key: cord-0984256-1w147c2r authors: Perng, Cherng-Lih; Jian, Ming-Jr; Chang, Chih-Kai; Lin, Jung-Chung; Yeh, Kuo-Ming; Chen, Chien-Wen; Chiu, Sheng-Kang; Chung, Hsing-Yi; Wang, Yi-Hui; Liao, Shu-Jung; Li, Shih-Yi; Hsieh, Shan-Shan; Tsai, Shih-Hung; Chang, Feng-Yee; Shang, Hung-Sheng title: Novel rapid identification of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) by real-time RT-PCR using BD Max Open System in Taiwan date: 2020-06-17 journal: PeerJ DOI: 10.7717/peerj.9318 sha: 05197f2d904fba4b6f267677edda9b1d43d95ef5 doc_id: 984256 cord_uid: 1w147c2r Coronavirus disease 2019 has become a worldwide pandemic. By April 7, 2020, approximately 1,279,722 confirmed cases were reported worldwide including those in Asia, European Region, African Region and Region of the Americas. Rapid and accurate detection of Severe Acute Respiratory Syndrome Virus 2 (SARS-CoV-2) is critical for patient care and implementing public health measures to control the spread of infection. In this study, we developed and validated a rapid total nucleic acid extraction method based on real‐time RT-PCR for reliable, high‐throughput identification of SARS-CoV-2 using the BD MAX platform. For clinical validation, 300 throat swab and 100 sputum clinical samples were examined by both the BD MAX platform and in-house real-time RT-PCR methods, which showed 100% concordant results. This BD MAX protocol is fully automated and the turnaround time from sample to results is approximately 2.5 h for 24 samples compared to 4.8 h by in-house real-time RT-PCR. Our developed BD MAX RT-PCR assay can accurately identify SARS-CoV-2 infection and shorten the turnaround time to increase the effectiveness of control and prevention measures for this emerging infectious disease. On December 31, 2019, a cluster of pneumonia cases of unknown etiology was reported in Wuhan, Hubei Province, China (Chan et al., 2020a) . Later, the Chinese Centers for Disease Control and Prevention (China CDC) reported a novel coronavirus as the causative agent of this outbreak, which was phylogenetically classified into a novel sister clade of SARS virus and named as the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The disease caused by this virus has been called as novel coronavirus disease 2019 . COVID-19 is an emerging whole world crisis issue. On March 11, 2020, the COVID-19 outbreak was characterized as a pandemic by the World Health Organization. By April 7, 2020, 72,614 fatalities and 1,279,722 laboratory-confirmed cases were reported globally (Centers for Disease Control & Prevention (CDC), 2020; Ghinai et al., 2020 ; World Health Organization (WHO), 2020; Wu & McGoogan, 2020) . A robust, sensitive, specific and high-throughput molecular detection method is urgently needed for SARS-CoV-2 diagnosis. Various methods for detecting SARS-CoV-2 have been reported, including real-time reverse transcription polymerase chain reaction (RT-PCR) and serological testing (Ai et al., 2020; Li et al., 2020b; Yu et al., 2020) . Currently, real-time RT-PCR is considered as the gold standard of diagnosis for SARS-CoV-2 because of its high sensitivity; this method can detect SARS-CoV-2 in various samples types, including oropharyngeal swab, sputum and blood Xie et al., 2020) . The BD MAX System (BD Diagnostic Systems, Franklin Lakes, NJ, USA) is an automated platform which nucleic acid extraction and real-time RT-PCR are performed on the same instrument. This BD MAX System offers not only FDA-cleared panel assays but also an open system mode for user-developed tests (Hofko et al., 2014; McHugh et al., 2018; Stokes et al., 2019; Widen, Healer & Silbert, 2014) . This study was designed to develop a dual RT-PCR tests for detecting the E and RdRp genes of SARS-CoV-2 directly from clinical samples using the open system mode of the BD MAX instrument and compare the results to those obtained by the in-house real-time RT-PCR method used in our hospital. This study was approved by Institutional Review Board, Tri-Service General Hospital (TSGHIRB No.: C202005041), registered on 20 March 2020. Informed consent was obtained from patients who signed permission to participate. Throat swab (COPAN COVID-19 Collection & Transport Kits with Universal Transport Medium or Virus Transport Swabs 147C) (n = 300) and sputum (n = 100) samples were collected from patients with highly suspected travel or contact history in northern Taiwan. Positive control was used with patient's diluted positive RNA aliquoted into Eppendorf tube stored in −80 C (a range of Ct (threshold cycle) value 34 ± 2 for each run acceptance). Throat swabs were placed in 0.5 mL phosphate-buffered saline and mixed vigorously with a vortex mixer for 30 s to release the cells. Sputum was