlation of the circulating antibodies detectable with available tests with nAb titers can also provide confidence in positive immunoglobulin results. Whether all individuals, including special populations such as neonates, the elderly or immunocompromised, generate a detectable nAbs response to SARS-CoV-2 also needs to be established. A c c e p t e d M a n u s c r i p t It is important to emphasize that serologic test performance is highly variable and sometimes the same manufacturer's assay performed quite differently across studies. In subgroup analysis, we found no substantive differences in test characteristics (i.e., sensitivity and specificity) based on viral antigen or whether the test has an EUA from the FDA (data not shown). Alternatively, the clinical performance of LF assays was more variable than ELISA or CIA tests. In addition to poorly performing LF tests, factors that may have contributed to heterogeneity across studies include differences in the patient population tested, the exact timing of testing relative to symptom onset and the use of different NAAT assays as the reference standard for comparison. Patients with mild symptoms, or those who are asymptomatic [64] , may display weaker immune responses to SARS-CoV-2 compared to those with severe illness. Standardized reporting of disease severity was not included in most studies. Going forward, serologic assay studies should include a description of the severity of illness using well-defined grading criteria. The exact timing of testing was also not specified in all studies. For example, patients with symptoms for "less than 21 days" likely bridged various time points but were lumped in this guideline in the three-week time period. Uncertainly around the timing of testing could have affected the time-stratified analyses. Perhaps the greatest interest in serologic testing has been for tracking SARS-CoV-2 exposure in the community. Accurate estimates of seroprevalence depend on the true prevalence of past infection in a given population along with the sensitivity and specificity of the test used to detect antibodies. When the true prevalence of infection is low, small decreases from a test sensitivity of 100% have a minimal impact on the negative predictive value of a test, while reductions in specificity artificially inflate measures of seroprevalence. As the true prevalence increases, similar deviations in sensitivity are more impactful, while reductions in specificity are less noticeable. Across the U.S., including regions significantly impacted by COVID-19, the prevalence of past infection is still expected to be relatively low (i.e., <7%) [93, 94] . At the current time, choosing a test with high specificity is especially important to reduce false positive results. A c c e p t e d M a n u s c r i p t Seroprevalence in long term care facilities, congregate settings or factories which have experienced an outbreak are likely to have much higher seroprevalence, but these are situations that do not mirror the broader pandemic in most communities. The magnitude and duration of humoral immune responses to SARS-CoV-2 infection has not been defined. Early evidence suggests that IgG and nAb antibodies begin to decline in the first three months following onset of symptoms in patients with mild COVID-19 similar to seasonal coronaviruses [64, 95] . Clinicians and public health officials need to understand the performance of serology assays used in their settings in order to accurately interpret anti-SARS-CoV-2 antibody test results. Whenever possible, serologic assays with established high sensitivity and specificity (i.e., 99.5%) should be employed. IgG and total antibody tests appear to have better sensitivity and specificity than other immunoglobulin classes and perform best when used between three to four weeks after The following list displays what has been reported to the IDSA. To provide thorough transparency, the IDSA requires full disclosure of all relationships, regardless of relevancy to the guideline topic. Evaluation of such relationships as potential conflicts of interest is determined by a review process which includes assessment by the Board of Directors liaison to the Standards and Practice Guideline Committee and, if necessary, the Conflicts of Interest (COI) and Ethics Committee. The assessment of disclosed relationships for possible COI is based on the relative weight of the financial relationship (i.e., monetary amount) and the relevance of the relationship (i.e., the degree to which an association might reasonably be interpreted by an independent observer as related to the topic or recommendation of consideration