key: cord-0984095-u19ojl8n authors: Hou, Sen-Kuang; Lin, Hui-An; Chen, Shao-Chun; Lin, Chiou-Feng; Lin, Sheng-Feng title: Monocyte Distribution Width, Neutrophil-to-Lymphocyte Ratio, and Platelet-to-Lymphocyte Ratio Improves Early Prediction for Sepsis at the Emergency date: 2021-07-28 journal: J Pers Med DOI: 10.3390/jpm11080732 sha: 96fba3afd6a503329a35745ad5102338a4119ca6 doc_id: 984095 cord_uid: u19ojl8n (1) Background: Sepsis is a life-threatening condition, and most patients with sepsis first present to the emergency department (ED) where early identification of sepsis is challenging due to the unavailability of an effective diagnostic model. (2) Methods: In this retrospective study, patients aged ≥20 years who presented to the ED of an academic hospital with systemic inflammatory response syndrome (SIRS) were included. The SIRS, sequential organ failure assessment (SOFA), and quick SOFA (qSOFA) scores were obtained for all patients. Routine complete blood cell testing in conjugation with the examination of new inflammatory biomarkers, namely monocyte distribution width (MDW), neutrophil-to-lymphocyte ratio (NLR), and platelet-to-lymphocyte ratio (PLR), was performed at the ED. Propensity score matching was performed between patients with and without sepsis. Logistic regression was used for constructing models for early sepsis prediction. (3) Results: We included 296 patients with sepsis and 1184 without sepsis. A SIRS score of >2, a SOFA score of >2, and a qSOFA score of >1 showed low sensitivity, moderate specificity, and limited diagnostic accuracy for predicting early sepsis infection (c-statistics of 0.660, 0.576, and 0.536, respectively). MDW > 20, PLR > 9, and PLR > 210 showed higher sensitivity and moderate specificity. When we combined these biomarkers and scoring systems, we observed a significant improvement in diagnostic performance (c-statistics of 0.796 for a SIRS score of >2, 0.761 for a SOFA score of >2, and 0.757 for a qSOFA score of >1); (4) Conclusions: The new biomarkers MDW, NLR, and PLR can be used for the early detection of sepsis in the current sepsis scoring systems. Sepsis, a life-threatening condition, is substantially associated with high morbidity and mortality in health care systems worldwide [1] [2] [3] [4] [5] [6] . Early diagnosis of sepsis, along with prompt initiation of treatment, can result in favorable outcomes [7] [8] [9] . Physicians in the emergency department (ED) who first encounter a patient in health settings should detect any sign of sepsis progression [10] . Currently, the recommended approach to sepsis is based on two definitions: (1) as per Sepsis-2 criteria published in 1992, sepsis is defined as documented infection in conjugation with a systemic inflammatory response syndrome (SIRS) score of ≥2 points [11] ; and (2) as per Sepsis-3 criteria published in 2016, sepsis is defined as a quick sequential organ failure assessment (qSOFA) score of ≥2 [12] followed by an acute change of ≥2 points in the SOFA score [13] due to the infection [14] . The complexity of the definition of sepsis and the absence of an effective biomarker impede the early diagnosis of sepsis in the ED. To date, numerous biomarkers such as interleukin-6 (IL-6), C-reactive protein (CRP), and procalcitonin (PCT), have been used for the early detection of sepsis [9, [15] [16] [17] . However, in real-world clinical practice, the advanced biomarkers are still limited. IL-6 is not readily available in ED. Despite more specific for bacterial infection [18] [19] [20] , PCT is not available in every first-level hospital, and its cost, around four times higher than CRP, is another concern [20] [21] [22] . Although CRP is widely available, the turnaround time (TAT) for CRP is longer than a routine CBC report (including MDW). Emergency physicians may order these tests based on the results of routine complete blood cell count (CBC) analysis performed using a hematology analyzer. Under most conditions, the TAT for clinical chemistry instrument is longer than TAT for hematology analyzer [23] [24] [25] . If a point-of-care testing of CRP was not available, this may cause a delay of early antibiotic use. Monocyte distribution width (MDW) is a new biomarker analyzed in conjugation with routine CBC in