key: cord-0988693-zu3zsdz9 authors: Zhang, Xian; Chen, Liting; Wang, Gaoxiang; Chen, Liwen; Huang, Lifang; Cao, Yang; Chen, Xing; Deng, Chaohua; Chen, Xuhui; Ke, Dandan; Qin, Yuanjun; Chen, Bo; Sun, Xufang title: Investigation of SARS-CoV-2 on Ocular Surface of Coronavirus Disease 2019 Patients Using One-Step Reverse-Transcription Droplet Digital PCR date: 2021-12-15 journal: Infect Drug Resist DOI: 10.2147/idr.s335635 sha: ed03fb6c85bd5fa20055a12d949aca755f94cc8b doc_id: 988693 cord_uid: zu3zsdz9 PURPOSE: This study detects SARS-CoV-2 in the ocular surface through one-step reverse-transcription droplet digital PCR (one-step RT-ddPCR) and evaluates the possibility of the ocular surface as a possible transmission route. METHODS: A single-center prospective observational study was designed to investigate the viral loads in ocular surface. Specimens including the conjunctival swabs, nasopharyngeal swabs and blood were synchronously collected at a single time point for all COVID-19 patients. SARS-CoV-2 loads in nasopharyngeal swabs were tested by real-time polymerase chain reaction (PCR); the blood samples and conjunctival swabs were tested by real-time PCR and one-step RT-ddPCR. RESULTS: Sixty-eight COVID-19 patients confirmed by nasopharyngeal real-time PCR were recruited. In the single time point test, 40 cases showed positive SARS-CoV-2 detection in either the blood, tears, or nasopharynx, of which four cases were triple-positive, 10 were dual-positive, and 26 were single-positive. The positive rate of nasopharyngeal swab real-time PCR test was 22.1% (15/68). The positive rate of blood and conjunctival swabs by one-step RT-ddPCR was 38.2% (26/68) and 25% (17/68), respectively, whereas real-time PCR was all negative. Positive conjunctival swabs were significantly correlated with positive nasopharyngeal swabs (P = 0.028). The sampling lags from illness onset to sampling day in 3 out of 4 triple-positive patients and in 9 out of 10 dual-positive patients were respectively less than 9 days and less than 20 days. CONCLUSION: Our results indicate that the positive rate of SARS-CoV-2 on the ocular surface is much higher than expected. Transmission possibility through the ocular surface may be greatly underestimated. Coronavirus disease 2019 (COVID-19) is a global pandemic and as of November 3, 2020, nearly 46 million cases and 1.2 million deaths have been reported globally. 1 The highly contagious COVID-19 is caused by the infection of the SARS-CoV-2 virus, and respiratory tract transmission and contact transmission are considered its main infection routes. 2, 3 The SARS-CoV-2 virus has been tested in nasopharyngeal swabs as well as in other specimens such as feces, ocular secretions, and blood, suggesting that various potential transmission routes of this previously unknown infectious virus should be considered seriously. 4, 5 Whether the ocular surface can transmit the virus has been widely debated. A previous study reported that realtime polymerase chain reaction (PCR) failed to detect SARS-CoV-2 in the tears of COVID-19 patients; 6 other groups have detected SARS-CoV-2 nucleic acids in the tears of very a few COVID-19 patients by using SARS-CoV-2 real-time PCR assays. [7] [8] [9] Thus, the overall positive rate of conjunctival swabs by real-time PCR are extremely low. However, considering that real-time PCR has a non-negligible falsenegative rate even in the pharynx tests and the sample volume of tears is far less than the pharynx sample, the falsenegative rate for SARS-CoV-2 real-time PCR tests for tears should be seriously excluded. In other words, more sensitive methods are needed to determine whether there is SARS-CoV-2 in ocular surface. Droplet digital PCR (ddPCR) is an absolute nucleic acid quantification method that affords many advantages over real-time PCR for virus detection, including the ability to obtain absolute quantification without external references and robustness to variations in PCR efficiency. 10 Several studies showed that ddPCR is more sensitive and reliable for detecting low-viral-load samples than real-time PCR in COVID-19 patients. [10] [11] [12] Similarly in our latest study, one-step RT-ddPCR was proved to be a highly sensitive detection method with a 3.03% of false positive rate and lower 50% confidence interval of detection (LOD50) at 54.026 copies/mL plasma. 