key: cord-0986106-jxdhqvda authors: Khoo, Deborah; Yen, Ching Chiuan; Chow, Wai Tung; Jain, Pravar; Loh, Ne-Hooi Will; Teo, Wei Wei; Koh, Calvin title: Ultra-portable low-cost improvised powered air-purifying respirator: feasibility study date: 2020-05-07 journal: Br J Anaesth DOI: 10.1016/j.bja.2020.04.082 sha: 697c7f68b607efa4ca9d96e3c5147be514ed28a8 doc_id: 986106 cord_uid: jxdhqvda nan printed adaptors. This was tested using an adapted version of the National Institute for Occupational Safety and Health (NIOSH) guidelines for PAPR. 7 The overall concept was to link an actuator to a High Efficiency Particulate Air (HEPA) filter and a fullface snorkel mask via 3D printed adaptors. (Figure 1 ) The total weight is 800 g. We tested our concept using the Subea Easybreath TM snorkeling mask by Decathalon (manufacturer, location) for its reasonable pricing, quality, sizes, full-face protection, silicone seal and option of lens inserts. We chose Medtronic mechanical DAR™ ventilator filters (manufacturer, location) for their widespread use in hospitals, and bacterial and live viral filtration efficiency of > 99.99999%. The Heat Moisture Exchanger (HME) electrostatic HEPA filter version may incur undue airflow resistance from the non-filtering HME portion. A commercially available, inexpensive, and portable centrifugal DC blower fan (Model 9BMB12P2F01, Sanyo Denki, location) was used. Operating at 12 V and a power rating of 10.8 W, this actuator achieves peak post-filter airflow of > 30 L min -1 with the impeller rotating at 4500 RPM, generating a maximum noise of 56 dB. It has a small footprint of 9.5 cm x 9.7 cm x 3.3 cm (height x depth x width) and weighs 190 g. A portable 12 V Lithium ion (Li-ion) rechargeable battery with a 9800 mAh capacity and dimensions of 13 cm x 6.7cm x 2.3 cm (height x depth x width) was selected to provide a battery life of > 10 h. Ducted 3D printed adaptors interfaced with the mask's air inlet to concentrate the actuator output into the mask. Acrylonitrile Butadiene Styrene (ABS) filament was used for its durability, strength, and limited flexibility. Total cost of the prototype device was £107 (mask £17, battery £45, actuator £28, 3D printed parts £17). In comparison, conventional PAPR can cost £600 to £2000. The study subjects comprised 7 clinicians working in a public hospital that manages COVID-19 patients. A National Healthcare Group Domain Specific Research Board waiver was obtained. Subjects first performed a fit test to determine best-fit. We assumed some degree of air leakage, hence are not classifying it as a tight-fit mask, neither is it loose-fitting. Second, a battery, airflow and HEPA filter check was performed. A performance evaluation of breath gas concentrations was carried out. Per the NIOSH Certification Standards for Human Testing of PAPR, 7,9,10 we monitored peripheral capillary oxygen saturation (SpO 2 ), respiratory rate (RR), inspired concentration of oxygen (FiO 2 ) and carbon dioxide ( User evaluation -There were no adverse symptoms reported when the actuator was on. On a scale of 1-5 (1-least favourable, 5-most favourable), subjects gave the following mean scores: ease of assembly -4.4; ease of wear -4.3; comfort -3.7; noise level -3.4; weight -3.6; subjective safety -4. We propose this adaptation as a potential low cost and ultra-portable PAPR device, which may help ameliorate supply shortages and provide healthcare workers exposed to aerosol-generating procedures with additional protection. The airflow rate of this mask needs improvement, but we note the NIOSH criteria are written for high intensity industrial and mining use, not specific to healthcare, where the activity, environment and workload differs. Rational use of personal protective equipment (PPE) for coronavirus disease (COVID-19): interim guidance. Geneva: World Health Organization 9 Occupational health aspects of emerging infections -SARS outbreak affecting healthcare workers The Occupational Risk of Influenza A (H1N1) Infection among Healthcare Personnel during the 2009 Pandemic: A Systematic Review and Meta-Analysis of Observational Studies The changing face of healthcare worker perceptions on powered air-purifying respirators during the SARS outbreak Determination of facepiece carbon-dioxide and oxygen concentration levels of tight-fitting powered air-purifying respirators with the blower unit running Proposed Concept: Powered Air-Purifying Respirator (PAPR) Standard Subpart P RR Respiratory Rate SpO2 peripheral capillary oxygen saturation FiO2 Inspired concentration of oxygen FiCO2 Inspired concentration of carbon dioxide, ETCO2 end tidal carbon dioxide This project was a collaboration between the Departments of Anaesthesia and the Division of Industrial Design, School of Design and Environment, National University of Singapore. The authors declare that there are no financial conflicts of interest. Initiative. Any opinions, findings and conclusions or recommendations expressed in this material are those of the authors and do not reflect the views of the National Research Foundation, Singapore.