a hematology analyzer [9, 15, 26] . In the early stage of sepsis, the proliferation of white blood cells (WBCs), namely monocytes and neutrophils, acts as the host's first immune response against pathogens [27, 28] . Leukocytosis was observed to be associated with increased volume and heterogeneity in terms of MDW [9] . In addition, other biomarkers examined in a hematology analyzer, including neutrophil-to-lymphocyte ratio (NLR) [29] [30] [31] and platelet-to-lymphocyte ratio (PLR) [31] [32] [33] , are useful for the early diagnosis of sepsis. This study investigated whether MDW, NLR, and PLR, in conjugation with sepsis scoring systems, namely the SIRS, SOFA, and qSOFA, can aid in the early identification of sepsis during the first ED visit. This retrospective observational study, based on a prospective registry system, was conducted in Taipei Medical University Hospital, a major tertiary referral hospital with 750 beds in Taipei, Taiwan. Since 1 January 2020, all patients visiting our ED were registered in this prospective registry system. This registry system included information regarding patients' age, sex, vital signs, triaging level, and Glasgow coma scale (GCS) score on arrival to ED; laboratory testing data at ED; disease codes based on the International Statistical Classification of Diseases, Tenth Revision, Clinical Modification (ICD-10-CM); past history of medical comorbidities (including hypertension, diabetes mellitus, coronary artery disease, cerebrovascular disease, end-stage renal disease, pulmonary disease, and malignant disease); and disposition of ED patients (discharge or hospitalization to the general ward or intensive care unit). This study was approved by the Joint Institutional Review Board of Taipei Medical University (approval number: N201904066). The requirement of informed consent was waived by the aforementioned review board because anonymous and deidentified information was used in this study. Patients who were registered in the prospective registry system of ED between 1 January 2020 and 30 November 2020 were enrolled in this study. Inclusion criteria were as follows: (1) patients presenting to our ED with infectious diseases (medical record confirmed by the authors H-A Lin and S-K Hou), (2) examination of patients by ED physicians, and (3) completion of laboratory tests within 2 h after arrival to the ED. Exclusion criteria were as follows: (1) age < 20 years, (2) no definite diagnosis of infectious disease after the quality review of our data (conducted by the authors H-A Lin and S-K Hou), and (3) patients with no laboratory tests by using a hematology analyzer at the ED. The primary outcome was the early diagnosis of sepsis according to Sepsis-2 criteria. Patients with sepsis were defined as those having a documented infection and a SIRS score of ≥2 points based on the following parameters: (1) a body temperature of <36 • C or >38 • C, (2) a heart rate of >90/min, (3) a respiratory rate of >20/min or PaCO2 of <32 mmHg, and (4) a WBC count of <4000 or >12,000 cells/mm 3 (or with 10% bands). Our patients were categorized into 2 groups: sepsis and nonsepsis. In addition, all patients were scored using the qSOFA and SOFA scoring systems based on our registry data. As a secondary outcome, we examined early mortality within 3 days due to septic shock. Since 1 January 2020, MDW has been measured as a new biomarker for inflammation in Taipei Medical University Hospital. MDW was analyzed using a Beckman Coulter UniCel DxH 900 analyzer (Beckman Coulter Taiwan, Taiwan Branch), which is a quantitative, multiparametric, automated hematology analyzer. On this analyzer, monocytes were identified on the basis of individual cell volume, high-frequency conductivity, and laser-light scatter. MDW was calculated as the standard deviation of a set of monocyte cell volume values. In addition, NLR and PLR were calculated by dividing neutrophil and platelet counts by the lymphocyte count, respectively. Continuous and discrete variables are presented as the mean ± standard deviation and proportion (%), respectively. A 1:4 propensity score (PS) matching was performed between the sepsis and nonsepsis groups by matching age, sex, GCS score, triage level, and medical comorbidities. A standardized mean