key: cord-0985018-u71x01v2 authors: Pandey, Lokesh K.; Singh, Virendra V.; Sharma, Pushpendra K.; Meher, Damayanti; Biswas, Utpal; Sathe, Manisha; Ganesan, Kumaran; Thakare, Vikas B.; Agarwal, Kavita title: Screening of core filter layer for the development of respiratory mask to combat COVID-19 date: 2021-05-13 journal: Sci Rep DOI: 10.1038/s41598-021-89503-x sha: 71c9a735f6d290d17d9dbc6cd04aae8a7abec17e doc_id: 985018 cord_uid: u71x01v2 The severe outbreak of respiratory coronavirus disease 2019 has increased the significant demand of respiratory mask and its use become ubiquitous worldwide to control this unprecedented respiratory pandemic. The performance of a respiratory mask depends on the efficiency of the filter layer which is mostly made of polypropylene melt blown non-woven (PP-MB-NW). So far, very limited characterization data are available for the PPE-MB-NW in terms to achieve desired particulate filtration efficiency (PFE) against 0.3 µm size, which are imperative in order to facilitate the right selection of PP-MB-NW fabric for the development of mask. In present study, eight different kinds of PP-MB-NW fabrics (Sample A–H) of varied structural morphology are chosen. The different PP-MB-NW were characterized for its pore size and distribution by mercury porosimeter and BET surface area analyzer was explored first time to understand the importance of blind pore in PFE. The PP-MB-NW samples were characterized using scanning electron microscopy so as to know the surface morphology. The filtration efficiency, pressure drop and breathing resistance of various PP-MB-NW fabric samples are investigated in single and double layers combination against the particle size of 0.3, 0.5 and 1 µm. The samples which are having low pore dia, high solid fraction volume, and low air permeability has high filtration efficiency (> 90%) against 0.3 µm particle with high pressure drop (16.3–21.3 mm WC) and breathing resistance (1.42–1.92 mbar) when compared to rest of the samples. This study will pave the way for the judicial selection of right kind of filter layer i.e., PP-MB-NW fabric for the development of mask and it will be greatly helpful in manufacturing of mask in this present pandemic with desired PFE indicating considerable promise for defense against respiratory pandemic. A new outbreak of corona virus disease (COVID- 19) , a viral contagious infection has engulfed many life globally and remain persist as major global threat to the human beings 1 . The disease is caused by infection with the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and primary transmission is through virusfilled respiratory aerosol droplets and can be produced by an infected person when coughs, sneezes, speaks or breathes, though specific mode of transmission is still debatable [2] [3] [4] [5] . These aerosol droplets are having a different aerodynamic sizes, the droplet which has aerodynamic diameter more than 5 µm settles due to gravity near the source and hence, it reduces the chances of spread, however the fine aerosol particle having aerodynamic size less than 5 µm remain suspended in the environment for longer duration and play a key role for the spreading of infection 6 . Though the ultimate fate of aerosol particles are greatly influenced by the various environmental factors such as humidity, temperature, etc. which determine the virulence of aerosol particle 2 . In the past also world has witnessed many deadliest outbreak including cholera, Spanish flu, Ebola etc. and now corona outbreak has raised a serious threat for human life and emerged as a major challenge for the scientific fraternity to control its widespread infection 7 . The World Health Organization (WHO) on March 11, 2020 declared that the COVID-19 is a pandemic and had endangered more than 218 countries and territories affecting more than 6.4 crore human life around the world and the sustained risk of further global spread 8 . Government regulatory authorities are working on the World Health Organization's (WHO) guidelines and has taken a protective measure to prevent this world disaster unleash spread of deadliest corona pandemic by advancement in sanitization and public hygiene and take a serious measures in terms of isolation, quarantines etc. along with the use of appropriate personal protective equipment for healthcare workers in practice 9, 10 . Amidst the lack of vaccine against this COVID-19, personal hygiene and use of facemask have been suggested where, G = mass per unit area, P f = fiber density (g/cm 3 ), and Z = thickness of the fabric, mm. Fabric's areal density (mass per unit area) was measured according to ASTM D3776-09 standard. Each specimen was cut into 5 cm 2 size using a template and weighed by an electronic balance. where, ρ is areal density (g/m 2 ), m is the mass in g and A is the fabric area in m 2 . Five measurements were conducted for