liquefied by adding an equal volume of 2% N-acetyl-L-cysteine in phosphate-buffered saline followed by incubation for 10 min. Total nucleic acid containing viral RNA was extracted from 0.3 mL of the throat swab supernatant or liquefied sputum, by using LabTurbo Viral nucleic acid extraction kits on a LabTurbo 48 automatic extractor (Taigen Bioscience Corp., Taipei, Taiwan). RNA was eluted with 60 µL of RNase-free water. The primer and probe sequences of the two target genes (E gene as the first-line screening target, followed by confirmatory testing with the RdRp gene) has been previously described (Corman et al., 2020) (Table 1 ). The 10× TCID 50 Equine arteritis virus (EAV) (DIA-EIC; Diagenode, Belgium) was added to extraction buffer for internal control of monitoring RT-PCR inhibitors (Ct value 32 ± 2 as acceptance level for each assay). All primers and probes were synthesized and provided by Tib-Molbiol (Berlin, Germany). All assays were performed under the same conditions with some modifications. A 20-mL reaction was prepared containing five mL of RNA, 10 mL of 2× SensiFAST Probe No-ROX One-Step mix (Bioline Reagents Ltd., London, UK), 400 nM of forward and reverse primers, 200 nM of probe, 0.2 mL of reverse transcriptase, and 0.4 mL of RiboSafe RNase inhibitor (Bioline Reagents Ltd., London, UK). Thermal cycling was performed as follows: reverse transcription for 10 min at 50 C, followed by 95 C for 2 min and then 50 cycles of 95 C for 5 s and 58 C for 30 s on a Rotor-Gene Q real-time PCR machine (Qiagen, Hilden, Germany). We optimized the BD MAX ExK TNA 3 total nucleic acid Extraction Kit on the BD MAX. The BD MAX uses sample buffer tubes containing 750 mL lysis buffer to which the maximal 500 mL primary sample can be added manually. We compared the in-housed SARS-CoV-2 real-time RT-PCR assay with BD MAX System open mode using the same primers, probe and RT-PCR reagents to detect the E and RdRp genes of SARS-CoV-2. The RT-PCR master mixture without primers & probe (15 mL of 2× SensiFAST Probe Table 1 Primer and probe sequences used in this study. Primer name Sequence (5′→3′) References Note: † Modified the degenerated sequence to fit the Wuhan strain at position 3 from R to A and position 12 from S to A changes marked with an underline. No-ROX One-Step mix, 0.3 mL of reverse transcriptase and 0.6 mL of RiboSafe RNase inhibitor) was added to the position 3 on BD cartridge (Fig. 1) . The volume of 2.5 mL of primers and probe mixture of E gene and RdRp + IPC gene was added to the position 2 and position 4. Finally, 12.5 mL eluted nucleic acid was added to position 3 and mix with RT-PCR master mixture. A total of 12.5 mL of above mixture was added to position 2 and mix with 2.5 mL E gene primers (2.4 pmole/mL) & probe (1.2 pmole/mL). Residual 12.5 mL mixture was added to position 4 mixing with 2.5 mL RdRp + IPC gene primers (2.4 pmole/mL) & probe (1.2 pmole/mL). The mixture in position 2 and 4 were transferred to TOP/BOTTOM PCR chamber (Fig. 1 ). We carried out the entire sample-toresult procedure in the BD MAX PCR Cartridges. Assay precision was determined by testing individual samples divided into five parts and extracted/assayed separately. The LDT SARS-CoV-2 real-time RT-PCR assay was used as the "gold standard" to assess the diagnostic performance of the BD MAX assay. The BD MAX assay hands-on time was estimated as the sum of the times required to complete sample preparation, device loading and cleaning and result review and reporting. The procedures used for the BD MAX System included sample preparation, device loading, total nucleic acid extraction, RT-PCR, and results interpretation. The hands-on time and turnaround time between the LDT and BD MAX System were compared (Fig. 2) . Use of the BD MAX System improved the turnaround time from 4.8 h to approximately 2.5 h with 24 samples processed simultaneously including prepare samples, clean and prepare rack, create worklist, and prepare MMK (master mix), while also decreasing hands-on time, reducing exposure risk. The BD MAX System can also provide The analytical specificity of SARS-CoV-2 E and RdRp gene detection by real-time RT-PCR as well as the cross-reactivity with other respiratory pathogens were determined previously (Corman et al., 2020) . Here, we focused on the clinical performance of detection using the BD MAX System. Five replicates of serial dilutions of SARS-CoV-2-positive samples and a negative template control were tested to evaluate the intra-and inter-assay reproducibility of the BD MAX assay ( Table 2 ). The reproducibility of the Ct values was satisfactory, showing a coefficient of variation of less than 10%. The empirical sensitivity of the BD MAX assay was determined by evaluating