difference (SMD) of less than ±0.1 between the 2 groups was considered to be significant. Univariate and multivariate logistic regression models were employed to obtain the odds ratios (ORs) of predictors; sepsis versus nonsepsis (according to Sepsis-2 criteria) was used as the dependent variable, and the score of each sepsis scoring system (SIRS, SOFA, and qSOFA) and biomarkers (WBC, MDW, NLR, and PLR) were used as independent variables. To perform sensitivity analysis, we used 2 multivariate models: without and with implementing CRP, an inflammatory biomarker. The receiver operating characteristic (ROC) curve was plotted to estimate the c-statistics. Optimal cutoff points were obtained by calculating Youden's index (the point with the maximum value of sensitivity + specificity − 1). The integrated discrimination improvement (IDI) test [34] was used to compare the c-statistics between the 2 ROC curves. The Hosmer-Lemeshow test was performed to examine the goodness of fit. All statistical analyses were conducted using SAS version 9.4 (Cary, NC, USA). Statistical significance was defined as p < 0.05. A total of consecutive 19,792 patients visited the ED between January 2020 and November 2020. Of them, 8698 patients were diagnosed as having an infectious disease after the data quality review by our medical record auditing team. In accordance with "Sepsis-2" consensus criteria, patients with infectious disease were categorized into two groups: sepsis (n = 308) and nonsepsis (n = 8390; Table 1 ). The detailed etiologies of microorganisms in sepsis group were summarized in the supplemental file (Table S1 ). Before PS matching, age, GCS score, triage level, and the prevalence of hypertension, diabetes mellitus, coronary artery disease, cerebrovascular disease, and end-stage renal disease significantly differed between the two groups. After performing 1:4 PS matching, 296 and 1184 patients were included in the sepsis and nonsepsis groups, respectively. All the aforementioned demographic characteristics and medical comorbidity prevalence were similar between the 2 groups (SMD < ±0.1). The flow diagram of the study was shown (Figure 1 ). Data regarding the distribution and diagnostic performance of SIRS score at each point was shown (Tables S2 and S3 ). From 1 January 2020, and 30 November 2020, the COVID-19 was not a pandemic disease in Taiwan according to data from the Taiwan National Infectious Disease Statistics System. None of the patients enrolled in the study had the diagnosis of COVID-19, and no indigenous case during our study period was reported. Data regarding the distribution and diagnostic performance of SIRS score at each point was shown (Tables S2 and S3 ). From 1 January 2020, and 30 November 2020, the COVID-19 was not a pandemic disease in Taiwan according to data from the Taiwan National Infectious Disease Statistics System. None of the patients enrolled in the study had the diagnosis of COVID-19, and no indigenous case during our study period was reported. Table 2 presents the findings of univariate logistic regression models used for analyzing the predictive value of sepsis scoring system scores and biomarkers. The scores of all sepsis scoring systems, namely the SIRS, SOFA, and qSOFA, were found to be significant predictors of sepsis. After applying the optimal cutoff point for sepsis scoring system scores, a SIRS score of ≥3 (OR: 5.46, 95% CI: 4.11-7.26, p < 0.0001), a SOFA score of ≥ 3 (OR: 1.90, 95% CI: 1.46-2.46, p < 0.0001), and a qSOFA score of ≥ 2 (OR: 1.86, 95% CI: 1.30-2.64, p < 0.0006) remained as significant predictors. Among these sepsis scoring systems, a SIRS score of ≥ 3, a SOFA score of ≥ 3, and a qSOFA score of ≥ 2, exhibited the low sensitivity of 44.9%, 47.0%, and 17.6%, respectively for sepsis, and the high specificity of 87.0%, 68.2%, and 89.7%, respectively, for sepsis. In terms of laboratory tests, the biomarkers WBC, NLR, PLR, CRP, and MDW were all found to be significant predictors of sepsis. We applied the following optimal cutoff points: WBC > 12 × 103 cells/µL (OR: 3.38, 95% CI: 2.59-4.52, p < 0.0001), NLR > 9 (OR: 5.85, 95% CI: 4.43-7.73, p < 0.0001), PLR > 210 (OR: 3.12, 95% CI: 2.39-4.05, p < 0.0001), CRP > 3 mg/dL (OR: 4.82, 95% CI: 3.66-6.36, p < 0.0001), and