each PP-MB-NW fabric. To determine the particular filtration efficiency of different PP-MB-NW, a specimen of 3.14 cm 2 area was taken from the PP-MB-NW samples by considering the surface area of a typical facemask as approximately 150 cm 2 as reported elsewhere 33 . Based on the area of mask, flow rate was calculated for particular specimen and it was 4.5 LPM, representative of 95 LPM. Three samples of each PP-MB-NW were tested for its filter performance. From the mean penetration value, the percentage efficiency was calculated for each melt blown individual and combination thereof. Determination of particulate filtration efficiency. Figure 1 illustrate the role of various layers of respiratory mask against different particle size with emphasis to core layer i.e. PP-MB-NW against most penetrating particle size of 0.3 µm. The filtration efficiency and pressure drop of PP-MB-NW was tested by using NaCl test rig 34 . The schematic view of the NaCl Test Rig is given in Fig. 2 . The test rig consists of the compressor, air receiver, dry air unit, flow meter, control valve, air ducts, aerosol generator, particle counter, and digital manometer etc. as shown in Fig. 2 . The dry and clean air was obtained from compressor through HEPA filter and fed to the air regulator. The required airflow is adjusted by means of flow meter and flow control valve. NaCl was used to generate aerosol and the size of aerosol ranging from 0.3 to 10 μm. The test aerosol of NaCl is generated by compressed air atomisation using glass nebuliser. The generator/pump when operated at an air pressure of 1.76 kg cm 2 (approx) ensures production of NaCl aerosol in the sub micron range with Mass Median Diameter (MMD) of 0.3 μm. The PFE of different PP-MB-NW was measured by laser particle counter by taking the difference of particles from up and down air stream of respiratory mask 35 . The air filtration efficiency is calculated using following equation: where C1 is the number of NaCl particle in upstream counts and C2 is the number of NaCl particle in downstream counts. Influence of structural characteristics of PP-MB-NW fabric. In order to know the effect of structural characteristics of PP-MB-NW fabric on filtration PFE, structural characteristic such as thickness, areal density and solid volume fraction (α) were studied and tabulated in Table 1 17, 36, 37 . Areal density is an important factor which affects the fluid flow through a nonwoven and it also affects the air permeability 38 . Areal density is also affected by thickness and density of the fibers and finally affects the α 37 . Hence, all these structural parameters are interrelated. As can be seen from the Table 1 the areal density and thickness of the PP-MB-NW samples A-H were varied from 18-60 GSM and 0.08-0.350 mm, respectively. Since, thickness and areal density in combination has ability to affect α or porosity of a fabric. Therefore, α which is also referred as packing density of the fabric are also calculated and showed in Table 1 . The α values of samples A-H are calculated and found that it varied from 1980 to 3700. In general, as the areal density increases the α value should also increase, however in this study, regular trend is not observed due to difference in thickness (increase in thickness decreases the α value). However, In sample A and C, the α is at higher side from rest of the samples which reflects the greater degree of compactness of the fabric due to high packing density which could decreases the air permeability and (1) www.nature.com/scientificreports/ in turn increases the filtration efficiency 39, 40 . Hence, from the above data it can infer that the sample A and C may have lower air permeability with high filtration efficiency 41 . There is limited research on the effect of PP-MB-NW fabrics thickness, solid volume fraction and porosity over air permeability of non woven structure in technical textiles 42 . In general, it has been reported by some of research group that there is a non linear relationship between air permeability and thickness and solid volume fraction 43, 44 , though it has also been found that air-permeability is almost inversely proportional to the mass per unit area 45 . However, it is rational to expect that air permeability is strongly dependent on non woven microstructural parameters such as porosity, fiber size, solid volume fraction and fiber arrangement as air permeability governs the air resistance or the pressure drop of the air through fabric 36, 46 . In general, respiratory mask is comprised of layers, from outer to inner: an outer hydrophobic layer spun bound followed by 2 melt blown non woven layer (PP-MB-NW) as a filter layer, in between the filter layer, one support layer that provides rigidity and adds thickness to the mask, giving it more structure and adding to the feel of comfort. The innermost layer is another hydrophobic