13 In this study, considering the sensitivity limitations of real-time PCR and the low sample volume of tears, we applied one-step reverse-transcription ddPCR (RT-ddPCR) for conjunctival swabs, which is even more sensitive than conventional ddPCR to determine the viral load of SARS-CoV-2 on ocular surface. Participants presented in this single-center prospective observational study were hospitalized newly diagnosed COVID-19 pneumonia patients (N=68) with informed consents between February 12, 2020 and March 10, 2020, in Tongji Hospital of Huazhong University of Science and Technology in Wuhan, China, according to the WHO guidance. 14 The diagnosis and the illness severity of COVID-19 were defined according to the Chinese management guideline for COVID-19 (version 7.0) and the World Health Organization interim guidance. 14 Patients meeting any of the following criteria were defined as severe status: 1) respiratory distress (≧30 breaths/min); 2) oxygen saturation ≤93% at rest; 3) arterial partial pressure of oxygen (PaO 2 )/fraction of inspired oxygen (FiO 2 )≦ 300mmHg (l mmHg=0.133kPa). This study complied with the Declaration of Helsinki and was approved by the Ethics Committee of Tongji Hospital (TJ-C20200113) . Informed consent was obtained from each patient or patients' relatives if patients were not in good condition. Exclusion criteria of this study enrollment included: 1) suspicious cases without positive nasopharyngeal swab results by RT-PCR; 2) no written informed consent could be obtained; 3) patients had received remdesivir or were involved in other clinical trials. Every participant synchronously provided three types of specimens including serum, nasopharyngeal swabs and conjunctival swabs on the enrollment day. All samples were collected and immediately transferred to a 4°C refrigerator and processed within 24 hours. Harvested serum and viral-transport medium for swab preservation were immediately assayed or aliquoted to be stored at ≤−80 °C. Repeated freeze-thaw cycles were avoided. All types of these samples were tested by the well-accepted conventional RT-PCR. In light of the relative lower SARS-CoV-2 detection rate of serum and tear specimens by RT-PCR, these two types of samples were additionally detected by one-step RT-ddPCR. Clinical informations were inputted in an electronic data capture system (EDCS) and extracted for further analysis. The time from the illness onset to specimens' collection was defined as the sampling lag. Detection of SARS-CoV-2 by Conventional Real-Time PCR SARS-CoV-2 was tested through the real-time PCR of SARS-CoV-2 RNA, as reported previously. 15 Two target genes, including open reading frame 1ab (ORF1ab) and nucleocapsid protein (N), were simultaneously amplified and tested during the real-time PCR assay (Supplementary Table S1) . A cycle threshold value (Ct-value) less than 37 was defined as a positive test, and a Ct-value of 40 or more was defined as a negative test. These diagnostic criteria were based on the recommendation by the National CDC (China). A medium load, defined as a Ct value of 37 to less than 40, required confirmation by at least two repeats. Samples were considered as negative when their Ct values were higher than 40. SARS-CoV-2 plasmids with orf1ab inserted (Sangon Biotech, Shanghai, China) were linearized by restriction enzyme BamHI, serially diluted and subjected to ddPCR amplification. Detailed protocol and quality control of one-step RT-ddPCR of SARS-CoV-2 RNA was referred to our recent published article. 13 Briefly, for the quantitative detection of SARS-CoV-2 copy numbers, a viral RNA purification kit (QIAamp Viral RNA Mini Kit, Qiagen 52904#, Germany), one-step RT-ddPCR advanced kit, QX200 droplet generator (BioRad, USA), and QX200 droplet reader (BioRad, USA) were used following the manufacturers' instructions. A 2-well test was performed for each sample in this study. The SARS-CoV-2 specific minor groove binder (MGB) probe-primer set was designed for targeting the orf1ab region, and the sequences were attached in Supplementary Table S1 . The probe-primer set has been previously reported by our center. 