MDW > 20 (OR: 2.77, 95% CI: 2.13-3.62, p < 0.0001). After applying the cutoff points, we observed moderate diagnostic accuracy with moderate levels of sensitivity and specificity (i.e., 60%-70%). We used three types of multivariate logistic regression models (incorporating a SIRS score of ≥3 in model 1, a SOFA score of ≥ 3 in model 2, and a qSOFA score of ≥2 in model 3) for predicting sepsis (Table 3 ). In all the models, each sepsis scoring system, NLR > 9 U and MDW > 20 U were found to be significant predictors. These models demonstrated moderate to high diagnostic accuracy (an AUC of 0.796 in model 1, an AUC of 0.761 in model 2, and an AUC of 0.757 in model 3). After adjustment for a CRP level of >3 mg/dL in these models, NLR > 9 U still remained a significant predictor but not MDW > 20 U. Abbreviations: CI, confidence interval; CRP, C-reactive protein; n, number; MDW, monocyte distribution width; NLR, neutrophil-tolymphocyte ratio; OR, odds ratio; PLR, platelet-to-lymphocyte ratio; qSOFA, quick sequential organ failure assessment; SIRS, systemic inflammatory response syndrome; SOFA, sequential organ failure assessment. * Statistical significance was defined at p < 0.05. We compared the performance of each scoring system in predicting sepsis. Model 1 without CRP and with CRP exhibited a low quality of model fit (without CRP, the Hosmer-Lemeshow test, p = 0.0137; with CRP, the Hosmer-Lemeshow test, p = 0.0182). Both models 2 and 3 without CRP and with CRP revealed a good quality of model fit. Both model 2 (IDI: 0.91, p = 0.1924) and model 3 (IDI: 0.70, p = 0.3202) showed no significant difference in diagnostic accuracy between models without and with CRP. The ROC curves for three types of multivariate logistic regression models of predicting sepsis were shown (Figure 2 Abbreviations: CI, confidence interval; CRP, C-reactive protein; n, number; MDW, monocyte distribution width; NLR, neutrophil-to-lymphocyte ratio; OR, odds ratio; PLR, platelet-to-lymphocyte ratio; qSOFA, quick sequential organ failure assessment; SIRS, systemic inflammatory response syndrome; SOFA, sequential organ failure assessment. * Statistical significance was defined at p < 0.05. We compared the performance of each scoring system in predicting sepsis. Model 1 without CRP and with CRP exhibited a low quality of model fit (without CRP, the Hosmer-Lemeshow test, p = 0.0137; with CRP, the Hosmer-Lemeshow test, p = 0.0182). Both models 2 and 3 without CRP and with CRP revealed a good quality of model fit. Both model 2 (IDI: 0.91, p = 0.1924) and model 3 (IDI: 0.70, p = 0.3202) showed no significant difference in diagnostic accuracy between models without and with CRP. The ROC curves for three types of multivariate logistic regression models of predicting sepsis were shown ( Figure 2 ). As the secondary outcome, we assessed whether these sepsis scoring system-based models could predict early mortality within 10 days (Table 4 ). In general, all these models demonstrated a high diagnostic accuracy. In multivariate models without CRP, MDW > 20 U remained a robust predictor of mortality. By contrast, MDW > 20 U did not predict mortality after adjustment for CRP. In addition, no significant difference in diagnostic performance was observed between models without CRP and with CRP. The ROC curves for three types of multivariate logistic regression models of predicting mortality were shown (Figure 3) . We constructed a new scoring system model for predicting sepsis (Table 5 ). In this model, a qSOFA score of >1, PLR > 210, and MDW > 20 U were assigned a score of 1 and NLR > 9 U was assigned a score of 2. This model showed moderate to high diagnostic accuracy with an AUC of 0.755 (95% CI: 0.726-0.784) and a good quality of model fit (the Hosmer-Lemeshow test, p = 0.3020). The optimal cutoff score of ≥2 exhibited a sensitivity of 77% (95% CI: 73.0%-82.4%), a specificity of 63.9% (95% CI: 61.1%-66.6%), and an OR of 6.16 (95% CI: 4.57-8.30, p < 0.0001). The ROC curve for this new simple scoring system was shown (Figure 4) . We constructed a new scoring system model for predicting sepsis (Table 5 ). In this model, a qSOFA score of >1, PLR > 210, and MDW > 20 U were assigned a score of 1 and NLR > 9 U was assigned a score of 2. This model showed