serial dilutions of positive samples and comparing the results to those of the LDT assay. As shown in Fig. 3 , diluted specimens were reliably detected by both assays, from the original titer to the 10 −3 titers. BD MAX assay detected four times in eight replicates in A total of 400 clinical samples were included in this study. Most samples were throat swabs (n = 300), followed by sputum (n = 100). Among the 400 samples, 28 samples were positive and 272 samples were negative for SARS-CoV-2 real-time RT-PCR with the LDT assay and BD MAX System. These 28 positive samples were further confirmed by Taiwan CDC central laboratory. Concordant results were obtained for both assays in SARS-CoV-2 detection, showing 100% agreement (Table 3 ). The Ct values of the positive specimens for SARS-CoV-2 (n = 28) were highly correlated in the comparison of the LDT assay and BD MAX System, with Spearman coefficients of 0.96 and 0.91, respectively (Fig. 4) . This is the first study of the performance of the SARS-CoV-2 detection assay using the BD MAX System. Compared to the in-house results and those from the reference laboratory, the SARS-CoV-2 assay on the BD MAX showed good performance. In this study, we successfully validated a rapid and high-throughput method on the BD MAX platform for accurately and reproducibly identifying SARS-CoV-2 with a greatly reduced turnaround time and fewer hand-on preparation steps including preparing ready-to-use tubes (e.g., 100 Rx without reverse transcriptase stored in −80 C). Several studies have reported that real-time RT-PCR gives false-negative results in detecting SARS-CoV-2 (Li et al., 2020a; Liu et al., 2020; Winichakoon et al., 2020) . Combining real-time RT-PCR testing with other clinical features is necessary to diagnose COVID-19 . Many detection methods have been used or reported for the diagnosis and/or surveillance of SARS-CoV-2 (Chan et al., 2020b; Corman et al., 2020; Wang et al., 2020b; Yang et al., 2020) , among which real-time RT-PCR is the most sensitive. Although this method is routinely used, it requires specialized interpretation and has a long turnaround time. The performance of Molecular BD MAX System for different pathogens has been evaluated previously (Leach et al., 2019; Stokes et al., 2019) . These studies demonstrate that the BD MAX System is a good diagnostic tool with a rapid turnaround time, enabling appropriate treatment decisions. During the writing of this manuscript, several molecular assays have been developed for detecting and identifying SARS-CoV-2, including the Cobas SARS-CoV-2 test (Roche, Basel, Switzerland) and TaqPath Covid-19 Combo Kit (Thermo Fisher Scientific, Waltham, MA, USA), which have been authorized for use by the US Food and Drug Administration. To overcome the SARS-CoV-2 pandemic, more sensitive and robust methods are required. Our designed BD MAX method had several advantages. First, the use of an automated platform with the same primers, probe and master mix as used in our manual LDT assay. Second, there was comparable accuracy, sensitivity and specificity and easy integration into the laboratory workflow. Third, our findings confirm the suitability of the BD MAX system for directly detecting SARS-CoV-2 from clinical specimens. Fourth, the laboratory-developed SARS-CoV-2 BD MAX assay is a dual assay for detecting both E and RdRp gene, allowing for screening and confirming of SARS-CoV-2 infection simultaneously. Fifth, the use of only one platform test in routine settings for the clinical diagnosis of emerging infectious agents in various clinical specimens, including sputum and throat swab samples. In summary, a SARS-CoV-2 real-time PCR molecular test was developed on the BD MAX System. This test showed excellent sensitivity and specificity and can be used to rapidly detect SARS-CoV-2 infection. Our SARS-CoV-2 test is also rapid and high-throughput, providing accurate and reproducible results with a significantly reduced turnaround time and fewer hands-on preparation steps. This method is very easy with less skillful requirements and can be implemented in emergency medical laboratories for only short training course. Chien-Wen Chen conceived and designed the experiments, authored or reviewed drafts of the paper, and approved the final draft. Sheng-Kang Chiu conceived and designed the experiments, authored or reviewed drafts of the paper, and approved the final draft. Hsing-Yi Chung performed the experiments, prepared figures and/or tables, and approved the final draft. Yi-Hui Wang performed the experiments, prepared figures and/or tables, and approved the final draft. Shu-Jung Liao performed the experiments, prepared figures and/or tables, and approved the final draft. Shih-Yi Li