non-woven polypropylene layer which minimizes moisture within the mask from entering the mask material. The air permeability and pressure drop of PP-MB-NW samples (A-H) were measured according to ASTM D73 47 . As can be seen from the Fig. 3 and Table 2 the air permeability of sample A to D is varying from 197.24 to 345.84 l/m 2 /s in single PP-MB-NW samples while in combination of double layer it varied from 86.67 to 213.17 l/m 2 /s. While in sample E to H air permeability increased from 477.04 l/m 2 /s to 1060.76 l/m 2 /s in single layer and in double layer it increases from 257.09 to 535.80 l/m 2 /s. As it is observed from Fig. 3 , as air permeability increases, pressure drop decreases as it is inversely proportional to the air permeability. This difference in air permeability and pressure drop is due to meltblown technology which enables production of webs having finer fibers with higher surface area, and different degree of interlacing. The decrease in air permeability using 2 melt blown layer is attributed by multilayered structures behaved as a barrier to hinder the flow of air through the structure. The differences in air permeability of the samples are may be due to differences in pore sizes and compactness of these samples. As can been seen from the Table 2 , samples A to C are having lower air permeability when compared to rest of the samples and small difference in air permeability of the samples, one can expect that there may be a small variation in pore size, compactness and interlacing in between fibers and may have little variation in PFE 48, 49 . The above findings are well supported by solid volume fraction of the various PP-MB-NW samples. As in sample A and B the α value was greater than rest of the samples. In order to get more www.nature.com/scientificreports/ insight of packing density, fiber diameter, degree of entanglements and distance between the fibers which can greatly influence the air permeability of PP-MB-NW fabrics, it was further characterized for its surface morphology using SEM in subsequent section. PP-MB-NW samples was measured using the NaCl aerosol method as a function of particle size. Prior to the experiment, samples are conditioned for a minimum of 24 h by exposure to a temperature of 25 ± 1 °C and a relative humidity of 85 ± 5% 30 . The samples are allowed to return at room temperature for at-least 4 h between exposure and prior to subsequent testing. The filtration efficiency of the samples has been tested for the particle size of 0.2 µm, 0.3 µm, 0.5 µm and 1 µm. The reason to choose 0.3 µm size particle for PFE is to target the respiratory droplet of Sars-COV-2 coronavirus which is larger than 0.3 µm. The concentration of the upstream and downstream particles of sizes 0.2 µm, 0.3 µm, 0.5 µm and 1 µm were measured using the optical laser particle counter. In order to determine PFE, stabilization of generated aerosol particle size 0.3 µm, 0.5 µm and 1 µm is very important and it was studied for a period of 10 min as given in Fig. 4 . As can be seen from the Fig. 4 , the generated NaCl particle of different sizes are stable and observed approximately same number of particles. After stabilization of generated aerosol particle, the samples are challenged for three particle sizes of 0.2, 0.3, 0.5 and 1 µm. The aerosol generator can be adjusted to generate the desired concentrations of particle for testing, which are enumerated using the particle counter downstream of the test sample. The aerosol was passed through a drying chamber, diluted to the required concentration using pre filtered air and then passed through the sample. The challenge flow was same as reported in IS 9473:2002. Three replicate of each PP-MB-NW filter layer were tested at ambient experimental condition. The PFE of individual PP-MB-NW layer and their combination was determined as a function of particle size by measuring the upstream concentration and downstream concentration. Table 3 details the results obtained with the individual and its combination of PP-MB-NW layer for PFE, Differential Pressure (∆P) and breathing inhalation resistance (BIR). The ∆P and BIR across PP-MB-NW layer was measured to determine the comfort level of wearer and the suitability of materials to fabricate the mask. Table 3 , for 0.2 µm size particle the PFE is approx same as 0.3 µm and similar trend was reported earlier. Higher PFE values were obtained with sample A to C which may be due to highly compact structure of MB with higher degree of entanglement which may lead to decrease in pore dia and distance between fabrics, this results are in agreement with α value of Table 1 . Moreover, this wide variation in filtration efficiency for different samples can be attributed by the surface properties of the fibers which play a major role on filtration and the fibers in each layer of non woven fabric and its surface morphology is responsible