moderate to high diagnostic accuracy with an AUC of 0.755 (95% CI: 0.726-0.784) and a good quality of model fit (the Hosmer-Lemeshow test, p = 0.3020). The optimal cutoff score of ≥2 exhibited a sensitivity of 77% (95% CI: 73.0%-82.4%), a specificity of 63.9% (95% CI: 61.1%-66.6%), and an OR of 6.16 (95% CI: 4.57-8.30, p < 0.0001). The ROC curve for this new simple scoring system was shown (Figure 4 ). Abbreviations: CI, confidence interval; CRP, C-reactive protein; n, number; MDW, monocyte distribution width; NLR, neutrophil-tolymphocyte ratio; OR, odds ratio; quick sequential organ failure assessment; PLR, platelet-to-lymphocyte ratio; qSOFA, quick sequential organ failure assessment; SIRS, systemic inflammatory response syndrome; SOFA, sequential organ failure assessment. * Statistical significance was defined at p < 0.05. † Exact logistic regression was used to estimate the OR. We constructed a new scoring system model for predicting sepsis (Table 5 ). In this model, a qSOFA score of >1, PLR > 210, and MDW > 20 U were assigned a score of 1 and NLR > 9 U was assigned a score of 2. This model showed moderate to high diagnostic accuracy with an AUC of 0.755 (95% CI: 0.726-0.784) and a good quality of model fit (the Hosmer-Lemeshow test, p = 0.3020). The optimal cutoff score of ≥2 exhibited a sensitivity of 77% (95% CI: 73.0%-82.4%), a specificity of 63.9% (95% CI: 61.1%-66.6%), and an OR of 6.16 (95% CI: 4.57-8.30, p < 0.0001). The ROC curve for this new simple scoring system was shown (Figure 4 ). Abbreviations: CI, confidence interval; MDW, monocyte distribution width; NLR, neutrophil-to-lymphocyte ratio; OR, odds ratio; PLR, platelet-to-lymphocyte ratio; qSOFA, quick sequential organ failure assessment. * Statistical significance was defined at p < 0.05. The findings of this study indicated that the new inflammatory biomarkers, namely MDW > 20, NLR > 9, and PLR > 210, in conjugation with scoring systems, increased the diagnostic accuracy for early sepsis. In addition, we developed a simple 5-point model that involved a qSOFA score of >1 along with MDW > 20, NLR > 9, and PLR > 210; this model could differentiate between patients with and without the need of early antibiotics. Since 2012, the early goal-directed therapy as per Sepsis-2 criteria had emphasized the benefit of antibiotic use in the first hour after severe sepsis or septic shock impressed [35] . Every hour of delay in antibiotic administration was significantly associated with an increased mortality [36] [37] [38] . Early use of proper antibiotics can be accomplished through prompt and correct diagnosis of sepsis. This new model can help physicians recognize sepsis during the patient's first ED encounter. At an early stage of sepsis, monocytes exhibit morphological changes and heterogeneity in size [39] [40] [41] . MDW can indicate morphological variations in monocytes and serve as a novel inflammatory biomarker [9, 42, 43] . Crouser et al. demonstrated early septic patients can be confirmed in the initial 12 h of ED arrival with the elevated MDW [9, 44] . The time course of biomarkers after pathogen exposure in blood usually follows by (1) leukocytosis (such as count, morphological change of WBC), (2) inflammatory cytokines (such as IL-6, TNF-α), (3) inflammatory proteins (such as CRP, PCT), (4) poor perfusion-related markers (low pH, lactate), and (5) coagulopathy (elevated D-dimers, fibrin). On average, the peak concentration of PCT was around 18 h and around 24 to 48 h for CRP. Increased PCT and CRP sends an alarm to physicians that patients should be in a later phase of sepsis compared to increased MDW. Biomarker measurement using a hematology analyzer has many advantages: (1) no requirement of additional blood collection for analysis in a clinical chemistry analyzer, (2) no time delay in obtaining the biomarker results along with routine CBC data, and (3) no large learning threshold for the interpretation of data. Moreover, recent studies have employed MDW to evaluate the severity of patients with coronavirus disease 2019 [29, 45, 46] . The cutoff values of the MDW were heterogenous among various studies, in which the reference interval for MDW was reported to be from 19 to 25 [9, 26, 42, 43, 47, 48] . Woo et al. indicated that the cutoff