World Health Organization. Coronavirus disease (COVID-19) situation reports The receptor-binding domain of the viral spike protein is an immunodominant and highly specific target of antibodies in SARS-CoV-2 patients Structure, Function, and Antigenicity of the SARS-CoV-2 Spike Glycoprotein Two linear epitopes on the SARS-CoV-2 spike protein that elicit neutralising antibodies in COVID-19 patients Neutralizing Antibodies against SARS-CoV-2 and Other Human Coronaviruses The Nucleocapsid Protein of SARS-CoV-2: a Target for Vaccine Development Antiviral antibody responses: the two extremes of a wide spectrum Serological Approaches for COVID-19: Epidemiologic Perspective on Surveillance and Control Development of rapid guidelines: 3. GIN-McMaster Guideline Development Checklist extension for rapid recommendations Spread of SARS-CoV-2 in the Icelandic Population Triaging patients in the outbreak of the 2019 novel coronavirus Preliminary Results of Initial Testing for Coronavirus (COVID-19) in the Emergency Department Optimizing diagnostic strategy for novel coronavirus pneumonia, a multi-center study in Eastern China Positive rate of RT-PCR detection of SARS-CoV-2 infection in 4880 cases from one hospital in GRADE guidelines: 2. Framing the question and deciding on important outcomes Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews Seriously misleading results using inverse of Freeman-Tukey double arcsine transformation in meta-analysis of single proportions Random effects meta-analysis of event outcome in the framework of the generalized linear mixed model with applications in sparse data R: A language and environment for statistical computing. R Foundation for Statistical Computing mada: Meta-Analysis of Diagnostic Accuracy How to perform a meta-analysis with R: a practical tutorial QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies GRADE guidelines: 21 part 1. Study design, risk of bias, and indirectness in rating the certainty across a body of evidence for test accuracy GRADE guidelines: 21 part 2. Test accuracy: inconsistency, imprecision, publication bias, and other domains for rating the certainty of evidence and presenting it in evidence profiles and summary of findings tables GRADEpro Guideline Development Tool Available at: gradepro.org Clinical evaluation of serological IgG antibody response on the Abbott Architect for established SARS-CoV-2 infection Comparison of the Elecsys(R) Anti-SARS-CoV-2 immunoassay with the EDI enzyme linked immunosorbent assays for the detection of SARS-CoV-2 antibodies in human plasma Kinetics of the humoral immune response to SARS-CoV-2: comparative analytical performance of seven commercial serology tests Clinical evaluation of an immunochromatographic IgM/IgG antibody assay and chest computed tomography for the diagnosis of COVID-19 Diagnostic accuracy of an automated chemiluminescent immunoassay for anti-SARS-CoV-2 IgM and IgG antibodies: an Italian experience Evaluations of serological test in the diagnosis of 2019 novel coronavirus (SARS-CoV-2) infections during the COVID-19 outbreak Evaluation of Nucleocapsid and Spike Protein-Based Enzyme-Linked Immunosorbent Assays for Detecting Antibodies against SARS-CoV-2 Antibody profiles in mild and severe cases of COVID-19 Serology characteristics of SARS-CoV-2 infection since exposure and post symptom onset Serum IgA, IgM, and IgG responses in COVID-19 Multi-site Validation of a SARS IgG/IgM Rapid Antibody Detection Kit. medRxiv 2020: 2020.05.25 Study on the expression levels of antibodies against SARS-CoV-2 at different period of disease and its related factors in 192 cases of COVID-19 patients Comparative assessment of multiple COVID-19 serological technologies supports continued evaluation of point-of-care lateral flow assays in hospital and community healthcare settings SARS-CoV-2 antibody characterization in emergency department, hospitalized and convalescent patients by two semiquantitative immunoassays Delayed specific IgM antibody responses observed among COVID-19 patients with severe progression Longitudinal Monitoring of SARS-CoV-2 IgM and IgG Seropositivity to Detect COVID-19 Performance Characteristics of Four High-Throughput Immunoassays for Detection of IgG Antibodies against SARS-CoV-2 Diagnostic performance of seven rapid IgG/IgM antibody tests and the Euroimmun IgA/IgG ELISA in COVID-19 patients Antibody Detection and Dynamic Characteristics in Patients with COVID-19 Evaluation of COVID-19 IgG/IgM Rapid Test from Orient Gene Biotech Validation of a commercially available SARS-CoV-2 serological Immunoassay Evaluation of performance of two SARS-CoV-2 Rapid whole-blood