13 For ddPCR analysis, QuantaSoft software version 1.7.4 (Bio-Rad, USA) was used to quantify the copies per microliter of the target per well. Thresholds were determined manually for each experiment according to negative controls that included a no-template control and four healthy samples. Droplet positivity was determined by the fluorescence intensity; only droplets above a minimum amplitude threshold were counted as positive. Negative control plasma and conjunctival samples from 16 healthy persons were used to estimate the specificity of the probe. LLoD which is defined as the lowest concentration at which 50% of positive samples were detected using serially diluted plasmid standards in eight replicates. All clinical samples were run in duplicate, unless otherwise specified, and the viral load was taken as the average of the two measurements. Categorical variables were described using the frequency rates and percentages, and continuous variables were described using the median and interquartile range (IQR). Univariate analyses were assessed with χ2 test of association for categorical values, and P < 0.05 was considered a significant difference. Multiple comparisons were made by utilizing Dunn's multiple comparisons test. Probit analysis for lower limit of detection (LLoD) was conducted with GraphPad Prism 7.0. Of these 68 enrolled COVID-19 patients, none of them had any symptoms regarding viral conjunctivitis. The median age was 58.3 years (IQR: 47-70) with gender ratio of 33/35 (M/F). The general and severe status was 81.9% and 19.1%, respectively. Of note, the study cohort did not contain critical status since most of these patients could not afford written informed consents. Comorbidities were present in 48.5% of the patients, with hypertension and diabetes being the most common ones. Sampling lags were ranging from 6 days to over 1 month. Fourteen of 68 (20.6%) patients provided samples less than 10 days from illness onset, whereas 20 of which (29.4%) was over 20 days. The majority (50%) of sampling lags was ranging from 10 to 20 days after the onset time. According to CT scans, 53 patients showed bilateral pneumonia (77.9%) and just 15 (22.1%) showed unilateral pneumonia ( Table 1 ). Commercial SARS-CoV-2 plasmids were used to evaluate the accuracy and LLoD of ddPCR detection. Plasmids were twofold serially diluted at the concentrations ranging from approximately 800 copies/µL to 12.5 copies/µL and subjected to ddPCR amplification. Each concentration, measured in triplicate, was well in line with expected concentration (R 2 = 0.998, P < 0.001), indicating that ddPCR using the probeprimer set for SARS-CoV-2 could accurately quantify SARS-CoV-2 copies ( Figure 1A) . To determine the LLoD which is defined as the lowest concentration at which 50% of positive samples were detected, eight replicates of each concentration were tested. The LLoD of plasmid standards was 10 copies per reaction ( Figure 1B) . The probe-primer set showed high specificity as all negative control samples had zero viral load. Thus, the false positivity for this probe-primer set was 0. We tracked the presence of the SARS-CoV-2 RNA in tear and blood samples from 68 patients using real-time PCR and one-step RT-ddPCR. Notably, viral load in our cohort was not detected either in blood or tears using real-time PCR. On the contrary, SARS-CoV-2 RNA was detected in both blood and tear by one-step RT-ddPCR, and the positive rates were 38.2% (26/68) and 25% (17/68), respectively. However, the viral loads in these positive cases were generally very low, ranging from 125 to 553.6 copies/mL (Figure 2 ), which below the detection limit of real-time PCR. The positive rate of nasopharyngeal swabs in our single time point test was only 22.1% (15/68). In total, 40 cases showed positive SARS-CoV-2 detection in either the blood, tears, or nasopharynx, of which four cases were triple-positive, 10 were dual-positive; and 26 were singlepositive ( Figure 3) . Moreover, the sampling lags from illness onset to sampling day in 3 out of 4 triple-positive patients and in 9 out of 10 dual-positive patients were respectively less than 9 days and less than 20 days, indicating that the multiple-positive patients are mainly identified at a relatively early stage of COVID-19 ( Figure 3 ). Positive One-Step RT-ddPCR Tear Specimens are Significantly Correlated with Positive Real-Time PCR Nasopharyngeal Specimens Table 2 shows the factors associated with the positive rate for one-step RT-ddPCR. Clinical factors were compared between conjunctival viral positive and negative patients for one-step RT-ddPCR in terms of gender, severity of COVID-19, time from onset to