key: cord-0988560-7vx08v1i authors: Martinez-Gallo, M.; Esperalba-Ezquerra, J.; Pujol-Borrell, R.; Sanda, V.; Arrese-Munoz, I.; Fernandez-Naval, C.; Anton-Pagarolas, A.; Cardona, V.; Labrador-Horrillo, M.; Pumarola-Sune, T.; Hernandez-Gonzalez, M. title: T-cell responses as a correlate of COVID-19 vaccination. A pilot study in Health Care Workers. date: 2021-04-05 journal: nan DOI: 10.1101/2021.03.31.21254472 sha: f4881b75e50598ffa9ddddcda923f2b64044200b doc_id: 988560 cord_uid: 7vx08v1i Background: Clinical trials on the different vaccines to SARS-CoV-2 have demonstrated protection efficacy, but it is urgent to assess the levels of protection generated with real-world data, especially in individuals professionally exposed. Measuring T-cell responses may complement antibody tests currently in use as correlates of protection but there are not validated T-cell responses applicable to large number of samples. Objective: To assess the feasibility of using T-cell responses to SARS-CoV-2 S peptides by commercially available whole blood interferon-gamma release assays (IGRA) as a correlate of protection. Patients: Twenty health care workers before and after vaccination. Methods: Antibody test to SARS-CoV-2 N and S proteins in parallel with one IGRA assay and two detection techniques than can be automated. Results: IGRA test detected T-cell responses in naturally exposed and vaccinated HCW already after first vaccination dose. the correlation by the two detection methods, CLIA and ELISA, very high (R>0.9) and sensitivity and specificity ranged between 100 and 86% and 100-73% respectively. Even though there was a very high concordance between antibody and the IGRA assay in the ability to detect immune response to SARS-CoV-2 there was a relatively low quantitative correlation. In the small group primed by natural infection, one vaccine dose was sufficient to reach immune response plateau. IGRA was positive in one Ig (S) antibody negative vaccinated immunosuppressed HCW illustrating another advantage of the IGRA test. Conclusion: Whole blood IGRA tests amenable to automation, as the one here reported, constitute a promising additional tool for measuring the state of the immune response to SARS-CoV-2; they are applicable to large number of samples and may become valuable correlates of protection to COVID-19, particularly for vulnerable groups at risk of being re-exposed to infection, as are health care workers. Commercial kits of whole blood Interferon-gamma release assay (IGRA) constitute an reliable method for clinical laboratories to assess T-cell response after natural infection by SARS-CoV-2 and after BNT162b2 mRNA vaccination and are suitable for large scale application.  Commercial kits of whole blood interferon-gamma release assay (IGRA) are potentially very useful tools to measure the T cell response to SARS-CoV-2 after COVID-19 and after SARS-CoV-2 vaccination.  One vaccine dose restores T cell response in COVID recovered patients, but the vaccination boost was required for naïve participants to attain a comparable response.  T cell response seem to decay in COVID recovered subjects after the boost second vaccination dose. Measuring T cell responses by commercially available whole blood interferon gamma release assays (IGRA) provide a promising additional correlate of protection to COVID and may be useful to reassure vulnerable group professionals at risk of being exposed to SARS-CoV-2 infection. SARS-CoV-2 BNT162b2 mRNA COVID-19 vaccine Interferon-gamma release assays Cell mediated immunity Health care workers (HCWs) Interferon-gamma release assays (IGRA) Chemiluminescence immunoassays (CLIA) Enzyme linked immunosorbent assay (ELISA) Complete blood count (CBC) Spike protein (S) Nucleocapsid protein (N) One of the groups with the highest incidence of COVID-19 in the present pandemic has been Health Care Workers (HCW). In the last month of 2020 worldwide vaccination campaign to SARS-CoV-2 began and, in most countries, front line HCWs have been among the first group receiving the new vaccines. SARS-CoV-2 infection produces detectable immune responses in most cases. As part of the adaptive response to infection, humans generate SARS-CoV-2specific antibodies and specific T lymphocytes (1) . Several studies on acute and convalescent COVID-19 patients have demonstrated that SARS-CoV-2-specific T cell responses control viral replication and reduce disease severity (2) . Anti-spike (S) and anti-nucleocapsid (N) proteins IgG antibodies are associated to greatly reduced risk of SARS-CoV-2 reinfection in the 6 months after COVID-19(3). S-antigen mRNA-based vaccines against SARS-CoV2 (Pfizer-BioNTech and Moderna) have demonstrated immunogenicity (typically evaluated by serology) with 95% efficacy in more than 2 million HCW without major safety issues in all phases of human trials (4). Although clinical trial data of vaccines in use are excellent in terms of effectiveness, real-world evidence remains scarce. In particular, no papers have been published evaluating the development of T cell responses after vaccination using commercial kits suitable for large scale application. One issue arisen in the health system -as in other essential sectors-is how to reassure HCWs, especially those pertaining to vulnerable groups e.g., diabetics, that, after