value of MDW of >19.8 demonstrated optimized sensitivity and specificity for screening patients with sepsis in the ED [26] . Crouser et al. revealed that an MDW of >20.5 differentiated patients with sepsis from those without sepsis in the ED setting [9] . Furthermore, Piva et al. showed that a MDW of >24.6 predicted sepsis in ICU patients according to Sepsis-3 criteria [48] . The cutoff value of >20.0 used for MDW in this study is consistent with that used in previous studies in the ED. The heterogeneity of the cutoff values of MDW might be relevant to the clinical stages of patients with sepsis. Compared with ICU patients, most patients admitted to the ED had the early stage of sepsis. This finding can explain the higher cutoff value of MDW in studies conducted in ICU patients than in those performed in ED patients. MDW outweighs other biomarkers examined using a hematology analyzer for early sepsis diagnosis in the ED, including the mean neutrophil volume, neutrophil distribution width, and mean monocyte volume [9] . Compared with MDW, these biomarkers exhibited delayed variations in response to sepsis [9] . Crouser et al. reported that the prediction performance for sepsis was more convincing when they used a combination of both MDW and WBC compared with MDW alone [9] . Besides, previous studies have found that NLR and PLR were significantly associated with the prediction and prognosis of sepsis [30, 31, [49] [50] [51] . Diordjevic et al. even noticed that level of NLR and PLR correlated with the results of blood culture [31] . The cutoff points of NLR [31, [52] [53] [54] [55] [56] [57] and PLR [31, 32, 56] varied among different studies. This variation could result from differences in the sepsis causes, the timeframe for examination, study participants, and test methods [30] . Our cutoff values are consistent with the reference intervals of NLR (ranging from 4.06 to 23.80) [31, [52] [53] [54] [55] [56] [57] and PLR (ranging from 200 to 240) [31, 32, 56] indicated in previous studies. Our findings indicated that NLR or PLR can be applied for early sepsis diagnosis. We attempted to improve the diagnostic performance for early sepsis recognition by combining biomarkers examined using a hematology analyzer and sepsis scoring systems. We observed that all sepsis scoring systems had a high specificity but low sensitivity, and biomarkers examined using a hematology analyzer had both moderate sensitivity and specificity ( Table 2 ). The biomarkers MDW, NLR, and PLR overcame the limitation of the low sensitivity of sepsis scoring systems (Table 3) . Multivariate models based on SIRS, SOFA, and qSOFA scores showed similar diagnostic performance for early sepsis diagnosis. Compared with the conventional biomarker CRP, our multivariate analysis performed using models with and without the inclusion of CRP showed similar diagnostic accuracy (the IDI test for c-statistics showed no significant difference, Table 3 ). This result suggested that the diagnostic performance of the new biomarkers was comparable to that of CRP. To simplify the complexity of early sepsis recognition in the ED, we developed a 5-point scoring system (Table 5 ) by combining qSOFA scores with MDW, NLR, and PLR. Our selection of the qSOFA score (rather than SIRS and SOFA scores) is reasonable because of the following reasons: (1) the qSOFA score assessed mental status, respiratory rate, and systolic blood pressure [12] ; thus, the qSOFA score is more convenient than SIRS and SOFA scores; (2) the diagnostic performance among SIRS, SOFA, and qSOFA scores was similar in multivariate models; and (3) a meta-analysis comparing clinical assessment tools for sepsis indicated that the SIRS score had higher sensitivity, whereas the qSOFA score had higher specificity [58] . Because our models focused on increasing specificity by using a sepsis scoring system, the qSOFA score was considered more optimal than the other two scores. Finally, the high specificity of the qSOFA score observed in our study is compatible with that indicated in a previous study [58] [59] [60] . We performed a separate secondary outcome to determine the prediction performance of these models for early mortality within 3 days. We observed that all these multivariate models combining