for filtration performance. The value of ∆P and BIR of the samples are having high PFE are more when compared to samples (D-H) are having a low PFE, nevertheless the values are in the limit of IS 9473:2002. The ∆P and BIR value also support the compactness and high degree of entanglement of PP-MB-NW fabric in sample A-C. In order to further understand the filtration efficiency behavior of different PP-MB-NW samples, pore size, BET surface area analysis and SEM characterization studies were performed and discussed in subsequent sections. Pore size determination using mercury porosimeter. The pore structure and its size plays a very crucial role in performance of PP-MB-NW fabric making this as a most important structural feature 50 . These pore structure is internally connected by three-dimensional network of capillary channels of non-uniform dimensions. In PP-MB-NW fabric fabrics, pore can be classified into three categories namely blind pores, through pores and closed pores. The blind and through pores are playing significant role in PFE. In order to confirm the above finding, mercury porosimeter was used to determine the pore size of different samples 51 . In general pore size decreases due to higher specific surface area of lower fiber diameter 49 . The porosimeter determines both pressure and flow and record these in a pressure versus flow graph for wet and dry sample [51] [52] [53] . The dry data curves are determined after all the liquid expelled from the pores. These dry curves become the reference for calculating the pore distribution [51] [52] [53] . After measuring the pressure, air flow rate for dry and wet samples, pore size, and pore size distribution are calculated by the software. The results of mercury porosimeter are shown in Fig. 6 and summarized in Table 4 . Figure 6 shows the curve between pore size distributions versus the pore diameter in order to elucidate the major contribution of pores in filtration efficiency as pore size plays a very crucial role. Table 4 depicts the pore size distribution of various samples of PP-MB-NW fabric in terms of maximum pore size and mean pore size. As can be seen from Fig. 6 , in sample A-C, the pore size showed a relatively narrow range, the mean and maximum pore sizes were varied from 8.80 to 10.51 µm and 12.49 to 18.65 μm, respectively. In sample A, the largest peak exists of 9.5-10.0 µm and some major peak between the pore size from 9 to 10 µm, indicating maximum contribution of 9.0-10 µm pore diameter the most to the porosity followed by other pore diameter. In (Fig. 6) , largest peak of pore size diameter start from 8.4 to 9 μm, and it contribute most of the porosity in the sample. Likewise in sample C, D, E, F, G and H the most contributing pore diameters are 10-11 µm, 11.5-13.0 µm, 13-15 µm, 14-15.5 µm, 18-19.5 µm and 30-32 µm , respectively. As can be seen from the above, there is an increasing trend in pore diameter from sample A to H and similar tends are also observed in the air permeability from sample A-H. This increment in mean pore size was also supported by solid volume fraction and air permeability data shown in Tables 1 and 2 , respectively. Furthermore, PFE behaviors of different PP-MB-NW samples (A-H) are also supported by the above data, as fiber diameter plays a significant effect on filtration efficiency properties. Low fiber diameter leads to better filtration efficiency owing to higher entanglement and higher surface area as observed in case of samples A-C. This data also confirmed that the air permeability is inversely proportional to mean pore dia of the nonwoven PP, as reported elsewhere 38 . Moreover, the difference in maximum pore size and mean pore size of the samples are attributed by the influence of sample material, surface morphology, operation process and the use of wetting agent 54 . BET surface area characterization of PP-MB-NW. Using mercury porosimeter, the through pore diameter can be only measured up to the range of micron size only. However, the smaller pore diameter including blind pore cannot be characterized by utilizing mercury porosimeter as these pores are not accessible by the fluid to flow through them. Hence, the size of blind pore cannot be determined. In order to understand the PFE behavior sometime porosimeter and air permeability data along with microstructures details above are not sufficient enough to characterize the MB for its behavior. Hence, BET surface area analyzer was used to characterize and overcome the above limitation of porosimeter as blinds pores are also responsible for filtration efficiency. In order to understand and to get more insight in particular, the pore sizes which are below the limit of porosimeter, pore having a dimension between 17-3000 Å and total area in pore 11.79 Å were calculated. As can be seen from the Table 5 , the sample A and B the total area of pores 11.79 Å