finger-stick IgM-IgG Combined Antibody Tests Clinical evaluation of a rapid colloidal gold immunochromatography assay for SARS-Cov-2 IgM/IgG ELISA (IgG) Instruction for use (package insert) Treatment of 5 Critically Ill Patients With COVID-19 With Convalescent Plasma VITROS Immunodiagnostic Products Anti-SARS-CoV-2 IgG Instructions for use Siemens Healthcare Diagnostics Dimension EXL SARS-CoV-2 Total antibody assay (CV2T) (package insert) Siemens Healthcare Diagnostics Dimension Vista SARS-CoV-2 Total antibody assay (COV2T) (package insert) Clinical infectious diseases : an official publication of the Infectious Diseases Society of A preliminary study on serological assay for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in 238 admitted hospital patients Serological immunochromatographic approach in diagnosis with SARS-CoV-2 infected COVID-19 patients Alltest rapid lateral flow immunoassays is reliable in diagnosing SARS-CoV-2 infection from 14 days after symptom onset: A prospective single-center study Evaluation of Enzyme-Linked Immunoassay and Colloidal Gold-Immunochromatographic Assay Kit for Detection of Novel Coronavirus (SARS-Cov-2) Causing an Outbreak of Pneumonia (COVID-19). medRxiv Longitudinal Change of SARS-Cov2 Antibodies in Patients with COVID-19 Antibody responses to SARS-CoV-2 in patients of novel coronavirus disease 2019. Clinical infectious diseases : an official publication of the Infectious Diseases Society of Clinical and immunological assessment of asymptomatic SARS-CoV-2 infections Acute heart failure in multisystem inflammatory syndrome in children (MIS-C) in the context of global SARS-CoV-2 pandemic Multisystem Inflammatory Syndrome in Children in New York State Multisystem Inflammatory Syndrome in U.S. Children and Adolescents Acute myocarditis and multisystem inflammatory emerging disease following SARS-CoV-2 infection in critically ill children Serology confirms SARS-CoV-2 infection in PCR-negative children presenting with Paediatric Inflammatory Multi-System Syndrome Hyperinflammatory shock in children during COVID-19 pandemic Kawasaki-like multisystem inflammatory syndrome in children during the covid-19 pandemic in Paris, France: prospective observational study An outbreak of severe Kawasaki-like disease at the Italian epicentre of the SARS-CoV-2 epidemic: an observational cohort study Clinical Characteristics of 58 Children With a Pediatric Inflammatory Multisystem Syndrome Temporally Associated With SARS-CoV-2 Analytical performance of lateral flow immunoassay for SARS-CoV-2 exposure screening on venous and capillary blood samples Sensitivity and specificity of a rapid test for assessment of exposure to SARS-CoV-2 in a community-based setting in Brazil ACCELERATED EMERGENCY USE AUTHORIZATION (EUA) SUMMARY VIBRANT COVID-19 AB ASSAY ((VIBRANT AMERICA CLINICAL LABS). Available at Antibody testing for COVID-19: A report from the National COVID Scientific Advisory Panel Utility of lateral flow tests in SARS-CoV-2 infection monitorization Serologic responses to SARS-CoV-2 infection among hospital staff with mild disease in eastern France Detection of serum immunoglobulin M and immunoglobulin G antibodies in 2019 novel coronavirus infected patients from different stages Evaluation of nine commercial SARS-CoV-2 immunoassays Clinical evaluation of a rapid colloidal gold immunochromatography assay for SARS-Cov-2 IgM/IgG Detection of SARS-CoV-2 antibodies using commercial assays and seroconversion patterns in hospitalized patients Different longitudinal patterns of nucleic acid and serology testing results based on disease severity of COVID-19 patients Evolution of an influenza pandemic in 13 countries from 5 continents monitored by protein microarray from neonatal screening bloodspots Detection of SARS-CoV-2-Specific Humoral and Cellular Immunity in COVID-19 Convalescent Individuals Breadth of concomitant immune responses prior to patient recovery: a case report of non-severe COVID-19 Current status on the development of pseudoviruses for enveloped viruses Comparison of the diagnostic sensitivity of SARS-CoV-2 nucleoprotein and glycoprotein-based antibody tests Interim Guidelines for COVID-19 Antibody Testing in Clinical and Public Health Settings Antibody tests for identification of current and past infection with SARS-CoV-2 Diagnostic accuracy of serological tests for covid-19: systematic review and meta-analysis Seroprevalence of Antibodies to SARS-CoV-2 in 10 Sites in the United States Population Point Prevalence of SARS-CoV-2 Infection Based on a Statewide Random Sample -Indiana Rapid Decay of Anti-SARS-CoV-2 Antibodies in Persons with Mild Covid-19