overcoming COVID-19 or vaccination, they are reasonably protected and can reassume their duties. Here we present a pilot study of SARS-CoV-2 specific antibody and T responses to Spike protein (S) after mRNA vaccination in a small group of health care workers (HCWs) at Hospital Universitari Vall d'Hebron, Barcelona, Spain (HUVH) using one commercially available test suitable for clinical laboratories, amenable to automation and therefore applicable to large number of samples. Twenty HCWs on follow-up since May 2020 were recruited as part of a longitudinal study of seroprevalence and clinical impact of COVID-19 HUVH, a major academic hospital with over 6500 staff. All participants were tested before first dose (median 4 days, IQR 3), after first dose (median 22 days, IQR 1) and after the second dose (median 13 days, IQR 0) of the BNT162b2 mRNA COVID-19 vaccine (Pfizer-BioNTech, Mainz, Germany). Demographic, epidemiological, and clinical data were collected using a standard questionnaire (supplementary table 1). Five All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 5, 2021. Antibody responses were measured in the clinical microbiology laboratory using two widely applied commercial CLIA assays; antibodies (IgG, IgM and IgA) to nucleocapsid (N) SARS-CoV-2 protein were detected by the qualitative Elecsys® Anti-SARS-CoV-2 test in a Cobas 8800 system autoanalyzer (both from Roche); IgG antibodies to the Spike protein were measured by the quantitative LIAISON® SARS-CoV-2 S1/S2 IgG test in a XL Analyzer (DiaSorin, Cypress, CA, USA). Samples with antibody levels >800 were diluted according to the manufacturer's instructions. Data were analyzed by non-parametric tests; Mann-Whitney test for comparisons between the COVID and NO-COVID groups, and Friedman test for comparisons between paired values, and correlation studies to compare variables was calculated by Pearson correlation coefficient. GraphPad Prism v8.01 software was used for both statistical analysis and graphical representation. At enrolment COVID Group participants (n=5) had detectable IgG (N) antibodies while those in the NO-COVID Group, (n=15) were all negative, thus excluding the presence of asymptomatic cases in the latter group ( Figure 1A ). IgG(S) antibodies were measured at three time points: All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 5, 2021. Cut-off points for each variant of the IGRA assay were calculated by ROC analysis with the following results: CLIA cut-off point was > 0.051 IU IFN-gamma/ml with a sensitivity of 86% and specificity of 100% for Ag1 and > 0.442 for Ag2 with a sensitivity 100% and a specificity 73% (Supplementary Figure 1) . The cut-off point for the ELISA was >0.0065 IU IFN-gamma/ml for Ag1 with a sensitivity of 86.67% and specificity 92% and for Ag 2 > 0.024 with a sensitivity of 80% and a specificity of 100%. Correlation between Ag1 and Ag2 results was very high (R=0.9 for ELISA and 0.8 for CLIA (data not shown). In general Ag.2 induced higher responses than Ag.1, and. A positive response to either of the two peptides pools should be considered, in principle a positive result. From these results it is not clear the need of using the Ag. 1 pool of peptides but this may be different in a larger group with a more diverse genetic background. Overall quantitative correlation between the antibody and T cell responses was low (R in the order of 0.2) (Supplementary figure 2) but there was a good concordance in detecting the immune response to Spike. Sensitivity of the IGRA test may be superior in this group to IgG(S) antibody test due to the presence of one anti-CD20 treated participant (see below, illustrative case 12), but due to the small size, conclusions cannot be drawn. Interestingly four of the five post COVID participants did not respond in the IGRA test prior to vaccination, but one dose was sufficient to reach good levels of IFN-gamma production, indicating priming by the natural infection. Second dose rather reduced the response, perhaps because due to the time elapsed since priming, response contracted more quickly, this All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 5, 2021. ; https://doi.org/10.1101/2021.03.31.21254472 doi: medRxiv preprint reduction has now been reported in two not yet peer reviewed reports (7 8) . In the NO-COVID group even if the first dose already induced a significant response, the boost vaccination was required to reach a response similar to that of the COVID after first dose. In this small study we did not find any relation of antibody nor T cell responses to Spike proteins with the total lymphocytes, their main subsets or the immunoglobulin levels. There was a trend of responses of antibody and T-cell responses to be lower in older patients (Supplementary figure 3) , no gender effect was detected. As mentioned above one of the NO-COVID patients, case 12, was treated with anti-CD20 for an autoimmune condition and did not develop IgG or IgM antibodies after vaccination. Interestingly a clearly measurable T-cell responses was detected (see Figure 2 tick case) after vaccination and a small expansion of circulating of plasmablasts in sequential samples. We detect plasmablast after the vaccine boost with few pre class switch B lymphocytes prior to vaccination despite anti-CD20 treatment, indicating