are more than 20 m 2 /g with BJH desorption Cumulative volume of pores between 17.0 Å and 3000 Å width approx more than 0.031 cm 3 /g are having good filtration efficiency. The resultant data from above characterization (role of structural characteristic, Fig. 7G,H) , and only representative figure are presented here. As can be seen from the Fig. 7A ,B (magnified image) which belong PFE to the range of 90-99, the rod shaped fibrous structures with non-uniform morphology was clearly observed with a wide range of diameters varied from 1 to 10 μm of PP-MB-NW fibers with a high degree of entanglement with each other. The diameters of individual fibers in a web appear to change along the length of the fibers. The fiber junctions were also visible which was produced from thermal sticking, interlacing and branching of MB fibers. Compactness between the fibers decreases as we move down from sample C to H. The fibers entanglement in sample A, B and C are more when compared to rest of the sample which reflects the decrease in pore size of fibers due to entanglement 49 . Furthermore, in case of larger diameter fibers, the chances of entanglement are relatively lower and this contributes larger distances between fibers and also leads to larger diameter fibers 49 . As can be seen from Fig. 7G ,H (magnified image) which belong to filtration efficiency of 20-30%, less fibers per unit area which increase the distances between fibers. Though the fiber diameter is less in Fig. 7G ,H as compared to rest of the sample, yet PFE is low due to low and wide spinneret orifice distributions which lead to increase the distance between the fibers during the manufacturing. Hence, it can be concluded from SEM images that PP-MB-NW fabrics which are having high entanglement, high fibers per unit area and the reduced distance between the fibers lead to higher filtration efficiency and this data support the findings of PFE and air permeability . In order to find out the effect of PP-MB-NW charge on filtration efficiency, resistance of sample A to H were measured utilizing Agilent 4339B, USA high resistance meter. The charge of various samples was calculated using resistance data. The charges of PP-MB-NW were shown in Fig. 8 and tabulated in Table 6 . From the Table 6 and Fig. 8 , it can be observed that there is a qualitative correlation between charge and filtration efficiency. From sample A to C the charge ranges from 30 to 31.78 nC which gives more than 95% PFE, while in samples D to H the decremented trend is observed for both charge and PFE. Hence, from the above data it can be inferred that higher the surface charge on PP-MB-NW will lead to higher PFE. However, this result is only qualitative in nature and only using this parameter it is difficult to conclude about the PFE. Therefore, PFE largely depends on the cumulative effect of microstructural parameters, electrostatic charge, air permeability, diameter of through pore, availability of closed pore etc. This study brings a useful insight to the selection of appropriate PP-MB-NW fabrics as effective air filter media, on the basis of their microstructural parameters such as porosity, pore diameter, fiber size, solid volume fraction, fiber arrangements, air permeability and pore size distribution. The filtration efficiency of different PP-MB-NW fabric samples is investigated in single and double layers combination for the particle size of 0.3, 0.5 and 1 µm. Surface area analysis was done for the first time in order to get more insight about the blind pore having a dimension between 17-3000 Å and total area in pore 11.79 Å which were not possible with mercury porosimeter and found that the PP-MB-NW fabrics having total area in pores 11.79 Å more than 10 m 2 /g with BJH desorption Cumulative volume of pores between 17.0 Å and 3000 Å width approx more than 0.031 cm 3 /g is exhibiting good filtration efficiency. The samples which are having the mean and maximum pore sizes in the range from 8.80 to 10.51 µm and 12.49 to 18.65 μm, respectively are having a good filtration efficiency. From the above data, it can be inferred that the PP-MB-NW fabrics those are having low pore dia, high solid fraction volume, low air permeability are having high filtration efficiency against 0.3 µm particle which reflects the importance of these structural parameters on PFE. Based on only one microstructural parameter, it is difficult to judge the performance of respiratory mask. However, the cumulative effect of these microstructural parameters which are interconnected with each other governs the performance of the PP-MB-NW fabrics in terms of filtration efficiency. We believe that this study will be very useful as it provides information and understanding about the core layer of respiratory mask, and provide a directive for the judicial selection of filter material to achieve high filtration efficiency to combat