sepsis scoring systems with biomarkers (Table 4 ) had high diagnostic performance. Of them, the model employing the SOFA score had the highest accuracy. We considered that the SOFA score offers more prognostic information than the other 2 scores, and this result is consistent with that reported by Raith [61] who assessed SIRS, SOFA, and qSOFA scores. In addition, the qSOFA score was more strongly correlated with unfavorable sepsis outcomes compared with the SIRS score. Moreover, clinical practice in the ED emphasizes early sepsis recognition more than prognostic information; therefore, the qSOFA score can be more optimal. In addition, Sepsis-2 criteria-based diagnosis is more applicable in the ED than Sepsis-3 criteria-based diagnosis [62] [63] [64] . We adopted Sepsis-2 definition to fulfill the real-world ED setting. For clinical use, we developed a tool that can diagnose sepsis in the early stages. In the present study, this new scoring system developed for predicting sepsis showed an AUC of 0.757 when a qSOFA score of >1, a NLR of >9 U, a PLR of >210, and a MDW of >20 U were employed. With a score of ≥2, this new scoring system showed good sensitivity and specificity for early identification of sepsis in the ED. The epidemiology of sepsis in the United States from Australasian resuscitation of sepsis evaluation (ARISE): A multi-centre, prospective, inception cohort study Rapid increase in hospitalization and mortality rates for severe sepsis in the United States: A trend analysis from 1993 to Assessment of the worldwide burden of critical illness: The intensive care over nations (ICON) audit Assessment of global incidence and mortality of hospital-treated sepsis. Current estimates and limitations Effects of sepsis and its treatment measures on intestinal flora structure in critical care patients Surviving the first hours in sepsis: Getting the basics right (an intensivist's perspective) Does Early and Appropriate Antibiotic Administration Improve Mortality in Emergency Department Patients with Severe Sepsis or Septic Shock? Improved Early Detection of Sepsis in the ED With a Novel Monocyte Distribution Width Biomarker ED Door-to-Antibiotic Time and Long-term Mortality in Sepsis Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis Assessment of clinical criteria for sepsis: For the Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3) The SOFA (Sepsis-Related Organ Failure Assessment) Score to Describe Organ Dysfunction/Failure The Third International Consensus Definitions for Sepsis and Septic Shock Monocyte distribution width as a biomarker of sepsis in the intensive care unit: A pilot study Improved Diagnostic and Prognostic Power of Combined Delta Neutrophil Index and Mean Platelet Volume in Pediatric Sepsis Diagnostic accuracy of procalcitonin, neutrophil-lymphocyte count ratio, C-reactive protein, and lactate in patients with suspected bacterial sepsis Use of procalcitonin for the prediction and treatment of acute bacterial infection in children Procalcitonin for guidance of antibiotic therapy Procalcitonin and C-reactive protein as markers of systemic inflammatory response syndrome severity in critically ill children Procalcitonin biomarker kinetics to predict multiorgan dysfunction syndrome in children with sepsis and systemic inflammatory response syndrome Procalcitonin does discriminate between sepsis and systemic inflammatory response syndrome Laboratory turnaround time A point-of-care chemistry test for reduction of turnaround and clinical decision time Use of point-of-care testing and early assessment model reduces length of stay for ambulatory patients in an emergency department. Scand Monocyte distribution width compared with C-reactive protein and procalcitonin for early sepsis detection in the emergency department Neutrophil swarms require LTB4 and integrins at sites of cell death in vivo Neutrophil migration in inflammation: Intercellular signal relay and crosstalk Clinical impact of monocyte distribution width and neutrophil-to-lymphocyte ratio for distinguishing COVID-19 and influenza from other upper respiratory tract infections: A pilot study Prognostic value of neutrophil-to-lymphocyte ratio in sepsis: A meta-analysis Neutrophil-to-lymphocyte ratio, monocyte-to-lymphocyte