sampling, CT laterality, and positive rate of blood. No significant statistical differences in these factors were found between these two groups. Positive conjunctival swabs seemed to be more likely to occur in elderly patients, but there was no statistical difference (P = 0.22, Table 2 ). Nevertheless, the SARS-CoV-2 viral loads of nasopharyngeal specimens were significantly correlated with those of conjunctival specimens (P = 0.028, Table 2 ). We systematically tested the viral RNA of SARS-CoV-2 in tear specimens by using real-time PCR and one-step RT-ddPCR. Our results indicate that the viral load in tears is very low, which is below the detection limit of real-time PCR, whereas one-step RT-ddPCR is more sensitive and yields a positive rate of ~25% for the same tear samples. Taking account that the simultaneously positive rate of nasopharyngeal sample test in these previous positive cases was only 22.1%, we speculate that the viral test by one-step RT-ddPCR in tears may yield a much higher positive rate if the test is performed earlier. Thus, the ability of transmission through the ocular surface may be greatly underestimated. When we are directly or indirectly exposed to patient's eye discharges or tears, appropriate ocular hygiene habits may be essential to prevent the spread of SARS-CoV-2. It is recommended for clinicians and ophthalmologists to use personal protective equipment (PPE) for eyes while examining patients. Although nasopharyngeal swab tests for SARS-CoV-2 RNA by real-time PCR is considered as the gold standard for diagnosis, given that some clinical observations reported that the positive detection rate was only 30%-60%, 16 real-time PCR is inadequate for testing tear .samples 17 Thus, in our study, only one-step RT-ddPCR successfully detected the virus in tears, suggesting that it is highly sensitive and is a feasible tool for the detection of the viral load in tears. In particular, considering that the tear sample is greatly diluted by the virus preservation solution, the low concentration of the virus in the preservation solution does not imply a low viral load in tears. We analyzed the risk factors of tear positive patients and found no significant correlation with age, gender, disease severity, and CT findings. Interestingly, we found a significant correlation between tears and nasopharynxpositive patients but no correlation between tears and bloodpositive patients. We speculate that this may be owing to the expression of SARS-CoV-2-related receptors (ACE2 and CD147) in both the respiratory tract and ocular surface; this makes the virus more easily enriched in these two parts. [18] [19] [20] [21] [22] Second, to the best of our knowledge, the ocular surface could connect with the respiratory tract through the nasolacrimal duct, and mucosal immune properties permitted the eye to be both a potential virus infected site as well as a gateway for respiratory infection. 23 Notably, although animal experiments have confirmed that the SARS-CoV-2 can be inoculated through the eyes, it is still necessary to isolate the virus in the eyes to further prove that the virus can be transmitted through the eyes. In our study, most triple-positive patients were sampled within 9 days after the illness onset, and most dual-positive patients were sampled within 20 days after the illness onset. A previous study reported that the SARS-CoV-2 viral load in throat swab and sputum samples was significantly correlated with the course of COVID-19: these viral loads peaked around 5-6 days after the onset of symptoms and gradually decreased until they could not be detected. 24 Our findings agree with this dynamic law of SARS-CoV-2: the earlier the course of COVID-19 is, the higher the positive rate is, indicating a wider viral distribution and a higher viral load at the early stage. In fact, most of the cases were sampled over 1 week after the onset of symptoms, which means we might not catch the time window with the highest viral load. Although our research has some important findings, there are still some limitations. First, as mentioned previously, our study did not enroll the early-stage COVID-19 patients who mainly remained in the community. For this reason, this study could not reflect the viral load in tears at the very early stage of COVID-19. Second, owing to the low incidence rate of conjunctivitis as well as the sharp decline