residual capacity of the B cell compartment (Supplementary figure 4) . Another NO-COVID group patient, case 19, was infected the same day that received first dose of vaccination. The patient developed T cell response in the IGRA assay, and in this case, in addition to antibodies to the S antigen, she developed antibodies to N antigen (Figure 1 A, dot with asterisk), but the response was like the NO-COVID group indicating that being primed by two simultaneous stimuli did not result in this case in a supranormal response. We have studied in parallel antibody and cellular response to the BNT162b2 mRNA COVID-19 vaccine in a small group of HCW and found that the IGRA assays yields rapid results that are concordant with antibody tests and could constitute a valuable contribution to the evaluation on the immune response in people that may need to be reassured of being protected to SARS-CoV2 infection. This is however a pilot small study that should be expanded to really demonstrate that SARS-CoV-2 Spike IGRA based tests can constitute valuable correlates of protection complementary to serology. It has already been shown that protein N is the most immunogenic structural protein and that IgG responses to protein S in SARS-CoV-2 are lower, possibly due to the glycosylation state of this protein (9) . This may explain that IGRA and IgG(S) antibody tests were negative in two of All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 5, 2021. ; https://doi.org/10.1101/2021.03.31.21254472 doi: medRxiv preprint the participants in the COVID group that were IgG (N) positive. However, after immunization with a single dose, they responded to a level higher than fully vaccinate no COVID participants. There are a good number of studies demonstrating T cell responses to SARS-CoV-2 using technique widely applied to measure responses to other viral infection (10, 11) . These techniques include intracellular cytokine staining (ICS) by flow cytometry and variations of the ELISPOT assay which measure mainly IFN-gamma production. Activation-induced markers (AIM), also by flow cytometry, can be a sensitive technique (12) . However, they have limitations in the applicability compared with whole IGRA blood assays used here when it comes to use them in a clinical laboratory (13) . Availability of a complementary correlate of protection in addition to serology may be invaluable for to two groups, 1) HCW and other professionals with vulnerability factors that need to be reassured of being immunized to SARS-CoV2 before reassuming tasks that have a risk of accidental re-exposure and 2) for immunosuppressed patients that fail to make a measurable antibody response. IGRA Spike peptides test may constitute a very valuable tool in this context as can be applied to a large number of samples producing results in 24h and with promising sensitivity and specificity. Figure 1 . Significance of the differences, *p<0.05, **p<0.01, ***p<0.001, ****p<0.0001. All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 5, 2021. and ELISA (E & F). Patient 12 () and patient 19 (*) are labelled by red symbols. All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 5, 2021. All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted April 5, 2021. ; https://doi.org/10.1101/2021.03.31.21254472 doi: medRxiv preprint COVID-19 and the Path to Immunity Antigen-Specific Adaptive Immunity to SARS-CoV-2 in Acute COVID-19 and Associations with Age and Disease Severity Antibody Status and Incidence of SARS-CoV-2 Infection in Health Care Workers COVID-19 vaccines: comparison of biological, pharmacological characteristics and adverse effects of Pfizer/BioNTech and Moderna Vaccines Extended immunophenotyping reference values in a healthy pediatric population Age-specific pediatric reference ranges for immunoglobulins and complement proteins on the Optilite TM automated turbidimetric analyzer Differential effects of the second SARS-CoV-2 mRNA vaccine dose on T cell immunity in naïve and COVID-19 recovered individuals T-cell and antibody responses to first BNT162b2 vaccine dose in previously SARS-CoV-2-infected and infection-naive UK healthcare workers: a multicentre, prospective Analysis of the SARS-CoV-2 spike protein glycan shield reveals implications for immune recognition SARS-CoV-2-Specific Cell-Mediated Immunity in Kidney Transplant Recipients Recovered from COVID-19 Alain Duhamel, Myriam Labalette et al. Severe SARS-CoV-2 patients develop a higher specific T-cell response Targets of T Cell Responses to SARS-CoV-2 Coronavirus in Humans with COVID-19 Disease and Unexposed Individuals A whole blood test to measure SARS-CoV-2-specific response in COVID-19 patients The authors want to express their gratitude to participants of the study and laboratory technicians from Microbiology and Immunology for technical assistance. We thank Qiagen and Diasorin for commercial kits donation, these companies do not participate in the experimental plan, data analysis nor in writing this manuscript. English writing support was provided by Fidelma Greaves.This study was funded in part by Instituto de Salud Carlos III, grant COV20/00416 co-financed by the European Regional Development Fund (ERDF). The authors declare that they have no conflict of interest. All the authors have read and approved the text submitted.