ratio, platelet-to-lymphocyte ratio, and mean platelet volume-to-platelet count ratio as biomarkers in critically ill and injured patients: Which ratio to choose to predict outcome and nature of bacteremia? Platelet-to-lymphocyte ratio as a prognostic predictor of mortality for sepsis: Interaction effect with disease severity-a retrospective study Platelet to lymphocyte ratio in neonates: A predictor of early onset neonatal sepsis Novel metrics for evaluating improvement in discrimination: Net reclassification and integrated discrimination improvement for normal variables and nested models Surviving Sepsis Campaign: International guidelines for management of severe sepsis and septic shock Effectiveness of treatments for severe sepsis: A prospective, multicenter, observational study Influence of antibiotic therapy on mortality of critical surgical illness caused or complicated by infection Impact of the Surviving Sepsis Campaign protocols on hospital length of stay and mortality in septic shock patients: Results of a three-year follow-up quasi-experimental study Cl-channels are expressed in human normal monocytes: A functional role in migration, adhesion and volume change Morphological evaluation of monocytes and their precursors Monocyte subsets are differentially lost from the circulation during acute inflammation induced by human experimental endotoxemia Monocyte distribution width (MDW) as a screening tool for sepsis in the Emergency Department Monocyte distribution width enhances early sepsis detection in the emergency department beyond SIRS and qSOFA Monocyte Distribution Width: A Novel Indicator of Sepsis-2 and Sepsis-3 in High-Risk Emergency Department Patients Elevated monocyte distribution width in COVID-19 patients: The contribution of the novel sepsis indicator Mild versus severe COVID-19: Laboratory markers Comparison of Monocyte Distribution Width (MDW) and Procalcitonin for early recognition of sepsis Monocyte distribution width (MDW) parameter as a sepsis indicator in intensive care units Neutrophil to lymphocyte ratio (NLR) as a prognostic marker for in-hospital mortality of patients with sepsis: A secondary analysis based on a single-center, retrospective, cohort study Early blood biomarkers to improve sepsis/bacteremia diagnostics in pediatric emergency settings An investigation of the effects of the mean platelet volume, platelet distribution width, platelet/lymphocyte ratio, and platelet counts on mortality in patents with sepsis who applied to the emergency department Prognostic significance of neutrophil-to-lymphocyte ratio in patients with sepsis: A prospective observational study Neutrophil-to-lymphocyte ratio as a feasible prognostic marker for pyogenic liver abscess in the emergency department Evaluation value of dynamic monitoring of neutrophil/lymphocyte ratio in peripheral blood in severity of illness and prognosis of bacterial sepsis Value of neutrophil to lymphocyte ratio in predicting the prognosis of patients with sepsis Prognostic value of an inflammatory biomarker-based clinical algorithm in septic patients in the emergency department: An observational study Neutrophil-to-lymphocyte ratio as a predictive marker for severe pediatric sepsis Head-to-head comparison of qSOFA and SIRS criteria in predicting the mortality of infected patients in the emergency department: A meta-analysis. Scand SIRS or qSOFA? Is that the question? Clinical and methodological observations from a meta-analysis and critical review on the prognostication of patients with suspected sepsis outside the ICU Quick sequential organ failure assessment as a prognostic factor for infected patients outside the intensive care unit: A systematic review and meta-analysis Prognostic accuracy of the SOFA score, SIRS criteria, and qSOFA score for in-hospital mortality among adults with suspected infection admitted to the intensive care unit Comparison of QSOFA score and SIRS criteria as screening mechanisms for emergency department sepsis The SIRS criteria have better performance for predicting infection than qSOFA scores in the emergency department Poor performance of quick-SOFA (qSOFA) score in predicting severe sepsis and mortality-a prospective study of patients admitted with infection to the emergency department