of newly diagnosed cases, this study could not investigate the viral load in COVID-19 patients with conjunctivitis. Thus, further studies are better to investigate the viral load from the very early stage as well as in coexisting conjunctivitis patients. In conclusion, by using one-step RT-ddPCR, our study demonstrates that the positive rate of SARS-CoV-2 in tears is greatly underestimated. Due to the dilution effect by the virus preservation solution, the low concentration of the virus in the preservation solution may not imply a low viral load in tears. Our study shows that the virus has a molecular basis for ocular transmission, but further study is needed to investigate its infectivity through eyes. COVID-19 weekly epidemiological update World Health Organization Severe acute respiratory syndrome-related coronavirus: the species and its virusesa statement of the coronavirus study group World Health Organization. Coronavirus The presence of SARS-CoV-2 RNA in feces of COVID-19 patients The evidence of SARS-CoV-2 infection on ocular surface Assessing viral shedding and infectivity of tears in coronavirus disease 2019 (COVID-19) patients Evaluation of coronavirus in tears and conjunctival secretions of patients with SARS-CoV-2 infection Ophthalmologic evidence against the interpersonal transmission of 2019 novel coronavirus through conjunctiva. medRxiv Preprint Coronavirus in the conjunctival tears and secretions in patients with SARS-CoV-2 infection in Sohag Province Absolute quantification by droplet digital PCR versus analog real-time PCR Quantitative detection and viral load analysis of SARS-CoV-2 in infected patients One-step RT-droplet digital PCR: a breakthrough in the quantification of waterborne RNA viruses Dynamics of blood viral load is strongly associated with clinical outcomes in COVID-19 patients: a prospective cohort study Clinical management of severe acute respiratory infection when novel coronavirus (nCoV) infection is suspected: interim guidance Early transmission dynamics in Wuhan, China, of novel coronavirus-infected pneumonia Detection of SARS-CoV-2 in different types of clinical specimens Tear volume in normal eyes and keratoconjunctivitis sicca Expression of SARS coronavirus S protein functional receptor ACE2 in human and rabbit cornea and conjunctiva Structural and functional basis of SARS-CoV-2 entry by using human ACE2 SARS-CoV-2 invades host cells via a novel route: CD147-spike protein Immunolocalization of EMMPRIN (CD147) in the human eye and detection of soluble form of EMMPRIN in ocular fluids Angiotensin converting enzyme 2: SARS-CoV-2 receptor and regulator of the renin-angiotensin system Ocular tropism of respiratory viruses Viral load of SARS-CoV-2 in clinical samples All authors made a significant contribution to the work reported, whether that is in the conception, study design, execution, acquisition of data, analysis and interpretation, or in all these areas; took part in drafting, revising or critically reviewing the article; gave final approval of the version to be published; have agreed on the journal to which the article has been submitted; and agree to be accountable for all aspects of the work. This study was funded by grants from the National Natural Science Foundation of P.R. China (Grant No. 81974136) and grants from the Huazhong University of science and Technology Foundation of P.R. China (Grant No. 2020kfyXGYJ068). The funding source had no role in the design and conduct of the study; collection, management, analysis, and interpretation of the data; preparation, review, or approval of the manuscript; and decision to submit the manuscript for publication. The authors declare no competing interests. Infection and Drug Resistance is an international, peer-reviewed openaccess journal that focuses on the optimal treatment of infection (bacterial, fungal and viral) and the development and institution of preventive strategies to minimize the development and spread of resistance. The journal is specifically concerned with the epidemiology of antibiotic resistance and the mechanisms of resistance development and diffusion in both hospitals and the community. The manuscript management system is completely online and includes a very quick and fair peerreview system, which is all easy to use. Visit http://www.dovepress.com/ testimonials.php to read real quotes from published authors.