performed the experiments, prepared figures and/or tables, and approved the final draft. Shan-Shan Hsieh performed the experiments, prepared figures and/or tables, and approved the final draft. Shih-Hung Tsai conceived and designed the experiments, authored or reviewed drafts of the paper, and approved the final draft. Feng-Yee Chang conceived and designed the experiments, authored or reviewed drafts of the paper, and approved the final draft. Hung-Sheng Shang conceived and designed the experiments, performed the experiments, analyzed the data, prepared figures and/or tables, authored or reviewed drafts of the paper, and approved the final draft. The following information was supplied relating to ethical approvals (i.e., approving body and any reference numbers): Tri-Service General Hospital Institutional Review Board approved this research (TSGH IRB C202005041). The following information was supplied regarding data availability: Raw data are available in Data S1 and S2. Supplemental information for this article can be found online at http://dx.doi.org/10.7717/ peerj.9318#supplemental-information. Era of molecular diagnosis for pathogen identification of unexplained pneumonia, lessons to be learned Centers for Disease Control and Prevention (CDC). 2020. Coronavirus disease 2019 (COVID-19) in the U.S. Available at Improved molecular diagnosis of COVID-19 by the novel, highly sensitive and specific COVID-19-RdRp/Hel real-time reverse transcription-PCR assay validated in vitro and with clinical specimens A familial cluster of pneumonia associated with the 2019 novel coronavirus indicating person-to-person transmission: a study of a family cluster Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR Illinois C-IT. 2020. First known person-to-person transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the USA Detection of carbapenemases by real-time PCR and melt curve analysis on the BD max system A rapid and automated sample-toresult Candida auris real-time PCR assay for high-throughput testing of surveillance samples with the BD max open system False-negative results of real-time reverse-transcriptase polymerase chain reaction for severe acute respiratory syndrome coronavirus 2: role of deep-learning-based CT diagnosis and insights from two cases Development and clinical application of a rapid IgM-IgG combined antibody test for SARS-CoV-2 infection diagnosis Positive rate of RT-PCR detection of SARS-CoV-2 infection in 4880 cases from one hospital in Detection of norovirus by BD MAX TM , Xpert Ò norovirus, and xTAG Ò gastrointestinal pathogen panel in stool and vomit samples Multicenter clinical validation of the molecular BD max enteric viral panel for Perng Combination of RT-qPCR testing and clinical features for diagnosis of COVID-19 facilitates management of SARS-CoV-2 outbreak Detection of SARS-CoV-2 in different types of clinical specimens Laboratory evaluation of the BD MAX MRSA assay Negative nasopharyngeal and oropharyngeal swab does not rule out COVID-19 Characteristics of and important lessons from the coronavirus disease 2019 (COVID-19) outbreak in China: summary of a report of 72314 cases from the Chinese center for disease control and prevention Comparison of different samples for 2019 novel coronavirus detection by nucleic acid amplification tests Rapid detection of SARS-CoV-2 using reverse transcription RT-LAMP method Measures for diagnosing and treating infections by a novel coronavirus responsible for a pneumonia outbreak originating in Wuhan We acknowledge and thank technical personnel of BD Diagnostics, for her technical support. This study was supported by Tri-Service General Hospital, Taipei, Taiwan, ROC, Grant Numbers: TSGH-D-109142 and NDMC-NTHU-109-3. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. The following grant information was disclosed by the authors: Tri-Service General Hospital, Taipei, Taiwan, ROC: TSGH-D-109142 and NDMC-NTHU-109-3. The authors declare that they have no competing interests. Cherng-Lih Perng conceived and designed the experiments, performed the experiments, analyzed the data, prepared figures and/or tables, and approved the final draft. Ming-Jr Jian conceived and designed the experiments, performed the experiments, analyzed the data, prepared figures and/or tables, and approved the final draft. Chih-Kai Chang conceived and designed the experiments, performed the experiments, analyzed the data, prepared figures and/or tables, and approved the final draft. Jung-Chung Lin conceived and designed the experiments, authored or reviewed drafts of the paper, and approved the final draft. Kuo-Ming Yeh conceived and designed the experiments, authored or reviewed drafts of the paper, and approved the final draft.