COVID-19. Filtration efficiencies of nanoscale aerosol by cloth mask materials used to slow the spread of SARS-CoV-2 Transmission of COVID-19 virus by droplets and aerosols: A critical review on the unresolved dichotomy Controversy around airborne versus droplet transmission of respiratory viruses: Implication for infection prevention Review of aerosol transmission of influenza A virus Infectious virus in exhaled breath of symptomatic seasonal influenza cases from a college community PowerPoint Presentation. US Department of Health and Human Services Infectious disease threats in the twenty-first century: Strengthening the global response The coronavirus outbreak is now a public health emergency of international concern -Here's what that means What has the COVID-19 pandemic taught us about adopting preventive measures? Public health measures to slow community spread of coronavirus disease 2019 Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1 Mask use during COVID-19: A risk adjusted strategy Considerations for wearing masks Testing the efficacy of homemade masks: Would they protect in an influenza pandemic? Face mask use in the general population and optimal resource allocation during the COVID-19 pandemic An overview of filtration efficiency through the masks: Mechanisms of the aerosols penetration Handbook of nonwoven filter media BRFSS 2006-Child Asthma Data Technical Information National Institute for Occupational Safety and Health. NIOSH guide to the selection and use of particulate respirators certified under 42 CFR Particle size-selective assessment of protection of European standard FFP respirators and surgical masks against particles-tested with human subjects Facemask shortage and the novel coronavirus disease (COVID-19) outbreak: Reflections on public health measures Face masks in the new COVID-19 normal: Materials, testing, and perspectives Composite Non-Woven Materials 164-210 Influence of rheology and surface properties on morphology of nanofibers derived from islands-inthe-sea meltblown nonwovens Multifunctional polymer composites produced by melt-blown technique to use in filtering respiratory protective devices Investigation of the physical properties of meltblown nonwovens for air filtration Design of electret polypropylene melt blown air filtration material containing nucleating agent for effective PM2.5 capture Respiratory protective devices -Filtering half masks to protect against particles -Requirements, testing, marking Studies on air permeability of multi-constituent nonwovens Advances in Technical Nonwovens A comparison of facemask and respirator filtration test methods A comparison of total inward leakage measured using sodium chloride (NaCl) and corn oil aerosol methods for air-purifying respirators Optical Particle Counting: Counting and Sizing The permeability of fibrous porous media Study on the relationship between structure parameters and filtration performance of polypropylene meltblown nonwovens Air permeability of polyester nonwoven fabrics Investigation on filtration properties of polyester needle-punched dust filter Influence of fiber diameter, fiber combinations and solid volume fraction on air filtration properties in nonwovens Simulating through-plane permeability of fibrous materials with different fiber lengths Development of needle-punched nonwoven fabrics from reclaimed fibers for air filtration applications A new method for pore structure analysis using air flow Prediction of single-layer fabric air permeability by statistical modeling A comparative study on air permeability properties of multilayered nonwoven structures Air Permeability of Nonwoven Fabrics (Master's thesis) Performance of fabrics for home-made masks against the spread of COVID-19 through droplets: A quantitative mechanistic study Multilayer fibrous filters with varied porosity and fibre diameter Porosity and barrier properties of polyethylene meltblown nonwovens Porous Media: Fluid Transport and Pore Structure Handbook of porous solids Characterization of the porous structure of a non-woven fibrous medium for air filtration at local and global scales using porosimetry and X-ray micro-tomography Characterization by mercury porosimetry of nonwoven fiber media with deformation A modification of the bubble-point method to determine the pore-mouth size distribution of porous materials Quality variables of meltblown submicron filter materials The authors thank Dr. D. K. Dubey, Director, Defence Research and Development Establishment, DRDO, Gwalior-474002 (India) for his keen interest and encouragement. DRDE Accession no. of this manuscript is DRDE/PD/27/2020. The authors declare no competing interests. Correspondence and requests for materials should be addressed to V.V.S.Reprints and permissions information is available at www.nature.com/reprints.Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.